Table of Contents
ToggleProduct Overview
The Server Room Fire Linkage Monitoring System is an integrated fire early-warning and linkage disposal solution designed for server room environments. It combines multiple fire detection technologies including smoke, heat, gas, and flame detection, along with fire equipment linkage control, video verification, and alarm notification. The system enables early fire detection, rapid alerting, and swift disposal while automatically coordinating access control, HVAC, and power systems for comprehensive fire linkage actions. This minimizes fire losses and safeguards both personnel and equipment. It complies with national fire protection standards such as GB 50116 and GB 50174, making it a core component of server room fire safety infrastructure.
Product Positioning
This system serves as the ultimate safeguard for server room fire safety. It is positioned for enterprise IT rooms, data centers, telecom facilities, industrial server rooms, and archive repositories that require reliable fire detection and rapid response. It is designed to meet national fire protection codes while providing advanced features like early warning and minimized false alarms, making it ideal for high-value, high-density environments.
Core Value
- Early Fire Warning: Multi-detector fusion accurately identifies early fire risks, with warning times up to 30% earlier than traditional smoke detectors.
- Rapid Linkage Disposal: Automatically activates fire suppression equipment, cuts non-fire power, shuts off air conditioning, and opens access control for evacuation upon fire confirmation.
- False Alarm Reduction: Multi-parameter cross-validation and a 30-second delay confirmation mechanism reduce false alarms from single detectors, avoiding business losses from accidental discharge or power outages.
- Compliance and Acceptance: Aligns with national fire codes and server room standards, facilitating fire acceptance and compliant operations.
Product Highlights
- Multi-Detector Fusion: Supports smoke, heat, aspirating, flame, and gas detectors for comprehensive fire verification.
- Multi-Level Linkage Logic: Pre-alarm and fire alarm levels with manual verification during pre-alarm and automatic linkage during fire alarm, complying with fire codes.
- Full-Scene Linkage Control: Integrates with gas suppression, aerosol suppression, fire pumps, fire doors, access control, power, and air conditioning systems.
- Visualized Fire Management: Electronic fire maps, device status visualization, and full event logging for clear management and traceability.
System Composition
The system consists of four layers: fire detection layer, linkage control layer, management platform layer, and suppression execution layer.
- Fire Detection Layer: Includes point-type smoke detectors, heat detectors, aspirating smoke detectors, flame detectors, and gas detectors deployed across the server room to collect fire characteristic signals in real time.
- Linkage Control Layer: Fire alarm controllers, linkage control modules, and input/output modules handle fire determination, logic operations, and linkage command output. They support local linkage execution even when the network is disconnected.
- Management Platform Layer: The fire monitoring management platform centrally displays fire equipment status, alarm information, and event records, supporting remote monitoring and management.
- Suppression Execution Layer: Gas suppression equipment, aerosol suppression devices, fire shutters, non-fire power cutting modules, and access control release modules receive commands to execute fire actions.
Core Technical Parameters
| Parameter | Specification |
| ———– | ————— |
| Detector response time | ≤10s |
| Linkage response time | ≤3s |
| System capacity | ≥2000 detection points, ≥512 linkage points per controller |
| Alarm methods | Sound/light, SMS, phone, email, platform pop-up |
| Power supply | AC 220V main + DC 24V backup, backup ≥8 hours |
| Working temperature | -10℃~55℃ |
| Compatibility | GB 25506 fire linkage standard protocol |
| MTBF | ≥100000 hours |
Core Advantages
1. Material Advantages
Detector housings use flame-retardant PC material (UL94-V0) that produces no toxic gases at high temperatures. Core components are industrial-grade wide-temperature devices. Fire-resistant cables comply with GB 19666, ensuring communication during fire emergencies.
2. Craftsmanship Advantages
Fire controllers feature industrial-grade motherboards with SMT soldering and conformal coating. Detectors undergo smoke simulation, high/low-temperature, and EMC tests to ensure accuracy and stability. Products are assembled and tested strictly per fire protection production standards.
