A safety emergency container is a special emergency support equipment integrating safety protection, emergency command, monitoring and early warning, and emergency refuge. It uses a high-strength container as the carrier, and integrates security monitoring, gas detection, firefighting, emergency communication, and personnel refuge systems. Designed for high-risk scenarios such as chemical parks, underground mines, oil and gas stations, and tunnel engineering, it serves as an on-site safety monitoring center and emergency refuge shelter, providing safety guarantees and emergency command platforms for workers. With explosion-proof, fireproof, anti-toxic, and pressure-resistant capabilities, it offers temporary safe shelter during sudden accidents while supporting on-site safety monitoring and emergency command functions.

Product Introduction

The safety emergency container is an integrated security protection and emergency response solution. It is based on a heavy-duty container body with multiple protective systems including environmental monitoring, positive pressure ventilation, life support, fire suppression, and communication. It is suitable for chemical plants, mines, oil and gas fields, tunnels, and other high-risk workplaces. The container ensures personnel safety and enables effective emergency management.

Product Positioning

Positioned as a mobile safety hub and emergency refuge unit for high-risk scenarios, it serves chemical, mining, petroleum, electric power, tunnel construction and other high-risk industries. It functions as an on-site safety management center, emergency command station, and emergency refuge shelter, combining daily safety monitoring with accident emergency refuge. It is a core hardware facility for enterprise safety production and emergency support systems.

Core Value

  • Safety Protection Value: With multiple protections like explosion-proof, fireproof, anti-toxic, heat insulation, and pressure resistance, it provides a safe refuge space in accident conditions.
  • Monitoring and Early Warning Value: Integration of various environmental sensors provides 24-hour monitoring of hazardous gases, temperature, smoke, and other parameters, allowing early risk warnings.
  • Emergency Command Value: Equipped with a communication and command system, it can serve as an on-site emergency command post during incidents to coordinate rescue operations.
  • Rapid Deployment Value: Overall lifting and transportation enable plug-and-play use, suitable for construction sites, temporary work points, and other mobile scenarios.
  • Compliance Guarantee Value: Meets safety production regulations for emergency facilities, helping enterprises pass safety production standardization acceptance.

Product Highlights

  • Explosion-proof rating Ex d IIB T4, suitable for flammable and explosive environments.
  • Positive pressure ventilation system prevents toxic gas intrusion.
  • Integration of multiple gas detectors for real-time monitoring of combustible and toxic gas concentrations.
  • Fireproof and heat-insulating structure ensures internal safety for over 30 minutes under external fire.
  • Independent oxygen supply and life support system maintains personnel survival for more than 24 hours in refuge mode.
  • Explosion-proof communication system for uninterrupted contact during incidents.
  • Complies with national safety production standards and meets safety inspection requirements.

Product Types and Composition

Product Types

According to function and protection level, the products can be classified into:

  • Safety Monitoring Container: Mainly for routine safety monitoring and command, used in parks and factory safety monitoring centers.
  • Emergency Refuge Container: Enhanced life support system, serves as emergency refuge shelter for personnel during accidents.
  • Explosion-Proof Safety Container: Fully explosion-proof design for flammable and explosive dangerous areas.
  • Comprehensive Safety Command Container: Combines monitoring, command, refuge, and communication functions.

System Composition

The safety emergency container consists of the following subsystems:

  • Container Protection System: Explosion-proof body, fireproof insulation layer, sealing structure, reinforced frame.
  • Environmental Monitoring System: Combustible gas detector, toxic gas detector, oxygen detector, temperature/humidity sensor, smoke alarm.
  • Ventilation and Air Curtain System: Positive pressure ventilation, air filtration, air exchange system.
  • Life Support System: Oxygen supply unit, COâ‚‚ absorption unit, emergency food and water, sanitary facilities.
  • Firefighting System: Aerosol extinguisher, dry powder extinguisher, fireproof door, fire shutter.
  • Communication Command System: Explosion-proof telephone, explosion-proof intercom, emergency broadcast, video surveillance, display terminal.
  • Electrical Power Supply System: Explosion-proof distribution cabinet, UPS power, explosion-proof lighting, emergency lighting.
  • Safety Warning System: Audible and visual alarm, warning light, emergency sign, escape indication.

