Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER

High and Low Voltage Power Distribution and Lightning Protection

I. Search Keywords, SEO and Tags

1.1 Core Search Keywords (Adapted for External Independent Websites, Mainly in Chinese, Focusing on Technical Core)

High and low voltage power distribution technical solution, reactive power compensation technology application, grounding lightning protection system design, high and low voltage power distribution system configuration, reactive power compensation equipment parameters, grounding lightning protection technical specifications, high and low voltage power distribution operation and maintenance plan, reactive power compensation energy-saving technology, grounding lightning protection engineering construction, high and low voltage power distribution system principle diagram, reactive power compensation bid control parameters, grounding lightning protection equipment selection

1.2 SEO Optimization Points (Adapted to External Search Habits to Improve Inclusion Rate)

1. Natural Keyword Distribution: Control the density of core keywords in the full text at 3%-5%, and each core module (system introduction, parameters, solution, etc.) contains 2-3 core keywords to avoid stacking;

2. Title Optimization: The main title includes three core technical keywords, and each secondary and tertiary title is closely related to the core content of the corresponding module, integrating relevant keywords;

3. Content Adaptation: Focus on technical professionalism and practicality, highlight core contents such as system configuration, parameters, solutions, and cases, to meet the technical query needs of external users;

4. Tag Association: Tags are highly matched with keywords, covering multiple dimensions such as technology, products, applications, and operation and maintenance, to improve search relevance.

1.3 Tags (Adapted for External Independent Websites, Facilitating Classification Retrieval and Inclusion)

High and low voltage power distribution, reactive power compensation, grounding lightning protection, power distribution system, compensation technology, lightning protection and grounding, power distribution equipment, compensation equipment, lightning protection equipment, technical solution, equipment parameters, bid control parameters, application cases, technical Q&A, energy-saving power distribution, safe lightning protection

II. Overall System Introduction

This solution integrates three core technologies: high and low voltage power distribution technology, reactive power compensation technology, and grounding lightning protection technology, forming a complete “power supply – energy saving – protection” integrated system. It aims to solve three core problems in various scenarios: power transmission, power quality optimization, and equipment and personnel safety protection, ensuring the stable, efficient, safe and long-term operation of the power system. The three technologies work synergistically: the high and low voltage power distribution system, as the core carrier of power transmission, is responsible for reasonably distributing grid power to various electrical equipment to achieve efficient power transmission; the reactive power compensation system, as the key support for power quality optimization, improves power factor, reduces line loss, and stabilizes grid voltage by accurately compensating reactive power; the grounding lightning protection system, as the last line of defense for safety protection, discharges lightning energy, eliminates static accumulation, and ensures the safety of equipment and personnel through scientific grounding design and lightning protection device configuration. The three complement each other, covering the entire process of the power system from transmission, optimization to protection, adapting to the core needs of various medium and large-scale power consumption scenarios, and complying with relevant national and industrial technical standards.

2.1 Introduction to High and Low Voltage Power Distribution System

The high and low voltage power distribution system is a core component of the power system. It is mainly responsible for stepping down the high-voltage power input from the grid (usually 6kV ~ 35kV) to low-voltage power (not exceeding 1kV) through a transformer, and then reasonably distributing it to various electrical loads through switchgear, protection devices, distribution lines, etc., while realizing the control, monitoring and protection of the power system. The system is divided into high-voltage power distribution part and low-voltage power distribution part. The high-voltage power distribution part is mainly composed of high-voltage switchgear, high-voltage circuit breakers, high-voltage isolating switches, current transformers, voltage transformers and other equipment. It undertakes the tasks of receiving, converting and initial distributing high-voltage power, ensuring the stability and safety of high-voltage side power transmission; the low-voltage power distribution part is mainly composed of low-voltage switchgear, low-voltage circuit breakers, contactors, fuses, residual current protectors and other equipment. It is responsible for accurately distributing the stepped-down low-voltage power to terminal electrical equipment, and protecting the low-voltage side circuit from overload, short circuit, leakage, etc., to avoid equipment damage and safety accidents.

