Chapter 1 Product Introduction

1.1 Product Definition and Overview

The Network Traffic Analysis Device (hereinafter referred to as NTA Device) is the core infrastructure in modern enterprise network operations management, security situational awareness, and performance optimization systems. Through multiple technical approaches such as bypass mirroring, optical splitting acquisition, and flow protocol export, the device performs real-time capture, deep parsing, intelligent modeling, and visualized presentation of full-volume or sampled data flows transmitted over the network, achieving full-dimensional traffic transparency from the physical layer to the application layer. It provides data support and decision-making basis for network bandwidth planning, rapid fault localization, security threat detection, business quality assessment, and compliance auditing.

The LA-NTA series network traffic analysis devices, independently developed by Guangzhou Lain Intelligent System Development Co., Ltd., employ a high-performance processing engine combining FPGA hardware acceleration architecture with the DPDK (Data Plane Development Kit). They support GE/10GE/25GE/40GE/100GE full-rate interface adaptation, featuring wire-speed traffic capture, seven-layer protocol deep parsing, full-traffic retrospective storage, intelligent anomaly detection, and multi-dimensional visualized analysis capabilities. These devices are widely applicable to government, financial, telecom operator, education, healthcare, energy, and enterprise data center network environments, serving as key supporting equipment for building intelligent, visualized, and traceable network management systems.

1.2 Product Development Background and Industry Value

With the deepening advancement of the digital economy, enterprise network architectures have become increasingly complex. New forms such as hybrid cloud, multi-cloud deployment, SD-WAN wide-area interconnection, and IoT terminal access continue to emerge. Network traffic exhibits notable characteristics including rapid bandwidth growth, a wide variety of protocols, an increasing proportion of encrypted traffic, and increasingly concealed attack methods. Traditional SNMP-based port-level monitoring can only obtain macroscopic indicators such as bandwidth utilization, cannot penetrate to the session level to locate performance bottlenecks, and struggles to identify security threats hidden within legitimate traffic. This approach can no longer meet the demands of modern network refined operations and security protection.

Against this backdrop, network traffic analysis devices, leveraging their core advantages of “full-volume acquisition, deep parsing, retrospective forensics, and intelligent analysis,” have gradually become standard equipment in the network management field. Their industry value is primarily reflected in the following dimensions:

  • Operations Efficiency Improvement: Reduces average network fault troubleshooting time from hours to minutes, rapidly locating root causes through traffic retrospective analysis, thereby reducing business interruption losses.
  • Bandwidth Resource Optimization: Precisely identifies traffic proportions of various applications, departments, and links, providing data support for bandwidth expansion and QoS policy formulation, while reducing IT investment costs.
  • Security Posture Enhancement: Detects abnormal access, data exfiltration, lateral movement, and other attack behaviors based on traffic behavior baselines, complementing the deficiencies of traditional perimeter defense equipment and building a defense-in-depth system.
  • Compliance Audit Satisfaction: Retains full-volume network access logs and raw packets, meeting compliance requirements of Multi-Level Protection Scheme 2.0, the Data Security Law, and industry regulations, while providing electronic evidence for security incident traceability.
  • Business Quality Assurance: By parsing transaction traffic of core business systems, quantitatively evaluates key indicators such as business response latency, success rate, and packet loss rate, ensuring stable operation of critical business services.

1.3 Product Implementation Standards

The design, production, inspection, and delivery of this product strictly comply with the following national and industry standards:

  • GB/T 28181-2022 “Technical Requirements for Information Transmission, Exchange, and Control of Public Security Video Surveillance Networking System”
  • GB/T 22239-2019 “Information Security Technology — Baseline for Classified Protection of Cybersecurity”
  • GB/T 25069-2022 “Information Security Technology — Terminology”
  • YD/T 3745-2020 “Technical Requirements for IP Network Traffic Analysis Equipment”
  • RFC 3954 “Cisco Systems NetFlow Services Export Version 9”
  • RFC 7011 “Specification of the IP Flow Information Export (IPFIX) Protocol”
  • RFC 3176 “InMon Corporation’s sFlow: A Method for Monitoring Traffic in Switched and Routed Networks”
  • IEEE 802.3 Series Ethernet Standards

1.4 Product Model Naming Convention

The LA-NTA series network traffic analysis devices adopt a unified model naming system, enabling users to quickly identify product specifications and positioning. The naming convention is as follows:

LA - NTA - XXXX - Y - Z
│     │      │    │   │
│     │      │    │   └── Storage Capacity Identifier: T1(1TB), T2(2TB), T4(4TB), T8(8TB), T16(16TB), T32(32TB)
│     │      │    └────── Deployment Form: R(Rack-mount), E(Embedded), D(Desktop), B(Blade)
│     │      └────────── Processing Capability Level: 1000(1Gbps), 10000(10Gbps), 40000(40Gbps), 100000(100Gbps)
│     └───────────────── Product Series Code: NTA represents the Network Traffic Analysis series
└─────────────────────── Brand Code: LA represents Lain

Example: LA-NTA-10000-R-T8 represents a Lain brand NTA series network traffic analysis device with 10Gbps processing capability, rack-mount form factor, and 8TB storage capacity.

Chapter 2 Product Composition

2.1 Hardware System Composition

The LA-NTA series network traffic analysis devices adopt a modular hardware architecture design, primarily consisting of six core units: traffic acquisition module, data processing module, storage module, management interface module, power supply module, and thermal dissipation module. Each unit operates cooperatively through high-speed internal buses, ensuring high performance and high reliability of the entire system.

2.1.1 Traffic Acquisition Module

The traffic acquisition module serves as the input front-end of the device, responsible for completing the access, optical-electrical conversion, and preprocessing of raw network traffic. This module uses a programmable FPGA chip as the core processing unit, supporting wire-speed traffic reception and preprocessing operations. It primarily includes the following sub-components:

  • Optical/Electrical Physical Interfaces: Provides multiple interface forms including SFP, SFP+, SFP28, QSFP+, and QSFP28, supporting 10/100/1000BASE-T electrical ports and optical port adaptation for 100BASE-FX, 1000BASE-LX/SX, 10GBASE-LR/SR/ER, 40GBASE-LR4/SR4, and 100GBASE-LR4/SR4, with optical modules flexibly selectable based on the user’s actual link type.
  • FPGA Preprocessing Engine: Completes basic processing at the hardware level including packet timestamp tagging, packet truncation, traffic deduplication, VLAN tag stripping, MPLS label parsing, and five-tuple filtering, reducing the processing pressure on the backend CPU and ensuring zero packet loss capture at high bandwidth.
  • Clock Synchronization Unit: Supports the IEEE 1588 PTP (Precision Time Protocol) and NTP (Network Time Protocol), providing nanosecond-level high-precision timestamps and establishing a unified time reference for multi-device distributed deployment and cross-link latency measurement.
  • Traffic Aggregation and Distribution Unit: Supports aggregation and merging of multiple input traffic flows as well as replication and distribution, enabling the same traffic mirror to be output to multiple backend analysis devices simultaneously, meeting the parallel analysis requirements of multiple systems.

2.1.2 Data Processing Module

The data processing module is the core computing unit of the device, responsible for completing core algorithmic operations including protocol parsing, traffic statistics, behavior analysis, and threat detection. This module adopts a heterogeneous computing architecture of “multi-core CPU + dedicated coprocessors,” balancing high performance and flexibility:

  • Multi-core CPU Processor: Utilizes high-end domestic multi-core processors or Intel Xeon series processors with 16 to 64 cores, clock speeds above 2.0GHz, and large-capacity L3 cache, responsible for general computing tasks such as deep protocol parsing, session management, statistical computation, and web services.
  • DPDK Acceleration Engine: Implements kernel bypass and zero-copy technology based on the Data Plane Development Kit, bypassing the traditional operating system kernel protocol stack and directly completing packet transmission/reception and processing in user space, significantly improving packet forwarding and processing performance while reducing processing latency.
  • DPI Deep Packet Inspection Coprocessor: Integrates a dedicated protocol recognition acceleration chip, equipped with a feature library of over 3,000 application protocols, supporting rapid identification and classification of application-layer protocols with processing performance far exceeding pure software implementations.
  • Memory Subsystem: Configured with 32GB to 512GB of DDR4/DDR5 high-speed memory with ECC error correction mechanisms, divided into packet buffer area, session table area, statistical data area, and system operation area, ensuring system stability under high-traffic impact.

2.1.3 Storage Module

The storage module is responsible for persistent storage of raw packets, flow records, statistical data, system logs, and alarm information, forming the foundation for traffic retrospective analysis and historical analysis. Based on different product positioning, a tiered storage architecture is adopted:

  • High-speed Cache Layer: Utilizes NVMe SSD solid-state drives with capacities of 1TB to 8TB, used for storing real-time traffic data and frequently accessed statistical reports, providing extremely high read/write performance and ensuring real-time analysis response speed.
  • Large-capacity Storage Layer: Utilizes enterprise-grade SATA HDD mechanical hard drives or large-capacity SSDs with capacities of 4TB to 128TB, supporting RAID 0/1/5/6/10 multiple redundancy modes, used for long-term retention of raw packets and historical statistical data, with storage periods flexibly configurable based on user requirements.
  • Storage Management Engine: Integrates intelligent storage management software supporting circular overwrite storage, on-demand retention, critical data locking, storage capacity warning, and data backup export functions, ensuring efficient and reliable storage system operation.
  • Data Export Interface: Supports USB 3.0, eSATA, and other external storage interfaces, enabling export of traffic data from specified time periods to external storage media for offline analysis and data archiving.

2.1.4 Management Interface Module

The management interface module is responsible for device configuration management, data output, and alarm linkage, providing multiple management channels to meet different operations scenario requirements:

  • Console Management Port: RJ45 serial port with a default baud rate of 9600bps, supporting CLI (Command Line Interface) configuration for device initial configuration and emergency fault management.
  • ETH Management Port: Independent 10/100/1000BASE-T Ethernet management interface, physically isolated from business acquisition ports to ensure management channel security, used for web management, SSH remote login, SNMP management, and log reporting.
  • Alarm Output Interface: Provides relay dry contact alarm output and audible/visual alarm interfaces, connectable to data center environment monitoring systems for physical alarming of critical events such as device hardware faults, port anomalies, and storage full conditions.
  • Expansion Interfaces: Reserved PCIe expansion slots and USB interfaces for expanding functional components such as wireless management modules, 4G/5G remote operations modules, and encryption cards.

2.1.5 Power Supply and Thermal Dissipation Module

  • Power Supply Module: Rack-mount models come standard with 1+1 redundant AC power supplies, supporting wide-range input voltage of AC 100~240V 50/60Hz. Certain high-end models support DC power input and dual-path power seamless switching. Power conversion efficiency exceeds 92%, compliant with 80PLUS Platinum certification standards.
  • Thermal Dissipation Module: Adopts an intelligent temperature-controlled fan cooling system that automatically adjusts fan speed based on internal device temperature, reducing operating noise and energy consumption while ensuring cooling effectiveness. Critical chips are equipped with independent heat sinks and heat pipes to ensure stable operation under high loads.
  • Environmental Monitoring Unit: Real-time monitoring of internal device temperature, voltage, fan speed, and power supply status parameters, automatically triggering alarms and protection mechanisms upon anomalies.

2.2 Software System Composition

The LA-NTA series devices are equipped with the independently developed LA-OS network traffic analysis operating system, adopting a modular software architecture divided into four layers: system platform layer, data processing layer, business function layer, and interactive presentation layer. Each layer interacts through standardized interfaces, providing excellent scalability and maintainability.

2.2.1 System Platform Layer

The system platform layer serves as the operating foundation of the entire software system, providing hardware drivers, operating system kernel, basic services, and security protection capabilities:

  • Customized Linux Kernel: Based on a stable version of the Linux kernel with deep tailoring and optimization, removing unnecessary system services and tuning kernel parameters for network packet processing to enhance system real-time performance and stability.
  • Hardware Device Drivers: Provides comprehensive hardware driver support for FPGA acquisition cards, network interface cards, storage controllers, and power management, enabling unified scheduling and management of hardware resources.
  • Basic Service Components: Includes web services, database services, time synchronization services, logging services, and user authentication services, providing operational support for upper-layer applications.
  • System Security Protection: Built-in firewall, access control, operation auditing, and data encryption security mechanisms, ensuring the device’s own operational security and data security.

2.2.2 Data Processing Layer

The data processing layer is the core functional layer of the software system, responsible for completing the full-process processing from raw packets to structured analysis data, including the following core engines:

  • Packet Capture Engine: Supports multiple data access methods including mirror port capture, TAP split capture, and NetFlow/sFlow/IPFIX flow collection, normalizing data formats before sending to subsequent processing pipelines.
  • Protocol Parsing Engine: Supports full protocol stack parsing from Layer 2 to Layer 7, capable of identifying over 5,000 network protocols and applications, including traditional Internet protocols, industrial control protocols, audio/video protocols, database protocols, and cloud service protocols, with support for online protocol feature library upgrades.
  • Traffic Statistics Engine: Performs session aggregation statistics based on five-tuple and seven-tuple identifiers, real-time calculation of over a hundred performance indicators including bandwidth, rate, packet count, connection count, latency, and packet loss rate, supporting multi-dimensional aggregate statistics.
  • Behavior Analysis Engine: Establishes normal traffic behavior baselines based on machine learning algorithms, real-time detection of anomalous traffic behaviors deviating from baselines, and identification of security threats including port scanning, DDoS attacks, data exfiltration, and anomalous external connections.
  • Data Storage Engine: Combines time-series databases with file storage, separately handling structured statistical data and unstructured raw packets, achieving high-performance writes and rapid retrieval.

2.2.3 Business Function Layer

The business function layer provides various user-scenario-oriented business function modules based on the output results of the data processing layer:

  • Real-time Monitoring Module: Provides full-network traffic real-time situational display, link utilization monitoring, top traffic rankings, and real-time anomaly alarm display functions.
  • Retrospective Analysis Module: Supports multi-dimensional combined retrieval of historical traffic data by time, IP, port, protocol, and application, capable of reconstructing original session processes and supporting packet-level deep analysis.
  • Performance Analysis Module: Provides performance indicator analysis for network links, business systems, and critical hosts, quantitatively assessing network quality and business service quality.
  • Security Analysis Module: Provides security operations functions including threat detection, attack traceability, anomalous behavior analysis, and security situational assessment.
  • Report Management Module: Includes a rich library of built-in statistical report templates, supporting automatic generation and export of daily, weekly, monthly, and annual reports, as well as custom reports.
  • System Management Module: Provides system management functions including device configuration, user management, permission assignment, system upgrades, data backup, and log auditing.

2.2.4 Interactive Presentation Layer

The interactive presentation layer serves as the interface for user-device interaction, providing multiple access methods and visual presentations:

  • Web Management Interface: Adopts a B/S architecture, accessible via standard browsers without client installation requirements. The interface uses responsive design, adapting to computers, tablets, and other terminals.
  • Visualization Dashboard: Provides command center large-screen display mode, intuitively presenting full-network traffic situational awareness through multiple forms including topology maps, heat maps, trend charts, and dashboards.
  • Command Line Interface: Supports SSH and Console command line management, meeting the efficient configuration requirements of professional operations personnel.
  • Northbound Interfaces: Provides standardized northbound interfaces including RESTful API, Syslog, SNMP, and Kafka, supporting seamless integration with third-party operations platforms, security platforms, and big data platforms.

Chapter 3 Product Classification

3.1 Classification by Technical Approach

Based on differences in traffic acquisition granularity and core technical approaches, the LA-NTA series network traffic analysis devices are divided into four major categories, corresponding to different application requirements and cost budgets. Users can select the appropriate model based on their actual scenarios.

3.1.1 Flow Statistical Analysis Type (Basic NTA)

Flow statistical analysis type devices perform data collection based on standard flow protocols such as NetFlow, sFlow, IPFIX, and NetStream. Network devices proactively export traffic metadata, and the device only receives and analyzes flow records without collecting raw packets.

  • Technical Principle: Network devices (routers, switches, firewalls, etc.) sample packets passing through according to fixed sampling ratios, generating flow records containing fields such as source IP, destination IP, source port, destination port, protocol type, packet count, byte count, start/end time, and sending them to the traffic analysis device via UDP protocol. The device aggregates, statistically processes, and visualizes the flow records.
  • Core Advantages: Simple deployment without network topology changes; extremely low device performance overhead with a single device capable of managing hundreds of network devices; low storage costs requiring only structured flow data; supports large-scale WAN distributed deployment.
  • Capability Limitations: Can only provide macroscopic traffic statistical views without packet-level deep analysis capability; fault localization granularity is relatively coarse and cannot identify root causes; no raw packet retention, lacking support for security event retrospective forensics; small traffic attacks may be missed under sampling mode.
  • Applicable Scenarios: Macroscopic operations scenarios with low analysis granularity requirements, including large enterprise full-network bandwidth monitoring, multi-branch traffic statistics, link capacity planning, QoS policy verification, and basic anomalous traffic alarming.

3.1.2 Full Traffic Deep Analysis Type (Advanced NTA/NDR)

Full traffic deep analysis type devices collect full-volume raw packets from links via bypass mirroring or optical splitting, completing packet storage, deep protocol parsing, session-level performance analysis, and security threat detection. This is the current mainstream high-end traffic analysis device form.

  • Technical Principle: Link traffic is replicated through switch mirror ports or independent optical splitters and sent to the analysis device. The device performs wire-speed capture and timestamp tagging on all raw packets, extracts session information and performance indicators after DPI deep parsing, and simultaneously writes raw packets to the storage system, supporting post-hoc retrospective analysis.
  • Core Advantages: Fine analysis granularity reaching packet level; supports full protocol deep parsing and application identification; complete traffic retrospective capability enabling reconstruction of network communication processes at any historical moment; precise fault localization directly identifying the location and cause of packet loss, latency, and retransmission issues; strong security detection capability identifying various concealed attack behaviors.
  • Capability Limitations: Higher equipment costs with demanding hardware performance requirements; large storage capacity requirements as full-volume raw packet retention generates significant storage overhead; deployment requires planning of mirror or split points with some network topology modification.
  • Applicable Scenarios: Scenarios requiring high analysis depth, including data center core link monitoring, critical business system performance analysis, security event traceability and forensics, complex network fault troubleshooting, and compliance auditing.

