KITOZER
KITOZER

NOx Monitoring System CEMS for Emission Compliance

Product Overview

KITOZER nitrogen oxide (NOx) monitoring system is a high-precision online monitoring solution designed for fixed pollution source flue gas emissions. It continuously measures NO, NO₂, NOx concentrations, oxygen content, temperature, pressure, flow, and humidity in real time, suitable for boilers, kilns, incinerators, and other emission outlets. This system meets ultra-low emission regulatory requirements, providing data support for enterprise pollution control and environmental compliance.

Product Introduction

Product Positioning

Targeting fixed pollution source flue gas emissions, this NOx online monitoring system delivers continuous, real-time monitoring of NO, NO₂, NOx, oxygen content, temperature, pressure, flow, and humidity. It is applicable to emission monitoring of boilers, kilns, incinerators, and more, satisfying ultra-low emission supervision requirements and providing data support for enterprise pollution control and environmental compliance.

Core Value

The system solves the pain points of inaccurate nitrogen oxide emission monitoring, non-traceable data, and high environmental compliance risks. It enables continuous automatic flue gas emission monitoring with real-time data upload to environmental platforms, meeting regulatory requirements. It also helps enterprises optimize combustion processes and denitrification system operations, reducing denitrification reagent consumption and achieving dual benefits of energy saving and emission compliance.

Product Highlights

  • Multiple detection principles available: UV differential, electrochemical, zirconia – adaptable to different working conditions.
  • Multi-stage flue gas pretreatment system suitable for high dust, high humidity, and high temperature flue gas.
  • High data accuracy, low zero drift, stable long-term operation.
  • Supports HJ212 protocol for direct connection to environmental supervision platforms at all levels.
  • Automatic calibration and auto-back-purge functions for low maintenance.

Product Classification and Composition

Product Classification

By detection principle: UV differential absorption spectroscopy (DOAS) NOx monitoring system, electrochemical NOx monitoring system, zirconia in-situ NOx analyzer.

By application scenario: fixed pollution source CEMS system, fugitive emission NOx monitoring system at plant boundary.

System Composition

The system consists of sampling unit (sampling probe, heat-traced line), pretreatment unit (dust removal, dehydration, filtration components), gas analysis unit (NOx analyzer, oxygen analyzer), data acquisition and transmission unit, temperature/pressure/flow monitoring unit, and calibration unit, along with a cloud platform management system.

Core Advantages

Material Advantages

  • Sampling probe: 316L stainless steel, high temperature and corrosion resistant.
  • Heat-traced line: PTFE inner lining to prevent adsorption and corrosion.
  • Analyzer cavity: hard anodized aluminum alloy, good air tightness and anti-interference.
  • Cabinet: cold-rolled steel plate with electrostatic spraying, dustproof and anticorrosive.

Process Advantages

  • Full heat-traced sampling process at ≥120°C to prevent NOx condensation loss.
  • Multi-stage precision filtration removes dust and moisture from flue gas, protecting core analysis components.
  • Optical platform with constant temperature control minimizes environmental temperature impact on detection accuracy.
  • EMC electromagnetic compatibility tested to resist industrial field interference.

Customization Advantages

  • Customized pretreatment solutions for high dust, high humidity, and strongly corrosive flue gas.
  • Expandable to measure SO₂, CO, particulate matter, and other pollutants.
  • Support for different communication protocols and platform integrations.
  • Custom cabinet size and mounting method to fit various site spaces.

Cost Advantages

  • Integrated design reduces installation and commissioning costs.
  • Auto-purge and auto-calibration reduce manual maintenance.
  • Long core component life and long replacement cycles lower ongoing maintenance costs.
  • project-confirmed configuration offers high cost-performance.

Quality Advantages

  • Core analysis modules use imported sensors/optical components for high accuracy and stability.
  • System complies with national continuous emission monitoring standards and is CCEP certified.
  • 72-hour continuous operation test and calibration gas verification before shipment.
  • Data accuracy ≥95%, system effective data rate ≥90%.

Product Category Details

Electrochemical NOx Monitoring System

Uses imported electrochemical sensors, moderate cost, suitable for medium-to-low concentration and relatively simple boiler flue gas monitoring. Easy installation and maintenance.

Ultraviolet Differential (DOAS) NOx Monitoring System

Uses UV spectral absorption technology with high accuracy and strong anti-interference capability. Ideal for ultra-low emission requirements in power plants, steel mills, cement plants, and other heavy-polluting industries.

In-situ Zirconia NOx Analyzer

Directly mounted on the duct, no sampling line needed, fast response, suitable for high-temperature flue gas. Simple structure, low maintenance.

Explosion-proof NOx Monitoring System

Explosion-proof certified (Exd IIC T6), suitable for flammable and explosive environments such as petrochemical and chemical plants.

