Manufacturer: Guangzhou Lain Intelligent System Development Co., Ltd.
Document Version: V3.2
Release Date: July 2026
Table of Contents
ToggleChapter 1 Product Introduction

1.1 Product Definition
The Safety Isolation and Information Exchange System, referred to in the industry as a Network Gate (Gap), is a high-end network security protection device deployed at the boundary between two networks of different security levels. Based on the core technical concept of “physical isolation and data ferry,” it achieves controlled, secure, and compliant data exchange across security domains while completely severing direct TCP/IP protocol-layer connectivity. It is one of the highest security-grade isolation devices in current network boundary protection systems.
Unlike logical protection devices such as firewalls and intrusion prevention systems, the Network Gate achieves physical disconnection between internal and external networks at the hardware architecture level. There are no exploitable network session connections, enabling it to fundamentally resist penetration attempts based on protocol vulnerabilities, 0day vulnerabilities, and APT attacks. It is widely deployed in government affairs, energy, finance, industrial control, military, and other critical information infrastructure sectors with extremely high network security requirements.
1.2 Product Development History
The origin of Network Gate technology can be traced back to the “Air Gap” isolation concept of the 1990s. Early physical isolation solutions employed manual insertion/removal of storage media for data exchange, which was extremely inefficient and carried human operational risks. Around 1996, Israeli enterprises were the first to launch automated data ferry products based on dedicated hardware, marking the commercialization stage of Network Gate technology.
In the 21st century, with the advancement of China’s classified cybersecurity protection system, domestic Network Gate technology developed rapidly. From the initial single-purpose disc-writing ferry mode, it gradually evolved into the “dual-host + dedicated isolation chip” 2+1 architecture, and now to next-generation products supporting 10-gigabit throughput, deep parsing of industrial protocols, and localization of software and hardware adaptation. The security strength, performance, and protocol support capabilities of Network Gates have achieved qualitative leaps.
The LA-GAP series Network Gates launched by Guangzhou Lain Intelligent System Development Co., Ltd. strictly comply with national standards including “GB/T 20279-2024 Information Security Technology — Technical Specification for Network Security Isolation Products” and “GB/T 36466-2018 Information Security Technology — Technical Requirements and Test and Evaluation Methods for Network Gates.” They possess fully independent intellectual property rights and are fully compatible with domestic CPUs and operating systems, providing users across industries with highly reliable, high-security network boundary isolation solutions.
1.3 Product Core Value
1.3.1 Resolving the Core Contradiction Between “Security Isolation” and “Business Connectivity”
In traditional network architectures, high-security-level networks (such as classified internal networks and industrial control production networks) often adopt complete physical disconnection to ensure security, resulting in data exchange that relies on manual operations, which is inefficient and error-prone. If the network is directly connected, there is a significant risk of external attack penetration. The Network Gate perfectly resolves this contradiction: it maintains physical isolation strength while achieving automated, controllable data exchange, balancing both security and efficiency.
1.3.2 Meeting Mandatory Compliance Requirements
China’s “Cybersecurity Classified Protection 2.0,” “Classified Protection for Classified Information Systems,” “Industrial Control System Information Security Protection Guidelines,” and multiple other regulations and standards explicitly require the deployment of physical isolation equipment at critical information infrastructure and important network boundaries. In scenarios such as Level 3 and above classified protection systems, classified information systems, power dispatch systems, and government internal/external network boundaries, the Network Gate is mandatory equipment for compliance acceptance.
1.3.3 Resistance to Advanced Persistent Threats
Traditional firewalls are based on five-tuple access control and signature database matching, making them unable to handle featureless 0day vulnerability attacks and APT penetration. The Network Gate employs a triple mechanism — severing TCP/IP sessions, stripping original protocols, and deep content inspection — making it impossible for attackers to establish end-to-end network connections. Even if an external network host is compromised, malicious commands cannot be sent to the internal network side, dramatically enhancing the network boundary’s attack resistance capability.
1.4 Differences Between the Network Gate and Similar Security Devices
1.4.1 Differences Between the Network Gate and Firewall
| Comparison Dimension | Firewall | Network Gate |
|---|---|---|
| Isolation Level | Logical isolation (protocol-layer filtering) | Physical isolation (hardware-layer disconnection) |
| Working Principle | Forwards data packets, allows/blocks based on policies | Strips protocols, reassembles data, ferry transmission |
| TCP Sessions | Preserves end-to-end TCP connections | No end-to-end TCP connections exist |
| Security Strength | Medium-high; can be bypassed via protocol vulnerabilities | Extremely high; physically blocks penetration paths |
| Applicable Scenarios | General network boundary protection | High-security-level network boundary isolation |
| Performance | High; gigabit/10-gigabit line-speed forwarding | Medium-high; limited by ferry mechanism |
1.4.2 Differences Between the Network Gate and Physical Isolation Card
A physical isolation card is a terminal-level isolation solution that achieves single-machine internal/external network switching by installing dual hard drives and toggle switches on a single computer. It can only solve single-point isolation issues and cannot achieve automated data exchange between networks. The Network Gate is a network-level isolation solution deployed at network boundaries, supporting cross-domain data exchange across the entire network and suitable for large-scale network scenarios.
1.4.3 Differences Between the Network Gate and Optical Gate
The Optical Gate (unidirectional optical gate) is a sub-category of the Network Gate, employing fiber-optic unidirectional transmission technology that only supports one-way data flow. It offers higher security but is only suitable for unidirectional import scenarios. General-purpose bidirectional Network Gates support bidirectional controlled data exchange and are applicable to a broader range of scenarios.
1.5 Applicable Product Standards
This product’s design, production, and testing strictly comply with the following national and industry standards:
- GB/T 20279-2024 “Information Security Technology — Technical Specification for Network Security Isolation Products”
- GB/T 36466-2018 “Information Security Technology — Technical Requirements and Test and Evaluation Methods for Network Gates”
- GB/T 22239-2019 “Information Security Technology — Baseline for Classified Protection of Cybersecurity”
- BMB17-2006 “Technical Requirements for Classified Protection of Information Systems Involving State Secrets”
- GB/T 30976.1-2014 “Industrial Control System Information Security — Part 1: Evaluation Specification”
- YD/T 2708-2014 “Technical Requirements for Security Isolation and Information Exchange Systems in Telecommunications Networks”
Chapter 2 Product Composition

The LA-GAP series Network Gates adopt the standard “2+1” modular hardware architecture, consisting of three core modules — the internal network processing unit, external network processing unit, and dedicated isolation exchange unit — along with auxiliary components including power supply modules, cooling modules, management interface modules, and expansion function modules. All core modules adopt independent hardware design with no shared buses or shared memory, ensuring isolation strength at the physical level.
2.1 Internal Network Processing Unit (Internal Network Host)
The internal network processing unit is an independent host system on the high-security network side of the Network Gate. It adopts a domestic multi-core processor platform with a hardened, stripped-down secure operating system, responsible for interfacing with internal network business systems and executing internal-side protocol parsing, data encapsulation, and security policy matching functions.
2.1.1 Hardware Composition
- Main Control CPU: Uses domestic Phytium/Loongson multi-core processors with a clock speed of ≥2.0GHz, featuring independent computing and encryption processing capabilities with no backdoor risk.
- Memory Unit: Equipped with ECC-verified memory with capacities of 8GB–32GB optional, supporting real-time memory data clearing to prevent data residue leakage.
- Storage Unit: Uses industrial-grade SSD solid-state drives with capacities of 128GB–1TB optional, built-in write protection mechanism, and read-only mounting of system partitions to prevent malicious tampering.
- Business Interfaces: Configured with multiple gigabit/10-gigabit Ethernet electrical/optical ports for connection to internal network core switches, supporting electrical + optical Combo configurations for flexible adaptation to different network environments.
- Management Interface: Independent Console serial port and gigabit management electrical port, used only for local device management, physically separated from business interfaces.
2.1.2 Software Functions
- Internal-side Protocol Proxy and Termination: Terminates TCP/IP connections on the internal network side; does not directly forward any raw data packets.
- Data Reassembly and Encapsulation: Re-encapsulates raw data ferried from the isolation unit into standard protocol messages according to internal network security policies.
- Internal Security Policy Enforcement: Executes internal-side security rules including access control, address mapping, and user authentication.
- Logging and Auditing: Records all data exchange events on the internal network side and generates compliance audit logs.
2.2 External Network Processing Unit (External Network Host)
The external network processing unit is an independent host system on the low-security network side of the Network Gate. Its hardware architecture is symmetrical to the internal network processing unit and likewise runs an independent secure operating system. It is responsible for interfacing with external/third-party networks and executing external-side protocol parsing, content security inspection, and data stripping functions.
2.2.1 Hardware Composition
- Main Control CPU: Same specification domestic multi-core processor as the internal unit, ensuring matched processing capability on both sides.
- Memory Unit: Symmetrically configured ECC-verified memory matching the internal unit; buffer is automatically cleared after data ferry completion.
- Storage Unit: Independent industrial-grade SSD, storing only external-side system and temporary cache data, physically isolated from internal network storage.
- Business Interfaces: Symmetrical quantity of gigabit/10-gigabit business interfaces configured to match the internal unit, connecting to the external network.
- Expansion Interfaces: Support Bypass expansion module, automatically bypassing when the device is powered off or fails to ensure business availability.
2.2.2 Software Functions
- External Protocol Termination: Fully terminates network connections on the external side and strips all TCP/IP protocol headers.
- Deep Content Inspection: Integrates security engines including virus scanning, file filtering, sensitive information detection, and SQL injection protection, performing comprehensive security scanning on ferried data.
- Data Format Validation: Verifies data format legitimacy, blocking malformed packets and abnormal protocol messages.
- External Access Control: Enforces external-side policies including IP whitelists, port filtering, and access frequency limiting.
2.3 Dedicated Isolation Exchange Unit
The dedicated isolation exchange unit is the core component through which the Network Gate achieves physical isolation. Located between the internal network processing unit and external network processing unit, it is the only data path between the two side hosts and is the defining feature distinguishing the Network Gate from other security devices. This product adopts an FPGA-based dedicated isolation chip solution, with certain high-end models employing unidirectional optical channel solutions to completely eliminate bidirectional network connectivity risks.
2.3.1 Technology Types
- Dedicated Isolation Chip Type: Uses a self-developed FPGA isolation exchange chip with no internal TCP/IP protocol stack, supporting only private data transfer protocols, and achieving data ferry through a time-division multiplexing mechanism. The chip’s two sides connect respectively to the PCIe buses of the internal and external host, with no network-layer connectivity whatsoever.
- Unidirectional Optical Channel Type: Applied in unidirectional import series products, using a single fiber optic cable + unidirectional optical modules to achieve physical-level unidirectional transmission. The receiving side has no transmitting components and the transmitting side has no receiving components, ensuring from hardware physical characteristics that data can only flow in one direction with no reverse transmission channel.
2.3.2 Core Characteristics
- No Operating System, No Protocol Stack: The isolation unit executes pure hardware data transfer only; no software vulnerability risk exists.
- No Data Residue: Uses SRAM-based high-speed cache, with hardware-level clearing immediately after ferry completion; no data residue remains.
- Non-Programmability: Fixed data transfer logic; internal operating mechanisms cannot be modified remotely or locally.
- High Reliability: MTBF (Mean Time Between Failures) ≥100,000 hours, far exceeding general network devices.
2.4 Power Supply Module
The LA-GAP series Network Gates come standard with 1+1 redundant AC power supply modules supporting hot-swap. When a single power supply fails, the device seamlessly switches to the other supply without affecting business operations. High-end models support AC/DC dual-input power supplies, adapted for special power environments such as industrial scenarios and base stations.
The power supply module incorporates multiple protection mechanisms including overvoltage, overcurrent, undervoltage, short circuit, and overtemperature protection. Input voltage range supports AC 100~240V 50/60Hz wide-range adaptation, meeting power grid standards across different regions. Power conversion efficiency ≥92%, conforming to green energy-saving design requirements.
2.5 Cooling and Structural Module
- Chassis Structure: Standard 19-inch rack-mount chassis in 1U, 2U, and 4U height specifications, all constructed from high-quality galvanized steel sheet with excellent electromagnetic shielding performance, compliant with EMC electromagnetic compatibility standards.
- Cooling System: Intelligent temperature-controlled air-cooling solution with multiple high-reliability ball-bearing fans that automatically adjust speed based on internal temperature, balancing cooling efficiency with quiet operation. Air intakes are equipped with dust filters that can be periodically cleaned and replaced, ensuring long-term stable device operation.
- Front Panel: Configured with LED status indicators including power indicator, operation indicator, alarm indicator, and individual network port link status indicators, enabling operations personnel to intuitively view device operating status. High-end models feature an LCD display showing real-time CPU, memory, temperature, traffic, and other operating parameters.
- Rear Panel: Centralized arrangement of all business interfaces, management interfaces, power interfaces, grounding terminals, and expansion slots, with clear wiring layout for easy rack cabling management.
2.6 Expansion Function Modules
The LA-GAP series Network Gates support multiple optional expansion modules that users can select based on actual business requirements:
- Bypass Bypass Module: When the device is powered off, hung, or fails, corresponding business interfaces automatically hardware-bypass, preventing the Network Gate from becoming a network single point of failure.
- 10-Gigabit Optical Port Expansion Module: Expands multiple 10-gigabit SFP+ optical ports for high-bandwidth business scenarios.
- Serial Port Expansion Module: Expands multiple RS232/RS485 serial ports, supporting industrial serial protocol data ferry.
- Domestic Cryptographic Module: Built-in national cryptography algorithm chip supporting SM2/SM3/SM4 algorithms, meeting classified scenario encryption requirements.
- Log Storage Expansion Module: Built-in large-capacity storage hard drive for long-term local log retention.
Chapter 3 Product Classification

The LA-GAP series Network Gates form a complete product matrix classified by transmission direction, application scenario, hardware form factor, isolation technology, and performance grade, accommodating user requirements across different industries, scales, and security levels.
3.1 Classification by Data Transmission Direction
3.1.1 Bidirectional Network Gate (Safety Isolation and Information Exchange System)
The bidirectional Network Gate is the most common Network Gate product, supporting controlled bidirectional data exchange between internal and external networks. Both sides can actively initiate data transmission requests, and all data must pass security policy review before ferry passage.
- Core Features: Supports bidirectional business interaction, rich protocol support, and broad applicability.
- Typical Applications: Data exchange between government internal and external networks, business interaction between enterprise office and production networks, data synchronization between internal and external networks in financial institutions.
- Security Mechanism: Employs an asynchronous “request-ferry-response” processing mechanism; at no time do the two sides have direct connections, and all data exchange is fully auditable and controllable.
3.1.2 Unidirectional Network Gate (Safety Isolation and Information Unidirectional Import System)
The unidirectional Network Gate supports data transmission in only one direction — from the low-security network to the high-security network. At the physical level, no reverse data channel exists, providing higher security than bidirectional Network Gates. It is suitable for scenarios with extremely high data confidentiality requirements where outflow of data from high-security networks is prohibited.
- Core Features: Physical-level unidirectional transmission, zero reverse paths, eliminating the risk of high-security data flowing to lower-security networks.
- Typical Applications: Unidirectional import of internet data to classified internal networks, one-way upload of production network data to management networks, unidirectional aggregation of video surveillance data to police private networks.