3.1.3 Hybrid Acquisition Analysis Type

Hybrid acquisition analysis type devices simultaneously support both flow protocol acquisition and full traffic acquisition modes, allowing flexible selection of acquisition methods based on the importance of different links, balancing full-network coverage with focused deep analysis. This is the preferred solution for medium and large networks.

  • Technical Principle: For non-core links such as WAN links and branch access links, NetFlow/sFlow flow acquisition mode is adopted for cost-effective full coverage; for critical nodes such as data center core links and business server areas, full traffic mirror acquisition is used for deep analysis; both data types are uniformly presented and correlated at the platform level.
  • Core Advantages: Optimal cost-effectiveness, achieving a balance between full-network visibility and focused deep analysis within limited budgets; flexible deployment with dynamic adjustment of acquisition strategies based on business changes; complementary data combining macroscopic statistics with microscopic analysis.
  • Applicable Scenarios: Scenarios requiring both full-network coverage and focused deep monitoring, including medium and large enterprise tiered networks, multi-region distributed networks, and cloud-premises hybrid architecture networks.

3.1.4 Embedded Probe Type

Embedded probe type devices adopt miniaturized, low-power design, deployed at various network branch nodes or remote sites, responsible for local traffic acquisition and preliminary processing, reporting analysis results or sampled data to the central analysis platform. Suitable for distributed networking scenarios.

  • Technical Principle: Probe devices are deployed at each branch node, performing local traffic acquisition, preliminary parsing, and data compression locally, reporting metadata to the headquarters central platform via WAN, where the central platform performs unified aggregation analysis and visual presentation. When necessary, raw packets at the probe end can be remotely retrieved for deep analysis.
  • Core Advantages: Distributed deployment close to data sources, reducing WAN bandwidth consumption; compact probe size and low power consumption suitable for branch sites with limited equipment room conditions; centralized management with high operations efficiency.
  • Applicable Scenarios: Wide-area distributed scenarios including chain stores, multiple branch offices, campus distributed networks, and industrial site distributed nodes.

3.2 Classification by Deployment Form

3.2.1 Rack-mount Devices

Rack-mount devices adopt standard 19-inch rack installation structures with heights of 1U, 2U, and 4U, representing the mainstream deployment form in data centers and core equipment rooms.

  • Structural Characteristics: Standard rack installation with L-type mounting brackets and cage nuts; front panel provides status indicator lights, control buttons, and interfaces; rear panel houses business interfaces, management interfaces, and power interfaces; internal modular layout facilitates maintenance and expansion.
  • Performance Positioning: Mid-to-high-end performance, supporting high-bandwidth processing and large-capacity storage, meeting core link analysis requirements.
  • Applicable Environments: Environments with standard cabinets, including standard data center equipment rooms, core equipment rooms, and telecom operator equipment rooms.

3.2.2 Desktop Devices

Desktop devices adopt compact body design with small form factors, directly placeable on desktops or workbenches without requiring cabinet installation.

  • Structural Characteristics: Integrated body with built-in power adapter; silent fan design suitable for office environments; front-panel interfaces for easy operation.
  • Performance Positioning: Entry-level to mid-range performance, with processing capabilities ranging from 1Gbps to 10Gbps and relatively smaller storage capacities.
  • Applicable Environments: Environments without standard cabinets, including small and medium enterprise equipment rooms, offices, small branch sites, and laboratories.

3.2.3 Blade Devices

Blade devices adopt blade server architecture, inserted into standard blade chassis, sharing the chassis’s power, cooling, management, and switching resources.

  • Structural Characteristics: High-density deployment with multiple traffic analysis blades insertable into a single chassis; unified management with centralized power and cooling; high-speed backplane interconnection enabling convenient data exchange between blades.
  • Performance Positioning: High-end performance with horizontally expandable processing capability and storage capacity.
  • Applicable Environments: High-density deployment environments adopting blade server architecture, including large cloud computing centers and telecom operator core equipment rooms.

3.2.4 Embedded Devices

Embedded devices adopt industrial-grade embedded hardware design with fanless or low-power cooling, wide temperature and voltage adaptation, suitable for industrial sites and harsh environment deployment.

  • Structural Characteristics: DIN rail or wall-mount installation; metal housing with protection rating of IP40 or above; wide temperature operating range of -20°C to 60°C; wide voltage power input of DC 12~48V.
  • Performance Positioning: Mid-range performance, meeting industrial network and edge node traffic analysis requirements.
  • Applicable Environments: Scenarios with relatively harsh environmental conditions, including industrial control networks, intelligent transportation, smart cities, and outdoor cabinets.

3.3 Classification by Business Focus

3.3.1 Operations Performance Type

Operations performance type products focus on network performance monitoring and fault troubleshooting functions, with core indicators focusing on network performance dimensions such as bandwidth utilization, latency, packet loss, retransmission, and connection count, helping operations teams quickly identify and resolve network performance issues.

  • Core Functions: Real-time bandwidth monitoring, link quality analysis, TCP performance analysis, application response time analysis, business quality assessment, and fault localization diagnostics.
  • Target Users: Enterprise network operations teams, IDC operations departments, and telecom operator network departments.

3.3.2 Security Analysis Type

Security analysis type products focus on network security threat detection and traceability forensics, with core capabilities focusing on anomalous behavior detection, attack identification, threat hunting, and event retrospective analysis, serving as important technical support for security operations centers.

  • Core Functions: Anomalous traffic detection, attack behavior identification, threat intelligence matching, lateral movement detection, data exfiltration monitoring, full traffic retrospective forensics, and attack path reconstruction.
  • Target Users: Enterprise security teams, SOC (Security Operations Center), and organizations building MLPS compliance systems.

3.3.3 Comprehensive All-round Type

Comprehensive all-round type products fully cover both operations performance and security analysis domains, while also possessing powerful reporting and northbound interface capabilities, simultaneously meeting the dual requirements of both network departments and security departments, achieving multiple purposes with a single device.

  • Core Functions: Combines all functions of both operations performance analysis and security analysis, supports multi-tenancy and multi-role permission management, and provides rich northbound interfaces and customization capabilities.
  • Target Users: Organizations with simultaneous operations and security requirements, including medium and large enterprises, government agencies, universities, and hospitals.

Chapter 4 Product List

4.1 Standard Packing List

When the LA-NTA series network traffic analysis device leaves the factory, the standard packaging box contains the following items. After opening the box, users should verify each item against the table below. If any items are missing or damaged, please contact the supplier promptly.

No. Item Name Quantity Remarks
1 Network Traffic Analysis Device Main Unit 1 unit Specific model per contract and product nameplate
2 AC Power Cord 1~2 pcs Rack-mount redundant power models include 2 cords; desktop models include 1 cord; length 1.8 meters
3 Console Configuration Cable 1 pc RJ45 to RJ45 serial cable, length 1.5 meters
4 L-type Mounting Bracket 1 pair Standard for rack-mount models, includes matching mounting screws
5 Cage Nuts 1 set 4 sets total, used for cabinet installation fixing
6 Product Certificate of Conformity 1 copy Stamped with quality inspection qualification seal
7 Product User Manual 1 copy Paper version, this manual
8 Warranty Card 1 copy Contains product information and warranty terms
9 Desiccant 1 bag For moisture protection during transportation

4.2 Optional Accessories List

The following are optional accessories that users can purchase separately based on actual requirements:

No. Accessory Name Specification/Model Applicable Scenario
1 Optical Module SFP+ 10G LR 10km Long-distance fiber optic link access
2 Optical Module SFP+ 10G SR 300m Short-distance multimode fiber optic link access
3 Optical Splitter 1-to-2 Single-mode, Splitting Ratio 50:50 Fiber link bypass acquisition without affecting the original link
4 Optical Splitter 1-to-2 Single-mode, Splitting Ratio 70:30 Lower main path loss, suitable for long-distance links
5 Network Cable Category 6 Shielded, 3 meters Electrical port link connection
6 Fiber Patch Cord LC-LC Single-mode, 3 meters Optical port link connection
7 Redundant Power Module AC Redundant Power Supply Backup power for device expansion
8 Hard Drive Expansion Module 4TB/8TB Enterprise-grade HDD Expanding storage capacity
9 4G Remote Operations Module Full-Network 4G Module Remote management in environments without external network access
10 Rack Rails 19-inch Standard Rails Replacement for L-type brackets, higher load-bearing capacity

4.3 Documentation List

The technical documentation included with the device contains the following materials, serving as important references for device installation, commissioning, usage, and maintenance:

  • Network Traffic Analysis Device Installation, Wiring, and Commissioning Manual (this document): Detailed introduction to product principles, installation, wiring, commissioning, operation, maintenance, and fault handling.
  • Product Certificate of Conformity: Certifies that the product has passed inspection and conforms to factory standards.
  • Warranty Card: Specifies warranty period, coverage, procedures, and service contact information.
  • Packing List: Itemizes all contents within the box.
  • Software License: Specifies software license period, functional module authorization, and node authorization quantity.

4.4 Acceptance and Verification Notes

  • Before opening the box, inspect the packaging exterior for integrity, checking for obvious signs of impact damage, water intrusion, or deformation. If anomalies are found, take photos for documentation and contact the logistics provider and supplier.
  • When opening the box, carefully preserve the packaging materials for future use during device return for repair or relocation.
  • Verify items one by one against the packing list, confirming that the device model and serial number match the contract.
  • Inspect the device exterior for scratches, deformation, loose screws, or other physical damage, and check interfaces for foreign objects or damage.
  • After verification, complete the arrival confirmation form. If any items are missing or damaged, provide written feedback to our company within three working days.

Chapter 5 Product Principles

5.1 Basic Principles of Traffic Acquisition

Traffic acquisition is the foundation of network traffic analysis. Its core objective is to completely and accurately obtain the network traffic data requiring analysis without affecting the normal operation of the existing network. The LA-NTA device supports three mainstream acquisition methods, each suited to different link types and scenario requirements.

5.1.1 Port Mirroring Acquisition Principle

Port Mirroring, also known as port monitoring or SPAN (Switched Port Analyzer), is a standard switch function. It works by replicating traffic from one or more source ports and forwarding it to a designated destination mirror port, then connecting the mirror port to the traffic analysis device to achieve traffic acquisition.

Working Process:

1. Configure mirror sources on the switch. Physical ports, VLANs, and aggregate ports can be selected as mirror sources, supporting ingress direction, egress direction, or bidirectional traffic mirroring.

2. Configure the mirror destination port, which is dedicated solely to outputting mirrored traffic and does not carry normal business data.

3. The switch’s internal switching chip replicates all packets from source ports and forwards them through the backplane to the destination mirror port.

4. The traffic analysis device connects to the mirror destination port, receiving and analyzing the replicated traffic.

Technical Characteristics:

  • Pure software configuration, no additional hardware investment required, low cost
  • Flexible deployment with the ability to adjust mirror sources and mirror directions at any time
  • Limited by switch chip performance; mirror packet loss may occur at high bandwidth
  • Occupies switch business port resources

Applicable Scenarios:

  • Enterprise networks with sufficient switch port resources
  • Gigabit and below low-speed links
  • Temporary testing and fault troubleshooting scenarios

5.1.2 Optical Splitter Acquisition Principle

Optical splitter acquisition is the standard acquisition method for fiber optic links. By inserting a passive optical splitter into the fiber link, the optical signal is divided into two paths according to a ratio — one path continues transmission to the original receiving end to ensure normal business operation, while the other path is connected to the traffic analysis device.

Working Process:

1. Disconnect the original fiber link and connect the transmitting-end fiber to the splitter’s input port.

2. Connect the splitter’s main output fiber to the original receiving device to ensure normal business traffic transmission.

3. Connect the splitter’s branch output fiber to the optical port of the traffic analysis device.

4. After passing through the splitter, the optical signal is distributed according to a fixed ratio — the main path retains the majority of optical power for business, while the branch path retains a smaller portion for analysis.

Split Ratio Selection:

  • 50:50 Split Ratio: Main path and branch path each receive half the optical power. Acquisition signal quality is excellent, but the loss to the original link is greater. Suitable for short-distance links with sufficient optical power margin.
  • 70:30 Split Ratio: Main path 70%, branch path 30%. Less impact on the original link with acceptable acquisition signal quality. This is the most commonly used ratio.
  • 90:10 Split Ratio: Main path 90%, branch path 10%. Minimal impact on the original link. Suitable for long-distance links with insufficient optical power margin, requiring high-sensitivity optical modules.

Technical Characteristics:

  • Passive component with extremely high reliability, introducing no single point of failure
  • Complete physical layer replication with zero packet loss, providing the highest acquisition accuracy
  • Does not depend on switch configuration and does not occupy business ports
  • Only applicable to fiber optic links; cannot be used with electrical ports

Applicable Scenarios:

  • Core fiber optic links and backbone links
  • 10-gigabit and above high-speed links
  • Scenarios requiring high acquisition accuracy
  • Third-party links where port mirroring cannot be configured

5.1.3 Flow Protocol Acquisition Principle

Flow protocol acquisition is based on the flow export function of network devices. Network devices perform statistics on passing traffic and generate flow records, sending them over the network to the traffic analysis device. The device only processes flow records without accessing raw packets.

Mainstream Flow Protocols:

  • NetFlow: Flow technology developed by Cisco Systems, with versions including V5, V7, and V9. V9 supports template-based extension and is the most widely used flow protocol.
  • sFlow: Sampling flow technology proposed by InMon Corporation, combining packet sampling with interface counter methods. Extremely low overhead, suitable for high-speed networks.
  • IPFIX: IETF-standardized IP Flow Information Export protocol, developed based on NetFlow V9, with excellent extensibility and interoperability.
  • NetStream: Flow technology from Huawei, similar in principle to NetFlow, compatible with mainstream versions.

Working Process:

1. Enable the flow export function on network devices such as routers and switches, configuring parameters including sampling ratio, active timeout, and inactive timeout.

2. Network devices classify and aggregate packets passing through, generating flow records based on five-tuple identifiers and calculating statistics for each flow including packet count, byte count, and start/end times.

3. Network devices encapsulate flow records into UDP packets and send them to the traffic analysis device at configured export intervals.

4. The traffic analysis device receives flow records, performs parsing, aggregation, statistical processing, and visual presentation.

Technical Characteristics:

  • Extremely low acquisition overhead with negligible impact on network device performance
  • Enables full-network broad coverage with a single analysis device capable of managing hundreds of network devices
  • Can only obtain flow statistical information; deep packet analysis is not possible
  • Data under sampling mode represents estimated values, not precise statistics

Applicable Scenarios:

  • WAN links and multi-branch links
  • Large-scale network macroscopic traffic monitoring
  • Bandwidth planning and traffic trend analysis

5.2 Deep Packet Inspection (DPI) Working Principle

Deep Packet Inspection (DPI) is the core technology used by network traffic analysis devices to identify application protocols and extract business information. Unlike traditional shallow inspection that only examines packet headers such as IP headers and TCP headers, DPI deeply parses the application-layer payload content of data packets to precisely identify the application and business type to which the traffic belongs.

5.2.1 DPI Technical Implementation Approaches

The LA-NTA device adopts a hybrid identification engine combining multiple DPI technologies, balancing identification accuracy and processing performance:

Port-based Identification

Preliminary classification based on IANA-assigned well-known port numbers — e.g., port 80 corresponds to HTTP, port 443 to HTTPS, and port 22 to SSH — serving as a rapid initial screening method. This method is fast but has low accuracy, as many applications use dynamic ports or port multiplexing and cannot be accurately identified by port alone.

Feature String-based Identification

Identifies protocols by matching specific feature strings in application-layer payloads. This is the most classic DPI implementation method. Examples include the “GET /” and “POST /” request lines of the HTTP protocol, the “220 ” response code of the FTP protocol, and proprietary protocol headers of specific applications. The device contains thousands of protocol feature rules, employing multi-pattern matching algorithms for high-speed matching.

Protocol Behavior-based Identification

For protocols without obvious feature strings, identification is performed by analyzing behavioral patterns during communication — for example, the request-response pattern of the DNS protocol, the multi-connection characteristics of P2P protocols, and the RTP stream characteristics of VoIP protocols. This method has certain identification capability for encrypted and unknown protocols.

Statistical Feature-based Identification

Uses machine learning algorithms to model statistical characteristics of traffic (packet length distribution, time intervals, upload/download ratios, connection frequency, etc.) to identify application categories of encrypted traffic and unknown protocols. This method does not require parsing packet contents, making it suitable for coarse-grained identification of encrypted traffic such as HTTPS.

Encrypted Handshake Information-based Identification

For TLS encrypted traffic, identifies accessed domains and service types by parsing clear-text fields in the Client Hello handshake, such as SNI (Server Name Indication) and certificate information, achieving application identification without decrypting traffic.

5.2.2 DPI Processing Flow

The complete DPI processing flow consists of the following steps:

1. Packet Reassembly: Reassembles IP fragmented packets and TCP out-of-order packets to reconstruct the complete application-layer data stream, ensuring feature matching accuracy.

2. Flow Table Matching: Searches the corresponding session flow table based on five-tuple identifiers. If the flow has already been identified, it is directly classified without redundant detection.

3. Feature Matching: For unidentified flows, applies multiple detection methods sequentially, including port matching, feature string matching, and behavior matching.

4. Protocol Decoding: After identifying the specific protocol, structurally decodes application-layer content according to protocol specifications, extracting key fields such as HTTP URL, Host, User-Agent, and DNS query domain names.

5. Result Output: Writes identification results and extracted fields into the session table for subsequent statistical analysis.

5.2.3 Protocol Identification Scope

The LA-NTA device supports identification of over 5,000 network protocols and applications, covering the following major categories:

  • Basic Network Protocols: IPv4/IPv6, TCP/UDP, ICMP, ARP, DNS, DHCP, NTP, SNMP, etc.
  • Web Application Protocols: HTTP/HTTPS, HTTP/2, WebSocket, FTP, TFTP, SMB, NFS, etc.
  • Email Protocols: SMTP, POP3, IMAP, Exchange, etc.
  • Database Protocols: MySQL, Oracle, SQL Server, PostgreSQL, Redis, MongoDB, etc.
  • Audio/Video Protocols: RTP/RTCP, RTSP, H.323, SIP, RTMP, HLS, WebRTC, etc.
  • Instant Messaging Applications: WeChat, QQ, DingTalk, WeCom, Feishu, Skype, etc.
  • Video Streaming Media: Tencent Video, iQIYI, Youku, Douyin, Kuaishou, Bilibili, etc.
  • Office and Cloud Applications: DingTalk, WeCom, Feishu, Office 365, Tencent Cloud, Alibaba Cloud, AWS, etc.
  • Industrial Control Protocols: Modbus, S7, DNP3, IEC 104, OPC UA, etc.
  • Encrypted and Tunneling Protocols: TLS/SSL, IPsec, GRE, VXLAN, NVGRE, WireGuard, etc.

