Park Energy Consumption Monitoring Integrated Solution

Table of Contents

1. System Introduction

The park energy consumption monitoring integrated system is an integrated energy management platform built based on Internet of Things (IoT), big data, artificial intelligence (AI) and digital twin technologies. It focuses on the full-link energy flow of “source-grid-load-storage” within the park, realizing real-time collection, precise metering, intelligent analysis, visual presentation and linkage control of various energy consumption data including electricity, water, gas, heat and cooling capacity. It serves as the core infrastructure for the digital transformation, green and low-carbon operation of parks and the implementation of carbon peaking and carbon neutrality goals.

The system fully complies with national policy standards such as Guidelines for the Construction of Digital Energy Carbon Management Centers in Industrial Enterprises and Parks and Technical Specifications for Online Energy Consumption Monitoring Systems of Key Energy-consuming Units. It breaks data barriers between park Building Automation (BA), enterprise ERP, photovoltaic energy storage, charging piles, fire protection and security systems, and forms a closed-loop management system of “Monitoring-Analysis-Decision-Making-Execution-Optimization”. Through accurate energy consumption monitoring and intelligent scheduling, the system can reduce the comprehensive energy consumption of the park by 10%-30% and cut operation and maintenance costs by more than 20%. Meanwhile, it automatically generates carbon accounting reports and energy consumption statistical statements to meet the demands of government supervision, ESG disclosure and carbon asset management, facilitating the upgrading of park operation from “experience-based management” to data-driven smart operation.

2. System Composition

The park energy consumption monitoring integrated system adopts a three-layer architecture design (Perception Layer – Transmission Layer – Platform Application Layer). Devices at all layers cooperate and interact to cover the whole process of data collection, transmission, storage, analysis, display and control.

2.1 Perception Layer (Data Collection Terminals)

The perception layer acts as the “nerve endings” of the system, deployed in power distribution rooms, building shafts, pipe network nodes, equipment machine rooms and other locations of the park. It is responsible for high-precision collection and preliminary processing of energy consumption data, environmental parameters and equipment status. Core devices include:

  • Power metering equipment: multi-function electric energy meters, smart electric meters, harmonic analyzers, reactive power compensation controllers, monitoring parameters such as voltage, current, power, electric energy, power factor and harmonics.
  • Water/Gas/Heat metering equipment: smart water meters, gas meters, heat meters, cooling capacity meters, supporting pulse, Modbus and other signal outputs.
  • Environmental and status sensors: temperature and humidity sensors, pressure sensors, flow sensors, liquid level sensors, current transformers, voltage transformers.
  • Collection terminals: data collectors, edge computing gateways, realizing multi-protocol data conversion, local caching and breakpoint resume transmission.

2.2 Transmission Layer (Data Communication Network)

The transmission layer undertakes data transmission tasks between the perception layer and the platform application layer, adopting a wired + wireless converged networking mode to guarantee the stability, security and real-time performance of data transmission. Core components:

  • Wired communication: RS485 bus, Ethernet, optical fiber, applicable to fixed points such as power distribution rooms and machine rooms with stable transmission and strong anti-interference performance.
  • Wireless communication: LoRa, NB-IoT, 4G/5G, WiFi, applicable to scattered points, outdoor pipe networks and mobile equipment, featuring flexible deployment and convenient construction.
  • Network security equipment: industrial firewalls, VPN gateways, data encryption modules to prevent data tampering and leakage and ensure communication security.

2.3 Platform Application Layer (Data Center & Management Platform)

The platform application layer is the “brain” of the system, responsible for data storage, calculation, analysis, visual display and intelligent control. Core components:

  • Hardware facilities: servers, storage devices, industrial switches, UPS power supplies, large-screen display systems to guarantee stable operation of the platform.
  • Software platform: energy consumption monitoring management software, data middle platform, AI analysis module, digital twin module, report generation module, remote control module, mobile APP terminal.
  • Integration interfaces: support docking with park BA systems, ERP systems, photovoltaic energy storage systems, charging pile systems and government supervision platforms to realize data sharing and linkage control.

3. System Classification

3.1 Classification by Energy Type

  • Power energy consumption monitoring subsystem: covers power consumption monitoring of park main power distribution, building power distribution, workshop power distribution, public lighting, air conditioning systems and power equipment, supporting three-phase/single-phase metering, harmonic analysis, load forecasting and peak-shifting power management.
  • Water energy consumption monitoring subsystem: monitors consumption of park tap water, industrial water, reclaimed water and rainwater, covering municipal water intake, building water consumption, production water consumption, greening water consumption and sewage discharge nodes, supporting leakage detection and water quota management.
  • Gas energy consumption monitoring subsystem: monitors consumption of natural gas and liquefied petroleum gas, covering gas consumption points such as canteens, boiler rooms and production workshops, supporting leakage alarm and gas consumption analysis.
  • Heat/Cooling capacity energy consumption monitoring subsystem: monitors consumption of park central heating and central air conditioning cooling capacity, covering heat exchange stations, building air conditioning machine rooms and terminal equipment, supporting energy efficiency analysis and temperature linkage control.
  • Comprehensive energy consumption monitoring subsystem: integrates electricity, water, gas, heat and cooling capacity data to generate comprehensive energy consumption reports, energy consumption per unit output value and energy consumption per unit area, supporting carbon accounting and energy efficiency benchmarking.

3.2 Classification by Monitoring Level

  • Park-level energy consumption monitoring: monitors total park energy data (main electric meters, main water meters, main gas meters, etc.) to grasp the overall energy consumption level, energy structure and total carbon emissions of the park.
  • Building-level energy consumption monitoring: monitors energy consumption data of each building in the park, distinguishes energy consumption of public areas, office areas and production areas, and supports building energy efficiency rating and energy consumption allocation.
  • Equipment-level energy consumption monitoring: monitors energy consumption and operating status of key energy-consuming equipment in the park (central air conditioners, air compressors, water pumps, fans, production line equipment, etc.), supporting equipment energy efficiency analysis, fault early warning and energy-saving renovation evaluation.

3.3 Classification by Functional Modules

  • Data collection and metering module: responsible for collection, storage and statistics of all types of energy consumption data, supporting multi-protocol access, data calibration and abnormal data elimination.
  • Visual display module: displays energy consumption data, equipment status and alarm information intuitively through large screens, PC terminals and mobile APPs in the forms of dashboards, curve charts, bar charts, pie charts, topology diagrams and digital twin models.
  • Intelligent analysis and optimization module: based on AI algorithms, realizes energy consumption trend prediction, load analysis, energy efficiency diagnosis, energy-saving suggestions, carbon accounting and carbon footprint tracking.
  • Alarm and operation maintenance module: supports real-time alarms for abnormal energy consumption, equipment faults and parameter out-of-limits (sound and light, SMS, APP push), generates operation and maintenance work orders and fault statistical reports to improve operation and maintenance efficiency.
  • Report and compliance module: automatically generates daily, weekly, monthly and annual reports, as well as energy consumption reports and carbon reports required by government supervision, supporting data export, printing and submission.

4. System Schematic Diagram

4.1 System Architecture Principle

Metering instruments and sensors at the perception layer collect energy consumption data, which are transmitted to edge computing gateways via RS485, LoRa, 4G/5G and other communication methods. The gateways complete data protocol conversion and local caching, then upload data to the data center of the platform application layer through Ethernet/optical fiber. After storage, cleaning and analysis by the data center, the data are presented to users through visual platforms and mobile APPs. Meanwhile, users can send control instructions to realize remote regulation of equipment.

4.2 Data Flow Principle

Energy Consumption → Metering Instruments/Sensors (Data Collection) → Collection Terminals/Gateways (Protocol Conversion & Caching) → Transmission Network (Wired/Wireless) → Data Center (Storage, Analysis & Calculation) → Application Platform (Visualization, Alarm, Report & Control) → Users (Decision-Making, Operation & Maintenance, Management)

4.3 Core Control Principle

The system monitors energy consumption data and equipment operating status in real time. When data exceed thresholds or equipment malfunctions, alarms are automatically triggered and pushed to operation and maintenance personnel. Based on AI algorithms to analyze energy consumption rules, optimization strategies (peak-shifting power consumption, equipment linkage, load regulation, etc.) are generated, and instructions are sent to equipment through the control module to realize intelligent energy consumption optimization and reduce operating costs.

