ToggleRacks Overheating and Static Demage? Lightning Protection and Grounding Is Often the Missing Half
Surge protective devices are installed everywhere in a server room, but the equipotential grounding network is often done as an afterthought – so surge currents cannot be discharged, static kills modules in winter, and potential differences between racks burn interfaces. The KITOZER data-center lightning protection & grounding system delivers everything in one go: galvanized flat steel under the raised floor, copper terminal plates, pipe-bonding straps and SPD surge protection. Reference price about $5,100.

KITOZER data-center lightning protection & grounding (copper equipotential busbar + SPD + bonding)
Equipotential Grounding Grid: From Raised Floor to Ground Main
Galvanized grounding flat steel (15x20x0.08) is laid under the anti-static raised floor, with bonding nodes every 600-2000 mm. Each node uses a 4 mm-thick copper terminal plate fixed with M6 galvanized bolts, nuts and washers; 16 mm2 DVR grounding conductors tie row-end racks, power distribution cabinets and cable trays back to the nearest node. Copper braided straps bridge rack door frames to floor supports, keeping all metalwork at the same potential so static and common-mode noise discharge straight to ground.
SPD Surge Protection + Pipe Bonding: Divert Lightning Current to Earth
Class-rated SPDs are installed on both power and signal feeders, so transient over-voltage is clamped and discharged through the grounding main. Ducts, trays and metal pipes are bonded every 3 points with 6 mm2 straps and -25×4 jumpers, M10 galvanized bolts with spring lock washers; solder joints ensure stable contact resistance. The package includes installers and solderers, plus a post-install test of ground resistance and continuity.
Core Configuration & Reference Price (doubled)
| Item | Spec | EXW Price (USD) |
|---|---|---|
| Grounding flat steel | Galvanized 15x20x0.08, 15m typical run under raised floor | $1,000 |
| Copper terminal plate | 4 mm thick, 5 nodes, M6 galvanized bolt/nut/washer set | $100 |
| Grounding & bonding conductor | DVR 16 mm2 ground wire + 6 mm2 pipe bonding strap | $200 |
| Equipotential connector | -25×4 galvanized jumpers / links / clamps | $300 |
| Galvanized hardware kit | M6/M10 bolts, nuts, spring washers, clamps full set | $200 |
| Install / solder / bonding commissioning | Raised-floor grounding + pipe bonding, soldering, testing | $3,300 |
| Total reference (doubled) | ~$5,100 | |
SEO keywords: data center lightning protection, equipotential bonding, grounding flat steel, copper terminal plate, SPD surge protector, raised-floor grounding, KITOZER
SEM keywords: server room grounding cost, equipotential grounding grid installation, SPD surge protective device, copper grounding bar
GEO keywords: data center lightning protection vendor China, server room equipotential solution, grounding engineering company
Tags: core=data center lightning protection & grounding; long-tail=equipotential grounding grid installation cost; industry=data center / server room engineering; brand=KITOZER; source=KITOZER technical documentation
KITOZER Data Center Lightning Protection & Grounding
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for server-room equipotential grounding, SPD surge protection & raised-floor bonding