Manufacturer: Guangzhou Lain Intelligent System Development Co., Ltd.
Document Version: V3.0
Release Date: July 2026
Applicable Models: LA-YSG-12, LA-YSG-24, LA-YSG-36, LA-YSG-60, LA-YSG-100, LA-YSG-150 Series Intelligent Control Key Cabinets
Table of Contents
TogglePreface

In modern intelligent control and management systems, keys serve as the core physical carrier of access permissions. Their management efficiency and security level directly impact the operational order and risk prevention capabilities of enterprises and public institutions. Traditional key management models rely on manual registration and dedicated personnel supervision, which commonly suffer from unclear responsibilities, difficult traceability, inefficient access, and hard-to-trace losses. In high-security scenarios such as classified facilities, high-risk industrial sites, and public service institutions, the security vulnerabilities and management cost issues of traditional models are particularly prominent.
Guangzhou Lain Intelligent System Development Co., Ltd. has been deeply engaged in the field of intelligent control equipment for many years. Leveraging core technologies including RFID radio-frequency identification, biometric recognition, IoT cloud platforms, and embedded industrial control, we have independently developed a full series of intelligent key cabinet products. We have established a complete closed-loop control system covering “identity verification – permission allocation – access recording – real-time monitoring – anomaly alerting – data traceability,” achieving digital, intelligent, and visualized upgrades in key management.
This manual is the official installation, wiring, and commissioning guidance document for the full range of Guangzhou Lain intelligent key cabinets. It covers the complete technical documentation for the entire product lifecycle, including product understanding, deployment implementation, commissioning and operation, maintenance, fault troubleshooting, and acceptance and delivery. It is designed to provide comprehensive, rigorous, and actionable technical guidance for project implementation personnel, operations and maintenance managers, and end users. All relevant personnel must read this manual carefully before operation and strictly follow the standardized procedures to ensure safe and stable equipment operation.
The content of this manual will be continuously updated in accordance with product technology iterations. The final interpretation rights belong to Guangzhou Lain Intelligent System Development Co., Ltd.
Chapter 1 Product Introduction

1.1 Product Definition and Overview
The intelligent key cabinet belongs to the category of intelligent control equipment. It is an intelligent key storage and management device that integrates identity recognition, permission control, presence detection, data recording, and anomaly alarm functions into one unit. Its core logic is to digitize physical keys through IoT technology, assigning each key a unique electronic identity identifier, while deeply binding personnel identities with key permissions. This enables automatic recording, real-time supervision, and responsibility traceability throughout the entire key access process, replacing traditional manual registration management models and comprehensively improving the security, efficiency, and compliance of key management.
Guangzhou Lain intelligent key cabinets use high-strength cold-rolled steel plates as the cabinet base material, equipped with an embedded industrial control host, RFID read/write array, multimodal identity recognition terminal, independent electronic lock control system, and audible/visual alarm module. They are supplemented by local management software and a cloud management platform, supporting both standalone operation and multi-unit networked centralized management. The cabinets can be widely adapted to key management needs of different scales and security levels, serving as core foundational equipment in modern smart security, smart logistics, and smart asset management systems.
1.2 Product Development Background and Industry Trends
1.2.1 Industry Pain Points of Traditional Key Management Models
Before the widespread adoption of intelligent technology, the vast majority of domestic enterprises and institutions used the traditional model of “key board + registration book + dedicated management personnel.” This model has exposed multiple systemic deficiencies over long-term practice:
- Prominent security control vulnerabilities: Key access relies solely on manual verification, creating risks of proxy collection, fraudulent collection, and unauthorized duplication. If keys to sensitive areas are obtained by unauthorized personnel, it may lead to serious consequences such as property loss, information leakage, and safety incidents. After keys are lost, responsibility cannot be quickly identified, and post-event traceability lacks effective evidence.
- Severely low management efficiency: Access and return require manual signature registration, and queues can form during peak periods. With large numbers of keys, locating a specific key is time-consuming and labor-intensive, delaying response in emergency situations. Shift handovers require one-by-one key verification, making the handover process cumbersome and error-prone.
- Persistently high management costs: Dedicated key management positions must be staffed, requiring continuous labor cost investment. Paper registration records accumulate over time, making archiving, retrieval, and auditing difficult. Replacement and rekeying costs after key loss are uncontrollable.
- Difficult compliance auditing: For regulated industries such as classified units, industrial plants, and financial institutions, key management records must meet audit requirements. Manual registration is prone to omissions, errors, retroactive entries, and tampering, making it impossible to form tamper-evident compliance ledgers or pass special audits.
1.2.2 Technology Evolution and Product Development History
The technological development of intelligent key cabinets has roughly gone through three stages:
- Stage 1 – Electronic Password Cabinet Stage: Electronic locks replaced traditional mechanical locks, improving the security of cabinet opening. However, the access and storage of keys themselves remained uncontrolled. This stage only solved “cabinet security,” not “key management.”
- Stage 2 – IC Card Control Stage: Card swiping was used to open cabinet doors, achieving initial personnel identity recognition. Some products added contact-based presence detection to monitor whether keys were in place. However, recognition accuracy was low and susceptible to interference, and permission management granularity was coarse, unable to achieve single-key-level permission control.
- Stage 3 – RFID Intelligent Control Stage: This is also the current mainstream technology stage, with RFID radio-frequency identification as the core, combined with biometric recognition, cloud platforms, and big data analytics. It achieves unique identification of individual keys, fine-grained permission allocation, full-process operation traceability, multi-device networked management, and remote approval control, truly forming a complete intelligent control closed loop.
1.2.3 Industry Development Trends
With the continued advancement of smart office, smart security, and digital government initiatives in China, the intelligent key cabinet industry is showing three major development trends:
- Multimodal fusion of recognition technologies: Single card-swipe or password verification can no longer meet high-security scenario requirements. Biometric technologies such as face recognition, fingerprint recognition, finger-vein recognition, and iris recognition are deeply integrated with RFID technology, supporting multi-factor combined verification with continuously rising security levels.
- Open system ecosystems: The evolution is moving from standalone devices to system-level solutions, supporting integration with OA office systems, access control systems, visitor systems, vehicle management systems, and security surveillance systems. This integrates into the organization’s overall intelligent framework, enabling data interoperability and linked control.
- Refined management scenarios: Development is moving from general-purpose key management to vertical scenario deepening, giving rise to specialized products such as military firearms key cabinets, power inspection key cabinets, hospital narcotic and psychotropic drug key cabinets, and property engineering key cabinets. Customized functions are developed according to management rules of different industries, with continuously enhanced adaptability.
1.3 Product Core Value
Guangzhou Lain intelligent key cabinets address traditional management pain points and deliver four core values to users:
Security Value – Full-Dimension Risk Prevention and Control
Through four layers of protection—identity verification, permission binding, real-time monitoring, and anomaly alerting—a complete security chain is formed from personnel access, key storage and retrieval, process monitoring, to post-event traceability. This eliminates unauthorized access, significantly reduces key management security risks, and safeguards the physical security of classified areas, high-hazard equipment, and important assets.
Efficiency Value – Full-Process Efficiency Improvement
Self-service access operations require no manual supervision, with second-level door opening after verification. Indicator lights guide users to quickly locate keys, with the entire operation taking no more than 30 seconds. The system automatically generates statistical reports, eliminating manual registration and ledger management work, improving key management efficiency by more than 80%.
Cost Value – Full-Cycle Cost Reduction
Replaces dedicated key management positions, reducing labor costs. Digital records replace paper registration, reducing consumable and archiving costs. Precise responsibility traceability reduces key loss rates, lowering replacement and rekeying costs. The equipment is stable and durable, with low full-lifecycle operations and maintenance costs.
Compliance Value – Full-Data Audit Support
All operation logs are tamper-evident and traceable, supporting multi-dimensional query and export by time, personnel, and key. This forms complete compliance ledgers, meeting the audit requirements of classified units and regulated industries, and providing reliable data evidence for safety inspections and responsibility determination.
1.4 Product Model System Description
Guangzhou Lain intelligent key cabinets adopt a modular design philosophy, forming a complete product model matrix that meets the needs of different capacities, installation methods, and security levels:
By Key Capacity
| Series | Models | Applicable Scenarios |
|---|---|---|
| Small Series | LA-YSG-12 (12 positions), LA-YSG-24 (24 positions) | Offices, small duty rooms, stations, and other scenarios with fewer keys. Supports wall-mounted installation to save space. |
| Medium Series | LA-YSG-36 (36 positions), LA-YSG-60 (60 positions) | Medium-sized enterprises, property project departments, grassroots units, etc. Supports both wall-mounted and floor-standing installation. |
| Large Series | LA-YSG-100 (100 positions), LA-YSG-150 (150 positions) | Large enterprises, government agencies, vehicle fleets, industrial plants, and other scenarios with large key volumes. Floor-standing structure, supporting multi-cabinet cascade expansion. |
By Security Level
| Level | Features | Applicable Scenarios |
|---|---|---|
| Standard | Card swipe + password verification | Ordinary office, property management, and other routine scenarios. |
| Enhanced | Face recognition + fingerprint recognition + card swipe multi-factor verification | Government agencies, enterprises and institutions, and other medium security requirement scenarios. |
| High Security | Binocular liveness face recognition + finger-vein recognition + dual-person dual-lock verification + anti-pry alarm | Public security, judicial, military/police, energy and chemical industries, and other high-security-level scenarios. |
By Installation Method
| Type | Description |
|---|---|
| Wall-Mounted | Slim cabinet body, mounted against walls, saving floor space. Suitable for 12–60 position capacity models. |
| Floor-Standing | Vertical cabinet body with adjustable feet at the bottom for stable placement. Suitable for 36–150 position capacity models. |
| Combined | Main cabinet + auxiliary cabinet cascade combination, allowing unlimited expansion of key capacity. Suitable for ultra-large key management scenarios. |
Chapter 2 Product Composition

Guangzhou Lain intelligent key cabinets consist of two major parts: the hardware system and the software system. The hardware system includes cabinet structure, core control, identity recognition, lock control and detection, power supply and security subsystems. The software system includes three tiers: embedded terminal software, local management software, and cloud management platform. Hardware and software work together to achieve complete control functions.
2.1 Cabinet Hardware Structure System
The cabinet serves as the physical carrier and protection foundation of the intelligent key cabinet. It adopts an integrated sheet metal structure design with high strength, anti-pry, anti-rust, and durability characteristics. The specific composition is as follows:
Cabinet Main Frame
Manufactured from 1.2–1.5mm high-quality cold-rolled steel plates through CNC punching, bending, and welding. The overall structure is stable, impact-resistant, and pry-resistant. The cabinet surface undergoes acid washing, phosphating, and electrostatic powder coating, providing uniform coating with corrosion resistance, wear resistance, and fade resistance. The standard colors are matte gray and police blue, with custom colors available upon user request.
Cabinet Outer Door Panel
The door panel is connected to the cabinet body using reinforced hinges, opening smoothly and closing tightly. The door panel features an observation window made of 5mm toughened glass with good light transmission and impact resistance, allowing direct viewing of internal key presence status for quick inventory without opening the door. High-security models feature all-steel door panels without observation windows, further enhancing pry resistance.
Internal Key Slot Units
The cabinet interior is arranged in layers with independent key slots, each corresponding to one key. Each slot contains an RFID antenna, presence detection sensor, LED status indicator, and independent electronic lock bolt. Slots are injection-molded from flame-retardant ABS engineering plastic with good insulation properties and long service life. Slot numbers are laser-engraved for clarity and durability.
Bottom Adjustment Base (Floor-Standing)
Floor-standing cabinets are equipped with 4 adjustable metal leveling feet at the bottom, with an adjustment range of 0–20mm, accommodating uneven floors to ensure the cabinet is level and preventing operational issues with cabinet doors and locks caused by tilting. The feet are fitted with anti-slip rubber pads to enhance placement stability and protect the floor.
Wall-Mounting Back Plate (Wall-Mounted)
Wall-mounted cabinets feature a reinforced mounting back plate on the rear, with pre-drilled standard mounting holes. The back plate is integrally welded with the cabinet frame, providing strong load-bearing capacity to ensure secure and reliable wall mounting. Single-cabinet wall-mounted load capacity reaches 80kg or more.
Cable Routing Channels and Wiring Compartment
A dedicated wiring compartment and hidden cable routing channels are provided at the rear of the cabinet. All power cables, network cables, and peripheral connection cables are routed through internal channels, providing neat and tidy wiring while avoiding safety hazards and sabotage risks from exposed cables.
2.2 Core Control Module
The core control module is the “brain” of the intelligent key cabinet, responsible for overall machine computation, logic control, data processing, and command issuance. It is the core component ensuring stable equipment operation.
Embedded Industrial Main Board
Uses industrial-grade RK3568/RK3288 main control chips with quad-core Cortex-A architecture, 1.8GHz main frequency, providing robust performance and stable operation. Standard configuration includes 2GB DDR4 RAM + 16GB EMMC solid-state storage, with high-configuration versions supporting 4GB+32GB configurations, smoothly running embedded systems and control software to meet multi-task parallel processing requirements. The main board features a wide-temperature design, supporting operating temperatures from -10°C to 70°C, adapting to various complex environments.
Main Control Unit Expansion Interfaces
The main board integrates a rich set of peripheral interfaces, including RJ45 Ethernet port, USB2.0/3.0 ports, RS485 serial ports, GPIO interfaces, audio interfaces, and HDMI interfaces, flexibly connecting various peripheral modules to meet functional expansion and system integration requirements.
Lock Control Driver Board
An independent lock control driver board handles the signal driving and status acquisition for all electronic locks, indicator lights, and sensors. It uses a distributed architecture, with a single driver board managing up to 30 lock positions and supporting multi-board cascade expansion. The driver board features overcurrent, overvoltage, and short-circuit protection to prevent single-channel faults from affecting overall operation, ensuring the safety and stability of the lock control system.
RFID Read/Write Control Board
The RFID control board handles the transmission, reception, and data parsing of radio-frequency signals. It supports 13.56MHz high-frequency RFID protocols, compatible with ISO14443A/B standards, and can simultaneously read key tag information from multiple slots. Recognition response time is <0.2 seconds, with recognition accuracy ≥99.99%. The control board includes signal gain adjustment functionality, allowing read/write power to be adjusted based on site conditions to avoid cross-reading and missed reads.
2.3 Identity Recognition Module
The identity recognition module handles personnel identity verification and serves as the first gateway for permission control. Guangzhou Lain intelligent key cabinets support multiple recognition methods, configurable according to model and requirements:
Face Recognition Module
Uses a binocular wide-dynamic-range camera with liveness detection algorithms, effectively defending against photo, video, and mask spoofing attacks. Recognition accuracy is ≥99.9%, with recognition speed ≤0.5 seconds. Supports low-light and backlight environment recognition, adapting to different lighting conditions. Standard face library capacity is 10,000 faces, expandable to 50,000 faces, meeting the needs of large organizations.
Fingerprint Recognition Module
Uses a semiconductor capacitive fingerprint sensor with 508DPI resolution, supporting dry/wet fingers and shallow fingerprint recognition. Features fingerprint liveness detection to prevent fake fingerprints. Standard fingerprint capacity is 5,000 templates, with recognition speed ≤0.3 seconds, false rejection rate ≤0.01%, and false acceptance rate ≤0.0001%, providing stable and reliable performance.
IC Card Recognition Module
Supports ISO14443A standard IC cards (M1 cards), CPU cards, and ID card serial number reading. Card reading distance is 0–5cm, with response speed ≤0.2 seconds. Built-in lightning and surge protection circuits adapt to various industrial environments. Compatible with users’ existing access control cards and employee badges, enabling one-card management.
Password Input Module
Integrated into the touch display, supporting virtual password keypad input. Password length is adjustable from 6–16 digits, supporting hierarchical management of administrator passwords and user passwords. Features anti-peeping password scrambling functionality to enhance password input security.
High-Security Model Exclusive Recognition Configuration
High-security models can be optionally equipped with finger-vein recognition modules and iris recognition modules, offering stronger biometric uniqueness and higher security levels, suitable for classified, military, and other extremely high-security scenarios.
2.4 Key Detection and Lock Control Module
This module serves as the execution terminal for key control, directly implementing key locking, detection, and status indication functions.
Independent Electronic Locks
Each key slot is equipped with an independent miniature electronic lock using electromagnetic attraction principles, featuring low power consumption and long service life, with mechanical life ≥100,000 cycles. The lock bolt is made of stainless steel for strength and wear resistance. In the locked state, keys cannot be forcibly extracted, ensuring physical key security. The electronic locks maintain the locked state upon power failure, preventing key loss of control after power outages.
RFID Electronic Key Fobs
Each key is paired with a dedicated RFID electronic key fob containing a passive RFID chip with a globally unique ID number, requiring no power supply and offering long service life. The key fob is made of high-strength ABS material, waterproof and drop-resistant, physically bound to the key via stainless steel wire that cannot be privately removed. Once removed, the tag becomes invalid, preventing key substitution.
Presence Detection Sensors
Each slot is equipped with a dual presence detection mechanism: first, RFID tag recognition detection, which determines key presence by reading tag signals; second, physical photoelectric sensor detection, which determines key fob return status through infrared light sensing. The dual detection mechanisms cross-validate each other, avoiding misjudgment caused by single sensor failure, with 100% detection accuracy.
Slot Status Indicator Lights
Each key slot is equipped with an independent LED indicator light above it, providing slot information through different colors and states: steady green indicates the key is present and normal; flashing red indicates the key has been authorized for collection; steady red indicates the key has been borrowed; flashing yellow indicates a fault or anomaly. The intuitive and clear light guidance significantly improves user efficiency in returning and retrieving keys.
2.5 Power Supply Module
A stable and reliable power supply system is the foundation for continuous equipment operation. Guangzhou Lain intelligent key cabinets adopt a multi-level power supply design to ensure power supply safety.
Power Adapter
Standard configuration includes an industrial-grade switching power adapter with AC 100-240V wide-voltage input, adapting to global mains voltage standards. Output is DC 12V/5A with sufficient power to meet the power requirements of all cabinet modules. The power adapter features overvoltage, overcurrent, overtemperature, and short-circuit protection, and is 3C certified for safety and reliability.
Internal Power Distribution Board
A dedicated power distribution board is installed inside the cabinet, distributing input power to different modules including the main control, recognition, lock control, and peripheral devices. Each channel has independent voltage regulation and independent protection, so a single-channel fault does not affect other modules. Power filtering circuits are also included to suppress grid interference and enhance power supply stability.
Backup UPS Power Supply (Optional)
An optional built-in lithium battery UPS module is available, with standard 12V/10Ah capacity. Under normal mains power, it automatically float-charges; upon power failure, it automatically switches to battery power, providing more than 8 hours of continuous standby. It supports automatic safe shutdown at low battery levels to protect both the battery and system safety.
Emergency Power Supply Interface
A hidden Type-C emergency power supply interface is located at the bottom of the cabinet. When the built-in power supply is completely depleted, an external power bank can be connected for temporary power supply, enabling emergency door opening for key retrieval and preventing emergency situations where keys cannot be accessed due to power failure.
2.6 Alarm and Security Module
The security alarm module is an important safeguard for equipment security, promptly detecting and providing early warning for various abnormal situations.
Audible/Visual Alarm
A high-decibel buzzer and high-brightness LED warning light are installed at the top of the cabinet. When an alarm is triggered, it emits sound above 85dB with flashing red light, serving as a deterrent and notification. The alarm volume is adjustable to avoid noise interference in quiet environments.
Anti-Pry Vibration Sensor
A high-precision vibration sensor is installed inside the cabinet with multi-level adjustable sensitivity. When the cabinet is subjected to prying, impact, or forced movement, the sensor triggers an alarm. The system automatically records the alarm time and pushes alarm information to the administrator.
Door Magnetic Detection Sensor
An independent door magnetic sensor is installed on the cabinet door, monitoring the door open/close status in real time. Unauthorized door opening, incomplete door closure, and other situations will trigger alarm notifications, ensuring the door status is fully controllable throughout.
Smoke and Temperature Detectors (Optional)
Optional built-in smoke detection and temperature sensing modules monitor the environmental conditions inside the cabinet in real time. Alarms are triggered when smoke or abnormal temperatures are detected, preventing fire hazards. Suitable for high-security scenarios storing important keys.
2.7 Software Management System
The software system serves as the control core of the intelligent key cabinet, divided into three tiers—terminal layer, local layer, and cloud layer—implementing management functions at different dimensions.
Embedded Terminal Software
Runs on the cabinet touch screen, using an Android/Linux embedded system with a simple, intuitive interface and easy operation. Responsible for local identity verification, access operations, status display, and local alarms. Supports offline standalone operation, remaining fully functional without network connectivity. Operational data is cached locally and automatically synchronized when the network is restored.
