Table of Contents
Toggle1. System Overview
The outdoor ETC cabinet (also known as the ETC outdoor integrated intelligent cabinet) is the core supporting facility of the expressway ETC gantry system. Specially designed for extreme outdoor environments, it integrates power supply & distribution, constant temperature heat dissipation, lightning protection & grounding, intelligent monitoring, anti-theft protection and other functions into one unit. It provides a safe, stable and reliable operating environment for key equipment such as RSU transaction controllers, lane controllers, industrial switches and industrial personal computers, ensuring 7×24-hour uninterrupted operation of the ETC system. It is an important infrastructure for the construction of smart expressway networks.
Adopting a modular and integrated design, the system features high protection grade, high reliability, easy deployment and convenient maintenance. It can adapt to complex outdoor scenarios with high temperature, severe cold, heavy rain, salt spray, sand and dust, effectively solving pain points of traditional equipment deployed in open air including easy damage, high operation and maintenance costs and poor safety. It is widely applied to ETC toll collection scenarios such as expressway mainline gantries, toll stations and urban express roads.
2. System Composition
The outdoor ETC cabinet system consists of seven core modular units: cabinet structure unit, power supply & distribution unit, constant temperature heat dissipation unit, lightning protection & grounding unit, intelligent monitoring unit, fire protection & security unit, and network communication unit. All units work collaboratively to form a complete guarantee system for outdoor equipment operation.
2.1 Cabinet Structure Unit
As the carrier of the whole system, it adopts a double-layer sheet metal structure with high strength, corrosion resistance and anti-aging performance. It is equipped with a built-in 19-inch standard rack, cable management system, sealed waterproof components and anti-theft door locks, providing installation space and physical protection for all functional units.
2.2 Power Supply & Distribution Unit
It includes mains input module, UPS uninterruptible power supply, backup battery pack, intelligent PDU, dual power automatic transfer switch and optional photovoltaic auxiliary power supply module. It realizes mains voltage stabilization, power-off endurance, intelligent power distribution and redundant power backup to guarantee non-interrupted power supply for equipment.
2.3 Constant Temperature Heat Dissipation Unit
Composed of industrial air conditioner, emergency cooling fan, electric heater, thermal insulation layer and anti-condensation device, it supports automatic dual-mode cooling and heating to precisely control the temperature and humidity inside the cabinet. It can withstand extreme ambient temperatures ranging from -40℃ to +80℃, preventing equipment breakdown caused by overheating, low-temperature faults or short circuits induced by condensation.
2.4 Lightning Protection & Grounding Unit
It comprises power surge protectors, signal surge protectors, grounding busbars and lightning protection cables. Adopting a three-level lightning protection design, it effectively resists direct lightning strikes, induced lightning and surge impacts to protect internal equipment from lightning damage, with grounding resistance ≤4Ω.
2.5 Intelligent Monitoring Unit
Centered on an environment monitoring host, it is matched with temperature & humidity sensors, water immersion sensors, smoke sensors, door contact sensors, voltage & current sensors, etc. It collects real-time data of internal cabinet environment and equipment operating status, supporting local display, remote transmission, abnormal alarms, data storage and analysis.
2.6 Fire Protection & Security Unit
It contains heptafluoropropane fire extinguishers, audible & visual alarms, electronic anti-theft locks and optional door-opening capture cameras. It delivers full-range safety protection for cabinets and equipment via fire early warning, automatic fire suppression, illegal door opening alarms and video monitoring.
2.7 Network Communication Unit
Made up of industrial switches, optical fiber transceivers, 4G/5G transmission modules and network security devices, it provides a stable transmission channel for ETC service data and monitoring data, supporting data encryption and remote operation & maintenance access to ensure safe and reliable communication.
3. System Classification
Outdoor ETC cabinets are classified by four dimensions: structural form, installation scenario, protection grade and functional configuration, meeting demands of diverse application scenarios and budget limits.
3.1 Classification by Structural Form
- Single-compartment ETC Cabinet: Integrated single cabin design with all functional units built-in, compact structure and small floor area. Suitable for space-limited scenarios such as small toll stations and branch road gantries.
- Dual-compartment ETC Cabinet: Separated into equipment compartment and power compartment. Business equipment is installed in the equipment compartment while UPS and storage batteries are placed in the power compartment. Partition isolation optimizes heat dissipation and safety, making it the mainstream choice for expressway mainline gantries.
- Triple-compartment ETC Cabinet: Divided into equipment compartment, power compartment and monitoring compartment with more refined functional zoning for convenient maintenance. Applied to high-end scenarios including major transport hubs and provincial trunk lines.
3.2 Classification by Installation Scenario
- Gantry-mounted ETC Cabinet: Compact and lightweight, directly hoisted on the beam of ETC gantries to satisfy centralized equipment deployment on gantries, with IP65 protection grade.
- Roadside Floor-mounted ETC Cabinet: Standard size, installed on the ground beside expressway roadsides or toll stations. Featuring strong load-bearing capacity and good heat dissipation, it facilitates maintenance and enjoys the widest application.
- Toll Station Embedded ETC Cabinet: Adapted to toll island structures of toll stations with embedded installation, integrated aesthetic design matching toll booths, IP55 protection grade.
3.3 Classification by Protection Grade
- Basic Protection Type (IP55): Dustproof and splash-proof, applicable to inland dry and low-rainfall regions to meet general outdoor protection requirements.
- High Protection Type (IP65): Dustproof and rainproof with fully sealed structure, suitable for rainy, humid and coastal salt spray areas with excellent anti-corrosion and anti-aging performance.
- Military-grade Protection Type (IP67): Dustproof and immersion-proof with high-strength sealing, applied to extremely harsh environments such as plateaus, deserts and typhoon-prone regions.
3.4 Classification by Functional Configuration
- Basic ETC Cabinet: Standard equipped with cabinet body, basic power distribution, simple heat dissipation and elementary monitoring. It meets the basic operation demands of core ETC equipment with low budget, suitable for small-scale projects.
- Standard ETC Cabinet: Upgraded from basic type with UPS endurance, industrial air conditioner, comprehensive environment monitoring and lightning protection & grounding. It boasts complete functions and high cost performance, widely adopted in expressway projects.
- Intelligent High-end ETC Cabinet: Integrated with photovoltaic power supply, 5G transmission, AI intelligent analysis, remote intelligent control and video security linkage, supporting unattended intelligent operation & maintenance for smart expressway demonstration projects.
4. System Schematic Diagrams
4.1 Overall System Architecture Schematic
4.2 Power Supply & Distribution System Schematic
Mains Input → Three-level Lightning Protection → Dual Power Transfer Switch → UPS → PDU → All Electrical Equipment; Storage battery packs are connected in parallel with UPS to realize seamless power switching during mains power failure and guarantee endurance.