3. Customization Advantages
System solutions, linkage logic, and networking can be customized based on server room area, fire zones, and suppression methods. Integration with DCIM, video surveillance, and building fire systems is supported via custom development.
4. Cost Advantages
Integrated design reduces intermediate equipment and installation costs. System compatibility with major detector and suppression brands allows reuse of existing equipment, lowering retrofit costs. Accurate early warning reduces fire losses and potential risk costs.
5. Quality Advantages
Core fire products hold national CCCF certification, complying with GB 50116. Strict quality control includes full-function fire simulation testing before shipment.
Product Categories
- Standard Server Room Fire Linkage Alarm System: Suitable for small and medium server rooms, with point-type smoke/heat detection and basic linkage functions meeting conventional fire protection requirements.
- Aspirating Very Early Warning Fire System: Designed for high-density, high-value data centers, providing extremely early smoke detection for advanced warning.
- Cabinet-Level Fire Linkage System: Configured for individual racks or micro-modules, integrating detection and suppression linkage for plug-and-play protection of high-value local assets.
- Multi-System Integrated Fire Linkage Platform: Merges fire, environment, video, and access control into one linkage platform, ideal for comprehensive management of large data centers.
- Wireless Fire Alarm System: Wireless smoke detectors plus gateways, perfect for retrofit projects where cabling is not feasible or desired.
Material & Process Analysis
Material Details
- Detector Housing: Flame-retardant PC engineering plastic, UL94-V0 rated, high temperature resistance, anti-aging, meeting fire protection material requirements.
- Fire Controller Enclosure: 1.5mm thick cold-rolled steel, electrostatic powder coating, 19-inch rack-mount design, corrosion-resistant and anti-interference.
- Fire Cables: NH-RVS fire-resistant twisted pair, copper core PVC insulated, B1 fire resistance rating, ensuring circuit integrity during fires.
- Detection Maze: Insect-proof mesh plus precision optical maze design, preventing insects and dust, reducing false alarms, and improving detection accuracy.
Key Processes
- Optical Maze Design: Smoke detectors use a precision optical maze structure to accurately scatter smoke particles while shielding external light interference, reducing false alarm rates.
- Fire Linkage Logic Programming: Custom linkage logic based on national fire codes, supporting multi-zone and multi-level linkage strategy programming for different scenarios.
- Fire-Resistant Protection: Core control modules are thermally insulated to ensure the system continues operating and outputs linkage commands during the initial fire phase.
- Standardized Production: Strict assembly and testing per fire product production standards, including smoke box simulation tests for every unit.
Safety Certifications
Core fire products hold the national compulsory fire product 3C certification (CCCF). The system complies with GB 50116 (Code for Design of Automatic Fire Alarm System), GB 50174 (Code for Design of Data Centers), GB 50370 (Code for Design of Gas Fire Suppression Systems), and ISO9001 quality management system certification.
Stock & Delivery Details
- Standard point-type smoke detectors, heat detectors, and fire controllers are regularly stocked and ship within 24 hours after ordering.
- Standard fire linkage modules and accessories have sufficient inventory; up to 500 points per batch can be supplied from stock.
- Aspirating smoke detection systems and customized linkage solutions require configuration confirmation, with delivery in 7-15 days.
- All fire products come with CCCF certificates, certificates of conformity, and manuals, meeting fire acceptance requirements.
OEM/ODM Services
The system offers OEM/ODM services for fire systems, supporting brand labeling, custom packaging, firmware customization, and linkage logic customization. Strict confidentiality mechanisms are in place, including signed Non-Disclosure Agreements to protect client project information and technical solutions. Full-process outsourcing services include hardware labeling, system customization, and project support. The lead time for fire product OEM is 15-20 days, complying with fire product production standards.