Local Management Software
Installed on Windows computers, it can connect to single or multiple intelligent key cabinets via LAN, implementing personnel management, key management, permission assignment, record queries, report exports, and system settings. Supports multi-level administrator permissions, where different administrators can be assigned different operational permissions to meet hierarchical management requirements.
Cloud Management Platform
Based on a B/S architecture, administrators can log in and access the platform via browser without geographical restrictions. Supports centralized management of multiple sites and devices, with real-time viewing of all device operating status and key presence conditions. Features include remote approval, alarm push notifications, and big data statistical analysis, suitable for group-based and distributed deployment users. The platform supports private deployment to ensure user data security.
2.8 Accessory System
In addition to the main equipment, the product is accompanied by a complete set of accessories to support the full process of installation, use, and maintenance:
- Installation accessories: Expansion bolts, mounting screws, spirit level, cable routing channels, cable clips, insulating tape, etc.
- Key binding accessories: RFID key fobs, stainless steel wire, wire cutters, crimping pliers, etc.
- Emergency accessories: Mechanical emergency keys, emergency power cables, spare fuses, etc.
- Documentation: This manual, certificate of conformity, warranty card, software installation package, factory test report, etc.
Chapter 3 Product List
3.1 Standard Configuration List
Taking the LA-YSG-60 intelligent key cabinet as an example, the standard factory configuration list is as follows:
| No. | Component Name | Specification/Model | Qty | Unit | Remarks |
|---|---|---|---|---|---|
| 1 | Intelligent key cabinet main unit | LA-YSG-60 | 1 | Unit | Includes cabinet body, main control, lock control, detection modules |
| 2 | Touch display screen | 10.1-inch capacitive touch screen | 1 | Piece | 1280×800 resolution |
| 3 | Face recognition module | Binocular liveness recognition module | 1 | Set | Standard on Enhanced and above models |
| 4 | Fingerprint recognition module | Semiconductor fingerprint sensor | 1 | Piece | Standard on Enhanced and above models |
| 5 | IC card reader module | 13.56MHz high-frequency card reader | 1 | Piece | Standard on all models |
| 6 | Power adapter | DC12V/5A industrial grade | 1 | Piece | 3C certified |
| 7 | RFID electronic key fobs | ISO14443A high-frequency | 60 | Pieces | Corresponds to slot quantity |
| 8 | Mechanical emergency keys | Custom brass | 2 | Pieces | Emergency cabinet door unlocking |
| 9 | Expansion bolt installation kit | M8×80mm | 4 | Sets | For wall-mounted installation |
| 10 | Power cable | 3×1.0mm², 1.5m | 1 | Piece | National standard copper core |
| 11 | Network cable | Cat5e, 1m | 1 | Piece | For network connection |
| 12 | Certificate of conformity | / | 1 | Sheet | Factory inspection certified |
| 13 | Warranty card | / | 1 | Sheet | After-sales service certificate |
| 14 | Product manual | / | 1 | Copy | Paper version |
Note: The number of key fobs, slot quantity, and cabinet dimensions are adjusted accordingly for different capacity models. The remaining standard configuration remains essentially consistent.
3.2 Optional Accessory List
Users can select the following accessories as needed to enhance product functionality and adaptability:
| No. | Accessory Name | Function Description | Compatible Models |
|---|---|---|---|
| 1 | Built-in UPS backup power supply | 12V/10Ah lithium battery, 8-hour backup on power failure | All models |
| 2 | Auxiliary cabinet expansion unit | No main control, cascaded through main cabinet, expands key capacity | Main cabinets of 36 positions and above |
| 3 | Finger-vein recognition module | Higher security level biometric recognition | High-security models |
| 4 | 4G communication module | Supports 4G full-network connectivity, no cabling required | All models |
| 5 | Wi-Fi module | Supports wireless network connectivity | All models |
| 6 | Thermal printer | On-site printing of access vouchers | Floor-standing models |
| 7 | HD camera | Captures images during operations for evidence, can be linked with recording | All models |
| 8 | Smoke and temperature detector | In-cabinet environment monitoring and fire early warning | High-security models |
| 9 | Floor-standing mobile base | With casters and brakes, facilitates cabinet mobility | Floor-standing models |
| 10 | Access control integration module | Enables data interoperability with existing access control systems | All models |
3.3 Packaging Material List
The product uses standardized industrial packaging to ensure safe and damage-free transport. Packaging materials include:
- Outer carton: High-strength five-layer corrugated cardboard box with waterproof film coating, printed with product model, brand, fragile marking, and direction markings.
- Internal cushioning padding: High-density EPE pearl cotton custom-molded to wrap all edges and protruding components of the cabinet, providing cushioning and shock absorption to prevent transport damage.
- Accessory packaging boxes: Independent small cartons for packaging the power supply, key fobs, screws, and other loose accessories to prevent loss and mixing.
- Waterproof and dustproof bag: The complete unit is wrapped in a thickened PE plastic bag for moisture and dust protection, suitable for humid environments and long-distance transport.
- Strapping bands: Cross strapping bands reinforce the outer carton to prevent box separation during transport.
- Wooden packaging box (optional): For long-distance logistics, export transport, and other scenarios, custom solid wood fumigated wooden crates can be selected for higher protection levels.
3.4 Documentation List
Each unit ships with complete technical documentation, provided in paper form with the shipment, along with electronic versions on CD or via cloud download:
1. *Intelligent Key Cabinet Installation, Wiring, and Commissioning Manual* (this document)
2. *Intelligent Key Cabinet Management Software Operation Manual*
3. *Product Factory Inspection Report*
4. *Product Certificate of Conformity*
5. *Product Warranty Card*
6. *Software Installation Package and Drivers*
7. *Product 3C Certification Certificate Copy*
8. *ISO9001 Quality System Certification Copy*
Chapter 4 Product Working Principles
4.1 RFID Radio-Frequency Identification Principle
RFID radio-frequency identification is the core foundational technology of the intelligent key cabinet. Its essence is to achieve contactless information transfer and identity recognition through spatial coupling of radio-frequency signals.
4.1.1 System Composition
The RFID recognition system consists of three parts:
| Component | Description |
|---|---|
| Electronic tag (RFID key fob) | Contains an RF chip and antenna, storing a unique ID code and key information. It is a passive tag requiring no internal battery, operating by harvesting energy from the RF field emitted by the reader/writer. Each tag has a globally unique ID that cannot be replicated, ensuring the identity uniqueness of each key. |
| Reader/writer and antenna array | The reader/writer generates RF signals and receives information returned by tags. Each slot inside the cabinet corresponds to a set of miniature antennas forming an antenna array, communicating with the tags in their respective slots to avoid crosstalk. The reader/writer transmits the read tag IDs to the main control unit for processing. |
| Data processing unit | The main control motherboard, responsible for parsing, comparing, and storing the tag information read, determining key identity and presence status, and executing corresponding control logic. |
4.1.2 Working Process
1. When a key fob is placed into a slot, it enters the RF coverage range of the corresponding antenna. The tag antenna receives the RF electromagnetic waves emitted by the reader/writer, generating induced current through electromagnetic induction to provide working energy for the tag chip.
2. Once the tag chip is activated, it transmits its stored ID information through the built-in antenna.
3. The slot antenna receives the RF signal returned by the tag and transmits it to the reader/writer for demodulation and decoding, extracting the tag ID data.
4. The reader/writer sends the tag ID to the main control unit, which compares it with the binding information in the system database, confirms the key identity and corresponding slot, and updates the key presence status.
5. When the key is removed, the tag leaves the RF field, the reader/writer can no longer detect the tag signal, and the main control unit determines the key is absent, recording the removal time and operator information.
4.1.3 Technical Advantages
Compared with traditional contact-type and photoelectric detection methods, RFID detection offers multiple advantages:
- Non-contact recognition, no mechanical wear, long service life;
- Fast recognition speed, millisecond-level response, strong real-time performance;
- Can store more information—not only determining presence status but also identifying key identity, preventing misplacement;
- Strong anti-interference capability, unaffected by dust, moisture, oil contamination, and other environmental factors;
- Tags are unique and non-replicable, providing higher security.
4.2 Identity Verification and Permission Control Principle
Permission control is the core logic of the intelligent key cabinet. Its essence is to establish a mapping relationship between “personnel – identity characteristics – key permissions,” ensuring that only authorized personnel can retrieve keys within their corresponding permissions.
4.2.1 Identity Verification Process
1. The user selects the “Retrieve Key” operation on the touch screen, and the system prompts for identity verification.
2. The user selects a verification method (face/fingerprint/card/password), and the corresponding recognition module captures the user’s identity characteristic information.
3. The recognition module compares the captured characteristics with the pre-stored characteristic templates in the system, calculating similarity.
4. If the similarity reaches the preset threshold, identity verification passes; otherwise, verification fails, and the system prompts for re-verification or denies the operation.
5. In high-security mode, multi-factor verification is supported, requiring two or more identity verifications to pass simultaneously before system access is granted, further enhancing security.
4.2.2 Permission Matching Logic
After identity verification passes, the system automatically executes permission matching:
1. The system retrieves the user’s key permission list based on the user ID, clarifying which key numbers can be borrowed, borrowing time windows, and maximum borrowing duration rules.
2. The system sends commands to the slot indicator lights of the corresponding authorized keys, with flashing lights guiding the user for retrieval.
3. When the user presses the corresponding slot button or directly removes the key, the system re-verifies whether the key is within the user’s permission scope. If authorized, the electronic lock unlocks and the key can be removed; if not authorized, the lock remains locked while a prompt tone is triggered.
4. The system supports a multi-level permission system: super administrators have all permissions and can manage all personnel and keys; department administrators can only manage personnel and keys within their department; regular users can only retrieve keys within their own permissions.
4.2.3 Approval Process Principle
For keys requiring approval, the system supports a multi-level approval mechanism:
1. The user submits a key borrowing application through the terminal or APP, filling in the purpose and duration of borrowing.
2. The system automatically pushes the application to the approver’s account, who can process the approval via computer or mobile device.
3. Upon approval, the system temporarily grants the user access permission to the corresponding key, with a validity time limit set.
4. If the approval is rejected, permission is not granted, and the rejection reason is fed back to the applicant.
5. In emergency scenarios, administrators can grant one-click remote authorization without going through the normal approval process, ensuring emergency response efficiency.
4.3 Key Presence Detection Principle
Guangzhou Lain intelligent key cabinets employ a dual presence detection mechanism of “RFID recognition + photoelectric detection” to ensure accurate and reliable status detection.
4.3.1 RFID Detection Mechanism
As described in Section 4.1, the slot antenna reads the tag signal in real time. A stable tag signal indicates presence; signal disappearance indicates absence. This mechanism can identify key identity and determine whether a key has been misplaced into another slot. If misplacement occurs, the system automatically triggers an alarm prompting the user to return the key to the correct position.
4.3.2 Photoelectric Detection Mechanism
Each slot contains a pair of infrared through-beam photoelectric sensors, with the emitter emitting an infrared beam and the receiver detecting it. When the key fob is correctly returned, it blocks the infrared beam, interrupting the receiver signal, and the system determines the key is present. After the key is removed, the beam is restored, and the system determines the key is absent.
4.3.3 Dual Verification Logic
The system simultaneously collects both detection signals and performs logical validation:
| RFID Detection | Photoelectric Detection | System Determination |
|---|---|---|
| Present | Present | Key confirmed present, status normal |
| Absent | Absent | Key confirmed absent, borrowing recorded |
| Tag detected | Beam not blocked | Key not correctly returned, prompt to reposition |
| Beam blocked | No corresponding tag read | Non-matching key placed in slot, misplacement alarm triggered |
Through dual verification, misjudgments caused by single sensor failure, foreign object obstruction, tag damage, and other factors are completely avoided, ensuring 100% accuracy of presence status.
4.4 Electronic Lock Drive and Control Principle
4.4.1 Electronic Lock Working Principle
The key slots use miniature DC electromagnetic locks, primarily consisting of an iron core, coil, spring, and lock bolt:
| State | Description |
|---|---|
| Locked state | Coil not energized, spring pushes the lock bolt outward, engaging the locking hole of the key fob, preventing key extraction. |
| Unlocked state | Coil energized, generating electromagnetic attraction that retracts the iron core, pulling the lock bolt back, allowing free key removal. |
| Power-off holding | Normally-closed design: upon power failure, the spring maintains the lock bolt in the extended position, keeping the lock in the locked state, ensuring key security during power outages and preventing control failure due to power loss. |
4.4.2 Lock Control Drive Logic
1. After receiving a legitimate unlock command, the main control unit sends an unlock signal to the lock control driver board, including the slot number and unlock duration.
2. The corresponding channel of the driver board outputs drive voltage, energizing the electronic lock coil, and the lock bolt retracts to complete unlocking.
3. The system default unlock duration is 5 seconds, after which the lock automatically re-engages, preventing safety hazards caused by forgotten locking.
4. Each channel of the driver board has a resettable fuse in series. When a lock short-circuits or current is excessive, the fuse automatically disconnects to protect the drive circuit, and automatically recovers after the fault is resolved.
4.5 Data Communication and Transmission Principle
The intelligent key cabinet supports multiple communication methods, enabling data exchange between the device, management terminals, and the cloud.
4.5.1 Wired Network Communication
Connects to LAN via RJ45 Ethernet port, transmitting data using TCP/IP protocol. Provides stable transmission, high speed, and high security, making it the preferred communication method for fixed deployment scenarios. The device supports both static IP and dynamic IP (DHCP) configuration modes, adapting to different network environments.
4.5.2 Wireless Network Communication
Optional Wi-Fi module or 4G module:
| Type | Description |
|---|---|
| Wi-Fi communication | Supports 2.4GHz frequency band, compatible with mainstream routers, suitable for scenarios where cabling is difficult but Wi-Fi coverage exists. |
| 4G communication | Supports full network compatibility for China Mobile, China Unicom, and China Telecom. Connects to the network by inserting a SIM card without relying on existing networks, suitable for remote sites and temporary deployments. |
4.5.3 Serial Communication
RS485 serial ports enable main-auxiliary cabinet cascade communication. Main and auxiliary cabinets are connected via a bus, with distance up to 1000 meters, supporting cascade connection of up to 255 auxiliary cabinets for expanded large-capacity key control. The serial ports can also interface with third-party systems such as access control and alarm systems.
4.5.4 Data Transmission Mechanism
- Local operational data is stored in real time in the terminal’s local storage, while automatically synchronizing to the local server and cloud platform;
- When the network is interrupted, data is cached locally and automatically resumes transmission from the breakpoint after network recovery, ensuring no data loss;
- All data transmission uses AES encryption algorithms to prevent data theft and tampering, ensuring data transmission security;
- Cloud platform data uses multi-copy storage with regular automatic backups, ensuring data security and reliability.
4.6 Overall System Workflow
4.6.1 Complete Key Retrieval Process
1. The user clicks “Retrieve Key” on the touch screen;
2. The system prompts for identity verification, and the user completes face/fingerprint/card/password verification;
3. After the system verifies the identity as valid, the user’s permission list is retrieved, and indicator lights on authorized key slots flash;
4. The user opens the cabinet door, locates the slot with the flashing indicator light, and removes the key;
5. The system detects key absence, recording the retrieval time, personnel, and key number;
6. The user closes the cabinet door, the system detects door closure, and the retrieval process is complete with automatic door locking.
4.6.2 Complete Key Return Process
1. The user clicks “Return Key” on the touch screen, optionally choosing identity verification or directly scanning the key fob for verification;
2. The system identifies the key identity, and the corresponding slot indicator light flashes to indicate the return position;
3. The user opens the cabinet door and inserts the key fob into the corresponding flashing slot, hearing a “click” sound indicating locked-in position;
4. The system dually detects the key is correctly returned, records the return time, and updates the key status to present;
5. The user closes the cabinet door, and the system locks the door, completing the return process.
4.6.3 Anomaly Alarm Process
1. Sensors detect an abnormal event (illegal prying, overdue return, door not closed, misplaced key, etc.);
2. The main control unit determines the anomaly level and triggers local audible/visual alarms;
3. The system generates an alarm record, including time, event type, device number, and other information;
4. Alarm information is pushed in real time to the administrator client and mobile device, notifying relevant personnel for handling;
5. After the administrator resolves the anomaly, the alarm can be manually cleared, and the system retains the handling record.
Chapter 5 Product Technical Parameters
5.1 Cabinet Mechanical Parameters
| Parameter | LA-YSG-12 | LA-YSG-24 | LA-YSG-36 | LA-YSG-60 | LA-YSG-100 | LA-YSG-150 |
|---|---|---|---|---|---|---|
| Key slot positions | 12 positions | 24 positions | 36 positions | 60 positions | 100 positions | 150 positions |
| Cabinet height | 450mm | 650mm | 900mm | 1400mm | 1800mm | 1800mm |
| Cabinet width | 350mm | 350mm | 400mm | 500mm | 600mm | 900mm |
| Cabinet depth | 200mm | 200mm | 250mm | 300mm | 350mm | 350mm |
| Cabinet material | 1.2mm cold-rolled steel | 1.2mm cold-rolled steel | 1.2mm cold-rolled steel | 1.5mm cold-rolled steel | 1.5mm cold-rolled steel | 1.5mm cold-rolled steel |
| Surface treatment | Electrostatic powder coating | Electrostatic powder coating | Electrostatic powder coating | Electrostatic powder coating | Electrostatic powder coating | Electrostatic powder coating |
| Installation method | Wall-mounted | Wall-mounted | Wall-mounted/floor-standing | Wall-mounted/floor-standing | Floor-standing | Floor-standing |
| Total weight | 18kg | 25kg | 35kg | 55kg | 85kg | 120kg |
| Door type | Single door, tempered glass | Single door, tempered glass | Single door, tempered glass | Double door, tempered glass | Double door, tempered glass | Triple door, tempered glass |
| Mechanical lock configuration | 1 emergency mechanical lock | 1 emergency mechanical lock | 1 emergency mechanical lock | 2 emergency mechanical locks | 2 emergency mechanical locks | 3 emergency mechanical locks |
5.2 Electrical Performance Parameters
| Parameter Category | Parameter Item | Technical Specification | Remarks |
|---|---|---|---|
| Power Input | Rated Voltage | AC 100-240V 50/60Hz | Wide voltage adaptation |
| Rated Power | ≤30W (Standby) ≤80W (Peak) | Reference value for 60-position model | |
| Standby Power Consumption | ≤15W | Low power design | |
| Output Power | Main Controller Supply | DC 12V/2A | Stable output |
| Lock Supply | DC 12V/3A | Peak output | |
| Peripheral Supply | DC 5V/1A | USB interface output | |
| Insulation Performance | Insulation Resistance | ≥100MΩ | At normal temperature and humidity |
| Dielectric Strength | AC 1500V/1min no breakdown | Between power supply and enclosure | |
| Ground Protection | Ground Resistance | ≤4Ω | Reliable grounding |
| Backup Power | Rated Capacity | 12V/10Ah | Optional UPS |
| Backup Duration | ≥8 hours (standby) | At full charge | |
| Charging Time | ≤8 hours | Mains float charging |
5.3 Environmental Adaptability Parameters
| Parameter Item | Standard Type | Industrial Enhanced Type | Remarks |
|---|---|---|---|
| Operating Temperature | 0℃ ~ 45℃ | -20℃ ~ 60℃ | Cabinet internal environment |
| Storage Temperature | -10℃ ~ 60℃ | -30℃ ~ 70℃ | Power-off storage state |
| Operating Humidity | 20% ~ 80%RH non-condensing | 10% ~ 90%RH non-condensing | Relative humidity |
| Storage Humidity | 10% ~ 90%RH non-condensing | 5% ~ 95%RH non-condensing | Relative humidity |
| Atmospheric Pressure | 86kPa ~ 106kPa | 80kPa ~ 110kPa | Altitude adaptation |
| Protection Rating | IP30 | IP54 | Cabinet overall |
| Anti-interference Capability | Compliant with GB/T 17626 standard | Compliant with GB/T 17626 industrial-grade standard | Electromagnetic compatibility |
| Seismic Performance | Compliant with highway transport grade | Compliant with railway transport grade | Transport vibration resistance |
5.4 Functional Performance Parameters
| Functional Module | Parameter Item | Technical Specification |
|---|---|---|
| Facial Recognition | Recognition Accuracy | ≥99.9% |
| Recognition Speed | ≤0.5 seconds | |
| Face Capacity | 10,000 faces (expandable) | |
| Liveness Detection | Supports binocular liveness detection | |
| Fingerprint Recognition | Recognition Accuracy | ≥99.8% |
| Recognition Speed | ≤0.3 seconds | |
| Fingerprint Capacity | 5,000 fingerprints | |
| Sensor Type | Semiconductor capacitive | |
| IC Card Recognition | Supported Card Types | M1 card, CPU card, ISO14443A standard card |
| Reading Distance | 0-50mm | |
| Reading Speed | ≤0.2 seconds | |
| Card Capacity | 20,000 cards | |
| RFID Detection | Operating Frequency | 13.56MHz |
| Recognition Accuracy | ≥99.99% | |
| Detection Response Time | ≤0.2 seconds | |
| Tag Type | Passive high-frequency RFID tag | |
| Electric Control Lock | Unlock Time | ≤0.1 seconds |
| Mechanical Life | ≥100,000 cycles | |
| Locking Force | ≥50N | |
| Operating Mode | Normally closed, locked on power failure | |
| Alarm Function | Alarm Volume | ≥85dB |
| Alarm Types | Illegal opening, overtime non-return, door prying, malfunction, etc. | |
| Alarm Methods | Local audible/visual + remote push notification | |
| Data Storage | Local Storage Capacity | 100,000 operation records |
| Record Retention Time | ≥10 years | |
| Data Backup | Local + cloud dual backup |
5.5 Software System Parameters
| Item | Parameter Specification |
|---|---|
| Terminal Operating System | Android 11.0 / Linux embedded system |
| Main Control Chip | RK3568 quad-core 1.8GHz |
| RAM | 2GB DDR4 (4GB on high-configuration model) |
| Storage Capacity | 16GB EMMC (32GB on high-configuration model) |
| Display | 10.1-inch capacitive touch screen, 1280*800 resolution |
| Local Management Client | Supports Windows 7/10/11 systems |
| Cloud Platform | B/S architecture, supports mainstream browser access |
| Number of Management Users | Supports three-level administrators, unlimited quantity |
| Number of Managed Devices | Cloud supports centralized management of unlimited devices |
| Data Synchronization Method | Real-time automatic synchronization, cache and resume on network disconnection |
| Data Encryption | AES-256-bit encrypted transmission and storage |
| Interface Openness | Provides RESTful API interface, supports secondary development |
5.6 Safety Protection Parameters
Physical Security Protection
The cabinet features an anti-pry design with thickened steel plates and anti-pry hinges, resisting conventional forced opening; the electric control lock locks on power failure to prevent unauthorized access during power outages; the mechanical emergency lock uses a customized lock cylinder with an interchange rate of ≤1/10000 to prevent technical unlocking; vibration sensors detect forced prying attempts and trigger alarms in real time.