5. Full Product Configuration List (KITOZER Brand, Low/Mid/High Tiers)

5.1 Low-Tier Configuration List (Basic Monitoring, for Small Parks/Simple Buildings)

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1Single-Phase Multi-Function Electric Energy MeterKITOZER-DD862Rated Voltage: 220V; Rated Current: 5(20)A; Accuracy Class: 1.0; Communication: RS485/Modbus-RTU; Frequency: 50Hz; Operating Temp: -20℃~+60℃On-demandSetKITOZERSingle-phase power consumption monitoring
2Three-Phase Multi-Function Electric Energy MeterKITOZER-DT862Rated Voltage: 3×220/380V; Rated Current: 10(40)A; Accuracy Class: 1.0; Communication: RS485/Modbus-RTU; Frequency: 50Hz; Operating Temp: -20℃~+60℃On-demandSetKITOZERThree-phase power consumption monitoring
3Smart Cold Water MeterKITOZER-LXS-15Nominal Diameter: DN15; Accuracy Class: 2.0; Communication: Pulse; Working Pressure: 1.6MPa; Water Temp: 0℃~40℃; Material: CopperOn-demandSetKITOZERTap water consumption monitoring
4Smart Gas MeterKITOZER-G1.6Nominal Flow: 1.6m³/h; Accuracy Class: 1.5; Communication: Pulse; Working Pressure: 0.5MPa; Operating Temp: -10℃~+50℃; Material: Aluminum AlloyOn-demandSetKITOZERGas consumption monitoring
5Data CollectorKITOZER-DC-100Communication Interfaces: 2×RS485; Supported Protocols: Modbus-RTU, Pulse; Power Supply: DC12V; Operating Temp: -20℃~+60℃; Cache: 8MBOn-demandSetKITOZERBasic data collection & protocol conversion
65-Port Industrial SwitchKITOZER-SW-500Ports: 5×10/100Mbps Ethernet; Transmission Distance: 100m; Power Supply: DC24V; Operating Temp: -30℃~+75℃; Protection Class: IP301SetKITOZERBasic network transmission
7Basic Energy Consumption Monitoring SoftwareKITOZER-EMS-BasicFunctions: Data collection, real-time display, historical query, simple reports, basic alarms; Terminals Supported: PC; Max Access Points: ≤50; Deployment: Local1SetKITOZERBasic energy consumption management
81KVA UPS Power SupplyKITOZER-UPS-1000Capacity: 1KVA/600W; Input Voltage: 220V±10%; Output Voltage: 220V±5%; Backup Time: ≥30min; Waveform: Sine Wave1SetKITOZERPower outage backup for equipment

5.2 Mid-Tier Configuration List (Comprehensive Monitoring, for Medium-Sized Parks/Multi-Building Complexes)

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1High-Precision Single-Phase Multi-Function MeterKITOZER-DDSF862Rated Voltage: 220V; Rated Current: 5(60)A; Accuracy Class: 0.5S; Communication: RS485/LoRa/Modbus-RTU; Frequency: 50Hz; Operating Temp: -30℃~+70℃; Harmonic Monitoring SupportedOn-demandSetKITOZERHigh-precision single-phase monitoring with harmonic measurement
2High-Precision Three-Phase Multi-Function MeterKITOZER-DTSF862Rated Voltage: 3×220/380V; Rated Current: 10(80)A; Accuracy Class: 0.5S; Communication: RS485/LoRa/Modbus-RTU; Frequency: 50Hz; Operating Temp: -30℃~+70℃; Harmonic & Reactive Power Measurement SupportedOn-demandSetKITOZERHigh-precision three-phase monitoring with harmonic & reactive power measurement
3Remote Smart Water Meter (Cold & Hot Water)KITOZER-LXSY-20Nominal Diameter: DN20; Accuracy Class: 1.5; Communication: LoRa/Pulse; Working Pressure: 1.6MPa; Water Temp: 0℃~90℃; Material: Stainless Steel; Anti-Inversion FunctionOn-demandSetKITOZERUniversal for cold & hot water, remote data transmission
4Remote Smart Gas MeterKITOZER-G2.5Nominal Flow: 2.5m³/h; Accuracy Class: 1.0; Communication: LoRa/Pulse; Working Pressure: 0.5MPa; Operating Temp: -20℃~+60℃; Material: Aluminum Alloy; Tamper Alarm SupportedOn-demandSetKITOZERRemote monitoring with tamper alarm
5Heat MeterKITOZER-RLM-25Nominal Diameter: DN25; Accuracy Class: 1.0; Communication: RS485/Modbus-RTU; Temp Range: 4℃~95℃; Working Pressure: 1.6MPa; Material: CopperOn-demandSetKITOZERHeat consumption monitoring
6Cooling Capacity MeterKITOZER-CLM-25Nominal Diameter: DN25; Accuracy Class: 1.0; Communication: RS485/Modbus-RTU; Temp Range: 5℃~35℃; Working Pressure: 1.6MPa; Material: CopperOn-demandSetKITOZERCooling capacity consumption monitoring
7Edge Computing GatewayKITOZER-GW-200Interfaces: 4×RS485, 1×Ethernet, 1×LoRa, 1×4G; Protocols: Modbus-RTU/TCP, MQTT, HTTP; Power Supply: DC24V; Operating Temp: -30℃~+75℃; Cache: 64MB; Basic Edge Analysis SupportedOn-demandSetKITOZERMulti-protocol conversion & edge data processing
88-Port Industrial SwitchKITOZER-SW-800Ports: 8×10/100Mbps Ethernet; Transmission Distance: 100m; Power Supply: DC24V; Operating Temp: -30℃~+75℃; Protection Class: IP30; 4-Port POE Supported2SetKITOZERNetwork transmission with POE power supply
9Professional Energy Consumption Monitoring SoftwareKITOZER-EMS-ProFunctions: Data collection, real-time display, historical query, multi-dimensional reports, energy analysis, abnormal alarms, data export; Terminals: PC, Mobile APP; Max Access Points: ≤200; Deployment: Local/Cloud; BA System Docking Supported1SetKITOZERComprehensive energy monitoring & analysis
103KVA UPS Power SupplyKITOZER-UPS-3000Capacity: 3KVA/1800W; Input Voltage: 220V±10%; Output Voltage: 220V±5%; Backup Time: ≥60min; Waveform: Sine Wave; Remote Monitoring Supported1SetKITOZERLong-duration power outage backup with remote management
11Temperature & Humidity SensorKITOZER-TH-100Measurement Range: Temp -40℃~+80℃, Humidity 0%RH~100%RH; Accuracy: Temp ±0.5℃, Humidity ±3%RH; Communication: RS485/Modbus-RTU; Power Supply: DC12V/24V; Protection Class: IP65On-demandSetKITOZEREnvironmental temperature & humidity monitoring
12Current TransformerKITOZER-CT-300Ratio: 300/5A; Accuracy Class: 0.5; Rated Voltage: 0.66kV; Frequency: 50Hz; Operating Temp: -20℃~+60℃; Material: Resin CastingOn-demandSetKITOZERMatched with meters for large current measurement