- Technical Implementation: Employs unidirectional optical modules, hardware data diode, and similar technologies. The receiving end has no transmitting circuitry and the transmitting end has no receiving circuitry, ensuring absolutely unique data flow direction.
3.2 Classification by Application Scenario
3.2.1 General Government Affairs Type Network Gate
Customized and optimized for the government affairs industry, fully adapted to electronic government internal/external network exchange requirements, supporting typical government business including document exchange, information publishing, database synchronization, and email forwarding. Complies with the State Secrets Bureau’s electronic government confidentiality management requirements.
- Supports seamless integration with government OA and document exchange systems
- Built-in government sensitive information filtering rule library
- Supports government CA identity authentication integration
- Complies with classified protection evaluation requirements
3.2.2 Industrial Control Type Network Gate
Designed for industrial control system scenarios with deep support for various industrial control protocols, featuring industrial-grade characteristics including wide temperature range, interference resistance, and high reliability. Suitable for industrial control network boundary protection in electric power, petroleum, chemical, rail transit, and intelligent manufacturing industries.
- Deep parsing of dozens of industrial protocols including Modbus, OPC UA/DA, S7, DNP3, IEC104
- Supports industrial protocol instruction-level whitelist control
- Wide-temperature operating range: -40℃~70℃ (industrial-grade models)
- Supports high-availability deployments including dual-machine hot standby and ring network redundancy
- Low-power fanless design (embedded models)
3.2.3 Financial Industry Type Network Gate
Customized for the high-security, high-reliability, high-concurrency business characteristics of the financial industry, meeting the requirements of banks, securities, and insurance institutions for internal/external network data exchange and external organization access scenarios. Complies with financial industry regulatory requirements.
- Supports financial industry-specific protocol parsing
- Built-in financial sensitive data identification and desensitization functions
- Supports transaction-level fine-grained auditing
- Meets Level 3 and above classified protection compliance requirements
3.2.4 Video-Specific Type Network Gate
Optimized for video surveillance data cross-network transmission scenarios, supporting high-volume video stream efficient ferry, compatible with mainstream camera brands, NVRs, and video platforms, while ensuring security and controllability during video transmission.
- Supports video protocols including RTSP, ONVIF, GB/T 28181
- Supports video frame-level content inspection, preventing malicious code penetration through video streams
- High-bandwidth optimization, supporting concurrent transmission of over one hundred HD video streams per device
- Suitable for cross-network video transmission scenarios including Safe City, Skynet Project, and factory surveillance
3.3 Classification by Hardware Performance Grade
| Product Series | Throughput Performance | Interface Specification | Applicable Scenarios | Chassis Specification |
|---|---|---|---|---|
| LA-GAP-100 Series | 100-megabit grade, max throughput 100Mbps | 6× gigabit electrical ports | Small branch offices, district/county-level organizations, small projects | 1U rack-mount |
| LA-GAP-300 Series | Gigabit grade, max throughput 500Mbps | 8× gigabit electrical ports + 2× gigabit optical ports | Medium-sized enterprises, city-level organizations, medium-scale networks | 1U rack-mount |
| LA-GAP-500 Series | Gigabit grade, max throughput 1000Mbps | 12× gigabit electrical ports + 4× gigabit optical ports | Large enterprises, provincial-level organizations, core network boundaries | 2U rack-mount |
| LA-GAP-700 Series | 10-gigabit grade, max throughput 5Gbps | 8× gigabit electrical ports + 4× 10-gigabit optical ports | Data centers, large government platforms, high-bandwidth scenarios | 2U rack-mount |
| LA-GAP-900 Series | 10-gigabit grade, max throughput 20Gbps | 16× 10-gigabit optical ports + 8× gigabit electrical ports | Ultra-large data centers, provincial backbone nodes, carrier scenarios | 4U rack-mount |
3.4 Classification by Isolation Technology Route
3.4.1 Chip Ferry Type Network Gate
Uses dedicated FPGA isolation chips for data ferry. Highly mature technology, stable performance, and support for bidirectional data exchange. This is the mainstream product form in the current market, suitable for the vast majority of general isolation scenarios.
3.4.2 Fiber Optic Isolation Type Network Gate
Uses optical fiber as the isolation medium, leveraging the unidirectional transmission characteristics of light to achieve physical isolation. Divided into two categories: unidirectional optical gate and bidirectional optical gate. Unidirectional optical gates offer the highest security; bidirectional optical gates achieve bidirectional data transmission through two independent unidirectional optical paths. Electromagnetic isolation performance is superior to chip-type, suitable for strong electromagnetic interference and high-confidentiality scenarios.
3.4.3 Fully Domesticated Type Network Gate
A full-stack domesticated Network Gate product fully adapted to domestic CPUs, operating systems, databases, and middleware, achieving complete domestic self-controllability from hardware to software. Meets the localization substitution requirements of party and government organs and critical infrastructure sectors.
- Adapted CPUs: Phytium, Loongson, Kunpeng, Hygon, Sunway
- Adapted Operating Systems: Kylin, UOS, EulerOS
- Adapted Databases: DM (Dameng), KingbaseES, GBase, OceanBase
Chapter 4 Product Checklist
4.1 Standard Configuration Checklist
Each LA-GAP series Network Gate ships from the factory with the following standard configuration items. Users should verify items against the checklist upon receipt and contact the manufacturer promptly if anything is missing.
| No. | Item Name | Quantity | Remarks |
|---|---|---|---|
| 1 | LA-GAP series Network Gate host | 1 unit | Specific model per purchase order |
| 2 | AC power cable | 2 pcs | 10A national standard three-pin power cable, redundant power configuration |
| 3 | Serial configuration cable | 1 pc | RJ45 to RS232 Console cable, for initial configuration |
| 4 | Rack mounting ears | 1 pair | 19-inch standard rack mounting brackets |
| 5 | Mounting screw kit | 1 pack | Includes rack mounting screws, nuts, and washers |
| 6 | Product certificate of conformity | 1 copy | Factory inspection qualification certificate |
| 7 | Product warranty card | 1 copy | Warranty service credential |
| 8 | This installation and commissioning manual | 1 copy | Paper version; electronic version available for download from official website |
| 9 | Packing list | 1 copy | Shipping configuration verification sheet |
4.2 Optional Accessory Checklist
The following are optional accessories that users may purchase separately based on actual project requirements:
| No. | Accessory Name | Applicable Models | Function Description |
|---|---|---|---|
| 1 | 10-gigabit SFP+ optical module | 500 series and above | 10-gigabit fiber interface module, single-mode/multi-mode selectable |
| 2 | Gigabit SFP optical module | All series | Gigabit fiber interface module, single-mode/multi-mode selectable |
| 3 | Bypass bypass module | 300 series and above | Hardware bypass function, automatic pass-through on failure |
| 4 | National cryptography encryption card | All series | Built-in SM2/SM3/SM4 national cryptography algorithm chip |
| 5 | DC power supply module | Industrial-grade models | 48V DC power input, adapted for industrial scenarios |
| 6 | Redundant power supply module | 100 series | 100 series comes standard with single power supply; second redundant supply can be purchased |
| 7 | Dust filter kit | All series | Spare air intake dust filters for periodic replacement |
| 8 | Serial server module | Industrial-type Network Gates | Expands RS485/RS232 serial port quantity |
4.3 Documentation Description
- Product Certificate of Conformity: Contains product model, factory serial number, inspection date, and inspector’s signature, certifying that the product meets quality standards at the time of shipment.
- Product Warranty Card: Records product information and purchase information, serving as the sole credential for warranty service. Users should keep it in a safe place.
- Installation and Commissioning Manual: This document, containing complete guidance for product installation, wiring, commissioning, operations and maintenance, and troubleshooting.
- Packing List: Detailed listing of all items packed with this device for receipt verification.
4.4 Receiving and Acceptance Precautions
After receiving the device, first check whether the outer packaging is intact and free of severe impacts, compression, or water immersion marks. If the outer packaging is damaged, refuse delivery on the spot and contact the logistics provider and manufacturer.
After opening the box, verify the quantity and models of all items against the packing list, and proceed with subsequent installation only after confirmation.
Check the device exterior for physical damage such as paint peeling, deformation, or interface damage. If abnormalities are found, contact the manufacturer’s after-sales department within 24 hours of receipt.
Record the device’s factory serial number (located on the nameplate at the rear of the device). This serial number is the device’s unique identity identifier and must be provided for subsequent technical support and warranty service.
Chapter 5 Product Principles
5.1 Core Architecture Principle: 2+1 Physical Isolation Architecture
The LA-GAP series Network Gates adopt the industry’s most mature “2+1” physical isolation architecture, consisting of two independent hosts + one dedicated isolation unit. The internal network host and external network host are two completely independent computer systems, each with its own independent CPU, memory, storage, and operating system. No network connection, bus sharing, or memory sharing exists between them — the only data path is the dedicated isolation exchange unit in the middle.
This architecture completely severs TCP/IP connections between internal and external networks at the physical level, rendering traditional network attack methods that rely on protocol stacks and session connections completely ineffective. Even if an attacker fully compromises the external network host, they cannot send data packets to the internal network side through network protocols — they can only ferry limited, strictly reviewed pure data through the isolation unit, dramatically raising the attack threshold and security strength.
5.2 Data Ferry Working Principle
Data ferry is the core mechanism by which the Network Gate achieves cross-network data exchange. Its essence is an asynchronous processing flow of “store-verify-forward,” similar to how a canal lock operates: a vessel enters the lock chamber from the upstream channel, the upstream gate closes, the downstream gate opens, and the vessel proceeds into the downstream channel. Throughout the process, the upstream and downstream channels never directly connect. The Network Gate’s data ferry process is analogous, divided into three core stages.
5.2.1 Stage One: Protocol Stripping and Data Reception
When the external network side has data to transmit to the internal network, the external processing unit first receives the complete network data packet from the external network, then disassembles the packet layer by layer:
- Strip physical layer and data link layer frame headers;
- Strip IP layer, TCP/UDP layer protocol headers;
- Strip application layer protocol headers, extracting the pure business data payload;
- Perform format validation and integrity verification on the extracted pure data.
Through this process, the original network data packet is disassembled into raw data with no protocol characteristics whatsoever. All protocol fields and option fields that could carry attack code are completely removed, fundamentally eliminating the possibility of protocol vulnerability attacks.
5.2.2 Stage Two: Security Review and Ferry Transmission
The stripped raw data does not enter the internal network directly. Instead, it is first sent to the security inspection engine for deep content review, including:
- Virus and Trojan Scanning: Signature-based + heuristic detection, scanning file-type viruses, macro viruses, and malicious scripts;
- File Type Validation: Identifying true file formats to prevent malicious files with forged extensions;
- Sensitive Content Detection: Detecting whether data contains classified information or prohibited keywords;
- Data Whitelist Matching: Verifying whether data conforms to predefined business data format specifications;
- Malicious Code Sandbox Detection: Performing sandbox behavior analysis on executable files and script files.
After review passes, the external processing unit writes the data to the isolation exchange unit’s transmit buffer. The isolation unit copies the data from the external-side buffer to the internal-side buffer through hardware transfer, then immediately clears the external-side buffer upon completion. The entire ferry process is controlled by pure hardware logic, running no operating system, with no software vulnerabilities.
5.2.3 Stage Three: Protocol Reconstruction and Data Transmission
When the internal processing unit detects data in the isolation unit’s internal-side buffer, it reads the data content and, according to internal-side security policies and business configuration, re-encapsulates the pure data with new application layer protocol headers, transport layer protocol headers, network layer protocol headers, and data link layer frame headers, generating entirely new network data packets and transmitting them to the internal network destination address.
Throughout this process, the data packets received by the internal network are brand-new messages regenerated by the Network Gate, completely unrelated to the original external network packets. Attackers cannot perform session tracking or attacks using sequence numbers, timestamps, or similar methods.
5.3 Unidirectional Network Gate Working Principle
The unidirectional Network Gate further restricts data transmission direction at the hardware level based on the ferry mechanism. Taking the unidirectional optical gate as an example, its isolation unit consists of a set of unidirectional optical transmit modules and a set of unidirectional optical receive modules:
- Low-security side (transmit end): Contains only optical transmit components with no optical receive components — can only send data and cannot receive any reverse signals;
- High-security side (receive end): Contains only optical receive components with no optical transmit components — can only receive data and cannot send any signals outward;
- Connected by a single optical fiber in between: Optical signals can only propagate from the transmit end to the receive end, with no physical transmission path in the reverse direction.
This physical characteristic determines that data can only flow from the low-security network to the high-security network. Reverse data transmission is absolutely impossible. Even if the high-security side host is fully compromised, it cannot send any data outward through the optical gate, fundamentally eliminating the risk of “high-security data leaking to lower-security networks.”
5.4 Protocol Proxy Principle
The Network Gate’s support for various application layer protocols is achieved through protocol proxy technology. The Network Gate does not directly forward protocol messages. Instead, corresponding protocol proxy services run on both side hosts:
- The external side runs a protocol server-side proxy, simulating a real business server to establish connections with external clients and receive client requests;
- Request data is delivered to the internal side after stripping, review, and ferry;
- The internal side runs a protocol client-side proxy, simulating a real client to establish connections with internal business servers and forward request content;
- Server response data executes the same flow in reverse, ultimately returning to the external client.
Taking the HTTP protocol as an example: when an external user accesses an internal Web server, they first establish a TCP connection with the HTTP proxy on the external side of the Network Gate. The gate’s proxy extracts URL, parameters, and other request content, and after security inspection, ferries it to the internal side. The internal-side HTTP proxy then establishes a connection with the real Web server, sends the request, obtains the response, and ferries it back to the external side, ultimately returning it to the user. Throughout the entire process, no real TCP connection exists between internal and external networks — all connections terminate at the two sides of the Network Gate.
5.5 Security Enhancement Principles
5.5.1 Kernel-Level Security Hardening
Both the internal and external host operating systems undergo deep security hardening and reduction. All unnecessary system services, ports, and commands are removed, all non-essential kernel modules are disabled, and a Mandatory Access Control (MAC) mechanism is employed to restrict process privileges. Even if an attacker breaches the application layer, they cannot gain system control.
5.5.2 Dual Independent Security Domains
The internal unit and external unit belong to two completely independent security domains. Management accounts, passwords, and certificates are independently configured and not interchangeable. External-side administrators cannot log in to the internal unit, and internal-side administrators cannot log in to the external unit, achieving physical isolation of management privileges.
5.5.3 Zero Data Residue Mechanism
- The isolation unit’s cache uses SRAM static memory that loses data upon power-off, with hardware automatic clearing after ferry completion;
- Host memory buffers employ real-time clearing mechanisms, with processed data immediately removed from memory;
- Temporary storage files use a single-read-write mechanism, with files immediately deleted and subjected to disk overwriting after reading to prevent data recovery.