Information Security Protection
Biometric feature data is encrypted and stored with irreversible conversion, preventing privacy leakage; operation logs are tamper-proof, employing hash verification to ensure data authenticity; multi-level permission management automatically intercepts and records unauthorized operations; network transmission is fully encrypted to prevent data hijacking and theft; operation snapshot capture is supported, retaining on-site operation imagery for traceability.
Electrical Safety Protection
Four-fold power protection: overvoltage, overcurrent, overheating, and short circuit; reliable grounding design to prevent electric shock risks; all electrical components are 3C certified, compliant with national safety standards; low-voltage and high-voltage circuits are separately routed to avoid electromagnetic interference and safety hazards.
6.1 Core Control Functions
6.1.1 Refined Key Control
Independent single-key control: Each key slot is independently locked, independently detected, and independently authorized, achieving single-key level refined management. Users can only access keys within their own permissions, eliminating unauthorized access.
Unique key identity binding: Each key is physically bound to an RFID tag, which cannot be privately removed or swapped, ensuring unique key identity traceability and preventing key substitution.
Real-time presence status display: The touch screen graphically displays the presence status of all keys. Green icons indicate keys in place, red icons indicate keys checked out. The display is intuitive and clear, allowing for quick inventory without opening the cabinet.
Mislocation auto-recognition alarm: When a key is placed in the wrong slot, the system automatically identifies the error and emits an audible/visual alert, requiring the key to be returned to the correct position, preventing key confusion.
6.1.2 Full-Process Recording and Traceability
Automatic operation recording: All check-out, return, door opening, and management operations are automatically recorded, including complete information such as operation time, operator, key number, and operation type, eliminating manual registration.
Multi-dimensional query and traceability: Supports combined queries by time range, personnel name, key number, operation type, and other dimensions, enabling quick location of historical records and clear responsibility traceability.
Tamper-proof logs: Operation records adopt blockchain evidence storage technology (optional) or hash verification mechanism. Once generated, they cannot be modified or deleted, ensuring record authenticity and meeting audit requirements.
Automatic report generation: The system automatically generates daily, weekly, monthly, and quarterly statistical reports, including key usage frequency, personnel borrowing statistics, overtime records, and abnormal alarm data, with Excel export support for management archiving.
6.1.3 Flexible Permission Management
Multi-level permission system: Supports three permission levels: super administrator, department administrator, and regular user. Permissions can be flexibly configured according to organizational structure, enabling hierarchical management.
Time-based permission control: Allows setting permitted borrowing time periods for keys, e.g., keys can only be borrowed during weekday working hours and cannot be accessed outside working hours, adapting to office management rules.
Duration limit control: Allows setting the maximum borrowing duration for each key. Overtime non-return automatically triggers an alarm reminder, preventing keys from being out of control for extended periods.
Temporary permission authorization: Supports temporary authorization functionality. Administrators can temporarily grant visitors and external personnel access permissions to designated keys, set validity durations, and permissions are automatically revoked upon expiration without manual handover.
6.2 Identity Verification Functions
6.2.1 Multi-Modal Recognition Methods
Facial recognition: Binocular liveness facial recognition, fast and accurate, contactless, hygienic, and convenient, suitable for high-frequency usage scenarios.
Fingerprint recognition: Semiconductor fingerprint recognition with high accuracy and simple operation, a classic and reliable identity verification method.
IC card recognition: Compatible with existing work badges and access control cards, achieving one-card access without additional card issuance, reducing usage costs.
Password verification: Numeric password verification serves as a backup verification method, ensuring normal operation under special circumstances.
Combined verification: Supports combined use of multiple verification methods, e.g., “face + password” or “card swipe + fingerprint.” Dual verification further enhances security levels.
6.2.2 Dual-Person Dual-Lock Verification
High-security models support dual-person dual-lock verification. For high-safety-level keys, two authorized personnel must simultaneously verify their identities to open and access keys, complying with the dual-person management system requirements of classified sites and high-risk equipment. Neither person can operate alone, ensuring mutual supervision and eliminating the risk of single-person violations.
6.2.3 Remote Approval Authorization
Online application and approval: Users can submit key borrowing applications through the terminal, computer, or mobile device, specifying the purpose and duration. Approvers conduct remote approval without the need for on-site signatures, making the process efficient and convenient.
Multi-level approval process: Supports multi-level approval. According to key importance, one, two, or three levels of approval can be configured, with step-by-step review for rigorous control.
Emergency remote authorization: In emergency situations, administrators can remotely authorize cabinet opening with one click via mobile device, eliminating the need to be on-site and improving emergency response speed.
6.3 Data Management Functions
6.3.1 Multi-Endpoint Data Synchronization
Local terminal, computer management client, and cloud platform data synchronize in real time. Any operation on one endpoint is immediately updated on all other endpoints, maintaining data consistency.
Offline operation on network disconnection: When the network is interrupted, the terminal can operate independently offline. All operation data is cached locally and automatically synchronized and uploaded after network recovery, without affecting normal use.
6.3.2 Big Data Statistical Analysis
Usage frequency analysis: Analyzes the usage frequency and duration of each key, analyzes key utilization rates, and optimizes key configuration.
Personnel behavior analysis: Analyzes patterns of personnel key borrowing, evaluates work efficiency and compliance, and supports management decision-making.
Abnormal trend analysis: Analyzes trends of abnormal events such as alarms, overtime, and violations, identifies management loopholes, and optimizes control rules in advance.
6.3.3 Data Security Backup
Dual backup mechanism of local + cloud: local storage of operation records with automatic cloud synchronization backup, preventing data loss due to single device failure.
Supports manual data export for backup. Administrators can regularly export and archive data, providing multiple layers of data security.
Data deletion requires multi-level approval, preventing malicious deletion of records and ensuring data integrity.
6.4 Alarm and Security Functions
6.4.1 Multiple Types of Abnormal Alarms
Illegal door opening alarm: Forced opening or prying of the cabinet door without identity verification immediately triggers an audible/visual alarm.
Overtime non-return alarm: When a key is borrowed beyond the set duration and not returned, reminders are automatically pushed to the user and administrator.
Key misplacement alarm: Incorrect key slot placement immediately prompts correction.
Cabinet door open alarm: If the cabinet door remains open beyond the set time after opening, a reminder is issued to prevent forgetting to close the door.
Power failure alarm: When mains power is disconnected and switched to backup power, a power failure alarm notification is pushed to the administrator.
Fault alarm: When internal modules malfunction or sensors are abnormal, a fault alarm is triggered to prompt maintenance.
6.4.2 Multi-Channel Alarm Notifications
Local audible/visual alarm: High-decibel buzzer + warning light flashing on-site, deterring violations and alerting on-site personnel.
Management client pop-up alarm: Local management client and cloud platform display pop-up alarm information with accompanying notification sounds.
Mobile push alarm: Alarm information is pushed to administrator mobile phones via WeChat, SMS, and APP, enabling awareness of abnormal situations anytime, anywhere.
Email alarm: Alarm details are sent to designated email addresses, retaining written notification records.
6.4.3 Video Linkage Snapshot (Optional)
With an optional HD camera, face photos are automatically captured during user operations, bound to operation records, and stored for subsequent traceability and verification.
When an alarm event is triggered, video recording automatically starts, retaining on-site video evidence to provide a basis for responsibility determination.
Can interface with the organization’s existing surveillance system for video linkage and unified storage.
6.5 System Expansion Functions
6.5.1 Multi-Cabinet Cascade Expansion
Supports main cabinet + sub-cabinet cascade mode. One main cabinet can connect to multiple sub-cabinets, infinitely expanding key capacity to meet the massive key management needs of large organizations.
Unified management after cascading: all keys are controlled within the same system, permissions are uniformly assigned, data is uniformly stored, and the operation experience is consistent.
6.5.2 Third-Party System Integration
Provides standard API interfaces supporting integration with OA office systems, access control systems, visitor management systems, vehicle management systems, security platforms, etc., enabling data interchange and linkage control.
For example, integration with a visitor system: after visitor registration, temporary key permissions are automatically granted, and automatically revoked when the visitor leaves; integration with an access control system: after key check-out, corresponding area access permissions are synchronously enabled.
6.5.3 Customized Function Development
Customized exclusive functions can be developed based on user industry characteristics and personalized requirements, such as work ticket linkage for the power industry, joint key control for firearms and ammunition in the military, and dual-person review for narcotic drug keys in hospitals.
Supports customization of cabinet appearance, color, and silkscreen printing to adapt to the visual style requirements of different scenarios.
6.6 Product Core Features
Safe and reliable: Multiple identity verifications, independent lock control, dual detection, and abnormal alarms build a comprehensive security protection system; industrial-grade hardware design is stable and durable with a low failure rate.
Intelligent and efficient: Self-service operation requires no manual attendance; indicator lights guide rapid positioning, making storage and retrieval fast; automatic recording and statistics eliminate manual ledger work, greatly improving management efficiency.
Flexible and adaptable: Multiple models and capacities are available, supporting wall-mounted and floor-standing installation methods; modular software and hardware design allows functions to be selected as needed, adapting to different industry scenarios.
Easy to use and maintain: Touch-based graphical interface is simple and intuitive, usable without professional training; modular hardware design allows rapid replacement of faulty components, making maintenance convenient; software supports remote upgrades for continuous function optimization.
Compliant and traceable: Full-process operations leave records, records are tamper-proof, and reports are automatically generated, meeting various industry regulatory and audit requirements and supporting organizational compliance management.
Green and energy-saving: Low power consumption design with low standby power, supporting sleep energy-saving mode; environmentally friendly materials and processes are used, compliant with green environmental standards.
Guangzhou Lain intelligent key cabinets, with their safe, efficient, and intelligent control capabilities, are widely applied in key management scenarios across various industries. The following provides detailed descriptions of the main application scenarios.
7.1 Government Agencies and Public Institutions
7.1.1 Scenario Pain Points
Government agencies and public institutions manage a large number of keys for office spaces, archive warehouses, computer rooms, classified meeting rooms, and official vehicles. Traditional management models face the following challenges:
- Loose key control in classified areas poses confidentiality breach risks and fails to comply with confidentiality management regulations;
- Official vehicle keys are managed in a decentralized manner, making dispatch inconvenient and private use difficult to monitor;
- Non-standardized key requisition registration makes responsibility tracing difficult, and responsibility cannot be determined when problems arise;
- Lack of complete and standardized key management records during confidentiality inspections and audits makes compliance difficult to achieve.
7.1.2 Solution
Deploy the Guangzhou Lain enhanced intelligent key cabinet with facial recognition + card swipe dual verification, integrated with the organization’s personnel structure, assigning key permissions by department and position:
- Classified warehouse keys are set with dual-person dual-lock verification, strictly implementing confidentiality management regulations;
- Official vehicle keys are centrally controlled, with online application and approval required for vehicle use. The system automatically records usage duration and personnel, eliminating private use;
- All operations leave automatic records, generating tamper-proof record ledgers that meet confidentiality inspection and audit requirements;
- Supports integration with the organization’s OA system, enabling full online process for vehicle application, approval, and key retrieval.
7.1.3 Application Value
Standardizes key management for government agencies, enhances security levels of classified areas, implements official vehicle management regulations, reduces management manpower investment, and achieves standardized, digitalized, and compliant key management, supporting the construction of smart government agencies.
7.2 Public Security, Procuratorate, Court, Judicial, and Military Scenarios
7.2.1 Scenario Pain Points
Key management in public security, procuratorate, court, prison, and military facilities has extremely high security requirements that traditional models cannot meet:
- Keys for armories, evidence rooms, detention areas, and similar zones require high security levels, and single-person management presents integrity and safety risks;
- Duty key handovers are cumbersome, time-consuming during shift changes, and prone to errors;
- Key usage records must meet judicial evidence collection requirements, and manual records lack sufficient legal validity;
- Military camps and outposts are geographically dispersed, making centralized key control difficult.
7.2.2 Solution
Deploy high-security intelligent key cabinets equipped with binocular liveness facial recognition + finger vein recognition, supporting dual-person dual-lock and multi-person approval mechanisms:
- Armory and evidence room keys implement a dual-person dual-lock system requiring two authorized personnel to verify simultaneously before access, ensuring mutual supervision and restraint;
- Duty key shift handovers are completed through the system with one-click handover, automatically recording handover personnel and time for clear traceability;
- Operation records are encrypted and tamper-proof with precise timestamps, meeting judicial evidence standards and serving as traceability basis;
- Cloud platform centralized management enables unified control of equipment at multiple points including camps and outposts, with headquarters able to view key status in real time at all locations.
7.2.3 Application Value
Meets the high security management requirements of public security, procuratorate, court, judicial, and military industries, implements the dual-person management system, mitigates integrity and safety risks, improves shift handover efficiency, and achieves traceable and auditable key management, providing technical support for standardized law enforcement and duty operations.
7.3 Energy, Power, and Industrial Plant Scenarios
7.3.1 Scenario Pain Points
In energy and industrial scenarios such as power plants, substations, petrochemical plants, chemical facilities, and mines, key management is directly related to production safety:
- Unauthorized access to keys for high-voltage distribution rooms, hazardous materials warehouses, and critical equipment could cause major safety accidents;
- Inspection personnel requisition keys for field operations, but traditional registration methods are inefficient and cannot monitor timely returns;
- Large plant areas with keys scattered across workshops and stations make unified management difficult, and inventory is time-consuming and labor-intensive;
- Safety production regulations require traceable key management, and manual records cannot satisfy safety assessment requirements.
7.3.2 Solution
Deploy industrial enhanced intelligent key cabinets adapted to complex plant environments, integrated with work ticket and inspection management systems for linkage control:
- Keys for high-risk areas have strict permission settings — only certified personnel can borrow them, with mandatory work ticket approval linkage; keys cannot be accessed without a work ticket;
- Inspection keys are bound to inspection personnel and inspection routes, with automatic alarm on overtime non-return to prevent keys being left at field sites;
- Multiple stations across the plant are networked via industrial Ethernet, with the central control room monitoring all key statuses and performing one-key inventory;
- The system automatically generates key usage ledgers and interfaces with safety production management systems, meeting safety rating and audit requirements.
7.3.3 Application Value
Strengthens the industrial production safety defense line, standardizes high-risk key control, prevents safety accidents caused by unauthorized operations; improves inspection and maintenance work efficiency; reduces management costs; and perfects safety management ledgers, supporting enterprise safety production standardization.
7.4 Property, Commercial, and Real Estate Scenarios
7.4.1 Scenario Pain Points
Property engineering departments in office buildings, commercial complexes, residential communities, and industrial parks manage a large number of keys, with prominent management challenges:
- Engineering personnel need to requisition various keys for equipment rooms, corridors, and equipment rooms during daily maintenance and inspection — high quantity, high frequency, and low-efficiency manual registration;
- Key verification during shift changes is labor-intensive and prone to omissions and disputes;
- Temporary key custody from property owners and temporary key requisition by outsourced personnel are managed chaotically with unclear responsibility;
- Key loss and unauthorized duplication occur from time to time, posing safety hazards with no way to trace responsible parties.
7.4.2 Solution
Deploy medium-sized intelligent key cabinets at property duty rooms or engineering departments, supporting work badge swipe + password verification:
- Engineering personnel self-service check out keys using work badges, with automatic system recording, eliminating the need for dedicated attendance and improving access efficiency;
- Shift changes use system one-key inventory with clear status display, making handovers fast and accurate while reducing disputes;
- Owner-custodied keys and outsourced personnel keys are set with temporary permissions that automatically expire, eliminating manual recovery;
- Key loss can quickly trace the last person who checked out the key, clarifying responsibility and reducing management risk.
7.4.3 Application Value
Greatly improves property key management efficiency and reduces administrator workload; standardizes key usage procedures, reducing disputes and safety hazards; enhances the standardization level of property services and improves owner experience.
7.5 Transportation, Logistics, and Fleet Scenarios
7.5.1 Scenario Pain Points
For vehicle management scenarios at bus companies, logistics enterprises, car rental companies, and institutional fleets, vehicle key management is the core challenge:
- High vehicle counts with centralized key storage result in inefficient dispatch and access, with queues during peak periods;
- Private vehicle switching by drivers and key mixing are difficult to monitor;
- Vehicle key handovers and substitute driver requisition registration are cumbersome with unclear responsibility; violations and accidents are difficult to attribute;
- Vehicle key loss is costly to replace and affects operational dispatch.
7.5.2 Solution
Deploy large intelligent key cabinets supporting multi-cabinet cascading, integrated with vehicle dispatch management systems:
- Drivers access keys via work badge or facial recognition; the system automatically assigns the corresponding vehicle key, preventing access to other vehicles and eliminating key mixing;
- Dispatchers remotely assign key permissions through the backend, linking scheduling with key requisition to improve dispatch efficiency;
- Key check-in/check-out is automatically recorded and linked with vehicle operation data — violations and accidents can be precisely matched to the responsible personnel;
- Supports 24-hour self-service access, adapting to different shifts including early, late, and night shifts without administrator attendance.
7.5.3 Application Value
Improves fleet dispatch and key access efficiency, adapting to multi-shift operational needs; standardizes vehicle key usage, eliminating private use and key mixing; enables precise responsibility tracing, reduces operational management risks, and achieves intelligent fleet key management.
7.6 Medical, Educational, and Research Scenarios
7.6.1 Medical Industry Scenario
Pain points: Key management for hospital pharmaceutical warehouses, narcotic drug cabinets, laboratory departments, and equipment rooms is strictly regulated. Narcotic drug keys require dual-person management, which is difficult to implement manually; nighttime emergency key access procedures are cumbersome, affecting treatment efficiency; logistics maintenance keys are scattered with chaotic management.
Solution: Deploy high-security intelligent key cabinets. Narcotic drug keys implement dual-person dual-lock verification in compliance with pharmaceutical regulatory requirements; emergency keys are set with exclusive emergency personnel permissions for 24-hour self-service access, ensuring emergency response; logistics keys are centrally controlled, with maintenance personnel using work badges for requisition and automatic recording.
Value: Meets medical industry pharmaceutical safety management standards and implements the dual-person management system; improves emergency and logistics work efficiency, ensuring orderly medical operations.
7.6.2 Education and Research Scenario
Pain points: School laboratories, training rooms, and computer rooms have many keys. Student laboratory key requisition management is inconvenient, and teacher supervision workload is heavy; classified laboratories and precision instrument rooms at research institutes require high key security; library and teaching building keys are scattered, making inventory difficult.
