Rack PDU Buying Guide: KITOZER Metered vs Switched Power Distribution Units

Rack Power Distribution Units: From Basic to Smart PDU

A rack PDU (Power Distribution Unit) is the backbone of rack power delivery. KITOZER offers three tiers: basic, metered, and switched. This guide helps you select the right level of intelligence for your deployment.

PDU Tier Comparison

Feature Basic (KZ-PDU-B) Metered (KZ-PDU-M) Switched (KZ-PDU-S)
Power Distribution ✓ ✓ ✓
Surge Protection ✓ ✓ ✓
Digital Current Display ✗ ✓ ✓
Per-Outlet Monitoring ✗ ✗ ✓
Remote On/Off Outlet ✗ ✗ ✓
Network Interface ✗ RJ45 (SNMP) RJ45 (SNMP/HTTP)
Alarm Thresholds ✗ ✓ ✓
Outlet Types 8×C13 + 2×C19 8×C13 + 2×C19 12×C13 + 4×C19
Rated Current 16A 16A 32A
Input Plug IEC 60309 16A IEC 60309 16A IEC 60309 32A
Reference Price $85 $220 $480

When to Choose Which Tier?

Basic PDU:

Small server rooms, single-rack deployments, non-critical equipment. The basic PDU provides safe distribution with surge protection but no monitoring.

Metered PDU:

Multi-rack data centers where power monitoring is needed at rack level. The digital display shows real-time current draw. SNMP integration enables remote monitoring via DCIM software. Recommended for 5+ rack deployments.

Switched PDU:

Critical infrastructure requiring remote power cycling. Per-outlet control allows rebooting hung servers without on-site visit. Overload protection per outlet. Ideal for colocation and unmanned sites.

Installation Notes

  • Mount vertically (0U) in the rack cable management channel
  • Use the correct input plug for your facility circuit
  • Balance loads across A/B power feeds for redundant configurations
  • C13 outlets serve standard servers; C19 outlets for high-power servers (≥3kW)
  • Max 80% load per PDU (derating for safety)

SEO Tags

Core: rack PDU, power distribution unit, metered PDU, switched PDU

Long-tail: 16A rack PDU, C13 C19 power strip, smart PDU with monitoring, KITOZER PDU

Brand: KZ-PDU series, KITOZER power distribution

Meta Title: Rack PDU Buying Guide | KITOZER Basic vs Metered vs Switched PDU

Meta Description: Compare basic, metered and switched rack PDUs. KITOZER PDU series with C13/C19 outlets, surge protection and SNMP monitoring. Pricing and selection guide.

Contact

Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER)
Phone/WeChat: +86 13922289957 / +86 18520668845
WhatsApp: +86 19068534140
Web: www.lain.com.cn | www.gdlain.com
Address: Chaotian Park, Zhongrun Industrial Zone, Shilou, Panyu, Guangzhou, China

Shopping Cart