5.3 Traffic Statistics and Performance Analysis Principles

5.3.1 Session Aggregation Principle

The traffic analysis device uses the five-tuple (source IP, destination IP, source port, destination port, transport layer protocol) as the unique identifier for sessions, aggregating all packets belonging to the same session for statistical processing, forming session records.

Session Lifecycle Management:

  • Session Creation: Creates a new session table entry upon receiving the first packet, initializing various statistical counters.
  • Session Update: Updates statistics including byte count, packet count, and latest packet timestamp each time a packet belonging to the session is received.
  • Session Aging: When a session has no new packets within the configured inactive timeout period, the session is determined to have ended. The session table entry is moved from the active table to the historical table and written to storage.
  • Active Timeout: For long-lived connections, forcibly exports an intermediate flow record at each configured active timeout interval, avoiding statistical deviation caused by long periods without output.
  • Seven-tuple Extension: Adds VLAN ID and MPLS labels to the five-tuple, applicable to multi-tenant and WAN scenarios for more granular session differentiation.

5.3.2 Key Performance Indicator Calculation Principles

Bandwidth Utilization

Bandwidth Utilization = Actual Data Transmitted / Link Theoretical Bandwidth × 100%

Calculates average bandwidth utilization within a statistical period (1 second, 1 minute, 5 minutes, etc.), while also recording peak bandwidth and the time of peak occurrence.

Round Trip Time (RTT)

Calculated through the TCP three-way handshake process: RTT = Time of receiving SYN+ACK − Time of sending SYN

The device measures the time difference during TCP connection establishment using precise packet timestamps to obtain the network round-trip latency of the connection.

Packet Loss Rate

Detects packet loss through TCP sequence number continuity: Calculates the ratio of sequence number discontinuities to the total packet count within a TCP session, distinguishing between uplink and downlink packet loss.

Packet Loss Rate = Number of Lost Packets / Total Packet Count × 100%

Retransmission Rate

Detects the quantity of TCP duplicate packets (packets with the same sequence number appearing again) and calculates the proportion of retransmitted packets to total packets.

Retransmission Rate = Number of Retransmitted Packets / Total Packet Count × 100%

Application Response Time

Application Response Time = Time of Server Receiving Request − Time of Client Sending Request

For request-response protocols such as HTTP and database protocols, measures the time difference between request packets and corresponding response packets to obtain application-layer response latency, distinguishing network latency from server processing latency.

Connection Success Rate

Connection Success Rate = Number of Successfully Established TCP Connections / Total TCP Connection Attempts × 100%

Calculates the connection establishment success rate by counting the number of SYN packets and corresponding SYN+ACK responses, reflecting network and service availability.

5.4 Anomaly Traffic Detection Principle

The LA-NTA device employs a three-tier detection architecture of baseline modeling + rule matching + intelligent algorithms to achieve precise identification of various abnormal traffic and security threats.

5.4.1 Baseline Modeling Detection

Baseline modeling is the foundation of behavioral anomaly detection. It establishes normal behavioral baselines across multiple dimensions by learning historical normal traffic data. Alerts are triggered when real-time traffic deviates from the baseline and reaches the configured threshold.

  • Baseline Dimensions: Includes total traffic baseline, per-IP traffic baseline, per-application traffic baseline, connection count baseline, new session rate baseline, and other multi-dimensional metrics.
  • Learning Period: Typically adopts a 7-day learning cycle, automatically distinguishing between workdays and holidays, and between working hours and non-working hours traffic patterns.
  • Dynamic Update: The baseline model continuously self-learns and updates to adapt to normal changes in network traffic, reducing false positives.
  • Deviation Determination: Uses standard deviation algorithm. When the real-time value exceeds the baseline ±N times the standard deviation range, it is determined as abnormal. The N value can be adjusted based on sensitivity requirements.

5.4.2 Rule Matching Detection

Performs pattern matching based on known attack signatures and security rules to detect known attack behaviors, achieving high detection accuracy and low false positive rates.

  • Attack Signature Library: Built-in thousands of attack detection rules, covering common attack types including DDoS attacks, port scanning, SQL injection, XSS attacks, webshell communication, trojans, and backdoors.
  • Signature Updates: Supports periodic online updates of the signature library to promptly cover new attack threats.
  • Custom Rules: Supports user-defined detection rules based on specific business characteristics to meet personalized security requirements.

5.4.3 Intelligent Algorithm Detection

Employs machine learning and artificial intelligence algorithms to detect unknown and covert attack behaviors, compensating for the lag in rule library updates.

  • Anomaly Detection Algorithm: Employs unsupervised learning algorithms such as Isolation Forest and cluster analysis to identify abnormal traffic deviating from normal patterns.
  • Threat Classification Algorithm: Uses deep learning models to classify abnormal traffic and determine threat types and risk levels.
  • Correlation Analysis: Performs correlation analysis on multiple isolated alert events to reconstruct the complete attack chain and enhance alert value.

5.5 Full Traffic Traceback Principle

Full traffic traceback is one of the core values of the traffic analysis device. Its essence is to completely preserve all original packets transmitted on the network, enabling the review of network communication content at any historical moment, similar to playing back a video recording, for fault diagnosis and security forensics.

5.5.1 Storage Architecture Principle

The LA-NTA device adopts a streaming direct-write storage architecture to ensure stable writes under high bandwidth:

  • Zero-Copy Write: Packets are written directly from the capture NIC to the storage medium without multiple memory copies, reducing CPU overhead and write latency.
  • Ring Buffer: A high-speed ring buffer is set up in memory to smooth the difference between burst traffic and storage write speed, preventing packet loss caused by instantaneous traffic spikes.
  • File Slicing Storage: Original packets are stored in slices based on fixed time intervals or file sizes. Each slice is an independent pcap format file, facilitating rapid location and retrieval.
  • Index Acceleration: Multi-dimensional indexes (5-tuple, time, protocol, etc.) are established for each storage slice. Retrieval first quickly locates the corresponding slice file through the index, then reads the file content, greatly improving traceback speed.

5.5.2 Data Retention Strategy

  • Circular Overwrite: When storage space reaches the configured threshold (e.g., 80%), the oldest historical data is automatically overwritten, always retaining the latest traffic data.
  • Tiered Storage: Hot data (last 7 days) is stored on high-speed SSD, warm data (7-30 days) is stored on high-capacity HDD, and cold data (over 30 days) can be archived to external storage.
  • Critical Data Locking: Traffic data from key event time periods can be locked to prevent circular overwriting, permanently retained as evidence.
  • On-Demand Export: Supports conditional filtering to export traffic data for specified time periods, specified IPs, and specified protocols as standard pcap files for offline analysis by third-party tools.

Chapter 6 Product Technical Specifications

6.1 Hardware Technical Specifications

The LA-NTA series includes multiple models covering the full range of requirements from entry-level to high-end flagship. The core hardware specifications of each model are shown in the table below.

Parameter LA-NTA-1000-D-T2 LA-NTA-10000-R-T8 LA-NTA-40000-R-T16 LA-NTA-100000-R-T32
Deployment Form Factor Desktop 2U Rack-mount 2U Rack-mount 4U Rack-mount
Maximum Processing Bandwidth 1Gbps 10Gbps 40Gbps 100Gbps
Maximum Concurrent Sessions 1 million 10 million 40 million 100 million
New Sessions Per Second 10,000 100,000 400,000 1,000,000
Capture Interface Configuration 4×GE Copper Ports 2×SFP Optical Ports, 8×SFP+ Optical Ports, 4×GE Copper Ports 4×QSFP+ Optical Ports, 8×SFP+ Optical Ports 8×QSFP28 Optical Ports, 16×SFP+ Optical Ports
Interface Rate 10/100/1000Mbps 10M/100M/1G/10G Auto-negotiation 1G/10G/40G Auto-negotiation 10G/25G/40G/100G Auto-negotiation
CPU Processor 8-core 2.0GHz 32-core 2.5GHz 48-core 2.7GHz 64-core 3.0GHz
System Memory 16GB DDR4 64GB DDR4 128GB DDR4 256GB DDR5
Storage Capacity 2TB SSD 8TB SSD + 2×4TB HDD 16TB SSD + 4×8TB HDD 32TB NVMe SSD + 12×16TB HDD
Storage Mode Circular Overwrite Circular Overwrite / Tiered Storage Circular Overwrite / Tiered Storage Circular Overwrite / Tiered Storage
Management Interfaces 1×GE Management Port, 1×Console Port 2×GE Management Ports, 1×Console Port, 2×USB3.0 2×GE Management Ports, 1×Console Port, 2×USB3.0, 1×IPMI Port 2×10GE Management Ports, 1×Console Port, 2×USB3.0, 1×IPMI Port
Power Supply Configuration Single Power Supply 60W 1+1 Redundant 500W 1+1 Redundant 800W 2+2 Redundant 2000W
Input Voltage AC 100-240V AC 100-240V AC 100-240V AC 100-240V
Power Consumption ≤50W ≤350W ≤600W ≤1500W
Operating Temperature 0°C~40°C 5°C~40°C 5°C~40°C 5°C~35°C
Storage Temperature -20°C~60°C -20°C~60°C -20°C~60°C -20°C~60°C
Operating Humidity 10%~90% Non-condensing 10%~90% Non-condensing 10%~90% Non-condensing 10%~90% Non-condensing
Dimensions (W×D×H) 280×220×45mm 440×500×88mm 440×550×88mm 440×680×176mm
Weight 2.5kg 15kg 20kg 45kg
Mounting Method Desktop Placement 19-inch Rack Mounting 19-inch Rack Mounting 19-inch Rack Mounting

6.2 Software Functional Specifications

6.2.1 Traffic Capture Specifications

  • Supported Capture Methods: Port mirroring capture, optical splitter capture, NetFlow V5/V9 capture, sFlow capture, IPFIX capture, NetStream capture
  • Supported Link Types: Ethernet copper ports, single-mode/multi-mode fiber, aggregated links, Trunk links
  • Supported Encapsulation Types: Ethernet II, 802.1Q VLAN, QinQ, MPLS, PPPoE, VXLAN, GRE, IPsec
  • Timestamp Precision: Nanosecond-level hardware timestamp, accuracy ±10ns
  • Packet Capture Rate: 99.999% at line rate, zero packet loss
  • Maximum Supported MTU: 9600 bytes (jumbo frame support)

6.2.2 Protocol Parsing Specifications

  • Supported Protocol Layers: Full protocol stack parsing from Layer 2 to Layer 7
  • Number of Supported Protocols: ≥5000 types, continuously updated
  • Application Identification Accuracy: ≥95% (mainstream applications)
  • Protocol Update Frequency: Monthly signature library updates, with emergency update support
  • Custom Protocol Support: Provides protocol signature customization interface
  • Encrypted Traffic Identification: Supports TLS handshake parsing, SNI identification, and encrypted traffic behavior analysis

6.2.3 Statistical Analysis Specifications

  • Statistics Dimensions: Time, source IP, destination IP, source port, destination port, protocol, application, VLAN, interface, zone, etc.
  • Statistics Metrics: Bandwidth, rate, packet count, byte count, connection count, new connection rate, RTT latency, packet loss rate, retransmission rate, response time, success rate, etc. — ≥100 metrics
  • Statistics Granularity: 1 second, 10 seconds, 1 minute, 5 minutes, 1 hour, 1 day, and other selectable granularities
  • Data Retention Period: Statistical data ≥12 months; raw packets retained based on storage capacity
  • Query Response Time: Single-condition query ≤3 seconds; multi-condition combined query ≤10 seconds

6.2.4 Security Detection Specifications

  • Detection Capabilities: DDoS attack detection, port scanning detection, brute-force attack detection, abnormal external connection detection, data exfiltration detection, vulnerability exploitation detection, webshell detection, cryptocurrency mining behavior detection, etc.
  • Attack Signature Rules: ≥5000 rules, regularly updated
  • Detection Accuracy: ≥90%
  • Alert Methods: Web popup, audible/visual alarm, email alert, SMS alert, Syslog reporting, SNMP Trap, API interface push
  • Alert Levels: Four-level classification — Critical, Major, Minor, Warning

6.2.5 System Management Specifications

  • Management Methods: Web GUI, CLI command line, SNMP V2/V3, RESTful API
  • User Management: Supports multi-user, role-based permission management, and separation of duties (three-power separation)
  • Log Audit: Complete operation log recording, supporting log query and export
  • System Upgrade: Supports online upgrade via Web interface and local file upgrade
  • Data Backup: Supports configuration backup, data backup, and one-click restore
  • Time Synchronization: Supports NTP and PTP time synchronization
  • Northbound Interfaces: RESTful API, Syslog, SNMP, Kafka, NetFlow forwarding

6.3 Reliability and Environmental Specifications

  • Mean Time Between Failures (MTBF): ≥100,000 hours
  • Power Redundancy: High-end models support 1+1/2+2 redundancy with hot-swap capability
  • Fan Redundancy: N+1 redundant fans with hot-swap support
  • Disk Redundancy: Supports RAID 1/5/6/10; no data loss on disk failure
  • Protection Rating: IP30 (rack-mount), IP40 (industrial embedded)
  • Immunity Capability: Complies with GB/T 17626 Electromagnetic Compatibility standard
  • Certifications: CCC certification, CE certification, RoHS certification, Classified Protection Compliance certification

6.4 Performance Benchmark Test Data (Reference)

The following are test data from third-party laboratory standard environment tests, provided for reference:

Test Item Result
10Gbps line-rate 64-byte small packet test Capture rate 100%, zero packet loss, CPU utilization ≤45%
10Gbps mixed packet test (average packet length 512 bytes) Protocol identification rate 98.7%, stable writing, zero packet loss
Concurrent session stress test 10 million concurrent sessions stable operation for 72 hours, no memory leak, no abnormal session aging
Query performance test (10TB historical data) Query by IP + time range, results returned in ≤8 seconds

Chapter 7 Product Functions and Features

7.1 Core Functions

7.1.1 Real-time Traffic Monitoring Function

Real-time traffic monitoring is the most basic and commonly used function of the device, providing operations personnel with real-time visual views of network-wide traffic to identify traffic anomalies at the earliest opportunity.

  • Network-wide Traffic Overview: Displays core indicators including total network ingress/egress bandwidth, total connection count, Top application share, alert overview, etc., presented in multiple formats such as dashboards, trend curves, and pie charts, with second-level data refresh.
  • Link-level Real-time Monitoring: Supports viewing real-time traffic trends by physical interface, logical link, VLAN, and other dimensions; displays current rate, peak rate, and bandwidth utilization; supports comparative display of multiple links.
  • Top Traffic Ranking: Real-time display of Top N source IPs, destination IPs, application protocols, ports, and sessions by traffic volume; supports sorting by byte count, packet count, connection count, and other metrics.
  • Traffic Distribution Analysis: Displays traffic distribution share by application, protocol, zone, department, and other dimensions, visually presenting traffic composition.
  • Real-time Alert Display: Real-time popup display of the latest alert events, color-coded by severity level, with click-to-navigate from alerts to the corresponding analysis page.

7.1.2 Multi-dimensional Traceback Analysis Function

Traceback analysis is a core tool for investigating historical faults and security incidents, supporting multi-dimensional combined condition retrieval to quickly locate target traffic.

  • Multi-dimensional Retrieval: Supports combined filtering by dozens of conditions including time range, source/destination IP, source/destination port, protocol type, application name, VLAN ID, packet size, TCP flags, etc., with both fuzzy and exact matching support.
  • Session List Display: Query results are presented as a session list, displaying key metrics for each session including start/end time, source/destination information, byte count, packet count, latency, packet loss, etc., with multi-column sorting support.
  • Session Detail Analysis: Clicking a single session allows viewing the detailed communication process, including packet sequencing, TCP sequence number changes, latency variations, and application-layer content summaries.
  • Raw Packet Decoding: Supports detailed protocol decoding of specified packets, displaying field details at each protocol layer, compatible with Wireshark display format, facilitating in-depth analysis by professionals.
  • Traffic Replay: Supports replaying historical traffic processes along a time axis, intuitively reproducing traffic changes before and after an event.
  • Data Export: Supports exporting query results as CSV format reports, and exporting raw packets as pcap format files for further analysis by third-party tools.

7.1.3 Network Performance Analysis Function

The network performance analysis function focuses on network transmission quality, quantitatively assessing network health and assisting in locating performance bottlenecks.

  • Link Quality Analysis: Calculates key performance indicators for each link including bandwidth utilization, average latency, packet loss rate, retransmission rate, etc.; generates quality scores and identifies degraded links.
  • TCP Performance Analysis: In-depth analysis of TCP connection performance, calculating metrics such as connection establishment latency, handshake success rate, retransmission count, zero window count, out-of-order count, etc., to locate TCP-level performance issues.
  • Latency Distribution Analysis: Displays the distribution ranges of RTT latency, calculates the proportion of connections within different latency ranges, and identifies high-latency sessions.
  • Business Quality Assessment: For specific business protocols such as HTTP, database, and email, calculates metrics including business response time, transaction success rate, error code distribution, etc., to quantitatively assess business service quality.
  • Performance Trend Analysis: Displays performance indicator trends by day, week, month, and year; analyzes performance degradation patterns to provide data support for network optimization.

7.1.4 Application Traffic Analysis Function

Application traffic analysis helps administrators understand the usage of various applications on the network, optimize bandwidth resource allocation, and control non-business traffic.

  • Application Traffic Ranking: Calculates traffic rankings for all identified applications, displaying traffic share and change trends.
  • Application Traffic Trend: Displays traffic change curves for specified applications within selected time periods, supporting multi-application comparison.
  • Application User Distribution: Identifies the Top user IPs using a specific application, locating high-volume traffic consumers.
  • Application Quality Analysis: For critical applications, analyzes quality indicators such as access latency, success rate, and stall rate.
  • Application Access Relationships: Visualizes application access topology, presenting client-server access relationships and traffic volumes.