5.3 High-Tier Configuration List (Intelligent Integration, for Large Smart Parks)

No.Product NameModelTechnical ParametersQtyUnitBrandRemarks
1IoT Single-Phase Smart Electric MeterKITOZER-DDSY862Rated Voltage: 220V; Rated Current: 5(100)A; Accuracy Class: 0.2S; Communication: RS485/LoRa/NB-IoT/Modbus-RTU/TCP; Frequency: 50Hz; Operating Temp: -40℃~+85℃; Full Harmonic, Reactive Power, Demand & Remote Switch Control SupportedOn-demandSetKITOZERHigh-precision IoT monitoring with remote control
2IoT Three-Phase Smart Electric MeterKITOZER-DTSY862Rated Voltage: 3×220/380V; Rated Current: 10(120)A; Accuracy Class: 0.2S; Communication: RS485/LoRa/NB-IoT/4G/Modbus-RTU/TCP; Frequency: 50Hz; Operating Temp: -40℃~+85℃; Full Harmonic, Reactive Power, Time-of-Use Billing, Demand & Branch Remote Cutoff SupportedOn-demandSetKITOZERHigh-precision IoT monitoring with TOU billing & remote control
3Multi-Functional IoT Water MeterKITOZER-LXSY-50Nominal Diameter: DN50; Accuracy Class: 1.0; Communication: LoRa/NB-IoT/4G; Working Pressure: 1.6MPa; Water Temp: 0℃~120℃; Material: 304 Stainless Steel; Anti-Inversion, Tamper, Anti-Freezing & Abnormal Flow Alarm SupportedOn-demandSetKITOZERMulti-function remote transmission with abnormal alarm
4IoT Smart Gas MeterKITOZER-G4Nominal Flow: 4m³/h; Accuracy Class: 0.5; Communication: LoRa/NB-IoT/4G; Working Pressure: 0.5MPa; Operating Temp: -30℃~+70℃; Material: Aluminum Alloy; Tamper, Gas Leak Alarm & Remote Valve Shutoff SupportedOn-demandSetKITOZERRemote monitoring with leak alarm & remote valve control
5High-Precision Heat MeterKITOZER-RLM-50Nominal Diameter: DN50; Accuracy Class: 0.5; Communication: RS485/4G/Modbus-RTU/TCP; Temp Range: 4℃~120℃; Working Pressure: 1.6MPa; Material: 316 Stainless Steel; Bidirectional Measurement SupportedOn-demandSetKITOZERHigh-precision heat monitoring with bidirectional metering
6High-Precision Cooling Capacity MeterKITOZER-CLM-50Nominal Diameter: DN50; Accuracy Class: 0.5; Communication: RS485/4G/Modbus-RTU/TCP; Temp Range: 5℃~45℃; Working Pressure: 1.6MPa; Material: 316 Stainless Steel; Bidirectional Measurement SupportedOn-demandSetKITOZERHigh-precision cooling monitoring with bidirectional metering
7Industrial-Grade Edge Computing GatewayKITOZER-GW-300Interfaces: 8×RS485, 2×Ethernet, 2×LoRa, 1×4G/5G, 1×WiFi; Protocols: Modbus-RTU/TCP, MQTT, HTTP, OPC UA; Power Supply: DC24V; Operating Temp: -40℃~+85℃; Cache: 256MB; AI Algorithm Deployment & Local Control Supported; Protection Class: IP65On-demandSetKITOZERIndustrial multi-protocol conversion & AI edge computing
824-Port Industrial Core SwitchKITOZER-SW-2400Ports: 24×10/100/1000Mbps Ethernet; Transmission Distance: 100m; Power Supply: DC24V/AC220V; Operating Temp: -40℃~+85℃; Protection Class: IP40; 16-Port POE & Dual Power Redundancy Ring Network Supported4SetKITOZERCore network transmission with redundant backup
9Flagship Energy Consumption Monitoring PlatformKITOZER-EMS-UltraFunctions: Data collection, digital twin visualization, AI energy prediction, intelligent optimization, carbon accounting, carbon asset management, multi-dimensional reports, fault early warning, remote control, O&M management, system integration; Terminals: PC, Mobile APP, Large Screen; Max Access Points: ≥500; Deployment: Cloud/Local; Docking with BA, ERP, PV Storage, Charging Piles & Government Supervision Platforms; Customization of Functions & Interfaces Supported1SetKITOZERFull-stack smart park energy management with digital twin & AI
1010KVA UPS Power SupplyKITOZER-UPS-10000Capacity: 10KVA/6000W; Input Voltage: 220V±15%; Output Voltage: 220V±3%; Backup Time: ≥120min; Waveform: Sine Wave; Remote Monitoring & Parallel Redundancy Supported; Protection Class: IP201SetKITOZERIndustrial long-duration backup with redundant parallel function
11Integrated Temp-Humidity-Pressure SensorKITOZER-THP-200Measurement Range: Temp -40℃~+120℃, Humidity 0%RH~100%RH, Pressure 0-1.6MPa; Accuracy: Temp ±0.3℃, Humidity ±2%RH, Pressure ±0.5%FS; Communication: RS485/4G/Modbus-RTU; Power Supply: DC24V; Protection Class: IP67On-demandSetKITOZERIntegrated environmental parameter monitoring
12Harmonic AnalyzerKITOZER-HA-100Monitored Parameters: 2-50 times voltage/current harmonics, THD, power, electric energy; Accuracy: 0.2 Class; Communication: RS485/4G/Modbus-RTU/TCP; Power Supply: DC24V; Operating Temp: -30℃~+75℃On-demandSetKITOZERPower quality harmonic monitoring
1355-inch LCD Video Wall SystemKITOZER-LCD-55Size: 55-inch; Resolution: 1920×1080; Brightness: 500cd/㎡; Contrast Ratio: 4000:1; Bezel Gap: ≤3.5mm; Input Interfaces: HDMI, VGA, DVI; Operating Temp: 0℃~+50℃4SetKITOZERVisual large screen for energy data display
14Data Storage ServerKITOZER-SVR-200CPU: Intel Xeon E3; RAM: 16GB; Storage: 1TB SSD + 4TB HDD; Dual Gigabit Ethernet Ports; Power Supply: AC220V; Operating Temp: -20℃~+60℃; OS: Linux1SetKITOZERPlatform data storage & processing

6. Full Product Technical Parameters

6.1 Electric Energy Meter Series

6.1.1 KITOZER-DD862 (Low-Tier Single-Phase Multi-Function Meter)

  • Rated Voltage: 220V±10%
  • Rated Current: 5(20)A, Max 20A
  • Accuracy Class: Active Power 1.0
  • Communication: RS485, Modbus-RTU Protocol
  • Frequency: 50Hz±0.5Hz
  • Operating Temperature: -20℃~+60℃
  • Power Consumption: ≤1W
  • Protection Class: IP51
  • Display: LCD Liquid Crystal Display

6.1.2 KITOZER-DTSF862 (Mid-Tier High-Precision Three-Phase Multi-Function Meter)

  • Rated Voltage: 3×220/380V±10%
  • Rated Current: 10(80)A, Max 80A
  • Accuracy Class: Active Power 0.5S, Reactive Power 1.0
  • Communication: RS485/LoRa, Modbus-RTU Protocol
  • Frequency: 50Hz±0.5Hz
  • Harmonic Monitoring: Supports 2-31st Harmonics
  • Operating Temperature: -30℃~+70℃
  • Power Consumption: ≤1.5W
  • Protection Class: IP54
  • Display: Backlit LCD Liquid Crystal Display

6.1.3 KITOZER-DTSY862 (High-Tier Three-Phase IoT Smart Meter)

  • Rated Voltage: 3×220/380V±15%
  • Rated Current: 10(120)A, Max 120A
  • Accuracy Class: Active Power 0.2S, Reactive Power 0.5
  • Communication: RS485/LoRa/NB-IoT/4G, Modbus-RTU/TCP Protocol
  • Frequency: 50Hz±0.2Hz
  • Harmonic Monitoring: Supports Full 2-50th Harmonics
  • Functions: Time-of-Use Billing, Demand Statistics, Remote Cutoff, Event Recording
  • Operating Temperature: -40℃~+85℃
  • Power Consumption: ≤2W
  • Protection Class: IP65
  • Display: High-Definition LCD, Remote Wake-Up Supported