System Working Principle

The safety emergency container adopts a three-level safety design principle of “active monitoring + passive protection + emergency support”. During normal operation, the environmental monitoring system collects on-site gas, temperature, smoke, and other data 24 hours a day and transmits it to the monitoring platform. Once parameters exceed limits, it immediately triggers audible and visual alarms and activates the ventilation system for enhanced air exchange. In the event of explosion, fire, toxic gas leakage, or other accidents, the high-strength container structure and fireproof insulation layer resist external impact and high temperature. The positive pressure ventilation system starts and closes the ventilation valve, maintaining positive pressure inside to prevent toxic gas ingress. The life support system activates oxygen supply and air purification to ensure the survival of occupants. The communication system maintains contact with the outside and provides information support for external rescue.

The entire system adopts dual power supply and dual-link redundancy design to ensure continuous operation of core equipment during power outages, safeguarding the safety and communication of refuge personnel.

Technical Parameters

Parameter Category Specific Indicator
— —
External Dimensions 20ft: 6058×2438×2896mm; 40ft: 12192×2438×2896mm
Explosion-Proof Rating Ex d IIB T4 Gb (explosion-proof type)
Protection Rating IP65
Fire Resistance Limit ≥30 minutes (Class A fire protection)
Positive Pressure Value 20~50Pa
Refuge Capacity 20ft: 8~12 people; 40ft: 20~30 people
Refuge Duration ≥24 hours for rated number of people
Operating Ambient Temperature -40℃ ~ +60℃
Monitored Gas Types Combustible gas, CO, Hâ‚‚S, Oâ‚‚, SOâ‚‚, etc. (optional)
Alarm Method Audible and visual alarm, remote alarm
Power Supply Mains + UPS dual power, UPS endurance ≥8 hours
Impact Pressure Resistance ≥0.3MPa
Container Weight 20ft: approx. 4.5~6.5 tons; 40ft: approx. 8~12 tons

Product Configuration List

No. Configuration Name Specifications/Model Quantity Remarks
— — — — —
1 Explosion-Proof Container Body 20ft/40ft reinforced type 1 set Explosion-proof certified
2 Fireproof Insulation Layer 100mm fire-resistant insulation material 1 set Class A fire protection
3 Positive Pressure Ventilation System Air volume 800m³/h, explosion-proof 1 set Includes filter
4 Explosion-Proof Distribution Cabinet 380V/220V, explosion-proof 1 unit Standard
5 UPS Uninterruptible Power Supply 6KVA 1 unit Endurance 8 hours
6 Explosion-Proof LED Lighting 40W explosion-proof lamp 4~8 lights Standard
7 Emergency Lighting Explosion-proof emergency light 2~4 lights Endurance 90 minutes
8 Combustible Gas Detector 0-100%LEL, explosion-proof 2~4 pieces Standard
9 Toxic Gas Detector CO/Hâ‚‚S/Oâ‚‚, explosion-proof 2 each Standard
10 Audible and Visual Alarm Explosion-proof, 120dB 2 pieces Standard
11 Aerosol Fire Extinguishing Device 3kg 2~4 pieces Standard
12 Explosion-Proof Communication Telephone Intrinsically safe type 1~2 units Standard
13 Oxygen Supply System Compressed oxygen cylinder + pressure reducing valve 1 set Standard for refuge type
14 COâ‚‚ Absorption Device Chemical absorption type 1 set Standard for refuge type
15 Video Surveillance System Explosion-proof camera + monitor 1 set Standard

Core Advantages

Material Advantages

The container body uses Q345R pressure vessel steel plate with thickness ≥6mm, providing high structural strength and excellent impact/pressure resistance. The insulation layer uses a composite structure of nano-microporous insulation material and refractory rock wool, with thermal conductivity ≤0.03W/(m·K) and fire resistance of over 30 minutes. Seals use fluororubber (FKM) material which is oil-resistant, corrosion-resistant, and high-temperature resistant, suitable for chemical environments. All electrical components are explosion-proof certified products meeting national explosion-proof standards.