Chapter 6 Product Technical Specifications
6.1 Hardware Architecture Specifications
| Parameter Item | LA-GAP-100 | LA-GAP-300 | LA-GAP-500 | LA-GAP-700 | LA-GAP-900 |
|---|---|---|---|---|---|
| System Architecture | 2+1 physical isolation architecture | 2+1 physical isolation architecture | 2+1 physical isolation architecture | 2+1 physical isolation architecture | 2+1 physical isolation architecture |
| Processor | Domestic 4-core processor | Domestic 8-core processor | Domestic 16-core processor | Domestic 32-core processor | Domestic 64-core processor |
| Memory Capacity | 8GB ECC | 16GB ECC | 32GB ECC | 64GB ECC | 128GB ECC |
| System Storage | 128GB SSD | 256GB SSD | 512GB SSD | 1TB SSD | 2TB SSD |
| Isolation Unit | FPGA dedicated isolation chip | FPGA dedicated isolation chip | FPGA dedicated isolation chip | FPGA + dual optical channel | Multiple independent optical channels |
| Chassis Specification | 19-inch 1U rack-mount | 19-inch 1U rack-mount | 19-inch 2U rack-mount | 19-inch 2U rack-mount | 19-inch 4U rack-mount |
| Power Configuration | Single power supply (redundant optional) | 1+1 redundant power supply | 1+1 redundant power supply | 1+1 redundant power supply | 2+2 redundant power supply |
| Power Input | AC 100-240V | AC 100-240V | AC 100-240V | AC 100-240V | AC 100-240V |
| Maximum Power | 80W | 120W | 200W | 350W | 600W |
6.2 Business Interface Specifications
| Parameter Item | LA-GAP-100 | LA-GAP-300 | LA-GAP-500 | LA-GAP-700 | LA-GAP-900 |
|---|---|---|---|---|---|
| Gigabit Electrical Ports | 6 (3 per side) | 8 (4 per side) | 12 (6 per side) | 8 (4 per side) | 8 (4 per side) |
| Gigabit Optical Ports | 0 | 2 (1 per side) | 4 (2 per side) | 0 | 0 |
| 10-Gigabit Optical Ports | 0 | 0 | 0 | 4 (2 per side) | 16 (8 per side) |
| Console Ports | 1 (RJ45) | 1 (RJ45) | 1 (RJ45) | 1 (RJ45) | 2 (1 per side) |
| Management Ports | 1 gigabit electrical port | 2 gigabit electrical ports (1 per side) | 2 gigabit electrical ports (1 per side) | 2 gigabit electrical ports (1 per side) | 4 gigabit electrical ports (2 per side) |
| USB Ports | 2 (front) | 2 (front) | 4 (2 front, 2 rear) | 4 (2 front, 2 rear) | 4 (2 front, 2 rear) |
| Interface Characteristics | Supports 10/100/1000M auto-negotiation, full duplex, MDI/MDIX auto-crossover | Same as left | Same as left | 10G ports support 10G/1G auto-negotiation | Same as left |
6.3 Performance Specifications
| Parameter Item | LA-GAP-100 | LA-GAP-300 | LA-GAP-500 | LA-GAP-700 | LA-GAP-900 |
|---|---|---|---|---|---|
| System Throughput | ≥100Mbps | ≥500Mbps | ≥1000Mbps | ≥5Gbps | ≥20Gbps |
| Maximum Concurrent Connections | ≥5,000 | ≥20,000 | ≥50,000 | ≥200,000 | ≥500,000 |
| New Connections per Second | ≥500 | ≥2,000 | ≥5,000 | ≥20,000 | ≥50,000 |
| File Transfer Rate | ≥8MB/s | ≥40MB/s | ≥80MB/s | ≥400MB/s | ≥1500MB/s |
| Database Synchronization Rate | ≥500 records/sec | ≥2,000 records/sec | ≥5,000 records/sec | ≥20,000 records/sec | ≥50,000 records/sec |
| Hardware Switching Latency | ≤5ms | ≤5ms | ≤3ms | ≤1ms | ≤1ms |
| Maximum Policy Rule Count | ≥1,000 rules | ≥5,000 rules | ≥10,000 rules | ≥50,000 rules | ≥100,000 rules |
| Log Storage Capacity | ≥10 million records | ≥50 million records | ≥100 million records | ≥500 million records | ≥1 billion records |
6.4 Security Function Specifications
| Function Category | Detailed Specification Indicators |
|---|---|
| Protocol Support | Supports 30+ application layer protocols including HTTP/HTTPS, FTP/SFTP, SMTP/POP3, databases (Oracle/MySQL/SQL Server/DM/KingbaseES), file sharing, industrial protocols (Modbus/OPC/S7, etc.), video protocols |
| Access Control | Supports multi-dimensional access control based on IP, port, user, time, and content; supports whitelist/blacklist modes; supports fine-grained URL filtering |
| Content Security | Built-in virus scanning engine with regularly updated virus databases; supports file type identification and filtering; supports sensitive keyword detection; supports SQL injection and XSS attack protection; supports macro virus detection and blocking |
| Identity Authentication | Supports local username/password authentication; supports LDAP/AD domain authentication; supports digital certificate authentication; supports national cryptography SM2 identity authentication |
| Security Auditing | Records all data exchange logs including time, source IP, destination IP, operation type, data size, and processing result; log retention ≥6 months; supports log query, statistics, and export |
| High Availability | Supports dual-machine hot standby (active-standby/active-active modes); supports link aggregation; supports Bypass hardware bypass; supports automatic failover with switching time <1s |
| Management Security | Supports three-administrator separation of duties (system administrator, security administrator, audit administrator); supports fine-grained operation permission assignment; supports login IP whitelist; supports full audit of operation logs |
6.5 Environmental and Reliability Specifications
| Parameter Item | Standard Models | Industrial-Grade Models |
|---|---|---|
| Operating Temperature | 0℃~45℃ | -40℃~70℃ |
| Storage Temperature | -20℃~70℃ | -40℃~85℃ |
| Operating Humidity | 10%~90%, non-condensing | 5%~95%, non-condensing |
| Mean Time Between Failures (MTBF) | ≥50,000 hours | ≥100,000 hours |
| Electromagnetic Compatibility | Compliant with GB/T 17626 industrial-grade standard | Compliant with GB/T 17626 severity level 4 |
| Protection Rating | Front panel IP30 | Full unit IP40 |
| Seismic Performance | Compliant with GB/T 9813 General Specification for Computers | Compliant with GJB 150 Military Equipment Environmental Test Standard |
6.6 Compliance Certification Specifications
This product has passed inspection and certification by the following national authoritative organizations:
- National Secrecy Science and Technology Evaluation Center: Classified Information System Product Testing Certificate
- Ministry of Public Security Information Security Product Testing Center: Computer Information System Security Special Product Sales License
- China Cybersecurity Review Technology and Certification Center: Information Security Product Certification (CCC Certification)
- State Grid Corporation of China: Power-Specific Safety Product Network Access License
- Ministry of Industry and Information Technology: Telecommunications Equipment Network Access License (carrier models)
- State Cryptography Administration: Commercial Cryptography Product Certification (models with national cryptography)
Chapter 7 Product Functions and Features
7.1 Core Security Functions
7.1.1 Physical-Level Network Isolation
Employs a 2+1 dual-host physical isolation architecture with no network-layer or link-layer direct connections between internal and external networks. Isolation strength reaches the physical isolation level, far exceeding logical isolation devices such as firewalls and IPS, effectively resisting the vast majority of network attack methods.
7.1.2 Deep Protocol Parsing and Stripping
Supports deep parsing of over 30 mainstream application layer protocols, completely stripping the TCP/IP protocol stack and transmitting only pure business data, completely eliminating attack paths based on protocol vulnerabilities. All protocol parsing uses self-developed engines without reliance on open-source components, avoiding security risks introduced by open-source vulnerabilities.
7.1.3 Multi-Dimensional Content Security Inspection
Integrates multiple security inspection engines for comprehensive security review of ferried data:
- Virus Scanning Engine: Uses signature-based + heuristic dual detection technology, capable of detecting known viruses and unknown polymorphic viruses, supporting Office macro virus, script virus, and embedded virus detection.
- File Format Validation Engine: Identifies true file types based on file magic numbers, blocking malicious files disguised through extension name modification, supporting identification of over one hundred file formats.
- Sensitive Information Detection Engine: Built-in regular expression matching engine, supporting custom sensitive keywords and regex rules, detecting and blocking the transmission of classified information, personal privacy, and prohibited content.
- Application Layer Attack Protection Engine: Identifies and blocks common Web attacks including SQL injection, XSS cross-site scripting, command injection, and path traversal, protecting internal business system security.
7.1.4 Fine-Grained Access Control
Provides seven-layer access control capability combining five-tuple + application layer + content:
- Supports basic access control based on source IP, destination IP, source port, destination port, and protocol;
- Supports identity-based permission control based on users and user groups;
- Supports time-based access policies, configurable for different rules on workdays vs. non-working hours;
- Supports application-layer fine-grained control based on URL, file type, and command words;
- Supports whitelist mode, allowing only preset legitimate data to pass with all unknown traffic denied by default.
7.1.5 Complete Security Auditing
Possesses comprehensive log auditing functionality, recording all data exchange events and management operation events:
- Data Exchange Logs: Record source address, destination address, transmission time, data size, protocol type, processing result, and matched policy for each data record;
- Management Operation Logs: Record all operations including administrator login, configuration modification, system upgrade, and policy changes, supporting operation traceability;
- System Operation Logs: Record CPU, memory, disk, interface status, alarm events, and other system operation information;
- Logs support local storage, remote Syslog transmission, log export, and statistical report generation, meeting compliance audit requirements.
Chapter 7 Product Functions and Features
7.1 System Architecture
The LA-GAP series security gateway adopts a “2+1” system architecture, consisting of an external network host unit, an internal network host unit, and an isolation switch unit. The external network host unit handles external network data communication, the internal network host unit handles internal network data communication, and the isolation switch unit is the data exchange bridge between the two, physically disconnecting the internal and external networks through a dedicated hardware switch mechanism.
The design of the isolation switch unit exclusively employs self-developed dedicated security isolation chips, supporting high-speed data exchange while ensuring that no logical or physical connection exists between the internal and external network units. Both the internal and external network units run independently of each other’s network protocols and services.
7.2 Business Functions
7.2.1 Rich Protocol Proxy
Built-in rich protocol proxy modules allow rapid deployment without modifying the user’s existing business systems:
- Web Access Proxy: Supports HTTP/HTTPS protocol proxy for cross-network web page access, with URL filtering, content replacement, and Cookie security hardening.
- File Transfer Proxy: Supports file transfer protocols such as FTP/SFTP/file sharing, with file type filtering, file size limits, and virus scanning.
- Email Proxy: Supports SMTP/POP3/IMAP mail protocols, with email content filtering, attachment scanning, and anti-spam capabilities.
- Database Synchronization Proxy: Supports mainstream databases such as Oracle, MySQL, SQL Server, PostgreSQL, DM (Dameng), and KingbaseES (People’s Jincang), with support for trigger-based and log-based bidirectional data synchronization, as well as table-level and field-level fine-grained control.
- Industrial Protocol Proxy: Supports dozens of industrial control protocols including Modbus RTU/TCP, OPC UA/DA, S7, IEC104, and DNP3, with instruction-level whitelist control.
- Video Protocol Proxy: Supports video protocols such as GB/T 28181, RTSP, and ONVIF for cross-network video stream transmission and PTZ control.
7.2.2 Custom Data Exchange
In addition to standard protocols, the system supports user-defined data exchange rules to accommodate various proprietary protocols and customized business systems:
- Supports port-based generic TCP/UDP data ferry;
- Supports custom protocol format parsing rules;
- Supports file-based customized data exchange;
- Provides secondary development interfaces for deep integration with user business systems.
7.2.3 High Availability Deployment Support
Comprehensive high-availability features to ensure business continuity:
- Dual-Machine Hot Standby: Supports Active/Standby and Active/Active modes. When the primary device fails, the standby device automatically takes over with a switchover time of less than 1 second, ensuring zero business interruption.
- Link Aggregation: Supports aggregating multiple business interfaces into logical links, increasing bandwidth while achieving link redundancy. Failure of a single link does not affect business operations.
- Hardware Bypass: Optional Bypass module that automatically provides hardware passthrough for corresponding business interfaces during power failure, system crash, or device malfunction, preventing the gateway from becoming a single point of network failure.
- Load Balancing: High-end models support multi-device cluster deployment, with automatic traffic load sharing to improve overall throughput.
7.3 Management and O&M Functions
7.3.1 Multiple Management Methods
- Web Management: Provides a graphical web management interface with HTTPS encrypted access. Configuration is intuitive and convenient — no professional command-line knowledge required.
- Command Line Management: Supports Console serial port and SSH command-line management, meeting the preferences of professional O&M personnel.
- Centralized Management: Supports integration with security management platforms for unified monitoring, configuration distribution, and log aggregation of multiple gateway devices.
- Local Management: Management interfaces are physically separated from business interfaces, supporting local independent management network deployment to enhance management security.
7.3.2 Separation of Powers Management
Compliant with national information security standards, the system includes three administrator roles — System Administrator, Security Administrator, and Audit Administrator — with independent and mutually constraining permissions:
| Role | Responsibilities |
|---|---|
| System Administrator | Responsible for system-level operations including device system configuration, network configuration, and version upgrades |
| Security Administrator | Responsible for security-related operations including security policy configuration, rule management, and user permission management |
| Audit Administrator | Responsible for log auditing, report generation, and operation record viewing. Cannot modify any configuration |
7.3.3 Intelligent Monitoring and Alerting
- Real-time monitoring of device CPU, memory, disk, temperature, fan speed, and other operational status;
- Real-time monitoring of business metrics for each interface including traffic, connection count, and throughput rate;
- Support for multi-level alert threshold configuration with automatic alerting on abnormal conditions;
- Support for multiple alert methods: email alerts, SNMP alerts, Syslog alerts, and audible/visual alerts.
7.3.4 Convenient Configuration and Maintenance
- Supports configuration file backup and restore with one-click export/import;
- Supports online system firmware upgrades without business interruption (in dual-machine deployment);
- Supports diagnostic tools with built-in ping, traceroute, packet capture, and other network diagnostic functions;
- Supports configuration wizard to guide new users through basic configuration quickly.
7.4 Core Product Features
7.4.1 High Security, Autonomous and Controllable
- The full product line uses domestic processors and operating systems with completely self-developed core technologies, eliminating supply chain risks;
- Full-stack support for domestic cryptographic algorithms (SM series), meeting encryption requirements for classified scenarios;
- Passed multiple authoritative national security certifications, ensuring regulatory compliance.
7.4.2 High Performance, Stable and Reliable
- Dedicated hardware isolation chips provide low data-ferry latency and high throughput;
- Redundant power supplies, redundant fans, and hot-swappable design for high hardware reliability;
- Industrial-grade hardware design adaptable to demanding operating environments;
- Proven stability through extensive industry project deployment.
7.4.3 Easy Deployment, Rapid Go-Live
- Transparent proxy deployment mode that does not require modifying existing network topology or business systems;
- Built-in rich industry scenario configuration templates for rapid application;
- Graphical configuration interface with simple operations, lowering the O&M barrier.
7.4.4 Flexible Adaptation to All Scenarios
- Complete product matrix covering from 100M to 10G, adapting to networks of different scales;
- Multiple product categories including General-Purpose, Industrial, Video, and Unidirectional types for different industry scenarios;
- Modular design with on-demand function selection to protect user investment.
Chapter 8 Product Application Scenarios
8.1 Government Industry Applications
8.1.1 Government Internal/External Network Boundary Isolation
Government internal networks and external networks are the two major network systems of e-government. National requirements mandate physical isolation between them, yet daily government operations involve substantial cross-network data exchange needs such as official document transmission, information publishing, and data sharing.
Deployment Solution: Deploy bidirectional security gateways at the boundary between the government internal and external networks. Through proxy modules such as file exchange, database synchronization, and Web access, achieve controlled data exchange between the two networks. All cross-network data undergoes virus scanning, sensitive information detection, and compliance review, ensuring secure and compliant data exchange while meeting graded protection (MLPS) evaluation requirements.