4.3 Constant Temperature Heat Dissipation System Schematic
Internal cabinet temperature sensor → Environment Monitoring Host → Air Conditioner / Cooling Fan / Electric Heater: The air conditioner activates cooling when temperature exceeds 35℃; the heater turns on when temperature drops below 5℃; auxiliary fans work for heat dissipation under normal temperature; the anti-condensation device starts when humidity exceeds 80% RH.
4.4 Intelligent Monitoring System Schematic
Various sensors (temperature & humidity, water immersion, smoke, door contact) → Environment Monitoring Host → Local Display Screen / Audible & Visual Alarm; Environment Monitoring Host → Industrial Switch → 4G/5G / Optical Fiber → Cloud Operation & Maintenance Platform → Remote Monitoring Terminals (PC / Mobile APP).
5. Complete System Configuration List (KITOZER Brand)
5.1 Basic Low-end Configuration List
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Outdoor ETC Cabinet (Single-compartment) | KITOZER-ETC-D1800 | Size:1800×700×500mm; 1.5mm galvanized steel plate; IP55; 20mm thermal insulation layer; 19-inch rack; front & rear double doors; mechanical anti-theft lock | 1 | Set | KITOZER | Basic cabinet, for inland regions |
| 2 | Intelligent PDU | KITOZER-PDU-8C | 8 standard national sockets; AC220V input; Max. 10A current; lightning protection; overload protection | 1 | Piece | KITOZER | Basic power distribution |
| 3 | UPS Uninterruptible Power Supply | KITOZER-UPS-1K | Capacity:1KVA/800W; Online double-conversion; Input AC220V±10%; Output AC220V±2%; Endurance ≥30min | 1 | Set | KITOZER | Short-duration power-off backup |
| 4 | Lead-acid Storage Battery | KITOZER-BAT-12V24AH | 12V/24AH; Valve-regulated sealed type; Float charging voltage 13.5-13.8V; Cycle charging voltage 14.4-14.8V | 2 | Piece | KITOZER | Matched with UPS |
| 5 | Axial Cooling Fan | KITOZER-FAN-12038 | Size 120×120×38mm; AC220V; Power 25W; Air volume 120m³/h; Low-noise design | 2 | Piece | KITOZER | Basic heat dissipation |
| 6 | Temperature & Humidity Sensor | KITOZER-SENSOR-TH | Temp range: -20℃~+60℃; Humidity range:0~100%RH; Accuracy ±0.5℃, ±3%RH; RS485 output | 1 | Piece | KITOZER | Environmental monitoring |
| 7 | Door Contact Sensor | KITOZER-SENSOR-DM | Normally open type; Response time ≤1s; DC12V operating voltage; Waterproof design | 1 | Piece | KITOZER | Cabinet door opening/closing monitoring |
| 8 | Primary Power Surge Protector | KITOZER-SPD-220V-1 | Nominal discharge current 60KA; Max discharge current 120KA; Voltage protection level ≤1000V; AC220V | 1 | Set | KITOZER | Power lightning protection |
| 9 | 5-port Industrial Switch | KITOZER-SW-5P | 5-port 100M; POE power supply supported; DC12V power supply; Metal housing; IP30 | 1 | Set | KITOZER | Data transmission |
| 10 | Basic Environment Monitoring Host | KITOZER-DH-BASIC | Supports 4 sensor access channels; RS485/Ethernet; Local LED display; Optional SMS alarm; DC12V power supply | 1 | Set | KITOZER | Basic monitoring management |
5.2 Standard Mid-range Configuration List
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Outdoor ETC Cabinet (Dual-compartment) | KITOZER-ETC-S2000 | Size:2000×800×600mm; 2.0mm galvanized steel with electrostatic spraying; IP65; 25mm flame-retardant thermal insulation layer; 19-inch rack; front & rear double doors; electronic anti-theft lock; waterproof sealing strip | 1 | Set | KITOZER | Mainstream cabinet, rainproof & moisture-proof |
| 2 | Intelligent PDU | KITOZER-PDU-12C | 12 standard national sockets; AC220V input; Max. 16A current; Three-level lightning protection; Overload/short circuit protection; Remote monitoring | 1 | Piece | KITOZER | Intelligent power distribution |
| 3 | UPS Uninterruptible Power Supply | KITOZER-UPS-3K | Capacity:3KVA/2400W; Online double-conversion; Input AC220V±15%; Output AC220V±1%; Endurance ≥60min; Intelligent voltage stabilization | 1 | Set | KITOZER | Standard power-off backup |
| 4 | Lead-acid Storage Battery | KITOZER-BAT-12V65AH | 12V/65AH; Valve-regulated sealed type; Float charging voltage 13.5-13.8V; Cycle charging voltage 14.4-14.8V; Service life ≥5 years | 4 | Piece | KITOZER | Matched with UPS |
| 5 | Industrial Cabinet Air Conditioner | KITOZER-AC-800W | Cooling capacity 800W; AC220V; Power 350W; Temp control range 0℃~+40℃; Dehumidification function; Low-noise design; IP55 | 1 | Set | KITOZER | Constant temperature heat dissipation |
| 6 | Electric Heater | KITOZER-HEAT-200W | Power 200W; DC24V; Temp control range -20℃~+10℃; Anti-condensation; Overheat protection | 1 | Set | KITOZER | Low-temperature heating |
| 7 | Premium Temperature & Humidity Sensor | KITOZER-SENSOR-TH-PRO | Temp range: -40℃~+80℃; Humidity range:0~100%RH; Accuracy ±0.3℃, ±2%RH; RS485/Ethernet; Waterproof & dustproof | 2 | Piece | KITOZER | High-precision environmental monitoring |
| 8 | Water Immersion Sensor | KITOZER-SENSOR-SJ | 5m sensing cable; DC12V operating voltage; Response time ≤2s; Detection precision ≤1mm; Waterproof design | 1 | Set | KITOZER | Water leakage monitoring |
| 9 | Smoke Sensor | KITOZER-SENSOR-YW | Photoelectric type; DC12V operating voltage; Response time ≤3s; Adjustable sensitivity; Waterproof & dustproof | 1 | Piece | KITOZER | Fire early warning |
| 10 | Premium Door Contact Sensor | KITOZER-SENSOR-DM-PRO | Normally open/closed switchable; Response time ≤0.5s; DC12-24V power supply; Waterproof & shockproof; Service life ≥100,000 times | 1 | Piece | KITOZER | Cabinet door monitoring |
| 11 | Three-level Power Surge Protector | KITOZER-SPD-220V-3 | Primary 60KA, Secondary 40KA, Tertiary 20KA; Voltage protection level ≤600V; AC220V; Modular design | 1 | Set | KITOZER | Full-range power lightning protection |
| 12 | Signal Surge Protector | KITOZER-SPD-SIGNAL | RS485/Ethernet signal lightning protection; Nominal discharge current 20KA; Voltage protection level ≤200V; Waterproof design | 2 | Piece | KITOZER | Signal lightning protection |
| 13 | 8-port Industrial Switch | KITOZER-SW-8P | 8-port 100M; 4-port POE power supply supported; DC12-24V power supply; Metal housing; IP40; Lightning protection design | 1 | Set | KITOZER | Data transmission |