Materials & Process Analysis

Material Details

  • Sampling probe: 316L stainless steel with built-in 2μm sintered stainless steel filter, temperature resistance up to 600°C, corrosion resistant.
  • Heat-traced line: inner PFA PTFE tube, middle constant-power heating tape, outer insulating flame-retardant layer, uniform controllable temperature.
  • Analyzer cavity: hard anodized aluminum alloy, good air tightness, inert internal surface to reduce gas adsorption and ensure accuracy.
  • Cabinet: 1.5mm cold-rolled steel plate, electrostatic spraying, IP54 protection.

Core Process Description

  • Full heat-traced sampling: from probe to analyzer inlet, constant temperature 120-180°C, preventing NO₂ condensation and adsorption, ensuring sample authenticity.
  • Multi-stage pretreatment: cyclone dust removal + precision filtration + electronic condensation dehumidification, effectively removing dust and moisture, avoiding interference and protecting core components.
  • UV differential detection: uses characteristic absorption spectra of gas molecules, differential algorithm eliminates interference from dust and moisture, no consumables, long-term stability.

Safety Certifications

  • CCEP China Environmental Protection Product Certification.
  • Complies with HJ 76-2017 (Technical Requirements and Test Methods for Continuous Emission Monitoring Systems of Stationary Source Flue Gas).
  • ISO9001 Quality Management System Certification.
  • Explosion-proof model: Exd IIC T6 explosion-proof certification.
  • Data transmission complies with HJ 212-2017 standard.

Technical Specifications

Parameter Specification
———– —————
Measured components NO, NO₂, NOx, O₂ (expandable to SO₂, CO, CO₂, etc.)
Measurement range NOx: 0~100mg/m³ (customizable 0~500/1000mg/m³); O₂: 0~25%
Detection principle UV DOAS / Electrochemical / Zirconia
Zero drift ≤±2%FS/7d
Span drift ≤±2%FS/7d
Response time ≤90s
Sampling temperature -40℃~600℃ (standard), higher on request
Sampling humidity 0~99%RH
Communication RS485, 4G, Ethernet, supports HJ212 protocol
Operating temperature -10℃~50℃
Protection grade IP54

Detailed Parameter Table

No. Parameter Technical Index Remarks
—– ———– —————– ———
1 Monitoring components NO, NO₂, NOx, O₂ Expandable
2 Measurement range NOx: 0~100mg/m³ Customizable
3 Zero drift ≤±2%FS/7d
4 Span drift ≤±2%FS/7d
5 Response time ≤90s T90
6 Sampling temperature ≤600℃ High-temp version on request
7 Communication protocol HJ212-2017, Modbus
8 Operating temperature -10℃~50℃
9 Protection grade IP54
10 Data effective rate ≥90%

Product SKUs

  • Basic: Electrochemical NOx Monitoring System, SKU: KITOZER-NOx-001
  • Standard: UV Differential NOx Monitoring System, SKU: KITOZER-NOx-002
  • In-situ: Zirconia In-situ NOx Analyzer, SKU: KITOZER-NOx-003
  • Explosion-proof: Explosion-proof NOx Monitoring System, SKU: KITOZER-NOx-004

Stock Availability

  • Electrochemical and UV differential standard systems have core components in stock; standard configurations ship within 10 working days.
  • Calibration gas, filters, and other consumables are in stock and shipped with the equipment.
  • Standard systems are pre-commissioned at the factory; on-site wiring enables quick start-up.
  • Emergency projects can be prioritized for production to ensure delivery time.

OEM/ODM Services

We provide full OEM/ODM services for NOx monitoring systems, supporting brand labeling, appearance customization, and functional customization. Strict confidentiality agreements protect customer technical solutions, project information, and customer resources. Neutral packaging and manuals are available to support customer’s own brand promotion. Our mature production supply chain ensures quality and delivery for OEM products.

Customization Services

Customization Scope

  • Monitoring parameters: expand to SO₂, particulate matter, HCl, ammonia slip, etc.
  • Working condition adaptation: custom pretreatment for high temperature, high dust, high humidity, and strong corrosion.
  • System integration: connect to customer DCS, PLC, or local environmental platform.
  • Structure: custom cabinet size, mounting method, explosion-proof rating.

Customization Process

  1. Site survey: understand flue gas parameters, site conditions, and emission requirements.
  2. Solution design: provide custom solution and selection quotation within 3-5 working days.
  3. Contract confirmation: confirm technical solution, delivery period, sign contract.
  4. Production and testing: custom production, simulated working condition test in factory.
  5. On-site acceptance: installation, commissioning, and customer acceptance.