7.1.5 Security Threat Detection Function

The security threat detection function identifies attack behaviors and security risks in the network based on traffic analysis, building a network-level security defense line.

  • DDoS Attack Detection: Detects various denial-of-service attacks including SYN Flood, UDP Flood, ICMP Flood, and DNS Query Flood; identifies attack sources and targets; calculates attack traffic volume.
  • Scanning Behavior Detection: Detects various scanning behaviors including port scanning, IP range scanning, and vulnerability scanning; identifies scanning sources and targets.
  • Brute-force Attack Detection: Detects brute-force attacks against SSH, RDP, FTP, database, and other services; calculates attempt counts and identifies attack sources.
  • Abnormal External Connection Detection: Detects abnormal external connection behaviors of internal hosts, including connections to overseas malicious IPs, dark web addresses, and C2 servers; leverages threat intelligence to improve accuracy.
  • Lateral Movement Detection: Detects abnormal access, port probing, and privilege propagation behaviors between internal hosts, identifying internal network penetration attacks.
  • Data Exfiltration Detection: Detects potential data exfiltration behaviors including large-volume outbound traffic, sensitive file transfers, and abnormal cloud drive uploads.
  • Cryptocurrency Mining Detection: Identifies mining trojan communication through mining pool communication signatures and traffic behavior patterns.
  • Web Attack Detection: Detects Web application layer attacks including SQL injection, XSS cross-site scripting, command injection, and webshell connections.

7.1.6 Reporting and Statistics Function

The reporting function transforms analysis results into standardized reports, meeting requirements for routine operations reporting, compliance auditing, and trend analysis.

  • Built-in Report Templates: Provides dozens of built-in templates including comprehensive traffic daily/weekly/monthly/annual reports, Top traffic reports, performance quality reports, security alert reports, and application analysis reports.
  • Custom Reports: Supports user-defined report content, statistics dimensions, display styles, and generation cycles to meet personalized reporting needs.
  • Automatic Generation and Push: Supports automatic report generation at configured intervals, delivered to designated recipients via email.
  • Multi-format Export: Supports export in PDF, Word, Excel, HTML, and other formats to meet different application requirements.
  • Report Template Management: Supports saving, modifying, deleting, importing, and exporting report templates.

7.1.7 System Management Function

  • Device Configuration Management: Provides full-parameter configuration including interface configuration, routing configuration, time configuration, storage configuration, and capture policy configuration.
  • User Permission Management: Supports multi-user account management with role-based access control (RBAC); supports assignment of different functional and data permissions; supports separation of duties among administrator, operator, and auditor roles.
  • System Status Monitoring: Real-time monitoring of hardware operating status including CPU, memory, disk, interface, power supply, and fans; automatic alerting on anomalies.
  • Upgrade Management: Supports online and local upgrades of system firmware, protocol signature library, and attack rule library; upgrade process does not affect business capture.
  • Data Backup and Restore: Supports system configuration backup and user data backup, with one-click restore to backup state.
  • Log Audit: Complete recording of all user operation logs, system operation logs, and security alert logs; supports query, filtering, and export to meet audit requirements.
  • Northbound Interface Management: Provides standardized API interface documentation, supports third-party system integration configuration, and configures data push parameters.

7.2 Product Features

7.2.1 High-performance Hardware Architecture, Line-rate Processing with Zero Packet Loss

  • Employs FPGA + multi-core CPU heterogeneous acceleration architecture. FPGA handles high-speed packet capture and preprocessing, while the CPU handles deep parsing and business analysis — each performing its designated function, ensuring 100% line-rate processing capability.
  • Equipped with DPDK (Data Plane Development Kit) for kernel bypass and zero-copy technology, multiplying packet processing performance with lower CPU utilization.
  • Utilizes high-speed memory and NVMe storage architecture to eliminate I/O bottlenecks, ensuring stable writes without packet loss under high traffic impact.
  • Nanosecond-level hardware timestamping provides precise latency and performance measurement, forming the data foundation for refined analysis.

7.2.2 Full-Protocol Deep Parsing, Precise Identification with Wide Coverage

  • Supports identification of over 5,000 network protocols and applications, covering protocols across traditional internet, industrial control, cloud computing, Internet of Things, and all other domains.
  • Employs a hybrid DPI identification engine combining signature matching, behavioral analysis, statistical modeling, encrypted handshake parsing, and other techniques, achieving industry-leading identification accuracy.
  • Continuously updates the protocol signature library, keeping pace with application updates and iterations, promptly covering new applications and protocols.
  • Supports user-defined protocol signatures to meet private protocol identification requirements in special industries.

7.2.3 Full Traffic Traceback Storage, Event Traceability with Evidence

  • Complete retention of all raw packets, supporting traffic traceback at any historical moment and packet-level deep analysis.
  • Intelligent tiered storage architecture balancing performance and capacity, maximizing storage retention period.
  • Multi-dimensional index acceleration provides second-level response on billion-scale data, greatly improving investigation efficiency.
  • Standard pcap format storage, compatible with mainstream analysis tools such as Wireshark, ensuring strong data interoperability.
  • Critical data lock protection prevents key evidence from circular overwriting, meeting compliance and audit requirements.

7.2.4 Intelligent Security Detection, Proactive Threat Defense

  • Three-tier detection engine architecture combining baseline modeling + rule matching + intelligent algorithms, covering both known and unknown threat detection.
  • Continuously updated threat signature library providing timely response to new attack methods.
  • Intelligent baseline self-learning automatically adapts to network changes, reducing false positive rates.
  • Multi-event correlation analysis reconstructs complete attack chains, enhancing alert value and reducing invalid alerts.
  • Rich alert linkage methods supporting coordinated response with firewalls, EDR, and other security devices.

7.2.5 User-friendly Visualization, Efficient Operations and Maintenance

  • B/S architecture Web management interface requiring no client installation, accessible anytime, anywhere.
  • Rich visualization charts — dashboards, trend charts, pie charts, bar charts, heat maps, and topology diagrams — presenting data intuitively and clearly.
  • User-friendly interaction design with convenient drill-down analysis, one-click navigation from macro overview to micro packet level.
  • Supports large-screen display mode, suitable for command centers and monitoring centers.
  • Supports multi-tenancy and distributed permission management, meeting multi-level O&M needs of large organizations.

7.2.6 High-reliability Design, Guaranteed Stable Operation

  • Industrial-grade hardware selection — all key components adopt industrial and enterprise-grade specifications to ensure long-term stable operation.
  • Redundant architecture design — power supplies, fans, and storage all support redundant configurations; single point of failure does not affect business.
  • Intelligent thermal control cooling system dynamically adjusts based on load, saving energy and reducing noise while extending hardware lifespan.
  • Comprehensive hardware monitoring and protection mechanisms with automatic over-voltage, over-current, and over-temperature protection.
  • MTBF exceeding 100,000 hours, meeting 7×24-hour continuous operation requirements.

7.2.7 Flexible Deployment and Scalability, Adapting to Diverse Scenarios

  • Multiple deployment form factors — desktop, rack-mount, blade, and embedded — adapting to different environments.
  • Multiple capture methods — mirroring, optical splitting, and flow protocols — flexibly selectable, compatible with various network environments.
  • Modular software and hardware design — interfaces, storage, and functional modules can be expanded on demand, protecting user investment.
  • Rich northbound interfaces, easily integrated with existing O&M systems and security platforms.
  • Supports distributed deployment with centralized management, adapting to large-scale cross-regional networks.

Chapter 8 Product Application Scenarios

8.1 Enterprise Data Center Scenario

8.1.1 Scenario Overview

The enterprise data center hosts the company’s core business systems and is the heart of the enterprise IT architecture. The stability and performance of the data center network directly affect normal business operations. Data center networks are characterized by high traffic volumes, multiple business systems, complex access relationships, and wide-ranging fault impact, demanding extremely high depth and precision in traffic analysis.

8.1.2 Deployment Solution

At the critical links between core switches and aggregation switches in the data center, deploy LA-NTA full traffic analysis devices using port mirroring or optical splitters to perform full capture and analysis of core link traffic. For ultra-large data centers, a distributed probe + central analysis platform architecture can be adopted, deploying probes beside each cabinet or each aggregation switch, with local capture and preprocessing before reporting to the central platform for unified analysis.

8.1.3 Core Value

  • Core Business Assurance: Real-time monitoring of traffic and performance indicators of core business systems; timely detection of slow business access, transaction failures, and other issues; rapid determination of whether problems are network-related or server-related, shortening fault investigation time.
  • Network Fault Investigation: When network interruptions, packet loss, high latency, or other faults occur, quickly locate the fault point and cause through traffic traceback, reducing business interruption duration.
  • Capacity Planning Basis: Statistical analysis of traffic growth trends for each data center link and business, providing precise data support for bandwidth expansion and equipment upgrades, avoiding blind investment.
  • East-West Traffic Monitoring: Monitoring horizontal access traffic between servers within the data center to detect abnormal lateral movement and internal network attacks, compensating for the limitations of traditional perimeter security devices.
  • Change Verification: After network configuration changes or business system launches, verifying change effectiveness through traffic data to confirm normal business operation.

8.2 Internet Egress Scenario

8.2.1 Scenario Overview

The internet egress is the connection boundary between the enterprise internal network and the external internet — the area with the highest bandwidth consumption and security risk. Egress bandwidth is typically the bottleneck resource of the enterprise network and also the primary channel for external attacks to enter.

8.2.2 Deployment Solution

At the inner side of the enterprise internet egress router or firewall, deploy traffic analysis devices using optical splitters or port mirroring to capture and analyze the full traffic entering and exiting the internet. For multi-egress scenarios, all egress traffic can be aggregated for unified analysis.

8.2.3 Core Value

  • Bandwidth Resource Management: Precisely calculates internet egress bandwidth utilization; identifies Top traffic applications and Top traffic users; analyzes bandwidth consumption composition to provide a basis for bandwidth expansion and optimization.
  • Non-business Traffic Control: Identifies video, gaming, P2P downloading, and other non-work traffic; assesses their bandwidth consumption; assists in formulating internet behavior management policies to guarantee business bandwidth.
  • Egress Security Protection: Detects various attack behaviors from the internet, such as DDoS attacks, vulnerability scanning, and intrusion attempts; timely detection and early warning of security threats.
  • Internet Behavior Audit: Records internet access behaviors of internal users to meet compliance audit requirements and trace violations of internet usage policies.
  • Link Quality Monitoring: Monitors quality indicators such as latency and packet loss on the internet egress; evaluates carrier link quality; provides data for carrier SLA assessments.

8.3 WAN and Multi-branch Scenario

8.3.1 Scenario Overview

Large enterprises, chain organizations, and government agencies typically have multiple branch offices interconnected through WAN (MPLS VPN, SD-WAN, internet VPN, etc.) between headquarters and branches. WAN links are typically characterized by low bandwidth, high cost, wide distribution, and difficult management, with numerous branch nodes and weak O&M capabilities.

8.3.2 Deployment Solution

Employ a hybrid deployment approach of flow collection + distributed probes: the headquarters core deploys a high-end traffic analysis platform, while routers at each branch enable NetFlow/sFlow flow export and report to the headquarters platform. For important branches or branches with high bandwidth, deploy small probe devices to achieve deep analysis.

8.3.3 Core Value

  • WAN Bandwidth Optimization: Calculates bandwidth utilization and traffic composition of each WAN link; identifies high-consumption applications; optimizes QoS policies to guarantee WAN access quality for critical businesses.
  • Branch Traffic Visualization: Achieves unified visual management of all branch traffic, solving the branch network black-box problem; headquarters O&M personnel can remotely view branch network conditions.
  • Remote Fault Investigation: When network problems occur at branches, headquarters can remotely analyze and investigate through traffic data without dispatching engineers on-site, significantly reducing O&M costs.
  • SD-WAN Effectiveness Evaluation: Evaluates the actual effectiveness of SD-WAN intelligent path selection and application optimization, quantifying optimization benefits.
  • Branch Security Monitoring: Unified detection of security threats across all branches, raising the overall security protection level.

8.4 Carrier Network Scenario

8.4.1 Scenario Overview

Carrier networks carry internet access services for massive numbers of users, characterized by large network scale, high link bandwidth, and large user populations. Fine-grained monitoring and management of network-wide traffic is required to ensure network service quality while providing data support for value-added services.

8.4.2 Deployment Solution

Deploy high-performance, high-bandwidth traffic analysis devices at key nodes such as carrier backbone networks, metro network cores, and IDC egresses, using optical splitters for link traffic capture. Simultaneously, enable NetFlow/IPFIX flow export on network-wide routers to combine network-wide macro monitoring with deep analysis at key nodes.

8.4.3 Core Value

  • Network Operation Situational Awareness: Real-time understanding of network-wide traffic distribution and operational status; timely detection of network congestion, abnormal traffic, and equipment faults; ensuring stable network operation.
  • Network Planning and Optimization: Analyzing traffic flow directions and growth trends based on traffic data, providing scientific basis for network expansion, routing optimization, and link scheduling.
  • User Behavior Analysis: Analyzing user internet behavior characteristics and application preferences, providing data support for precision marketing and value-added service promotion.
  • Abnormal Traffic Scrubbing: Detecting DDoS and other large-scale traffic attacks; coordinating with traffic scrubbing systems for mitigation; protecting network and customer business security.
  • Interconnection Settlement: Precisely calculating inter-network interconnection traffic, providing accurate data basis for network settlement.

8.5 Education Campus Network Scenario

8.5.1 Scenario Overview

University campus networks are characterized by large user populations, rich application variety, obvious traffic peaks, and difficult network management. Campus networks also face multiple requirements including compliance management, bandwidth assurance, and network security.

8.5.2 Deployment Solution

Deploy traffic analysis devices at key nodes including the campus network egress, core links, teaching areas, and dormitory areas to achieve unified monitoring and analysis of network-wide traffic.

8.5.3 Core Value

  • Egress Bandwidth Management: Analyzes campus network egress traffic composition; identifies high-traffic applications such as video, gaming, and downloading; formulates reasonable bandwidth management policies to guarantee teaching and research bandwidth.
  • Network Fault Investigation: Quickly locates network faults within the campus network, such as broadcast storms, loops, and virus attacks, improving O&M efficiency.
  • Internet Behavior Management: Standardizes campus internet usage behavior; identifies non-compliant network applications; traces access to inappropriate information; meeting campus network security management requirements.
  • Research Network Assurance: Provides dedicated bandwidth quality monitoring for key laboratories and research projects, ensuring stable transmission of research data.
  • Classified Protection Compliance: Retains network access logs and traffic data, meeting compliance requirements of classified protection and education industry regulations.

8.6 Healthcare Industry Scenario

8.6.1 Scenario Overview

Hospital information systems directly affect patient safety and medical service quality. Core business systems such as HIS, EMR, and PACS demand extremely high network reliability and performance. Additionally, medical data involves patient privacy, with strict data security and compliance requirements.

8.6.2 Deployment Solution

Deploy traffic analysis devices at critical links including the hospital core switch, data center egress, internet egress, and medical insurance dedicated line to comprehensively monitor business and external connection traffic.

8.6.3 Core Value

  • Core Business Assurance: Real-time monitoring of network performance for core medical systems such as HIS and PACS; timely detection of slow access, stalling, and other issues; ensuring normal diagnosis and treatment operations.
  • Medical Data Security: Monitors abnormal access and outbound transmission of patient privacy data; prevents data leakage; complies with the Data Security Law and the Personal Information Protection Law.
  • Rapid Network Fault Location: During outpatient peak hours, quickly identifies the cause of network faults, shortening business interruption time and avoiding impact on patient visits.
  • Medical Insurance Dedicated Line Monitoring: Monitors the connectivity and quality of the medical insurance dedicated line, ensuring normal operation of medical insurance settlement services.
  • Classified Protection Compliance: Meets classified protection requirements for the healthcare industry, providing complete network auditing and traceability capabilities.

8.7 Government Agency Scenario

8.7.1 Scenario Overview

Government agency e-government networks carry important functions including government office operations, public services, and urban management. Network security and compliance requirements are extremely high, requiring compliance with Classified Protection Level 3 and above while ensuring stable and efficient operation of government services.

8.7.2 Deployment Solution

Deploy traffic analysis devices at the e-government external network egress, e-government internal network core, and boundaries of each business zone. Monitoring is performed by security domain division, achieving full-domain traffic visibility and control.

8.7.3 Core Value

  • Classified Protection Compliance Support: Full traffic retention and behavior auditing meet the network auditing and intrusion prevention requirements of classified protection, providing complete traceability and forensics capabilities.
  • Government Service Assurance: Ensures stable operation of core government systems including e-government services, government service platforms, and video conferencing, improving government service quality.
  • Security Threat Monitoring: Detects various attack behaviors targeting government networks; identifies advanced persistent threats (APTs); enhancing government network security protection capabilities.
  • Cross-department Data Exchange Monitoring: Monitors cross-department and cross-region data exchange traffic, ensuring the compliance and security of data transmission.
  • O&M Efficiency Improvement: Improves the efficiency of government network O&M management; quickly locates and resolves network issues; ensuring 7×24-hour availability of government systems.

8.8 Industrial Control Network Scenario

8.8.1 Scenario Overview

Industrial control networks are the core nervous system of critical infrastructure in electric power, petroleum, chemical, rail transit, and manufacturing industries. A fault or attack on an industrial network can lead to production stoppage or even safety accidents. Industrial network protocols are specialized with high real-time requirements and limited device computing power, making traditional IT traffic analysis devices unsuitable.

8.8.2 Deployment Solution

Deploy industrial-grade embedded traffic analysis devices in bypass mode at industrial core switches and ICS system boundaries, supporting deep parsing of industrial protocols without affecting the real-time performance of control systems.

8.8.3 Core Value

  • Industrial Protocol Parsing: Supports deep parsing of dozens of industrial control protocols including Modbus, S7, IEC104, and OPC UA, achieving visualization of industrial control networks.
  • Production Business Assurance: Monitors communication status of control systems; timely detection of communication interruptions, timeouts, and bit errors; ensuring stable production operation.
  • Industrial Control Security Protection: Detects attack behaviors, abnormal operations, and unauthorized device access targeting control systems; prevents ransomware and trojans from invading industrial control networks.
  • Operation Behavior Audit: Records all operation commands and communication processes of control systems, meeting industrial control system security audit requirements.
  • Fault Traceability Analysis: After a production accident, reconstructs the network communication process at the time of the accident through traffic traceback to identify the root cause.