| 14 | Standard Environment Monitoring Host | KITOZER-DH-STD | Supports 8 sensor access channels; RS485/Ethernet/4G; Local LCD display; SMS/APP alarm; Data storage ≥1 year; DC24V power supply | 1 | Set | KITOZER | Standard monitoring management |
| 15 | Audible & Visual Alarm | KITOZER-ALARM-SG | DC24V operating voltage; Volume ≥110dB; Red warning light; Waterproof design; Response time ≤1s | 1 | Set | KITOZER | Abnormal alarm notification |
5.3 Intelligent High-end Configuration List
表格
| No. | Product Name | Model & Specification | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Outdoor ETC Cabinet (Triple-compartment) | KITOZER-ETC-T2200 | Size:2200×900×700mm; 2.5mm 304 stainless steel; IP67; 30mm flame-retardant thermal insulation layer; 19-inch rack; front & rear double doors; intelligent electronic lock (Fingerprint/Remote/IC Card); double-layer waterproof seal; Anti-seismic design | 1 | Set | KITOZER | High-end cabinet, for coastal/extreme environments |
| 2 | Smart Intelligent PDU | KITOZER-PDU-16C-SMART | 16 standard national sockets; AC220V input; Max. 20A current; Four-level lightning protection; Overload/short circuit/leakage protection; Remote control & monitoring; Energy metering function | 1 | Piece | KITOZER | Intelligent remote power distribution |
| 3 | UPS Uninterruptible Power Supply | KITOZER-UPS-6K | Capacity:6KVA/4800W; Online double-conversion; Input AC220V±20%; Output AC220V±0.5%; Endurance ≥120min; Intelligent parallel redundancy; High precision voltage stabilization | 1 | Set | KITOZER | Long-duration power-off backup |
| 4 | Lead-acid Storage Battery | KITOZER-BAT-12V100AH | 12V/100AH; Valve-regulated sealed type; Float charging voltage 13.5-13.8V; Cycle charging voltage 14.4-14.8V; Service life ≥8 years; High temperature resistant design | 8 | Piece | KITOZER | Matched with UPS |
| 5 | Variable-frequency Industrial Cabinet Air Conditioner | KITOZER-AC-1200W | Cooling capacity 1200W; AC220V; Power 450W; Temp control range -20℃~+50℃; Dehumidification & heating dual mode; Variable frequency energy saving; Noise ≤45dB; IP65 | 1 | Set | KITOZER | Intelligent constant temperature heat dissipation |
| 6 | Smart Electric Heater | KITOZER-HEAT-500W | Power 500W; DC24V; Temp control range -30℃~+15℃; Anti-condensation; Overheat/overcurrent protection; Intelligent temperature linkage control | 1 | Set | KITOZER | Low-temperature intelligent heating |
| 7 | Ultra-high Precision Temperature & Humidity Sensor | KITOZER-SENSOR-TH-HD | Temp range: -50℃~+85℃; Humidity range:0~100%RH; Accuracy ±0.1℃, ±1%RH; RS485/Ethernet/Wireless; Waterproof, dustproof & anti-corrosion | 3 | Piece | KITOZER | Multi-point high-precision monitoring |
| 8 | Positioning Water Immersion Sensor | KITOZER-SENSOR-SJ-PRO | 10m sensing cable; DC24V operating voltage; Response time ≤1s; Positioning precision ≤0.5m; Waterproof & anti-corrosion design | 1 | Set | KITOZER | Precise water leakage location monitoring |
| 9 | Composite Smoke Sensor | KITOZER-SENSOR-YW-PRO | Photoelectric + ion composite type; DC24V operating voltage; Response time ≤2s; Adjustable sensitivity; Waterproof & dustproof; Service life ≥10 years | 1 | Piece | KITOZER | Accurate fire early warning |
| 10 | Smart Door Contact Sensor | KITOZER-SENSOR-DH-SMART | Programmable normally open/closed; Response time ≤0.3s; DC12-24V power supply; Waterproof & shockproof; Real-time status upload; Service life ≥200,000 times | 1 | Piece | KITOZER | Intelligent cabinet door monitoring |
| 11 | Four-level Power Surge Protector | KITOZER-SPD-220V-4 | Primary 80KA, Secondary 60KA, Tertiary 40KA, Quaternary 20KA; Voltage protection level ≤400V; AC220V; Intelligent monitoring & alarm | 1 | Set | KITOZER | Ultimate power lightning protection |
| 12 | Full-port Signal Surge Protector | KITOZER-SPD-SIGNAL-PRO | RS485/Ethernet/Fiber signal lightning protection; Nominal discharge current 30KA; Voltage protection level ≤150V; Waterproof & anti-corrosion; Intelligent alarm | 3 | Piece | KITOZER | Full-port signal lightning protection |
| 13 | 16-port Industrial Switch | KITOZER-SW-16P | 16-port Gigabit; 8-port POE power supply supported; DC12-48V power supply; Metal housing; IP50; Lightning/static protection; Redundant backup | 1 | Set | KITOZER | High-speed stable data transmission |
| 14 | Smart Environment Monitoring Host | KITOZER-DH-SMART | Supports 16 sensor access channels; RS485/Ethernet/4G/5G; Local touch LCD display; SMS/APP/phone alarm; Data storage ≥3 years; AI intelligent analysis; DC24V power supply | 1 | Set | KITOZER | Intelligent monitoring management |
| 15 | Smart Audible & Visual Alarm | KITOZER-ALARM-SG-PRO | DC24V operating voltage; Volume ≥120dB; Red & blue dual-color warning lights; Waterproof & anti-corrosion; Intelligent linkage; Remote control | 1 | Set | KITOZER | Intelligent alarm notification |
| 16 | HD Monitoring Camera | KITOZER-CAM-1080P | 1080P HD; Infrared night vision; Waterproof & dustproof; IP66; Motion detection; Door-opening snapshot; DC12V power supply | 1 | Set | KITOZER | Security monitoring & snapshot capture |
| 17 | Photovoltaic Power Supply Module | KITOZER-PV-200W | 200W monocrystalline silicon solar panel; MPPT controller; DC24V output; Lightning protection; Intelligent charging; Waterproof design | 1 | Set | KITOZER | Solar auxiliary power supply |
6. Complete Product Technical Parameters
6.1 Outdoor ETC Cabinet (KITOZER Series)
- Size Specifications
- Basic: 1800×700×500mm (Single-compartment)
- Standard: 2000×800×600mm (Dual-compartment)
- High-end: 2200×900×700mm (Triple-compartment)
- Material
- Basic: 1.5mm cold-rolled galvanized steel plate with electrostatic spraying surface
- Standard: 2.0mm cold-rolled galvanized steel plate with anti-corrosion electrostatic spraying surface
- High-end: 2.5mm 304 stainless steel plate with wire drawing surface treatment (corrosion-resistant & anti-aging)
- Protection Grade: Basic IP55, Standard IP65, High-end IP67
- Thermal Insulation Layer: Basic 20mm, Standard 25mm, High-end 30mm, all made of PEF flame-retardant tin foil thermal insulation cotton
- Rack Specification: 19-inch standard rack, 42U height, equipped with adjustable upper & lower support brackets
- Door Lock Type: Basic mechanical anti-theft lock, Standard electronic password lock, High-end intelligent electronic lock (fingerprint/remote/IC card three-in-one)
