Room-Level Precision Air Conditioner KITOZER-PAC-ROOM Chilled-Water CRAH Price

KITOZER-PAC-ROOM: Floor-Standing Room-Level Precision Air Conditioner for Data Centers (Chilled-Water CRAH)

A medium-to-large airflow precision cooling platform for data center rooms, network rooms and equipment rooms. Single-unit cooling from 20 to 81 kW, with EC centrifugal fans, full-inverter compressor and electronic expansion valve, temperature/humidity accuracy of +/-1 C / +/-3% RH, and multi-unit N+1 redundant group-control rotation.

Room-level floor-standing
Chilled-water CRAH
EC centrifugal fans
+/-1 C / +/-3% RH
N+1 group control
Year-round cooling
20-81 kW range

1. Positioning: how it differs from wall-mounted small units

KITOZER-PAC-ROOM is a room-level, floor-standing precision air conditioner by KITOZER (Guangzhou Lain Intelligent System Development Co., Ltd.), designed for medium-size data center rooms, telecom equipment rooms and equipment spaces. It uses chilled water as the cooling source and covers single-unit capacities of 20, 25, 80 and 81 kW, providing whole-room constant temperature and humidity control with large airflow and a high sensible-heat ratio.

It sits in a different class from the wall-mounted small-capacity units (3.5-5 kW for 4-5 sqm small rooms). Wall-mounted units bolt onto a wall, have limited capacity and short throw, and only suit a single small equipment room. KITOZER-PAC-ROOM is a floor-standing cabinet with large capacity and high airflow, organizing whole-room air circulation via top supply and side return to eliminate hot spots – the workhorse for room-level and larger data centers.

2. Why data centers need room-level precision cooling

IT gear generates heat 24/7, almost entirely as sensible heat. Comfort air conditioners are designed for people, have a low sensible ratio, constantly dehumidify and cycle on and off – unstable and inefficient. Room-level precision units are designed for equipment heat loads:

High sensible ratio
Sensible ratio >=0.9; cooling goes mostly toward temperature rather than dehumidification, avoiding repeated over-drying and re-humidifying.
Large airflow, small delta-T
Airflow matched to 250-300x the cooling capacity, giving small supply/return delta-T and a uniform room temperature field with no hot spots.
Continuous duty
Built for 24/7 x 365 operation over a wide ambient range, suited to the steady heat load of a data hall.
Constant temp & humidity
+/-1 C and +/-3% RH, with a dedicated humidity module that automatically humidifies/dehumidifies for long-term equipment stability.

3. Core components: EC fans + inverter + EEV

Inside the cabinet, a chilled-water coil and EC centrifugal fans do the work. Chilled water comes from the customer’s chiller plant, enters the coil and exchanges heat with the room’s return air; the EC fans push cooled air through a supply plenum into the room.

EC centrifugal fans use brushless DC motors and modulate continuously to the room load – high efficiency at part load and lower noise. The electronic expansion valve precisely meters the water/refrigerant flow, and the full-inverter compressor delivers cooling on demand, saving energy over fixed-speed systems. Built-in self-diagnostics and refrigerant/water-side anomaly detection show key parameters in real time for fast maintenance.

4. Sizing: right-sizing to room heat load

Room-level units are sized to the total room heat load with redundancy. The typical method:

1) Envelope load: room shell, lighting and people, estimated at 0.18 kW/sqm;

2) Equipment load: IT power x 0.8 to estimate equipment heat rejection;

3) Total load = (envelope + equipment) x 1.2 safety factor;

4) Airflow ~ cooling (kW) x 250-300 m3/(h.kW) for a uniform temperature field;

5) Redundancy: N+1 – after meeting the load, add one backup unit.

Worked example: a ~200 sqm room with 120 kW IT load. Equipment heat ~= 120 x 0.8 = 96 kW; envelope ~= 200 x 0.18 = 36 kW; total = (96+36) x 1.2 ~= 158 kW. Select 2 x 80 kW units and add one more for N+1 – i.e. 3 x KITOZER-PAC-ROOM-80kW rotating, so if one fails the others still hold the room.