Solution: Deploy standard intelligent key cabinets. Students use campus cards to requisition laboratory keys, with automatic system recording and teacher backend supervision; classified research facilities use enhanced verification with strict permission control; campus-wide multi-point networking enables unified management and inventory.
Value: Reduces teacher management burden, standardizes laboratory key usage, ensures the safety of research facilities and equipment, and improves campus management intelligence.
7.7 Financial Banking and Insurance Scenarios
7.7.1 Scenario Pain Points
Key management at bank branches, vaults, and insurance companies requires extremely high security levels:
- Keys for vaults, cash boxes, and archives require strict control, making dual-person management system implementation difficult;
- Numerous widely distributed branches make central management of branch keys challenging, with no real-time visibility of status;
- Key handover and rotation management processes are cumbersome, and manual records are prone to loopholes;
- High regulatory audit requirements demand complete and traceable key management records.
7.7.2 Solution
Deploy financial-grade high-security intelligent key cabinets with multiple biometric recognition, integrated with bank security systems:
- Vault and critical warehouse keys implement dual-person dual-lock + remote approval mechanisms, strictly implementing the dual-person management system — no single person can operate;
- All branch equipment is networked, enabling the head office monitoring center to view key status at all branches in real time and conduct remote supervision;
- During personnel rotation or position adjustments, the system can adjust permissions with one click, with online handover processes and complete records;
- Operation logs are permanently stored and tamper-proof, meeting banking regulatory audit and inspection requirements.
7.7.3 Application Value
Meets the high-security control requirements of the financial industry, implements regulatory systems, and prevents internal operational risks; achieves centralized key management across all branches, improving supervision efficiency; perfects compliance ledgers to successfully pass various audits and inspections.
7.8 Other Niche Industry Scenarios
7.8.1 Hotel and Homestay Scenario
Manages guest room, linen room, and equipment room keys with front-desk self-service access, reducing front-desk workload; supports temporary guest authorization, adapted to homestay and apartment short-rental scenarios where guests self-service check out and return keys without manual handover.
7.8.2 4S Dealership and Auto Repair Scenario
Manages test drive vehicle and repair vehicle keys with automatic test drive registration, preventing test drive disputes; centralized control of repair workshop keys to prevent loss and confusion; integrates with DMS systems for work order and key requisition linkage.
7.8.3 Museum and Cultural Tourism Scenario
Manages cultural relic warehouse, exhibition hall, and equipment room keys with strict permission control to ensure cultural relic safety; supports linkage with security systems where abnormal operations trigger security response plans; time-based authorization for visiting passage keys, adapted to opening hours management.
7.8.4 Mining and Construction Site Scenario
Manages blasting equipment warehouse, site equipment, and project department keys, adapted to outdoor complex environments; construction personnel use real-name cards for requisition with clear records, implementing safety production responsibilities; multi-work-area networked management with headquarters remote supervision.
8.1 Pre-Installation Preparation
8.1.1 Technical Documentation Preparation
Before installation, the following technical documentation must be collected and reviewed:
- This “Intelligent Key Cabinet Installation, Wiring, and Commissioning Manual”;
- Product packing list and factory inspection report;
- On-site construction drawings and point layout diagrams;
- On-site power distribution and network layout drawings;
- Customer-confirmed installation plan and technical requirements.
Construction personnel must carefully study the documentation, clarify equipment models, installation methods, wiring requirements, and commissioning standards to ensure the construction process complies with specifications.
8.1.2 Construction Tool Preparation
Prepare corresponding construction tools based on the installation method. The standard installation tool list is as follows:
| Tool Category | Tool Name | Specification | Purpose |
|---|---|---|---|
| Measuring Tools | Steel tape measure | 5m | Measuring installation position, marking hole positions |
| Level | Magnetic spirit level | Checking cabinet installation levelness | |
| Marker | / | Marking drilling positions | |
| Drilling Tools | Impact drill | Rotary hammer/impact drill | Drilling holes in walls and floors |
| Drill bits | M8, M10 impact drill bits | Corresponding to expansion bolt drilling | |
| Vacuum cleaner/brush | / | Cleaning drilling dust | |
| Fastening Tools | Wrench | Adjustable wrench/socket wrench | Tightening expansion bolt nuts |
| Screwdriver | Phillips and flat-head screwdrivers | Fixing accessories, wiring terminals | |
| Hex key | Set | Fastening hex socket screws | |
| Wiring Tools | Wire stripper | / | Stripping insulation from conductors |
| Crimping tool | Ferrule crimping pliers | Crimping wire terminals | |
| Cable tester | Network cable tester | Testing network cable continuity | |
| Auxiliary Tools | Step ladder | 1.5-2m | Elevated installation work |
| Gloves | Work gloves | Construction protection | |
| Electrical tape | / | Insulation wrapping | |
| Cable ties | / | Organizing and binding cables |
8.1.3 On-Site Environment Survey
An on-site environment survey must be conducted before installation to confirm the following conditions:
Installation position confirmation: Confirm that the installation point meets user usage requirements, the position is reasonable, access is convenient, and the area is free from moisture, direct sunlight, and strong electromagnetic interference; reserve sufficient door opening and operating space — at least 80cm of operating space in front of the cabinet door.
Installation surface confirmation:
- Wall-mounted installation: confirm wall material (brick wall, concrete wall, hollow wall, etc.), load-bearing capacity ≥50kg. Lightweight walls such as hollow walls and drywall cannot be directly wall-mounted and require reinforcement;
- Floor-standing installation: confirm the floor is level and solid, load-bearing capacity ≥200kg, with no obvious inclination or depression.
Power supply condition confirmation: A reliable 220V mains outlet is available near the installation point with proper grounding, and power supply capacity meets equipment power requirements; it is recommended to connect to a dedicated circuit, avoiding shared circuits with high-power equipment.
Network condition confirmation: Confirm network points. For wired networks, reserve network ports; for wireless networks, confirm signal coverage strength; obtain network parameters (IP address, gateway, DNS, etc.) in advance.
Environmental condition confirmation: On-site temperature and humidity are within equipment operating ranges, with no corrosive gases, no flammable or explosive materials, and good ventilation.
8.1.4 Arrival and Unpacking Inspection
After equipment arrival and before installation, an unpacking inspection must be conducted:
- Check whether the outer packaging is intact with no collision or water damage marks, confirming no damage during transportation;
- Check equipment main unit, accessories, and documentation one by one against the packing list for quantity and model, confirming completeness and correctness;
- Inspect the cabinet exterior for paint chipping, deformation, or glass damage, and check door locks and hinges for integrity;
- Check the equipment nameplate information to confirm model, serial number, and date of manufacture match the order;
- Unpacking inspection must be conducted with representatives from both parties present. Sign to confirm after inspection. If damage or missing parts are found, contact the manufacturer promptly for handling.
8.2 Installation Environment Requirements
To ensure stable equipment operation and service life, the installation environment must meet the following requirements:
Temperature and humidity requirements: Ambient temperature 0℃~45℃, relative humidity 20%~80%, non-condensing; avoid installation near direct air conditioning airflow, heating sources, or direct sunlight to prevent sudden temperature changes and condensation.
Space requirements: Reserve ≥50mm heat dissipation space on both sides of the cabinet, ≥30mm wiring space at the rear, and ≥80cm operating space in front, ensuring the cabinet door can open fully with smooth operation.
Electrical environment requirements:
- Stable power supply voltage with fluctuation range not exceeding ±10% of rated voltage;
- Reliable grounding with ground resistance ≤4Ω; grounding to water pipes, heating pipes, or other piping is prohibited;
- Keep away from strong electromagnetic interference sources such as high-power motors, transformers, and variable frequency drives to prevent electromagnetic interference affecting equipment operation.
Physical environment requirements:
- Stable installation position with no vibration or shaking;
- Avoid installation in damp, dusty, or corrosive gas environments such as bathrooms, kitchens, and chemical plants;
- Keep away from water sources and fire sources to avoid water damage and fire risks.
Safety requirements:
- Installation position does not block fire protection equipment or evacuation routes;
- Wall-mounted installation height should be moderate, with the operation panel center at 1.4-1.5m from the ground, in line with ergonomics for convenient operation;
- Standardized cable routing to avoid exposed cables causing tripping hazards, with proper protective measures in place.
8.3 Wall-Mounted Installation Procedure
Wall-mounted installation applies to 12-position, 24-position, 36-position, and 60-position models. The installation steps are as follows:
Step 1: Positioning and Marking
- Determine the installation position based on the site layout, and mark the cabinet’s installation center point with a marker;
- Place the cabinet back panel against the wall, adjust the position to level the cabinet, and calibrate with a spirit level;
- Mark all drilling positions on the wall using a marker through the mounting holes on the back panel;
- Move the cabinet away and re-verify hole spacing and dimensions to ensure accurate marking.
Step 2: Drilling
- Select the corresponding drill bit based on the expansion bolt specification: φ8 drill bit for M8 expansion bolts, φ10 drill bit for M10;
- Hold the impact drill perpendicular to the wall and drill, with hole depth slightly deeper than the expansion bolt length, generally 60-80mm;
- After drilling, clean dust from the holes using a brush or vacuum cleaner to avoid affecting expansion performance;
- Check hole depth and diameter to ensure expansion bolts can be fully inserted without looseness.
Step 3: Installing Expansion Bolts
- Assemble the expansion bolt sleeve and screw, and insert vertically into the drilled hole;
- Lightly tap the top of the bolt with a hammer to fully insert the expansion sleeve into the hole, making the bolt end flush with the wall surface;
- Initially tighten with nuts to ensure the bolts are secure, taking care not to overtighten to facilitate subsequent cabinet alignment.
Step 4: Cabinet Mounting and Securing
- With two people working together, lift the cabinet and align the rear mounting holes with the expansion bolts, then mount smoothly;
- Install all nuts in sequence, and re-calibrate cabinet levelness and verticality with a spirit level;
- After adjusting the cabinet to fully level and plumb, tighten all nuts uniformly with a wrench to ensure the cabinet is firmly secured without shaking;
- Gently push the cabinet to test stability, confirming secure installation without looseness or inclination.
Step 5: Post-Installation Inspection
- Open and close the cabinet door to check smooth operation with no abnormal noise, no binding, and tight closure;
- Check cabinet levelness with no deviation exceeding 2mm/m;
- Check that mounting screws are secure, without looseness, and the cabinet has no deformation;
- Clean up the installation site, keeping the environment tidy.
8.4 Floor-Standing Installation Procedure
Floor-standing installation applies to 36-position, 60-position, 100-position, and 150-position models. The installation steps are as follows:
Step 1: Position Determination and Floor Leveling
- Move the cabinet to the predetermined installation position and adjust the general orientation;
- Rotate the four adjustable leveling feet at the bottom, using a spirit level to adjust cabinet levelness and verticality;
- First adjust front-to-back level, then left-to-right level, calibrating repeatedly until the spirit level bubble is centered;
- Ensure all four feet bear load evenly, and the cabinet is stable without shaking or inclination.
Step 2: Floor Reinforcement and Securing (Optional)
- For high-traffic or high-security scenarios, optional floor expansion bolt fixing is available:
- Move the cabinet and mark the floor positions corresponding to the bottom fixing holes;
- Drill holes in the floor and install expansion bolts;
- Return the cabinet to position, align bolt holes, and tighten nuts to secure;
- Re-calibrate levelness.
Step 3: Post-Installation Inspection
- Test cabinet stability by pushing the upper portion with force — there should be no obvious shaking or inclination;
- Test cabinet door opening and closing — the door should operate smoothly, close tightly, and have uniform door gaps;
- Check that leveling feet bear load evenly with no suspension;
- Confirm appropriate cabinet height with operation panel height in line with ergonomics.
8.5 Combined Cascade Installation Procedure
When single-cabinet capacity is insufficient, a main cabinet + sub-cabinet combined cascade installation can be adopted, with the following steps:
Layout positioning: Arrange the main cabinet and sub-cabinet positions according to the design drawings. The main cabinet is generally positioned on the left or in the middle, with sub-cabinets arranged in sequence. Cabinets should fit closely together with aligned levels and heights.
Cabinet securing: Secure the main cabinet and sub-cabinets one by one using either wall-mounted or floor-standing installation methods, ensuring all cabinets are on the same horizontal plane, neatly aligned, with uniform door gaps.
Cascade wiring: Connect the cascade interfaces between the main cabinet and sub-cabinets using dedicated RS485 cascade cables, using a daisy-chain series connection with total bus length not exceeding 1000 meters; pay attention to A/B wire sequence correspondence during wiring — do not reverse.
Power supply wiring: Each cabinet can be powered independently, or a centralized power supply method can be used, ensuring sufficient power capacity; when using centralized power supply, the power cable gauge must meet total power requirements to avoid excessive voltage drop.
Cascade testing: After power-on, add sub-cabinet devices in the main cabinet system and test main-sub cabinet communication, verifying that sub-cabinet locks, indicator lights, and sensors can be controlled by the main cabinet, and that cascade functions operate normally.
8.6 Installation Quality Inspection Standards
After installation is complete, quality inspection shall be conducted according to the following standards. Only after all items pass may the process proceed to wiring and commissioning:
| Inspection Item | Inspection Standard | Inspection Method |
|---|---|---|
| Cabinet appearance | No paint chipping, no scratches, no deformation, no glass damage | Visual inspection |
| Cabinet levelness | Horizontal deviation ≤2mm/m, vertical deviation ≤2mm/m | Spirit level, plumb line measurement |
| Installation firmness | Wall-mounted: load-bearing ≥50kg without looseness; floor-standing: no obvious shaking when pushed | Manual testing, load-bearing testing |
| Cabinet door operation | Smooth opening/closing, no binding, no abnormal noise, tight closure, uniform door gap ≤2mm | Manual open/close testing, feeler gauge measurement |
| Mechanical lock | Emergency key inserts and removes smoothly, locking/unlocking functions normal | Key operation testing |
| Cable routing standard | Cables neat, concealed routing, no exposed conductors, securely bound | Visual inspection |
| Site environment | Installation position meets requirements, no safety hazards around, site clean | Visual inspection |
9.1 Pre-Wiring Preparation and Safety Regulations
9.1.1 Wiring Preparation
Technical preparation: Familiarize with the equipment wiring schematic diagram, clarify all interface definitions, wire sequence requirements, and voltage levels to avoid wiring errors that could damage equipment.
Material preparation: Prepare power cables, network cables, cascade cables, terminal blocks, ferrule terminals, electrical tape, cable ties, wire number sleeves, and other materials. Cable specifications must meet design requirements.
Tool preparation: Prepare wire strippers, crimping tools, screwdrivers, multimeters, cable testers, and other tools with proper insulation.
Safety preparation: Confirm the wiring power supply is in the disconnected state, with a “Do Not Close” tag posted; wear insulated protective equipment; confirm the wiring environment is dry and safe.
9.1.2 Wiring Safety Regulations
Power-off operation: All wiring work must be performed with power disconnected. Live wiring is strictly prohibited to prevent electric shock and short-circuit damage to equipment.
Correct wire sequence: Strictly follow the wiring diagram. Positive/negative poles and signal wire sequences must not be reversed. Separate high-voltage and low-voltage circuits to avoid module damage from incorrect connections.
Secure wiring: Terminal connections must be tightened, crimped terminals must be firmly crimped without looseness or false contact, preventing faults caused by poor contact.
Insulation protection: Exposed wire cores must be properly insulated to prevent short circuits; high-voltage wiring terminals must be fitted with insulation covers to prevent electric shock.
Reliable grounding: Equipment protective grounding must be reliably connected with ground resistance meeting requirements, ensuring electrical safety.
Clear identification: Wire number sleeves must be installed at both ends of cables with clear markings for subsequent maintenance and troubleshooting.
Voltage verification: After wiring is complete, first use a multimeter to check for short circuits and incorrect connections. Only after confirming correctness may power-on testing proceed.
9.2 Power Supply System Wiring
9.2.1 Mains Input Wiring
Standard adapter wiring:
- Insert the power adapter’s DC output plug into the power input interface on the cabinet rear panel, fully seated;
- Insert the power adapter’s AC input plug into the mains outlet with good contact;
- Place the adapter in a ventilated, dry location, avoiding coverage to facilitate heat dissipation.
Hard-wire connection method (engineering grade):
- Disconnect the mains circuit power and verify no voltage is present;
- Open the terminal compartment on the cabinet rear, locate the power input terminal block marked L (line), N (neutral), PE (ground);
- Strip the insulation from the power cable ends to approximately 8mm and crimp ferrule terminals;
- Connect the line wire to the L terminal, neutral wire to the N terminal, and ground wire to the PE terminal, tightening each screw one by one to ensure firm contact;
- Pull test the cables to verify no looseness, organize the cables, and secure with cable ties.
9.2.2 Internal Power Distribution Wiring
Internal power distribution wiring has been completed at the factory and generally requires no on-site modification. If external peripherals need to be added, wire according to the following specifications:
- Locate the spare output terminals on the internal power distribution board and confirm the output voltage (DC12V or DC5V) matches the peripheral device;
- Connect positive/negative poles correspondingly: red wire to positive, black wire to negative — do not reverse;
- After wiring, install insulating sleeves and secure with ties to prevent cable movement and disconnection.
9.2.3 UPS Backup Power Wiring (Optional)
- Turn off the equipment main power and disconnect mains;
- Open the internal UPS installation compartment and place the UPS battery pack in the fixed position;
- Connect the UPS input terminals to the mains input and output terminals to the equipment power input;
- Connect the battery pack wires: red to positive, black to negative, correspondingly connected and tightened at terminals;
- After wiring is complete, verify all connections, close the mains switch, and the UPS will automatically enter float charging state.
9.2.4 Power Wiring Inspection
- Use a multimeter in resistance mode to measure resistance between L-N, L-PE, and N-PE; no short circuit should be present;
- After power-on, use a multimeter in voltage mode to measure input voltage, which should be within the rated range;
- Measure the voltage between the equipment enclosure and ground; it should be ≤36V safe voltage, confirming proper grounding;
- Check that the power indicator is lit and the equipment powers up and starts normally.
9.3 Network Communication Wiring
9.3.1 Wired Network Wiring
Direct Ethernet Connection Method:
Prepare a Cat5e or Cat6 network cable, crimp RJ45 connectors on both ends, using T568B wiring sequence;
Use a cable tester to verify continuity of the network cable, all 8 cores must be continuous, wire sequence correct;
Insert one end of the network cable into the RJ45 port on the rear of the cabinet, connect the other end to a LAN switch or information outlet, press the clip firmly until it locks.
Terminal Block Method:
Some industrial models use terminal-type network interfaces; strip the outer sheath of the network cable and connect the wires to the terminal block according to the wiring sequence;
T568B wiring sequence: Orange-white, Orange, Green-white, Blue, Blue-white, Green, Brown-white, Brown;
Tighten each core individually, ensure no looseness, no short circuit, and verify continuity with a tester.
9.3.2 Wi-Fi Module Wiring (Optional)
Open the main control compartment and locate the Wi-Fi module interface on the mainboard;
Connect the Wi-Fi antenna to the module’s antenna socket, tighten the connector, position the antenna against the internal metal wall of the cabinet, and adjust its orientation;
Insert the Wi-Fi module into the corresponding slot and secure it firmly;
After powering on, configure the Wi-Fi parameters in the system settings to connect to the appropriate wireless network.
9.3.3 4G Module Wiring (Optional)
Remove the 4G module and insert a Nano SIM card, chip facing down, notch aligned, snap the card holder closed;
Insert the 4G module into the corresponding interface on the mainboard and secure with screws;
Connect the 4G antenna, route it to the top of the cabinet or a location with good signal strength, and secure it firmly;
After powering on, check the network status; when the 4G signal is normal, the network connection is successful.
9.3.4 Network Wiring Inspection
Wired Network: Check the network port indicator lights — green light steady ON indicates a normal connection, yellow light flashing indicates data transmission; check the IP address in the system network settings and ping the gateway to test connectivity.
Wireless Network: Check the Wi-Fi connection status in the system, confirm the IP address is obtained normally, and test external network access.
4G Network: Check signal strength, ≥2 bars is considered normal; network connection successful, data can be uploaded normally.
9.4 Identity Recognition Module Wiring
The identity recognition module has completed internal wiring at the factory. If on-site replacement or module addition is required, perform wiring according to the following specifications:
9.4.1 Facial Recognition Module Wiring
The facial recognition module uses USB interface communication, powered by DC5V;
Insert the module’s USB connector into the corresponding USB port on the main control board, press firmly to secure;
Adjust the camera angle to face the operator’s face position, and secure the module bracket;
After powering on, test that the facial recognition function operates normally and the image is clear.
9.4.2 Fingerprint Module Wiring
The fingerprint module uses serial communication, powered by DC3.3V;
Connect according to the wiring sequence: VCC to power positive, GND to power ground, TX to mainboard RX, RX to mainboard TX;
Ensure connections are secure, insulation is intact, and secure the fingerprint sensor at the corresponding position on the panel;
After powering on, test that fingerprint enrollment and recognition functions operate normally.