Customization Advantages

  • Experienced flue gas monitoring technical team familiar with various industry conditions for precise solutions.
  • Modular product design reduces customization cost and lead time.
  • Factory simulation testing ensures quick start-up on site.
  • Full-process technical support with same warranty and after-sales service.

Application Scenarios

  • Power industry: coal/gas-fired power plant boiler flue gas NOx emission monitoring.
  • Industrial boilers: steel, cement, glass, chemical industry kilns and boiler flue gas monitoring.
  • Incineration: waste-to-energy plants, hazardous waste incinerators.
  • Chemical industry: nitric acid plants, fertilizer plants process gas NOx monitoring.
  • Others: gas-fired boilers, biomass boilers, ceramic kilns, etc.

Success Cases

Representative Customers

  • A thermal power company, a steel group, a waste-to-energy plant.

Case Highlights

  • For a thermal power company: equipped 2 coal-fired boilers with UV DOAS NOx monitoring systems, achieving ultra-low emission monitoring. Data stably uploaded to provincial environmental platform, passed environmental acceptance for three consecutive years, data effective rate above 98%.
  • For a steel mill: installed NOx monitoring system on sintering machine flue gas. Adapted to high dust and high humidity conditions. Pretreatment ran stably, assisted in optimizing denitrification process, reduced denitrification reagent consumption by 10%, achieving stable compliance.
  • For a waste-to-energy plant: customized multi-component flue gas monitoring system with simultaneous NOx, SO₂, particulate monitoring. Corrosion-resistant system adapted to complex flue gas, stable operation for over 2 years.

Procurement Service Guarantee

Supply Guarantee

Self-developed and manufactured, core components well stocked, short lead times for standard products. Custom products have dedicated project tracking for on-time delivery.

Quality Guarantee

Strict production and testing per environmental standards, factory calibration and aging test. Full certification documents provided: CCEP certification, test reports, product certificates.

Logistics Guarantee

Anti-vibration, moisture-proof packaging with cushioning for precision parts. Professional logistics with door-to-door delivery ensuring safe transport.

After-sales Guarantee

  • 1-year warranty on complete system, 2-year warranty on core analyzer.
  • Free installation, commissioning, and operation training.
  • 7×24 technical support, fault response ≤2 hours, on-site response within 24 hours in the province.

Invoice Guarantee

13% VAT special invoice provided, sent with goods. Accurate invoicing information.

Call-to-Action

  • Get a Quote | Site Survey | Request a Sample | Technical Consultation
  • Phone: 13538869979 / 13538869979
  • Address: No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China (Chao Tian Industrial Park)
  • Promotion: Free on-site survey and solution for new projects, discounts for bulk orders, annual maintenance package discounts.

FAQ

Q: Can the system connect to local environmental platform?

A: Yes, the system supports HJ212-2017 standard communication protocol and has been adapted to environmental platforms in many provinces. Data upload and acceptance are ensured.

Q: Does high-dust flue gas affect operation?

A: The system includes multi-stage dust filtration and auto-purge function, suitable for high-dust conditions. Regular filter replacement ensures stable operation.

Q: How often calibration is needed?

A: The system supports auto-calibration. We recommend manual calibration gas verification every 3 months, adjustable based on site conditions.

Product Faults and Maintenance

Common Faults and Solutions

  • Low or no data: check sampling line for blockage, sampling pump operation, clean filter, check analyzer status.
  • Fluctuating data: check pretreatment dehumidification, line leakage, perform zero calibration.
  • Data not uploading: check communication module, network connection, confirm platform parameters.

Maintenance Schedule

  • Weekly: check sampling pump, heat-traced system, filter contamination.
  • Monthly: clean dust, check line airtightness, clean filter elements.
  • Quarterly: perform zero and span calibration, check pretreatment component wear.
  • Annually: full system maintenance, replace wear parts, verify performance.

Factory Strength and After-sales Service

Factory Strength

  • Professional R&D and production base for flue gas monitoring equipment with optical laboratory and gas calibration laboratory.
  • Years of CEMS development and production experience, multiple environmental certifications.
  • Core technical team with extensive industrial flue gas monitoring project experience.
  • Full-chain service from selection, production, installation to operation and maintenance.

After-sales Service

  • Comprehensive environmental equipment operation and maintenance service system, providing daily maintenance, fault repair, and periodic calibration.
  • Dedicated account manager for one-on-one follow-up, rapid response.
  • Free repair or replacement of non-artificial damaged parts during warranty period.
  • Annual maintenance service packages to ensure long-term stable operation.

Conclusion

The nitrogen oxide online monitoring system is core equipment for enterprises to fulfill environmental responsibilities and achieve emission compliance. We remain driven by technological innovation, providing stable, reliable, and accurate flue gas monitoring solutions to help enterprises achieve green production and sustainable development.

Scroll to Top