Process Advantages

Utilizing pressure-vessel-grade welding technology, all main welds of the container body are double-sided welded and 100% ultrasonic flaw detection is performed to ensure structural strength and airtightness. The container body undergoes overall annealing treatment to eliminate welding stress and improve structural stability. Sealing surfaces are precision machined with flatness ≤0.1mm to ensure positive pressure sealing. Explosion-proof wiring uses specialized explosion-proof glands and follows standard wiring practices compliant with explosion-proof electrical standards.

Customization Advantages

  • Customizable explosion-proof rating, protection rating, and fire resistance limit based on site hazard levels.
  • Flexible configuration of monitored gas types/quantities and life support system scale.
  • Customizable internal functional zones: monitoring area, command area, refuge area, equipment area.
  • Support for door opening mode, observation windows, interfaces, and other details.
  • Exterior color and warning signs can be customized according to industry standards.

Cost Advantages

Integrated design reduces comprehensive cost by over 40% compared to fixed safety station construction. Relocatable and reusable, it can be transferred to next project after completion, maximizing asset utilization. Quick installation saves time and labor costs. Low maintenance requirement – no dedicated round-the-clock supervision needed.

Quality Advantages

Produced strictly according to GB 3836 explosion-proof standard and GB 50016 building fire protection standard. Products have passed the certification of the National Explosion-Proof Electrical Product Quality Supervision and Inspection Center. Before delivery, multiple functional tests are performed including airtightness, positive pressure maintenance, and alarm linkage. Core components are sourced from leading domestic explosion-proof brands, ensuring reliable quality and low failure rate.

Product Category Details

20ft Safety Monitoring Container

Basic safety monitoring unit with environmental monitoring, video surveillance, and communication command systems. Suitable for daily safety monitoring in chemical parks, factory gates, and small work sites.

20ft Emergency Refuge Container

Enhanced refuge shelter with complete life support system, accommodating 8~12 people for over 24 hours of emergency refuge. Suitable for high-risk areas such as mines, tunnels, and chemical plants.

40ft Explosion-Proof Safety Command Container

Comprehensive explosion-proof safety center with monitoring/command area, conference/consultation area, equipment room, and refuge area. Ideal as an on-site safety command center for large chemical plants, oil fields, and mines.

Mine-Specific Safety Container

Specially designed for underground environments: moisture-proof, anti-vibration, and pressure-resistant. Equipped with underground-specific communication and life support systems, meeting coal mine safety standards.

Customized Special Safety Containers

Higher protection levels such as fireproof/explosion-proof type, radiation-proof type, and chemical-resistant type can be customized based on customer requirements.

Materials and Process Analysis

Material Details

  • Container Steel Plate: Q345R pressure vessel steel plate, side plate thickness 6mm, end plate thickness 8mm, top plate thickness 8mm, bottom frame using 16# I-beam for strong impact and pressure resistance.
  • Heat Insulation and Fire Layer: Inner layer 50mm nano-microporous insulation board, outer layer 50mm high-density refractory rock wool, externally wrapped with 0.5mm galvanized steel sheet – composite structure combines heat insulation and fire resistance.
  • Sealing Material: Fluororubber (FKM) sealing strip, temperature range -20℃~+200℃, oil-resistant, chemical-corrosion-resistant, suitable for chemical hazardous environments.
  • Observation Window: Multi-layer composite fireproof and explosion-proof glass, total thickness 30mm, combining explosion-proof, fireproof, and heat-insulating functions.
  • Electrical Components: All are Ex d IIB T4 grade explosion-proof products with national explosion-proof certification.

