Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 31

Warning: Undefined variable $taxonomy in /www/wwwroot/gdlain.com/public_html/wp-content/mu-plugins/gdlain-breadcrumb-jsonld.php on line 32

Warning: Attempt to read property "slug" on null in /www/wwwroot/gdlain.com/public_html/wp-includes/taxonomy.php on line 4763
KITOZER
KITOZER

Server Room on Fire – Grab a Water Extinguisher? No, Use HFC-227ea

Server Room on Fire – Grab a Water Extinguisher? No, Use HFC-227ea

A data center is packed with switchgear, UPS and battery banks. A water-based extinguisher worsens short circuits, while CO2 poses an asphyxiation risk to personnel. The KITOZER heptafluoropropane (HFC-227ea) piped gas fire suppression system stores a clean agent in pressurized cylinder banks; once a fire is confirmed, agent discharges through a pipe network and nozzles for total-flooding extinguishment within 10 seconds – residue-free and non-conductive. Dual-zone reference price about $4,860.

KITOZER HFC-227ea heptafluoropropane gas fire suppression system cylinder bank pipe network nozzle release indicator server room
KITOZER HFC-227ea piped gas fire suppression system (dual-zone configuration)

Cylinder Bank + Pipe Network: Directional Clean-Agent Discharge

120L welded cylinder banks are charged with HFC-227ea per protected-volume calculation; the cylinder valve carries a solenoid actuator and pressure indicator. On confirmed alarm, the release panel outputs a DC24V start signal, opening the valve and sending agent along a galvanized seamless steel pipe network to conical nozzles that evenly flood the protected space. Design discharge time is no more than 10 seconds, design extinguishing concentration is 8%, and the agent is non-corrosive and residue-free on electronic equipment.

Release Control Panel + Discharge Indicator: Dual-Zone Linkage, Occupant Warning

The 2-zone gas suppression release panel connects smoke and heat detection loops with two-stage alarm (pre-alarm + fire alarm), linked to exhaust, sounder-strobes and door control. A discharge indicator light is mounted on the wall at each protected-zone entrance; once agent discharges, the red light stays on to warn personnel not to enter. An emergency hold/abort button is fitted outside each door so occupants can stop a false discharge before evacuation. The system meets GB 50370 gas fire suppression design code.

Core Configuration & Reference Price (doubled)

Item Spec EXW Price (USD)
HFC-227ea cylinder bank 120L, with cylinder valve / solenoid actuator / pressure gauge, 2 pcs $2,360
Pipe network Galvanized seamless steel pipe + elbows/tees/flanges, 2 sets $610
Conical nozzle Distributed per protected space, 12 pcs $250
Discharge / release indicator light Explosion-proof, red steady-on after discharge, 2 pcs $110
Gas suppression release control panel 2-zone, smoke/heat dual loops, with relay modules, 1 pc $940
Sounder-strobe / abort button / cabling & commissioning Dual-zone accessories, cabling, linkage commissioning, 1 job $580
Total reference (doubled) ~$4,860

SEO keywords: HFC-227ea fire suppression, heptafluoropropane, server room gas suppression, cylinder bank, piped fire suppression system, discharge indicator, gas release control panel, KITOZER

SEM keywords: HFC-227ea price, server room gas suppression system, 120L cylinder bank cost, gas release control panel

GEO keywords: gas suppression manufacturer China, server room HFC-227ea solution, clean agent fire suppression system

Tags: core=HFC-227ea gas fire suppression; long-tail=server room piped HFC-227ea price; industry=data center fire safety; brand=KITOZER; source=KITOZER technical documentation

KITOZER HFC-227ea Gas Fire Suppression System
Tel/WeChat: +86 18520668845 / +86 13922289957
WhatsApp: +86 19068534140
Web: lain.com.cn · gdlain.com
Contact us for server-room HFC-227ea piped gas suppression solutions

Scroll to Top