- Operating Environment: Temperature -40℃~+80℃, Humidity 0~100%RH (no condensation)
- Service Life: ≥15 years (under normal environment)
6.2 UPS Uninterruptible Power Supply (KITOZER Series)
- Rated Capacity: Basic 1KVA/800W, Standard 3KVA/2400W, High-end 6KVA/4800W
- Operation Mode: Online double-conversion
- Input Voltage: AC220V±10% (Basic), AC220V±15% (Standard), AC220V±20% (High-end)
- Output Voltage: AC220V±2% (Basic), AC220V±1% (Standard), AC220V±0.5% (High-end)
- Frequency: 50Hz±0.5Hz
- Battery Voltage: DC24V (Basic), DC48V (Standard), DC96V (High-end)
- Endurance Time: ≥30min (Basic), ≥60min (Standard), ≥120min (High-end)
- Protection Functions: Overload, short circuit, overvoltage, undervoltage, over-temperature, low battery protection
- Operating Environment: Temperature 0℃~+40℃, Humidity 20%~80%RH (no condensation)
6.3 Industrial Cabinet Air Conditioner (KITOZER Series)
- Cooling Capacity: No air conditioner for Basic type; Standard 800W; High-end 1200W variable frequency
- Rated Voltage: AC220V±10%
- Rated Power: Standard 350W; High-end 450W (variable frequency energy saving)
- Temperature Control Range: Standard 0℃~+40℃; High-end -20℃~+50℃
- Dehumidification Capacity: ≥0.5kg/h (Standard); ≥1.0kg/h (High-end)
- Noise Level: ≤50dB (Standard); ≤45dB (High-end)
- Protection Grade: IP55 (Standard); IP65 (High-end)
- Operating Environment: Temperature -20℃~+55℃, Humidity 0~100%RH (no condensation)
6.4 Environment Monitoring Host (KITOZER Series)
- Model: BASIC (Basic Version), STD (Standard Version), SMART (Intelligent Version)
- Supported Sensor Channels: ≥4 channels (Basic), ≥8 channels (Standard), ≥16 channels (Intelligent)
- Communication Interfaces: RS485/Ethernet (Basic); RS485/Ethernet/4G (Standard); RS485/Ethernet/4G/5G (Intelligent)
- Display Interface: LED digital tube (Basic); LCD liquid crystal screen (Standard); Touch LCD screen (Intelligent)
- Alarm Modes: Local audible & visual alarm (Basic); SMS/APP alarm (Standard); SMS/APP/phone/intelligent linkage alarm (Intelligent)
- Data Storage Duration: ≥3 months (Basic); ≥1 year (Standard); ≥3 years (Intelligent)
- Power Supply Voltage: DC12V (Basic); DC24V (Standard & Intelligent)
- Operating Environment: Temperature -20℃~+60℃, Humidity 10%~90%RH (no condensation)
6.5 Temperature & Humidity Sensor (KITOZER Series)
- Temperature Measuring Range: -20℃~+60℃ (Basic); -40℃~+80℃ (Standard); -50℃~+85℃ (Ultra-high Precision)
- Humidity Measuring Range: 0~100%RH (Full series)
- Measuring Accuracy
- Basic: ±0.5℃, ±3%RH
- Standard: ±0.3℃, ±2%RH
- Ultra-high Precision: ±0.1℃, ±1%RH
- Output Signal: RS485 (Basic/Standard); RS485/Ethernet/Wireless (Ultra-high Precision)
- Power Supply Voltage: DC12-24V
- Protection Grade: ≥IP55 (Basic); ≥IP65 (Standard); ≥IP67 (Ultra-high Precision)
6.6 Surge Protector (KITOZER Series)
- Power Surge Protector
- Basic: Single-level, 60KA, protection level ≤1000V
- Standard: Three-level, 60KA/40KA/20KA, protection level ≤600V
- High-end: Four-level, 80KA/60KA/40KA/20KA, protection level ≤400V
- Signal Surge Protector
- Standard: RS485/Ethernet, 20KA, protection level ≤200V
- High-end: Full-port, 30KA, protection level ≤150V
- Response Time: ≤25ns
- Operating Voltage: AC220V (Power type); DC12-24V (Signal type)
- Protection Grade: IP65
7. Product Application Scope
7.1 Outdoor ETC Cabinet
- Core Applications: Expressway ETC gantry systems, toll station ETC lanes, urban express road ETC toll collection points
- Extended Applications: Smart traffic monitoring, outdoor communication base stations, industrial field control, security monitoring equipment boxes, photovoltaic energy storage cabins
- Scenario Matching
- Inland regions: Basic IP55 cabinet
- Rainy & humid regions: Standard IP65 cabinet
- Coastal salt spray/plateau/desert regions: High-end IP67 stainless steel cabinet
7.2 UPS Uninterruptible Power Supply
- Core Applications: Core equipment inside ETC cabinets (RSU, lane controller, switch), servers, monitoring equipment, communication equipment
- Extended Applications: Industrial automation equipment, medical devices, precision instruments, emergency lighting systems, small computer rooms
- Scenario Matching
- Short power-off backup demand: 1KVA Basic model
- Standard endurance demand: 3KVA Standard model
- Long endurance & critical equipment demand: 6KVA High-end model
7.3 Industrial Cabinet Air Conditioner
- Core Applications: ETC cabinets, outdoor intelligent cabinets, industrial control cabinets, communication cabinets, outdoor equipment cabins
- Extended Applications: Outdoor power distribution boxes, photovoltaic inverter cabins, security monitoring boxes, mini outdoor computer rooms
- Scenario Matching
- Mild climate regions: Cooling fan only
- Conventional high-temperature regions: 800W Standard air conditioner
- Extreme high/low temperature regions: 1200W variable frequency air conditioner
7.4 Environment Monitoring System
- Core Applications: ETC cabinet environment & equipment monitoring, outdoor computer room monitoring, communication base station monitoring, industrial field monitoring
- Extended Applications: Smart building monitoring, security monitoring, energy management, environmental monitoring, unattended stations
- Scenario Matching
- Small stations: Basic monitoring version
- Standard projects: Standard monitoring version
- Intelligent operation & maintenance projects: Intelligent monitoring version
7.5 Sensors (Temperature & Humidity, Water Immersion, Smoke, Door Contact)
- Temperature & Humidity Sensor: ETC cabinets, computer rooms, warehouses, industrial workshops, outdoor environmental monitoring
- Water Immersion Sensor: ETC cabinets, computer rooms, basements, power distribution rooms, data centers
- Smoke Sensor: ETC cabinets, computer rooms, power distribution rooms, warehouses, industrial plants
- Door Contact Sensor: ETC cabinets, outdoor equipment boxes, computer rooms, security doors, industrial cabinet doors
8. Product Advantages
8.1 Overall Advantages of Full Series Products
- Strong Customization Capability: Customizable size, material, protection grade and functional configuration to fit diverse scenarios and budget limits.