8.1.2 One-Way Import of Internet Data to Government Internal Network
Government departments need to obtain public information, public opinion data, and materials submitted by citizens from the Internet, but the government internal network is prohibited from directly connecting to the Internet, and internal network data is also prohibited from flowing to the Internet.
Deployment Solution: Deploy unidirectional gateways to achieve one-way import of Internet data into the government internal network. The external network side collects Internet data, performs security cleansing, and then ferries the data to the internal network through a one-way channel. The physical layer eliminates any reverse data outflow, satisfying both the internal network’s need to acquire external data and ensuring internal network security.
8.1.3 Dedicated Network Data Exchange Between Departments
Different government departments operate their own dedicated business networks with varying security levels. They need to share business data across networks without directly connecting the networks.
Deployment Solution: Deploy security gateways at the boundaries of each department’s dedicated network. Through a secure data exchange platform, achieve cross-departmental data sharing. Each department only opens authorized data interfaces, and all data exchange is auditable and traceable, achieving data sharing while ensuring the independence and security of each department’s network.
8.2 Energy and Electric Power Industry Applications
8.2.1 Power Dispatch Network and Management Information Network Isolation
The power dispatch network is the core production network of the power system with an extremely high security level. Per power industry regulations, it must be physically isolated from the management information network. However, production data must be uploaded to the management network for statistical analysis, and management commands must also be sent down to the production network.
Deployment Solution: Deploy industrial-type security gateways at the boundary between the dispatch network and management network, supporting power-specific protocols such as IEC104 and DNP3 to achieve secure upload of power monitoring data and secure delivery of control commands. The gateway performs instruction-level whitelist control on industrial protocols, allowing only preconfigured legitimate instructions through and blocking illegal control commands, thereby safeguarding power grid operation security.
8.2.2 Oil and Gas Field Industrial Control Network Isolation
The SCADA and DCS systems at oil and gas production sites belong to industrial control networks that face attack risks from office networks and the Internet.
Deployment Solution: Deploy industrial-grade security gateways at the boundary between the industrial control network and office network to prevent security risks from the office network penetrating into the production network. Support data ferry for industrial protocols such as Modbus and OPC to enable production data collection and remote monitoring, while blocking viruses, Trojans, and ransomware from spreading from the office network to the industrial control network.
8.2.3 New Energy Power Station Centralized Control Scenario
New energy power stations are widely distributed across regions. Data from each station needs to be aggregated to a provincial-level centralized control center. Station-side network security defenses are often weak and can easily become attack entry points.
Deployment Solution: Deploy industrial security gateways at each power station side, physically isolating the station’s internal industrial control network from the external transmission network. All data uploaded to the centralized control center passes through security review at the gateway, preventing external attacks from penetrating back into the station’s industrial control system through the centralized control link.
8.3 Financial Industry Applications
8.3.1 Bank Internal/External Network Data Exchange
Banks require strict isolation between internal business networks and the Internet, but services such as online banking, mobile banking, and third-party payment require cross-network data interaction.
Deployment Solution: Deploy security gateways between the bank’s DMZ zone and core business network to achieve secure data exchange between Internet-side service requests and core business systems. The gateway performs deep inspection of transaction data to prevent illegal transaction commands and attack packets from entering core systems, while also desensitizing sensitive information in returned data to prevent customer information leakage.
8.3.2 One-Way Import of Market Data for Securities Institutions
Securities trading internal networks have extremely high security levels. They need to access real-time market data from external sources, but absolutely prohibit any data flowing out of the internal network.
Deployment Solution: Deploy unidirectional gateways to import market data from external market data providers one-way into the securities trading internal network. The physical layer ensures there is no reverse data channel, completely eliminating the risk of trading data or customer data leakage.
8.4 Industrial Manufacturing Industry Applications
8.4.1 Smart Manufacturing Factory IT/OT Network Isolation
The convergence trend between IT office networks and OT production networks in smart manufacturing enterprises is evident. However, OT network equipment is often legacy and lacks security protection, making it vulnerable to viruses and attacks originating from the IT side.
Deployment Solution: Deploy industrial security gateways at the boundary between IT and OT networks to achieve physical isolation between the two networks. Support data exchange between MES systems and production equipment, and data synchronization between ERP and workshop systems, while blocking ransomware and worm viruses from spreading from the office network to the production network, ensuring production safety.
8.4.2 Industrial Cloud Platform Data Access
Enterprises upload production data to industrial cloud platforms for big data analytics and remote maintenance, requiring protection of the factory’s internal network security.
Deployment Solution: Deploy security gateways between the factory egress and the industrial cloud. Only allow authorized production data to be uploaded to the cloud, prohibit the cloud from actively accessing the factory’s internal network, and prevent cloud-side security risks from reverse-penetrating into the factory’s internal network.
8.5 Healthcare Industry Applications
8.5.1 Hospital Internal Network and Internet Isolation
Hospital internal information systems (HIS, LIS, PACS, etc.) carry large amounts of patient privacy data and cannot be directly connected to the Internet. However, Internet-based convenience services such as appointment booking, registration, and report query require interaction with the internal network.
Deployment Solution: Deploy security gateways at the boundary between the hospital internal network and the Internet to achieve secure data exchange between Internet service requests and internal business systems. The gateway desensitizes patient information to prevent privacy data leakage, while blocking attacks from the Internet side, meeting healthcare industry compliance requirements for classified protection (MLPS).
8.5.2 Cross-Regional Healthcare Data Sharing
Medical alliances and regional healthcare platforms need to enable data sharing between different hospitals, but each hospital’s internal network is independent and cannot be directly interconnected.
Deployment Solution: Deploy security gateways between each hospital network and the regional healthcare platform. Achieve cross-hospital data sharing through unified data exchange standards. All patient data transmission undergoes encryption and security review, ensuring healthcare data security.
8.6 Military and Classified Scenario Applications
8.6.1 Classified Network and Non-Classified Network Isolation
Military units and classified institutions must strictly physically isolate classified internal networks from non-classified office networks. There is a need to import non-classified data into the classified network.
Deployment Solution: Deploy unidirectional import gateways that only allow one-way import of data from the non-classified network to the classified network. The physical absence of a reverse transmission channel completely eliminates the risk of classified information leakage. All imported data undergoes virus scanning and classified information detection, in compliance with national confidentiality standards.
8.6.2 Data Exchange Between Networks of Different Classification Levels
Controlled data exchange is required between networks of different classification levels (e.g., Top Secret, Secret) within the same organization, strictly adhering to the prohibition of transmitting data from higher to lower classification levels.
Deployment Solution: Deploy unidirectional gateways between networks of different classification levels. Data can only flow from lower-level classified networks to higher-level classified networks. Reverse transmission is prohibited, ensuring compliance with classification management requirements of graded protection.
8.7 Security and Video Surveillance Applications
8.7.1 Safe City Video Cross-Network Transmission
Safe City video surveillance data is distributed across public security video private networks and social surveillance networks. Social-side video needs to be aggregated to the public security private network, but direct connectivity between the public security private network and social networks is prohibited.
Deployment Solution: Deploy video-specific security gateways that support the GB/T 28181 national standard protocol, enabling one-way transmission of social-side video streams to the public security private network, while also supporting secure ferry of PTZ control commands. The gateway performs frame-level security inspection on video streams to prevent malicious code from penetrating the public security private network through video streams.
8.7.2 Factory Surveillance Cross-Network Viewing
Enterprise factory surveillance is deployed on the production private network. Office network personnel need to view surveillance feeds, but the office network is not permitted to directly access the surveillance private network.
Deployment Solution: Deploy security gateways between the surveillance private network and office network with video proxy functionality configured. Office network users can view surveillance feeds after authorization, while security risks from the office network are isolated from spreading to the surveillance private network.
Chapter 9 Product Installation
9.1 Pre-Installation Preparation
9.1.1 Environment Inspection
Before installation, the equipment installation environment must be inspected to ensure it meets equipment operational requirements, preventing equipment failures or shortened service life due to environmental issues.
Server Room Environment Requirements
| Parameter | Requirement |
|---|---|
| Temperature | 0℃~45℃ (standard models); recommended operating temperature 22℃±5℃ |
| Humidity | 10%~90% non-condensing; recommended relative humidity 40%~70% |
| Cleanliness | No corrosive gases or conductive dust in the air; server room dust concentration ≤0.1mg/m³ |
| Ventilation | Sufficient ventilation space in front and rear of equipment; air intakes and exhausts unobstructed |
| Electromagnetic Environment | Keep away from strong electromagnetic interference sources such as high-power motors, transformers, and radar equipment |
Rack Installation Conditions
- Use standard 19-inch racks with cabinet depth ≥800mm, reserving equipment installation space.
- Rack grounding must be reliable with grounding resistance ≤4Ω.
- Rack must have reliable load-bearing capacity; reserve load capacity for maximum 25kg per device.
- Reserve sufficient power outlets in the rack; redundant power supplies require two independent power circuits.
Power Supply Requirements
- Supply voltage: AC 100V~240V, frequency 50Hz±5%.
- Supply stability: Voltage fluctuation range not exceeding ±10%, no frequent power interruptions.
- UPS uninterruptible power supply is recommended to ensure continuous stable equipment operation.
- Power circuits must have reliable grounding protection, with neutral-ground voltage ≤1V.
9.1.2 Tools and Materials Preparation
The following tools and auxiliary materials must be prepared before installation:
| Category | Items |
|---|---|
| Installation tools | Phillips screwdriver (PH2), flathead screwdriver, hex key set, adjustable wrench, ESD wrist strap, marker pen, tape measure |
| Auxiliary materials | Network cables, fiber patch cords (prepare according to interface type), cable ties, label paper, cable management brackets |
| Debugging tools | 1 laptop, serial debugging cable, Console-to-USB adapter (if required), network cable tester |
9.1.3 Personnel and Safety Preparation
- Installation personnel must have basic network equipment installation experience and be familiar with server room operating procedures.
- The installation process must strictly comply with server room safety management regulations. Wear ESD wrist straps to prevent static damage to equipment components.
- Before power-on, verify that the supply voltage matches the equipment’s rated voltage to prevent equipment burnout due to incorrect voltage.
- Heavy equipment must be moved by two people working together to prevent equipment drop causing personal injury or equipment damage.
9.1.4 Unpacking and Inspection
- Remove the outer packaging, take out the equipment and all accessories, and verify against the packing list item by item.
- Inspect the equipment exterior for scratches, paint chipping, deformation, and check interfaces for damage or looseness.
- Verify that the equipment model and serial number match the order.
- After confirmation, complete the goods receipt confirmation form and retain the warranty card and other credentials.
9.2 Rack Installation Steps
The LA-GAP series gateway is a standard 19-inch rack-mount device installed in a standard rack. The specific installation steps are as follows:
Step 1: Determine Installation Position
Based on network topology planning, select an appropriate installation height in the rack. It is recommended to install in the middle-to-upper section of the rack for convenient cabling and routine maintenance. Reserve at least 1U of heat dissipation space above and below the device, avoiding tight installation against other equipment.
Step 2: Install Mounting Brackets
- Place the device on a stable work surface with the side facing up.
- Take out the included mounting brackets and align them with the mounting holes on the device sides.
- Secure the brackets to both sides of the device using the included screws, ensuring they are firmly attached without loosening.
- Note the bracket orientation — the protruding edge on the front panel side faces forward for mounting to the rack rails.
Step 3: Mount the Device into the Rack
- Two people coordinate to lift the device and place it smoothly into the designated position in the rack.
- Align the bracket holes with the rack square holes, and first insert positioning pins for preliminary fixing.
- Tighten all four rack fixing screws in sequence, ensuring the device is mounted level and securely in the rack.
- Gently push the device to confirm there is no looseness or wobble and that it is firmly installed.
Step 4: Grounding Connection
- Locate the grounding terminal on the device’s rear panel.
- Connect the included grounding cable from the device to the rack grounding bus bar.
- Tighten the grounding terminal screw to ensure good contact.
- The rack grounding must be reliably connected to the server room’s combined grounding grid, with grounding resistance meeting server room standards.
9.3 Installation Precautions
- Ventilation and Heat Dissipation: The device air intake is on the front panel and the exhaust is on the rear panel. During installation, ensure the front and rear are unobstructed — maintain at least 50mm from the front to the rack door and reserve at least 100mm cabling space at the rear.
- Load-Bearing Safety: The rack shelf must have sufficient load-bearing capacity. It is forbidden to place the device directly on non-load-bearing shelves.
- Electrostatic Protection: Throughout the entire installation process, operators must wear ESD wrist straps and avoid directly touching circuit boards, interface pins, and other components.
- Labeling: After installation, promptly affix identification labels to the device indicating device name, network affiliation, management IP, and other information for subsequent O&M.
- Space Reservation: Reserve maintenance space in the rack for future device replacement, module expansion, and troubleshooting.
9.4 Installation Acceptance Standards
After equipment installation is complete, the installation quality shall be accepted according to the following standards:
| Acceptance Item | Standard |
|---|---|
| Equipment stability | Firmly installed, no looseness or tilting, levelness deviation ≤2mm |
| Fastener integrity | All bracket screws and rack screws fully tightened, none missing |
| Grounding reliability | Grounding connection resistance ≤0.5Ω |
| Equipment appearance | Intact appearance, no scratches, paint chipping, deformation, or other installation damage |
| Ventilation space | Adequate front and rear ventilation space, unobstructed |
| Labeling | Equipment identification labels clear and accurate |
Chapter 10 Product Wiring
10.1 Interface Description
All external interfaces are integrated on the device rear panel. Before wiring, the definition and purpose of each interface must be understood. Taking the LA-GAP-500 model as an example, the rear panel interface layout is as follows:
| Interface Area | Interface Name | Designation | Description |
|---|---|---|---|
| External Network Area | External Business Ports 1–6 | WAN1–WAN6 | Connect to external network/low-security side network switches |
| External Network Area | External Optical Ports 1–2 | W-SFP1–W-SFP2 | External network side fiber optic business interfaces |
| External Network Area | External Management Port | W-MGT | External network side device management interface |
| External Network Area | External Console Port | W-CON | External network side serial port configuration interface |
| Internal Network Area | Internal Business Ports 1–6 | LAN1–LAN6 | Connect to internal network/high-security side network switches |
| Internal Network Area | Internal Optical Ports 1–2 | L-SFP1–L-SFP2 | Internal network side fiber optic business interfaces |
| Internal Network Area | Internal Management Port | L-MGT | Internal network side device management interface |
| Internal Network Area | Internal Console Port | L-CON | Internal network side serial port configuration interface |
| Common Area | Power Interfaces 1–2 | PWR1–PWR2 | AC power input interfaces |
| Common Area | Grounding Terminal | GND | Equipment protective grounding |
| Common Area | Expansion Slot | EXP | Optional function module expansion slot |
Note: The internal network side interfaces and external network side interfaces are completely physically independent and belong to different host systems. It is strictly prohibited to reverse-connect internal and external network interfaces during wiring, as this would cause security isolation failure.
10.2 Power Cable Wiring
10.2.1 Wiring Steps
1. Confirm that the device power switch is in the “OFF” position.
2. Insert the first power cable into the device PWR1 power interface and tighten the locking clip.
3. Insert the other end of the power cable into the PDU outlet of the first power circuit and confirm it is fully seated.