Chapter 9 Product Installation

9.1 Pre-installation Preparation

9.1.1 Environmental Inspection

Before equipment installation, the installation environment must be inspected to ensure it meets equipment operating requirements:

  • Computer Room Environment Inspection
  • Verify the computer room temperature is within 5°C~40°C, avoiding direct sunlight on the equipment.
  • Verify the computer room relative humidity is between 10%~90%, with no condensation.
  • Verify the computer room is clean, free of excessive dust, corrosive gases, and strong electromagnetic interference.
  • Verify the equipment installation location is away from heat sources, water sources, and strong vibration sources.
  • Cabinet and Space Inspection
  • Verify the installation cabinet is a standard 19-inch cabinet with load-bearing capacity meeting the equipment weight requirements.
  • Verify sufficient installation space is reserved in the cabinet; rack-mount equipment requires at least 1U of clearance above and below for heat dissipation.
  • Verify adequate ventilation and operating space in front of and behind the cabinet — at least 60cm operating space in front and at least 40cm cabling space in the rear.
  • Verify the cabinet is properly grounded with grounding resistance ≤4Ω.
  • Power Environment Inspection
  • Verify the computer room provides compliant AC power with voltage range AC 100V~240V, frequency 50/60Hz.
  • Verify sufficient power outlets are available; redundant power supply models require two independent power feeds.
  • UPS uninterruptible power supply is recommended to ensure normal operation and data security during power failures.
  • Verify proper power grounding with neutral-to-ground voltage ≤1V.
  • Network Environment Inspection
  • Verify the interface type, rate, fiber type, and other parameters of the links to be monitored match the device interface specifications.
  • Verify the mirror port or optical splitter is ready and can output mirrored traffic normally.
  • Verify the management network is deployed and the device management port can connect to the management network.
  • Verify IP address planning and allocate management IP address, gateway, DNS, and other parameters for the device in advance.

9.1.2 Tools and Materials Preparation

The following tools and materials must be prepared before installation:

  • Phillips screwdriver (PH2)
  • Flat-head screwdriver
  • Anti-static wrist strap
  • Multimeter
  • Cable ties and cable clips
  • Label paper and marking pen
  • Cable tester and optical power meter (for optical port scenarios)
  • Laptop computer (for initial configuration)

9.1.3 Unpacking and Inspection

Perform unpacking and inspection according to the product checklist in Chapter 4. Check that the equipment appearance is intact, accessories are complete, model numbers are correct, and record the device serial number. Installation may proceed only after confirmation. When handling the equipment, handle with care to avoid impacts, wear an anti-static wrist strap when touching the equipment to prevent static damage to components.

9.2 Rack-mount Equipment Installation Steps

Rack-mount equipment uses standard 19-inch cabinet installation. The specific installation steps are as follows:

Step 1: Install L-shaped Mounting Brackets

  • Align the L-shaped mounting brackets on both sides of the device with the mounting holes on the device sides.
  • Use the supplied screws to secure the brackets to both sides of the device, tightening the screws to ensure they are firmly attached.
  • Install the left and right brackets symmetrically, confirming the front of the brackets is flush with the device front panel.

Step 2: Determine Installation Position

  • Select the equipment installation position on the cabinet pillars; it is recommended to install in the middle-lower section of the cabinet for better center of gravity stability.
  • Install 4 floating nuts on the cabinet square-hole rails at the corresponding height, 2 on each side, maintaining consistent spacing.
  • Ensure the floating nuts are firmly installed and can support the equipment weight.

Step 3: Mount the Equipment

  • With two people working together, lift the equipment and place it smoothly into the predetermined cabinet position.
  • Align the mounting holes of the equipment brackets with the floating nuts on the cabinet square-hole rails.
  • First insert two diagonal screws for initial fixation, then adjust the equipment to level.
  • Insert all four mounting screws, tightening diagonally in sequence, ensuring the equipment is firmly installed and level.

Step 4: Install Grounding

  • Locate the grounding terminal on the device rear panel.
  • Use the supplied grounding cable to connect the device grounding terminal to the cabinet grounding busbar.
  • Tighten the grounding screw to ensure reliable grounding.

Step 5: Installation Inspection

  • Check that the equipment is firmly installed with no looseness or tilting.
  • Check that the front and rear clearance meets ventilation requirements.
  • Confirm no debris around the equipment is blocking the ventilation openings.

9.3 Desktop Equipment Installation Steps

Desktop equipment installation is relatively simple, follow these steps:

  • Choose a flat, stable surface for placing the equipment, avoid edge positions to prevent falling
  • Securely attach the anti-slip rubber pads on the bottom of the equipment
  • Place the equipment steadily on the table, ensure sufficient heat dissipation space around the equipment, reserve at least 10cm of space on the left, right, and rear sides
  • Do not stack any items on top of the equipment to avoid blocking ventilation holes
  • Connect the ground wire to ensure reliable equipment grounding

9.4 Embedded Equipment Installation Steps

Industrial embedded equipment typically adopts DIN rail mounting or wall-mount installation:

DIN Rail Mounting

1. Pull open the rail mounting clips on the back of the equipment

2. Align the mounting clips with the DIN rail, first engage the upper edge

3. Press the lower part of the equipment inward, a “click” sound indicates the clips are locked

4. Slide the equipment left or right to adjust the position, confirm the installation is secure

Wall-Mount Installation

1. Use the wall-mount installation template to mark the mounting hole positions on the wall

2. Drive expansion screws into the marked positions

3. Align the equipment onto the screws and hang it in place, tighten the fixing nuts

4. Shake the equipment to confirm it is securely installed without loosening

9.5 Installation Safety Precautions

  • Personal Safety: At least two people must cooperate when mounting equipment on a rack to prevent equipment from falling and causing injury; pay attention to cabinet edges and corners during installation to avoid collisions
  • Electrostatic Protection: Anti-static wrist straps must be worn when touching equipment hardware to prevent static electricity from damaging circuit boards and chips
  • Power Safety: Ensure the power supply is disconnected before wiring the equipment; hot-plugging internal components is prohibited; power on only after power wiring is completed
  • Load-Bearing Safety: Ensure the cabinet load-bearing capacity meets the equipment weight requirements to avoid cabinet deformation or tipping
  • Heat Dissipation Safety: Strictly prohibit blocking the equipment ventilation holes; sufficient heat dissipation space must be reserved around the equipment to avoid overheating damage
  • Cleanliness Safety: Clean up installation debris promptly after installation, avoid screws, cable ties, and other debris falling into the equipment interior

10.1 Pre-Wiring Preparation

  • Confirm all cable specifications meet requirements; network cables, fiber optic cables, and power cables must be free of damage and kinks
  • Prepare label paper to identify each cable for subsequent maintenance
  • Confirm the equipment power switch is in the OFF position
  • Wear an anti-static wrist strap for electrostatic protection

10.2 Service Collection Interface Wiring

The service collection interface is used to connect network traffic requiring analysis. Based on the link type, it is divided into two wiring methods: electrical port wiring and optical port wiring.

10.2.1 Electrical Port Collection Wiring

Applicable to Gigabit and below Ethernet electrical port links, collected using port mirroring method:

Cable Selection: Use Cat5e or Cat6 standard network cables, distance not exceeding 100 meters; shielded network cables are recommended

Wiring Steps:

1. Insert one end of the network cable into the mirror destination port of the switch

2. Insert the other end of the network cable into the collection electrical port of the traffic analysis equipment

3. Observe the equipment interface indicator light: steady green indicates normal physical connection; orange blinking indicates data transmission

Precautions:

  • The collection port is a unidirectional receive interface and does not send data. Do not connect the collection port to the normal service network to avoid affecting services
  • Ensure the switch mirror port configuration is correct, and the mirror direction matches the traffic direction
  • Network cable termination must comply with the T568B standard, correct wire sequence to avoid crosstalk

10.2.2 Optical Port Collection Wiring

Applicable to fiber optic links, can use optical splitter collection or switch optical port mirror collection:

Optical Module Installation:

1. Remove the optical module, pinch both sides of the module, align it with the optical port slot of the equipment, and insert smoothly

2. A “click” sound indicates the optical module is fully seated; gently pull to confirm it will not come loose

3. Keep the optical module gold fingers clean, avoid touching with hands to prevent contamination

Optical Splitter Method Wiring (Recommended):

1. Disconnect the original service fiber optic link

2. Connect the transmitting-end fiber to the INPUT port of the optical splitter

3. Connect the OUTPUT main path port of the optical splitter to the original receiving-end equipment to restore the service link

4. Connect the TAP branch output port of the optical splitter to the optical port of the traffic analysis equipment

5. Use an optical power meter to measure the branch optical power, ensuring it is within the optical module receiving sensitivity range

Mirror Port Method Wiring:

1. Insert one end of the fiber jumper into the mirror destination optical port of the switch

2. Insert the other end into the optical port of the traffic analysis equipment

3. Confirm the optical modules at both ends match in specifications — rate, wavelength, and transmission distance must be consistent

Precautions:

  • Protect the fiber end faces during insertion and removal, avoid dust contamination and impact damage
  • The fiber bending radius shall not be less than 30mm, avoid excessive bending that causes excessive optical power loss
  • Single-mode and multi-mode fibers must not be mixed; corresponding optical modules must match
  • Before connecting the optical splitter, evaluate the link optical power margin to avoid service interruption caused by excessively low main path optical power

10.3 Management Interface Wiring

The management interface is used for equipment configuration management and data access, and must be connected to the management network.

Console Port Wiring

1. Use the included Console configuration cable; connect the RJ45 end to the equipment Console port

2. Connect the DB9 or USB end to the serial port/USB port of the configuration computer

3. Used for initial equipment configuration and emergency fault management

Management Network Port Wiring

1. Use a standard network cable to connect the device ETH management port to the management switch

2. The configuration computer must also be connected to the same management network, ensuring network connectivity

3. The management port is physically isolated from the service collection port to ensure management security

Precautions:

  • It is recommended to physically isolate the management network from the service network for enhanced security
  • The management port IP must be planned in advance to avoid conflicts with other devices on the network

10.4 Power Wiring

Single Power Supply Model:

1. Insert one end of the power cable into the equipment power interface and tighten the fixing clip

2. Insert the other end into the equipment room power outlet, confirming good contact

Redundant Power Supply Model:

1. Connect two power cables to the two power module interfaces of the equipment respectively

2. It is recommended to connect the two power cables to two different power supply circuits for power redundancy

3. Ensure both power circuits are supplying power normally; the equipment can still operate normally when one circuit is disconnected

Power Inspection:

1. After wiring, check that the power cable connections are secure without looseness

2. Confirm the power supply voltage is within the allowable range of the equipment

3. Confirm the power switch is in the OFF position; power on only after all wiring is completed

10.5 Alarm and Expansion Interface Wiring

Dry Contact Alarm Wiring:

  • The equipment provides a relay dry contact alarm output interface supporting normally open/normally closed modes
  • Use a two-core signal cable to connect to the alarm input port of the environment monitoring system
  • Enables centralized alarming for events such as equipment power failure, faults, and storage full

USB Expansion Wiring:

  • Can connect external USB drives and portable hard drives for data export and system upgrade
  • Can connect an external 4G module for remote management

Precautions:

  • Pay attention to the positive and negative polarity of alarm wiring to avoid reversed connections
  • External devices must comply with the equipment interface specifications to avoid damaging the equipment interface

10.6 Cable Arrangement and Labeling

After all wiring is completed, cable arrangement and labeling must be performed for subsequent maintenance management:

  • Classify and bundle various types of cables; separate power cables from signal cables to avoid interference
  • Use cable ties to secure cables to the cabinet cable management bars, keeping them neat and tidy
  • Affix labels at both ends of each cable, marking the cable purpose, connection positions at both ends, and numbering information
  • Fiber jumpers must use dedicated cable managers to avoid excessive bending
  • Reserve appropriate cable slack for equipment maintenance and relocation

10.7 Wiring Inspection and Verification

After all wiring is completed, perform inspection and verification according to the following steps:

  • Visually inspect that all interface wiring is correct, without wrong connections or missing connections
  • Check that all cable connections are secure without risk of loosening or falling off
  • Check the power wiring is correct without short circuit risk
  • Verify labels are accurate and clear
  • Confirm no debris around the equipment and ventilation is unobstructed
  • After preparation, the equipment can proceed to the power-on commissioning phase

11.1 First Power-On of Equipment

11.1.1 Final Pre-Power-On Inspection

  • Confirm all wiring is correct and error-free
  • Confirm the equipment power switch is in the OFF position
  • Confirm the equipment room power supply is normal and voltage is stable
  • Confirm the equipment ventilation openings are unobstructed

11.1.2 Power-On Operating Steps

1. Turn on the cabinet power outlet switch to supply power to the equipment

2. Press the power switch button on the equipment front panel; the power indicator lights up

3. Observe the equipment front panel indicator states:

  • Power LED: steady green indicates normal power supply
  • Running LED: green blinking indicates the system is starting and running normally
  • Alarm LED: steady red or blinking red indicates an abnormal alarm
  • Interface LED: steady green indicates normal link connection, blinking indicates data transmission

4. Wait for the system to start; rack-mount equipment takes approximately 3-5 minutes, desktop equipment approximately 2-3 minutes

5. When the running LED shows regular blinking, the system startup is complete

11.1.3 Power-On Status Inspection

  • Observe the equipment for abnormal noise, odor, or smoke; if present, immediately power off and inspect
  • Check whether fans are running normally without abnormal noise
  • Check whether the interface indicator states match expectations
  • Record the equipment startup time and initial status

11.2 Initial Configuration (Console Method)

For first-time use, the equipment requires basic configuration through the Console port to set management IP and other parameters.

11.2.1 Establishing Console Connection

1. Connect the Console cable between the equipment Console port and the configuration computer

2. Open terminal emulation software on the computer such as HyperTerminal, SecureCRT, or PuTTY

3. Configure serial port parameters:

  • Baud rate: 9600
  • Data bits: 8
  • Stop bits: 1
  • Parity: None
  • Flow control: None

4. Connect to the serial port and press Enter to enter the device command-line interface

11.2.2 System Login

1. After the system startup completes, the login prompt is displayed

2. Enter the default administrator account: admin

3. Enter the default password: admin123456

4. After the first successful login, the system forces a default password change; follow the prompts to set a new administrator password. The password must meet complexity requirements (at least 8 characters, including uppercase and lowercase letters, numbers, and special characters)

11.2.3 Configuring Management IP Address

# Enter system view
system-view

# Enter management interface view
interface eth0

# Configure IP address and mask
ip address 192.168.1.100 255.255.255.0

# Enable the interface
no shutdown

# Return to system view
exit

# Configure default gateway
ip route 0.0.0.0 0.0.0.0 192.168.1.1

# Configure DNS servers
dns server 114.114.114.114
dns server 8.8.8.8

# Save configuration
write memory

After configuration, use the show ip interface eth0 command to view the interface configuration and confirm the IP address is set correctly.

11.2.4 Configuring System Time

# Configure system time
clock set 14:30:00 2026-07-17

# Configure timezone
clock timezone Asia/Shanghai +8

# Configure NTP time synchronization (recommended)
ntp server cn.pool.ntp.org
ntp enable

Accurate system time is the foundation of traffic analysis and log auditing; time accuracy must be ensured.

11.3 Web Management Interface Login and Basic Configuration

After completing the management IP configuration, more intuitive configuration management can be performed through the Web interface.

11.3.1 Web Interface Login

1. Connect the configuration computer to the management network and set the computer IP to the same subnet as the device management IP

2. Open a standard browser such as Chrome or Firefox, and enter the device management IP address in the address bar, e.g., https://192.168.1.100

3. A security prompt appears; select continue to access (the device uses a self-signed certificate by default)

4. Enter the login page, input the administrator account and the changed password, and click Login

5. On first login, an initialization wizard appears; follow the wizard to complete basic configuration step by step

11.3.2 System Basic Configuration

Device Information Configuration

1. Navigate to [System Management] – [Device Information]

2. Set the device name, device location, contact person, contact phone number, and other information for asset management

3. Click Save

Network Configuration Confirmation

1. Navigate to [System Management] – [Network Configuration]

2. Confirm the management port IP, subnet mask, gateway, and DNS configurations are correct

3. Configure static routes, hostnames, and other parameters as needed

Time Configuration Confirmation

1. Navigate to [System Management] – [Time Configuration]

2. Confirm the timezone setting is correct and the system time is accurate

3. Confirm the NTP server configuration is normal and the time synchronization status is normal

User Permission Configuration

1. Navigate to [System Management] – [User Management]

2. Create user accounts with different roles based on operation and maintenance requirements, and assign appropriate permissions

3. It is recommended to disable or modify the default account to enhance security

11.4 Traffic Collection Configuration

11.4.1 Mirror Collection Interface Configuration

1. Navigate to [Collection Configuration] – [Physical Interface Configuration]

2. Locate the interface connected to mirrored traffic and click Edit

3. Set interface mode to “Collection Mode” (receive-only, no transmission)

4. Configure interface rate and duplex mode; auto-negotiation is recommended

5. Enable the “Hardware Timestamp” function to improve time precision

6. Configure an interface description noting the link name collected by this interface

7. Click Save; the interface status shows “Connected” and traffic values indicate normal collection

11.4.2 NetFlow/sFlow Collection Configuration

1. Navigate to [Collection Configuration] – [Flow Collection Configuration]

2. Click “Add Collection Device”

3. Configure network device information:

  • Device Name: Enter the router/switch name
  • Device IP: Enter the management IP of the network device
  • Flow Protocol Type: Select NetFlow V9/NetFlow V5/sFlow/IPFIX
  • Listening Port: Default is 9996 for NetFlow, 6343 for sFlow; can be modified based on actual configuration

4. Click Save; the system automatically starts listening on the corresponding port

5. Configure flow export on the network device side, pointing to the management IP and corresponding port of this equipment

6. After configuration, view the collection status; “Flow Data Received” indicates successful configuration

11.4.3 Collection Verification

1. Navigate to [Real-time Monitoring] – [Interface Traffic]

  • View the real-time traffic curve of the corresponding interface; numerical fluctuations indicate normal traffic collection

2. Navigate to [Real-time Monitoring] – [Session List] to check whether sessions are being generated

3. Compare with known link traffic to confirm the collected traffic volume matches expectations

4. If no traffic is collected, troubleshoot in the following order:

  • Check the physical link connection and interface indicator status
  • Check whether the switch mirror configuration is correct and the mirror direction is correct
  • Check whether the equipment interface mode is set to collection mode
  • Check whether the fiber optical power is within the normal range
  • Check whether collection filter rules have been configured that filter out all traffic

11.5 Storage Configuration

1. Navigate to [System Management] – [Storage Management]

2. View disk status, confirm all disks are recognized normally, and RAID status is normal

3. Configure the storage mode:

  • Circular Overwrite Mode: Automatically overwrites the oldest data when storage is full; suitable for continuous monitoring scenarios
  • Stop When Full Mode: Stops writing when storage is full; suitable for dedicated forensic scenarios

4. Configure storage threshold alarms: trigger an alarm when storage usage reaches the set percentage (e.g., 80%)

5. Configure data retention policies: set retention periods for statistical data, alarm logs, and raw packets

6. Enable the important data lock function, supporting manual locking of key time-period data

7. Click Save Configuration

11.6 Alarm Configuration

11.6.1 Alarm Threshold Configuration

1. Navigate to [Alarm Management] – [Threshold Alarm Configuration]

2. Configure interface bandwidth utilization alarms: set thresholds (e.g., 80%), duration, and alarm level

3. Configure abnormal traffic alarms: set per-IP traffic thresholds, new connection rate thresholds, etc.

4. Configure system resource alarms: CPU, memory, and disk usage alarm thresholds

5. Configure performance quality alarms: latency, packet loss rate, and retransmission rate alarm thresholds

6. Each alarm item can be independently enabled/disabled with adjustable sensitivity

11.6.2 Alarm Notification Configuration

Email Alarm Configuration

1. Navigate to [Alarm Management] – [Notification Configuration] – [Email]

2. Configure SMTP server address, port, sender account, and authorization code

3. Add recipient email addresses; multiple recipients can be configured

4. Select the alarm levels and types to be pushed

5. Click Test to verify email sending is normal

Syslog Alarm Configuration

1. Configure Syslog server address, port, and protocol (UDP/TCP)

2. Configure Syslog format and levels

3. Supports unified reporting of alarms and system logs to the log platform

SNMP Trap Configuration

1. Configure SNMP version, community name, and Trap server address

2. Supports integration with third-party network management platforms

11.7 Function Verification and Commissioning

After completing the basic configuration, verify and commission the core functions of the equipment to ensure proper operation.