6.2 Water Meter Series

6.2.1 KITOZER-LXS-15 (Low-Tier Smart Cold Water Meter)

  • Nominal Diameter: DN15
  • Nominal Flow: 1.5m³/h
  • Accuracy Class: 2.0
  • Communication: Pulse Signal
  • Working Pressure: 1.6MPa
  • Water Temperature: 0℃~40℃
  • Housing Material: Copper
  • Operating Temperature: -20℃~+60℃
  • Protection Class: IP54

6.2.2 KITOZER-LXSY-50 (High-Tier Multi-Functional IoT Water Meter)

  • Nominal Diameter: DN50
  • Nominal Flow: 10m³/h
  • Accuracy Class: 1.0
  • Communication: LoRa/NB-IoT/4G
  • Working Pressure: 1.6MPa
  • Water Temperature: 0℃~120℃
  • Housing Material: 304 Stainless Steel
  • Functions: Anti-Inversion, Tamper-Proof, Anti-Freezing, Abnormal Flow Alarm
  • Operating Temperature: -30℃~+70℃
  • Protection Class: IP67

6.3 Gas Meter Series

6.3.1 KITOZER-G1.6 (Low-Tier Smart Gas Meter)

  • Nominal Flow: 1.6m³/h
  • Accuracy Class: 1.5
  • Communication: Pulse Signal
  • Working Pressure: 0.5MPa
  • Operating Temperature: -10℃~+50℃
  • Housing Material: Aluminum Alloy
  • Protection Class: IP54

6.3.2 KITOZER-G4 (High-Tier IoT Smart Gas Meter)

  • Nominal Flow: 4m³/h
  • Accuracy Class: 0.5
  • Communication: LoRa/NB-IoT/4G
  • Working Pressure: 0.5MPa
  • Operating Temperature: -30℃~+70℃
  • Housing Material: Aluminum Alloy
  • Functions: Tamper Alarm, Gas Leak Alarm, Remote Valve Shutoff
  • Protection Class: IP65

6.4 Heat/Cooling Capacity Meter Series

6.4.1 KITOZER-RLM-25 / CLM-25 (Mid-Tier Heat & Cooling Meters)

  • Nominal Diameter: DN25
  • Accuracy Class: 1.0
  • Communication: RS485, Modbus-RTU Protocol
  • Temperature Range: 4℃~95℃ (Heat Meter) / 5℃~35℃ (Cooling Meter)
  • Working Pressure: 1.6MPa
  • Housing Material: Copper
  • Operating Temperature: -20℃~+60℃
  • Protection Class: IP54

6.4.2 KITOZER-RLM-50 / CLM-50 (High-Tier High-Precision Heat & Cooling Meters)

  • Nominal Diameter: DN50
  • Accuracy Class: 0.5
  • Communication: RS485/4G, Modbus-RTU/TCP Protocol
  • Temperature Range: 4℃~120℃ (Heat Meter) / 5℃~45℃ (Cooling Meter)
  • Working Pressure: 1.6MPa
  • Housing Material: 316 Stainless Steel
  • Functions: Bidirectional Measurement, Cumulative Heat/Cooling Recording, Temperature Difference Monitoring
  • Operating Temperature: -30℃~+70℃
  • Protection Class: IP65

6.5 Collection & Gateway Equipment Series

6.5.1 KITOZER-DC-100 (Low-Tier Data Collector)

  • Communication Interfaces: 2×RS485
  • Supported Protocols: Modbus-RTU, Pulse
  • Power Supply: DC12V±10%
  • Operating Current: ≤100mA
  • Cache: 8MB, Breakpoint Resume Transmission Supported
  • Operating Temperature: -20℃~+60℃
  • Protection Class: IP30

6.5.2 KITOZER-GW-300 (High-Tier Industrial Edge Computing Gateway)

  • Communication Interfaces: 8×RS485, 2×Ethernet, 2×LoRa, 1×4G/5G, 1×WiFi
  • Supported Protocols: Modbus-RTU/TCP, MQTT, HTTP, OPC UA
  • Power Supply: DC24V±20%
  • Operating Current: ≤500mA
  • Cache: 256MB, Local Data Preprocessing & AI Algorithm Deployment Supported
  • Operating Temperature: -40℃~+85℃
  • Protection Class: IP65

6.6 Sensor Series

6.6.1 KITOZER-TH-100 (Mid-Tier Temp & Humidity Sensor)

  • Measurement Range: Temp -40℃~+80℃, Humidity 0%RH~100%RH
  • Accuracy: Temp ±0.5℃, Humidity ±3%RH
  • Communication: RS485, Modbus-RTU Protocol
  • Power Supply: DC12V/24V
  • Operating Temperature: -40℃~+80℃
  • Protection Class: IP65

6.6.2 KITOZER-THP-200 (High-Tier Integrated Temp-Humidity-Pressure Sensor)

  • Measurement Range: Temp -40℃~+120℃, Humidity 0%RH~100%RH, Pressure 0-1.6MPa
  • Accuracy: Temp ±0.3℃, Humidity ±2%RH, Pressure ±0.5%FS
  • Communication: RS485/4G, Modbus-RTU Protocol
  • Power Supply: DC24V
  • Operating Temperature: -40℃~+120℃
  • Protection Class: IP67

6.7 Software Platform Series

6.7.1 KITOZER-EMS-Basic (Low-Tier Basic Monitoring Software)

  • Core Functions: Data collection, real-time data display, historical data query, daily report generation, basic SMS alarms
  • Supported Terminals: Windows PC
  • Max Access Points: ≤50
  • Deployment: Local Windows Server Deployment
  • Data Storage: Local SQLite Database

6.7.2 KITOZER-EMS-Ultra (High-Tier Flagship Energy Management Platform)

  • Core Functions: Data collection, digital twin visualization, AI energy prediction, intelligent optimization scheduling, carbon accounting, carbon asset management, multi-dimensional reports, fault early warning, remote control, O&M work order management, multi-system integration
  • Supported Terminals: PC, iOS/Android Mobile APP, Large Screen
  • Max Access Points: ≥500
  • Deployment: Cloud (Alibaba Cloud/Huawei Cloud) / Local Linux Server Deployment
  • Data Storage: Distributed MySQL + Redis Database
  • Docking Interfaces: Compatible with BA, ERP, PV Energy Storage, Charging Piles & Government Supervision Platforms
  • Customization: Support function, interface & algorithm customization

7. Full Product Application Scope

7.1 Electric Energy Meter Series Application

  • KITOZER-DD862/DT862: Small parks, micro enterprises, shops, residential buildings, basic power metering & statistics.
  • KITOZER-DDSF862/DTSF862: Medium parks, office buildings, commercial complexes, factory workshops, high-precision power monitoring, harmonic analysis & reactive power compensation evaluation.
  • KITOZER-DDSY862/DTSY862: Large smart parks, industrial parks, data centers, hospitals, universities, remote IoT monitoring, TOU billing, demand management, remote control & carbon accounting data collection.

7.2 Water Meter Series Application

  • KITOZER-LXS-15: Small parks, shops, residences, basic tap water measurement.
  • KITOZER-LXSY-20: Medium parks, office buildings, factories, remote cold/hot water monitoring, preliminary water leakage detection.
  • KITOZER-LXSY-50: Large industrial parks, municipal water supply, reclaimed water, green irrigation, sewage discharge, precise leakage detection, water quota management & water resource optimization.

7.3 Gas Meter Series Application

  • KITOZER-G1.6: Small park canteens, shops, household small gas equipment, basic gas consumption measurement.
  • KITOZER-G2.5: Medium park canteens, boiler rooms, small production workshops, remote gas monitoring & preliminary leak alarm.
  • KITOZER-G4: Large park boiler rooms, large canteens, industrial production workshops, gas heating systems, precise leak alarm, remote valve shutoff & gas safety control.

7.4 Heat/Cooling Capacity Meter Series Application

  • KITOZER-RLM-25/CLM-25: Medium park buildings, office buildings, small heat exchange stations, central heating & central air conditioning cooling monitoring, basic energy efficiency analysis.
  • KITOZER-RLM-50/CLM-50: Large industrial parks, commercial complexes, large heat exchange stations, district heating & cooling systems, high-precision bidirectional metering, precise energy efficiency analysis & air conditioning optimization.