Core Process Description

  • Pressure Vessel Welding Technology: Main welds adopt argon arc welding backing + manual welding cover, double-sided forming, 100% UT flaw detection, weld grade II and above.
  • Overall Annealing Process: After welding, the container body undergoes full stress relief annealing to eliminate welding internal stress and prevent deformation.
  • Precision Machining Process: Sealing surfaces such as door frames and flanges are precision machined with large gantry milling for high flatness, ensuring positive pressure sealing.
  • Airtightness Test Process: The entire container is pressurized to 100Pa and held for 2 hours; pressure drop ≤10Pa considered qualified, ensuring sealing performance.
  • Explosion-Proof Electrical Installation Process: Strictly in accordance with GB 3836, all wiring points use explosion-proof glands and reliable grounding.

Safety Certifications

  • Explosion-proof certificate from National Explosion-Proof Electrical Product Quality Supervision and Inspection Center
  • ISO9001 Quality Management System Certification
  • Fire product type inspection report
  • Coal mine mineral product safety mark certificate (for mine-specific type)
  • Electrical product 3C certification

Stock Availability Details

Conventional 20ft safety monitoring containers are available in stock and can be shipped within 72 hours. Explosion-proof and refuge types are made to order. Common accessories such as detectors, explosion-proof lights, and UPS are stocked for quick response to maintenance and upgrade needs.

OEM/ODM and Confidentiality Services

We provide OEM/ODM customization services for safety emergency containers. Production can be done according to customer technical requirements, supporting brand customization and neutral packaging. We sign strict confidentiality agreements to protect customer technical solutions, project information, and end-customer details. With explosion-proof product production qualification and rich experience, we can undertake OEM orders for special safety containers across industries.

Product Attributes (SKU)

SKU Code Product Name Specification Unit Remarks
— — — — —
LA-AQ-20J Safety Monitoring Container 20ft standard type Unit For monitoring and command
LA-AQ-20B Explosion-Proof Safety Container 20ft explosion-proof type Unit Ex d IIB T4
LA-AQ-20X Emergency Refuge Container 20ft refuge type Unit 12 people / 24 hours
LA-AQ-40Z Safety Command Container 40ft comprehensive type Unit Explosion-proof + command + refuge
LA-AQ-KJ Mine Safety Container Mine-specific custom type Unit Coal mine certification
LA-AQ-DZ Safety Emergency Container Customization Made to order Unit Special protection level

Specifications and Technical Parameters Table

Item 20ft Safety Monitoring Type 20ft Emergency Refuge Type 40ft Explosion-Proof Command Type
— — — —
External Dimensions (L×W×H) 6058×2438×2896mm 6058×2438×2896mm 12192×2438×2896mm
Internal Dimensions (L×W×H) 5800×2200×2400mm 5800×2200×2350mm 11900×2200×2400mm
Usable Area Approx. 12.8㎡ Approx. 12.8㎡ Approx. 26.2㎡
Explosion-Proof Rating Increased safety type Ex d IIB T4 Ex d IIB T4
Fire Resistance Limit 15 minutes 30 minutes 30 minutes
Rated Refuge Capacity – 12 people 30 people
Refuge Duration – 24 hours 24 hours
Positive Pressure Ventilation Volume 500m³/h 800m³/h 1500m³/h
UPS Capacity 3KVA 6KVA 10KVA
UPS Endurance 4 hours 8 hours 8 hours
Monitored Gas Types 4 types 6 types 8 types
Container Weight Approx. 4500kg Approx. 6200kg Approx. 11500kg
Protection Rating IP65 IP65 IP65

Application Scenarios

  • Chemical Industry: On-site safety monitoring and emergency refuge in chemical plants, tank farms, and device areas.
  • Mining Industry: Underground emergency refuge shelters and surface safety monitoring centers in coal and metal mines.
  • Oil and Natural Gas: Explosion-proof safety stations for oil fields, gas fields, oil transport stations, and LNG stations.
  • Tunnel Engineering: Safety refuge and monitoring command for railway and highway tunnel construction.
  • Electric Power: Safety monitoring and emergency command for substations and converter stations.
  • Warehousing and Logistics: Safety monitoring stations for dangerous goods warehouses and port hazardous chemical storage yards.
  • Emergency Rescue: Mobile safety monitoring and command stations for fire departments and safety supervision departments.