9.4.3 IC Card Reader Module Wiring
The card reader module uses Wiegand or serial communication, powered by DC5V;
Connect the power lines and communication lines accordingly; for the Wiegand interface, ensure D0 and D1 wiring sequence is not reversed;
Secure the card reader module on the panel’s card reading area, ensuring close contact with the panel;
Test that card swiping recognition operates normally and the reading distance meets parameter requirements.
9.5 Lock Control and Detection Module Wiring
The lock control and detection module has completed internal wiring at the factory. When cascading expansion, slave cabinet wiring is required:
Connect the cascade output port of the master cabinet’s lock control board to the cascade input port of the slave cabinet’s lock control board, using RS485 bus;
Connect bus A to A, B to B, GND to GND — do not reverse;
Connect a 120Ω termination resistor at the end of the bus to ensure stable communication;
Each slave cabinet must have a unique address code, set via DIP switches, and must not be duplicated;
After powering on, test that the master cabinet can normally control all locks in slave cabinets and status feedback is normal.
9.6 Alarm Peripheral Wiring
9.6.1 External Audible and Visual Alarm Wiring
The external alarm is generally powered by DC12V; connect positive and negative terminals to the alarm output terminals accordingly;
The alarm output is a switching (dry contact) signal, connected in series with the alarm power supply circuit;
Install the alarm on the top of the cabinet or on the wall, facing personnel activity areas;
Test that when the alarm is triggered, the alarm sounds and flashes normally, and the volume meets requirements.
9.6.2 Door Magnetic Contact, Smoke Detector and Other Detector Wiring
Connect detectors to the alarm input terminals; support both normally open (NO) and normally closed (NC) signals, configurable through system settings;
Two-wire detectors do not distinguish polarity; four-wire detectors distinguish between power and signal lines;
Secure detectors at corresponding positions — door magnetic contacts installed at the matching positions on the cabinet door and cabinet body, smoke detectors installed on the top of the cabinet;
Simulate alarm triggering to test that the system can correctly receive alarm signals and respond accordingly.
9.7 Third-Party System Integration Wiring
9.7.1 Access Control System Integration
Use RS485 or TCP/IP protocol for integration, wiring according to the communication protocol agreed upon by both parties;
The access control system outputs card swipe signals to the key cabinet, enabling card-swipe-linked door opening for key retrieval;
The key cabinet outputs relay signals to the access control system, enabling door access linkage after key retrieval;
After wiring, test that the linkage logic is correct and data synchronization is normal.
9.7.2 Fire Protection System Integration
Connect the fire alarm linkage signal, using passive switching (dry contact) signals;
When a fire alarm occurs, the key cabinet can be configured to unlock all cabinet doors or lock down the system, in coordination with fire emergency procedures;
After wiring, simulate a fire signal to test that the linkage function operates normally.
9.8 Wiring Inspection and Insulation Testing
After all wiring is complete, a comprehensive inspection and testing must be performed before power-on commissioning is permitted:
Visual Inspection: All wiring is neat, securely bundled, clearly labeled, no exposed conductors, and power and signal wiring are routed separately.
Continuity Test: Use the continuity mode of a multimeter to test each circuit for proper conduction — no open circuits, no loose connections.
Insulation Test: Use a megohmmeter (insulation resistance tester) to test that the insulation resistance of power circuits to ground is ≥100MΩ, meeting insulation requirements.
Short Circuit Test: With power off, measure the resistance between positive and negative power terminals — no short circuit condition.
Wire Sequence Verification: Check signal wire sequences one by one to confirm no reversed or incorrect connections.
Grounding Test: Test that the protective ground connection is properly conductive, with grounding resistance ≤4Ω.
10.1 Pre-Commissioning Preparation
10.1.1 Commissioning Condition Confirmation
Equipment installation and wiring are fully completed; installation quality and wiring inspection have passed;
Mains power supply is normal, voltage stable, grounding reliable;
Network lines are clear and unobstructed, network parameters are complete;
Commissioning computer is prepared, with corresponding management software installed;
All accessories, key fobs, and test cards are available;
Commissioning personnel are familiar with equipment operation and system settings, and understand the commissioning process.
10.1.2 Commissioning Tools and Documentation
One commissioning computer, Windows system, with Ethernet port;
Multimeter, cable tester;
Test IC cards, administrator password;
Software installation package, operation manual;
Commissioning record form, for recording the commissioning process and results.
10.2 Single-Unit Power-On Commissioning
10.2.1 Final Pre-Power-On Inspection
Re-confirm all wiring is correct, no short circuits or incorrect connections;
Confirm the power switch is in the OFF position;
No tools, screws, wire trimmings or other debris left inside the cabinet, to prevent short circuits;
Cabinet doors are in the closed position.
10.2.2 Power-On Startup Test
Close the mains power switch to energize the equipment;
Turn on the main power switch at the rear of the cabinet and observe the equipment startup process:
Power indicator lights illuminate, each module powers up progressively;
Touch screen lights up and enters the system boot screen;
Slot indicator lights complete a self-test sequence (illuminating one by one), then return to normal status;
The buzzer emits a single “beep” sound, indicating startup is complete.
Observe the startup process for any abnormalities, such as abnormal noise, smoke, unusual odor, screen failure, etc. If any abnormality is found, immediately cut off power and troubleshoot.
Record the startup time — normal startup time should be ≤30 seconds.
10.2.3 System Initial Screen Inspection
After system startup is complete, the standby main interface is displayed;
Check that the interface displays normally, touch operation is responsive, with no lag or screen artifacts;
Check that the time and date display is correct; if incorrect, adjust in settings later;
Check that the status bar shows power, network, and device status as normal.
10.3 Hardware Function Module Commissioning
10.3.1 Display and Touch Module Commissioning
Tap various areas of the screen to test touch response accuracy — no drift, no dead zones;
Adjust screen brightness and volume, test that adjustment functions operate normally;
Leave the screen lit for an extended period to check for no flickering, no dead pixels, and stable display.
10.3.2 Identity Recognition Module Commissioning
Facial Recognition Commissioning:
Enter administrator mode and enroll test face data;
Test recognition from different angles and distances — recognition speed should be fast and accuracy high;
Test with photos and video attacks — liveness detection must function properly and reject them;
Test in low-light environments — recognition function must operate normally.
Fingerprint Recognition Commissioning:
Enroll test fingerprints, test with different fingers;
Test recognition with dry and wet fingers — success rate ≥98%;
Test with fake fingerprints — they must not pass verification.
IC Card Commissioning:
Enroll test card numbers;
Test card swiping — recognition should be fast and accurate, reading distance meeting parameters;
Test card swiping at different angles — recognition should be stable.
Password Verification Commissioning:
Set a test password, enter the password to verify it passes;
Test with incorrect passwords — verification must fail with appropriate prompts.
10.3.3 Lock Control and Indicator Light Commissioning
Enter the system test mode and test each slot’s electric lock unlock and lock functions one by one — operation should be smooth with no abnormal noise;
Test each slot’s indicator lights — red, green, and yellow statuses display normally, with uniform brightness;
Test the lock unlock duration — default 5 seconds for automatic re-locking, timing accurate;
Perform 10 consecutive lock/unlock cycles — no jamming, no failures, stable performance.
10.3.4 Presence Detection Module Commissioning
Place key fobs into corresponding slots one by one — system displays correct presence status, indicator lights turn green;
Remove a key — system immediately displays absence status, indicator light turns red, with timely response;
Test incorrect key placement — system identifies the misplaced key and triggers an alarm alert;
Test covering the photoelectric sensor — dual detection logic operates normally with no false judgments.
10.3.5 Alarm Module Commissioning
Simulate illegal door opening — forcibly open the cabinet door, triggering audible and visual alarm, system records the alarm information;
Simulate overtime non-return — set a short borrowing duration, trigger an alarm reminder after timeout;
Test alarm volume and lights operate normally, and alarm reset function works;
Test vibration sensor — lightly tap the cabinet; when threshold is reached, alarm is triggered.
10.3.6 Power Module Commissioning
Test mains power supply mode — equipment operates stably;
Disconnect mains power, test UPS transfer — seamless switchover, equipment does not restart, battery runtime normal;
Test the emergency power interface — external power bank can supply power for normal startup and operation.
10.4 Software System Configuration Commissioning
10.4.1 Basic System Settings
Set system time and date, calibrate accurately;
Set device name and device number for easy management and identification;
Set language, volume, brightness, sleep time and other parameters to suit the application scenario;
Set administrator account and password, change the default password to ensure security.
10.4.2 Network Parameter Configuration
Wired Network Configuration:
Enter network settings, select wired network;
Set IP address, subnet mask, gateway, DNS — select DHCP auto-acquisition or static IP;
Save settings, test network connectivity — ping gateway and external network normally.
Wireless Network Configuration:
Enable Wi-Fi, search for nearby wireless networks;
Select the corresponding SSID, enter the password, connect to the network;
Test successful connection and normal data transmission.
4G Network Configuration:
Insert SIM card, enable mobile data;
Check signal strength, network connection successful;
Test normal external network access.
10.4.3 Management Terminal Connection Commissioning
Install local management software on the computer, following the wizard to complete installation;
Connect the computer and device to the same LAN, ensure network interoperability;
Open the management software, search for devices, and add the corresponding device;
Test successful connection — device status can be viewed in real-time, data synchronization normal.
10.5 Key Tag Binding Commissioning
10.5.1 Key Tag Enrollment
Prepare all keys requiring management with corresponding RFID key fobs;
Securely bind keys to key fobs using stainless steel wire, crimped securely so they cannot be easily removed;
In the management system, enter the key management interface and select “Add Key”;
Hold the key fob near the card reading area to read the tag ID and enroll it into the system;
Fill in key name, number, assigned department, location, remarks and other information;
Enroll all keys one by one; after completion, verify the quantity and information to ensure accuracy.
10.5.2 Slot Binding and Learning
Enter slot learning mode — system automatically scans all slots;
Place the bound key fobs into the corresponding numbered slots one by one;
System automatically identifies the tag ID and slot correspondence, completing the binding;
After all bindings are complete, test by removing and inserting keys one by one — slot and key correspondence is correct, no false reports.
10.5.3 Batch Import and Export
Support Excel spreadsheet batch import of key information to improve enrollment efficiency;
Export key information lists for verification and backup;
Test that batch import functions operate normally and data is accurate.
10.6 Permission System Configuration Commissioning
10.6.1 User Information Enrollment
Enter the user management interface and add users;
Enter user name, employee number, department, position, contact information and other details;
Collect user biometric features (face, fingerprint) or enroll card numbers, set passwords;
Set user permission levels (super administrator, department administrator, regular user);
Support batch import of user information via Excel for improved efficiency.
10.6.2 Key Permission Assignment
Select the corresponding user and assign keys that can be borrowed;
Set borrowing rules: allowed borrowing time periods, maximum borrowing duration, whether approval is required;
Batch assign permissions by department — users in the same department receive the same key permissions;
Set temporary permissions with specified validity periods, automatically expiring upon expiration.
10.6.3 Permission Function Verification
Log in with a regular user account — verify that only authorized keys are displayed, unauthorized keys cannot be operated;
Test during non-authorized time periods — key retrieval is denied with a notification that the current time is outside the permitted window;
Test the approval process — submit a request, and retrieval is only allowed after approval is granted;
Test the dual-person dual-lock function — single-person verification cannot open, dual-person simultaneous verification passes.
10.7 Network Linkage Commissioning
10.7.1 Multi-Cabinet Cascade Commissioning
Add all slave cabinet devices on the master cabinet, set the corresponding address codes;
Test that the master cabinet can view key status of all slave cabinets in real-time;
Test that key access operations for slave cabinets can be performed from the master cabinet — functions normal;
Test that operation records from all cabinets are synchronized uniformly to the management terminal;
After cascading multiple cabinets, the system operates stably with no communication delays or packet loss.
10.7.2 Cloud Platform Commissioning
Configure the device with the cloud server address and register the device to the cloud platform;
The cloud platform can view the device as online, with real-time synchronization of key status and operation records;
Test cloud-based remote approval, remote door opening, and remote configuration functions;
Test alarm information push to the cloud platform — notification functions normal;
Test centralized management of multiple devices and data statistics/analysis functions.
10.7.3 Third-Party System Integration Commissioning
Configure interface parameters according to the integration protocol;
Test bidirectional data exchange — access control card swiping can trigger key cabinet verification;
Test that after OA system approval is granted, key permissions are automatically synchronized;
Test linkage with the surveillance system — operations trigger video recording and snapshot capture;
Perform full-process linkage testing — logic correct, response timely.
10.8 Emergency Function Commissioning
10.8.1 Mechanical Emergency Unlock Commissioning
Locate the emergency lock cylinder on the cabinet door and insert the mechanical emergency key;
Rotate the key — the cabinet door opens normally, lock releases smoothly;
Close the cabinet door, rotate the key back to the locked position — locking operates normally;
Test that the emergency locks on all cabinet doors are functional.
10.8.2 Power Failure Emergency Commissioning
Disconnect mains power — device switches to UPS power, operating normally;
Before UPS battery is depleted, test external power bank emergency power supply — device can start and operate normally;
In power-off condition, the mechanical emergency key can still open the cabinet door to retrieve keys.
10.8.3 System Failure Emergency Commissioning
Simulate a system crash — press the reset button to restart the device; system starts normally, data is not lost;
Test the administrator forced unlock function — remote forced door opening is available for emergency situations.
10.9 Integrated Commissioning and Performance Testing
10.9.1 Complete Access/Return Flow Testing
Simulate a regular user’s complete key retrieval process: Identity verification → Door opens → Retrieve key → Close door — entire process is smooth, records accurate;
Simulate a complete key return process: Select return → Verify key → Door opens → Place key → Close door — process is smooth, status updates correct;
Perform 100 consecutive access/return operations — no failures, no incorrect records; system is stable.
10.9.2 Concurrent Stress Testing
Multiple users operating continuously — test system response speed, no lag or delays;
Multiple cabinets operating simultaneously — test system concurrency processing capability, no data confusion;
Under high-frequency operation, no overheating, no crashes — equipment operates stably.
10.9.3 Abnormal Scenario Testing
Illegal operation tests: Forced door opening, incorrect key placement, timeout, violent operation — all must trigger correct alarm alerts;
Environmental interference tests: Minor electromagnetic interference, voltage fluctuations — equipment operates stably;
Misoperation tests: Various erroneous operations — system provides clear prompts, no crashes or data corruption.
10.9.4 Data Accuracy Testing
Verify that the operation record count matches the actual number of operations — no missing records, no duplicate records;
Verify record information accuracy — time, personnel, key number all correct;
Local and cloud data consistent, synchronization complete with no data loss.
11.1 Installation and Construction Precautions
Wall Load-Bearing Verification: Before wall-mounted installation, the wall’s load-bearing capacity must be confirmed. Installation on drywall, hollow brick, lightweight partition walls or other walls with insufficient load-bearing capacity is strictly prohibited, to prevent the cabinet from falling, causing damage and personal injury; if installation on a lightweight wall is unavoidable, a reinforced backing plate must be added and secured to the wall’s load-bearing structure.
Proper Drilling Procedures: Before drilling, confirm the distribution of pipes and wires within the wall, avoiding electrical wires, water pipes, gas pipelines, etc., to prevent drilling damage to utilities and safety incidents; wear protective goggles during drilling and take dust prevention measures.
Installation Leveling Calibration: A level must be used to calibrate cabinet levelness. A tilted cabinet will cause issues such as door opening/closing resistance, misalignment of locks, and key slot jamming, affecting normal equipment operation.
Bolt Tightening Requirements: Expansion bolts must be tightened to the proper torque to ensure the cabinet is securely mounted. After installation, a push-pull test must be performed to confirm no looseness; regularly check bolt tightness to prevent loosening over extended use.
Working at Height Safety: When performing elevated installation work, the step ladder must be placed on stable ground, with someone holding the ladder for supervision. Unauthorized high-altitude work is strictly prohibited to prevent falls and injuries.
Finished Product Protection: During installation, protect the cabinet finish to avoid scratches, paint damage, and glass breakage; after installation completes, clean up the work site and clean the cabinet.
11.2 Wiring Operation Precautions
Strict Power-Off Operation: All wiring and maintenance work must be performed with power disconnected. Hot-swapping modules or terminal connections is strictly prohibited, to prevent electric shock, short circuits, and equipment damage.
Wire Sequence and Polarity Verification: Before wiring, confirm positive/negative polarity and communication wire sequence. Reversing DC power polarity will immediately burn out modules; reversing communication lines will cause communication failure. Always verify markings before wiring.
Power/Signal Separation: Power lines and signal lines must be routed separately, with a spacing of ≥20cm, to avoid electromagnetic interference; mixing power and signal wires in the same conduit or on the same terminal block is strictly prohibited.
Secure and Standard Wiring: Strip appropriate lengths of conductor insulation, tighten terminals fully — no loose connections, no poor contact that could cause heating, arcing, or communication interruption; stranded wires must be terminated with ferrules before connecting to terminal blocks. Direct twisting of wires is prohibited.
Reliable Grounding: The equipment’s protective ground wire must be reliably connected. Ungrounded or false grounding is prohibited. Grounding resistance must meet requirements to ensure electrical safety and prevent static damage to chips.
Cable Protection: Leave service loops at cable bends to avoid excessive tension or sharp bends damaging conductors; use grommets when cables pass through metal openings to prevent cutting the insulation; outdoor cable runs must be protected in conduit, with sun and water protection.
No Unauthorized Modifications: Modifying internal equipment wiring or changing module parameters without authorization is strictly prohibited. For any modifications, contact the manufacturer’s technical personnel for guidance. Damage caused by unauthorized modifications is not covered under warranty.
11.3 Daily Operation Precautions
Standard Operating Procedures: Strictly follow the operating instructions for key access and return. Open and close cabinet doors gently. Place keys evenly into slots. Forcibly inserting/removing keys or slamming cabinet doors is strictly prohibited to prevent damage to locks and sensors.
Identity Verification Standards: For facial recognition, face the camera directly, keep the full face within the capture frame, with even lighting; for fingerprint verification, keep fingers clean and dry, place flat on the sensor without sliding; for card swiping, hold the card steadily close to the reading area, without rapid waving.
Screen Touch Standards: Touch the screen with fingers only. Do not use fingernails or hard objects, and do not press or tap the screen forcefully to prevent screen cracking; clean the screen with a soft dry cloth. Using corrosive cleaners such as alcohol or gasoline is prohibited.
Cabinet Contents Management: Only bound keys may be stored inside the cabinet. Storing other items, flammable/explosive materials, or liquids is strictly prohibited to prevent equipment damage and safety hazards; do not hang excessively heavy items on key fobs to prevent damage to slot locks.
Emergency Key Management: The mechanical emergency key must be kept by designated personnel in a safe location, never locked inside the cabinet, and only used in emergency situations. Routine use is strictly prohibited; after emergency key use, log the usage and return it promptly.
Password Security Management: Administrator passwords should be changed regularly, avoiding simple passwords; passwords must be kept by designated personnel and not disclosed; promptly deactivate accounts and permissions when personnel leave.
No Unauthorized Disassembly: Non-professionals are strictly prohibited from disassembling the cabinet or removing modules. For malfunctions, contact the manufacturer’s after-sales service. Damage caused by unauthorized disassembly is not covered under warranty.
11.4 Environmental Safety Precautions
Temperature and Humidity Control: The equipment operating environment must be maintained within the rated temperature and humidity range. Avoid prolonged operation in high-temperature or high-humidity environments to prevent component aging and corrosion; desiccant can be placed in humid environments, and check regularly for condensation.
Dust Prevention and Cleaning: Keep the area around the equipment clean. Regularly clean dust from the cabinet surface and cooling vents to prevent dust from entering the interior, affecting heat dissipation and causing poor contact; increase cleaning frequency in dusty environments.
Keep Away from Interference Sources: Keep equipment away from high-power appliances and strong magnetic devices to prevent electromagnetic interference causing recognition failures and communication faults; avoid direct sunlight on the cabinet to prevent paint fading and screen aging.
Waterproofing and Moisture Protection: Equipment must not come into contact with water. Wiping internal modules with wet cloths is prohibited to prevent short circuits; installation locations must avoid areas with leaks or dripping water, such as under air conditioners or water pipes.
Fire Safety: Do not store flammable or explosive items near the equipment, and keep away from ignition sources; equip the area with fire extinguishing equipment. In case of electrical fire, immediately cut off power and use a dry powder extinguisher. Never use water to extinguish electrical fires.
11.5 Data Security Precautions
Regular Data Backup: Administrators should regularly export and back up operation logs and system configurations. It is recommended to back up monthly to prevent data loss due to equipment failure.
