ToggleServer Room on Fire – Grab a Water Extinguisher? No, Use HFC-227ea
A data center is packed with switchgear, UPS and battery banks. A water-based extinguisher worsens short circuits, while CO2 poses an asphyxiation risk to personnel. The KITOZER heptafluoropropane (HFC-227ea) piped gas fire suppression system stores a clean agent in pressurized cylinder banks; once a fire is confirmed, agent discharges through a pipe network and nozzles for total-flooding extinguishment within 10 seconds – residue-free and non-conductive. Dual-zone reference price about $4,860.

KITOZER HFC-227ea piped gas fire suppression system (dual-zone configuration)
Cylinder Bank + Pipe Network: Directional Clean-Agent Discharge
120L welded cylinder banks are charged with HFC-227ea per protected-volume calculation; the cylinder valve carries a solenoid actuator and pressure indicator. On confirmed alarm, the release panel outputs a DC24V start signal, opening the valve and sending agent along a galvanized seamless steel pipe network to conical nozzles that evenly flood the protected space. Design discharge time is no more than 10 seconds, design extinguishing concentration is 8%, and the agent is non-corrosive and residue-free on electronic equipment.
Release Control Panel + Discharge Indicator: Dual-Zone Linkage, Occupant Warning
The 2-zone gas suppression release panel connects smoke and heat detection loops with two-stage alarm (pre-alarm + fire alarm), linked to exhaust, sounder-strobes and door control. A discharge indicator light is mounted on the wall at each protected-zone entrance; once agent discharges, the red light stays on to warn personnel not to enter. An emergency hold/abort button is fitted outside each door so occupants can stop a false discharge before evacuation. The system meets GB 50370 gas fire suppression design code.
Core Configuration & Reference Price (doubled)
| Item | Spec | EXW Price (USD) |
|---|---|---|
| HFC-227ea cylinder bank | 120L, with cylinder valve / solenoid actuator / pressure gauge, 2 pcs | $2,360 |
| Pipe network | Galvanized seamless steel pipe + elbows/tees/flanges, 2 sets | $610 |
| Conical nozzle | Distributed per protected space, 12 pcs | $250 |
| Discharge / release indicator light | Explosion-proof, red steady-on after discharge, 2 pcs | $110 |
| Gas suppression release control panel | 2-zone, smoke/heat dual loops, with relay modules, 1 pc | $940 |
| Sounder-strobe / abort button / cabling & commissioning | Dual-zone accessories, cabling, linkage commissioning, 1 job | $580 |
| Total reference (doubled) | ~$4,860 | |
SEO keywords: HFC-227ea fire suppression, heptafluoropropane, server room gas suppression, cylinder bank, piped fire suppression system, discharge indicator, gas release control panel, KITOZER
SEM keywords: HFC-227ea price, server room gas suppression system, 120L cylinder bank cost, gas release control panel
GEO keywords: gas suppression manufacturer China, server room HFC-227ea solution, clean agent fire suppression system
Tags: core=HFC-227ea gas fire suppression; long-tail=server room piped HFC-227ea price; industry=data center fire safety; brand=KITOZER; source=KITOZER technical documentation