Racks Overheating and Static Demage? Lightning Protection and Grounding Is Often the Missing Half

Racks Overheating and Static Demage? Lightning Protection and Grounding Is Often the Missing Half

Surge protective devices are installed everywhere in a server room, but the equipotential grounding network is often done as an afterthought – so surge currents cannot be discharged, static kills modules in winter, and potential differences between racks burn interfaces. The KITOZER data-center lightning protection & grounding system delivers everything in one go: galvanized flat steel under the raised floor, copper terminal plates, pipe-bonding straps and SPD surge protection. Reference price about $5,100.

KITOZER data center lightning protection grounding equipotential bonding copper busbar SPD surge protective device
KITOZER data-center lightning protection & grounding (copper equipotential busbar + SPD + bonding)

Equipotential Grounding Grid: From Raised Floor to Ground Main

Galvanized grounding flat steel (15x20x0.08) is laid under the anti-static raised floor, with bonding nodes every 600-2000 mm. Each node uses a 4 mm-thick copper terminal plate fixed with M6 galvanized bolts, nuts and washers; 16 mm2 DVR grounding conductors tie row-end racks, power distribution cabinets and cable trays back to the nearest node. Copper braided straps bridge rack door frames to floor supports, keeping all metalwork at the same potential so static and common-mode noise discharge straight to ground.

SPD Surge Protection + Pipe Bonding: Divert Lightning Current to Earth

Class-rated SPDs are installed on both power and signal feeders, so transient over-voltage is clamped and discharged through the grounding main. Ducts, trays and metal pipes are bonded every 3 points with 6 mm2 straps and -25×4 jumpers, M10 galvanized bolts with spring lock washers; solder joints ensure stable contact resistance. The package includes installers and solderers, plus a post-install test of ground resistance and continuity.

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
Grounding flat steel Galvanized 15x20x0.08, 15m typical run under raised floor $1,000
Copper terminal plate 4 mm thick, 5 nodes, M6 galvanized bolt/nut/washer set $100
Grounding & bonding conductor DVR 16 mm2 ground wire + 6 mm2 pipe bonding strap $200
Equipotential connector -25×4 galvanized jumpers / links / clamps $300
Galvanized hardware kit M6/M10 bolts, nuts, spring washers, clamps full set $200
Install / solder / bonding commissioning Raised-floor grounding + pipe bonding, soldering, testing $3,300
Total reference (doubled) ~$5,100

SEO keywords: data center lightning protection, equipotential bonding, grounding flat steel, copper terminal plate, SPD surge protector, raised-floor grounding, KITOZER

SEM keywords: server room grounding cost, equipotential grounding grid installation, SPD surge protective device, copper grounding bar

GEO keywords: data center lightning protection vendor China, server room equipotential solution, grounding engineering company

Tags: core=data center lightning protection & grounding; long-tail=equipotential grounding grid installation cost; industry=data center / server room engineering; brand=KITOZER; source=KITOZER technical documentation

KITOZER Data Center Lightning Protection & Grounding
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for server-room equipotential grounding, SPD surge protection & raised-floor bonding

Scroll to Top