Product SKU Attributes
| SKU Code | Product Name | Model | Suitable Scenario | Unit |
| ———- | ————– | ——- | ——————- | —— |
| KTZ-XF-001 | Standard Fire Linkage Alarm System | KTZ-XF-C01 | Small/medium server room | Set |
| KTZ-XF-002 | Aspirating Very Early Warning System | KTZ-XF-J01 | Large data center | Set |
| KTZ-XF-003 | Cabinet-Level Fire Linkage Kit | KTZ-XF-G01 | Rack/micro-module | Set |
| KTZ-XF-004 | Fire Linkage Management Platform | KTZ-XF-PL | Centralized control | Set |
| KTZ-XF-005 | Wireless Fire Alarm Kit | KTZ-XF-W01 | Retrofitted server room | Set |
Specifications & Technical Parameters
| Item | Parameter |
| —— | ———– |
| Product Name | Server Room Fire Linkage Monitoring System |
| Model Series | KTZ-XF Series |
| Detection Type | Smoke, heat, aspirating, flame, gas (selectable) |
| Capacity per Controller | 2000 detection points / 512 linkage points |
| Linkage Response Time | ≤3s |
| Fire Confirmation Delay | 0-60s configurable, default 30s |
| Backup Power Duration | ≥8 hours |
| Alarm Methods | Sound/light, SMS, phone, email, APP |
| Supply Voltage | AC 220V±15% + DC 24V backup |
| Working Temperature | -10℃~55℃ |
| Working Humidity | 10%~90%RH, non-condensing |
| Installation Method | Ceiling, wall, or rack mount |
| Communication Protocol | National standard fire protocol, Modbus, API interface |
| Protection Rating | IP30 (indoor type) |
| Certification | CCCF fire certification, ISO9001 |
| MTBF | ≥100000 hours |
Application Scenarios
- Enterprise Server Rooms: Fire alarm and linkage for various enterprise IT and server rooms.
- Data Centers: Very early fire warning and linkage disposal for large IDC, cloud, and financial data centers.
- Telecom Rooms: Fire monitoring and remote alarm for operator core rooms and base stations.
- Industrial Server Rooms: Fire safety control for power plants, rail transit, and factory automation rooms.
- Archive Repositories: Fire protection and compliance management for archive rooms and disaster recovery centers.
Customization Services
Customization Scope
- Solution Customization: Fire point layout and linkage plan based on fire zones, building structure, and equipment layout.
- Function Customization: Custom linkage logic, alarm levels, notification methods, and report styles.
- Integration Customization: Interface with environment monitoring, video, access control, and building fire systems.
- Appearance Customization: Device housing, silk-screen, and packaging tailored to brand needs.
Customization Process
- Requirement Communication: Understand server room conditions, fire code requirements, and customer needs.
- Solution Design: Provide fire design plan, point layout, and quotation within 3 working days.
- Contract Signing: Confirm solution and qualifications, sign contract, and pay advance.
- Production & Debugging: Manufacture per plan, pre-program linkage logic, and run simulation tests before shipment.
- Installation & Acceptance: On-site installation and commissioning, support fire acceptance, and deliver acceptance documents.
- After-Sales Support: Dedicated after-sales service, regular inspections, and compliant operation assurance.
Customization Advantages
- Professional fire technical team familiar with server room fire codes, ensuring compliant and acceptable solutions.
- Independent hardware and software R&D, allowing deep customization of linkage logic for complex scenarios.
- Extensive experience in server room fire projects with deep understanding of typical pain points.
- Full support during fire acceptance with complete qualification documents to guarantee success.
Success Case
Client: A municipal bank’s core server room
Highlights: Deployed an aspirating very early warning fire linkage system in an 800㎡ core server room, including 12 aspirating sampling pipe sets, 68 point-type detectors, and integration with heptafluoropropane (FM200) gas suppression, access control, non-fire power, and HVAC systems. The system achieved very early smoke detection, identifying fire conditions 40 minutes earlier than conventional systems. Multi-detector cross-validation plus a 30-second delay confirmation reduced false alarm rate to below 0.1%. Upon fire confirmation, the suppression sequence automatically executed, with FM200 discharge time ≤8 seconds, meeting gas suppression codes. The system passed fire acceptance and has operated flawlessly for 5 years, ensuring the security of banking business systems.
