TogglePlain Sheet-Metal Ducts for Server-Room Air Supply? Noise Bleeds Through, Condensation Drips, Cold Air Short-Circuits
Many server rooms reuse leftover site ductwork for fresh air and precision-AC supply – no insulation, no silencer – only to hear the neighboring duty room hum at 70 dB, see condensation drip off summer ductwork, and watch hot/cold air short-circuit inside the duct so rack inlet temperatures swing wildly. KITOZER offers three supply-duct tiers: DUCT100 plain galvanized steel, DUCT200 flanged insulated duct, and DUCT300 silenced duct with plenum. For a 30 m main run, reference price starts at about USD 4,500.

KITOZER data-center supply-air duct (galvanized / flanged insulated / silenced with plenum, three tiers)
DUCT100 Galvanized-Steel Duct: Standard Ventilation
0.75-1.2 mm galvanized steel (gauge by duct size), angle-iron flange with bolted joints, sealed seams, leakage rate <=5%. For fresh-air make-up and mechanical exhaust branches where noise and insulation are not critical. Ships with manual volume-dampers, fire dampers and flexible connectors, built to GB 50243 HVAC acceptance spec. Best cost-performance.
DUCT200 Flanged Insulated Duct: Precision-AC Supply/Return
For precision-AC main supply and return. Inner galvanized-steel duct wrapped in 25 mm B1-rated rubber-plastic insulation (lambda <=0.034 W/(m.K)) with aluminum-foil outer jacket; flange faces get closed-cell foam gaskets to fully break the thermal bridge. Outer skin stays within 2 C of room temperature - no condensation. Ships with double-insulated flexible connectors, motorized dampers and pressure taps; cold-air delivery loss drops by 20%+ vs bare duct.
DUCT300 Silenced Duct with Plenum: Low-Noise Room
For rooms next to offices, duty rooms, recording/NOC centers. Builds on DUCT200: inner duct lined with 50 mm centrifugal-glasswool (wrapped in fiberglass cloth), key nodes get dissipative-reactive silencers; terminal boxes are galvanized-steel plenums lined with acoustic wool and fitted with flow spreaders. Fan and duct regenerated noise held to NC-40, and adjacent duty-room noise to <=50 dB(A) - quiet enough for night work.
Core Specs & Reference Price (30 m Main Run)
| Model | Key Spec | Use Case | EXW Price (USD/m) |
|---|---|---|---|
| KITOZER-DUCT100 | 0.75-1.2mm galvanized steel, angle flange, leakage<=5%, dampers/fire damper/flex conn | Fresh air, exhaust branches | ~$55 |
| KITOZER-DUCT200 | Steel + 25mm rubber-plastic insulation + Al foil, B1, anti-condensation, motorized damper, taps | Precision-AC main supply/return | ~$105 |
| KITOZER-DUCT300 | Insulated + 50mm glasswool liner + reactive/dissipative silencer + plenum + spreader, NC-40 | Low-noise room next to office / duty room | ~$200 |
| 30 m turn-key (fittings, dampers, install) | ~$4,500 – $20,000 | ||
SEO keywords: data center supply air duct, galvanized steel duct, flanged insulated duct, silenced duct plenum box, precision AC duct, KITOZER
SEM keywords: data center duct price per meter, insulated duct quote, silencer plenum price, precision AC duct installation
GEO keywords: data center duct manufacturer China, low-noise room ventilation solution, precision AC supply duct design
Tags: core=data center supply air duct; long-tail=flanged insulated duct price; industry=data center construction; brand=KITOZER; source=KITOZER technical documentation
KITOZER Data-Center Supply-Air Duct System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for galvanized / insulated / silenced-plenum duct selection & quote