TogglePut a Home 3-HP Split in the Server Room? Racks Start Overheating by Summer
When a small server room is built on the cheap, a household 3-HP split air conditioner is the first thing hauled in – only to see rack inlet temperature climb to 32C and humidity alarms go off before summer ends. Room AC and precision AC are not the same thing: server rooms need 24/7/365 cooling, constant humidity, high airflow with small enthalpy difference, and N+1 redundancy. KITOZER precision air-conditioning for constant-temp/constant-humidity rooms comes in three tiers – 5kW upright, 20kW in-row, and 100kW chilled-water group control – sharing one DCIM/BMS protocol, so you pay only for the cooling density you actually have. Reference prices range from $3,900 to $36,500.

KITOZER precision AC for constant-temp/constant-humidity rooms (three tiers: TEMP100 5kW upright / TEMP200 20kW in-row / TEMP300 100kW chilled-water + group control)
TEMP100 5kW Upright Precision AC: Starter for Small Closets
Upright direct-expansion (DX) air-cooled unit, 5kW sensible cooling, 1200m3/h airflow, EC fans, 3kW electric reheat + 2kg/h electrode humidification, 22~24C +/-1C and 45%~55% +/-5% RH. Top- or bottom-supply option, R410A, 380V/50Hz, RS485/Modbus plus dry-contact alarms, supports 2-unit N+1. For 10~20m2 rooms with 5~10 racks at 3~5kW per rack – small IT rooms, weak-current closets, control rooms – replacing the household split.
TEMP200 20kW In-Row AC: Near-Rack Cooling for Dense Racks
In-row deployment, only 300mm deep, 20kW sensible cooling, variable-speed EC fans, air-cooled DX. With hot/cold aisle containment it blows cold air straight at the rack inlet, eliminating hot spots. 6kW reheat + 5kg/h humidification, group control up to 8 rotating units, RS485/BACnet/IP to DCIM. For 50~100m2 rooms with 20~40 racks at 6~12kW per rack – medium data centers, small AI inference rooms – no more long-throw high-volume cooling.
TEMP300 100kW Chilled Water + Group Control: Central Plant for Large Rooms
Chilled-water air-handler (CRAH), 100kW sensible per unit, 7/12C chilled water inlet, variable-speed EC fans, VSD pump interface and group-control master, up to 32 CRAHs scheduled, rotated and auto-failover. Paired with chillers, plate exchangers and thermal storage as a central plant; the group-control dashboard shows each CRAH’s supply air temp/RH, pump speed and cooling share in real time. For 300m2+ modular data centers and IDCs at 10~15kW per rack – chilled water delivers cooling to every row.
Three-Tier Core Config & Reference Price
| Model | Core Spec | EXW Price (USD) |
|---|---|---|
| KITOZER-TEMP100 | 5kW sensible / air-cooled DX / EC fan / 3kW reheat + 2kg humid / top or bottom supply / RS485+dry contact / 1 pc | $3,900 |
| KITOZER-TEMP200 | 20kW sensible / in-row / air-cooled DX / 6kW reheat + 5kg humid / BACnet/IP / up to 8-unit group / 1 pc | $9,100 |
| KITOZER-TEMP300 | 100kW sensible / chilled-water CRAH / variable-speed EC / VSD pump / group master / 32-unit cluster / 1 pc | $25,200 |
| Group-control / DCIM software license | Unit rotation, failover, temp/RH wallboard, SMS alarm, 1 set | $2,100 |
| Install / refrigerant / water piping / accessories & commissioning | Copper piping, condensate line, water/air ducts, rigging, on-site setup, 1 job | $4,500 |
| Typical whole-project reference (incl. accessories & setup) | ~$3,900~$36,500 | |
SEO keywords: precision air conditioner, constant temp humidity room, in-row cooling, chilled-water CRAH, data center group control, high airflow low enthalpy, KITOZER
SEM keywords: precision AC price, 20kW in-row cooler, 100kW chilled-water CRAH, server room precision AC selection
GEO keywords: precision AC vendor China, constant-temp constant-humidity room solution, data center group-control AC
Tags: core=precision air conditioner; long-tail=20kW in-row cooling price; industry=data center HVAC; brand=KITOZER; source=KITOZER technical documentation
KITOZER Precision AC for Constant-Temp/Humidity Rooms
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for 5kW upright / 20kW in-row / 100kW chilled-water group-control selection & pricing