Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32
KITOZER
KITOZER
, , ,

Indoor EMI/RFI Shielded Cabinet | KITOZER

Indoor Integrated Shielding Cabinet – S-2000 Series Electromagnetic Interference (EMI) Protection for Critical Data & Eq

KITOZER indoor EMI RFI shielded cabinet KITOZER indoor EMI RFI shielded cabinet KITOZER indoor EMI RFI shielded cabinet KITOZER indoor EMI RFI shielded cabinet

Indoor Integrated Shielding Cabinet – S-2000 Series

 
Electromagnetic Interference (EMI) Protection for Critical Data & Equipment
 

 

Product Overview

 
The S-2000 Indoor Integrated Shielding Cabinet is a high-performance, all-in-one enclosure engineered to protect sensitive electronic systems, server hardware, and communication equipment from electromagnetic interference (EMI), radio frequency interference (RFI), and environmental hazards. Built from robust cold-rolled steel with precision-engineered shielding layers, this cabinet delivers unmatched performance for data centers, industrial control rooms, and enterprise IT environments.
 
Designed for seamless integration into modern infrastructure, the S-2000 combines advanced shielding technology, efficient thermal management, and user-centric design to ensure your critical systems operate reliably, securely, and without disruption.
 

 

Key Product Features & Benefits

 

1.Superior Electromagnetic Shielding

 
  • Multi-layered Construction: The cabinet’s cold-rolled steel body, combined with conductive gaskets and precision seams, is designed to support EMI/RFI isolation for indoor equipment. Shielding performance and test class are confirmed per project.
  • Isolated Environment: Prevents external electromagnetic interference from disrupting sensitive server, network, and control equipment, while containing internal emissions to comply with regulatory requirements.
  • Secure Access: Heavy-duty locking mechanisms (including combination locks and keyed entry) ensure only authorized personnel can access critical systems, reducing the risk of tampering and data breaches.
 

2. Efficient Thermal Management

 
  • Enhanced Heat Dissipation: Equipped with high-performance fans, large ventilation grilles, and optimized airflow paths, the S-2000 uses active ventilation and airflow paths to support heat dissipation, maintaining optimal operating temperatures for sensitive hardware.
  • Smart Temperature Control: Temperature sensors and fan control can be specified for the project. Cooling performance is confirmed per project.
  • Dual Ventilation Zones: Front and rear ventilation panels, paired with internal ducting, support airflow for the selected indoor configuration. Cooling performance is confirmed per project.
 

3.Easy Installation & Integration

 
  • All-in-One Design: Pre-configured mounting rails, cable management trays, and power distribution units (PDUs) help installation. Installation scope and schedule are confirmed per project.
  • Standardized Compatibility: Compatible with 19-inch rack-mounted servers, switches, and storage devices, making it a versatile solution for diverse IT environments.
  • Secure Foundation: M12 bolt-down points ensure the cabinet is securely anchored to the floor, while dedicated grounding terminals can be provided. Grounding and shielding details are confirmed per project.
 

4. Scalable & Modular Architecture

 
  • Cluster-Ready Design: The S-2000 can be seamlessly integrated into multi-cabinet shielding clusters, allowing for scalable expansion as your infrastructure grows.
  • Modular Components: Swappable fan units, filter panels, and access panels enable easy maintenance and upgrades without disrupting operations.
  • Cable Management: Integrated cable routing channels and tie points keep organized, reducing signal interference and simplifying troubleshooting.
 

5.Durability & Environmental Resilience

 
  • Industrial-Grade Construction: Cold-rolled steel construction with anti-corrosion coatings ensures long-term durability in demanding indoor environments, including data centers and industrial facilities.
  • Indoor Environmental Protection: While optimized for indoor use, the cabinet’s sealed design provides resistance to dust and minor moisture, protecting equipment from environmental contaminants.
  • Long-Term Reliability: Warranty and technical support hours are confirmed on the project quotation.
 

 

Technical Specifications

 
表格
 
 
 
SpecificationDetails
MaterialCold-rolled steel with anti-corrosion coating
Shielding EffectivenessShielding performance is specified per project; test reports are provided when required
Thermal PerformanceActive ventilation; rating confirmed per project
DimensionsCustomizable to fit 19-inch rack equipment (height: 42U–52U, width: 600mm–800mm, depth: 800mm–1200mm)
Weight150–250 kg (depending on configuration)
AccessCombination lock + keyed entry; dual-door options available
WarrantyConfirmed on the project quotation
SupportSupport coverage confirmed on the project quotation
 

 

Ideal Applications

 
  • Data Centers: Protect server clusters and network infrastructure from EMI and ensure uninterrupted operations.
  • Industrial Control Rooms: Shield PLCs, SCADA systems, and communication equipment from factory floor interference.
  • Enterprise IT Environments: Secure critical servers, storage, and networking hardware in office and data center settings.
  • Research & Development: Isolate sensitive lab equipment from external electromagnetic noise to ensure accurate test results.
  • Telecommunication Facilities: Safeguard base station and core network equipment from RFI and environmental hazards.
 

 

Why Choose the S-2000 Indoor Integrated Shielding Cabinet?

 
KITOZER S-2000 indoor shielded cabinets are used to isolate EMI/RFI around servers, network and control equipment. Dimensions, accessories, shielding performance and support terms are confirmed on the project quotation. Request a Quote for This Shielded Cabinet
 
Request a quotation for the S-2000 Indoor Integrated Shielding Cabinet and experience the difference that purpose-built EMI protection can make for your critical systems. Request a project-specific quotation for configuration and support, this cabinet is more than a product—it’s a long-term investment in the reliability and security of your organization.
 
Brand

KITOZER

Series

S-2000

Product Type

Indoor EMI/RFI shielding cabinet

Application Environment

Indoor

Material

Cold-rolled steel

Surface Finish

Anti-corrosion coating

Rack Compatibility

19-inch

Height Range

42U-52U customizable

Width Range

600-800 mm customizable

Depth Range

800-1200 mm customizable

Access

Combination lock, Keyed entry, Dual-door option

Fixing

M12 floor bolt-down points

Grounding

Dedicated grounding terminals