The system follows the design principles of “safety and reliability, high efficiency and energy saving, flexible expansion, and easy operation and maintenance”, adopts a standardized and modular structure, and can flexibly adjust the system configuration according to the capacity, type and distribution of electrical loads to adapt to the power consumption needs of different scenarios. Its core function is to realize the safe transmission and reasonable distribution of electrical energy, reduce energy loss, and ensure the normal operation of various electrical equipment. It is an indispensable power infrastructure for industrial production, commercial buildings, public facilities and other scenarios. The electrical equipment in the high and low voltage power distribution system is divided into primary equipment and secondary equipment according to the nature of the circuit to which they belong. Primary equipment is used for transmitting and distributing electrical energy, and secondary equipment is used for controlling, indicating, measuring and protecting the primary circuit and equipment operation.

2.2 Introduction to Reactive Power Compensation System

The reactive power compensation system is a key system for optimizing power quality and reducing power loss. It mainly accurately compensates for the reactive power generated by inductive loads (such as motors, transformers, electric welding machines, etc.) in the power system. By configuring reactive power compensation equipment, it injects corresponding capacitive reactive power into the grid to offset the impact of inductive reactive power, thereby improving grid power factor, stabilizing grid voltage, reducing line and transformer losses, and improving the power supply efficiency and transmission capacity of the power system.

The core working principle of the system is to use the capacitive characteristics of compensation components such as capacitors and reactors to offset the inductive characteristics of inductive loads, so that the reactive power in the power system tends to balance, reduce the transmission of reactive power in the grid, and reduce line voltage drop and power loss. The system adopts an intelligent control mode, which can real-time monitor grid parameters such as power factor, voltage and current, and automatically switch compensation components according to load changes to ensure compensation accuracy and stability, and avoid over-compensation or under-compensation. At the same time, the system can be equipped with harmonic suppression function, which can suppress the amplification of 3rd, 5th and other harmonics by configuring tuning reactors and other equipment, ensure that the power quality meets relevant standard requirements, and meet the strict requirements of different scenarios for power quality. Reactive power compensation is divided into centralized compensation and local compensation, which can be flexibly selected according to the load distribution characteristics to ensure compensation effect while taking into account economy and practicality.

2.3 Introduction to Grounding Lightning Protection System

The grounding lightning protection system is a core protection system to ensure the safety of the power system and electrical equipment. It is mainly composed of two parts: the grounding system and the lightning protection system. It collaboratively realizes three functions: lightning energy discharge, static elimination, and equipment grounding protection, preventing equipment damage, fires, personnel electric shock and other safety accidents caused by lightning overvoltage, static accumulation, equipment leakage, etc.

The core function of the grounding system is to reliably connect the metal shell of power equipment, the grounding conductor of lines, etc. with the earth to form a low-resistance discharge channel. When equipment leakage or static accumulation occurs, the leakage current or static electricity can be quickly discharged to the earth to ensure the safety of equipment and personnel; at the same time, it provides a reliable grounding support for the lightning protection system to ensure that lightning energy can be smoothly discharged. The lightning protection system is mainly composed of lightning receiving devices, down conductors, surge protectors (SPD) and other equipment. Lightning receiving devices (lightning rods, lightning strips, lightning nets, etc.) are used to intercept direct lightning. Down conductors are used to transmit the lightning energy intercepted by the lightning receiving devices to the grounding system. Surge protectors are used to suppress overvoltage generated by lightning induction and protect the electronic components and lines of power equipment from damage.

The system adopts the design principle of combining “external lightning protection + internal lightning protection”. External lightning protection is used to defend against direct lightning and protect buildings and outdoor equipment; internal lightning protection is used to reduce the electromagnetic effect generated by lightning current and protect indoor equipment and lines. The design of the grounding lightning protection system follows the principle of equal voltage and equipotential. It shares a set of grounding electrodes for working grounding, protective grounding, lightning protection grounding, etc., forming a common grounding system, balancing potential, reducing step voltage, ensuring the comprehensiveness and reliability of the protection effect, adapting to the protection needs of different environments (such as outdoor, indoor, humid environments, etc.), and complying with relevant national and industrial lightning protection and grounding specifications and standards. The system grounding resistance must be strictly controlled according to scene requirements to ensure that lightning energy and leakage current can be discharged quickly and safely. At the same time, regular inspection and maintenance are carried out to ensure the long-term stable operation of the system.

III. System Configuration List

Note: All equipment brands in this list are KITOZER. No prices, local or company-related information will be displayed throughout. It only includes equipment name, model specification, unit, quantity (quantity can be flexibly adjusted according to actual scenarios), adapting to the needs of high and low voltage power distribution, reactive power compensation, and grounding lightning protection integrated system.