7.5 Collection & Gateway Equipment Application

  • KITOZER-DC-100: Small parks, simple buildings, basic meter data collection, protocol conversion & local data caching.
  • KITOZER-GW-200: Medium multi-building parks, multi-protocol data collection, edge preliminary analysis, stable data upload & basic equipment linkage.
  • KITOZER-GW-300: Large smart/zero-carbon industrial parks, data centers, multi-protocol compatibility, AI edge computing, local pre-control, equipment linkage & cross-system integration.

7.6 Sensor Series Application

  • KITOZER-TH-100: Park power distribution rooms, equipment rooms, building corridors, warehouses, environmental monitoring to optimize air conditioning & ventilation.
  • KITOZER-THP-200: Heat exchange stations, pump rooms, pipe network nodes, industrial workshops, integrated parameter monitoring to guarantee pipeline safety & energy transmission efficiency.

7.7 Software Platform Application

  • KITOZER-EMS-Basic: Small parks, micro enterprises, basic energy data monitoring, query & simple report generation for fundamental energy management.
  • KITOZER-EMS-Pro: Medium parks, office buildings, commercial complexes, comprehensive energy monitoring, multi-dimensional analysis, abnormal alarms & data export for refined energy management.
  • KITOZER-EMS-Ultra: Large smart/zero-carbon industrial parks, digital twin visualization, AI intelligent optimization, carbon accounting & full customized integrated management for low-carbon smart transformation.

7.8 Supporting Equipment (Switches, UPS, Large Screen) Application

  • Industrial Switches: Power distribution rooms, equipment rooms, weak current rooms, stable network transmission & equipment interconnection.
  • UPS Power Supply: Data centers, monitoring rooms, uninterrupted power supply & voltage stabilization for continuous system operation.
  • Large Screen Display System: Park monitoring & management halls, real-time visual display of energy data, equipment status & alarm information for intuitive management.

8. Full Product Advantages

8.1 Core Advantages of Full Product Line

8.1.1 Customization Capability

  • Hardware Customization: Customize meter range, accuracy, communication mode & appearance according to park scale, monitoring points & energy types; support high/low temperature, humid & explosion-proof customization for industrial, municipal & commercial scenarios.
  • Software Customization: Customize platform modules, interface layout, report formats, alarm rules & integration interfaces; support brand LOGO embedding & exclusive domain name configuration.
  • Solution Customization: One-on-one technical service, on-site survey to design exclusive monitoring schemes compatible with existing park equipment, network architecture & management processes, reducing renovation costs & difficulties.

8.1.2 OEM & ODM Manufacturing Capacity

Two modern production bases with automated production lines, full-process OEM/ODM service for metering instruments, collectors, gateways & sensors; support private labeling, customized model & parameter settings. Strict ISO9001 & ISO14001 quality control to ensure stable product consistency and compliance with national standards.

8.1.3 Confidentiality Mechanism

Sign non-disclosure agreements to fully protect customer technical schemes, project data, customized parameters & commercial information; independent R&D of core technology without third-party dependence; software platform adopts data encryption & hierarchical authority management to prevent data leakage.

8.1.4 In-Stock Supply Capacity

Core products maintained in inventory across multiple national warehouses for fast delivery, shorten construction cycles and support urgent project expedited shipment, reducing logistics costs.

8.1.5 Full-Link Product Coverage

Complete product portfolio covering electricity, water, gas, heat & cooling monitoring from perception layer, transmission layer to application platform. One-stop procurement eliminates multi-brand compatibility risks and reduces integration costs.

8.2 Functional Features of Each Product Series

8.2.1 Electric Energy Meter Series

  • High Precision: 1.0 Class (low-tier), 0.5S Class (mid-tier), 0.2S Class (high-tier), meeting commercial settlement, energy statistics & high-precision carbon accounting requirements.
  • Multi-Communication Compatibility: RS485, LoRa, NB-IoT, 4G/5G, WiFi for wired, wireless & IoT networking scenarios.
  • Integrated Multi-Functions: High-tier models support harmonic monitoring, reactive power metering, TOU billing, demand statistics & remote switch control without additional auxiliary equipment.
  • High Stability: Wide voltage & wide temperature design with strong anti-interference performance for complex electromagnetic environments in parks, long-term stable operation.

8.2.2 Water/Gas Meter Series

  • Leakage & Loss Prevention: Water meters support anti-inversion, anti-freezing & abnormal flow alarms; gas meters support tamper, leak alarms & remote valve shutoff to cut energy waste and ensure safety.
  • Remote Data Transmission: Mid & high tiers support wireless remote transmission, eliminating manual meter reading and cutting labor costs while improving data timeliness.
  • Corrosion-Resistant Materials: Copper, stainless steel & aluminum alloy housings with long service life, resistant to water/gas medium corrosion.

8.2.3 Collection & Gateway Equipment Series

  • Multi-Protocol Compatibility: Support Modbus-RTU/TCP, MQTT, HTTP, OPC UA to connect all mainstream third-party meters & sensors with strong compatibility.
  • Edge Computing: High-tier gateways deploy AI algorithms, local data preprocessing & on-site control to reduce cloud dependence, lower network latency and improve system response speed.
  • Industrial High Protection: IP65 protection rating for outdoor, dusty & humid harsh environments.

8.2.4 Software Platform Series

  • Digital Twin Visualization: High-tier platform builds 3D park twin models linked with real-time energy data for intuitive energy distribution & equipment status display.
  • AI Intelligent Analysis: Built-in AI algorithms for energy trend prediction, load diagnosis, energy efficiency optimization suggestions & automatic carbon accounting to realize data-driven decision-making and energy conservation.
  • Multi-System Integration: Seamless docking with BA, ERP, PV storage & charging pile systems to break data silos and achieve integrated unified management.
  • Multi-Terminal Adaptation: PC, mobile APP & large screen support for anytime remote data viewing, alarm reception & equipment control.

8.3 Technical Parameter Advantages

  • Ultra-High Precision: Core metering products reach 0.2S Class (electric meters) & 0.5 Class (water/gas/heat/cooling meters), exceeding national industry standards for carbon accounting high-precision demands.
  • Wide Measurement Range: Broad meter ranges adapt to low/high voltage & small/large flow scenarios, supporting park capacity expansion without equipment replacement.
  • Ultra-Wide Operating Temperature: -40℃~+85℃ stable operation for extreme cold northern regions and hot southern climates.
  • Low Power Consumption: Electric meters ≤2W, collectors ≤100mA, gateways ≤500mA, reducing self-energy consumption of the whole system for green operation.

9. Tender Control Parameters (★ Marked Core Parameters)

9.1 Electric Energy Meter Series Tender Control Parameters

9.1.1 KITOZER-DD862/DT862 (Low-Tier)

★ Rated Voltage: 220V / 3×220/380V±10% ★ Accuracy Class: Active Power 1.0 ★ Communication: RS485, Modbus-RTU Protocol ★ Operating Temperature: -20℃~+60℃ ★ Protection Class: IP51

9.1.2 KITOZER-DDSF862/DTSF862 (Mid-Tier)

★ Rated Voltage: 220V / 3×220/380V±10% ★ Accuracy Class: Active Power 0.5S, Reactive Power 1.0 ★ Communication: RS485/LoRa, Modbus-RTU Protocol ★ Harmonic Monitoring: Support 2-31st Harmonics ★ Operating Temperature: -30℃~+70℃ ★ Protection Class: IP54

9.1.3 KITOZER-DDSY862/DTSY862 (High-Tier)

★ Rated Voltage: 220V / 3×220/380V±15% ★ Accuracy Class: Active Power 0.2S, Reactive Power 0.5 ★ Communication: RS485/LoRa/NB-IoT/4G, Modbus-RTU/TCP Protocol ★ Harmonic Monitoring: Support Full 2-50th Harmonics ★ Functions: TOU Billing, Demand Statistics, Remote Cutoff, Event Recording ★ Operating Temperature: -40℃~+85℃ ★ Protection Class: IP65

