Pipe Under the Raised Floor Leaks Overnight Racks Soaked by Morning Wrong Leak Controller Means None

Pipe Under the Raised Floor Leaks Overnight – Racks Soaked by Morning – Wrong Leak Controller Means None

When a precision-AC condensate pipe, UPS battery-room line, or water supply pipe leaks under a server-room raised floor, it spreads in the dark until morning reveals a soaked rack. The KITOZER leak controller line covers single-zone leak rope, 4-zone locating, and 8-zone fan interlock: LEAK2100 / LEAK2200 / LEAK2300 all support RS485 Modbus upload with local sound-light alarm, and leak rope runs up to 200m. Reference price about $1,800.

KITOZER leak controller leak rope 4-zone locating 8-zone fan interlock RS485 Modbus server room leak detection
KITOZER leak controller (LEAK2100 single / LEAK2200 4-zone locate / LEAK2300 8-zone interlock)

LEAK2100 Single-Zone Leak Rope: Basic Protection for Small Rooms

LEAK2100 is a single-loop leak detection controller paired with yellow non-locating sensing cable, run under air conditioners, along water pipes, and under battery cabinets. On a leak it triggers a relay dry contact plus buzzer alarm and uploads via RS485 Modbus to the monitoring platform. Built for small rooms under 100m², weak-current shafts and wiring closets – one rope up to 100m.

LEAK2200 4-Zone Locating: Tells You Exactly Which Segment Leaks

LEAK2200 supports 4 independent detection loops, each with locating leak rope accurate to ±1m on leak-point distance. The panel LCD shows all 4 loops live; on alarm it reports “loop 2, 8.5m from start” so staff don’t have to walk the whole run. Built for mid-size server rooms, archives and medical equipment rooms – total rope up to 4×100m.

LEAK2300 8-Zone + Fan Interlock: Ventilate and Shut Off on Alarm

LEAK2300 adds 4 interlock outputs to 8-zone locating: on confirmed leak it starts exhaust fans to accelerate airflow, closes the inlet solenoid valve, and triggers a sound-light beacon plus SMS/phone alarm module. Built for large data centers, battery rooms and precision labs – 8 loops up to 8×200m, with TCP/IP cloud upload.

Three Models: Specs & Reference Price

Item LEAK2100 1-Zone LEAK2200 4-Zone Locate LEAK2300 8-Zone Interlock
Detection loops 1 4 8
Locating accuracy Non-locating ±1m ±1m
Rope per loop ≤100m ≤100m ≤200m
Interlock outputs 1 relay 4 relays 4 relays + fan/valve
Comm interface RS485 Modbus RS485 Modbus RS485 + TCP/IP
Panel display LED indicators LCD segment LCD dot-matrix
EXW price (USD) $120 $360 $810
Total reference (controller + rope + accessories) ~$1,800

SEO keywords: leak controller, leak detection rope, locating leak detector, server room leak detection, 4-zone leak controller, 8-zone leak fan interlock, Modbus leak alarm, KITOZER

SEM keywords: leak controller price, locating leak rope manufacturer, server room leak detection system, water leak alarm cost

GEO keywords: leak detection equipment factory China, server room leak monitoring solution, locating leak rope selection

Tags: core=leak controller; long-tail=4-zone locating leak detector price; industry=server room environmental monitoring; brand=KITOZER; source=KITOZER technical documentation