4. Repeat the above steps to connect the second power cable to the PWR2 power interface and the second power circuit.
5. For redundant power supplies, it is recommended to connect to different power circuits — one to mains power and one to UPS power — to improve power supply reliability.
10.2.2 Precautions
- The power cable must be the original equipped national standard three-pin power cable. Using inferior non-standard cables is prohibited.
- The power plug must be reliably grounded. Using non-grounded two-pin outlets is prohibited.
- Route power cables away from cooling vents and away from high-temperature areas.
- Leave a small amount of slack at the cable connection points to avoid loosening from pulling.
10.3 Business Network Cable Wiring
10.3.1 Wiring Specifications
- Use Category 5e or Category 6 unshielded twisted pair cable, with transmission distance not exceeding 100 meters.
- Terminate both ends of the cable using T568B wiring standard, with firmly crimped connectors and no false connections.
- Use a cable tester to verify connectivity before wiring, ensuring all 8 cores pass with no crosstalk or open circuits.
- Route internal and external network cables separately and clearly label them to avoid confusion.
10.3.2 Wiring Steps
External Network Wiring: Insert the network cable connected to the external network core switch into the external network business port (WAN port) of the device. A “click” sound indicates it is fully inserted.
Internal Network Wiring: Insert the network cable connected to the internal network core switch into the internal network business port (LAN port) of the device. Confirm it is fully inserted.
For multi-business-interface scenarios, connect different business links to the corresponding interfaces according to the plan, labeling each accordingly.
After wiring is complete, observe the interface indicator lights. Under normal conditions, the green LED stays lit when the link is established, and the yellow LED blinks during data transmission.
10.3.3 Fiber Optic Interface Wiring
Optical Module Installation: Gently insert the SFP/SFP+ optical module into the corresponding optical port until it clicks into place. Do not use excessive force as this may damage the optical port.
Fiber Patch Cord Connection: Remove the dust caps from both the optical module and the fiber patch cord connectors. Insert the fiber patch cord into the optical module. Ensure the fiber end faces are clean and free from dust contamination.
For single-mode fiber, note the transmit/receive direction: Tx connects to the opposite end’s Rx, and Rx connects to the opposite end’s Tx.
Fiber bending radius must be ≥30mm to avoid excessive optical signal attenuation.
10.4 Management Interface Wiring
The gateway supports two management methods: local serial port management and network management. The corresponding interface wiring is as follows:
10.4.1 Console Serial Port Wiring
1. Take out the included Console configuration cable. Insert the RJ45 connector into the device Console port.
2. Connect the DB9 serial connector to the serial port of the debugging computer. If the computer has no serial port, use a USB-to-serial adapter.
3. Default serial port parameters: baud rate 115200, data bits 8, stop bits 1, no parity, no flow control.
10.4.2 Management Network Port Wiring
- External Management Port: Connect to the external network management network for managing the device from the external network side.
- Internal Management Port: Connect to the internal network management network for managing the device from the internal network side.
- The management ports are physically separated from business ports. It is recommended to establish a separate management network to enhance management security.
- During initial configuration, you can directly connect a network cable between a laptop and the management port for local configuration.
10.5 Wiring Sequence and Principles
10.5.1 Recommended Wiring Sequence
| Step | Operation |
|---|---|
| Step 1 | Connect the grounding cable |
| Step 2 | Connect management interface cables |
| Step 3 | Connect business interface cables (internal network first, then external network) |
| Step 4 | Connect power cables |
| Step 5 | Power on and check status |
10.5.2 Core Wiring Principles
- Strict Internal/External Separation: Internal and external network cables must be routed separately and labeled separately. Reversing interfaces is strictly prohibited, as this would directly expose the high-security network and create serious security hazards.
- Clear Labeling: Both ends of all cables must be labeled with the local interface, remote device, and remote interface information for subsequent O&M troubleshooting.
- Tidy Routing: Route cables along the rack cable management brackets and secure them with cable ties. Avoid clutter and do not block equipment ventilation openings.
- Separation of Power and Signal Cables: Power cables and network cables must be routed separately with at least 30cm spacing to avoid electromagnetic interference.
10.6 Wiring Acceptance Standards
After wiring is complete, acceptance shall be performed according to the following standards:
| Acceptance Item | Standard |
|---|---|
| Connection firmness | All cables securely connected, no looseness or false connections |
| Interface labeling | Interface labels clear, no reversed internal/external connections |
| Business link status | Business interface links normal, indicator lights correct, no errors |
| Cable routing | Tidy cable routing, standardized labels, power/signal separation |
| Grounding and power | Grounding connection reliable, power supply normal |
| Optical power | Fiber interface optical power within normal range, received optical power ≥-12dBm |
Chapter 11 Product Commissioning
11.1 Pre-Commissioning Preparation
11.1.1 Documentation Preparation
- This installation and commissioning manual.
- Project network topology diagram, clearly indicating gateway deployment position, internal/external network segments, and business system addresses.
- Business requirements list, clearly identifying the business types, protocols, and access relationships to be enabled.
- IP address planning table, including gateway internal/external network interface IPs, management IPs, gateways, and related information.
11.1.2 Tool Preparation
- One debugging laptop with serial port debugging tools (e.g., SecureCRT, PuTTY) and a browser installed.
- Console debugging cable and network cable.
- Test clients and servers for business connectivity verification.
- Relevant business system account permissions for testing business functions.
11.1.3 Power-On Self-Test
After device wiring is complete, perform a power-on self-test to confirm normal hardware operation:
1. Turn on the device power switch and observe the front panel power indicator lights. PWR1 and PWR2 lights staying lit indicates normal power supply.
2. During startup, the RUN indicator blinks. After approximately 3–5 minutes, the system completes startup, and the RUN light blinks at a steady rhythm.
3. Observe the alarm indicator ALM — it should go off after normal startup. If it stays lit, a hardware fault exists.
4. After connecting network cables to business interfaces, the corresponding link indicator lights should illuminate, blinking during data transmission.
If abnormal conditions occur after power-on — such as power lights not illuminating, fans not spinning, or alarm lights staying lit — power off immediately and troubleshoot. Contact the manufacturer’s technical support if necessary.
11.2 Initial Configuration (Serial Port Method)
Initial configuration requires logging into the device through the Console serial port for basic network parameter configuration. The specific steps are as follows:
11.2.1 Serial Port Login
1. Connect the Console cable between the computer’s serial port and the device’s external network side Console port.
2. Open the serial port debugging tool and create a new serial connection with the following parameters: baud rate 115200, data bits 8, stop bits 1, no parity, no flow control.
3. After device startup completes, press Enter to display the login prompt.
4. Enter the default administrator account and password (default account: admin, default password: refer to the password letter included with the product manual).
5. On first login, the system requires the default password to be changed. Follow the prompts to set a new administrator password that meets complexity requirements (8+ characters, including uppercase letters, lowercase letters, numbers, and special characters).
11.2.2 Configure External Network Side Management IP
# Enter system view system-view # Enter external management interface view interface mgt-wan # Configure IP address and mask ip address 192.168.1.1 255.255.255.0 # Enable the interface undo shutdown # Return to system view quit # Configure external network side default gateway (if cross-subnet management is needed) ip route-static 0.0.0.0 0.0.0.0 192.168.1.254
11.2.3 Configure Internal Network Side Management IP
After logging in via the external network serial port, you can switch to the internal network unit for configuration, or connect to the internal network Console port separately:
# Switch to internal network unit configuration mode switch-to-lan # Enter internal management interface view interface mgt-lan # Configure IP address and mask ip address 192.168.2.1 255.255.255.0 # Enable the interface undo shutdown # Configure internal network side gateway ip route-static 0.0.0.0 0.0.0.0 192.168.2.254 # Return to external network unit switch-to-wan
11.2.4 Verify Management Connectivity
After configuration is complete, set the debugging computer’s IP to the same subnet and use the ping command to test connectivity to the gateway’s management IP. Once normal access is confirmed, subsequent configuration can be performed via the Web interface.
11.3 Web Management Interface Login and Basic Configuration
11.3.1 Web Login
1. Open a browser and enter https://external-management-IP, for example: https://192.168.1.1.
2. When the browser displays a certificate risk warning, select “Continue to site” (the device uses a default self-signed certificate that can be replaced with a formal certificate later).
3. On the login page, enter the administrator account and the changed password, then click Login.
4. On first login, the configuration wizard appears. You can follow the wizard to complete basic configuration step by step, or skip the wizard and configure manually.
11.3.2 System Basic Configuration
- Device Information Configuration: Navigate to 【System Management】-【Device Information】to set the device name, device location, administrator contact information, and other details for device asset management.
- Time Configuration: Navigate to 【System Management】-【Time Settings】to configure the system time. It is recommended to enable NTP automatic synchronization and set the internal network NTP server address to ensure accurate log timestamps.
- Administrator Configuration: Navigate to 【System Management】-【Administrators】to create System Administrator, Security Administrator, and Audit Administrator accounts per the separation of powers principle, assign corresponding permissions, and disable the default account.
- Management Access Control: Configure the login IP whitelist to only allow designated IP addresses to access the management interface, enhancing management security.
11.4 Business Interface and Route Configuration
11.4.1 External Network Business Interface Configuration
1. Navigate to 【Network Configuration】-【External Interfaces】and select the external network business interface to be used.
2. Configure the interface IP address and subnet mask, and enable the interface.
3. For multiple interfaces, configure different subnet IPs or sub-interfaces as needed.
4. Configure the interface MTU value (default: 1500) and adjust according to the actual network environment.
11.4.2 Internal Network Business Interface Configuration
1. Navigate to 【Network Configuration】-【Internal Interfaces】and select the corresponding internal network business interface.
2. Configure the interface IP address and subnet mask, ensuring reachability to the internal network subnet.
3. The internal interface IP must be in the same subnet as the internal business servers or switches, or have a reachable route configured.
11.4.3 Static Route Configuration
1. Navigate to 【Network Configuration】-【Route Management】-【Static Routes】.
2. External Network Side Routing: Add a static route for external network subnets, specifying the next hop as the external switch address to ensure external users can reach the gateway’s external interface.
3. Internal Network Side Routing: Add a static route for internal business subnets, specifying the next hop as the internal core switch address to ensure the gateway can access internal business servers.
4. After configuration, use the system’s built-in ping tool to test internal and external connectivity and confirm routes are reachable.
11.5 Business Channel Configuration
A business channel is the core configuration unit for the gateway to implement data ferry. Each business channel corresponds to the exchange of one type of business data. Select the corresponding channel template based on the business protocol type. The following describes the configuration methods for common business channels:
11.5.1 HTTP Access Channel Configuration (External Network Accessing Internal Web Server)
Requirement Scenario: External network users need to access internal Web business systems; use gateway proxy for secure access.
1. Navigate to 【Business Configuration】-【Channel Management】and click 【New Channel】.
2. Select channel type 【HTTP Proxy】and transmission direction 【External → Internal】.
3. Fill in the channel name and channel description, and enable the channel.
4. External Network Side Configuration:
- Listening address: External network business interface IP.
- Listening port: Custom, e.g., 8080.
- Access control: Configure external IP whitelist for allowed access.
5. Internal Network Side Configuration:
- Real server address: Internal Web server IP.
- Real server port: Internal Web service port, e.g., 80.
6. Security Policy Configuration:
- Enable URL filtering and configure the URL whitelist for allowed access.
- Enable content detection and turn on SQL injection and XSS protection.
- Enable virus scanning for uploaded files.
7. Click 【OK】to save the configuration; the channel takes effect automatically.
11.5.2 File Exchange Channel Configuration
Requirement Scenario: File transfer is needed between internal and external networks, supporting both file upload and download.
1. Create a new channel with type 【File Exchange Proxy】.
2. Select transmission direction as 【Bidirectional】or designate a single direction.
3. Configure the file exchange working mode:
- Directory mapping mode: Map shared directories on internal and external servers, automatically synchronizing files.
- Client mode: Users upload and download files through a dedicated client.
4. Configure file security policies:
- File type whitelist, e.g., only allow document files such as doc, pdf, xls.
- Limit single file size.
- Enable virus scanning.
- Enable sensitive keyword detection.
5. Configure file audit policies to record all file transfer logs.
11.5.3 Database Synchronization Channel Configuration
Requirement Scenario: Data synchronization is needed between internal and external network databases, such as synchronizing external business data to the internal database.
1. Create a new channel with type 【Database Synchronization Proxy】.
2. Select the database type: Oracle, MySQL, SQL Server, DM (Dameng), etc.
3. Configure source and destination database connection information: address, port, database name, account, and password.
4. Configure synchronization rules:
- Select the tables to synchronize.
- Configure synchronization fields with field-level filtering support.
- Set synchronization conditions to synchronize only specific data subsets.
- Configure synchronization frequency: real-time or scheduled.
5. Enable data validation to ensure data integrity during synchronization.
6. Save the configuration and start the synchronization task.
11.5.4 Industrial Protocol Channel Configuration
Requirement Scenario: An external network management system needs to collect data from internal network industrial control devices.
1. Create a new channel and select the corresponding industrial protocol type, e.g., 【Modbus TCP Proxy】.
2. Select the transmission direction based on business needs, typically Internal → External (data collection) or Bidirectional.
3. Configure industrial device address, port, device slave ID, and other parameters.
4. Configure the instruction whitelist: only allow read/write commands for preset function codes and register addresses.
5. For data collection scenarios, disable all write operation commands and only enable read commands to enhance industrial control system security.
11.6 Security Policy Configuration
11.6.1 Access Control Policy
1. Navigate to 【Security Policy】-【Access Control】to configure global access control rules.
2. Set the default policy to “Deny All” — only allow data from explicitly configured business channels.
3. Configure IP blacklists to block all access from known malicious IP addresses.
4. Configure access frequency limits to prevent brute-force attacks and DDoS attacks.
11.6.2 Content Security Policy
1. Navigate to 【Security Policy】-【Content Security】to enable the global virus scanning function and configure automatic virus database updates.
2. Configure sensitive information detection rules, adding custom sensitive keywords and regular expressions.
3. Enable file type validation to block dangerous file types such as executable files and script files.
4. Configure Web attack protection rules, enabling SQL injection, XSS, command injection, and other protections.
11.6.3 Log Audit Configuration
1. Navigate to 【System Management】-【Log Configuration】to enable various log recording functions.
2. Configure the log retention period (default: 6 months), adjustable per compliance requirements.
3. Configure a remote log server (Syslog) to synchronize logs to a unified log audit platform.
4. Configure log alert rules to trigger real-time alerts for critical security events.
11.7 Functional Verification and Testing
After all configurations are complete, comprehensive functional verification must be performed to ensure business operations are normal and security policies are effective.
11.7.1 Connectivity Testing
- From an external network client, test accessing the gateway’s external proxy address and port to verify successful connection establishment.
- Verify business functions work correctly: Web pages open properly, files transfer normally, and databases synchronize correctly.
- Test whether internal network servers can receive and respond to requests normally.
- Test access from unauthorized IPs and unauthorized ports to verify they are correctly blocked.
11.7.2 Security Policy Verification
- Upload a test virus file to verify the virus scanning function works and blocks as expected.
- Attempt to upload prohibited file types to verify file type filtering is effective.
- Construct SQL injection test requests to verify Web attack protection is effective.
- Test content containing sensitive keywords to verify sensitive information detection blocks it correctly.