Account Permission Management: Strictly manage accounts by hierarchy, following the principle of least privilege, assigning permissions as needed; promptly deactivate or adjust account permissions when personnel leave or transfer positions to prevent unauthorized operations.
Network Security Protection: When connected to a LAN, implement network security measures, configure firewalls, and prohibit direct exposure to the public internet; regularly update system firmware to patch security vulnerabilities.
Data Confidentiality Requirements: User biometric information, operation records and other data must be kept strictly confidential; disclosure or external transmission is prohibited; implement permission controls on cloud data to prevent data leakage.
System Recovery Notice: Data must be backed up before restoring factory settings — all data will be cleared after restoration; data recovery operations must be performed by the administrator and logged accordingly.
11.6 Transportation and Storage Precautions
Transportation Protection: Equipment must be transported in an upright position. Inverting or laying on the side is prohibited; provide appropriate cushioning during transport to avoid severe vibration and impacts; provide waterproof covering during rainy-weather transport.
Handling Specifications: Lift and lower equipment gently during handling. Dragging or rolling is prohibited; two people should coordinate to carry large cabinets to prevent crushing injuries; grip the cabinet frame when carrying, never the door handles, display screens or other fragile parts.
Storage Environment: Store equipment in a dry, ventilated warehouse free of corrosive gases, with temperature and humidity meeting storage requirements; do not stack heavy items on top of the cabinet to prevent deformation; for long-term storage, power on periodically to prevent component moisture damage.
Original Packaging Retention: Keep the original packaging. When transport or return for factory repair is subsequently needed, use the original packaging for the best protection.
12.1 Daily Maintenance Standards
Daily maintenance is performed by the user’s administrator, on a daily/weekly basis, to ensure stable day-to-day equipment operation:
Daily Inspection Items:
- Check equipment appearance is intact, no damage or abnormalities;
- Check power and network connections are normal, indicator lights display correctly;
- Check touch screen and recognition module surfaces are clean, free of stains and dust;
- Spot-check key presence status against system display;
- Check cabinet doors open/close smoothly, no abnormal noise, no jamming;
- Check system for alarm messages, promptly handle any abnormalities.
Weekly Cleaning and Maintenance:
- Wipe the cabinet surface with a clean soft cloth to remove dust and stains;
- Wipe the display screen, fingerprint sensor, and camera lens with a lint-free soft cloth to keep clean;
- Clear debris around the cabinet to keep the environment tidy;
- Check cooling vents are unobstructed, not blocked by dust.
Daily Maintenance Precautions:
- Perform cleaning with power off to prevent water droplets or cleaners from entering the equipment interior;
- Prohibited from using alcohol, thinner, strong acids or alkalis for cleaning, to prevent corrosion of paint surfaces and plastic parts;
- Be gentle when cleaning the fingerprint sensor and camera to avoid scratching the lens.
12.2 Scheduled Maintenance Plan
To extend equipment service life and ensure stable performance, a scheduled maintenance plan must be established and executed on a periodic basis:
| Maintenance Cycle | Executing Department | Main Maintenance Contents |
|---|---|---|
| Monthly Maintenance | User’s Administrator | Full function check, data backup, exterior cleaning, wiring inspection |
| Quarterly Maintenance | Maintenance Personnel / Manufacturer After-Sales | Internal dust removal, mechanical component lubrication, electrical connection tightening, performance calibration |
| Annual Maintenance | Manufacturer Professional After-Sales Personnel | Comprehensive in-depth inspection, firmware upgrade, wear part replacement, performance optimization |
12.3 Quarterly Maintenance Contents
Quarterly maintenance should be performed by maintenance personnel with certain electrical knowledge, or by contacting the manufacturer for on-site service. Specific contents:
Internal Dust Removal and Cleaning
- After power-off, open the cabinet side cover or rear cover, use a soft brush and vacuum cleaner to clean internal dust, focusing on the mainboard, power supply, and cooling fan areas;
- Clean the RFID antennas and sensor surfaces to ensure recognition sensitivity;
- After cleaning, check that no debris remains and reinstall the cover panels.
Mechanical Component Maintenance
- Apply a small amount of lubricating oil to cabinet door hinges to ensure smooth opening/closing and reduce wear;
- Check door locks and latch bolts, clean stains, apply light lubrication, ensure flexible operation;
- Check all screw fastenings, re-tighten any loose screws;
- Check door seals are intact, free from aging and deformation, with good sealing.
Electrical Connection Inspection
- Check all terminal connections for tightness, re-tighten any loose terminals;
- Check cables for aging, damage, or heat marks; promptly replace problem cables;
- Check grounding connections are reliable, test grounding resistance meets requirements;
- Check the power adapter operates normally, no overheating or abnormal noise.
Function Performance Verification
- Comprehensively test all function modules — recognition accuracy, lock response, alarm functions normal;
- Calibrate system time, verify data accuracy;
- Check hard disk storage capacity, clean redundant data to ensure sufficient storage space.
12.4 Annual Maintenance Contents
Annual maintenance is recommended to be performed on-site by the manufacturer’s professional after-sales engineers for comprehensive in-depth maintenance, with the following contents:
Full Machine In-Depth Inspection
- Disassemble core modules, thoroughly clean dust and oxides;
- Test power supply output voltage and ripple, evaluate power supply health;
- Test mainboard and module operating parameters, evaluate component aging condition;
- Test overall machine performance indicators, compare with factory parameters, evaluate performance degradation.
Wear Parts Inspection and Replacement
- Check electric lock wear — replace those reaching their service life;
- Check fingerprint sensor and camera lens wear — replace those affecting recognition;
- Check UPS battery capacity — recommend replacement when degraded to below 80%;
- Check cooling fans, buttons, indicator lights and other wear parts — replace any that are faulty.
System Upgrade and Optimization
- Upgrade device firmware to the latest version, fix known issues, optimize performance;
- Upgrade management software and cloud platform versions to obtain the latest features;
- Optimize system configuration parameters to suit the application scenario and improve operating efficiency;
- Organize the database, clean redundant data, improve system response speed.
Safety Hazard Inspection
- Comprehensively inspect electrical safety hazards, replace aging cables and terminals;
- Inspect mechanical safety hazards, reinforce loose structures, replace worn components;
- Inspect data security hazards, optimize permission configurations, strengthen network security.
Maintenance Report Issuance
- After maintenance, issue a formal maintenance report documenting maintenance contents, test data, replaced parts, issues and recommendations;
- Provide maintenance recommendations for the next year to guide user routine maintenance.
12.5 Common Component Repair and Replacement Methods
12.5.1 Power Adapter Replacement
Fault Symptom: Equipment has no power, power indicator does not light. After ruling out outlet issues, determine that the adapter is damaged.
Replacement Steps:
1. Disconnect mains power, unplug both ends of the faulty adapter;
2. Replace with a genuine power adapter of the same specification — ensure output voltage and current are identical;
3. Insert both ends of the connector, power on and test that the equipment starts normally.
Precautions: An original adapter of identical specifications must be used. Substitute power supplies with mismatched parameters are prohibited to prevent equipment damage.
12.5.2 Electric Lock Replacement
Fault Symptom: A single slot’s lock cannot unlock, unlocks weakly, or the latch bolt jams. After ruling out driver board issues, determine that the lock is damaged.
Replacement Steps:
1. Cut power, open the cabinet door, remove the decorative panel of the corresponding slot;
2. Unplug the lock’s wiring connector, remove the mounting screws;
3. Remove the old lock, install the new lock, align the position and tighten the screws;
4. Reconnect the wiring connector, reinstall the decorative panel;
5. Power on and test that the lock unlocks and locks normally.
Precautions: The lock model must match; wiring polarity must be correct; installation must be properly seated to avoid latch bolt misalignment.
12.5.3 RFID Tag Replacement
Fault Symptom: Key cannot be recognized, presence detection is abnormal. After ruling out slot antenna issues, determine that the tag is damaged.
Replacement Steps:
1. Cut the stainless steel wire on the old key fob and remove the damaged tag;
2. Enroll the new tag into the system, bind the corresponding key information;
3. Use new stainless steel wire to securely bind the new tag to the key, crimped firmly;
4. Place in the slot for testing — recognition is normal, status updates correctly.
Precautions: After replacement, the binding information must be updated in the system and the old tag data deleted.
12.5.4 Touch Screen Replacement
Fault Symptom: Screen cracked, touch malfunction, display abnormal — determine that the screen is damaged.
Replacement Steps:
1. Cut power, remove the front panel screws, remove the front panel;
2. Unplug the screen’s ribbon cable and power cable, remove the faulty screen;
3. Install the new screen, reconnect the ribbon cable and power cable, ensuring the ribbon cable is fully seated;
4. Secure the screen, reinstall the front panel, power on and test that display and touch operate normally.
Precautions: Handle the ribbon cable gently during insertion/removal to avoid breakage; ensure the screen is seated firmly with no dust entering.
12.6 System Software Maintenance and Upgrade
12.6.1 Routine Software Maintenance
Regularly clean system cache to improve operating speed;
Regularly export backup data to prevent data loss;
Monitor system operating status, promptly handle any abnormalities;
Installing unrelated software and modifying low-level system parameters is prohibited.
12.6.2 Firmware Upgrade Procedure
Pre-Upgrade Preparation:
- Back up all device data and configurations;
- Ensure stable device power supply — UPS power is recommended to prevent power interruption during upgrade causing device failure (“bricking”);
- Obtain the latest firmware package for the corresponding model, confirm version compatibility.
Upgrade Steps:
1. Copy the upgrade package to a USB drive and insert it into the device’s USB port;
2. Go to System Settings → System Upgrade, select the USB upgrade package;
3. Click “Upgrade” — the system automatically verifies the upgrade package and begins upgrading;
4. During the upgrade, do not cut power or operate the device; wait for the system to automatically restart;
5. After restart, check the system version to confirm the upgrade was successful, and test all functions normally.
Precautions:
- If the upgrade fails, retry the upgrade; if the issue persists, contact manufacturer technical support;
- Cross-version upgrades must be performed incrementally; skipping too many versions is not permitted;
- Some configurations may be reset after the upgrade, requiring re-verification of settings.
12.7 Spare Parts Management
To ensure rapid repair in case of failure, users are advised to stock commonly used wear parts:
Recommended Spare Parts List: Power adapter, RFID electronic key fobs, electric locks, fuses, mechanical lock cylinders, emergency keys.
Spare Parts Management Requirements:
- Store spare parts properly, moisture-proof and dust-proof, labeled with model and specification;
- Establish a spare parts ledger, log inbound/outbound, conduct periodic inventory;
- Replenish spare parts promptly after consumption to maintain reasonable stock levels.
Spare Parts Procurement Channel: Purchase original spare parts through Guangzhou Lain official channels to ensure quality and compatibility. Use of third-party inferior spare parts is prohibited.
13.1 Power Supply Faults
| Fault Symptom | Possible Causes | Troubleshooting Steps | Solutions |
|---|---|---|---|
| Equipment completely powered off, screen off, no response | 1. Mains power outage or no power at outlet<br>2. Power adapter damaged<br>3. Power switch not turned on<br>4. Internal fuse blown<br>5. Power cable loose or disconnected | 1. Test outlet for voltage, confirm mains power normal<br>2. Check if device power switch is on<br>3. Replace with same-spec adapter to test<br>4. Check if internal power fuse is blown<br>5. Check if internal power cable has disconnected | 1. Restore mains power, use a working outlet<br>2. Turn on the device power switch<br>3. Replace with original power adapter<br>4. Replace with same-spec fuse<br>5. Re-seat the power cable firmly |
| Equipment frequently restarts or shuts down automatically | 1. Unstable power supply voltage<br>2. Power adapter insufficient wattage<br>3. Internal poor contact<br>4. Poor heat dissipation triggering over-temperature protection<br>5. UPS battery fault | 1. Measure input voltage with multimeter for stability<br>2. Check if adapter specifications match<br>3. Check if internal terminals are loose<br>4. Check if cooling vents are blocked, equipment overheating<br>5. Test by disconnecting UPS | 1. Install voltage regulator to stabilize power<br>2. Replace with original adapter<br>3. Tighten loose terminals<br>4. Clean dust, improve ventilation and cooling<br>5. Repair or replace UPS battery |
| UPS does not supply power after power outage | 1. UPS battery not charged<br>2. UPS switch not turned on<br>3. Battery damaged/failed<br>4. UPS wiring loose | 1. Check if UPS switch is on<br>2. Charge from mains for 8 hours, then test<br>3. Measure battery voltage, determine failure<br>4. Check UPS connections are secure | 1. Turn on UPS switch<br>2. Test after full charge<br>3. Replace UPS battery pack<br>4. Re-tighten connections |
| Equipment casing feels tingly, strong induced current | 1. Protective ground not connected<br>2. Poor grounding<br>3. Live and neutral wires reversed | 1. Check if ground wire is connected<br>2. Test grounding resistance for compliance<br>3. Measure if live/neutral are reversed | 1. Reliably connect protective ground<br>2. Rectify grounding, reduce grounding resistance<br>3. Correct the live/neutral wiring |
13.2 Identity Recognition Faults
| Fault Symptom | Possible Causes | Troubleshooting Steps | Solutions |
|---|---|---|---|
| Facial recognition fails, recognition error | 1. Face not enrolled in system<br>2. Incorrect positioning, face not fully in frame<br>3. Lighting too bright or too dark<br>4. Camera lens dirty<br>5. Facial features significantly changed (mask, hat, glasses)<br>6. Camera malfunction | 1. Confirm user’s face is enrolled in system<br>2. Adjust positioning, face camera directly, full face in frame<br>3. Improve ambient lighting, avoid backlighting/strong light<br>4. Clean camera lens<br>5. Remove mask/hat; try enrolling a template with glasses if worn<br>6. Check if camera image is normal | 1. Re-enroll face data<br>2. Standardize operating posture<br>3. Adjust ambient lighting<br>4. Clean the lens<br>5. Enroll multiple templates<br>6. Replace camera module |
| Fingerprint recognition success rate low, frequent failures | 1. Fingerprint not enrolled or poor enrollment quality<br>2. Fingers dry, wet, or dirty<br>3. Fingerprint sensor surface dirty or scratched<br>4. Incorrect pressing method, insufficient pressure<br>5. Fingerprints heavily worn, few feature points | 1. Check enrollment quality, re-enroll<br>2. Clean and dry fingers before trying again<br>3. Clean sensor surface; replace if heavily scratched<br>4. Press finger flat on sensor with moderate pressure<br>5. Recommend using other verification method | 1. Re-enroll high-quality fingerprints, enroll multiple fingers<br>2. Keep fingers clean and dry<br>3. Clean or replace fingerprint sensor<br>4. Standardize pressing operation |
| Card swipe no response, cannot be recognized | 1. Card not authorized/enrolled<br>2. Card type incompatible<br>3. Reading distance too far<br>4. Card reader module fault<br>5. Card demagnetized/damaged | 1. Confirm card is enrolled in system<br>2. Confirm card is ISO14443A standard IC card<br>3. Hold card close to reading area<br>4. Test with a test card to determine module fault<br>5. Test with another card | 1. Enroll card authorization<br>2. Use compatible card type<br>3. Standardize card swipe operation<br>4. Repair/replace card reader module<br>5. Replace with new card and re-enroll |
| Password verification error | 1. Password entered incorrectly<br>2. Password forgotten<br>3. Keyboard/touch drift<br>4. Account locked | 1. Carefully verify password, re-enter<br>2. Have administrator reset password<br>3. Calibrate touch screen<br>4. Wait for lockout period to end or have administrator unlock | 1. Enter password correctly<br>2. Administrator resets user password<br>3. Perform screen touch calibration<br>4. Unlock the account |
13.3 Lock and Cabinet Door Faults
| Fault Symptom | Possible Causes | Troubleshooting Steps | Solutions |
|---|---|---|---|
| Cabinet door cannot open, no response after verification | 1. Identity verification failed<br>2. Electric lock fault<br>3. Lock control board fault<br>4. Cabinet door deformed/jammed<br>5. Mechanical lock seized | 1. Confirm verification passed, with door open prompt<br>2. Listen for lock activation sound<br>3. Test lock operation in test mode<br>4. Check if door is deformed or misaligned<br>5. Try opening with mechanical emergency key | 1. Complete identity verification correctly<br>2. Replace the corresponding electric lock<br>3. Repair/replace lock control board<br>4. Adjust door hinges, correct door alignment<br>5. Repair mechanical lock cylinder |
| Key cannot be removed from a single slot | 1. Not authorized for unlock, latch not retracted<br>2. Electric lock fault, latch not moving<br>3. Key fob tilted/jammed<br>4. Latch and lock hole misaligned | 1. Confirm key is authorized and in unlocked state<br>2. Trigger unlock in test mode, listen for latch sound<br>3. Gently wiggle key fob, attempt removal<br>4. Check slot installation alignment | 1. Complete authorized unlock before removal<br>2. Replace faulty electric lock<br>3. Straighten key fob and remove<br>4. Adjust slot position, align latch |
| Cabinet door does not close tightly, large gap | 1. Cabinet installed tilted<br>2. Door hinges loose or shifted<br>3. Door seal deformed or detached<br>4. Door lock catch position offset | 1. Check cabinet levelness and plumb<br>2. Check hinge screws for looseness<br>3. Check door seal integrity<br>4. Adjust lock catch position | 1. Adjust cabinet to level and plumb<br>2. Tighten hinge screws, adjust door position<br>3. Replace or reattach door seal<br>4. Adjust lock catch position for tight closure |
| Cabinet door makes abnormal noise or jams during open/close | 1. Hinges dry/lacking lubrication and worn<br>2. Door deformed, rubbing against cabinet<br>3. Foreign object jamming<br>4. Hinge screws loose | 1. Check hinges for rust or lack of lubrication<br>2. Check door gap uniformity, rubbing spots<br>3. Clean debris from door gaps<br>4. Check hinge screw tightness | 1. Apply lubricating oil to hinges<br>2. Adjust and correct door alignment<br>3. Remove debris<br>4. Tighten loose screws |
13.4 Key Identification and Detection Faults
| Fault Phenomenon | Possible Causes | Troubleshooting Steps | Solution |
|---|---|---|---|
| System does not display key presence after insertion | 1. Key not fully inserted<br>2. RFID tag damaged<br>3. Slot antenna fault<br>4. Reader/writer fault<br>5. Tag not bound to system | 1. Re-insert key fob, confirm it clicks into place<br>2. Test in another slot to determine if it is a tag issue<br>3. Test the slot with a known good key to determine if slot is faulty<br>4. Check if the tag is registered and bound in the system<br>5. Check if the reader/writer wiring is loose | 1. Place key correctly and fully seated<br>2. Replace RFID key fob and rebind<br>3. Repair or replace slot antenna module<br>4. Register tag and bind to slot<br>5. Reconnect reader/writer wiring |
| Key presence status flickers or is intermittent | 1. Key fob not stable, poor contact<br>2. Weak tag signal<br>3. Loose antenna cable<br>4. Electromagnetic interference nearby<br>5. Sensor fault | 1. Reposition key and observe stability<br>2. Adjust read/write power to enhance signal<br>3. Check antenna wiring security<br>4. Remove strong electromagnetic devices nearby<br>5. Replace detection sensor | 1. Place key firmly and lock into position<br>2. Adjust read/write power parameters<br>3. Tighten antenna wiring<br>4. Move away from electromagnetic interference sources<br>5. Replace faulty sensor |
| No alarm when key is placed in wrong slot | 1. Misplacement alarm feature not enabled</br>2. Tag cross-talk reading<br>3. Alarm volume set to 0<br>4. Buzzer fault | 1. Check system settings, enable misplacement alarm<br>2. Adjust antenna power to reduce cross-talk probability<br>3. Increase system volume<br>4. Test if buzzer works properly | 1. Enable misplacement alarm feature<br>2. Optimize antenna power settings<br>3. Adjust system volume<br>4. Replace buzzer |
| Inventory count does not match actual | 1. A slot detection fault, missed reading<br>2. Tag damaged, cannot be recognized<br>3. Key placed in wrong slot, not counted<br>4. System data not refreshed | 1. Check slots one by one to find abnormal detection slot<br>2. Check unreadable keys, replace tags<br>3. Check all keys are in corresponding slots<br>4. Refresh system page, re-inventory | 1. Repair faulty detection slot<br>2. Replace damaged tag<br>3. Return keys to correct slots<br>4. Refresh system, re-inventory |
13.5 Network Communication Faults
| Fault Phenomenon | Possible Causes | Troubleshooting Steps | Solution |
|---|---|---|---|
| Wired network connection fails, network port light not lit | 1. Network cable fault<br>2. Switch/router port fault<br>3. Poor contact at network port<br>4. Incorrect device network settings<br>5. Network card hardware fault | 1. Test cable continuity with a cable tester<br>2. Try a different switch port or test port with another device<br>3. Replug cable, check if RJ45 connector is oxidized<br>4. Check network parameter settings, IP conflict<br>5. After excluding above, determine network card fault | 1. Replace with a good network cable<br>2. Switch to a normal switch port<br>3. Re-terminate RJ45 connector, plug cable firmly<br>4. Modify network parameters, set correct IP<br>5. Repair or replace network card module |