9.2 Water Meter Series Tender Control Parameters

9.2.1 KITOZER-LXS-15 (Low-Tier)

★ Nominal Diameter: DN15 ★ Accuracy Class: 2.0 ★ Communication: Pulse Signal ★ Working Pressure: 1.6MPa ★ Water Temperature: 0℃~40℃

9.2.2 KITOZER-LXSY-50 (High-Tier)

★ Nominal Diameter: DN50 ★ Accuracy Class: 1.0 ★ Communication: LoRa/NB-IoT/4G ★ Working Pressure: 1.6MPa ★ Water Temperature: 0℃~120℃ ★ Functions: Anti-Inversion, Tamper-Proof, Anti-Freezing, Abnormal Flow Alarm

9.3 Gas Meter Series Tender Control Parameters

9.3.1 KITOZER-G1.6 (Low-Tier)

★ Nominal Flow: 1.6m³/h ★ Accuracy Class: 1.5 ★ Communication: Pulse Signal ★ Working Pressure: 0.5MPa

9.3.2 KITOZER-G4 (High-Tier)

★ Nominal Flow: 4m³/h ★ Accuracy Class: 0.5 ★ Communication: LoRa/NB-IoT/4G ★ Working Pressure: 0.5MPa ★ Functions: Tamper Alarm, Gas Leak Alarm, Remote Valve Shutoff

9.4 Heat/Cooling Capacity Meter Series Tender Control Parameters

9.4.1 KITOZER-RLM-25/CLM-25 (Mid-Tier)

★ Nominal Diameter: DN25 ★ Accuracy Class: 1.0 ★ Communication: RS485, Modbus-RTU Protocol ★ Temperature Range: 4℃~95℃ (Heat Meter) / 5℃~35℃ (Cooling Meter)

9.4.2 KITOZER-RLM-50/CLM-50 (High-Tier)

★ Nominal Diameter: DN50 ★ Accuracy Class: 0.5 ★ Communication: RS485/4G, Modbus-RTU/TCP Protocol ★ Temperature Range: 4℃~120℃ (Heat Meter) / 5℃~45℃ (Cooling Meter) ★ Functions: Bidirectional Measurement, Cumulative Heat/Cooling Recording

9.5 Collection & Gateway Tender Control Parameters

9.5.1 KITOZER-DC-100 (Low-Tier)

★ Communication Interfaces: 2×RS485 ★ Supported Protocols: Modbus-RTU, Pulse ★ Power Supply: DC12V±10% ★ Cache: 8MB, Breakpoint Resume Transmission Supported

9.5.2 KITOZER-GW-300 (High-Tier)

★ Communication Interfaces: 8×RS485, 2×Ethernet, 2×LoRa, 1×4G/5G, 1×WiFi ★ Supported Protocols: Modbus-RTU/TCP, MQTT, HTTP, OPC UA ★ Power Supply: DC24V±20% ★ Cache: 256MB, AI Algorithm Deployment Supported ★ Protection Class: IP65

9.6 Software Platform Tender Control Parameters

9.6.1 KITOZER-EMS-Ultra (High-Tier)

★ Core Functions: Digital Twin Visualization, AI Energy Prediction, Carbon Accounting, Multi-System Integration ★ Supported Terminals: PC, iOS/Android Mobile APP, Large Screen ★ Max Access Points: ≥500 ★ Deployment: Cloud / Local On-Premise ★ Docking Interfaces: Compatible with BA, ERP, PV Storage, Charging Piles & Government Supervision Platforms

10. Full Product Solutions

10.1 Small Park Energy Consumption Monitoring Solution (Low-Tier)

10.1.1 Project Background

Small parks (Area ≤50,000㎡, Buildings ≤5), dominated by micro enterprises & shops, mainly consuming electricity and tap water with limited gas/heat usage. Demands include basic metering, eliminating manual meter reading and grasping overall energy consumption data.

10.1.2 Solution Composition

  • Perception Layer: Deploy KITOZER-DD862/DT862 electric meters, LXS-15 water meters & G1.6 gas meters to cover main power distribution, building power distribution, public water & gas points.
  • Transmission Layer: RS485 bus networking with KITOZER-DC-100 data collectors & SW-500 industrial switches for data acquisition & transmission.
  • Platform Application Layer: KITOZER-EMS-Basic basic monitoring software & UPS-1000 UPS for real-time data display, historical query, simple reports & basic alarms.

10.1.3 Solution Value

  • Low initial investment to meet basic monitoring needs, cutting manual meter reading labor costs by over 80%.
  • Real-time overall & building-level energy consumption tracking to identify obvious waste points, achieving preliminary energy savings of 5%-10%.
  • Automatic data recording for historical traceability, providing basic data support for subsequent energy-saving renovations.

10.2 Medium Park Energy Consumption Monitoring Solution (Mid-Tier)

10.2.1 Project Background

Medium parks (Area 50,000-200,000㎡, Buildings 5-20), including office buildings, commercial complexes & small factories, consuming electricity, water, gas, heat and cooling capacity. Demands include full energy monitoring, multi-dimensional analysis, abnormal alarms & energy efficiency evaluation for refined management.

10.2.2 Solution Composition

  • Perception Layer: Deploy DDSF862/DTSF862 high-precision meters, LXSY-20 remote water meters, G2.5 remote gas meters, RLM-25/CLM-25 heat/cooling meters, TH-100 temp-humidity sensors & CT-300 current transformers covering main power distribution, building power distribution, workshops, public areas, heat exchange stations & pipe network nodes.
  • Transmission Layer: Hybrid RS485+LoRa networking with KITOZER-GW-200 edge gateways & SW-800 POE industrial switches for multi-protocol conversion & preliminary edge analysis.
  • Platform Application Layer: KITOZER-EMS-Pro professional monitoring software & UPS-3000 UPS for real-time display, multi-dimensional reports, energy analysis, abnormal alarms, data export & BA system docking.

10.2.3 Solution Value

  • Full coverage of all energy types, realizing refined three-level monitoring (park/building/equipment) with energy savings of 10%-20%.
  • Real-time alarms for abnormal energy consumption & equipment faults to accelerate troubleshooting, cutting operation & maintenance costs by over 20%.
  • Automatic generation of energy & efficiency reports to meet government supervision & enterprise management requirements, supporting green park construction.

10.3 Large Smart/Zero-Carbon Park Energy Consumption Monitoring Solution (High-Tier)

10.3.1 Project Background

Large parks (Area ≥200,000㎡, Buildings ≥20), industrial parks, data centers & zero-carbon commercial complexes with large-scale complex energy consumption including distributed PV, energy storage & charging piles. Demands cover intelligent energy management, digital twin visualization, AI optimization, carbon accounting & cross-system integration to achieve carbon peaking & neutrality goals.

10.3.2 Solution Composition

  • Perception Layer: Deploy DDSY862/DTSY862 IoT electric meters, LXSY-50 multi-functional water meters, G4 IoT gas meters, RLM-50/CLM-50 high-precision heat/cooling meters, THP-200 integrated temp-humidity-pressure sensors & HA-100 harmonic analyzers for full-point full-energy monitoring.
  • Transmission Layer: Hybrid RS485+LoRa+4G/5G networking with KITOZER-GW-300 industrial edge gateways & SW-2400 core redundant switches for multi-protocol compatibility, AI edge computing & redundant stable transmission.
  • Platform Application Layer: KITOZER-EMS-Ultra flagship energy management platform, SVR-200 data server, UPS-10000 industrial UPS & 55-inch video wall system for digital twin visualization, AI load prediction, intelligent dispatching, carbon asset management, remote equipment control, O&M workflow management & cross-system integration (PV, storage, charging piles, BA, ERP, government supervision platforms).