11.7.3 Performance Testing
- Monitor device CPU and memory utilization. Resource utilization during business peak periods should be below 70%.
- Test business throughput to verify it meets business bandwidth requirements.
- Test concurrent connection capacity to verify support for peak business concurrency.
11.7.4 High Availability Testing (if dual-machine deployment)
- Simulate primary device power failure to test whether the standby device automatically takes over and whether business is interrupted.
- Test whether the system automatically switches back to the primary/standby state after the primary device recovers.
- Test single link disconnection to verify link aggregation switches over correctly.
11.8 Configuration Backup and Delivery
After commissioning is complete, perform the following closing tasks:
- Navigate to 【System Management】-【Configuration Management】, export the current configuration file, and save a backup at an off-site location;
- Record all configuration information, compile a project configuration document, and deliver it to the user’s operations and maintenance personnel;
- Provide basic operation training to the user’s operations and maintenance personnel, covering daily O&M essentials and alarm handling procedures;
- Complete the commissioning record form, obtain signatures from both parties for confirmation, and finalize the commissioning delivery.
12.1 Installation and Deployment Precautions
Internal/External network interfaces must never be connected in reverse: This is the most critical security red line in gateway deployment. The internal network interface must be connected to the higher-security network, and the external network interface to the lower-security network. Connecting them in reverse will directly expose the internal network to external risks, causing serious security incidents. After deployment, two personnel must jointly verify the correctness of interface connections.
Direct Internet connection is prohibited: The external network side of the gateway also belongs to the boundary protection area. Direct exposure to the public network is prohibited. It is recommended to deploy firewalls, DDoS protection, and other devices in front of the external network side to share the basic attack protection load.
Bypassing the gateway is prohibited: After gateway deployment, no other network connections may be privately established between the internal and external networks, such as privately run cables, wireless bridges, mobile hotspots, etc. All cross-network data must pass through the gateway; otherwise, the isolation protection becomes meaningless.
Management port security: Management interfaces must not be connected to the business network, and public IP addresses must not be configured. It is recommended to establish a dedicated management network, with access to management interfaces restricted to authorized O&M personnel only.
Deployment location selection: The gateway should be deployed in a secure area of the equipment room, with physical access restrictions to prevent unauthorized physical contact and operation.
12.2 Configuration and Operation Precautions
Default passwords must be changed: The factory default password is only for initial configuration. It must be changed immediately upon first login, and the password must meet complexity requirements and be changed periodically. Weak passwords and common passwords are prohibited.
Separation of three administrative powers must be implemented: Strictly configure the three types of accounts — system administrator, security administrator, and audit administrator — in accordance with standards, with separated privileges. One person holding multiple types of account privileges is prohibited.
Policies must follow the principle of least privilege: Security policy configuration should adopt a whitelist model, only opening ports, protocols, and IP ranges necessary for business operations. Loose “allow all” policies are prohibited.
Configuration changes require approval: All security policy changes and system configuration modifications must go through an approval process, with change records maintained. After changes, business and security effectiveness must be verified promptly.
Regular configuration backups: Back up configuration files in a timely manner after each configuration change and periodically export backups to ensure rapid configuration recovery in the event of device failure.
Debugging features must not be casually enabled: Debug ports and remote maintenance functions must be closed promptly after use and must not remain open long-term.
12.3 Operational Precautions
No arbitrary power-off: Directly unplugging the power to shut down during operation is prohibited. Shutdown must be performed through the management interface, waiting for the system to close properly before cutting power, to prevent system file damage.
Regular operating status checks: Perform daily inspections of device operating status, checking CPU, memory, and disk utilization, reviewing alarm information, and promptly handling any anomalies found.
Pay attention to security updates: Promptly follow manufacturer-released security patches, antivirus database updates, and system version upgrades. Update regularly to fix known security vulnerabilities.
Regular log audits: Designate personnel to regularly audit device logs, focusing on abnormal access, blocking records, and alarm events, promptly identifying potential security threats.
No unrelated software installation: The gateway is a dedicated security device. Installing any third-party software or running unrelated programs on the device is prohibited to avoid introducing security risks.
USB port control: Except for upgrade and maintenance scenarios, USB ports should be disabled during normal operations to prevent virus transmission via USB drives or unauthorized data copying.
12.4 Physical Environment Precautions
Temperature and humidity control: The equipment room must maintain the specified temperature and humidity ranges to avoid accelerated device aging due to high temperature and humidity, which can lead to hardware failures.
Dust protection: Keep the equipment room clean and regularly clean the dust filters at the device air intakes to prevent dust accumulation from affecting heat dissipation or even causing circuit short circuits.
Anti-static: Static wrist straps must be worn when handling device hardware to prevent static discharge from damaging chips. The equipment room should maintain appropriate humidity to avoid static buildup.
Electromagnetic interference protection: Keep devices away from strong electromagnetic sources. Use shielded cables to prevent electromagnetic interference from causing data transmission errors and abnormal device operation.
Water and moisture protection: Device installation locations should avoid areas below air conditioner vents and water pipes to prevent condensation and water leakage from damaging the equipment.
12.5 Compliance Precautions
No unauthorized change of use: The gateway is a security-specific product that must be used within its approved scope. Unauthorized modification of device functions, system cracking, or use for illegal purposes is prohibited.
Classified scenario compliance: Gateways used in classified environments must use models with classified product qualifications. Operation and maintenance management must comply with confidentiality regulations. Classified devices must not be connected to non-classified networks.
Log retention compliance: Logs must be retained in accordance with compliance requirements such as Multi-Level Protection Scheme (MLPS) and graded protection. Log retention must not be less than 6 months, and no less than 1 year for important scenarios.
Regular compliance assessments: Cooperate with MLPS and graded protection assessment activities, conduct regular security testing, and ensure the device continuously meets compliance requirements.
13.1 Daily Inspection and Maintenance
Daily inspection is the foundation for ensuring long-term stable operation of the equipment. It is recommended to conduct an on-site inspection daily and a remote system inspection weekly, with detailed records of inspection results.
13.1.1 Daily On-Site Inspection Content
Appearance and environment inspection:
- Check whether the device appearance is intact, with no abnormal sounds or odors;
- Check whether the equipment room temperature and humidity are within the normal range;
- Check the device indicator light status — whether the power, operation, and alarm lights are normal;
- Check whether the port indicator lights are normal and whether there are any link interruptions.
Physical connection inspection:
- Check whether power cables, network cables, and fiber optic cables are firmly connected, without looseness or detachment;
- Check for damage or aging of cables;
- Check whether the equipment grounding is reliable.
Cooling system inspection:
- Listen for abnormal sounds in fan operation;
- Check whether the air intake dust filters are clogged and whether ventilation is smooth;
- Feel the temperature at the device exhaust outlet and check for abnormally high temperatures.
13.1.2 Weekly System Inspection Content
System resource inspection:
- Log in to the web management interface and check CPU utilization — should normally be below 70%;
- Check memory utilization — should normally be below 70%;
- Check disk utilization — system disk utilization below 80%, and log disk should be cleaned periodically.
Business status inspection:
- Check the operating status of all business channels — whether all are running normally;
- Check port traffic statistics for abnormal traffic fluctuations;
- Check concurrent connection count — whether within the normal range.
Security event inspection:
- Check security alarm logs for abnormal attack events and virus interception events;
- Check administrator login logs for unauthorized login attempts;
- Check system error logs for abnormal system errors.
Data backup inspection:
- Confirm that configuration backups and log backups execute normally;
- Check whether the virus database and rule database are the latest versions.
13.2 Regular Maintenance
In addition to daily inspections, regular deep maintenance must be performed on the equipment. It is recommended to perform a minor maintenance quarterly and a comprehensive maintenance annually.
13.2.1 Quarterly Maintenance Content
Clean dust filters:
- Power off the device or wear anti-static wrist straps, then remove the front panel dust filters;
- Clean dust with a brush, or wash with clean water and air-dry before reinstalling;
- Cleaning frequency may be increased appropriately in dusty environments.
Cable tightening:
- Re-tighten all interface cable screws to prevent poor contact;
- Organize cabinet cables and replace aged or damaged cables;
- Check whether labels are clear and reprint any fallen labels.
Configuration and log backup:
- Export the latest configuration files and archive them off-site;
- Archive historical logs to free up disk space.
13.2.2 Annual Comprehensive Maintenance Content
Internal cleaning (requires professional personnel):
- Remove the device from the rack, power it off, and open the chassis cover;
- Use anti-static brushes and a vacuum cleaner to clean dust accumulated on internal circuit boards, fans, and heat sinks;
- During cleaning, avoid touching component pins to prevent static damage.
Hardware status inspection:
- Check whether power supply output voltage is normal;
- Check fan speed and bearing condition, replacing aged fans;
- Check the communication quality of each interface to identify potential faults.
System deep maintenance:
- Clean system junk files and temporary files;
- Check disks for bad sectors and repair file system errors;
- Upgrade to the latest stable system version and install security patches;
- Comprehensively test all functions to verify device operating status.
Performance optimization:
- Optimize security policies, removing expired and redundant rules;
- Adjust system parameters to match current business loads;
- Assess whether device performance meets business growth needs and provide expansion recommendations.
13.3 Fault Repair Procedures
When a device fault occurs, follow the procedures below to ensure rapid fault recovery and minimal business impact.
13.3.1 Fault Classification
- Level 1 fault (critical): Complete device downtime, total business interruption, affecting core business operations;
- Level 2 fault (serious): Partial business channel failure, partial interface failure, partial business interruption;
- Level 3 fault (general): Device alarms, performance degradation, but business not interrupted;
- Level 4 fault (minor): Cosmetic issues or indicator light problems that do not affect business operation.
13.3.2 Fault Handling Steps
Fault reporting: Upon discovering a fault, immediately record the fault phenomenon, time, and scope of impact, report to the O&M manager, and simultaneously contact the manufacturer’s technical support hotline: +86 13538869979.
Preliminary investigation:
- Check device indicator lights and alarm information to preliminarily determine the fault type;
- Check power supplies, cables, switches, and other peripheral devices to rule out external factors;
- Restart the corresponding business channel or non-core module and observe whether it recovers;
- In dual-machine deployment scenarios, first switch to the standby machine to restore business, then investigate the fault.
Remote assistance:
- Cooperate with manufacturer technical support personnel for remote diagnosis;
- Provide fault screenshots, log information, and configuration information;
- Perform troubleshooting operations under the guidance of technical support.
On-site repair:
- For faults that cannot be resolved remotely, the manufacturer will arrange an engineer for on-site repair;
- For hardware faults, prioritize replacing with a standby machine or spare parts to quickly restore business;
- Faulty equipment is returned to the factory for repair, and exchanged back after repair completion.
Fault review:
- After fault resolution, record the fault cause, handling process, and solution;
- Analyze the root cause of the fault and formulate preventive measures to avoid recurrence of similar faults;
- Update the emergency response plan and O&M manual.
13.4 Maintenance Precautions
Hardware repair qualifications: Hardware repairs must be performed by manufacturer-authorized professionals. Users are prohibited from disassembling the device privately, as private disassembly will void the warranty.
Spare parts replacement requirements: Replacement hardware modules must use genuine factory spare parts. Third-party compatible parts are prohibited to avoid device faults or security vulnerabilities.
Classified device repair: Repairs of gateways used in classified scenarios must comply with confidentiality regulations. On-site repair is preferred. If return to factory is necessary, declassification processing must be performed, with confidentiality personnel supervising throughout.
Safety during maintenance: Protect data during maintenance. Leaking sensitive information such as device configuration and business data is prohibited. After maintenance, clean up repair tools to prevent foreign objects from being left inside the device.
Maintenance verification: After repair completion, comprehensively test device functions, performance, and security policies. Only after confirming full recovery to normal may the device be returned to formal operation.
13.5 Warranty Service Description
Warranty period: This product provides a three-year original factory warranty. The warranty period commences from the date of factory acceptance of the equipment.
Warranty scope: During the warranty period, for hardware faults and software defects not caused by human damage or force majeure, the manufacturer provides free repair, free spare parts replacement, and free technical support services.
Warranty exclusions: The following situations are not covered by the free warranty:
- Damage caused by human action, private disassembly, or modification;
- Damage caused by external factors such as reversed power connection, abnormal voltage, lightning strikes;
- Damage caused by environmental factors such as water ingress, moisture, high temperature, corrosion;
- Damage caused by failure to operate as per the instruction manual or use of non-genuine parts;
- Damage caused by force majeure (earthquake, fire, flood, etc.).
Extended warranty services: After the warranty period expires, extended warranty services may be purchased to continue enjoying original factory warranty and technical support.
14.1 Hardware Common Problems
Problem 1: Power light does not illuminate after power-on; device completely unresponsive
Possible causes:
- Power cable not firmly inserted; power outlet has no power;
- Power switch not turned on;
- Power module failure;
- Internal power interface loose.
Troubleshooting steps:
1. Check whether both ends of the power cable are firmly inserted, test with a different outlet to confirm normal power supply;
2. Confirm the power switch on the device rear panel is set to the “ON” position;
3. For redundant power supply models, test whether the other power input works normally to determine if it is a single power supply fault;
4. Replace with a power cable of the same specification to rule out cable issues;
5. If the device still cannot be powered on after the above operations, it is determined to be a power module or motherboard failure — contact the manufacturer for after-sales repair.
Problem 2: Alarm light remains on after device startup
Possible causes:
- Single power supply fault (redundant power supply models);
- Fan failure/stopped rotation;
- Device temperature too high;
- Hardware self-test failed, memory or storage fault;
- Isolation unit communication anomaly.
Troubleshooting steps:
1. Log in to the management interface, check system alarm information, and locate the specific alarm item;
2. Check whether both power supplies are functioning and confirm power cable connections are secure;
3. Listen to fan operation sounds to determine whether any fan is not rotating;
4. Check whether the equipment room temperature is too high and ventilation is adequate;
5. Restart the device and observe the startup process for error messages;
6. If it is a hardware fault, record the alarm code and contact manufacturer technical support.
Problem 3: Port indicator light does not illuminate after inserting network cable; link is down
Possible causes:
- Network cable fault or incorrect wire sequence;
- Peer switch port fault or not enabled;
- Gateway port disabled by administrator;
- Port hardware damage;
- Speed/duplex mode mismatch.
Troubleshooting steps:
1. Replace with a known-good network cable to rule out cable issues;
2. Insert the cable into another known-good port to test whether the peer switch port is functioning;
3. Log in to the management interface, check the port status, and confirm the port is enabled;
4. Check the port speed/duplex configuration — it is recommended to set to auto-negotiation or ensure both ends are configured consistently;
5. Test with another business port on the gateway to determine whether a single port is damaged;
6. Verify whether the internal/external network interfaces are reversed and whether the corresponding network is correct.
Problem 4: Abnormal noise during device operation
Possible causes:
- Dust accumulation or bearing aging in fans, causing abnormal rotation noise;
- Screws or foreign objects fallen inside the chassis;
- Power supply coil whine;
- Hard disk abnormal noise.
Troubleshooting steps:
1. Determine the source of the noise — whether from the fan area or power supply area;
2. If fan noise, clean the dust filters and observe whether it improves; if not, replace the fan;
3. If accompanied by rising temperature alarms, shut down immediately for inspection to prevent overheating damage;
4. Power supply coil whine typically indicates aging power supply components, requiring replacement of the power module;
5. Do not allow the device to run long-term with abnormal noise — contact after-sales service promptly.
14.2 Network Connectivity Common Problems
Problem 5: Client cannot access the gateway proxy address
Possible causes:
- Network between client and gateway external network interface is down;
- Business channel not enabled or misconfigured;
- Access control policy blocks the client IP;
- Incorrect gateway external network-side route configuration;
- Intermediate devices (e.g., firewalls) block the access port.