- OEM & ODM Service: Support OEM/ODM processing and private labeling for customers’ brand operation.
- Strict Confidentiality Mechanism: Sign non-disclosure agreements to protect customers’ technical solutions, drawings, parameters and core information against leakage.
- Spot Inventory Supply: Core models stocked in large quantities for fast order response and shortened delivery cycle for urgent projects.
- Complete Product Line: Full range covering basic low-end to intelligent high-end models to realize one-stop procurement and reduce purchasing costs.
- High Reliability: Industrial-grade design passing strict high-low temperature, vibration and aging tests, adapting to extreme outdoor environments with low failure rate.
- Easy Deployment & Maintenance: Modular design pre-assembled in factory for fast on-site installation; standardized interfaces for convenient maintenance and lower operation & maintenance costs.
8.2 Advantages of Outdoor ETC Cabinet
- High Protection & Anti-corrosion: IP55/IP65/IP67 protection grade with double-layer sealing for waterproof and dustproof performance; galvanized steel / 304 stainless steel material with multi-layer anti-corrosion treatment, usable for over 15 years in coastal salt spray environments.
- High Strength & Anti-aging: Thickened plates with reinforcing ribs for wind and seismic resistance; high-quality sealing strips and locks resistant to temperature aging without long-term deformation.
- High Space Utilization: 19-inch standard rack with rational layout, reserving sufficient space for equipment installation and cable management.
- Multi-layer Anti-theft Protection: Mechanical lock / electronic lock / intelligent lock triple anti-pry design to prevent unauthorized door opening and protect internal equipment safety.
8.3 Advantages of UPS Uninterruptible Power Supply
- Pure Output Waveform with Online Design: Online double-conversion design outputs pure sine wave with high voltage stabilization precision to safeguard precision equipment.
- Wide Input Voltage Range: Adaptable to outdoor scenarios with severe grid voltage fluctuation, featuring wide input voltage tolerance and strong environmental adaptability.
- Intelligent Battery Management: Automatic charging, overcharge & overdischarge protection to extend battery service life; support battery temperature compensation.
- Energy-saving High Efficiency: High-frequency design for high-end models with efficiency ≥95% to cut power consumption and realize green environmental protection.
8.4 Advantages of Industrial Cabinet Air Conditioner
- Precise Temperature Control: Dual cooling & heating modes to accurately regulate internal cabinet temperature and humidity, eliminating equipment overheating shutdown and low-temperature malfunctions.
- Energy-saving & Low Noise: Variable frequency design for high-end models with low power consumption; silent fan with noise ≤45dB without interfering with equipment operation.
- Anti-condensation Design: Built-in dehumidification function to avoid short circuits caused by internal condensation in humid environments.
- Durable with High Protection: IP55/IP65 protection grade for waterproof and dustproof performance; industrial compressor with long service life and low failure rate.
8.5 Advantages of Environment Monitoring System
- Comprehensive Monitoring: Real-time collection of temperature & humidity, water immersion, smoke, door contact, voltage, current and other data to fully grasp cabinet operating status.
- Remote Intelligent Operation & Maintenance: 4G/5G / optical fiber transmission for remote monitoring, alarm and control via mobile APP or PC, realizing unattended operation and cutting maintenance costs.
- Traceable & Analyzable Data: Long-term data storage supporting historical data query, analysis and fault tracing to optimize operation & maintenance strategies.
- Strong Compatibility: Support TCP/UDP/SNMP protocols for docking with mainstream cloud platforms and monitoring systems with good scalability.