11.7.1 Real-Time Monitoring Function Verification

1. Open [Real-time Monitoring] – [Traffic Overview] to view the network-wide traffic overview dashboard

2. Confirm all metrics display normally and data refreshes in real time

3. View Top Applications and Top IP rankings; data should match the actual network conditions

4. View interface traffic trend charts; curves should be smooth without abnormal jumps

11.7.2 Protocol Identification Verification

1. Navigate to [Application Analysis] – [Application Traffic Ranking]

2. View the identified application list, confirm mainstream applications are correctly identified

3. Select known application traffic to verify the identification results are accurate

4. For unidentified traffic, mark it and provide feedback to update the signature library

11.7.3 Retrospective Analysis Verification

1. Navigate to [Retrospective Analysis] – [Session Search]

2. Select a recent 1-hour time range and enter a known IP address for search

3. View the returned session list, confirm session information is complete and accurate

4. Click a session to view details, confirming session timing and packet information are correct

5. Click packet decode to confirm protocol parsing is detailed and accurate

6. Test exporting a pcap file, confirming normal export and the file can be opened in Wireshark

11.7.4 Alarm Function Verification

1. Trigger an alarm by constructing test traffic to verify alarm detection and notification functions

2. View the alarm list, confirm alarms are generated promptly and information is accurate

3. Verify alarm notification channels are normal; email and Syslog can receive notifications

4. Test alarm confirmation, clearing, and export operations to verify normal functionality

11.7.5 Report Function Verification

1. Navigate to [Report Center] – [Report Templates]

2. Select the daily report template to generate the current day’s traffic report

3. View the report content for completeness, data accuracy, and formatting quality

4. Test exporting in PDF and Excel formats to confirm normal operation

11.8 System Optimization Configuration

Based on the actual network environment and usage requirements, optimize the system configuration to improve operational efficiency and user experience.

11.8.1 Collection Policy Optimization

  • Traffic Filtering Configuration: For traffic that does not require analysis (such as inter-device internal heartbeat and backup traffic), configure collection filter rules to reduce invalid processing and storage usage
  • Packet Truncation Configuration: If only protocol headers need to be analyzed without full application content, configure packet truncation length (e.g., truncate to the first 256 bytes) to significantly save storage space
  • Sampling Ratio Configuration: For ultra-high bandwidth links, configure a sampling ratio to reduce processing load, balancing analysis precision and equipment performance

11.8.2 Baseline Learning Configuration

1. Navigate to [Security Analysis] – [Baseline Configuration]

2. Start baseline self-learning; a learning period of no less than 7 days is recommended

3. Set baseline sensitivity and adjust alarm trigger thresholds based on the network environment

4. Enable baseline alarms after the learning period ends; observe false positives for one week and optimize gradually

11.8.3 Custom IP Groups and Application Groups

1. Navigate to [Object Management] – [IP Group Management]

2. Create IP groups for server areas, office areas, production areas, etc., classified by department, region, and business system

3. Navigate to [Object Management] – [Application Group Management]

4. Create application groups for business applications, office applications, entertainment applications, etc.

5. After configuration, statistical analysis and alarm configuration can be performed by group to improve management efficiency

11.9 Commissioning Completion Confirmation

After all configuration and verification are completed, organize the configuration information and confirm the following items:

  • Equipment operates normally without hardware alarms
  • Traffic collection is normal with accurate and complete data
  • Core functions have passed verification and meet usage requirements
  • Alarm configurations are reasonable and notification channels are normal
  • User accounts and permission configurations are complete
  • Configurations have been saved and system time is accurate
  • Relevant documentation and configuration records have been archived

12.1 Installation Environment Precautions

  • The equipment must be installed in an indoor, ventilated, and dry environment; use in outdoor, humid, dusty, or corrosive gas environments is prohibited
  • The equipment operating environment temperature must be maintained between 5°C and 40°C; prolonged exposure beyond the temperature range will accelerate hardware aging, shorten equipment lifespan, and may even cause hardware damage
  • Avoid placing the equipment near heat sources such as heaters, air conditioner outlets, power amplifiers, etc.; avoid direct sunlight on the equipment
  • Sufficient heat dissipation space must be reserved around the equipment; strictly prohibit blocking the equipment air inlet and outlet; when rack-mounted, at least 1U of space must be reserved above and below
  • The equipment must be installed in a stable, secure position to avoid vibration and shock; rack installation must be firmly secured to prevent tipping
  • The equipment should be kept away from strong electromagnetic interference sources such as high-power motors, transformers, wireless transmitting equipment, etc., to avoid interference with normal equipment operation
  • The equipment room must have dust prevention measures and regular cleaning; dust accumulation can cause poor heat dissipation and poor contact

12.2 Power Usage Precautions

  • The equipment must use power cables and power modules with matching specifications; use of non-original accessories is prohibited
  • The power input voltage must be within the equipment’s rated range; in environments with unstable voltage, it is recommended to equip a voltage regulator
  • For redundant power supply models, connect to two independent power supply circuits to truly achieve power redundancy and avoid equipment shutdown due to single circuit disconnection
  • The equipment must be reliably grounded with a grounding resistance of ≤4Ω; removing the ground wire is prohibited to avoid static accumulation and lightning damage
  • Hot-plugging of power modules, fan modules, and other internal components other than hot-swappable parts is prohibited
  • Disconnect the power supply when the equipment is not used for extended periods to avoid standby losses and lightning risks
  • During thunderstorm weather, it is recommended to disconnect the equipment power and network cables to prevent induced lightning damage to the equipment
  • The power supply must be disconnected before cleaning the equipment; using wet cloths to wipe the equipment is prohibited; liquids must not enter the equipment interior

12.3 Interface and Wiring Precautions

  • The service collection interface is a unidirectional receive interface; connecting it to the normal service network to send data is prohibited; connecting PoE power-supplying switches is prohibited to avoid damaging the equipment interface
  • Protect the end faces of optical modules and fibers during insertion and removal; touching the optical port end faces with hands is prohibited to avoid dust contamination; contaminated fiber end faces must be cleaned with dedicated cleaning tools
  • The fiber bending radius must not be too small; sharp bends are prohibited to avoid fiber breakage and excessive optical power loss
  • Optical modules must match the fiber type: single-mode modules with single-mode fiber, multi-mode modules with multi-mode fiber; mixing is prohibited; rate and wavelength must match
  • Network cable termination must comply with standard specifications with correct wire sequence and reliable shield grounding to avoid packet loss caused by cable quality issues
  • When laying cables, avoid high-voltage power cables to prevent electromagnetic interference; power cables and signal cables must be laid separately with a spacing of ≥30cm
  • When inserting or removing interface cables, hold the connector part; pulling on the cable body is prohibited to avoid damage to interface pins and cable breakage
  • Random insertion or removal of service interface cables while the equipment is running is prohibited to avoid interrupting traffic collection

12.4 Operation and Usage Precautions

  • Safely keep the administrator account password and change passwords regularly; password settings must meet complexity requirements; weak passwords are prohibited
  • It is recommended to back up the configuration before modifying system configuration; save configurations promptly after modification to avoid loss due to power failure
  • For system upgrades, use officially released stable versions; disconnecting power or restarting the equipment during the upgrade process is prohibited to avoid system startup failure due to failed upgrade
  • Before deleting raw packet data, confirm it no longer needs to be retained; important data should be exported and backed up or locked in advance
  • Running unauthorized software on the equipment is prohibited; privately cracking the system or modifying system files is prohibited
  • Promptly troubleshoot and handle abnormal equipment alarms; ignoring alarms and running the equipment with faults for extended periods is prohibited
  • Before performing configuration operations that may affect services, report in advance and choose off-peak hours, and prepare rollback plans
  • Sending large volumes of test traffic to impact the collection port is prohibited, to avoid exceeding equipment processing capacity and causing packet loss or system abnormalities

12.5 Security and Compliance Precautions

  • Equipment deployment and usage must comply with applicable national laws and regulations; using the equipment for illegal network monitoring, stealing others’ information, or other illegal activities is prohibited
  • Traffic data contains sensitive information; data security protection must be implemented with strict access control; illegal disclosure and dissemination are prohibited
  • Processing of traffic data involving personal information must comply with the requirements of the “Personal Information Protection Law,” with proper data desensitization and permission control
  • In classified protection compliance scenarios, the retention period of equipment logs and traffic data must meet the corresponding level protection requirements, with retention of at least 6 months
  • Using the equipment to collect from unauthorized network links is prohibited; the collection scope must be within the legal network scope of the organization
  • Equipment operation and maintenance activities must maintain audit records; all operations must be traceable

12.6 Stored Data Precautions

  • Regularly check disk operating status and storage capacity; promptly address disk failures and insufficient capacity issues
  • Regularly back up important data to external storage media to avoid data loss due to disk damage
  • Before equipment disposal or return to factory for repair, thoroughly erase data on the disks to avoid data leakage
  • In circular overwrite mode, promptly lock or export specific event data that needs to be retained to avoid being overwritten by new data
  • Large-scale data export should be performed during off-peak hours to avoid affecting normal equipment analysis performance
  • External storage devices must be virus-scanned before connection to avoid virus infection of the equipment system

13.1 Routine Maintenance

13.1.1 Daily Inspection

During daily equipment operation, perform a routine inspection once per day, checking the following items and keeping records:

  • Equipment appearance and environment: Check for abnormal equipment appearance and whether the equipment room temperature and humidity are within normal ranges
  • Indicator status: Check the front panel power LED, running LED, alarm LED, and interface LED statuses are normal
  • System status: Log into the Web management interface to check CPU, memory, and disk usage are within normal ranges
  • Collection status: Check whether the traffic on each collection interface is normal without interruption
  • Alarm information: Check for new alarms and promptly handle unprocessed alarms
  • Time synchronization: Confirm the system time is accurate and NTP synchronization is normal

13.1.2 Weekly Maintenance

Perform in-depth maintenance once per week:

  • Disk status check: Enter the storage management page to check the health status of all disks, RAID status is normal, and no bad sector alarms
  • Log cleanup check: Check system log and alarm log storage; clean up expired logs
  • Configuration backup: Perform one system configuration backup and export the backup file for storage
  • Alarm review: Review the week’s alarm situation, analyze alarm causes, optimize alarm thresholds, and reduce false positives
  • Cable check: Visually inspect equipment cable connections for looseness or damage

13.1.3 Monthly Maintenance

Perform comprehensive maintenance once per month:

  • Equipment cleaning: Clean dust from the equipment surface and ventilation filters to maintain good heat dissipation
  • Performance evaluation: Compile the month’s equipment performance data, evaluate whether the equipment load is reasonable, and identify any performance bottlenecks
  • Data archiving: Archive and back up historical data requiring long-term retention to free storage space
  • Rule library upgrade: Check protocol signature library and attack rule library versions; upgrade to the latest versions promptly
  • System patch check: Check system security patches and firmware updates; evaluate upgrade necessity
  • Account audit: Audit system user accounts, clean up unused accounts, and verify the reasonableness of permission assignments

13.2 Periodic Maintenance

13.2.1 Quarterly Maintenance

Perform in-depth maintenance once per quarter:

  • Internal dust removal: With the power disconnected, open the equipment chassis and use an anti-static brush and vacuum cleaner to clean internal dust, focusing on heat sinks, fans, and circuit boards
  • Fan maintenance: Check fan operation, clean accumulated dust from fans, lubricate bearings, and replace fans with abnormal noise
  • Interface cleaning: Clean optical ports, electrical ports, and power interfaces to remove oxidation layers and ensure good contact
  • Cable arrangement: Organize cables in the cabinet, replace aged and damaged cables, and update labels
  • Grounding check: Check whether the equipment grounding is reliable; measure grounding resistance to ensure compliance

13.2.2 Annual Maintenance

Perform comprehensive maintenance and performance testing once per year:

  • Comprehensive hardware testing: Conduct full testing of CPU, memory, hard drives, power supply, fans, interfaces, and all other hardware to evaluate hardware health
  • Performance stress testing: Conduct stress testing to verify equipment processing performance meets standards and identify hidden faults
  • Power supply testing: Test power supply output voltage and ripple for normality; evaluate power supply aging level
  • Disk health testing: Use professional tools to detect disk bad sectors and remaining lifespan; replace unhealthy disks
  • Firmware upgrade: Upgrade the system to the latest stable version and upgrade all hardware firmware
  • Overall assessment: Issue the equipment annual operation report, evaluate remaining equipment service life, and provide upgrade and expansion recommendations

13.3 Fault Repair Process

13.3.1 Fault Reporting

When equipment faults cannot be resolved by the user, report for repair according to the following process:

1. Fault recording: Record detailed fault symptoms, fault occurrence time, operations before the fault, equipment model, serial number, and other information

2. Preliminary troubleshooting: Perform preliminary troubleshooting according to the common fault troubleshooting methods in Chapter 14 to rule out simple faults

3. Contact after-sales: Call our technical support hotline +86 13538869979 or contact the assigned sales engineer

4. Information provision: Provide technical support personnel with detailed fault information, equipment information, and on-site environment; cooperate with remote troubleshooting

5. Remote assistance: Technical support personnel can troubleshoot faults through remote assistance; users must cooperate by providing remote access conditions

13.3.2 Fault Classification and Response

Our company provides classified response based on fault severity and impact scope:

  • Level 1 Fault (Emergency): Complete equipment downtime, complete service interruption, core function failure. Response time: response within 2 hours, on-site within 4 hours in urban areas, on-site within 24 hours for remote locations
  • Level 2 Fault (Important): Partial function failure, severe performance degradation, local service impact. Response time: response within 4 hours, on-site within 8 hours on working days
  • Level 3 Fault (General): Local function abnormality, minor performance issues, no impact on core services. Response time: response within 1 working day, resolve through remote assistance
  • Level 4 Fault (Consultation): Function consultation, configuration guidance, usage questions. Response time: reply within 2 hours on working days

13.3.3 Return to Factory Repair

For return-to-factory repairs, follow the following process:

1. After the technical support engineer confirms that return-to-factory repair is required, issue a repair order

2. The user backs up important data in the equipment and erases sensitive information

3. Use the original packaging to properly package the equipment to avoid transportation damage

4. Ship back to the designated address and keep the logistics tracking number

5. Our company inspects and repairs the equipment upon receipt, and tests after repair completion

6. After repair, ship the equipment back to the user with a repair report attached

7. The user inspects and confirms acceptance upon receipt, completing the repair process

13.4 Warranty Policy

  • Warranty Period: The equipment provides a three-year free warranty for the complete unit, calculated from the date of equipment delivery and acceptance
  • Warranty Scope: During the warranty period, hardware faults and software faults caused by equipment quality issues are provided with free repair and replacement services
  • Warranty Exclusions: The following situations are not covered by the free warranty:
  • Damage caused by human factors or improper use
  • Damage caused by force majeure (floods, fires, lightning strikes, earthquakes, etc.)
  • Damage caused by unauthorized disassembly, modification, or repair
  • Faults caused by use of non-original accessories
  • Normal appearance wear and tear of the equipment
  • Warranty Service Method: During the warranty period, telephone technical support, remote technical support, and return-to-factory repair services are provided; on-site service is available in core cities
  • Extended Warranty Service: After the warranty period ends, extended warranty services can be purchased to continue enjoying original factory warranty services

13.5 Component Replacement Precautions

  • Equipment component replacement should be performed by factory-authorized engineers; private disassembly and replacement are prohibited
  • Replacement components must be genuine original factory parts; third-party compatible parts are prohibited to avoid equipment faults and safety hazards
  • Hot-swappable components (power supplies, fans) can be replaced while the equipment is running but must comply with standard operating procedures to avoid short circuits
  • Before replacing hard drives, confirm data has been backed up; after RAID array replacement, wait for the rebuild to complete
  • When replacing optical modules, pay attention to electrostatic protection and avoid gold finger contamination
  • After component replacement, functional testing must be performed to confirm normal equipment operation