Procurement Service Guarantees
Supply Guarantee
Fire products are maintained in safety stock with standard models available for immediate shipment. Bulk orders receive priority scheduling to meet project deadlines. Core components are compliantly sourced with complete qualification documentation.
Quality Guarantee
All fire products carry CCCF certification and undergo full-function smoke box testing before shipment. Strict quality control ensures every device meets national fire standards.
Logistics Guarantee
Professional shock-resistant and fire-resistant packaging, combined with compliant logistics partners, ensures product integrity during transport. Bulk orders use dedicated vehicles with full tracking.
After-Sales Guarantee
2-year warranty on the entire system, 3-year warranty on fire detectors. 7×24 technical support, regular follow-up inspections, and annual fire inspection support to maintain ongoing compliance.
Invoice Guarantee
13% VAT special invoices are available, fully compliant, with product qualification copies included, meeting financial and acceptance requirements.
Conversion Module
Call-to-Action
- Request a fire protection solution
- Schedule an on-site survey
- Apply for qualification documents
- Get a quotation
Contact Information
- Phone: 13538869979 / 13538869979
- Website: https://gdlain.com
- Address: Chaotian Industrial Park, No.5 Huashan Road, Shilou Town, Panyu District, Guangzhou
Promotional Notes
New customers receive a free server room fire compliance assessment and solution design. Bulk purchases enjoy discounts. Full support for fire acceptance is provided.
FAQ
Q: Can this system pass fire acceptance?
A: Yes, core products have CCCF certification, and the system design complies with GB 50116, supporting fire acceptance.
Q: Will it cause false alarms and accidental gas discharge?
A: The system supports multi-detector cross-validation and multi-level alarms. Pre-alarm requires manual verification, and a default 30-second delay before suppression significantly reduces false discharge risks.
Q: Can it integrate with our existing fire system?
A: Yes, it supports national standard fire protocols and can interface with existing building fire systems for zoned control and centralized monitoring.
Q: What suppression method is suitable for server rooms?
A: Clean agents such as heptafluoropropane (FM200) or IG541 are common, or aerosol suppression. These cause no secondary damage to equipment, and we provide integrated solutions.
Fault Handling & Maintenance
Common Faults & Solutions
- Detector Fault: Check if the detector is loose or dusty; clean the detector filter and reset the controller for testing.
- False Alarm: Check for large amounts of dust or moisture interference in the detection area; adjust detector sensitivity and clean environmental interference sources.
- Linkage Not Operating: Check the linkage module’s power supply and wiring, confirm the linkage logic configuration, and manually test the linkage output.
- Backup Power Fault: Check backup battery voltage and wiring; replace aging batteries promptly.
Routine Maintenance
- Monthly: Check system operation status and review any fault or alarm messages.
- Quarterly: Clean detector surfaces and filters to prevent dust accumulation affecting detection sensitivity.
- Semi-annually: Perform fire linkage tests to verify detector and linked device functionality.
- Annually: Conduct comprehensive fire detection, replace aged batteries, and issue a test report.
Factory Strength & After-Sales Service
Factory Strength
Certified with fire product production qualification and professional production lines, equipped with smoke box testing laboratories and linkage test platforms. Products pass national fire 3C certification. The team has over 10 years of server room fire project experience, serving thousands of government and enterprise server rooms, and providing end-to-end services from design and production to installation and acceptance.
After-Sales Service
- Warranty: 2-year warranty on the entire system, 3-year warranty on core components.
- Annual Inspection: Annual fire inspection services with test reports to support fire checks.
- Emergency Service: 7×24 emergency response with priority handling for fire faults.
- Upgrade Service: Lifetime free system feature upgrades and continuous linkage logic optimization.
Conclusion
The Server Room Fire Linkage Monitoring System forms the ultimate defense line for server room safety. Through precise fire detection and intelligent linkage handling, it minimizes fire risks and losses while ensuring compliance with fire codes. We deliver compliant products, professional solutions, and complete services to build reliable fire safety barriers for various industries.