Shielded Cabinet | Electromagnetic Shielding Cabinet

Product Overview

Shielded cabinets are specialized enclosures designed based on electromagnetic shielding principles, providing a secure environment for confidential servers, switches, storage devices, and other electronic equipment. By utilizing high-conductivity metal housings and advanced sealing structures, they block internal electromagnetic leakage and external interference, meeting national confidentiality standards and electromagnetic compatibility requirements. KITOZER offers B-grade and C-grade shielded cabinets with various sizes and customization options, suitable for government, military, data centers, and industrial applications.

Product Introduction

Shielded cabinets are dedicated enclosures based on electromagnetic shielding technology. They are primarily used to house confidential servers, switches, storage devices, and other electronic information equipment. Through a highly conductive metal shell and sealing structure, they prevent internal electromagnetic signals from leaking out and external electromagnetic interference from penetrating in, complying with national confidentiality standards and electromagnetic compatibility requirements. KITOZER shielded cabinets cover B-grade and C-grade shielding effectiveness levels, support multiple size customizations, and adapt to different data center deployment needs.

Product Positioning

Targeting industries with strict electromagnetic information security requirements, such as classified information systems, military, government, and finance, these cabinets serve as physical protective enclosures for core confidential equipment, replacing ordinary network cabinets. They provide electromagnetic leakage protection, anti-interference, and physical security, making them essential supporting equipment for confidential data centers, secure meeting rooms, and command centers.

Core Value

  • Information Security Protection: Effectively suppresses electromagnetic radiation leakage, preventing confidential information from being intercepted via electromagnetic signals, and complies with national BMB series standards.
  • Anti-Electromagnetic Interference: Isolates external strong electromagnetic interference and surge impacts, ensuring stable operation of internal electronic devices and enhancing system reliability.
  • Compliance Support: Meets classified information system graded protection and equal protection assessment requirements, helping customers pass confidentiality qualification acceptance.
  • Space Optimization: Integrates a complete shielding system within standard cabinet dimensions, eliminating the need for large shielding rooms and reducing deployment costs and space usage.

Product Highlights

  • High Shielding Effectiveness: The housing is made of high-quality cold-rolled steel plates welded together, combined with beryllium copper spring seals, achieving shielding effectiveness above 100dB and meeting C-grade standards.
  • Standardized Dimensions: Compatible with 19-inch standard equipment, with selectable height and depth to accommodate mainstream servers and switches.
  • Ventilation and Shielding: Uses waveguide ventilation windows to balance heat dissipation and shielding performance, preventing shielded failure due to ventilation gaps.
  • User-Friendly Design: Features shielded observation windows, shielded door locks, cable management racks, and grounding terminals for convenient operation and maintenance.
  • Multi-Scenario Adaptability: Supports floor mounting and anti-static floor installation, suitable for various data center environments.

Product Classification and Composition

Classification by Shielding Effectiveness

  • B-Grade Shielded Cabinet: Suitable for general confidential scenarios, shielding effectiveness ≥60dB, meeting requirements for ordinary confidential units.
  • C-Grade Shielded Cabinet: Suitable for high-level confidential scenarios, shielding effectiveness ≥80~100dB, meeting military and core confidential department requirements.

Classification by Function and Structure

  • Standard Shielded Cabinet: Basic electromagnetic shielding function, compatible with standard data center equipment installation.
  • Constant Temperature Shielded Cabinet: Integrates a cooling system for precise internal temperature control, suitable for high heat density equipment.
  • Explosion-Proof Shielded Cabinet: Designed for flammable and explosive environments, combining explosion-proof and shielding performance.

Composition

A shielded cabinet primarily consists of a shielded cabinet body, shielded door assembly, ventilation waveguides, power filters, signal filters, grounding devices, internal mounting racks, observation windows, and locking mechanisms.