13.6 Equipment Storage and Transportation

  • For long-term equipment storage, place it in the original packaging and store in a dry, ventilated environment at temperatures between -20°C and 60°C
  • During storage, power on the equipment once every three months, each time for no less than 2 hours, to prevent component damage from moisture
  • For equipment transportation, original factory packaging must be used with adequate cushioning protection to avoid severe vibration and collision
  • During transportation, avoid rain, direct sunlight, and heavy pressure; placing upside down or rolling is prohibited
  • Handle equipment gently when loading and unloading; throwing is prohibited

14.1 Common Hardware Faults

14.1.1 Equipment Cannot Power On, Power LED Not Lit

Possible Causes:

  • Power cable poor contact or damage
  • Power outlet has no power or switch is off
  • Power module failure
  • Internal power switch of the equipment is not turned on
  • Internal short circuit protection triggered

Troubleshooting Steps:

1. Check whether the power outlet has power and the outlet switch is on; verify by connecting another electrical device

2. Check whether both ends of the power cable are firmly inserted; try replacing with another power cable

3. Check whether the power switch on the equipment rear panel is set to the ON position

4. For redundant power supply models, try replacing with the other power module for testing

5. Disconnect all interface cables, connect only power, and attempt to power on

6. If the above operations are ineffective, determine it as a power supply or motherboard hardware fault and contact after-sales repair

14.1.2 Running LED Not Lit After Power-On, System Cannot Start

Possible Causes:

  • System firmware corruption
  • Memory failure
  • Motherboard failure
  • Storage system failure causing boot failure

Troubleshooting Steps:

1. Restart the equipment, observe the indicator states during startup, and record abnormal phenomena

2. Connect the Console port and view the startup log output to locate where startup fails

3. Attempt to restore factory settings or reflash the system firmware

4. If it is a hardware fault, contact after-sales repair

14.1.3 Interface LED Not Lit, Physical Connection Failure

Possible Causes:

  • Cable fault or poor contact
  • Optical module fault or mismatch
  • Peer device interface fault or not enabled
  • Local interface configuration error or hardware fault
  • Fiber optic power too low or too high

Troubleshooting Steps:

1. Check whether the cable is firmly inserted; reinsert once

2. Test by replacing with a known-good cable

3. For optical ports, check whether the optical module is fully seated; test by replacing the optical module

4. Verify whether the peer device interface is properly enabled and the rate/duplex configuration matches

5. Use an optical power meter to measure the fiber transmit/receive optical power and confirm it is within the optical module receiving range

6. Check whether the equipment interface is disabled and whether the rate mode configuration is correct

7. Connect the cable to another normal interface to determine whether it is an interface hardware fault

14.1.4 Equipment Restarts Frequently During Operation

Possible Causes:

  • Unstable power supply
  • Equipment overheat protection
  • Memory failure
  • System software bug
  • Power module failure

Troubleshooting Steps:

1. Check whether the supply voltage is stable and whether power interruptions followed by recovery occur

2. Check whether equipment ventilation is good, whether the air inlet and outlet are blocked, and measure whether the equipment surface temperature is too high

3. View system logs to record the system state and alarm information before the restart

4. Upgrade the system to the latest version to rule out software issues

5. For redundant power supply models, test whether single power supply operation is normal

6. If the problem persists, contact after-sales to test the hardware

14.1.5 Alarm LED Steadily Lit

Possible Causes:

  • Power supply failure
  • Fan failure
  • Disk failure
  • Temperature too high
  • Storage capacity full

Troubleshooting Steps:

1. Log into the Web management interface, navigate to [System Management] – [System Status], and view hardware alarm information

2. View specific alarm content and address accordingly

3. Power alarm: Check whether the power module is firmly seated; replace the power module

4. Fan alarm: Check whether the fan has stopped; clean fan dust; replace the faulty fan

5. Disk alarm: Check disk status; replace the faulty disk; rebuild RAID

6. Temperature alarm: Clean ventilation openings; improve the equipment room ambient temperature

7. Storage alarm: Clean up storage space; expand storage

14.2 Common Collection Faults

14.2.1 No Traffic Data on Collection Interface

Possible Causes:

  • Physical link failure
  • Mirror source configuration error, no traffic mirrored
  • Interface mode configuration error
  • Collection filter rules filtering all traffic
  • Optical power too low to identify signals

Troubleshooting Steps:

1. Check the interface indicator status to confirm the physical connection is normal

2. Check the switch mirror configuration: confirm the mirror source is correct, mirror direction is correct, and destination port is correct

3. Connect a computer to the switch mirror destination port and use Wireshark to capture packets; confirm whether mirrored traffic is being output

4. Check the equipment interface configuration to confirm the interface mode is “Collection Mode” and is not disabled

5. Check collection filter rules; temporarily disable all filter rules and observe whether traffic appears

6. For optical port scenarios, measure the optical power to confirm it is within the normal range

7. Test with other collection interfaces on the equipment to rule out interface hardware faults

14.2.2 Collected Traffic Volume Does Not Match Actual, Significantly Lower

Possible Causes:

  • Only single-direction traffic mirrored
  • Switch mirror port experiencing congestion and dropping packets
  • Sampling collection configured
  • Collection filter rules exist
  • Equipment processing capacity insufficient causing packet loss

Troubleshooting Steps:

1. Check the switch mirror configuration to confirm bidirectional mirroring is configured

2. View switch mirror port statistics to check for discarded packets

3. Check the equipment collection configuration to confirm sampling mode is not enabled

4. Check collection filter rules to confirm important traffic is not being filtered

5. Check equipment CPU and memory usage to confirm no performance overload

6. Compare with the peer interface traffic statistics, calculate the deviation ratio, and locate the problem point

14.2.3 No NetFlow/sFlow Data

Possible Causes:

  • Network device flow export not configured
  • Flow export destination IP or port misconfigured
  • Network connectivity issues, flow data cannot reach the equipment
  • Firewall blocking the flow protocol port
  • Flow collection listening not enabled on the equipment side

Troubleshooting Steps:

1. Check the network device-side flow export configuration; confirm the destination IP is the equipment management IP and the port is correct

2. Test connectivity with the equipment management IP from the network device

3. Check whether the intermediate firewall allows the corresponding UDP port

4. Check the equipment-side flow collection configuration; confirm listening is enabled and the port matches

5. Capture packets on the equipment management port to confirm whether flow protocol packets are received

6. Check whether the flow protocol version matches and whether the equipment supports that version

14.3 Common Functional Issues

14.3.1 Inaccurate Application Identification with Large Amounts of Unknown Traffic

Possible Causes:

  • Protocol signature library version is outdated
  • Traffic is encrypted and cannot be deeply identified
  • Private protocols or niche applications not in the signature library
  • Packet truncation causing signature loss
  • Traffic passing through tunnel encapsulation, inner layers not parsed

Solutions:

1. Upgrade the protocol signature library to the latest version

2. For encrypted traffic, improve identification rates through SNI/behavioral analysis methods

3. Customize private protocol signatures and add them to the identification rules

4. If packet truncation is configured, increase the truncation length or disable truncation

5. Configure tunnel protocol parsing to identify inner-layer traffic

6. Contact technical support to submit unknown application samples to assist in updating the signature library

14.3.2 Slow Retrospective Search

Possible Causes:

  • Query time range too large
  • Query conditions too broad
  • System load too high
  • Disk I/O performance bottleneck
  • Index corruption

Solutions:

1. Narrow the query time range and perform segmented queries

2. Add more query conditions to narrow the search range

3. Avoid large data queries during business peak hours

4. Check system resource usage and close unnecessary tasks

5. Rebuild the data index

6. For large-capacity storage scenarios, consider upgrading to SSD storage to improve search performance

14.3.3 Excessive False Alarm Rate

Possible Causes:

  • Alarm threshold settings unreasonable
  • Baseline learning insufficient
  • Normal fluctuations in network traffic
  • Rule matching overly sensitive

Solutions:

1. Adjust alarm thresholds based on actual network conditions, appropriately raising trigger conditions

2. Extend the baseline learning period to allow the model to fully learn normal traffic patterns

3. Configure alarm suppression and aggregation to reduce duplicate alarms

4. Add whitelist entries to exempt normal business traffic from alarming

5. Optimize detection rules to reduce sensitivity

6. Regularly review alarms and continuously optimize alarm strategies

14.3.4 Unable to Log into Web Management Interface

Possible Causes:

  • Management network not working
  • Equipment IP address conflict
  • Browser compatibility issue
  • Service abnormality
  • Incorrect account or password

Troubleshooting Steps:

1. Test connectivity with the equipment management IP from the computer using ping

2. Check for IP address conflicts

3. Try a different browser; use the latest version of Chrome or Firefox

4. Clear browser cache and access using incognito mode

5. Confirm the account and password are correct, paying attention to case sensitivity

6. If the password is forgotten, reset the password through the Console port

7. Restart the equipment Web service or restart the equipment

14.4 Common Storage Issues

14.4.1 Disk Usage Growing Too Quickly

Possible Causes:

  • Traffic volume is higher than expected
  • Packet truncation not configured, full-capture storage consumes excessive space
  • Retention period configured too long
  • Abnormal high-volume traffic present
  • Statistics data and logs not automatically cleaned up

Solutions:

  • Assess actual traffic and configure packet truncation as needed, which can significantly reduce storage consumption
  • Adjust data retention period, shorten raw packet retention time
  • Configure storage tiering strategy to migrate historical data to high-capacity storage
  • Check for abnormal traffic and confirm whether it is legitimate business traffic
  • Configure automatic log cleanup policies to periodically purge expired logs
  • If storage capacity is genuinely insufficient, consider expanding hard drives

14.4.2 Disk Fault Alarm

Possible Causes:

  • Physical disk damage
  • Poor disk contact
  • RAID array degraded

Resolution Methods:

  • Navigate to the storage management page to identify which specific disk has failed
  • For hot-swappable drives, remove the faulty disk, reinsert it, and observe if it recovers
  • If the disk is confirmed damaged, replace it promptly with a new drive of the same specifications
  • After replacement, the system will automatically begin RAID reconstruction; wait for it to complete
  • Device performance may degrade during reconstruction; it is recommended to perform operations during off-peak business hours
  • Back up important data in advance to prevent data loss from multiple disk failures

14.4.3 Unable to Export pcap Data

Possible Causes:

  • Export data volume too large, timeout failure
  • Insufficient storage space, unable to generate export file
  • Browser download restrictions
  • Insufficient permissions

Solutions:

  • Narrow the export scope and export in multiple batches
  • Check remaining system storage space to ensure sufficient space for temporary files
  • Use direct browser downloads to avoid download manager interception
  • Confirm the logged-in account has data export permissions
  • Use external USB drive for export, suitable for large file export scenarios

Chapter 15 Product Q&A

Q1: What is the difference between a Network Traffic Analysis (NTA) device and an Internet Behavior Management (IBM) device?

A: The two have different positioning and significantly different core capabilities:

  • Different positioning: Traffic analysis devices focus on network operations, performance analysis, fault troubleshooting, and security forensics — they are comprehensive tools for both operations and security. Internet behavior management focuses on user internet behavior control and auditing, with the core purpose being management and auditing.
  • Different collection methods: Traffic analysis devices are typically deployed out-of-band (passively), do not insert into the business path, and do not affect network topology or performance. Internet behavior management devices are typically deployed in-line, with all traffic passing through the device, posing a single point of failure risk.
  • Different analysis depth: Traffic analysis devices support full-capture traffic replay and packet-level deep analysis, capable of identifying root causes. Internet behavior management devices focus on statistical auditing at the user and application level, with coarser analysis granularity.
  • Different functional focus: Traffic analysis devices excel in fault troubleshooting, performance analysis, and security forensics. Internet behavior management devices excel in access control, application blocking, and behavior auditing.

Q2: Will an out-of-band deployed traffic analysis device affect the existing network business?

A: No. An out-of-band deployed traffic analysis device only receives mirrored or optical-split copied traffic. It does not transmit data itself, is not inserted into the business path, and does not participate in business data forwarding in any way. Even if the device loses power, fails, or is removed, it will have zero impact on the existing network — business continues without interruption. This is the core advantage of out-of-band deployment.

Q3: How long can full traffic data generally be stored? What happens when storage is full?

A: Storage duration depends on link bandwidth, average packet length, storage capacity, and storage policies. Taking a 10Gbps link with an average packet size of 512 bytes and full-capture storage as an example: 8TB storage can hold approximately 2–3 days of data, and 32TB can hold approximately 8–12 days. If packet truncation is configured (e.g., truncating to 256 bytes), storage duration can be doubled.

The device defaults to circular overwrite mode — when storage is full, the oldest historical data is automatically overwritten, always preserving the most recent data. If long-term retention of specific data is required, you can manually lock important time periods or export backups.

Q4: Can the device identify encrypted traffic? Can it decrypt HTTPS?

A: The device supports encrypted traffic identification but does not decrypt traffic content by default. By parsing plaintext fields in the TLS handshake phase (such as SNI server names, certificate information) along with traffic behavior characteristics, the device identifies the application and service type corresponding to encrypted traffic, enabling application classification and anomaly detection without decryption.

If HTTPS content decryption is required for deep analysis, it can be used in conjunction with an SSL decryption device or proxy device, where decrypted traffic is fed to the analysis device. However, decryption involves compliance and privacy issues and must be conducted within a legal and compliant framework.

Q5: How many IP addresses can the device monitor simultaneously? Is there a node limit?

A: The device has no IP node limit. As long as traffic passes through the collection link, it can be analyzed and statistically processed. The core limits are processing bandwidth and concurrent session count. As long as bandwidth and sessions remain within device specifications, any number of IP addresses can be monitored.

Q6: Can the device monitor networks of multiple geographically distributed branch offices?

A: Yes. There are two implementation approaches:

  • Flow Collection Approach: Enable NetFlow/sFlow on branch routers and send flow data over the WAN to the headquarters traffic analysis platform for unified monitoring. This approach uses low bandwidth and has low cost.
  • Distributed Probe Approach: Deploy small probe devices at each branch for local collection and analysis, reporting analysis results to the headquarters platform. When deep analysis is needed, raw probe data can be retrieved. This approach provides deeper analysis.

Q7: How does the device integrate with my existing operations platform/security platform?

A: The device provides rich, standardized northbound interfaces supporting integration with third-party platforms:

  • RESTful API Interface: Full-featured API allowing third-party platforms to retrieve traffic data, alarm data, statistical reports, etc.
  • Syslog Interface: Supports reporting system logs and alarm logs to log platforms and SIEM platforms in standard Syslog format.
  • SNMP Interface: Supports SNMP V2/V3, can be integrated into traditional network management platforms to monitor device operating status.
  • Kafka Interface: Supports high-performance data push, suitable for big data platform integration.
  • Alarm Action Interface: Supports integration with firewalls, EDR, and other devices to enable automatic blocking after threat detection.

Q8: Does device deployment require changes to the existing network? Will it cause network outages?

A: This depends on the collection method:

  • Port Mirroring: Only requires configuring mirror commands on switches — software configuration, no physical cabling changes needed, no network outage.
  • Optical Splitter: Requires disconnecting fiber to insert the splitter, resulting in a brief link interruption. The interruption duration depends on operational speed, typically under 1 minute. Recommended during off-peak business hours.
  • Flow Collection: Only requires configuring flow export commands on network devices — does not affect business and does not cause network outages.

Q9: How are the device’s DPI signature libraries updated? Is there a fee?

A: The protocol signature library and attack rule library support online automatic updates, or manual downloads of upgrade packages for local installation. During the warranty period, signature library upgrade services are free. After the warranty period, you can purchase signature library upgrade services for continued updates. Our company continuously tracks new protocols, applications, and emerging attacks, regularly updating the signature libraries to maintain identification capabilities.

Q10: In the context of cybersecurity classified protection (MLPS/Classified Protection) construction, what requirements can the traffic analysis device satisfy?

A: The traffic analysis device supports multiple requirements in MLPS 2.0:

  • Network Audit Requirements: Full retention of network access logs, recording source/destination IP, ports, time, applications, access content, etc., with a retention period meeting the 6+ month requirement.
  • Intrusion Prevention Requirements: Detecting network attacks, identifying abnormal traffic and intrusion attempts, and providing timely alerts.
  • Data Integrity and Confidentiality: Monitoring abnormal data exfiltration behavior and identifying data leakage risks.
  • Centralized Management Requirements: Providing unified traffic monitoring and security posture visualization to support security management center construction.
  • Traceability: Full-capture traffic replay capability for source tracing and evidence collection after security incidents.

Q11: Does the device support IPv6?

A: Full IPv6 support. The device supports IPv4/IPv6 dual-stack parsing, can identify IPv6 traffic, and supports all functionality over IPv6 including session statistics, protocol parsing, performance analysis, and anomaly detection — adaptable to IPv6 network deployment requirements.

Q12: Can one device monitor multiple links simultaneously?

A: Yes. The device provides multiple collection interfaces, each capable of receiving mirrored traffic from one link, with independent analysis on multiple links simultaneously. Statistics can be displayed separately by interface. As long as total traffic does not exceed the device’s maximum processing bandwidth, multiple links can be monitored simultaneously.

Q13: Can the device be deployed in-line directly in the link?

A: Not recommended. The standard form of this device is an out-of-band analysis device, designed and positioned for passive collection and analysis. It does not have traffic forwarding or control functions. If you require in-line traffic management devices, please consider our traffic scrubbing or application delivery product series.

Q14: After a data center power outage, will the device automatically restart when power returns?

A: Yes. The device has power-restore auto-on by default — when power returns, the system will start automatically without manual intervention, ensuring continuous operation in unattended scenarios. This feature can also be disabled in the BIOS if needed.

Q15: Is the device data secure? Will it upload data to the cloud?

A: All data is stored locally. By default, no data is uploaded to external servers or the cloud. Device upgrades and signature library updates only connect to the official upgrade server when manually triggered or when automatic updates are configured, to download upgrade packages — never uploading user business data. Users have full control over their data, satisfying data localization requirements for high-security-level scenarios.