Troubleshooting steps:
1. Ping the gateway external network interface IP from the client to confirm network connectivity; if unreachable, investigate intermediate routing and links;
2. Log in to the gateway management interface, check the corresponding business channel status, and confirm it is enabled;
3. Check the channel access control rules and confirm the client IP is within the whitelist;
4. Check the gateway external-side route to confirm the return route can reach the client subnet;
5. From the client, telnet to the gateway proxy port to test port reachability; if unreachable, investigate intermediate security device policies;
6. Check the gateway blocking logs to confirm whether the request was intercepted by security policies.
Problem 6: Business channel status is normal, but access has no response
Possible causes:
- Network between gateway and internal network server is down;
- Server port not open or service not running;
- Incorrect internal-side route configuration; server return packets cannot reach the gateway;
- Server-side firewall blocks the gateway internal network interface IP;
- Protocol proxy configuration parameters incorrect.
Troubleshooting steps:
1. Use the gateway’s built-in ping tool to ping the internal server IP to confirm gateway-to-server reachability;
2. Test whether the corresponding server port is open; you may test by directly connecting from a client on the internal network;
3. Check the server gateway or static route to confirm return packets can reach the gateway internal interface;
4. Temporarily disable the server’s local firewall for testing, or add the gateway internal IP to the whitelist;
5. Verify the server address, port, and protocol type in the channel configuration;
6. Check the internal-side session logs to confirm whether requests reach the internal side.
Problem 7: Data transmission is intermittent and unstable
Possible causes:
- Poor network link quality with severe packet loss;
- Device CPU or memory utilization too high; insufficient processing capacity;
- Dual-machine hot standby switching anomaly;
- Interface speed/duplex mismatch;
- Unstable isolation unit communication.
Troubleshooting steps:
1. Test packet loss rates from client to gateway and from gateway to server; if packet loss is high, investigate link issues;
2. Check device system resource utilization; if CPU or memory exceeds thresholds during peak hours, expansion or policy optimization is needed;
3. Check interface statistics for error packets and dropped packet counts; check network cable and fiber quality;
4. Verify speed and duplex configuration on both ends; force a consistent speed and duplex mode;
5. Check system logs for abnormal reboots or module switching records.
14.3 Business Function Common Problems
Problem 8: File transfer fails with a “blocked” message
Possible causes:
- File type not in the allowed whitelist;
- File size exceeds the limit;
- File detected as containing a virus;
- File contains sensitive keywords;
- Transfer user has insufficient permissions.
Troubleshooting steps:
1. Check the security blocking log to confirm the specific blocking reason;
2. Check the file type whitelist configuration and confirm whether the extension is allowed; note whether the actual file format matches the extension;
3. Check the file size limit configuration and confirm the file size does not exceed the maximum;
4. Update the virus database and rescan to confirm whether it is a false positive; add to whitelist if necessary;
5. Check the sensitive keyword rules; confirm whether a rule was triggered and adjust rules accordingly.
Problem 9: Database synchronization failure
Possible causes:
- Incorrect database connection information; incorrect username/password;
- Insufficient database account privileges, lacking read/write permissions;
- Database firewall blocks the gateway IP;
- Mismatched table structures for synchronization;
- Synchronization data volume too large, causing timeout interruption.
Troubleshooting steps:
1. Test the database connection to confirm the address, port, username, and password are correctly configured;
2. Check database account privileges to ensure it has read/write permissions for the relevant tables;
3. Check the database server firewall and security group to allow the gateway internal IP;
4. Compare table structures on both ends to confirm field names and types match;
5. For large data volume synchronization, consider adjusting the timeout or performing batch synchronization;
6. Check the synchronization task log to identify the specific error message.
Problem 10: Web access is slow with high loading latency
Possible causes:
- Insufficient gateway bandwidth; traffic exceeds throughput ceiling;
- Security inspection consumes resources; content scanning takes time;
- High latency inherent in the network link;
- Slow server response;
- Insufficient gateway system resources.
Troubleshooting steps:
1. Check gateway interface traffic to confirm whether the throughput limit is reached; expand bandwidth for peak periods if needed;
2. Temporarily disable some security inspection features to test speed; if significantly improved, optimize detection policies by lowering inspection levels for trusted sources;
3. Test the direct access speed from client to server to rule out server and link latency issues;
4. Check system CPU and memory utilization; optimize policies or upgrade hardware if resources are insufficient;
5. Check whether content caching, compression, and similar features are enabled; configure them appropriately to improve access speed.
14.4 Management and Operations Common Problems
Problem 11: Forgot administrator password, cannot log in
Solution:
1. Use a Console serial connection to the device and reset the ordinary administrator password via the super administrator password;
2. If the super administrator password is also forgotten, contact manufacturer technical support, provide the device serial number and organization certification, and obtain a password reset solution;
3. Set a new strong password immediately after reset and keep it secure.
Problem 12: Web management interface cannot be accessed
Possible causes:
- Network between management PC and gateway management port is down;
- Management interface disabled or IP address changed;
- Browser incompatibility or certificate issues;
- Management service anomaly;
- Login IP whitelist restricts the access address.
Troubleshooting steps:
1. Ping the management IP to confirm network connectivity; if unreachable, investigate link and IP configuration;
2. Use a Console serial connection to log in and check the management interface status and IP configuration;
3. Try a different browser (Chrome or Firefox) and clear the browser cache;
4. Check the login IP whitelist configuration to confirm the current PC IP is within the allowed range;
5. Restart the web management service via serial console, or restart the device for testing;
6. Confirm whether HTTP is being used — the device only enables HTTPS by default.
Problem 13: Logs are not recorded or are lost
Possible causes:
- Logging function not enabled;
- Disk space full; logs automatically overwritten;
- Log retention period configuration too short;
- System time incorrect; log timestamps wrong;
- Remote log server configuration incorrect; sending failure.
Troubleshooting steps:
1. Navigate to the log configuration page and confirm the corresponding log types are enabled;
2. Check disk utilization; if the log disk is full, configure log rotation and periodic cleanup, or expand storage;
3. Check the log retention period setting and adjust the retention duration according to requirements;
4. Synchronize the system time to ensure accuracy;
5. Test connectivity to the remote Syslog server and verify the port and protocol configuration.
14.5 Security Policy Common Problems
Problem 14: Normal business is incorrectly intercepted by security policies
Solution:
1. Check the blocking log to confirm the specific policy and rule that was triggered;
2. If an IP was incorrectly added to the blacklist, remove that IP;
3. If a file type was misjudged, add the file format to the whitelist;
4. If it is a virus-scanning false positive, submit the sample to the manufacturer for analysis and add a temporary whitelist;
5. If a sensitive keyword rule was incorrectly triggered, optimize the keyword rules and add matching conditions;
6. After adjusting the policies, re-test to confirm normal business operation is restored.
Problem 15: Virus database cannot be upgraded
Possible causes:
- Gateway cannot connect to the upgrade server;
- Upgrade server address configured incorrectly;
- License expired;
- DNS resolution failure.
Troubleshooting steps:
1. Test connectivity from the gateway to the upgrade server; check routing and firewall policies;
2. Verify that the upgrade server address and port configuration are correct;
3. Check device license information to confirm the virus database upgrade license has not expired;
4. Configure a correct DNS server address to ensure the domain name resolves properly;
5. If online upgrade is not possible, download the offline upgrade package and manually import it for upgrade.
15.1 Basic Concepts
Q1: What is the essential difference between a gateway and a firewall? If a firewall is installed, is a gateway unnecessary?
A: The isolation levels of the two are fundamentally different. A firewall provides logical isolation, filtering data packets based on the five-tuple and protocol characteristics. Essentially, it still forwards network data packets. Complete TCP connections exist between the internal and external networks, and attackers can exploit protocol vulnerabilities and 0-day vulnerabilities to bypass the firewall for penetration. A gateway provides physical isolation — there is no direct network connection between the internal and external networks. Data is transmitted as pure data through “protocol stripping + data ferrying + protocol reconstruction.” No end-to-end TCP session exists, which fundamentally blocks network-layer attack paths.
For high-security networks (such as classified networks, industrial control networks, and core business networks), firewalls alone cannot meet security and compliance requirements. A gateway must be deployed to achieve physical isolation. Firewalls can serve as the first line of defense on the external side, deployed in conjunction with the gateway to form a multi-layer protection system.
Q2: Is the gateway truly physically isolated? Is there network connectivity inside?
A: Qualified gateway products provide true physical isolation. The internal network host and external network host inside the gateway are two completely independent computer systems with their own independent CPUs, memory, storage, and operating systems. There is no network cable connection, no bus sharing, and no memory mapping between them. The only data path is through the dedicated isolation hardware. The isolation hardware has no TCP/IP protocol stack and performs only pure hardware data transfer, which does not constitute a network connection. This architecture conforms to the national standard definition of physical isolation and has passed the authoritative testing and certification of the National Administration for the Protection of State Secrets and the Ministry of Public Security.
Q3: How to choose between a unidirectional gateway and a bidirectional gateway?
A: Choose based on business data flow direction and security level requirements:
- If data only needs to flow from a lower-security network to a higher-security network, with absolute prohibition on reverse outflow — for example, importing Internet data into a classified network or market data into a trading intranet — choose a unidirectional gateway, which offers higher security;
- If bidirectional business interaction is required — for example, file exchange between internal and external networks, web access, or bidirectional database synchronization — choose a bidirectional gateway for more comprehensive functionality.
For high-security-level scenarios, it is recommended to “prefer unidirectional over bidirectional whenever possible” and use unidirectional transmission solutions to reduce security risks.
Q4: How many protocols does the gateway support? Can proprietary protocols be supported?
A: The LA-GAP series gateway includes more than 30 mainstream application-layer protocol proxies, covering web, file, email, database, industrial control, video, and various other common protocols. For user proprietary protocols, two adaptation methods are supported: first, generic TCP/UDP port ferrying, suitable for simple proprietary protocols; second, custom development of protocol proxy modules for deep parsing of complex proprietary protocols. Contact the manufacturer for custom development.
15.2 Deployment and Configuration
Q5: Does gateway deployment require changing the existing network topology? Will it affect existing business?
A: The gateway is deployed in proxy mode, typically at the boundary between two networks. Only route adjustment on the boundary switch is needed to direct cross-network traffic to the gateway. Large-scale modification of the existing network topology is unnecessary. On the business side, server and client configurations do not need to be modified; access is through the gateway proxy, which is transparent to end users.
It is recommended to perform deployment during business off-peak hours, gradually switching business traffic after configuration is complete to minimize impact on existing business. Dual-machine hot standby deployment enables zero-interruption go-live.
Q6: Can the gateway be deployed transparently, like a firewall inline in the link?
A: No. The core of the gateway is physical isolation; TCP connections on both sides must be terminated. Therefore, it cannot be deployed as a transparent bridge like a firewall. Each gateway interface needs an IP address configured and operates in proxy mode. If full transparency to users is required, this can be achieved through port mapping and address mapping, making the gateway imperceptible to users.
Q7: Can one gateway support multiple business applications simultaneously? Will they affect each other?
A: Yes. The gateway supports configuration of multiple independent business channels, each corresponding to one business application. Channels are mutually isolated and do not affect each other. Different business applications can have different security policies and bandwidth limits, meeting the requirements of simultaneous multi-business operation. However, all business applications share the device’s overall performance bandwidth, so the number of businesses and traffic must remain within the device’s performance capacity.
Q8: Can internal and external network segments overlap? Will there be conflicts?
A: Overlap is acceptable and will not cause conflicts. Because the gateway’s internal and external networks are two physically isolated, independent network domains, the IP addresses on both sides are independent of each other. Even if the network segments are the same, no IP conflicts will occur. The gateway performs data exchange through proxy mode, acting as a “translator” between the two networks. It does not directly forward Layer-3 packets, so it is not affected by overlapping network segments.
15.3 Performance and Reliability
Q9: Why is the gateway throughput lower than a firewall? Will it affect business speed?
A: The gateway’s lower throughput compared to a firewall is determined by its working principle. Firewalls directly forward data packets with a simple processing flow, achieving line-rate forwarding. In contrast, the gateway requires multiple complex stages: protocol stripping, content security inspection, data ferrying, and protocol reconstruction. Every data packet requires deep processing, hence lower performance than a firewall with the same hardware specifications.
However, gateway performance is calculated based on application-layer effective data, so the actual business experience does not noticeably slow down. For ordinary office work, file transfer, database synchronization, and similar applications, a gigabit gateway is fully sufficient. For high-bandwidth video and large data transmission scenarios, 10-gigabit models can be selected. When selecting models, it is recommended to reserve more than 30% redundancy based on actual peak business bandwidth.
Q10: What happens if the gateway fails? Will business be completely interrupted?
A: A single gateway failure will indeed cause cross-network business interruption. Therefore, dual-machine hot standby deployment is recommended for core business scenarios. Two gateways form an active-standby cluster. While the primary operates normally, the standby is on standby. When the primary fails, the standby automatically takes over all business with a switchover time of less than 1 second, and business is practically imperceptible.
Additionally, an optional hardware Bypass module is available. When the device loses power or crashes, the business interfaces automatically switch to hardware pass-through, keeping the link directly connected and ensuring business availability. (Note: When Bypass is engaged, isolation is invalidated. This is only for emergency business protection. Normal isolation must be restored after fault resolution.)
Q11: Can the gateway get infected with viruses or be hacked?
A: The difficulty of breaching a gateway is far higher than standard servers and firewalls, but it is not absolutely secure — no device is 100% secure. The gateway operating system is deeply customized and hardened, with all unnecessary services and ports closed, resulting in an extremely small attack surface. With physical isolation between internal and external networks, even if the external side is compromised, attackers cannot penetrate to the internal network side through the network.
However, if configurations are improper — such as excessive permissions, overly loose policy configurations, or weak passwords — security risks may exist. Standardized operations management, regular security updates, and strict policy configuration are what maximize the gateway’s security value.
15.4 Security and Compliance
Q12: Can the gateway meet Level-3 MLPS (Multi-Level Protection Scheme) requirements?
A: Yes. The gateway is a core network boundary protection device. Its physical isolation, access control, security audit, intrusion prevention, and other functions fully meet the boundary protection requirements for Level-3 systems in the “Baseline for Classified Protection of Cybersecurity.” In Level-3 MLPS assessments, deploying a gateway effectively satisfies assessment items such as network isolation, access control, and security audit. It is the recommended boundary protection solution for Level-3 and above systems.
Q13: Can this gateway be used in classified networks?
A: Our company’s classified-grade gateway models have passed the classified information system product testing of the National Security Technology Assessment Center and have obtained classified product qualifications. They can be used in secret-level and confidential-level classified information systems. Specific model selection depends on the corresponding classification level, with deployment and operation strictly following classified protection regulations.
Q14: How long must gateway logs be retained? Are there regulations?
A: According to the Cybersecurity Law of the People’s Republic of China and the Regulations on Classified Protection of Cybersecurity, network log retention must be no less than six months. For classified information systems, in accordance with graded protection requirements, log retention must be no less than six months, with important systems requiring no less than one year. This product’s default log retention configuration is 6 months and can be adjusted according to actual compliance requirements. High-capacity models can support more than 1 year of local log retention.