9. Bid-winning Controllable Technical Parameters (* marked mandatory parameters)
9.1 Outdoor ETC Cabinet
- Optional cabinet sizes: 1800×700×500mm, 2000×800×600mm, 2200×900×700mm
- Cabinet material thickness: Basic ≥1.5mm galvanized steel plate; Standard ≥2.0mm galvanized steel plate; High-end ≥2.5mm 304 stainless steel plate
- Protection grade: Basic type IP55, Standard type IP65, Intelligent type IP67
- Thermal insulation layer thickness: ≥20mm (Basic), ≥25mm (Standard), ≥30mm (High-end), all made of PEF flame-retardant tin foil thermal insulation cotton
- Rack specification: 19-inch standard 42U rack equipped with ≥8 pairs of adjustable upper & lower L-shaped brackets
- Operating temperature range: -40℃~+80℃ (Full series)
- Service life: ≥15 years under normal outdoor environment
9.2 UPS Uninterruptible Power Supply
- Optional rated capacities: 1KVA/800W, 3KVA/2400W, 6KVA/4800W
- Operation mode: Online double-conversion with pure sine wave output
- Input voltage range: AC220V±10% (Basic), AC220V±15% (Standard), AC220V±20% (High-end)
- Output voltage precision: ≤±2% (Basic), ≤±1% (Standard), ≤±0.5% (High-end)
- Endurance time: ≥30min (Basic), ≥60min (Standard), ≥120min (High-end)
- Protection functions: Overload, short circuit, overvoltage, undervoltage, over-temperature and low battery protection integrated
9.3 Industrial Cabinet Air Conditioner
- Optional cooling capacities: 800W (Standard), 1200W (Intelligent variable frequency)
- Rated voltage: AC220V±10%
- Temperature control range: 0℃~+40℃ (Standard), -20℃~+50℃ (Intelligent)
- Dehumidification capacity: ≥0.5kg/h (Standard), ≥1.0kg/h (Intelligent)
- Protection grade: ≥IP55 (Standard), ≥IP65 (Intelligent)
- Noise level: ≤50dB (Standard), ≤45dB (Intelligent)
9.4 Environment Monitoring Host
- Supported sensor access channels: ≥4 channels (Basic), ≥8 channels (Standard), ≥16 channels (Intelligent)
- Communication interfaces: Support RS485/Ethernet (Basic); RS485/Ethernet/4G (Standard); RS485/Ethernet/4G/5G (Intelligent)
- Alarm modes: Local audible & visual alarm (Basic); SMS/APP alarm (Standard); SMS/APP/phone linkage alarm (Intelligent)
- Data storage duration: ≥3 months (Basic), ≥1 year (Standard), ≥3 years (Intelligent)
- Power supply voltage: DC12V (Basic), DC24V (Standard & Intelligent)
9.5 Temperature & Humidity Sensor
- Temperature measuring range: -20℃~+60℃ (Basic), -40℃~+80℃ (Standard), -50℃~+85℃ (Ultra-high Precision)
- Humidity measuring range: 0~100%RH (Full series)
- Temperature measuring precision: ≤±0.5℃ (Basic), ≤±0.3℃ (Standard), ≤±0.1℃ (Ultra-high Precision)
- Humidity measuring precision: ≤±3%RH (Basic), ≤±2%RH (Standard), ≤±1%RH (Ultra-high Precision)
- Output signal: RS485 (Basic/Standard); RS485/Ethernet/Wireless (Ultra-high Precision)
- Protection grade: ≥IP55 (Basic), ≥IP65 (Standard), ≥IP67 (Ultra-high Precision)
10. Customized Solutions for Different Scenarios
10.1 ETC Cabinet Solution for Inland Dry Regions
- Pain Points: High temperature, sand dust, large day-night temperature difference, no salt spray and low rainfall
- Configuration Scheme: Adopt Basic low-end or Standard mid-range IP55 cabinet, matched with 1KVA/3KVA UPS, cooling fan / 800W air conditioner, basic environment monitoring and single/three-level lightning protection
- Advantages: High cost performance, meeting high temperature and dustproof demands with reduced investment
10.2 ETC Cabinet Solution for Rainy & Humid Regions
- Pain Points: Heavy rain, high humidity, internal condensation, mosquito infestation, prone to water leakage and short circuits
- Configuration Scheme: Adopt Standard mid-range IP65 cabinet, matched with 3KVA UPS, 800W dehumidifying air conditioner, standard environment monitoring with water immersion sensor, three-level lightning protection and full waterproof sealing components
- Advantages: Excellent waterproof, moisture-proof and anti-condensation performance to eliminate hidden risks of water leakage and short circuits with high stability
10.3 ETC Cabinet Solution for Coastal Salt Spray Regions
- Pain Points: Heavy salt spray, strong corrosion, typhoons, high humidity leading to rapid equipment corrosion and damage
- Configuration Scheme: Adopt Intelligent high-end IP67 304 stainless steel cabinet, matched with 6KVA UPS, 1200W variable frequency air conditioner, full-sensor intelligent environment monitoring, four-level lightning protection, photovoltaic auxiliary power supply and anti-corrosion coating
- Advantages: Super anti-corrosion, typhoon resistance and long power backup, adapting to severe salt spray environments with extended service life
10.4 ETC Cabinet Solution for Plateau & Frigid Regions
- Pain Points: Extremely low temperature, oxygen deficiency, strong ultraviolet radiation, drastic day-night temperature difference, prone to low-temperature equipment shutdown and aging
- Configuration Scheme: Adopt Standard/High-end IP65/IP67 cabinet, matched with 3KVA/6KVA UPS, air conditioner + electric heater dual system, anti-condensation device, wide-temperature sensors, three/four-level lightning protection and anti-ultraviolet coating
- Advantages: Withstand ultra-low temperature, eliminate condensation and resist ultraviolet radiation to guarantee stable equipment operation under frigid conditions
10.5 Intelligent Operation & Maintenance Solution for Smart Expressways
- Pain Points: Scattered sites, unattended operation, high maintenance costs and slow fault response
- Configuration Scheme: Full set of intelligent high-end products including IP67 cabinet, 6KVA UPS, 1200W variable frequency air conditioner, 5G intelligent environment monitoring, HD capture camera, photovoltaic power supply and AI intelligent analysis platform
- Advantages: Unattended operation, remote intelligent maintenance, automatic fault alarms and intelligent data analysis, drastically cutting maintenance costs and improving management efficiency
11. Application Cases
11.1 Mainline ETC Gantry Project of a Provincial Expressway
- Project Overview: Constructed in 2023, covering 1,200km provincial expressway mainline with 350 sets of ETC gantry cabinets including gantry-mounted and roadside floor-mounted types
- Configuration Scheme: KITOZER Standard mid-range dual-compartment IP65 ETC cabinet, matched with 3KVA UPS, 800W air conditioner, standard environment monitoring and three-level lightning protection
- Application Effect: Stable operation for 3 consecutive years without water leakage, corrosion or equipment breakdown, adapting to local rainy and humid climate. The maintenance cost was reduced by 60% while ensuring uninterrupted operation of ETC toll collection system.
11.2 Coastal Seaside Expressway ETC Project
- Project Overview: Constructed in 2022, 80km coastal expressway under severe salt spray environment with 65 sets of ETC cabinets requiring high anti-corrosion and protection performance
- Configuration Scheme: KITOZER Intelligent high-end triple-compartment IP67 304 stainless steel cabinet, matched with 6KVA UPS, 1200W variable frequency air conditioner, intelligent environment monitoring, four-level lightning protection and photovoltaic auxiliary power supply
- Application Effect: 4 years of stable operation without rust or corrosion damage, resisting multiple typhoons and heavy rainstorms with zero equipment failure under extreme weather. Expected service life of equipment exceeds 15 years.
11.3 Western Plateau Expressway ETC Project
- Project Overview: Constructed in 2024, 150km expressway at altitude of 3,500m with ultra-low temperature and strong ultraviolet radiation, deploying 42 sets of ETC cabinets
- Configuration Scheme: KITOZER Standard mid-range IP65 cabinet, matched with 3KVA UPS, air conditioner & electric heater combined system, wide-temperature sensors, three-level lightning protection and anti-ultraviolet coating
- Application Effect: Adaptable to extreme temperature range of -30℃ ~ +45℃, equipment starts normally under ultra-low temperature without condensation or shutdown faults, guaranteeing stable operation of plateau ETC system.