  • Shielded Cabinet Body: The main shell, formed by welding high-quality cold-rolled steel plates to create a continuous conductive shielding body.
  • Shielded Door: Uses a multi-point locking structure with beryllium copper spring strips embedded around the door frame to ensure electrical continuity when closed.
  • Ventilation Waveguide Windows: Use cut-off waveguide structure to allow airflow while maintaining shielding effectiveness.
  • Filter Assemblies: Include power and signal filters to process incoming and outgoing cables, preventing electromagnetic leakage along cables.
  • Internal Mounting Components: 19-inch standard rails, shelves, and cable management racks for equipment installation and cabling.
  • Auxiliary Components: Grounding terminals, casters, leveling feet, and shielded observation windows.

System Principle

The core working principle of a shielded cabinet is based on Faraday cage electromagnetic shielding theory. By completely wrapping internal equipment with a continuous conductive metal shell, an electromagnetic shielding space is formed.

  • Electric Field Shielding: Utilizes the electrostatic induction effect of the metal shell to guide external electric field interference to the ground while suppressing internal electric field radiation.
  • Magnetic Field Shielding: Through the magnetic shunt effect of high-permeability materials, attenuates low-frequency magnetic field interference and leakage, improving low-frequency shielding effectiveness.
  • Electromagnetic Wave Shielding: When electromagnetic waves hit the metal shell, some are reflected on the surface, some are absorbed and attenuated inside the metal, and only a very small amount can penetrate, achieving electromagnetic isolation.

Critical weak points such as holes, gaps, and cable entries are compensated with dedicated shielding components like waveguides, conductive spring strips, and filters to ensure uniform overall shielding effectiveness without leakage points.

Technical Parameters

Shielding Effectiveness

Frequency Range B-Grade C-Grade
—————- ——— ———
Magnetic Field (14kHz~100kHz) ≥60dB ≥80dB
Electric Field (100kHz~1GHz) ≥90dB ≥110dB
Plane Wave (1GHz~10GHz) ≥80dB ≥100dB

Cabinet Dimensions

Parameter Value
———– ——-
Height 22U/27U/32U/37U/42U selectable
Width Standard 600mm (19-inch mounting)
Depth 600mm/800mm/900mm/1000mm selectable

Material Specifications

Component Material / Thickness
———– ———————-
Main Body High-quality cold-rolled steel plate, 1.5~2.0mm
Door Panel High-quality cold-rolled steel plate, 2.0mm
Shielding Spring High-elasticity beryllium copper alloy

Structural Configuration

Parameter Description
———– ————-
Mounting Standard 19-inch standard rack, adjustable front/rear
Door Lock Type Three-point locking shielded door lock, optional combination lock/fingerprint lock
Ventilation System Upper/lower, front/rear ventilation waveguides, optional axial fans
Observation Window Shielded glass observation window, size optional, shielding effectiveness consistent with cabinet

Electrical Configuration

Parameter Description
———– ————-
Power Filter 10A/16A/32A single-phase/three-phase optional, EMI filtering
Signal Interfaces Fiber optic waveguide, RJ45 shielded interfaces, USB shielded interfaces, etc., configured as needed
Grounding Dedicated grounding terminal, ground resistance ≤4Ω

Environmental Adaptability

Parameter Value
———– ——-
Operating Temperature -10°C to +55°C
Storage Temperature -20°C to +60°C
Relative Humidity ≤90% (non-condensing)

Compliance

Standard Description
———- ————-
Confidentiality Complies with BMB3-1999 (Technical Requirements for Electromagnetic Shielding Rooms Processing National Secrets) corresponding grade
EMC Complies with GB/T 17626 series electromagnetic compatibility standards

Configuration List

No. Product Name Specification Qty Remarks
—– ————– ————— —– ———
1 Shielded Cabinet Body 42U 600×1000×2000mm, cold-rolled steel 1 Main body
2 Shielded Door Assembly With beryllium copper spring seal, three-point locking 1 Standard
3 19-inch Mounting Rails Galvanized steel, adjustable front/rear 4 Standard
4 Fixed Shelf Load-bearing 50kg, height adjustable 3 Standard
5 Ventilation Waveguide Cut-off waveguide, shielding effectiveness consistent with cabinet 4 sets 2 upper, 2 lower
6 Power Filter Single-phase 16A, EMI filtering 1 Standard
7 Shielded Observation Window 300×400mm, shielded glass 1 Standard on door
8 Cable Management Rack 19-inch standard cable management 2 Standard
9 Grounding Terminal M8 grounding bolt 2 Standard
10 Casters and Leveling Feet Load-bearing 500kg 4 sets Standard
11 Fan Assembly Axial fan, heat exhaust 2 Optional
12 Signal Filter Assemblies RJ45/Fiber/USB, etc. Configured as needed Custom