Customization Service Details

Customization Scope

  • Protection Level Customization: Different explosion-proof levels, fire resistance limits, and impact resistance strengths.
  • Monitoring System Customization: Addition of gas types, dust monitoring, radiation monitoring, etc.
  • Life Support Customization: Increased refuge capacity and extended refuge duration.
  • Functional Zone Customization: Independent offices, rest rooms, equipment rooms, and washrooms.
  • Interface Customization: Reserved pipeline, communication, and power interfaces.
  • Appearance Customization: Customized colors, warning signs, and enterprise logos.

Customization Process

  1. On-site Survey: Technicians conduct on-site survey to understand environment and requirements.
  2. Solution Design: Provide customized solution drawings, configuration list, and quotation.
  3. Technical Review: Both parties conduct technical review and confirm the solution.
  4. Contract Signing: Sign customization contract and pay deposit.
  5. Production: Production according to standards, cycle 20~40 days.
  6. Factory Inspection: Explosion-proof testing, functional testing, and issuance of test report.
  7. On-site Installation: Technicians install, debug, and train operators on site.
  8. Acceptance and Delivery: Customer acceptance and delivery of documentation.

Customization Advantages

  • Explosion-proof design qualification and rich high-risk scenario project experience.
  • Professional explosion-proof engineering team ensures compliant and reliable solutions that meet acceptance requirements.
  • Full in-house production ensures control over quality and delivery time.
  • One-stop service from survey, design, production, to installation and acceptance.
  • Complete certification documents and acceptance materials provided for customized products.

Successful Cases

Partner Clients

  • A major petrochemical group
  • A mining group
  • An oil field branch company
  • A tunnel engineering bureau
  • A hazardous chemical supervision detachment of an emergency management bureau

Case Highlights

  • Petrochemical Park Safety Project: Delivered 8 explosion-proof safety containers to a petrochemical park, distributed across various process areas as on-site safety monitoring stations and emergency refuge points. They passed safety supervision and performed well in multiple emergency drills.
  • Mine Refuge Project: Customized 12 underground emergency refuge containers for a metal mine, equipped with complete life support systems capable of accommodating 144 people simultaneously. Passed mine safety acceptance.
  • Tunnel Construction Safety Project: Provided 6 safety emergency containers for a highway tunnel project as construction safety monitoring and refuge points, adapting to complex tunnel environments and ensuring construction safety.

Procurement Service Guarantee

Supply Guarantee

We have our own professional explosion-proof container production line with mature technology and stable capacity. Strategic partnerships with well-known brands for core explosion-proof components ensure stable supply. Emergency projects can be given priority in production scheduling to guarantee delivery.

Quality Guarantee

Each product is produced in strict compliance with national explosion-proof and fire protection standards. Before delivery, comprehensive testing is performed and an ex-factory inspection report is issued. Explosion-proof products come with formal explosion-proof certificates. Complete technical documentation and acceptance files are provided to assist customers in passing safety inspections.

Logistics Guarantee

We cooperate with professional large-item dangerous goods transport providers to ensure safe shipping. On-site installation and commissioning services are available. Delivery is available nationwide, including remote areas.

After-Sales Guarantee

  • 3-year whole-unit warranty, 5-year warranty for explosion-proof components, lifetime maintenance.
  • 7×24-hour technical service hotline, professional explosion-proof engineers for on-site service.
  • Regular inspections to ensure long-term stable operation.
  • Free operation training and safety guidance.

Invoice Guarantee

We can issue 13% VAT special invoices, which are authentic and verifiable, supporting payment after invoicing.

FAQ

Q1: Can the explosion-proof container be directly used in an explosion-proof area? Does it require approval?

A: Our explosion-proof products have obtained national explosion-proof certificates and comply with requirements for use in explosion-proof areas. They can be directly used in the corresponding hazardous areas. Installation and use require reporting to the safety supervision department as required. We provide complete certification materials to assist with acceptance.