10.3.3 Solution Value

  • Build an integrated “Source-Grid-Load-Storage” energy control system with full-link precise monitoring & intelligent scheduling, reducing comprehensive park energy consumption by 20%-30%.
  • Digital twin + AI analysis to pre-alert energy waste, equipment faults & safety hazards, lifting management efficiency by over 50%.
  • Automatic carbon accounting & ESG reports to support carbon trading & green finance, accelerating zero-carbon park certification with annual carbon emission reduction up to 12,000 tons in typical projects.
  • Eliminate data silos via full cross-system integration to realize unified intelligent park operation.

11. Product Application Cases

11.1 Small Industrial Park Project in Guangzhou (Low-Tier Scheme)

11.1.1 Project Overview

Park area: 30,000㎡, 4 buildings housing 20 light manufacturing & office micro enterprises. Original manual meter reading led to low efficiency & large data errors without clear energy consumption distribution data.

11.1.2 Implementation Scope

Adopt KITOZER low-tier solution: 50 single-phase meters, 10 three-phase meters, 30 smart water meters, 5 gas meters, 5 data collectors, 2 industrial switches & 1 set of basic EMS software.

11.1.3 Project Outcomes

  • Automatic remote data collection cut manual reading costs by 90% with data accuracy above 99.5%.
  • Identified waste from public lighting & standby workshop equipment; optimization reduced monthly power consumption by 12,000 kWh with 12% energy saving rate.
  • Complete energy data archive established to support subsequent energy-saving renovation & equipment upgrade decision-making.

11.2 Medium Office Park Project in Shenzhen (Mid-Tier Scheme)

11.2.1 Project Overview

Park area: 120,000㎡, 8 office buildings with 300 settled enterprises. Main energy loads: air conditioning, lighting, office equipment, tap water, heating & cooling capacity, requiring full energy monitoring & efficiency analysis.

11.2.2 Implementation Scope

Adopt KITOZER mid-tier solution: 200 high-precision electric meters, 150 remote water meters, 20 remote gas meters, 30 heat meters, 30 cooling meters, 80 temp-humidity sensors, 15 edge gateways, 8 industrial switches & 1 set of professional EMS software.

11.2.3 Project Outcomes

  • Four-level refined monitoring (park/building/floor/equipment) covering all energy types (electricity, water, gas, heat, cooling).
  • System analyzed air conditioning efficiency, identifying unreasonable temperature settings & low-efficiency operation; optimization saved monthly electricity & heat costs of 800,000 RMB with 18% energy saving rate.
  • Real-time abnormal alarms accelerated pipeline leakage & equipment fault troubleshooting, lifting O&M efficiency by 25% and cutting O&M costs by 22%.

11.3 Large Zero-Carbon Industrial Park Project in Suzhou (High-Tier Scheme)

11.3.1 Project Overview

Park area: 500,000㎡, 25 buildings for high-end manufacturing & new energy enterprises, equipped with rooftop PV, energy storage stations & charging piles. Complex energy structure with zero-carbon park construction target, requiring intelligent energy management, carbon accounting & cross-system integration.

11.3.2 Implementation Scope

Adopt KITOZER high-tier flagship solution: 500 IoT electric meters, 300 multi-functional water meters, 50 IoT gas meters, 80 high-precision heat meters, 80 high-precision cooling meters, 200 integrated THP sensors, 30 harmonic analyzers, 50 industrial edge gateways, 20 core switches, 1 flagship EMS platform, 2 data servers, 2 industrial UPS & 4 sets of 55-inch video wall systems.

11.3.3 Project Outcomes

  • Digital twin energy management platform realizes full real-time monitoring of PV, energy storage, grid & load, supporting coordinated optimization of “Source-Grid-Load-Storage”.
  • AI algorithms optimize PV consumption, energy storage charge-discharge & peak-shifting power strategies, cutting comprehensive park energy consumption by 28% and lifting green power consumption rate to 85%.
  • Automatic carbon footprint & carbon accounting reports generated, achieving annual carbon emission reduction of 12,000 tons and passing preliminary zero-carbon park certification.
  • Full integration of PV, energy storage, charging piles, BA & ERP systems enables data sharing & linkage control, significantly upgrading park intelligent operation level.

12. Product Fault Troubleshooting & Maintenance

12.1 Meters (Electric/Water/Gas/Heat/Cooling Meters)

12.1.1 Common Faults & Troubleshooting

  1. Black Screen / No Data Display Fault Cause: Abnormal power supply, damaged power module, meter failure Troubleshooting: Check power voltage within rated range & loose wiring; replace power module; replace meter if fault persists.
  2. No Data Upload / Communication Failure Fault Cause: Loose/damaged communication cable, incorrect communication parameters, damaged meter communication module, gateway fault Troubleshooting: Inspect RS485/LoRa/4G wiring integrity; match meter address, baud rate & protocol with gateway; replace communication module; verify gateway operation status.
  3. Large Measurement Error / Inaccurate Metering Fault Cause: Meter accuracy drift, non-standard installation, damaged sensor, external electromagnetic interference Troubleshooting: Calibrate meters annually; install meters per specifications (avoid strong magnetic interference for electric meters, horizontal installation for water meters); replace damaged sensors; eliminate external interference from high-power equipment.
  4. Gas Meter Leak Alarm Triggered Fault Cause: Actual gas leakage, damaged sensor, short-circuited wiring Troubleshooting: Close gas valve immediately to inspect leakage points; if no leakage exists, replace damaged sensor or repair short-circuited wiring.

12.1.2 Maintenance Schedule

  • Monthly Inspection: Check meter appearance integrity, corrosion, display status, communication stability & water/gas leakage risks.
  • Periodic Calibration: Electric/heat/cooling meters calibrated once per year; water/gas meters calibrated once every two years to maintain national standard metering accuracy.
  • Quarterly Cleaning: Remove surface dust & oil stains to avoid internal component damage; outdoor meters equipped with waterproof, sun-proof & anti-freezing protection covers.
  • Wireless Meter Battery Replacement: LoRa/NB-IoT built-in batteries last 3-5 years; inspect battery voltage regularly and replace low-voltage batteries to prevent data loss.

12.2 Collection & Gateway Equipment

12.2.1 Common Faults & Troubleshooting

  1. Offline / Network Disconnection Fault Cause: Abnormal power supply, loose/damaged network cable, incorrect network parameters, equipment failure, loose wireless antenna Troubleshooting: Verify power supply; recheck cable connection; match IP, subnet mask & gateway parameters; tighten antenna & check signal strength; replace faulty equipment.
  2. Incomplete Data Collection / Packet Loss Fault Cause: Excessively long communication cables, strong interference, protocol mismatch, insufficient cache, overloaded gateway Troubleshooting: Shorten cable length & add shielding layers away from interference sources; unify equipment communication protocols; clear device cache; optimize gateway configuration to reduce load.
  3. Edge Calculation Failure / Control Invalidation Fault Cause: Algorithm program error, wrong parameter configuration, hardware damage Troubleshooting: Restart gateway; verify algorithm program & parameter settings; redeploy algorithms; replace equipment if fault persists.

12.2.2 Maintenance Schedule

  • Monthly Inspection: Check equipment appearance, indicator light status, cable/antenna tightness & overheating risks.
  • Quarterly Software Upgrade: Update firmware to fix vulnerabilities & optimize performance; back up configuration parameters regularly to avoid data loss.
  • Heat Dissipation & Dust Removal: Clean heat sinks & fans quarterly to guarantee ventilation; install equipment in dry & ventilated locations, avoid high humidity & high temperature environments.

12.3 Software Platform

12.3.1 Common Faults & Troubleshooting

  1. Failed Login / Platform Inaccessibility Fault Cause: Server power failure, network interruption, suspended software service, insufficient user permissions Troubleshooting: Check server operation & network connectivity; restart software background services; verify account password & permission allocation.
  2. Abnormal / Missing Display Data Fault Cause: Offline collection terminals, broken data transmission, database failure, program error Troubleshooting: Confirm collector online status & communication; restart data transmission service; repair abnormal database; reboot & update platform software.
  3. Missing Alarm Push / False Alarms Fault Cause: Incorrect alarm threshold rules, wrong push channel settings, damaged sensors, abnormal dirty data Troubleshooting: Adjust alarm threshold & classification rules; verify SMS/APP push configuration; replace faulty sensors; clear abnormal historical data.

