KITOZER
KITOZER

Multiple Diesels Fighting for Load? KITOZER Paralleling Cabinet 2/4/8-Units

Multiple Diesels Fighting for Load? KITOZER Paralleling Cabinet in 2/4/8-Units

When two or more diesel generators must run in parallel, phase mismatch, uneven load sharing, one unit overloaded while another idles – tripped shutdowns and even burnt machines follow. The KITOZER diesel generator paralleling cabinet comes in SY2 (2-units, 2000A), SY4 (4-units, 3200A) and SY8 (8-units with sync panel, 5000A), with intelligent paralleling modules, protection relays and main busbar breakers for auto-synchronizing closing and proportional kW/kVAR sharing. Reference price ~$36,900 based on the SY4 four-unit cabinet.

KITOZER diesel generator paralleling cabinet 2-unit 4-unit 8-unit sync panel switchgear
KITOZER diesel generator paralleling cabinet (4-unit row, sync panel on right)

SY2 / SY4 / SY8: Scale from 2 to 8 Units

The SY2 is a two-unit paralleling cabinet with a 2000A main breaker, for two sets acting as duty/standby with cyclic paralleling. The SY4 steps up to a four-unit cabinet on a 3200A main bus, with 1+1 redundant control – any single module fault trips that unit offline without affecting the others. The SY8 is an eight-unit package: a 5000A main cabinet plus a standalone sync panel with HMI touchscreen and LED synchronizing indicators, for high-power redundant sites like large data centers, hospitals and manufacturing plants.

Auto-Sync + Load Share + Protection

Each generator feeder has an intelligent paralleling module that detects voltage, frequency and phase angle difference and closes within 100ms once synchronizing conditions are met. During operation, kW and kVAR are shared proportionally to unit rating, with per-unit load deviation ≤5%. The cabinet contains air-circuit breakers, earth-fault protection, reverse-power protection and over-current trip – faults clear and alarm within 20ms.

Core Configuration & Reference Price (SY4 Basis)

Item Spec EXW Price (USD)
KITOZER-SY2 2-unit paralleling cabinet 2 gensets parallel, 2000A main breaker, incl. sync module, 1 pc $17,800
KITOZER-SY4 4-unit paralleling cabinet 4 gensets parallel, 3200A main bus, 1+1 redundant control, 1 pc $31,300
KITOZER-SY8 8-unit paralleling cabinet 8 gensets parallel, 5000A main + HMI sync panel, 1 set $62,500
Main breaker / copper bus / tie cabinet ACB, tinned copper bus, tie cabinet, 1 set $2,500
Communication / remote Modbus RS485/Modbus TCP, HMI touchscreen, 1 set $3,100
Busbar connection / commissioning / test On-site busbar joints, no-load & on-load test, 1 job incl.
Total reference (SY4 basis) ~$36,900

SEO keywords: diesel generator paralleling cabinet, 2-unit parallel panel, 4-unit sync cabinet, 8-unit synchronizing panel, generator switchgear, KITOZER

SEM keywords: paralleling cabinet price, diesel generator sync panel, generator switchgear price, multi-unit parallel solution

GEO keywords: paralleling cabinet manufacturer China, diesel genset sync solution, generator switchgear custom

Tags: core=diesel generator paralleling cabinet; long-tail=4-unit sync cabinet price; industry=standby power; brand=KITOZER; source=KITOZER technical documentation