System CategoryEquipment NameModel Specification (Reference)UnitQuantityRemarks
High and Low Voltage Power Distribution SystemHigh Voltage SwitchgearKITOZER-KYN28-12, Rated Voltage 12kV, Rated Current 630ASetAs NeededMetal Clad Type, with Five-prevention Function, Including High Voltage Circuit Breaker and Isolating Switch
Power TransformerKITOZER-SCB13, Rated Capacity 1250kVA, High Voltage 10kV, Low Voltage 0.4kVSetAs NeededDry-type Transformer, Insulation Class F, Protection Class IP23, Energy Efficiency Level 1
Low Voltage SwitchgearKITOZER-GCS, Rated Voltage 0.4kV, Rated Current 4000ASetAs NeededDrawer-type Structure, Including Incoming Line Cabinet, Feeder Cabinet and Tie Cabinet
Low Voltage Circuit BreakerKITOZER-CM1, Rated Current 100A-4000A, Breaking Capacity 50kASetAs NeededUsed for Overload and Short Circuit Protection of Low Voltage Circuits
Current TransformerKITOZER-LZZBJ9, Rated Voltage 10kV, Transformation Ratio 100/5ASetAs NeededUsed for Current Measurement and Protection
Voltage TransformerKITOZER-JDZ10, Rated Voltage 10kV/0.1kVSetAs NeededUsed for Voltage Measurement and Protection
Residual Current ProtectorKITOZER-RCBO, Rated Current 32A-100A, Residual Operating Current 30mASetAs NeededUsed for Leakage Protection of Low Voltage Circuits to Prevent Personnel Electric Shock
Power Distribution Bus DuctKITOZER-BMC, Rated Current 630A-2500A, Protection Class IP54MeterAs NeededUsed for Low Voltage Power Transmission, Dense Structure
Reactive Power Compensation SystemReactive Power Compensation ControllerKITOZER-ARC-28, Rated Voltage 0.4kV, Supporting RS485 CommunicationSetAs NeededIntelligent Control, Automatic Switching of Compensation Capacitors, Supporting Harmonic Monitoring
Self-healing Shunt CapacitorKITOZER-BKMJ, Rated Voltage 450V, Capacity 10kvar-30kvarSetAs NeededMetallized Film Material, Capacity Deviation ≤±5%, Good Self-healing Performance
Tuning ReactorKITOZER-CKSG, Rated Voltage 0.4kV, Reactance Rate 7%-14%SetAs NeededSuppressing Harmonic Amplification, Suitable for Capacitor Banks
Capacitor Switching SwitchKITOZER-KCS, Rated Voltage 0.4kV, Rated Current 40A-100ASetAs NeededContactless Switching, Response Time ≤30ms, Reducing Switching Impact
Discharge CoilKITOZER-FDGN, Rated Voltage 0.4kV, Capacity 0.5kVASetAs NeededUsed for Discharging Capacitor Banks to Ensure Equipment Safety
Harmonic DetectorKITOZER-HB-600, Rated Voltage 0.4kV, Measurement Accuracy 0.5 ClassSetAs NeededReal-time Monitoring of Grid Harmonic Content, THDi ≤8%
Grounding Lightning Protection SystemLightning RodKITOZER-FL-1, Height 3m-10m, Material Hot-dip Galvanized SteelPieceAs NeededUsed for Intercepting Direct Lightning, Protection Radius Adapts to Scene Needs
Lightning StripKITOZER-FL-2, Specification Φ12mm, Material Hot-dip Galvanized Round SteelMeterAs NeededUsed for Direct Lightning Protection of Building Roofs, Cooperating with Lightning Rods
Down ConductorKITOZER-FL-3, Specification 25×4mm, Material Hot-dip Galvanized Flat SteelMeterAs NeededConnecting Lightning Receiving Device and Grounding Electrode, Conducting Lightning Energy
Vertical Grounding ElectrodeKITOZER-JD-1, Length 2.5m, Specification Φ16mm, Material Copper-clad SteelPieceAs NeededBuried Underground, Forming Grounding Grid, Grounding Resistance ≤4Ω
Horizontal Grounding ElectrodeKITOZER-JD-2, Specification 40×4mm, Material Hot-dip Galvanized Flat SteelMeterAs NeededConnecting Vertical Grounding Electrodes, Forming Closed Grounding Grid
Surge Protector (SPD)KITOZER-SPD-1, Rated Voltage 10kV/0.4kV, Current Capacity 20kA-60kASetAs NeededDivided into High Voltage and Low Voltage Types, Suppressing Lightning Overvoltage
Equipotential Connection Terminal BlockKITOZER-DW-1, Specification 300×100mm, Material Copper BarPieceAs NeededRealizing Equipotential Connection of Equipment, Reducing Potential Difference
Auxiliary EquipmentPower CableKITOZER-YJV, Specification 1×16mm²-3×240+1×120mm²MeterAs NeededCopper Core XLPE Material, Used for Power Transmission
Grounding Resistance TesterKITOZER-CZ-1, Measurement Range 0-100Ω, Accuracy ±1%SetAs NeededUsed for Detecting Grounding System Resistance Value
Control CableKITOZER-KVVP, Specification 4×1.5mm²-16×1.5mm²MeterAs NeededShielded Material, Used for Control Signal Transmission