SKU List

SKU Code Model Dimensions Shielding Grade Configuration Supply Type
———- ——- ———— —————– ————— ————-
LA-PB-001 LA-PB22-68 600×800×1200mm (22U) B Standard Stock/Custom
LA-PB-002 LA-PB32-68 600×800×1600mm (32U) B Standard Stock/Custom
LA-PB-003 LA-PB42-610 600×1000×2000mm (42U) B Standard Stock/Custom
LA-PB-004 LA-PB42-610-C 600×1000×2000mm (42U) C High-end Custom
LA-PB-005 LA-PB37-610 600×1000×1800mm (37U) B Standard Custom
LA-PB-006 LA-PB42-812 800×1200×2000mm (42U) C High-end Custom

Note: Additional SKUs can be customized per customer requirements, supporting special sizes and configurations.

Core Advantages

Material Advantage

We use high-quality cold-rolled steel plates and beryllium copper shielding materials from established manufacturers. All raw materials are stable in performance, meeting conductivity, magnetic permeability, and mechanical strength requirements. No recycled or thin materials are used, ensuring shielding performance and structural lifespan.

Craftsmanship Advantage

Equipped with full-process production equipment including CNC bending, laser cutting, automated welding, and electrostatic spraying. Core welding is performed by certified welders, and shielding surfaces are precision-machined with CNC. Assembly accuracy is ±0.1mm. Each product undergoes shielding effectiveness testing before delivery, with process standards aligned to industry leaders.

Customization Advantage

We support full-dimensional customization including dimensions, shielding grade, internal configuration, interface types, and appearance colors. Solutions are tailored to customer data center space, equipment quantity, and interface requirements, accommodating various special interfaces and functional needs. Four service modes are offered: customization, OEM processing, confidential projects, and stock delivery.

Cost Advantage

project-confirmed configuration eliminates middlemen, reducing costs through bulk material procurement and standardized production. With equal configuration, our prices are lower than the industry average while ensuring shielding performance, providing high cost-performance solutions.

Quality Advantage

We implement a three-level quality control system: raw material inspection, in-process inspection, and final product inspection. Each cabinet comes with a factory test report, with actual shielding effectiveness measured. Structural load-bearing and electrical safety indicators meet national standards, ensuring long-term stable performance.

Customization and OEM Services

Customization Scope

  • Size Customization: Height, width, and depth can be adjusted to fit special data center spaces and equipment sizes.
  • Performance Customization: Shielding grade can be customized to B, C, or higher, meeting different confidentiality levels.
  • Function Customization: Can integrate constant temperature cooling, UPS power, environment monitoring, fire protection, explosion-proof, and other modules.
  • Interface Customization: Configure power, network, fiber, USB, video, and other shielded interfaces with flexible quantity and type.
  • Internal Configuration Customization: Adjust shelves, rails, PDUs, cable management, KVM switches, etc., as needed.
  • Appearance Customization: Custom colors, logos, and lock types (combination, fingerprint, mechanical).

Customization Process

  1. Requirement Communication: Customer provides usage scenario, equipment parameters, size, and performance requirements.
  2. Solution Design: Technical team provides customization plan and drawings, confirming configuration, parameters, and pricing.
  3. Contract Signing: After confirmation, a contract is signed and deposit paid.
  4. Manufacturing: Production follows customized drawings with full quality control and regular progress updates.
  5. Factory Testing: Completed products undergo shielding effectiveness, structure, electrical full inspection, with test reports issued.
  6. Delivery and Acceptance: Shipping arranged, customer acceptance after receipt, with after-sales technical support.

Customization Advantages

  • Exclusive Solutions: One-on-one technical support, tailored plans to solve special scenario pain points.
  • Fast Response: Customization plans provided within 24 hours; small batch customization delivered in 7-15 days.
  • Performance Assurance: Custom products undergo the same testing standards as standard products, with certified shielding effectiveness and structural performance.
  • Full Service: Dedicated personnel follow from requirement communication, solution design, installation and commissioning, to after-sales maintenance.