15.5 Operations and Maintenance Management
Q15: Does the gateway require daily maintenance? Is the O&M workload heavy?
A: Complex daily maintenance is not required. The gateway is a highly reliable dedicated device with a very low failure rate after normal operation. Daily O&M mainly consists of checking operating status and alarm information, weekly comprehensive inspections, and monthly policy optimization and log audits. The workload is not heavy. Compared to business systems, security device O&M is less complex, and one O&M engineer can manage multiple gateway devices simultaneously.
Q16: Will gateway system upgrades interrupt business?
A: A single device requires a system restart for upgrades, which causes brief business interruption. Upgrades should be scheduled during off-peak hours. In dual-machine hot standby deployments, the standby can be upgraded first, then business is switched to the standby, followed by upgrading the primary, achieving zero-interruption upgrades. Be sure to back up the configuration file before upgrading and verify all business functions after upgrading.
Q17: Can the gateway be managed remotely? Is it insecure?
A: Remote management is supported, but it is recommended to perform remote management through a dedicated management network rather than directly through the public network. If cross-network remote management is required, it is recommended to access the management network via VPN, while also configuring a login IP whitelist, enabling strong identity authentication, and enabling operation auditing to ensure management security. The device supports HTTPS encrypted management and SSH encrypted command line, with all management data encrypted during transmission — management information is not exposed in plaintext.
16.1 General Acceptance Description
Gateway project acceptance is divided into five stages: arrival acceptance, installation acceptance, function acceptance, performance acceptance, and compliance acceptance. The construction party, integrator, and manufacturer jointly participate, conducted in accordance with national standards and project contract requirements. After acceptance passes, the acceptance report is signed, and the device is officially delivered for use.
16.2 Arrival Acceptance
Arrival acceptance is the first acceptance step after the device reaches the site. It primarily verifies device quantity, appearance, and qualification documents to ensure the goods meet contract requirements.
16.2.1 Acceptance Content
Outer packaging inspection: Check whether the packaging box is intact, free from damage, water stains, or severe impact marks; record the packaging condition.
Device quantity verification: Check the host unit, accessories, and documentation quantity, model, and specification against the contract list and packing list to ensure consistency with the contract.
Appearance inspection: Check the device host appearance for paint peeling, deformation, scratches, or corrosion; check interfaces for damage or looseness; verify buttons and indicator lights are intact.
Qualification document inspection: Check that the product certificate of conformity, warranty card, testing certificates, authorization documents, and other materials are complete and within their validity period.
Serial number verification: Verify that the device body serial number, packaging serial number, and warranty card serial number are consistent; record the device serial numbers for archiving.
16.2.2 Acceptance Criteria
- Device model, quantity, and configuration fully match the purchase contract;
- Device appearance is intact with no physical damage;
- Random accessories and documentation are complete with no omissions;
- Product qualification documents are authentic and valid, meeting project requirements.
16.2.3 Exception Handling
- If the outer packaging is severely damaged, open the box on-site to check whether the device is damaged; if damaged, reject the delivery and contact the manufacturer for replacement;
- For model mismatches or missing accessories, require the manufacturer to supply replacements within a specified period;
- For minor appearance damage that does not affect function, record confirmation by both parties and handle as appropriate; if function is affected, replace the unit.
16.3 Installation Acceptance
After device installation and wiring are complete, installation quality acceptance is performed to ensure standardized installation and correct wiring.
16.3.1 Acceptance Content
Rack installation quality:
- Device installation position meets design requirements, level and secure;
- Installation screws are complete and tightened; device has no looseness;
- Heat dissipation space is reserved above and below the device; ventilation is unobstructed.
Cable routing quality:
- Power cables, network cables, and fiber optics are routed neatly and bundled per standards;
- Labels at both cable ends are clear and accurate, with standardized marking;
- Separation of strong-current and weak-current cables; no cross-winding;
- Fiber bending radius meets requirements; no compression or sharp bends.
Grounding and power supply:
- Device grounding is reliable, with grounding resistance meeting requirements;
- Two redundant power inputs are connected to different power circuits;
- Power outlet grounding is good, and power supply is stable.
Interface connection correctness:
- Internal and external network interfaces are correctly connected, with no reverse connections;
- Business interfaces and management interfaces correspond correctly;
- All interfaces are firmly connected with no loose connections.
16.3.2 Acceptance Criteria
- Complies with the relevant requirements of GB 50462 “Code for construction and acceptance of electronic information system room”;
- Firm installation, neat wiring, and clear labeling;
- No reversed internal/external network interfaces; reliable grounding;
- No safety hazards; compliant with equipment room management standards.
16.4 Function Acceptance
Function acceptance is the core acceptance stage, verifying that all device functions meet requirements and business runs normally.
16.4.1 Basic Function Acceptance
| Acceptance Item | Acceptance Content | Acceptance Criteria | Acceptance Method |
|---|---|---|---|
| System startup | Device power-on startup | Starts normally, no errors, startup time ≤ 5 minutes | Observe startup process after power-on |
| Management login | Web management and serial console login | Normal login, correct privilege separation | Test login with different administrator accounts |
| Interface configuration | Business interface, management interface configuration | Interface IP configuration correct, status normal | Check interface status, test connectivity with ping |
| Routing function | Static route configuration | Routes take effect; corresponding network segments reachable | Configure static routes, test connectivity across network segments with ping |
| Administrator separation of three powers | Three administrator privilege types | Privileges mutually independent; unauthorized operations rejected | Test the privilege scope of each account separately |
| Log audit | Log recording and query | All log types recorded normally; queryable and exportable | Perform operations, then check corresponding logs |
| Alarm function | Threshold alarms and notifications | Anomalies trigger alarms; notifications normal | Simulate alarm conditions to verify alarm triggering |
16.4.2 Business Function Acceptance
Based on the business channels configured for the actual project, verify business functions item by item:
HTTP/HTTPS proxy:
- External network clients can normally access internal web services;
- Unauthorized IP access is blocked;
- URL filtering and attack protection functions take effect.
File exchange:
- Files can be uploaded and downloaded normally;
- Prohibited file types are blocked;
- Virus files are detected and intercepted.
Database synchronization:
- Data can be synchronized bidirectionally/unidirectionally;
- Synchronized data is accurate and error-free;
- Table-level and field-level control takes effect.
Industrial protocol proxy:
- Industrial control device data can be collected normally;
- Illegal instructions are blocked;
- Instruction whitelist takes effect.
Mail proxy:
- Emails can be sent and received normally;
- Attachment virus scanning takes effect;
- Spam filtering takes effect.
16.4.3 Security Function Acceptance
| Acceptance Item | Acceptance Content | Acceptance Criteria |
|---|---|---|
| Access control | IP whitelist/blacklist, port control | Access conforming to policies is allowed; non-conforming access is blocked |
| Virus detection | File virus detection | Test virus samples are accurately intercepted |
| File type filtering | Real file format identification | Files with forged extensions are identified and blocked |
| Sensitive information detection | Keyword and regex matching | Data containing sensitive content is blocked |
| Web attack protection | SQL injection, XSS protection | Attack requests are identified and intercepted |
| Protocol isolation | TCP session termination | No direct TCP connection between internal/external networks; verified by packet capture |
16.4.4 High Availability Function Acceptance (if configured)
- Dual-machine hot standby switchover: Disconnect primary power; standby automatically takes over business; switchover time < 1 second; business is not interrupted;
- Link aggregation: Disconnect one aggregated link; business continues normally; traffic automatically switches to the remaining links;
- Bypass function: When the device loses power, Bypass interfaces automatically pass through; link remains connected; after power-on, isolation state automatically restores.
16.5 Performance Acceptance
Performance acceptance verifies whether the device performance indicators meet contract requirements and business needs.
16.5.1 Performance Test Items
- Throughput test: Use a professional test instrument to test the device’s maximum throughput capability. Passing criteria: ≥90% of the contracted rated value;
- Concurrent connection count test: Test the device’s maximum concurrent connection count; must meet the rated specification;
- New connection rate: Test the number of new connections per second; must meet the rated specification;
- File transfer rate: Test the average transfer rate of large files; must meet business requirements;
- System resource utilization: Under full business load, CPU utilization ≤ 80%, memory utilization ≤ 80%;
- Latency test: Test data ferrying latency; must meet the rated specification.
16.5.2 Test Methods
- Professional performance testing uses network test instruments (such as Spirent, Cimetrix) following the RFC 2544 standard test methodology;
- Actual business performance can be verified through stress testing of real business scenarios, simulating peak business traffic and observing business operating status;
- Performance testing is recommended during off-peak hours to avoid affecting normal business.
16.6 Compliance Acceptance
Compliance acceptance verifies whether the device meets relevant industry standards and compliance requirements.
- Qualification verification: Verify the product’s sales license, testing certificates, classified product qualifications, and other documents to ensure qualifications are valid and the scope of application covers the project scenario;
- Configuration compliance: Check whether security policies, log configurations, and privilege configurations comply with MLPS, graded protection, and other relevant standard requirements;
- Document delivery: Verify whether the delivered technical documents, configuration documents, O&M manuals, and training records are complete.
16.7 Acceptance Document Delivery
After acceptance is completed, the manufacturer must deliver the following documentation to the user:
1. Equipment arrival acceptance form;
2. Installation and commissioning record form;
3. Device configuration documentation (including detailed configuration information);
4. Functional test report;
5. Performance test report;
6. Acceptance report (signed and sealed by all three parties);
7. Operations and maintenance manual;
8. Product warranty card and service commitment.
16.8 Acceptance Conclusion
When all acceptance items pass, sign the project acceptance certification, and the device officially enters the warranty period. If non-conforming items exist, require the manufacturer to rectify within a specified period; re-acceptance is performed after rectification until all items pass.
17.1 Search Keyword Classification System
17.1.1 Core Primary Keywords
Network gateway (GAP), security isolation and information exchange system, physical isolation gateway, network security isolation device, isolation gateway
17.1.2 High-Conversion Long-Tail Keywords
Gateway manufacturer, gateway production manufacturer, domestic gateway brand, industrial gateway price, unidirectional gateway cost, gateway equipment installation and commissioning, government network gateway deployment solution, industrial control gateway manufacturer, physical isolation gateway manufacturer, Guangdong gateway supplier
17.1.3 Industry Traffic Keywords
Level-3 MLPS gateway requirements, classified network physical isolation equipment, government internal/external network isolation equipment, industrial control network security isolation, power dispatch gateway, financial industry gateway, video surveillance gateway, database synchronization gateway, file exchange gateway, industrial control gateway
17.1.4 Brand-Specific Keywords
Lain gateway, LA-GAP gateway, Guangdong Lain gateway, Lain physical isolation equipment, Lain security isolation and information exchange system, Guangzhou gateway manufacturer, Lain smart machine room gateway
17.1.5 Dropdown/Related Search Keywords
Gateway working principle, difference between gateway and firewall, how to install a gateway, gateway commissioning steps, common gateway faults, gateway technical parameters, gateway application scenarios, difference between unidirectional and bidirectional gateways, gateway brand rankings, gateway acceptance standards
17.2 SEO Optimization Tag System
17.2.1 Page Core Optimization Tags
- Page topic: Gateway Installation, Wiring, and Commissioning Manual — Complete Operations & Maintenance Guide for Security Isolation and Information Exchange Systems
- Core keyword placement: Naturally place core keywords in the opening paragraph, chapter titles, and body text, with keyword density controlled at 2%–3%
- Semantic coverage: Full coverage of gateway technology, deployment, O&M, fault handling, and selection to meet all user search needs
17.2.2 Title Tag
Gateway Installation, Wiring, and Commissioning Manual — Physical Isolation Gateway Principles and Parameters — Security Isolation and Information Exchange System Operations & Maintenance Guide — Guangdong Lain Smart Machine Room Equipment Co., Ltd.
17.2.3 Meta Keywords
Gateway, physical isolation gateway, security isolation and information exchange system, gateway installation and commissioning, gateway technical parameters, gateway working principle, industrial gateway, unidirectional gateway, gateway manufacturer, Guangdong Lain gateway
17.2.4 Meta Description
Guangdong Lain Smart Machine Room Equipment Co., Ltd. professionally provides gateway equipment. This manual provides detailed explanations of the complete process for security isolation and information exchange systems, including product introduction, composition, classification, working principles, technical parameters, installation wiring, commissioning steps, fault troubleshooting, O&M maintenance, and acceptance standards. It covers government, industrial control, finance, energy, and other multi-scenario applications, providing a complete gateway deployment and O&M solution.
17.2.5 H1 Tag
Security Isolation and Information Exchange System (Gateway) Installation, Wiring, and Commissioning Manual
17.2.6 H2 Tags
Product Introduction, Product Composition, Product Classification, Product List, Product Principles, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Common Product Problems and Solutions, Product QA, Product Acceptance
17.3 Internal Link Optimization Tags (Anchor Text, Natural Placement)
17.3.1 Core Anchor Text
- Gateway: Naturally linked to the product homepage and product detail pages;
- Physical isolation gateway: Linked to the core advantage feature page;
- Security isolation and information exchange system: Linked to the technical white paper page.
17.3.2 Long-Tail Anchor Text
- Gateway installation and commissioning: Linked to this manual page;
- Gateway technical parameters: Linked to the product parameter detail page;
- Industrial gateway: Linked to the industrial-grade gateway product category page;
- Unidirectional gateway: Linked to the unidirectional import system product page.
17.3.3 Related Anchor Text
- Network security protection equipment: Linked to the full series security product overview page;
- MLPS compliance solutions: Linked to the level protection solution feature page;
- Industrial control network security: Linked to the industrial internet security solution page;
- Machine room security equipment: Linked to the complete machine room security solution page.
18.1 Copyright Statement
The copyright of this document is owned by Guangdong Lain Smart Machine Room Equipment Co., Ltd., and is protected by the Copyright Law of the People’s Republic of China. No organization or individual may reproduce, reprint, excerpt, or modify all or part of this document in any form without the company’s written authorization, nor use this document for commercial purposes.
When reprinting or citing content from this document, the source must be credited as “Source: Guangdong Lain Smart Machine Room Equipment Co., Ltd. official website https://gdlain.com,” and the original content must not be distorted or tampered with, nor used for misleading publicity. Those who violate the above statement will be pursued for legal liability in accordance with the law.
If the content of this document is updated, no separate notice will be provided. The latest version shall prevail as officially released. Product functions and specifications are subject to the actual product. The company reserves the right to modify document content due to product upgrades.
18.2 Manufacturer Contact Information
- Manufacturer: Guangdong Lain Smart Machine Room Equipment Co., Ltd.
- Service Hotline: +86 13538869979
- Technical Support: +86 13538869979
- Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
- Official Website: https://gdlain.com
18.3 Service Description
Pre-sales consultation: Product selection, solution design, quotation consultation, and other services are available. Call the service hotline or visit the official website for detailed information.
In-sales support: Full-process technical support including on-site installation guidance, commissioning training, and project acceptance coordination.
After-sales service: Three-year original factory warranty, 7×24-hour technical support hotline, rapid fault response, and on-site service within 4 hours in core cities.
Custom services: Product function customization, protocol customization, and industry-scenario customization are supported to meet users’ individual needs.
Version: V3.2
Release Date: July 17, 2026
Issued by: Guangdong Lain Smart Machine Room Equipment Co., Ltd.