IV. System Principle Diagram (Detailed Text Description, Adapted for External Network Display, Clear and Easy to Understand)

Note: This system principle diagram is a collaborative principle diagram of high and low voltage power distribution, reactive power compensation, and grounding lightning protection integration. It describes the connection relationship, signal flow, energy transmission and protection logic of each equipment in detail in text. No pictures are needed to ensure that external users can clearly understand the system structure and workflow, complying with relevant technical specifications.

4.1 Overall Principle Diagram Framework

High-voltage power from the grid (10kV/35kV) is connected to the high-voltage switchgear of the high and low voltage power distribution system through high-voltage incoming cables. After initial control and monitoring by high-voltage circuit breakers, isolating switches, current transformers, voltage transformers and other equipment, it is connected to the power transformer, which steps down the high-voltage power to low-voltage power (0.4kV); the stepped-down low-voltage power is connected to the low-voltage switchgear. After protection and distribution by low-voltage circuit breakers, residual current protectors and other equipment, part of it is transmitted to terminal electrical loads, and the other part is connected to the reactive power compensation system. The reactive power compensation controller real-time monitors grid parameters and automatically controls the switching of compensation components to realize reactive power compensation; the grounding lightning protection system is linked with the high and low voltage power distribution system and the reactive power compensation system throughout. It intercepts direct lightning through lightning receiving devices, conducts lightning energy through down conductors, discharges lightning energy to the earth through the grounding grid, suppresses lightning-induced overvoltage through surge protectors, and realizes equipotential connection of various equipment through equipotential connection terminal blocks, forming a comprehensive safety protection system to ensure the stable and safe operation of the entire system.

4.2 Detailed Description of High and Low Voltage Power Distribution System Principle Diagram

1. High-voltage Side Circuit: The high-voltage power from the grid (10kV) is connected to the incoming line isolating switch of the high-voltage switchgear through high-voltage incoming cables. After being controlled by the opening/closing of the isolating switch, it is connected to the high-voltage circuit breaker. The high-voltage circuit breaker is used to control the on/off of the high-voltage circuit and has overload and short-circuit protection functions; the output end of the circuit breaker is connected to current transformers and voltage transformers. The current transformer is used to measure the high-voltage circuit current, and the voltage transformer is used to measure the high-voltage circuit voltage. The signals of both are transmitted to the monitoring instruments of the high-voltage control cabinet to realize real-time monitoring of high-voltage parameters; then, the high-voltage power is connected to the high-voltage winding of the power transformer to complete the power transmission and control on the high-voltage side.

2. Transformer Circuit: The power transformer adopts a dry-type transformer. The high-voltage winding is connected to high-voltage power, and the high-voltage power is stepped down to 0.4kV low-voltage power through the principle of electromagnetic induction, and the low-voltage winding outputs low-voltage power; the transformer is equipped with a temperature monitoring device and an air-cooling system to real-time monitor the temperature of the transformer winding. When the temperature exceeds the set value, the air-cooling system starts automatically to ensure the stable operation of the transformer; the transformer shell is reliably connected to the grounding system to realize protective grounding and prevent safety accidents caused by transformer leakage.