OEM and Confidentiality

  • OEM Processing: Support customer-provided drawings or samples for OEM production, custom appearance, logos, and packaging. Neutral packaging available for brand and integrator needs.
  • Confidential Production Mechanism: All confidential customization projects sign confidentiality agreements. Production workshops are under closed management, project drawings and data strictly secured, with full traceability to prevent information leakage.
  • Cooperation Modes: ODM solution customization, OEM label production, semi-finished processing, etc., with sufficient capacity and stable delivery.
  • Qualification Sharing: Shared test reports and system certifications for OEM products, supporting customer bidding and acceptance.

Application Scenarios

  • Classified Data Centers: For government, military, and defense units, housing confidential servers and storage to prevent electromagnetic information leakage.
  • Secure Meeting Rooms: Deploying confidential conference hosts and recording shielding devices to ensure meeting information security.
  • Financial Data Centers: Protecting core trading equipment in banks and securities from electromagnetic interference and information theft.
  • Research Institutes: Electromagnetic protection for high-precision test instruments and confidential R&D equipment, avoiding external interference affecting test accuracy.
  • Command Centers: Protecting core operational and emergency command equipment, ensuring secure and stable command systems.
  • Industrial Control Scenarios: Protection for power plants and rail transit control systems after suffering strong electromagnetic interference in industrial environments.

Success Cases

Representative Clients

  • Government agencies: Multiple municipal data bureaus and confidentiality departments for confidential data center projects.
  • Military units: Supporting projects for multiple military research institutes.
  • Financial institutions: Core data center shielded cabinet projects for provincial branches of state-owned banks.
  • Central state-owned enterprises: Shielding protection for power and energy company industrial control systems.
  • Education and research: Electromagnetic protection projects for key laboratories at 985 universities.

Case Highlights

  • Military Confidential Data Center: Delivered 68 units of 42U C-grade shielded cabinets, all passed on-site shielding effectiveness tests and successfully passed the national confidentiality bureau’s second-level confidentiality qualification acceptance.
  • Government Data Bureau Level 3 Protection: Customized 22 units of 37U constant temperature shielded cabinets with integrated environment monitoring, achieving remote monitoring of temperature, humidity, access control, and smoke, meeting Level 3 requirements of Equal Protection 2.0.
  • University Research Laboratory: Customized 12 units of special-size shielded cabinets for imported high-precision test instruments, effectively shielding external electromagnetic interference, and improving test data stability by over 90%.

Maintenance and Troubleshooting

Troubleshooting

Fault Symptom Possible Cause Solution
————— —————- ———-
Shielding effectiveness degradation Shielded door not fully closed, poor spring contact Check and secure the door, clean dust and oxidation from springs, ensure good contact
Ventilation waveguide blocked or damaged Clean dust, replace if damaged with same specification
Cables not routed through filters All cables must pass through corresponding filters, no unauthorized holes
Door opening/closing difficulty Lock mechanism jammed, hinge rusted Lubricate lock and hinges, adjust door position
Poor internal heat dissipation Vents blocked, fan failure Clean vent waveguides, check fan power and operation, replace if faulty
Surface peeling and rust High humidity, surface scratches Light rust can be sanded and repainted, severe cases contact manufacturer; keep environment dry
Filter failure Lightning strike, overvoltage damage Replace with same specification filter, do not exceed rated load

Note: Repairs involving shielding structure modification must be performed by professional technicians. Unauthorized disassembly or welding of the cabinet is strictly prohibited to avoid irreversible shielding performance degradation.

Maintenance

  • Daily Cleaning: Regularly wipe cabinet surface with a dry soft cloth, avoid corrosive cleaners, keep shielding springs clean and free of dust and oil.
  • Monthly Inspection: Check door locking smoothness, spring contact, grounding terminal connection, and ground resistance.
  • Quarterly Maintenance: Clean ventilation waveguide dust, check fan operation, test internal temperature and humidity.
  • Annual Inspection: Have a professional agency perform shielding effectiveness test annually, calibrate seals and filters, and replace aged parts.
  • Long-term Storage: Store in a dry, ventilated environment, avoid heavy pressure and collision, power on periodically to prevent moisture.