11.4 Urban Express Road ETC Toll Collection Project
- Project Overview: Constructed in 2023, urban express road with 28 sets of lane ETC cabinets requiring compact size, easy deployment and cost-effectiveness
- Configuration Scheme: KITOZER Basic low-end single-compartment IP55 cabinet, matched with 1KVA UPS, cooling fan, basic environment monitoring and single-level lightning protection
- Application Effect: Fast on-site deployment with low total investment, adapting to urban high temperature and sand dust environment. Ultra-low failure rate after 2 years of stable operation, fully meeting urban ETC toll collection demands.
12. Common Equipment Faults & Maintenance Guide
12.1 Common Faults & Troubleshooting of Outdoor ETC Cabinet
- Water leakage through cabinet door
- Root Causes: Aging sealing strip, deformed cabinet door, blocked drainage holes
- Solutions: Replace sealing strip; calibrate deformed door frame; clear blocked bottom drainage holes; reapply waterproof sealant where sealant falls off
- Routine Maintenance: Inspect sealing strips and drainage holes quarterly; replace sealing strips annually
- Cabinet rust & corrosion
- Root Causes: Unsuitable material for environment, damaged surface coating, salt spray/humidity erosion
- Solutions: Polish and reapply anti-corrosion coating for minor corrosion; replace cabinet for severe corrosion; switch to 304 stainless steel cabinet for coastal areas
- Routine Maintenance: Inspect surface coating semi-annually and repair scratches timely; clean salt spray and dust monthly for coastal deployed cabinets
- Malfunctioning door lock (stuck opening/closing)
- Root Causes: Aging lock mechanism, foreign blockage, mechanical failure, power cut for electronic locks
- Solutions: Clear foreign matters in lock hole; lubricate mechanical lock core; inspect power supply and wiring of electronic lock, restart or replace lock if damaged
- Routine Maintenance: Inspect door locks quarterly, lubricate mechanical locks regularly, check power supply and wiring of electronic locks
12.2 Common Faults & Troubleshooting of UPS Uninterruptible Power Supply
- UPS fails to switch to battery mode during mains power outage
- Root Causes: Damaged batteries, loose battery wiring, UPS mainboard failure, abnormal mains detection circuit
- Solutions: Measure battery voltage and replace damaged batteries; fasten loose battery cables; restart UPS and replace mainboard if fault persists
- Routine Maintenance: Check battery voltage and wiring monthly; conduct full charge-discharge test quarterly; replace batteries upon reaching 5-8 year service life
- Frequent overload protection alarms of UPS
- Root Causes: Total load power exceeds UPS rated capacity, short circuit of terminal equipment, internal UPS failure
- Solutions: Disconnect non-critical loads to reduce total power; troubleshoot short-circuited terminal equipment; restart UPS and repair if fault remains
- Routine Maintenance: Forbid overloaded operation; inspect load wiring regularly to prevent short circuits
- Abnormal output voltage causing terminal equipment shutdown
- Root Causes: Malfunctioned UPS voltage stabilization circuit, excessive mains voltage fluctuation, abnormal load equipment
- Solutions: Stabilize mains input voltage; disconnect loads one by one to locate faulty equipment; repair or replace UPS
- Routine Maintenance: Avoid deployment in areas with violent grid voltage fluctuation; test UPS voltage stabilization performance regularly
12.3 Common Faults & Troubleshooting of Industrial Cabinet Air Conditioner
- Air conditioner stops cooling leading to over-temperature inside cabinet
- Root Causes: Power supply failure, damaged compressor, refrigerant leakage, clogged filter screen, faulty temperature controller
- Solutions: Inspect air conditioner power supply and wiring; clean clogged filter screen; refill refrigerant; repair or replace compressor/temperature controller
- Routine Maintenance: Clean filter screen monthly; inspect refrigerant and wiring quarterly; maintain compressor and replenish lubricant annually
- Air conditioner fails to heat under low temperature environment triggering low-temperature alarm
- Root Causes: Damaged electric heater, faulty temperature controller, broken wiring, incorrect operation mode setting
- Solutions: Switch air conditioner to heating mode; inspect heater and wiring, replace damaged parts; repair temperature controller
- Routine Maintenance: Full inspection of heating system before winter; test heating function regularly
- Air conditioner internal water leakage causing high cabinet humidity
- Root Causes: Blocked drainage hole, damaged drainage pipe, accumulated water in condensate tray, unlevel installation
- Solutions: Clear drainage hole blockage; replace cracked drainage pipe; clean condensate tray; adjust air conditioner to horizontal installation
- Routine Maintenance: Inspect drainage system monthly and clear blocked holes; ensure horizontal installation during equipment deployment
12.4 Common Faults & Troubleshooting of Environment Monitoring System
- No data feedback from sensors leading to abnormal monitoring
- Root Causes: Damaged sensors, broken/short-circuited wiring, abnormal power supply, communication failure
- Solutions: Inspect sensor power supply and wiring; restart faulty sensors; troubleshoot communication interfaces and protocols; replace damaged sensors
- Routine Maintenance: Inspect sensor status and wiring monthly; calibrate sensor precision quarterly
- Offline monitoring host with inaccessible remote control
- Root Causes: Power cut of host, network failure, IP address conflict, damaged host mainboard
- Solutions: Restore power supply for host; troubleshoot network wiring and switch; reset IP address; restart host and replace mainboard if fault persists
- Routine Maintenance: Inspect host power supply and network monthly; back up host configuration regularly and upgrade firmware timely
- False or missing alarm signals
- Root Causes: Drifted sensor precision, unreasonable alarm threshold settings, host internal failure, signal interference
- Solutions: Recalibrate sensors; adjust alarm threshold values; eliminate electromagnetic interference sources; repair monitoring host
- Routine Maintenance: Calibrate sensor precision quarterly; optimize alarm thresholds periodically; shield external signal interference
12.5 Overall Equipment Maintenance Schedule
- Monthly Daily Maintenance
- Inspect cabinet appearance, sealing performance, door locks and drainage holes
- Check UPS voltage, battery status and indicator lights
- Verify air conditioner operation status, filter screen and drainage system
- Confirm environment monitoring host, sensor data and communication connectivity
- Clean dust and debris on cabinet exterior
- Quarterly Maintenance (Every 3 Months)
- Full inspection of cabinet anti-corrosion coating and repair scratched areas
- UPS full charge-discharge test and battery parameter calibration
- Deep cleaning of air conditioner, refrigerant and compressor inspection
- Sensor precision calibration and full alarm function test
- Fasten all wiring terminals and interfaces to prevent loose contact
- Annual Maintenance (Every 12 Months)
- Replace aging cabinet accessories including sealing strips
- UPS battery performance test and replacement of expired batteries
- Comprehensive air conditioner maintenance, compressor lubrication and refrigerant refilling
- Environment monitoring host firmware upgrade and configuration backup
- Surge protector performance test and replacement of aging modules
- Long-term Shutdown Maintenance (Over 1 Month)
- Cut off power supply for all internal cabinet equipment and disconnect mains input
- Clean cabinet interior and maintain dry environment
- Fully charge UPS batteries and conduct regular supplementary charging to avoid damage from power depletion
- Close and lock cabinet door tightly for dust and moisture sealing
13. Factory Strength & After-sales Service Commitment
13.1 Factory Strength
KITOZER boasts 15 years of R&D and production experience in outdoor cabinets, ranking as a leading domestic manufacturer of intelligent traffic outdoor equipment. Our factory is located in Guangzhou, Guangdong Province, covering a total area of 20,000㎡ with modern production workshops, advanced production equipment and testing instruments, achieving an annual output capacity of 50,000 outdoor cabinets and 100,000 sets of supporting equipment.