3. Low-voltage Side Circuit: The 0.4kV low-voltage power output by the low-voltage winding of the transformer is connected to the incoming line cabinet of the low-voltage switchgear. The low-voltage circuit breaker in the incoming line cabinet is used to control the on/off of the low-voltage main circuit and has overload and short-circuit protection functions; the output end of the incoming line cabinet is connected to the bus duct, which distributes the low-voltage power to each feeder cabinet, tie cabinet and reactive power compensation cabinet; the low-voltage circuit breakers and residual current protectors in the feeder cabinet distribute the low-voltage power to various terminal electrical loads (such as motors, lighting equipment, office equipment, etc.) according to load needs. The residual current protector is used to detect the leakage current of the low-voltage circuit. When the leakage current exceeds the set value, it trips automatically to protect the safety of personnel and equipment; the tie cabinet is used to connect multiple low-voltage switchgears to realize the linkage control of the low-voltage circuit and improve the reliability and flexibility of the system; the current, voltage, power and other parameters of the entire low-voltage side circuit are displayed in real time through monitoring instruments for the convenience of operation and maintenance personnel to check.

The high and low voltage power distribution system adopts a single bus section wiring mode. Two high-voltage power sources are mutually standby, and mechanical interlocking and electrical interlocking devices are set to avoid misoperation or mis-paralleling and ensure power supply reliability; the low-voltage side adopts a “radial + trunk” mixed power supply mode. Important loads adopt radial power supply, and ordinary loads adopt trunk power supply, taking into account reliability and economy.

4.3 Detailed Description of Reactive Power Compensation System Principle Diagram

The reactive power compensation system is connected to the bus duct of the low-voltage power distribution system, takes power from the bus duct, and real-time monitors the current, voltage, power factor, harmonic content and other parameters of the bus duct to realize accurate compensation of reactive power. The core circuits of the system are as follows:

1. Monitoring and Control Circuit: The reactive power compensation controller is connected to the low-voltage bus duct, collects the current and voltage signals of the bus duct through current transformers and voltage transformers, real-time calculates the power factor and reactive power demand of the grid, and monitors the grid harmonic content at the same time; the controller has an intelligent judgment function. When the power factor is lower than the set value (usually 0.9) or the reactive power demand reaches the set value, it automatically sends a switching command to control the action of the capacitor switching switch; the controller supports RS485 communication function and can transmit monitoring data to the central control system to realize remote monitoring and control.

2. Compensation Circuit: After receiving the switching command from the controller, the capacitor switching switch automatically switches the self-healing shunt capacitor bank. The capacitor bank is connected in series with the tuning reactor. The tuning reactor is used to suppress grid harmonics, avoid damage to the capacitor due to harmonic overload, and limit the inrush current when the capacitor is switched; the discharge coil is connected in parallel with the capacitor bank. When the capacitor bank is out of operation, the discharge coil quickly discharges the electrical energy in the capacitor to ensure equipment safety; multiple capacitor banks can be flexibly switched according to the reactive power demand to realize stepped compensation, ensure compensation accuracy, stabilize the grid power factor above 0.9, and reduce line loss.

3. Protection Circuit: A fuse and an overvoltage protector are set in the compensation circuit. The fuse is used for short-circuit protection of the capacitor bank. When a short-circuit fault occurs in the capacitor, the fuse fuses quickly to cut off the circuit; the overvoltage protector is used to suppress grid overvoltage and prevent overvoltage from damaging capacitors, reactors and other equipment; the harmonic detector real-time monitors the grid harmonic content. When the harmonic content exceeds the set value (THDi ≤8%), it sends an alarm signal to remind operation and maintenance personnel to handle it in time to ensure that the power quality meets relevant standard requirements.

According to the load distribution characteristics, the reactive power compensation system can adopt a combination of centralized compensation and local compensation. The centralized compensation device is installed in the low-voltage power distribution room, and the local compensation device is installed near the large-capacity inductive load to ensure the compensation effect and further reduce line loss.