Chapter 16 Product Acceptance

16.1 Acceptance Basis

Device acceptance is conducted strictly in accordance with:

  • Purchase contract and technical agreement
  • Technical parameters and functional requirements specified in this manual
  • Relevant national and industry standards and specifications
  • Design plans and configuration lists confirmed by both parties

16.2 Acceptance Conditions

Acceptance work requires the following preconditions:

  • Device installed in position as required, wiring completed, environment compliant with operational requirements
  • Device powered on and debugged successfully, system operating normally
  • Traffic collection path fully deployed, capable of normal business traffic collection
  • Management network deployed, device accessible
  • Seller’s technical personnel have completed on-site installation, commissioning, and training
  • Buyer has personnel, tools, and environment necessary for acceptance testing

16.3 Acceptance Content and Standards

16.3.1 Appearance and Configuration Acceptance

Acceptance Item Acceptance Content Acceptance Standard
Device appearance Check for damage, deformation, scratches, and completeness of accessories Device in perfect condition, accessories complete, matches packing list
Model and specification Verify device model, serial number, hardware configuration Consistent with contract agreement
Installation quality Check installation firmness, levelness, cable organization Installed firmly and correctly, cables neatly organized with clear labels
Environmental conditions Check data center temperature/humidity, power supply, grounding Complies with device operating environment requirements

16.3.2 Hardware Performance Acceptance

Acceptance Item Acceptance Content Acceptance Standard
Power-on startup Power on device, check startup process Normal startup, startup time meets nominal value
Hardware status Check CPU, memory, disk, power supply, fan status All hardware operating normally, no alarms
Interface test Test physical connectivity of all interfaces All interfaces working properly, indicator light status correct
Redundancy test Redundant power supply, redundant fan testing Device operation uninterrupted with single component failure
Stability test Device continuously operating for 72 hours Stable operation, no abnormal restarts or crashes

16.3.3 Traffic Collection Acceptance

Acceptance Item Acceptance Content Acceptance Standard
Collection connectivity Inject test traffic, verify collection normal Interfaces show traffic, session list has data
Collection accuracy Compare with standard meter traffic values Traffic statistics deviation ≤5%
Line-rate capture test Test packet loss rate under full bandwidth traffic Packet loss rate ≤0.001%
Timestamp precision Test packet timestamp precision Precision meets nominal value
Multi-protocol support Test identification of multiple protocol traffic All mainstream protocols correctly identified

16.3.4 Functional Acceptance

Acceptance Item Acceptance Content Acceptance Standard
Real-time monitoring Verify traffic overview, interface monitoring, Top rankings, etc. Functions normal, data refreshes in real time
Traffic replay analysis Verify multi-condition search, session details, packet decoding, export functions Accurate search, detailed decoding, normal export
Performance analysis Verify latency, packet loss, retransmission performance metric statistics Metrics calculated accurately, display complete
Application recognition Verify application identification and classification statistics Recognition rate ≥95%, accurate classification
Alarm functions Verify threshold alarms, anomaly detection, notification push Alarms accurate and timely, notification channels normal
Reporting functions Verify report generation and export functions Report content complete, format correct
Management functions Verify user management, configuration management, upgrade/backup Functions complete and usable

16.3.5 Software and Documentation Acceptance

Acceptance Item Acceptance Content Acceptance Standard
Software version Check system software version and signature library version Latest official version, release date within 3 months before delivery
License information Check software license period, functional authorization, node license quantity Fully consistent with contract agreement, all function modules activated and usable, no functional restrictions
Technical documentation Check manual, certificate of conformity, warranty card, packing list, factory inspection report, authorization documents and other accompanying materials Complete and intact, accurate content, version matching physical items, valid official seals

16.3.6 Interface and Integration Acceptance

Acceptance Item Acceptance Content Acceptance Standard
Northbound interface availability Test connectivity and call correctness of RESTful API, Syslog, SNMP V2/V3, Kafka interfaces Interfaces respond normally, returned data format meets official specification, stable integration with third-party operations and security platforms
Data integration accuracy Verify consistency between interface-output traffic statistics, alarm event data and device local data Data accuracy rate ≥99%, no data loss, field omissions, or time deviation
Alarm action testing Test alarm-triggered push mechanism to third-party platforms Alarms pushed to target platform in real time, alarm level, time, description and other information complete, push latency ≤10 seconds
Third-party platform adaptation Verify compatibility with mainstream operations platforms, SIEM platforms, log platforms Data exchange and functional integration achievable, no compatibility issues

16.4 Acceptance Test Methods

16.4.1 Appearance and Configuration Verification Method

Combining visual inspection, nameplate verification, and system hardware information queries, the device body, accessories, and documentation are checked item by item against the purchase contract and packing list to ensure delivered items fully match the agreement. Hardware configuration information is queried via the device web management interface at [System Management] – [Device Information] page, including CPU model, core count, memory capacity, disk quantity and total capacity, interface quantity and types, and other key parameters. Command-line tools are also used to cross-verify underlying hardware identification information to prevent inflated specifications.

16.4.2 Function-by-Function Verification Method

Following the product function list, scenario-based operational verification is performed module by module across basic configuration, traffic collection, real-time monitoring, traffic replay analysis, performance statistics, security alarms, report management, and system management. Daily operations workflows are simulated, recording each function’s operational status and effectiveness, confirming all functions work properly and meet technical requirements. The verification process must cover the user’s core business scenarios to ensure practical usefulness and adaptability.

16.4.3 Traffic Comparison Test Method

A standard network tester is used to generate test traffic with known characteristics. A high-precision optical splitter simultaneously feeds both a standard meter and the device under test, comparing traffic statistics results and calculating statistical deviation rates. Tests use different packet lengths of 64 bytes, 128 bytes, 512 bytes, 1518 bytes, and 9600-byte jumbo frames, at different load levels including line-rate, 50% bandwidth, and 10% bandwidth, conducting multiple parallel test groups to verify collection accuracy and packet loss metrics across all scenarios.

16.4.4 Stress Stability Test Method

Under full-bandwidth nominal load, the device runs continuously for 72 hours. Core metrics including CPU utilization, memory utilization, disk write rate, concurrent session count, and packet loss rate are collected every 10 minutes, forming a complete stress test curve. During the test, the device must not experience restarts, crashes, abnormal process exits, excessive packet loss, or memory leaks. All performance metrics must remain stable within nominal ranges, with fluctuation not exceeding 10%.

16.4.5 Redundancy Reliability Test Method

For models with redundant power supplies and redundant fans, single-component hot-swap testing verifies redundancy failover protection capability: with the device running at full load, one power module is removed to verify uninterrupted device operation and normal hardware alarm triggering; reinserting the power module verifies automatic power recovery and alarm clearing, with no business collection interruption. The same method tests fan redundancy and disk RAID redundancy failover/recovery capabilities, confirming single-point failures do not affect business operations.

16.5 Acceptance Workflow

16.5.1 Acceptance Application

After device installation and commissioning are complete and the seller’s on-site technical personnel pass a continuous 72-hour self-inspection, the seller submits a written acceptance application to the buyer’s project manager, accompanied by the acceptance plan, self-inspection report, technical documentation list, factory inspection report, and other supporting materials. Both parties coordinate to determine the specific acceptance time and participants.

16.5.2 Forming the Acceptance Team

Acceptance work is led by the buyer, with a dedicated acceptance team formed comprising the buyer’s network operations personnel, information security personnel, project manager, and the seller’s on-site technical support engineers. For major projects, third-party supervision or evaluation organizations may be invited to participate throughout. The acceptance team is responsible for executing tests according to the acceptance plan, accurately recording results, and jointly issuing acceptance opinions.

16.5.3 On-site Acceptance Testing

The acceptance team conducts on-site tests item by item according to acceptance content and standards, completing acceptance test record forms, preserving screenshots and printouts of key interfaces and data during testing, and retaining on-site photos of hardware status and wiring workmanship. Issues found during acceptance are reported on-site, with both parties jointly confirming the phenomenon, impact scope, and severity level, and recording them with signatures.

16.5.4 Issue Rectification and Re-verification

If non-conformities are found during acceptance, the seller’s technical personnel issue a rectification plan on-site, specifying the rectification timeline, measures, and responsible persons. After buyer confirmation, rectification proceeds. Upon completion, the seller submits a rectification report and re-test data, applying for dedicated re-verification. Re-verification only covers the rectified items without repeating the full acceptance process.

16.5.5 Signing Acceptance Documents

After all acceptance items pass and all issues are closed out, both parties jointly sign the formal acceptance report with official seals — one original for each party. This serves as the legally valid document marking project delivery completion and the start of the warranty period.

16.6 Acceptance Conclusion Determination Standards

16.6.1 Acceptance Pass Criteria

When ALL of the following conditions are met simultaneously, the acceptance team may judge acceptance as passed:

  • All appearance and configuration items consistent with contract agreement, no missing or physically damaged equipment/accessories
  • All hardware metrics meet nominal standards, device operating stably, no hardware alarms
  • Traffic collection accuracy meets acceptance standards, packet loss rate ≤0.001% at line-rate full load
  • All functional modules operating normally, core business scenario verification passed, meeting actual user needs
  • Technical documentation complete, northbound interfaces and third-party platform integration compliant
  • No anomalies throughout the 72-hour stability test, system resource usage within reasonable range

16.6.2 Acceptance Failure Criteria

If ANY of the following occurs, acceptance is directly judged as FAILED:

  • Device model or core hardware configuration seriously inconsistent with contract, and cannot be rectified to meet requirements
  • Serious hardware failure — device cannot power on normally or core collection functions are inoperative
  • Traffic collection accuracy seriously substandard — deviation exceeds 15% at full load, with obvious packet loss
  • Core function modules largely inoperative — device cannot achieve the basic purpose of traffic collection and analysis
  • Major security risks or violations of national mandatory standards or industry regulations

16.6.3 Rectification-within-Deadline Criteria

For issues that do not affect core usage — such as non-core functional flaws, minor metric deviations, or missing documentation — the judgment is rectification-within-deadline, and acceptance pass opinions are temporarily withheld. The seller may complete rectification within the agreed period and apply for re-verification. After re-verification passes, acceptance documents are signed. During rectification, the device may be connected for trial operation, allowing users to start familiarization early.

16.7 Handling Rules for Outstanding Acceptance Issues

  • Issue Classification Mechanism: Outstanding acceptance issues are classified into three levels: critical, general, and minor. Critical issues refer to hardware or software failures affecting core functions that prevent normal business use. General issues refer to defects affecting secondary functions without impacting core business use. Minor issues refer to UI display, text description, or user experience optimization items.
  • Rectification Timeline: Critical issues shall be rectified within 7 working days in principle; general issues within 15 working days; minor issues may be included in the next version upgrade for unified resolution rather than separate on-site rectification.
  • Rectification Verification Process: After rectification is complete, the seller submits a formal rectification explanation and self-test report to the buyer. The buyer arranges operations personnel to conduct functional verification, confirms issues are fully resolved, signs re-verification opinions, and files them in the acceptance archive.
  • Dispute Resolution: If disputes arise between both parties regarding acceptance results, friendly negotiation is prioritized. If negotiation fails, both parties may jointly commission a qualified third-party authoritative testing organization for arbitration testing, with testing costs borne by the liable party.

16.8 Trial Operation and Final Acceptance

16.8.1 Trial Operation Period

After preliminary acceptance passes, the device formally enters a 30-day trial operation period. During this period, the device operates in the real production environment, with the buyer’s operations personnel performing daily operations and business adaptation, comprehensively verifying device stability, functional adaptability, and value under real business traffic. The seller provides 7×24 technical support during the trial period, responding to issues within 1 hour and promptly handling various faults and requirements that arise.

16.8.2 Final Acceptance Initiation Conditions

After the trial period concludes, final acceptance may be initiated when the following conditions are met:

  • Device operated stably during trial period, no serious failures causing business interruption
  • All outstanding issues from the preliminary acceptance phase fully rectified and verified
  • Device functions and performance meet actual business needs, achieving expected construction goals
  • Buyer’s operations personnel have mastered daily operations, configuration management, and basic fault troubleshooting skills
  • All technical documentation, management accounts, and license files fully transferred

16.8.3 Warranty Period Commencement

From the date of final acceptance pass, the device officially enters the contracted warranty period, with comprehensive after-sales services provided in accordance with national regulations and contract warranty terms. During the warranty period, the seller provides free phone technical support, remote technical support, fault repair, spare parts replacement, signature library upgrades, and door-to-door repair services in core cities.

Chapter 17 SEO Keywords and Optimization Tag System

17.1 Search Keyword Classification and Layout

17.1.1 Core Primary Keywords

Network Traffic Analysis Device, Full Capture Traffic Analysis Device, NTA Traffic Analysis Device, Network Traffic Monitoring Device, Network Traffic Collection & Analysis System

17.1.2 High Conversion Long-Tail Keywords

Network Traffic Analysis Device Manufacturer, Network Traffic Analysis Device Installation & Commissioning, Enterprise-Grade Network Traffic Analysis Device, Data Center Network Traffic Analysis Device, Full Capture Traffic Replay Analysis Device, Out-of-Band Deployed Traffic Analysis Device, 10-Gigabit Network Traffic Analysis Device, MLPS-Compliant Traffic Audit Device

17.1.3 Industry Traffic Keywords

Network Traffic Monitoring System, Network Behavior Analysis Device, Network Performance Analysis Device, Network Security Traffic Analysis, Data Center Traffic Analysis Device, Industrial Network Traffic Analysis, WAN Traffic Monitoring, Internet Egress Traffic Analysis, Network Fault Troubleshooting Device, DDoS Attack Detection Device

17.1.4 Brand-Specific Keywords

KITOZER Network Traffic Analysis Device, LA-NTA Traffic Analysis Device, KITOZER Full Capture Traffic Analysis, KITOZER Data Center Traffic Monitoring Device, KITOZER NTA Device Manufacturer

17.1.5 Dropdown/Related Search Keywords

How to install network traffic analysis device, Network traffic analysis device wiring method, Network traffic analysis device debugging tutorial, Network traffic analysis device brands, Network traffic analysis device working principle, Network traffic analysis device technical parameters, Network traffic analysis device application scenarios, Network traffic analysis device common faults

17.2 SEO Optimization Tag System

17.2.1 Page Core Optimization Tags

  • Page theme: Network Traffic Analysis Device Installation, Wiring & Commissioning Manual
  • Core keyword density: Core keywords distributed evenly throughout the document chapters, naturally integrated without keyword stuffing, density controlled at 2%–3%
  • Content value: Covers full lifecycle knowledge of product selection, principles, installation, wiring, commissioning, operations, fault handling, and acceptance — meeting users’ multi-dimensional information needs
  • Content update mechanism: Regular updates to protocol signature libraries, fault handling solutions, and industry standards as products iterate

17.2.2 Title Tag

Network Traffic Analysis Device Installation Wiring Commissioning Manual_Full Capture Traffic Replay Analysis Device Operations Guide – Guangzhou Lain Intelligent System Development Co., Ltd.

17.2.3 Meta Keywords

Network Traffic Analysis Device, Full Capture Traffic Analysis Device, NTA Traffic Analysis, Network Traffic Monitoring, Traffic Replay Device, Network Performance Analysis, Traffic Analysis Device Installation, Traffic Analysis Device Commissioning, KITOZER Traffic Analysis Device

17.2.4 Meta Description

Guangzhou Lain Intelligent System Development Co., Ltd. professionally researches and develops network traffic analysis devices. This manual details the complete process including product principles, technical parameters, installation wiring, commissioning operations, fault handling, and project acceptance for traffic analysis devices. Supports full capture replay, deep protocol parsing, and security threat detection — suitable for data centers, enterprise data centers, telecom operators, government, education, and more.

17.2.5 H1 Tag

Network Traffic Analysis Device Installation, Wiring & Commissioning Manual

17.2.6 H2 Tags

Product Introduction, Product Composition, Product Classification, Product List, Product Principles, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Product Common Issues and Solutions, Product Q&A, Product Acceptance

17.2.7 Internal Link Optimization Tags (Anchor Text, Natural Integration)

  • Core anchor text: Network Traffic Analysis Device, Full Capture Traffic Analysis Device, Traffic Replay Analysis
  • Long-tail anchor text: Network Traffic Analysis Device Installation Method, Network Traffic Analysis Device Wiring Tutorial, Network Traffic Analysis Device Commissioning Steps, Out-of-Band Traffic Analysis Device Deployment Plan
  • Related anchor text: Data Center Environment Monitoring System, Micro-Module Cold Aisle, Shielded Data Center Construction, Precision Air Conditioning, UPS Uninterruptible Power Supply

Chapter 18 Copyright Statement and Reprint Guidelines

18.1 Copyright Statement

All content in this document is copyrighted by Guangzhou Lain Intelligent System Development Co., Ltd., protected by the Copyright Law of the People’s Republic of China and relevant international copyright conventions. Without written formal authorization from our company, no entity, organization, or individual may copy, reproduce, excerpt, modify, distribute, sell, or use any part or all of this document for any purpose or commercial use.

Product models, technical architectures, functional designs, appearance designs, and trademark identifiers mentioned in this document are exclusive intellectual property of our company. Imitation will be prosecuted. Our company reserves the right to pursue legal liability and economic compensation for all infringement acts.

18.2 Reprint and Reproduction Requirements

  • Non-commercial citation: For non-commercial purposes of technical exchange, study/research, or internal training, the source must be clearly attributed to “Guangzhou Lain Intelligent System Development Co., Ltd.” with the official website source link attached. Cited content must not distort or alter the original meaning, nor be taken out of context to mislead readers.
  • Commercial reprint: Any commercial reprint, reuse, or secondary distribution must submit a written application to our company in advance and may only be used after receiving formal authorization documentation. Usage must strictly comply with the authorized scope, method, and period — no distribution beyond authorized scope.
  • Content update notice: This document will be revised periodically as products and technologies evolve and standards update. All content is subject to the latest official version. Our company is not obligated to provide separate notification of version changes. Older versions are for historical reference only; our company assumes no responsibility for their accuracy or timeliness.
  • Disclaimer: This document serves only as technical guidance for product installation and use. Our company, within the limits permitted by law, assumes no responsibility for equipment damage or business losses caused by failure to operate according to specifications, unauthorized device modification, or non-compliant deployment. Specific product functions, parameters, and configurations are subject to the actual delivered equipment and formal contract agreement.

Contact Us

Manufacturer: Guangzhou Lain Intelligent System Development Co., Ltd.

Service Hotline: +86 13538869979 (also on WeChat)

Technical Support: +86 13538869979

Company Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou

Official Website: gdlain.com

Shopping Cart