KITOZER Nitrogen Oxide (NOx) Monitoring System Quotation List
Table of Contents

2. Project Requirement Description
To meet the nitrogen oxide (NOx) emission monitoring requirements at flue gas discharge outlets of industrial boilers, kilns, incinerators and similar combustion sources, the project requires the construction of a continuous online monitoring system that delivers:
- Real-time monitoring of NO, NO₂ and NOx concentrations, together with key flue gas parameters (temperature, pressure, flow velocity, humidity)
- Reliable data storage and automatic upload to environmental protection regulatory platforms
- Full compliance with flue gas emission supervision standards and environmental acceptance requirements
- Data support for plant denitrification (DeNOx) process optimization and emission reduction management
3. System Composition Introduction
The system is composed of five major units:
- Flue gas sampling unit
- Pretreatment unit
- Nitrogen oxide analysis unit
- Data acquisition and transmission unit
- Monitoring platform
Key components include: sampling probe, heat-traced sampling line, dust removal filter, dehumidifier, electrochemical detector, industrial control host, communication module and platform software.
4. Core Product Specifications & Parameters
| Parameter | Technical Specification |
|---|---|
| Product Model | KZR-NOx-01 |
| Detection Principle | Electrochemical detection method (customizable to non-dispersive infrared / NDIR method) |
| Monitoring Factors | NO, NO₂, NOx; expandable to O₂, SO₂, etc. |
| Measurement Range | NO: 0-1000 mg/m³; NO₂: 0-200 mg/m³; NOx: 0-1200 mg/m³ |
| Detection Accuracy | ≤±2% F.S |
| Resolution | 0.01 mg/m³ |
| Zero Drift | ≤±1% FS/7d |
| Span Drift | ≤±2% FS/7d |
| Response Time | ≤60 s |
| Working Environment | Temperature: -20°C to 50°C; Humidity: 0-95%RH |
| Protection Rating | IP54 (cabinet type) |
| Communication Protocol | HJ212-2017, Modbus-RTU |
| Data Storage | Local ≥12 months |
| Power Supply | AC220V±10%, 50Hz |
5. Core Functions & Features of Products
Core Functions:
- Continuous Monitoring: 24-hour uninterrupted collection of nitrogen oxide concentrations with synchronized monitoring of flue gas temperature, pressure, flow velocity and moisture content
- Data Statistics: Automatic calculation of hourly averages, daily averages and total emissions; generation of compliant regular reports
- Over-limit Alarm: Customizable concentration thresholds with three-tier warning via audible/visual alarm, SMS and platform notification
- Data Upload: Automatic connection to environmental supervision platforms with breakpoint-resume transmission for stable data delivery
- Process Linkage: Interfaces with denitrification control systems to automatically adjust reagent dosing based on real-time monitoring data
- Operation & Maintenance Management: Equipment self-diagnosis, fault alarm and remote calibration to reduce maintenance workload
Key Features:
- High-precision imported electrochemical sensors with good selectivity and strong anti-interference capability
- Dual-zone temperature control technology with independent temperature regulation for optical components and sampling lines to prevent data drift
- Multi-stage pretreatment system providing effective dust removal and dehumidification for high-dust, high-humidity flue gas conditions
- Intelligent temperature and pressure compensation algorithm that eliminates the influence of operating condition changes on measurement results
- Integrated cabinet-style design with high compactness for easy installation and maintenance
- Power-off protection and data backup ensuring data security and reliability
6. Core Advantages of The Solution
- Regulatory Compliance: Data accuracy and transmission meet national continuous flue gas emission monitoring standards and satisfy environmental acceptance requirements
- Strong Adaptability: Suitable for boilers, kilns, incinerators and other flue gas emission scenarios; resistant to high temperature and dust
- Low Operation & Maintenance Cost: Long sensor service life, extended calibration intervals and low consumable replacement costs
- Excellent Expandability: Additional monitoring factors such as SO₂, O₂ and particulate matter can be added flexibly without replacing the main unit
- Complete Service: Full-process support including on-site installation, commissioning, calibration and operator training
7. Manufacturer Strength Introduction
The product is independently researched, developed and manufactured by Guangzhou Lai’an Intelligent System Development Co., Ltd. and Guangdong Lai’an Smart Computer Room Equipment Co., Ltd., under the proprietary brand KITOZER.