Note: Unauthorized drilling or welding on the cabinet is prohibited to avoid damaging shielding seals; all cables must be routed through dedicated shielded interfaces.

Factory Strength and After-Sales Service

Factory Strength

Guangzhou Lain has a modern shielding equipment production base, equipped with CNC laser cutting machines, CNC bending machines, automated welding production lines, electrostatic spraying workshops, and shielding effectiveness testing laboratories. Annual production capacity exceeds 5,000 units of shielded cabinets and supporting equipment. The team has over 10 years of experience in electromagnetic shielding, with core engineers possessing extensive design experience in shielding rooms and cabinets, providing full-chain services from solution design, manufacturing, to on-site installation and commissioning.

After-Sales Service

  • Warranty: Warranty coverage is confirmed on the quotation.
  • Response Time: Support hours and on-site response are confirmed on the quotation.
  • Technical Support: Free installation guidance, usage training, and technical consultation; can assist with project acceptance testing.
  • Spare Parts Supply: Long-term supply of original parts, with common spare parts in stock to ensure timely replacement.
  • Upgrade Service: Provide old cabinet upgrade and renovation services, enhancing shielding levels, adding functional modules, and extending equipment lifespan.

Procurement Service Guarantee

  • Supply Guarantee: Self-owned factory with ample capacity, regular models in stock, and clear production priority for custom orders, strictly meeting contract delivery dates to ensure project progress.
  • Quality Guarantee: Full-process quality control, raw material inspection, spot checks at each production step, 100% final inspection. Each product includes a factory test report, supports third-party testing, and allows return/exchange if shielding effectiveness is not up to standard.
  • Logistics Guarantee: Cooperation with professional logistics lines, products are wood-framed and reinforced to avoid transport damage. Delivery to door and on-site unloading options are available, covering most domestic regions with full tracking.
  • After-Sales Guarantee: After-sales support and spare-parts supply are confirmed on the quotation.
  • Invoice Guarantee: We can issue 13% VAT special invoices and ordinary VAT invoices, either with the goods or separately, meeting customer financial and accounting requirements.

FAQ

Q1: What is the difference between a shielded cabinet and a regular cabinet?

A regular cabinet only provides equipment mounting and physical protection, with no electromagnetic shielding capability. A shielded cabinet uses a sealed metal enclosure and shielding components to isolate electromagnetic signals, preventing internal information leakage and resisting external interference, suitable for confidential and high-interference environments.

Q2: How to choose between B-grade and C-grade shielded cabinets?

B-grade shielding effectiveness is ≥60dB, suitable for general confidential and ordinary confidential units, with lower cost. C-grade shielding effectiveness is ≥80~100dB, suitable for high-level confidential, military, and core confidential departments. Choose based on project confidentiality level and acceptance requirements.

Q3: Can shielded cabinets be placed directly in a regular data center?

Yes. Shielded cabinets are independent shielding units that do not require data center modification. They can be placed on the floor and used immediately, offering a cost-effective alternative to large shielding rooms.

Q4: How are cables (network, power) connected into a shielded cabinet?

All incoming and outgoing cables must be connected through dedicated power filters and signal filters. Direct drilling and wiring are strictly prohibited as it would compromise shielding effectiveness. Configure corresponding shielded interfaces and filters according to device interface types.

Q5: Does a shielded cabinet need grounding?

Yes. Reliable grounding is essential, with ground resistance ≤4Ω. Proper grounding ensures shielding effectiveness and static discharge. The product is equipped with dedicated grounding terminals that must be connected to the data center grounding system.

Conclusion

Shielded cabinets are the core physical barrier for electromagnetic security in classified information systems. Choosing stable and reliable shielding equipment is the foundation for information security. With over 10 years of experience in electromagnetic shielding equipment development and manufacturing, KITOZER provides professional electromagnetic shielding solutions with high-quality products, comprehensive service, and flexible customization capabilities. For more details on shielded cabinet prices, customization plans, and stock availability, please contact us for detailed information and quotations.