Q2: How long can the emergency refuge container protect people during a fire?

A: The standard configuration has a fire resistance limit of 30 minutes, meaning the internal temperature stays within a safe range for over 30 minutes under external flames. This meets the waiting time for rescue in most accident scenarios. Higher fire resistance levels can be customized.

Q3: Which gases can the gas detectors measure? Can they be increased?

A: Standard configuration measures combustible gas, carbon monoxide, hydrogen sulfide, and oxygen. Additional detectors for chlorine, ammonia, sulfur dioxide, VOC, and other gases can be added to meet different scenario requirements.

Q4: Do the products require regular calibration? Do you provide calibration services?

A: Gas detectors require annual metrological calibration. We provide on-site calibration and maintenance services, or guide customers to send instruments for calibration, ensuring equipment accuracy and effectiveness.

Q5: Can you customize non-standard sizes according to our on-site dimensions?

A: Yes. We support non-standard size customization. Based on on-site space and usage requirements, we design exclusive solutions that fit the actual site.

Product Fault Handling Methods

Fault Phenomenon Possible Cause Handling Method
— — —
Gas detector alarm Gas concentration exceeds limit, sensor failure, calibration drift First ventilate to check for actual leakage; if no leakage, recalibrate; contact after-sales to replace sensor
Insufficient positive pressure Poor sealing, fan failure, blocked intake filter Check door and observation window sealing; check fan operation; replace air filter
Explosion-proof light does not turn on Circuit breaker trip, bulb damage, wiring fault Check explosion-proof distribution box switch; replace explosion-proof bulb; contact after-sales to check wiring
UPS alarm Mains power interruption, battery aging, overload Confirm mains status; reduce load; contact after-sales to inspect/replace battery
Audible/visual alarm false alarm Line interference, detector failure, improper parameter setting Check wiring; clean detector; reset alarm threshold
Container door does not close tightly Seal deformation, lock looseness, door frame deformation Adjust or replace seal; tighten lock; align door frame

Warning: In explosion-proof areas, it is strictly forbidden to open the cover for maintenance while powered. Power must be disconnected and environment safety confirmed before any operation!

Maintenance Guide

Monthly Maintenance

  • Clean the container surface and observation windows.
  • Check door sealing rubber strips and remove debris.
  • Check door locks and hinges, apply lubricant.
  • Test lighting and emergency lighting.
  • Check gas detector display for normal operation.

Quarterly Maintenance

  • Clean the ventilation system filter screen.
  • Test the alarm system functionality.
  • Check UPS operating status and battery voltage.
  • Check that grounding connections are secure.
  • Check the validity of firefighting devices.

Annual Maintenance

  • Full calibration of gas detectors and issuance of calibration report.
  • Comprehensive inspection of electrical system explosion-proof performance.
  • Check container anti-corrosion and sealing performance.
  • Test the positive pressure system airtightness.
  • Replace expired wearing parts and consumables.
  • Conduct overall functional test and safety assessment.

Factory Strength and After-Sales Service

Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER) has a professional R&D team for explosion-proof and safety protection products. We collaborate with multiple research institutes and testing agencies, possessing full-process capabilities for explosion-proof product design, production, and testing. Our production base is equipped with a dedicated explosion-proof electrical assembly workshop, airtightness test room, and environmental simulation laboratory, ensuring product quality meets national standards.

We have established a professional after-sales service team. Certified explosion-proof engineers provide installation, commissioning, calibration, and repair services to ensure safe and reliable operation in high-risk environments. All products have complete equipment files, and we regularly remind customers for maintenance and calibration, ensuring safety throughout usage.

Conclusion

Safety is the bottom line of production, and emergency response is the guarantee of life. As an important safety facility in high-risk scenarios, the safety emergency container carries the crucial mission of protecting personnel and supporting emergency command. Guangzhou Lain (KITOZER) always places safety quality first. With strict standards, reliable products, and professional service, we build a solid safety protection barrier for customers across industries.