| Network intermittent, unstable | 1. Poor network cable contact<br>2. Network loop, IP conflict<br>3. Switch fault<br>4. Severe electromagnetic interference<br>5. Cable length too long, signal attenuation | 1. Check contact between RJ45 and port, replug<br>2. Check for IP conflicts, network loops<br>3. Test by changing switch port<br>4. Check for strong electromagnetic sources nearby<br>5. Measure cable length, ensure not over 100 meters | 1. Re-terminate RJ45, ensure secure connection<br>2. Troubleshoot and resolve IP conflicts, network loops<br>3. Replace switch<br>4. Move away from interference, route cable through shielded metal conduit<br>5. Add relay device or shorten distance |
| Cannot connect via Wi-Fi | 1. Incorrect Wi-Fi password<br>2. Signal too weak<br>3. Router settings restriction<br>4. Wi-Fi module fault<br>5. Frequency band incompatibility (only supports 2.4G) | 1. Verify password, re-enter<br>2. Move closer to router, check signal strength<br>3. Check router MAC address filter, rate limit settings<br>4. Confirm router 2.4G band is enabled<br>5. After excluding above, determine module fault | 1. Enter correct Wi-Fi password<br>2. Adjust antenna, move closer to router, increase signal</br>3. Disable router restrictions, allow device access<br>4. Enable router 2.4G band<br>5. Replace Wi-Fi module |
| Cloud platform shows device offline | 1. Device local network not working<br>2. Incorrect cloud server address setting<br>3. Firewall blocks port<br>4. Device not reconnecting after network disconnection<br>5. Cloud device account abnormal | 1. First check if local network is normal and can access the internet<br>2. Check cloud server address, port settings<br>3. Check if network firewall allows corresponding ports<br>4. Restart device to test reconnection<br>5. Contact manufacturer to check cloud account status | 1. Repair local network fault<br>2. Set correct server parameters<br>3. Open corresponding network ports<br>4. Restart device to reconnect<br>5. Contact technical support to troubleshoot cloud issue |
| Main and sub-cabinet communication failure | 1. Cascade cable disconnected, loose<br>2. Wiring sequence reversed (A/B reversed)<br>3. Duplicate address codes<br>4. Termination resistor not connected<br>5. Cascade distance too long | 1. Check cascade cable connection, replug firmly<br>2. Verify A, B wiring sequence, connect correctly<br>3. Check sub-cabinet address DIP switches, ensure unique<br>4. Add 120Ω termination resistor at bus end<br>5. Keep cascade distance within 1000 meters, add repeater if longer | 1. Tighten cascade cable connection<br>2. Correct wiring sequence<br>3. Set unique address code<br>4. Install termination resistor<br>5. Add 485 repeater |
13.6 Software System Faults
| Fault Phenomenon | Possible Causes | Troubleshooting Steps | Solution |
|---|---|---|---|
| System laggy, slow response | 1. Insufficient storage space</br>2. Too many running programs<br>3. System not restarted for long time<br>4. Excessive data volume<br>5. Hardware performance fault | 1. Check remaining storage capacity<br>2. Close irrelevant background programs<br>3. Restart device to test<br>4. Export historical data, clean redundant records<br>5. After excluding software issues, check hardware | 1. Clean storage, delete useless data<br>2. Restart device to free memory<br>3. Restart device regularly, recommend weekly restart<br>4. Archive historical data regularly<br>5. Upgrade hardware configuration or repair |
| Touchscreen unresponsive, no reaction to clicks | 1. Screen surface has water, stains<br>2. System frozen, lagging<br>3. Touch cable loose<br>4. Touchscreen damaged<br>5. Touch driver abnormal | 1. Wipe and clean screen surface<br>2. Restart device to test<br>3. Power off, reinsert touch cable<br>4. Calibrate touchscreen<br>5. If above ineffective, determine screen damaged | 1. Clean and dry screen<br>2. Restart system<br>3. Replug and tighten cable<br>4. Enter settings to perform touch calibration<br>5. Replace touchscreen |
| Operation records lost, not displayed | 1. System time error<br>2. Incorrect query conditions<br>3. Data storage full, overwriting old data<br>4. System fault data loss<br>5. Insufficient account permissions, cannot see records | 1. Calibrate system time and date<br>2. Adjust query conditions, expand time range<br>3. Check storage capacity, confirm if cyclic overwriting<br>4. Check backup data, recover data<br>5. Test with administrator account | 1. Calibrate system time<br>2. Set correct query conditions<br>3. Backup and export regularly, expand storage<br>4. Restore from backup<br>5. Use account with appropriate permissions |
| Management terminal cannot connect to device | 1. Computer and device not on same LAN<br>2. Device IP changed<br>3. Firewall blocking<br>4. Software version mismatch<br>5. Device network fault | 1. Check network connectivity between computer and device, ping test<br>2. Check device current IP, re-add<br>3. Disable computer firewall, antivirus software to test<br>4. Confirm software version matches device firmware<br>5. Troubleshoot device network issue | 1. Adjust network, ensure same network connectivity<br>2. Update device IP, reconnect<br>3. Allow software through firewall<br>4. Install matching version of management software<br>5. Repair device network |
| System crash, black screen | 1. Power fault<br>2. System crash<br>3. Hardware fault<br>4. Overheating, thermal protection | 1. Check power indicator, rule out power supply issue<br>2. Press reset button to restart, check if it can start normally<br>3. Check if device is overheating, ventilation clear<br>4. If problem recurs after restart, determine hardware fault | 1. Repair power supply fault<br>2. Reset and restart system<br>3. Improve heat dissipation, clean dust<br>4. Contact after-sales for hardware repair |
13.7 Alarm Function Faults
| Fault Phenomenon | Possible Causes | Troubleshooting Steps | Solution |
|---|---|---|---|
| No alarm for abnormal situations | 1. Corresponding alarm feature not enabled<br>2. Alarm volume set to mute<br>3. Sensor sensitivity too low<br>4. Buzzer, warning light damaged<br>5. Alarm condition threshold set too high | 1. Enter system settings, check if corresponding alarm switch is on<br>2. Increase system volume and alarm volume<br>3. Adjust sensor sensitivity parameters<br>4. Trigger alarm in test mode, see if sound and light work<br>5. Adjust alarm threshold, lower trigger conditions | 1. Enable corresponding alarm feature<br>2. Increase alarm volume<br>3. Increase sensor sensitivity<br>4. Replace damaged buzzer/warning light<br>5. Set alarm threshold reasonably |
| Frequent false alarms | 1. Sensor sensitivity too high<br>2. Environmental interference (vibration, airflow, temperature changes)<br>3. Door magnet misalignment<br>4. Unreasonable system parameter settings | 1. Lower corresponding sensor sensitivity</br>2. Identify environmental interference sources, take protective measures<br>3. Adjust door magnet position, ensure accurate alignment<br>4. Optimize alarm parameter settings, extend delay time | 1. Reduce sensor sensitivity<br>2. Eliminate environmental interference, install device firmly<br>3. Adjust door magnet installation position<br>4. Optimize alarm delay and threshold parameters |
| Alarm notifications not pushed | 1. Device network disconnected<br>2. Push feature not enabled<br>3. Administrator account not bound for push<br>4. Mobile app notifications disabled<br>5. Cloud push service abnormal | 1. Check if device network is connected<br>2. Enable alarm push in system settings<br>3. Configure push receiving permissions for administrator account<br>4. Check if mobile app/WeChat notification permission is enabled<br>5. Contact manufacturer to check cloud push service | 1. Restore device network connection<br>2. Enable alarm push feature</br>3. Configure administrator push permissions<br>4. Enable mobile notification permissions<br>5. Contact technical support for troubleshooting |
13.8 Other Comprehensive Faults
| Fault Phenomenon | Possible Causes | Troubleshooting Steps | Solution |
|---|---|---|---|
| Device time incorrect | 1. Network time synchronization not enabled<br>2. Internal RTC battery dead<br>3. Time zone setting error<br>4. Long power outage | 1. Enable network time sync, connect to network for auto calibration<br>2. If time resets to zero after power off, determine RTC battery failure<br>3. Check if time zone is set to East 8 (+8:00)<br>4. Recalibrate time | 1. Enable NTP network time sync<br>2. Replace motherboard RTC coin battery<br>3. Set correct time zone<br>4. Manually calibrate time |
| Device time incorrect | 1. Network time synchronization not enabled<br>2. Internal RTC battery dead<br>3. Time zone setting error<br>4. Long power outage | 1. Enable network time sync, connect to network for auto calibration<br>2. If time resets to zero after power off, determine RTC battery failure<br>3. Check if time zone is set to East 8 (+8:00)<br>4. Recalibrate time | 1. Enable NTP network time sync<br>2. Replace motherboard RTC coin battery<br>3. Set correct time zone<br>4. Manually calibrate time |
| No sound or prompt tone from voice broadcast | 1. System volume set to 0 or muted<br>2. Speaker wiring loose or disconnected<br>3. Speaker hardware damaged<br>4. Voice broadcast function disabled in system | 1. Enter system settings, check volume, increase volume<br>2. Power off, check speaker wiring is properly connected<br>3. Trigger broadcast in test mode, listen for any electrical noise<br>4. Check if voice broadcast feature switch is on | 1. Increase system volume, disable mute mode<br>2. Replug speaker wiring terminal<br>3. Replace built-in speaker module<br>4. Enable system voice broadcast feature |
| Voice broadcast distorted, poor sound quality | 1. Speaker damaged by water or dust<br>2. Amplifier circuit fault<br>3. Power supply ripple interference<br>4. Volume maxed out, overload | 1. Check speaker hole for dust, water stains<br>2. Lower volume and test if distortion persists<br>3. Replace power adapter to test if it is power interference<br>4. Check for electromagnetic interference sources nearby | 1. Clean speaker hole, dry, replace if damaged<br>2. Repair or replace amplifier circuit module<br>3. Replace with original power adapter<br>4. Appropriately reduce volume to avoid overload |
| Optional thermal printer does not print | 1. Printer not powered, wiring loose<br>2. Paper roll finished<br>3. Paper compartment cover not closed properly<br>4. Print head damaged or dirty<br>5. Printing function not enabled in system | 1. Check printer power and data connections<br>2. Open paper compartment, check for paper<br>3. Re-close paper compartment cover, confirm it latches<br>4. Clean print head, check for burn marks<br>5. Enable receipt printing in system settings | 1. Tighten printer connections, restore power<br>2. Replace with same specification thermal paper<br>3. Close paper compartment cover properly<br>4. Clean print head with alcohol swab, replace if damaged<br>5. Enable system auto-print function |
| Printer prints blurred, missing lines | 1. Print head surface dirty<br>2. Print paper quality poor or expired<br>3. Insufficient print pressure<br>4. Print head worn out, damaged | 1. Power off, wipe print head surface with alcohol swab<br>2. Replace with original good quality thermal paper<br>3. Adjust paper compartment pressure mechanism, increase contact<br>4. Replace with new print head | 1. Clean print head regularly, keep clean<br>2. Replace with quality thermal paper<br>3. Adjust print pressure mechanism<br>4. Replace print head assembly |
| No image from operation snapshot camera | 1. Camera wiring loose<br>2. Camera power supply abnormal<br>3. Camera lens blocked</br>4. Camera module damaged<br>5. Snapshot function not enabled in system | 1. Power off, replug camera cable<br>2. Check camera supply voltage is normal<br>3. Check lens for dust, obstruction<br>4. Replace test camera, determine hardware fault<br>5. Enable operation snapshot in system settings | 1. Reconnect camera cable firmly<br>2. Repair power supply, restore normal voltage<br>3. Clean lens, remove obstruction<br>4. Replace HD camera module<br>5. Enable snapshot and recording functions |
| USB drive not recognized | 1. USB drive format incompatible<br>2. USB drive capacity too large, not supported<br>3. USB port loose or damaged<br>4. USB drive itself faulty<br>5. USB feature disabled in system | 1. Confirm USB drive is FAT32 format, reformat and retry<br>2. Try smaller capacity USB drive (within 32GB)<br>3. Test with another USB port, determine port fault<br>4. Test with a known good USB drive, rule out drive issue<br>5. Check system settings, enable USB peripheral permission | 1. Format USB drive to FAT32 format<br>2. Use reputable brand USB drive with capacity 32GB or less<br>3. Repair or replace USB port<br>4. Replace with a functional USB drive<br>5. Enable system USB peripheral permission |
| Device has abnormal noise, odor | 1. Cooling fan fault, bearing wear<br>2. Power supply overload, overheating noise<br>3. Internal screws loose, vibration noise<br>4. Component overheating, burning, causing odor | 1. Listen for noise source, locate fan area<br>2. Check power supply temperature and output current<br>3. Power off, check if internal screws are loose<br>4. Immediately power off, check for burn marks inside | 1. Replace cooling fan, add lubricating oil<br>2. Check load, replace faulty power supply<br>3. Tighten all loose screws<br>4. Power off, stop operation, contact after-sales for repair, do not force power on |
13.8.1 General Troubleshooting Principles
When a device fault occurs, it is recommended to follow the general troubleshooting principles of “software first, then hardware; external first, then internal; common issues first, then individual ones” to efficiently locate problems and reduce unnecessary disassembly and mis-operation:
- Software first, then hardware: Prioritize checking software-level issues such as system settings, parameter configuration, network settings. Exclude software faults by restarting the device, restoring default configuration, upgrading firmware, etc., before checking hardware issues, avoiding blind disassembly that could expand the fault range.
- External first, then internal: First check external factors such as power supply, network connections, peripheral compatibility, environmental interference. After ruling out external issues, then disassemble to inspect internal components, minimizing unnecessary disassembly impact on device sealing and structure.
- Common issues first, then individual ones: If multiple functions fail simultaneously, prioritize checking common parts, such as main power, main control board, communication bus. If a single slot or module fails, prioritize checking the corresponding branch components and wiring.
- Power off before operation: All hardware troubleshooting, wiring, and disassembly operations must be performed with power off to prevent electric shock and secondary component damage. Only software settings, external USB drive plugging/unplugging, and other low-voltage operations may be performed with power on.
- Do not disassemble blindly: Non-professionals are prohibited from disassembling core control modules. If a fault cannot be resolved by yourself, contact manufacturer technical support promptly and preserve the fault site for remote diagnosis. Damage caused by unauthorized disassembly is not covered by warranty.
Chapter 14: Product QA (Frequently Asked Questions)
This chapter summarizes high-frequency user questions throughout the entire lifecycle of the smart key cabinet, categorized by application scenario, providing quick reference for end users, administrators, and maintenance personnel. It also serves as standardized material for internal training and pre-sales consultation.
14.1 Basic Knowledge Questions
Q1: What exactly is a smart key cabinet? What is the essential difference from an ordinary steel key cabinet?
A: A smart key cabinet is a kind of intelligent management and control device integrating RFID radio frequency identification, biometric recognition, embedded industrial control, and IoT cloud platform technology. The core difference from ordinary key cabinets lies in the control dimension: ordinary key cabinets only solve the “physical storage” problem, essentially a steel cabinet with mechanical locks. Key retrieval relies entirely on manual registration and dedicated personnel, with ambiguous rights and responsibilities and no traceability. Smart key cabinets solve the “full-process closed-loop control” problem, automatically verifying personnel identity, precisely controlling retrieval permissions for each key, automatically retaining all operation logs, and providing real-time alarms for abnormal events. They digitize physical keys, realizing unmanned, digitalized, and traceable key management, upgrading from simple physical protection to a full-process safety control system.
Q2: Must the smart key cabinet be connected to the network? Is it completely unusable without network?
A: No, network connection is not mandatory. All Guangdong Lain smart key cabinets support offline independent operation mode. All identity verification, key access, and log storage functions can be completed locally on the terminal. Operation data is automatically cached to the local storage unit, fully supporting daily use. The core purpose of networking is to enable remote management, centralized control of multiple devices, remote alarm notification, cloud data backup, and other value-added functions. Users can choose whether to connect to the network based on their management needs. After network recovery, locally cached data is automatically uploaded to the server via breakpoint resume, ensuring no operation records are lost.
Q3: What is the maximum number of keys a single smart key cabinet can manage? What if the key quantity is insufficient?
A: A single standard floor-standing smart key cabinet supports up to 150 independent key slots, managing 150 physical keys. Wall-mounted models support up to 60 slots. If single cabinet capacity is insufficient, main cabinet + sub-cabinet cascade expansion is supported. One main cabinet can cascade up to 255 sub-cabinets, theoretically allowing unlimited key capacity expansion, suitable for large enterprises, parks, factories, and other high-volume key management scenarios. After cascading, all keys are uniformly authorized and recorded in the same management system, providing an operation experience identical to a single cabinet.
Q4: Can the RFID key fob be privately removed and swapped to another key?
A: No. The RFID electronic key fobs provided by Guangdong Lain use a one-time stainless steel wire crimping binding process. Once crimped, they cannot be removed without damage. If the wire is forcibly cut, the tag cannot be re-crimped for reuse. To rebind to a different key, an administrator must re-register and re-bind it in the system. The core purpose of this design is to prevent unauthorized key swapping and replacement, ensuring each key has a unique electronic identity and traceable responsibility, providing physical-level control security.
Q5: What identity verification methods does the smart key cabinet support? Can we use only card swiping as the sole method?
A: Guangdong Lain smart key cabinets come standard with four basic verification methods: face recognition, fingerprint recognition, IC card recognition, and digital password. Optional high-level biometric modules such as finger vein recognition and iris recognition are also available. Users can flexibly configure verification rules based on their security level needs: either single verification mode (e.g., card only) or multi-factor combination verification such as “face + password” or “card + fingerprint”, balancing security level and convenience as needed.
14.2 Installation and Deployment Questions
Q1: What are the wall requirements for wall-mounted smart key cabinets? Can they be installed on drywall partitions?
A: Wall-mounted installation requires load-bearing walls such as solid brick walls or concrete walls, with single-point load-bearing capacity of no less than 50kg. Walls with insufficient load-bearing capacity, such as drywall, hollow brick walls, or lightweight partitions, cannot be directly wall-mounted. Forced installation risks cabinet falling, equipment damage, and personal injury. If installation on lightweight walls is necessary, a reinforcement plan must be customized, such as adding a through-wall load-bearing backplate or fixing to the wall’s internal stud load-bearing structure. Installation is only permissible after load-bearing calculation meets requirements.
Q2: How much space needs to be reserved for installing a smart key cabinet? What are the power socket requirements?
A: Space reservation requirements: at least 80cm of operation space in front of the cabinet is required to ensure the door can fully open and personnel can operate smoothly. Reserve more than 50mm heat dissipation space on each side of the cabinet. Reserve more than 30mm wiring space at the back. Power requirements: a standard 10A three-hole mains socket is sufficient. Standby power consumption is less than 30W, peak power does not exceed 80W, easily supported by ordinary residential sockets. It is recommended to place the socket on the side or bottom of the cabinet to avoid exposed wiring affecting appearance. Preferably connect to a dedicated circuit, avoiding sharing with high-power motors, frequency converters, and other equipment to prevent voltage fluctuations interfering with device operation.
Q3: Can the smart key cabinet be used directly outdoors? Is it rainproof and sunproof?
A: Standard smart key cabinets are designed for indoor use with protection rating IP30. They are not waterproof or sun-proof and cannot be placed directly in outdoor open environments. For outdoor use, industrial outdoor models can be customized: sealed waterproof structure, sun and rain shield, electronic components treated with three-proof (moisture-proof, mold-proof, salt-spray-proof) processes, suitable for complex environments such as outdoor open areas, underground pipe corridors, and field stations. For semi-outdoor scenarios (e.g., kiosks with rain shelters, corridors), enhanced sealed models are available. Specific requirements can be assessed by contacting manufacturer technical personnel.
Q4: How long does it take to install a smart key cabinet? Is the installation process complicated?
A: For a single standard smart key cabinet, installation and wiring by professional installers takes approximately 30-60 minutes for wall-mounted models and 15-30 minutes for floor-standing models. Including system debugging, key binding, and personnel training, delivery can be completed within half a day. The installation process is highly standardized, only requiring cabinet fixing and power/network connection. No complex civil engineering is needed, and the existing decoration is not damaged. For multi-cabinet cascade or third-party system integration scenarios, the project timeline extends based on equipment quantity and integration complexity, generally 1-3 days.
Q5: Can the equipment be moved after installation? Is moving it troublesome?