12.3.2 Maintenance Schedule

  • Server Monthly Inspection: Monitor CPU, memory & disk usage; quarterly clean junk files & optimize system performance; daily automatic database backup + weekly manual backup to prevent data loss.
  • Quarterly Platform Upgrade: Roll out new versions with functional upgrades, vulnerability fixes & performance optimization; audit system logs regularly to identify hidden faults; optimize platform configuration to accelerate loading speed.
  • Authority Management: Timely delete resigned staff accounts; enforce complex password policies with periodic password updates to guarantee system data security.

12.4 Supporting Equipment (Switches, UPS, Large Screen)

12.4.1 Common Faults & Troubleshooting

  1. Disconnected Switch Port / Abnormal Flashing Indicators Fault Cause: Loose/damaged network cable, damaged port, network loopback Troubleshooting: Replace network cable; switch to spare port; locate & eliminate network loopback faults.
  2. UPS Power Failure / Alarm Triggered Fault Cause: Aging battery, abnormal input voltage, faulty inverter Troubleshooting: Inspect input voltage range; replace aging batteries; repair internal inverter components.
  3. Black Screen / Blurred Video Wall Display Fault Cause: Loose signal cable, damaged screen panel, faulty controller Troubleshooting: Reconnect signal cables; restart display controller; repair defective screen modules.

12.4.2 Maintenance Schedule

  • Industrial Switches: Monthly port & heat dissipation inspection; quarterly dust cleaning; regular firmware upgrade.
  • UPS Power Supply: Monthly battery voltage & operation inspection; quarterly full discharge maintenance; battery replacement every 3-5 years.
  • Large Video Wall: Monthly screen surface cleaning; regular cable connection inspection; avoid long-term maximum brightness to extend service life.

13. Factory Strength & After-Sales Service

13.1 Factory Strength

13.1.1 Production Scale

KITOZER owns two modern production bases (Guangzhou & Suzhou) covering total land area of 50,000㎡ with 30,000㎡ construction area, equipped with 12 automated production lines, 50 precision processing equipment & 30 professional testing devices. Annual production capacity reaches 1 million metering instruments, 200,000 collectors/gateways & 100,000 sets of software platforms to support bulk procurement for large-scale park projects.

13.1.2 R&D Capability

100-person professional R&D team including 10 PhDs & 30 Masters, focusing on energy monitoring, IoT, big data & AI algorithm R&D. Annual R&D investment accounts for 15% of total revenue, with 50 independent intellectual property patents & 30 software copyrights; all core technologies are self-developed with continuous iterative product upgrades.

13.1.3 Quality Control System

Fully compliant with ISO9001 Quality Management System, ISO14001 Environmental Management System & ISO45001 Occupational Health & Safety Management System. Full-process quality control from raw material procurement, production processing, finished product testing to factory delivery. Core chips sourced from Texas Instruments, communication modules from Quectel. Every product undergoes 72-hour aging test, precision calibration & communication testing before shipment with factory pass rate above 99.9%.

13.1.4 Production Qualifications

National Measuring Instrument Manufacturing License, Explosion-Proof Certification, CE, FCC & full ISO system certifications. All products comply with national & industrial standards including Multi-Function Electric Energy Meters, Smart Water Meters & Technical Specifications for Energy Consumption Monitoring Systems, supporting domestic & overseas project delivery.

13.2 After-Sales Service System

13.2.1 Service Network

National integrated after-sales network with 5 regional service centers (South China, East China, North China, Southwest, Northwest) & 20 local offices, 200 professional technical engineers providing 7×24-hour all-weather support. Service response time ≤2 hours; on-site service arrival within 24 hours nationwide.

13.2.2 Full Lifecycle Service Content

  1. Pre-Sales Service Free on-site survey, customized scheme design, technical consultation & product selection; one-on-one dedicated technical docking for exclusive energy monitoring solutions.
  2. In-Sales Service Free professional training covering equipment installation, commissioning, operation & maintenance; full project progress tracking with on-site technical guidance to guarantee smooth project delivery.
  3. After-Sales Service
  • Warranty Policy: All hardware products enjoy 3-year full warranty; software platform lifelong free maintenance. Free repair, component replacement & whole machine swap for quality defects within warranty period.
  • Out-of-Warranty Repair: Lifelong paid maintenance service after warranty expiration, only charging component cost without labor fees; priority emergency repair channel for urgent faults.
  • Upgrade Service: Lifelong free software version upgrades with new functional modules, vulnerability patches & performance optimization; hardware upgrade & trade-in schemes available.
  • Optional Annual O&M Service: Regular on-site inspection, equipment calibration, dust cleaning, fault troubleshooting, automatic data backup & system performance optimization to guarantee long-term stable system operation.
  • Technical Support: 7×24-hour phone, WeChat & online customer service; remote desktop fault diagnosis; periodic online technical training & seminars to improve customer internal O&M capabilities.

13.2.3 Service Commitment

  • Quality Commitment: All products fully comply with national & industrial standards with qualified metering accuracy & stable long-term operation.
  • Response Commitment: 7×24-hour full-time technical support, fault response within 2 hours, on-site service within 24 hours nationwide.
  • Warranty Commitment: 3-year full hardware warranty, lifelong free software maintenance, free repair & replacement within warranty period.
  • Satisfaction Commitment: Customer-centric professional, efficient & thoughtful service to achieve 100% customer satisfaction.

14. Conclusion

The park energy consumption monitoring integrated system serves as core infrastructure for park digital transformation, green low-carbon operation and carbon peaking & neutrality target implementation. Through real-time monitoring, intelligent analysis and linkage control of full energy types (electricity, water, gas, heat, cooling capacity), it realizes refined, intelligent and low-carbon park energy management.

With robust manufacturing capacity, advanced independent R&D, strict quality control and comprehensive after-sales service, KITOZER provides a full range of energy monitoring equipment covering perception layer, transmission layer and application platform, delivering customized exclusive solutions for small, medium and large parks to meet diversified energy management demands of various scenarios.

Moving forward, KITOZER will continue deepening R&D in energy monitoring, IoT and AI technologies, continuously optimize product performance and upgrade service quality, assisting more parks to achieve energy conservation, carbon reduction, efficiency improvement and green low-carbon transformation, contributing to China’s dual carbon goals and high-quality development of the energy industry.

15 Search Keywords, SEO & Tag System (Directly Copy for Backend Use)

15.1 Core Keyword Library

15.1.1 Main Core Keywords

Park energy consumption monitoring integration, park energy consumption monitoring system, smart park energy management, park energy monitoring platform, online park energy consumption monitoring

15.1.2 High-Conversion Long-Tail Keywords

Industrial park energy consumption monitoring solution, integrated park electricity-water-gas-heat-cooling monitoring, smart park energy monitoring system manufacturer, customized park energy monitoring platform, park energy monitoring system installation & commissioning, zero-carbon park energy consumption management system, KITOZER park energy monitoring equipment, park energy monitoring system quotation & scheme

15.1.3 Industry Traffic Keywords

Smart park construction, integrated park intelligence, industrial energy management, energy control system, dual-carbon park solution, building energy consumption monitoring, online energy consumption monitoring for key energy users, park energy-saving & carbon reduction renovation

15.1.4 Brand Exclusive Keywords

LAIAN Intelligence, Guangzhou Laian Intelligent, KITOZER energy consumption monitoring, Laian park energy system, Laian intelligent energy integration

15.1.5 Drop-Down & Related Search Keywords

Which manufacturer supplies reliable park energy monitoring systems, composition of park energy monitoring system, schematic diagram of park energy monitoring system, configuration list of park energy monitoring system, technical parameters of park energy monitoring system, application cases of park energy monitoring system

15.2 SEO Optimization Tag System

15.2.1 Title Tag

Park Energy Consumption Monitoring Integrated System | Smart Park Energy Management Platform | Guangzhou Laian Intelligent KITOZER

Scroll to Top