4.4 Detailed Description of Grounding Lightning Protection System Principle Diagram

The grounding lightning protection system runs through the entire solution and is reliably connected to all equipment of the high and low voltage power distribution system and the reactive power compensation system to form a comprehensive protection circuit. The core circuits are as follows:

1. Lightning Protection Circuit: The external lightning protection circuit is composed of lightning receiving devices, down conductors and lightning strips. Lightning rods are installed in outdoor equipment areas and building tops, and lightning strips are laid along the edge and ridge of the building roof to intercept direct lightning; both lightning rods and lightning strips are reliably connected to down conductors. The down conductors are made of hot-dip galvanized flat steel, vertically laid on the building wall or equipment bracket, and conduct the lightning energy intercepted by the lightning receiving devices to the grounding grid; the internal lightning protection circuit is composed of surge protectors (SPD). High-voltage surge protectors are installed at the incoming line end of the high-voltage switchgear, low-voltage surge protectors are installed at the incoming line end and feeder end of the low-voltage switchgear, and signal surge protectors are installed in the control circuit to suppress overvoltage generated by lightning induction and prevent overvoltage from damaging the electronic components and lines of equipment; the grounding end of the surge protector is reliably connected to the grounding grid to ensure that lightning overvoltage can be discharged quickly.

2. Grounding Circuit: The grounding grid is composed of vertical grounding electrodes and horizontal grounding electrodes. The vertical grounding electrodes are made of copper-clad steel, vertically buried underground (depth not less than 0.8m). Multiple vertical grounding electrodes are reliably connected through horizontal grounding electrodes (hot-dip galvanized flat steel) to form a closed grounding grid. The grounding resistance of the grounding grid is ≤4Ω (≤1Ω for important scenarios); the metal shells of all equipment in the high and low voltage power distribution system (high-voltage switchgear, low-voltage switchgear, transformers, etc.), the grounding conductors of lines, the equipment shells of the reactive power compensation system, and the grounding ends of the control circuit are all reliably connected to the grounding grid through grounding wires to realize protective grounding; the equipotential connection terminal block is installed in the power distribution room and equipment room, connecting the metal shells, metal brackets, cable shielding layers and other parts of various equipment to realize equipotential connection, reduce the potential difference between equipment during lightning and leakage, and avoid safety accidents caused by arc discharge.

3. Static Discharge Circuit: For equipment that generates static electricity (such as capacitor banks, cable terminals, etc.), its metal shell is connected to the grounding grid through grounding wires to quickly discharge static electricity to the earth, preventing static accumulation from causing fires or equipment damage; a grounding resistance tester interface is set in the grounding circuit to regularly detect the resistance value of the grounding grid to ensure the reliability of the grounding system; the grounding wire adopts yellow-green double-color plastic insulated copper core wire, and aluminum material shall not be used. The grounding wire preferably selects the standard wire supporting the equipment, with a length not exceeding 30m, avoiding coiling. The connection point adopts welding or crimping method to ensure that the contact resistance is less than 0.1Ω, and anti-corrosion treatment is done.

V. Product Technical Parameters (Listed in Detail by System and Equipment, No Price Display, Suitable for External Network Technical Query Needs)

5.1 Technical Parameters of High and Low Voltage Power Distribution System Products

5.1.1 High Voltage Switchgear

1. Rated Voltage: 12kV (Adaptable to 6kV-35kV);

2. Rated Current: 630A-1250A;

3. Short-circuit Withstand Current: 25kA-40kA, Withstand Time 3s;

4. Protection Class: IP3X and Above;

5. Internal Equipment: High Voltage Circuit Breaker, Isolating Switch, Current Transformer, Voltage Transformer, Arrester, etc.;

6. Operation Mode: Manual/Electric Operation, with Five-prevention Function (Preventing Mis-opening and Closing of Circuit Breakers, Preventing Opening and Closing of Isolating Switches with Load, Preventing Hanging Ground Wires with Electricity, Preventing Closing with Ground Wires, Preventing Entering Live Intervals);

7. Insulation Class: F Class;

8. Working Environment: Temperature -20℃~+40℃, Humidity ≤95% (No Condensation);

9. Structure Form: Metal Clad Type, Modular Design, Easy to Install and Maintain;

10. Monitoring Function: Supporting Real-time Monitoring of Current, Voltage, Power and Other Parameters, with Fault Alarm Function.

5.1.2 Power Transformer

1. Model: Dry-type Transformer (SCB13 Series);

2. Rated Capacity: 500kVA-2500kVA (Customizable on Demand);

3. Rated Voltage: High Voltage 10kV (Adaptable to 6kV-35kV), Low Voltage 0.4kV;

4. Voltage Regulation Rate: ≤2.5%;

5. Loss Value: No-load Loss ≤1.2kW, Load Loss ≤6.5kW (Adjusted According to Capacity);

6. Insulation Class: F Class, Maximum Allowable Temperature 155℃;

7. Protection Class: IP23