- Founded in 2002, certified to ISO 9001, ISO 14001 and ISO 45001 management systems
- Recognized high-tech enterprise with a professional gas monitoring R&D team and standardized production workshops
- Capabilities include customized development, OEM processing, confidential cooperation and spot stock supply
- Every product undergoes strict calibration and aging tests before shipment, ensuring stable and reliable quality
- Project-confirmed manufacturing with rapid after-sales response available nationwide and internationally
8. Detailed Quotation Table
| No. | Product Name | Model & Spec | Technical Parameter | Qty | Unit | Unit Price (USD) | Total Price (USD) | Brand | Remark |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Nitrogen Oxide Monitoring Host | KZR-NOx-01 | Electrochemical detection, NO/NO₂/NOx three parameters, ±2% accuracy, 7-inch touch display | 1 | Unit | 18,647.33 | 18,647.33 | KITOZER | Includes core analysis module and main controller |
| 2 | Flue Gas Sampling & Pretreatment System | KZR-YCL-NO02 | Heated sampling probe, heat-traced sampling line, two-stage filter, dehumidifier, sampling pump | 1 | Set | 5,771.79 | 5,771.79 | KITOZER | Full-line heat tracing at 120°C |
| 3 | Data Acquisition & Transmission Unit | KZR-CS-04 | Industrial-grade control host, 4G/Ethernet communication, HJ212 protocol, including 1 year data traffic | 1 | Set | 2,663.90 | 2,663.90 | KITOZER | Compatible with environmental supervision platforms |
| 4 | Flue Gas Monitoring Management Platform | KZR-PT-NO1.0 | Data display, statistical analysis, report generation, over-limit warning, B/S architecture | 1 | Set | 3,995.86 | 3,995.86 | KITOZER | Permanent license, 1 year free maintenance |
| 5 | Installation Accessories & Materials | KZR-FC-06 | Sampling tube bracket, signal cables, power surge protector, wiring accessories, etc. | 1 | Set | 1,331.95 | 1,331.95 | KITOZER | Standard installation kit |
Total Quotation Price: USD 32,410.83
9. Quotation Terms & Conditions
- Currency & Basis: All prices are quoted in USD, based on EXW Guangzhou, China (or as otherwise negotiated)
- Tax: The above prices exclude tax and freight. VAT special invoice requires an additional 10% tax point; VAT ordinary invoice requires an additional 3% tax point
- Freight: Goods are shipped by logistics with freight collect (payable upon delivery)
- Payment Terms: 30% deposit with 70% balance before shipment (negotiable)
- Lead Time: 15-30 working days depending on system configuration
- Validity: This quotation is valid for 30 days from the date of issue
- Packing & Shipping: Packing and shipping costs are quoted separately upon request
10. After-sales Service Description
- Warranty: 12-24 months warranty depending on product type, with free repair or replacement for quality-related failures during the warranty period
- Technical Support: Lifetime remote technical support and consultation
- Spare Parts: Reliable availability of spare parts for all standard products
- On-site Service: Remote troubleshooting available as standard; on-site commissioning, calibration and repair services available upon request
- Training: Operator training provided at installation and on an ongoing basis as needed
11. Contact & Order Information
- Supplier: Guangzhou Lai’an Intelligent System Development Co., Ltd. (Brand: KITOZER)
- Order Channel: Orders can be placed via the official website (gdlain.com) or by contacting the KITOZER sales team directly
- Response Time: All inquiries receive a response within 24 hours
- Contact Person: Mr. Zhou, Sales Department (WeChat available at +86 13538869979)
- Address: Zhongrun Industrial Park, Chaotian Zone, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
12. SEO Keywords & Tags
KITOZER nitrogen oxide monitoring system quotation, NOx online monitoring system price list, boiler NOx continuous monitoring system quotation, flue gas nitrogen oxide analyzer factory price, NOx monitoring equipment wholesale price, industrial kiln NOx monitoring system cost, denitrification outlet NOx monitor price, electrochemical NOx analyzer project-confirmed, nitrogen oxide monitoring system manufacturer, KITOZER NOx monitoring instrument quotation, environmental monitoring NOx system price, gas analysis system supplier KITOZER