5. N+1 redundancy and group-control rotation

Multiple KITOZER-PAC-ROOM units network through the KITOZER-ENV-DH10 touchscreen for rotation and dynamic cooling allocation. Units wear evenly and back each other up; when one fails or is serviced, the others ramp up automatically so cooling is never interrupted. The screen centralizes temperature/humidity, status and alarms, and links to the DCIM via RS485/SNMP for remote, unattended monitoring.

6. Two cooling-source options: chilled water vs direct-expansion air-cooled

This configuration is chilled-water (CRAH): supply/return 15/21 C, water-side pressure drop <=80 kPa; the chiller plant, pumps and main piping are customer-supplied. The KITOZER-PAC-ROOM family also offers a direct-expansion air-cooled variant paired with a KITOZER-PAC-ODU outdoor unit (inverter compressor, R410A refrigerant), for rooms without a central chiller plant. Indoor units share the same footprint, group-control interface and temp/humidity accuracy.

7. Key specifications

Item Specification
Type Floor-standing, room-level; chilled-water (this config) / DX air-cooled (optional)
Single-unit cooling 20 / 25 / 80 / 81 kW (24 C / 50% RH condition)
Chilled water 15/21 C supply/return; pressure drop <=80 kPa
Airflow Top supply (with plenum), side return
Temp accuracy +/-1 C (18-28 C adjustable)
Humidity accuracy +/-3% RH (40-60% RH adjustable, constant temp/humidity type)
Fans EC centrifugal fans, variable speed
Expansion device Electronic expansion valve
Power supply 380 V 3-phase, surge protection, wide-voltage tolerance
Group control KITOZER-ENV-DH10 touchscreen, N+1 rotation, RS485/SNMP to DCIM

8. KITOZER Price List (USD, before tax)

No. Model Item Specification Qty Unit Unit Price (USD) Amount (USD)
1. Room-level precision AC units (chilled water)
1 KITOZER-PAC-ROOM-20kW Inverter room precision AC 20kW 20 kW, 2 kW/380V, 15/21 C, dP<=80kPa, 800x1000x2000mm, top supply/side return with plenum, EC fan, EEV 2 unit 65,833 131,666
2 KITOZER-PAC-ROOM-25kW Inverter room precision AC 25kW 25 kW, 2 kW/380V, 15/21 C, dP<=80kPa, 2200x1000x2000mm, +/-1 C / +/-3% RH 2 unit 70,000 140,000
3 KITOZER-PAC-ROOM-80kW Inverter room precision AC 80kW High airflow, 80 kW, 5 kW/380V, 15/21 C, dP<=80kPa, 2200x1000x2000mm, twin EC fans, dual coil circuit option 3 unit 100,833 302,499
4 KITOZER-PAC-ROOM-81kW Inverter room precision AC 81kW High airflow, 81 kW, 5 kW/380V, 15/21 C, dP<=80kPa, top supply/side return with plenum, N+1 group rotation 2 unit 103,333 206,666
2. Humidity & group control
5 KITOZER-ENV-H10 Dedicated room humidity module Humidify 10 L/h, dehumidify 6 kg/h, 5.5 kW/380V, 1200x600x2000mm, linked to group control, holds 40-60% RH 3 unit 49,167 147,501
6 KITOZER-ENV-DH10 PAC group-control / environment touchscreen 10-inch touchscreen, N+1 rotation scheduling, central temp/humidity display and alarms, RS485/SNMP to DCIM 1 set 4,083 4,083
3. Installation accessories
7 KITOZER-JZ-300 Dedicated PAC mounting frame Galvanized floor frame, load >=230 kg, fits 800-2200 mm cabinets, anti-vibration pads and bolts 12 set 778 9,336
– – KITOZER total (before tax) 7 line items – – – 941,751

9. Price notes

  • KITOZER equipment prices are before tax; VAT invoice per the agreed tax treatment.
  • This configuration is the chilled-water room-level system; chillers, chilled-water pumps and main piping are customer-supplied and not included.
  • A direct-expansion air-cooled variant with KITOZER-PAC-ODU outdoor units is available, priced to the selected capacity range.
  • Prices include factory-to-site transport, positioning/installation and commissioning; they exclude civil works, chilled-water external piping and power utility upgrades.
  • Unit counts are sized to the actual room heat load and N+1 redundancy; prices adjust with IT load, room area or redundancy level.
  • Precision air conditioner prices are subject to copper and compressor raw-material markets and are finalized on the formal order.