- R&D Team: Over 50 professional R&D engineers covering mechanical, electronic, software and communication fields with abundant outdoor equipment development experience, holding more than 30 patented technologies to continuously innovate and satisfy customized customer demands.
- Production Equipment: Imported German CNC bending machines, laser cutting machines, automatic spraying production lines and welding robots deliver high automation, high product precision and consistent quality.
- Testing Capacity: National-standard laboratory with full test capabilities for high-low temperature, vibration, waterproof/dustproof, salt spray and lightning protection tests. All products pass strict factory testing to guarantee reliable quality.
- Quality Management System: Certified with ISO9001 Quality Management System, ISO14001 Environmental Management System and ISO45001 Occupational Health & Safety Management System, implementing stringent quality control standards complying with national and industrial specifications.
- Supply Chain Advantages: Complete supply chain system adopting internationally renowned brand core components for stable reliability; large-scale procurement delivers prominent cost advantages and high cost performance.
13.2 After-sales Service Commitment
Adhering to the service philosophy of “Customer First, Service Supreme”, KITOZER establishes a full-lifecycle after-sales service system to ensure smooth project implementation and stable equipment operation for all customers.
- Warranty Service: All products enjoy 3-year free warranty (5-year warranty for core components). Non-artificial damage during warranty period qualifies for free repair or spare part replacement; lifelong maintenance service with only material cost charged after warranty expiration.
- Technical Support: 7×24-hour technical support hotline for rapid response to customer consultation and fault reports; remote technical assistance via phone, video and remote desktop to resolve technical issues promptly; on-site engineer dispatch for installation guidance, fault troubleshooting and technical training upon demand.
- Installation & Commissioning: Free provision of product installation drawings and instructional videos; professional engineers dispatched to site to guide installation and commissioning, ensuring normal equipment operation; assist customers in system joint debugging and acceptance testing.
- Technical Training: Free professional training covering installation, operation, maintenance and fault diagnosis via on-site or online sessions to enable customer operation & maintenance staff full proficiency.
- Spare Parts Supply: Complete spare parts warehouse with core components in stock for fast delivery; free standby spare parts supplied within warranty period to shorten downtime; long-term stable spare parts supply for equipment lifelong operation.
- Regular On-site Inspection: Semi-annual free on-site inspection service within warranty period to check equipment operating status, eliminate potential hidden faults and deliver inspection reports with optimization suggestions.
- Rapid Response Mechanism: Fault report response within 2 hours; general faults resolved within 4 hours; complete solution provided within 24 hours for complex faults; engineers arrive at domestic project sites within 48 hours for on-site treatment.
14. Conclusion
As the core infrastructure of expressway ETC gantry systems, the stability and reliability of outdoor ETC cabinets directly determine the normal operation of ETC toll collection systems and road network traffic efficiency. KITOZER outdoor ETC cabinet solutions, developed based on 15 years of industry experience and tailored to extreme outdoor operating conditions, deliver full-series high-protection, high-reliability, easy-to-deploy and easy-to-maintain products covering system design, product configuration, technical parameters and maintenance guidelines. Customized schemes are available to fit inland, rainy coastal, plateau and other diverse operating scenarios.
Adopting modular integrated design, all KITOZER products pass rigorous quality testing with outstanding strengths including powerful customization capability, complete OEM/ODM service, strict confidentiality, fast spot delivery and full-range product portfolio. Supported by comprehensive after-sales service covering full equipment lifecycle, our solutions facilitate the construction of smart expressways, accelerate intelligent and digital upgrading of the transportation industry, and provide more efficient, convenient and safe travel services for the public.
In the future, KITOZER will continue deepening the intelligent transportation sector through persistent R&D innovation, optimized product performance and upgraded service quality, delivering superior products and integrated solutions to drive high-quality development of the smart transportation industry.
15. Search Keywords, SEO Titles & Tags
15.1 Search Keywords
Outdoor ETC cabinet, ETC outdoor integrated cabinet, expressway ETC cabinet, ETC gantry intelligent cabinet, outdoor intelligent cabinet, ETC cabinet solution, KITOZER ETC cabinet, outdoor ETC cabinet configuration list, ETC cabinet technical parameters, ETC cabinet application cases, outdoor cabinet manufacturer, intelligent traffic cabinet, expressway outdoor cabinet, ETC cabinet maintenance guide, IP65 ETC cabinet, IP67 ETC cabinet, coastal ETC cabinet, plateau ETC cabinet
15.2 SEO Titles
- KITOZER Outdoor ETC Cabinet Solution – Expressway ETC Gantry Intelligent Cabinet
- Outdoor ETC Cabinet Manufacturer – Integrated ETC Cabinet – Intelligent Traffic Outdoor Cabinet
- ETC Outdoor Integrated Cabinet Configuration List, Technical Parameters & Application Cases
- Expressway ETC Cabinet – IP65/IP67 Protection – Customizable Outdoor Cabinet
- Smart Expressway ETC Cabinet Solution – Unattended Intelligent Operation & Maintenance
15.3 SEO Description
With 15 years of R&D and manufacturing experience in outdoor ETC cabinets, KITOZER provides full integrated solutions for expressway ETC gantry intelligent cabinets, including IP55/IP65/IP67 protection cabinets, UPS, air conditioners and environment monitoring equipment. Customization supported for inland, coastal and plateau scenarios. Direct supply from factory with reliable quality and complete after-sales service.
15.4 Tags
#OutdoorETCCabinet #ETCOutdoorIntegratedCabinet #ExpresswayETCCabinet #ETCGantryIntelligentCabinet #OutdoorIntelligentCabinet #ETCCabinetSolution #KITOZER #IntelligentTrafficCabinet #OutdoorCabinetManufacturer #IP65Cabinet #IP67Cabinet