A: Yes, it can be moved. Wall-mounted models require powering off, disconnecting cables, removing expansion bolts, then drilling new holes and reinstalling at the new location. Floor-standing models are simpler: after power off and cable disconnection, they can be pushed directly to the new location, level the feet, connect power and network, and they are ready for use. For short-distance small adjustments, floor-standing models can be pushed directly without disassembly. It is recommended to plan the optimal location before installation to minimize frequent movement, avoiding vibration that could affect internal component precision and structural fastening.
14.3 Operation and Usage Questions
Q1: Do ordinary employees need special training for the first use of the smart key cabinet? Is it easy to learn?
A: Ordinary users do not require professional training. The device features a 10.1-inch touchscreen graphical interface with operation logic consistent with smartphones. Both key retrieval and return include step-by-step text and voice prompts, along with slot indicator light guidance. Regular users can operate independently after one demonstration, with zero learning curve. Administrator operations are relatively more complex; we provide 1-2 hours of specialized training. Generally, administrative, logistics, and security personnel can quickly master basic management functions.
Q2: What if a key is lost? Are there safety risks?
A: In the event of a lost key, the administrator should immediately deregister the corresponding key tag in the system. The tag becomes invalid immediately and can no longer be used to return the key through the system. Simultaneously, the system can quickly query the last user’s information, establishing a clear chain of responsibility. For the physical key loss, it is recommended to change the corresponding lock cylinder promptly based on importance to prevent physical security risks. Compared to traditional key cabinets where losses are untraceable and responsibilities unclear, smart key cabinets can precisely locate responsible individuals, significantly reducing management risks and investigation costs.
Q3: What if there is a sudden power outage at night and keys cannot be retrieved? Is there an emergency plan?
A: A triple emergency plan is provided, completely eliminating concerns about inability to retrieve keys during power outages:
- UPS backup power supply: An optional built-in lithium battery UPS seamlessly switches power supply after mains outage, providing over 8 hours of standby, during which all functions operate normally.
- Mechanical emergency key: Each device comes standard with 2 mechanical emergency keys. During power outage, the cabinet door can be opened via the mechanical lock cylinder to retrieve keys. Emergency keys are stored in a dedicated cabinet managed by a designated person and must not be locked inside the cabinet.
- External emergency power: A hidden Type-C emergency power interface is located at the bottom of the cabinet. Any ordinary power bank can be used to temporarily power on the device for emergency key retrieval.
Q4: Can we use our existing access control badges? Or must we issue new cards?
A: In most scenarios, existing badges are compatible. The device comes standard with a 13.56MHz high-frequency card reading module supporting ISO14443A standard M1 cards and CPU cards. Most domestic access control cards and employee badges from various organizations meet this standard; simply input the card number and it works, achieving a unified card system. For special card types such as ID cards, encrypted CPU cards, or national cryptography cards, please inform us in advance. We can customize card reading modules compatible with those card types.
Q5: How can temporary visitors and outsourced construction personnel use keys in a way that is both convenient and safe?
A: Two mature temporary authorization solutions are available, with full traceability throughout:
- Administrator temporary authorization: The administrator grants visitors permission to use designated keys on the management terminal, sets a validity period, and permissions are automatically revoked upon expiration. Visitors can retrieve keys using temporary cards, verification codes, or temporary face registration.
- Online approval application: Visitors or contact persons submit borrowing requests through a mini-program or management terminal, specifying reason and duration. After the approver approves remotely, the visitor can verify on-site and retrieve the key. Permissions are automatically invalidated after return.
Both solutions eliminate manual handover of physical keys, and all operations are recorded, balancing convenience and security.
14.4 Maintenance and Care Questions
Q1: What is the normal service life of a smart key cabinet?
A: Under proper usage and regular maintenance, the sheet metal mechanical structure of the cabinet can last more than 10 years. Electronic core modules have a service life of 5-8 years. Wear parts such as locks and recognition heads can be replaced individually. The product uses industrial-grade components and a thickened cold-rolled steel cabinet, capable of stable use for 8-10 years in normal office environments, far exceeding ordinary office furniture lifespan. After reaching end-of-life, service life can be extended through module upgrades and wear part replacement without needing to replace the entire cabinet.
Q2: How is daily maintenance performed? Is a dedicated maintenance staff required?
A: Daily maintenance is very simple and does not require dedicated personnel; ordinary administrators can handle it: wipe surface dust regularly with a dry soft cloth to keep the cabinet clean; check device operation status and key presence status once a week; export and backup operation data once a month. For deep maintenance, it is recommended to perform internal dust cleaning and wiring tightening quarterly, and have a factory professional engineer conduct a comprehensive inspection and firmware upgrade annually. Overall maintenance cost is extremely low, with no need for a dedicated position.
Q3: What is the warranty period? What happens after the warranty expires?
A: Guangdong Lain smart key cabinets have a 1-year free warranty for the entire unit, with a 2-year warranty for the core main control motherboard module. Faults not caused by human damage during the warranty period are repaired on-site free of charge and accessories are replaced. After warranty expiration, options include signing an annual maintenance agreement, enjoying regular on-site maintenance, priority on-site response, accessory discounts, and other services. Alternatively, single repairs are available, charging only reasonable accessory costs and on-site service fees, with free lifetime technical consultation support.
Q4: Is system upgrade troublesome? Will the upgrade lose data?
A: System upgrade is simple, supporting both USB local upgrade and remote online upgrade, typically completed within 10 minutes. Before upgrading, the system automatically backs up all data. Normal upgrades will not lose any user data or operation records, ensuring safety and reliability. It is recommended that administrators manually export important data once for double backup before upgrading. Upgrades will fix known issues, optimize performance, and add new features. It is recommended to upgrade regularly to the latest stable version.
Q5: Can we purchase key fobs separately? Are they expensive?
A: Yes, they can be purchased separately. RFID electronic key fobs are common consumables with low cost. You can contact the manufacturer for bulk procurement at any time. It is recommended to purchase original key fobs to ensure recognition stability, service life, and system compatibility. Third-party low-quality tags may result in low recognition rates, short lifespan, cross-talk, and other issues. Key fobs are consumable materials, not covered by warranty. Lost or human-damaged fobs need to be procured separately.
14.5 Safety and Compliance Questions
Q1: With facial and fingerprint biometric information recorded, will privacy be leaked? Is data security guaranteed?
A: We strictly comply with the requirements of the Personal Information Protection Law and the Data Security Law, building a multi-layer data security protection system:
- Irreversible encrypted storage: Biometric features store only encrypted feature templates, not original face or fingerprint images. Even if data is leaked, personal biometric information cannot be reconstructed.
- Encrypted transmission: All data transmission uses AES-256 encryption algorithm, preventing network hijacking and data theft.
- Optional local deployment: Private local deployment is supported; all data is stored on the user’s own servers, not uploaded to public cloud, giving users complete data control.
- Permission control: Multi-level administrator permissions; ordinary personnel cannot access sensitive data; all data operations are logged, preventing internal leaks.
This fully meets the data security and privacy protection requirements of government, enterprise, and classified units.
Q2: Do smart key cabinets meet the management requirements of classified units? Can they pass security acceptance?
A: High-security smart key cabinets fully comply with key management regulations for classified premises. They support dual-person dual-lock verification, multi-level approval, non-tamperable operation logs, private deployment, and operation snapshot recording. They strictly implement the confidentiality requirements of “dual-person management, clear responsibilities, and full traceability”. The product has multiple test reports and has been deployed in numerous party and government agencies and classified units. It can cooperate with users to pass security acceptance and special inspections.
Q3: Does the equipment have 3C certification? Are there any fire safety issues?
A: The full series of smart key cabinets have passed national 3C mandatory product certification, with electrical safety meeting national standards. The cabinet body is made of cold-rolled steel, and internal components are flame-retardant grade, providing excellent overall fire resistance. Optional built-in smoke and temperature detection modules can be linked to fire protection systems. Installation in conventional indoor office environments fully complies with fire safety regulations, presenting no fire hazards.
Q4: How long can operation records be stored? Do they meet audit requirements?
A: Local terminals store 100,000 operation records by default. Based on an average of 100 operations per day, this provides nearly 3 years of storage. The cloud platform has unlimited storage capacity, supporting permanent archival storage. All operation records use a hash verification mechanism, are non-tamperable, non-deletable, with precise timestamps. They can be exported in standard Excel format, fully meeting requirements for internal audits, special inspections, and judicial tracing. They are a strong technical support for unit compliance management.
14.6 Function Expansion and Customization Questions
Q1: Can the smart key cabinet integrate with our OA, access control, and visitor systems?
A: Yes, integration is supported. We provide standard RESTful API interfaces and SDK development kits, compatible with mainstream OA office systems, access control systems, visitor systems, vehicle management systems, and security integration platforms, enabling data exchange and linkage control. For example, after integrating with OA, OA approval automatically opens corresponding key permissions; after integrating with the visitor system, visitor registration automatically assigns temporary key permissions. Standard interface integration has a short cycle, and custom integration can be evaluated for development scope and timeline based on requirements.
Q2: Can you customize functions based on our management needs, such as special approval processes?
A: Yes, deep custom development is supported. We have an independent R&D team that can customize exclusive features based on industry characteristics and personalized management rules, such as custom multi-level approval processes, industry-specific reports, custom interface brand logos, special industry linkage rules, etc. For customization needs, contact business and technical personnel for on-site investigation, and a customization proposal and development timeline will be provided.
Q3: Can the cabinet color and size be customized? We want to match our office decoration style.
A: Yes, customization is available. Standard colors are matte gray and police blue. Other RAL colors can be customized based on user needs. Cabinet dimensions and slot layout can also be customized according to on-site space and key specifications, such as extended slots for large vehicle keys, or custom layered structures for irregular keys. Appearance printing and brand logos can also be customized to meet visual and branding requirements of different scenarios.
Q4: Can we add QR code door opening and mini-program key retrieval functions?
A: Yes, optional upgrades are available. A QR code scanning module can be installed. Users can submit borrowing requests, complete identity verification, and receive door opening authorization by scanning QR codes through WeChat mini-program. This is especially suitable for scenarios with many visitors and high personnel turnover, allowing temporary use without pre-registering biometric features. The mini-program also supports personal borrowing record queries, approval processing, alarm notification reception, and other functions, greatly improving convenience.
14.7 Procurement and Service Questions
Q1: Does the procurement package include on-site installation service? Or do we need to install it ourselves?
A: Standard procurement orders include professional engineer on-site installation and commissioning, providing one-stop service including cabinet fixing, wiring, debugging, and personnel training, ensuring the device is delivered and operational. No self-installation is needed. If users have their own construction team who wish to install, we can provide full technical guidance and correspondingly reduce installation fees.
Q2: How soon after ordering will the product be shipped? How long is the delivery time for customized models?
A: Standard models are kept in stock, and shipment is arranged within 3 working days after ordering. For orders with customized color, functions, or special specifications, the delivery cycle is 15-30 working days depending on customization complexity. Specific delivery cycles can be confirmed with business personnel at the time of ordering, ensuring project milestone timeliness.
Q3: How is after-sales service provided for non-local customers? Will response be slow?
A: We have established a nationwide service network. The Pearl River Delta region provides 24-hour on-site service, while other regions across the country receive 48-hour response and on-site service. Additionally, we offer a 7*24-hour technical service hotline. Most software and configuration issues can be resolved quickly through remote guidance. For on-site repairs, engineers from the nearest cooperative service point are dispatched. Non-local customers need not worry about after-sales response efficiency.
Chapter 15: Product Acceptance
Product acceptance is a core stage in equipment delivery and a necessary process for verifying whether equipment quality, functions, and performance comply with contract and standard requirements. This chapter clarifies the basis, stages, standards, and documentation requirements for acceptance, standardizes the entire acceptance process, and ensures project delivery quality.
15. Acceptance and Delivery
15.1 Acceptance Basis and Standards
Acceptance work must strictly follow relevant national standards, industry specifications, procurement contracts, technical agreements, and other documents. The main basis is as follows:
National Standards: *GB 50348 Technical Code for Security Engineering*, *GB 4943.1 Information Technology Equipment – Safety – Part 1: General Requirements*, *GB/T 17626 Electromagnetic Compatibility – Testing and Measurement Techniques*, *GB/T 28181 Technical Requirements for Information Transmission, Exchange and Control of Public Security Video Surveillance Networking System*, and other relevant national standards.
Industry Specifications: Key management specifications and equipment technical requirements for corresponding fields such as the security industry, confidentiality industry, electric power industry, and financial industry.
Contract Documents: Product models, parameters, functions, quantities, and service terms agreed upon in the procurement contract, technical agreement, and project design plan.
Enterprise Standards: Guangdong Lain enterprise product standards and factory inspection specifications, with all indicators higher than national general standards.
15.2 Acceptance Phase Division
The smart key cabinet project acceptance is divided into three progressive phases: factory acceptance, arrival acceptance, and installation commissioning acceptance (completion acceptance). The next phase may only proceed after the previous phase has passed acceptance.
15.2.1 Factory Acceptance
Factory acceptance is the quality acceptance conducted internally at the factory after production is completed and before shipment, executed by the manufacturer’s quality inspection department. User representatives may be invited to supervise the inspection.
Acceptance Purpose: Strictly control factory shipment quality, ensure delivered products meet standards and contract requirements, and ensure non-conforming products never leave the factory.
Acceptance Content: Appearance workmanship inspection, basic function power-on testing, core performance parameter inspection, accessories and consumables inventory check, and documentation review.
Acceptance Method: Implement a per-unit full inspection system; each unit must pass all factory inspection items and be issued a formal factory inspection report.
Acceptance Conclusion: Products that pass inspection are affixed with a qualification label and shipped with factory documentation; non-conforming products are marked for rework and re-inspected after repair is completed.
15.2.2 Arrival Acceptance
Arrival acceptance is the unboxing acceptance jointly conducted by both parties (Party A and Party B) after the equipment arrives at the project site, confirming no transportation damage and that the goods are consistent with the contract.
Acceptance Prerequisites: Equipment delivered to the location specified in the contract, outer packaging intact, and authorized personnel from both parties present.
Acceptance Content:
- Outer packaging inspection: Check whether the packaging box is intact, free from impact damage, water immersion, breakage, or secondary sealing marks, confirming no anomalies during transportation.
- Unboxing and inventory check: Against the packing list, verify the model and quantity of the equipment main unit, accessories, consumables, and documentation item by item, confirming completeness and correctness.
- Appearance inspection: Check for paint peeling, deformation, glass breakage, component damage, or other transportation damage on the equipment.
- Nameplate verification: Verify that the equipment model, factory serial number, and factory date match the contract.
Acceptance Process:
1. Both parties present on site, confirm outer packaging condition, and take photos for evidence.
2. Remove packaging, take out equipment and all accessories.
3. Check and verify item by item against the packing list.
4. Fill in the *Arrival Acceptance Form* and both parties sign for confirmation.
Exception Handling: If equipment damage, missing parts, or model discrepancies are found, photograph and record on site immediately. The manufacturer is responsible for replacement or exchange, and all related costs and schedule delays shall be borne by the manufacturer.
15.2.3 Installation Commissioning Acceptance (Completion Acceptance)
Installation commissioning acceptance is the comprehensive final acceptance after equipment installation and commissioning are completed, jointly executed by both parties. A third-party supervision unit may be invited when necessary. It marks the formal delivery of the project.
15.3 Complete Completion Acceptance Process
Step 1: Acceptance Condition Confirmation
Before organizing acceptance, confirm that all of the following conditions are met:
- Equipment installation, wiring, and commissioning are fully completed, all functions operate normally, meeting contract requirements.
- The manufacturer has completed operator training for Party A’s administrators and users, with passing assessments.
- All acceptance technical documentation is complete and ready.
- Equipment has completed no less than 72 hours of continuous fault-free trial operation, running stably without major failures.
- Party B submits a written acceptance application, and Party A confirms acceptance conditions are met.
Step 2: Establish Acceptance Team
Form a dedicated acceptance team including Party A’s project manager, user department representatives, and operation and maintenance management personnel, as well as Party B’s project engineer and after-sales engineer. For projects with supervision, include the supervision unit representative. The acceptance team is responsible for inspecting item by item according to the acceptance standards and issuing the acceptance conclusion.
Step 3: Item-by-Item Inspection and Testing
The acceptance team checks on-site inspections and functional demonstrations item by item against the acceptance checklist and standards, records inspection results truthfully, and conducts on-site measured verification of core functions and key indicators.
Step 4: Problem Rectification and Re-inspection
For general defects found during acceptance, issue a rectification list with clear rectification deadlines. Party B must complete rectification within the specified time and apply for re-inspection after completion. For major quality issues that cannot be rectified, handle according to the breach of contract clauses agreed in the contract.
Step 5: Sign Acceptance Report
After all acceptance items pass, both parties jointly sign the *Completion Acceptance Report* and affix official seals. The project is formally delivered and enters the warranty period. The acceptance report serves as the core basis for project settlement and warranty services.
15.4 Detailed Acceptance Items and Judgment Standards
15.4.1 Appearance and Installation Acceptance
| Acceptance Item | Acceptance Standard | Inspection Method | Pass Criteria |
|---|---|---|---|
| Cabinet appearance | Surface smooth and even, no paint peeling, scratches, deformation, or rust; coating uniform without runs; tempered glass free of damage and scratches | Full visual inspection, tactile check | Pass if all requirements met |
| Installation firmness | Wall-mounted units: no looseness or wobble, static load-bearing meets standard; floor-standing units: stable placement, no obvious wobble when pushed at top | Hand push test, wobble ≤ 2mm | Pass if firm and secure |
| Installation levelness | Cabinet horizontal deviation ≤ 2mm/m, vertical deviation ≤ 2mm/m | Magnetic level, plumb line measurement | Pass if deviation within range |
| Cabinet door performance | Smooth opening/closing, no jamming, no abnormal noise, tight closure, uniform door gap, maximum gap ≤ 2mm | Manual open/close test, feeler gauge measurement | Pass if smooth operation and uniform gap |
| Wiring specifications | Cables neatly tied, clear labeling, separate routing for power and signal lines, no exposed conductors, concealed and aesthetically pleasing routing | Full visual inspection | Pass if wiring is neat and standardized |
| On-site environment | No flammable or explosive items near equipment, fire protection facilities unobstructed, sufficient operating space | Visual inspection | Pass if environmental safety requirements met |
15.4.2 Hardware Function Acceptance
| Acceptance Item | Acceptance Standard | Inspection Method | Pass Criteria |
|---|---|---|---|
| Display and touch screen | Clear display without dead pixels or flickering, sensitive and accurate touch response, no drift, no touch dead zones | Full-screen point-by-point touch test, visual inspection | Pass if display and touch function normally |
| Facial recognition | Recognition accuracy ≥ 99%, recognition speed ≤ 1 second, supports binocular liveness detection, photos/videos cannot pass | 10 people test 5 times each, calculate success rate | Pass if overall success rate ≥ 95% |
| Fingerprint recognition | Recognition accuracy ≥ 98%, recognition speed ≤ 0.5 seconds, fake fingerprints cannot pass verification | 10 people test 5 times each, calculate success rate | Pass if overall success rate ≥ 95% |
| IC card recognition | Card reading distance 0-5cm, fast and accurate recognition, no missed reads or misreads | 10 authorized cards test 5 times each | Pass if all cards recognized successfully |
| Electric lock performance | All compartment locks unlock smoothly without abnormal noise, reliable locking, remain locked in power-off state | Test unlock and lock function compartment by compartment | Pass if 100% of compartments function normally |
| Presence detection | Key placed in compartment correctly detected as present, removed detected as absent, misplacement triggers automatic alarm, accuracy 100% | Test three scenarios per compartment: insert, remove, misplace | Pass if all judgments accurate |
| Indicator light status | Each compartment indicator light displays red/green status correctly, uniform brightness, no damaged or non-illuminated lights | Activate all indicator lights in test mode | Pass if all lights illuminate normally |
| Audible and visual alarm | Buzzer volume ≥ 80dB when alarm triggered, warning light flashes simultaneously, clear alert indication | Trigger alarm test, measure volume with sound level meter | Pass if audible and visual alarm functions normally |
| Power system | Mains power supply stable, UPS switching without interruption, emergency power supply function available | Power-off test for UPS switching, power bank test for emergency power supply | Pass if all functions operate normally |
15.4.3 Software Function Acceptance
| Acceptance Item | Acceptance Standard | Inspection Method | Pass Criteria |
|---|---|---|---|
| User management | Supports adding, deleting, and modifying user information, supports Excel batch import, supports three-level permission hierarchy | On-site operation: add users, assign permissions, batch import | Pass if functions complete and logic correct |
| Key management | Supports key entry, compartment binding, information modification, supports batch import/export of key information | On-site entry of keys, bind compartments, modify information | Pass if functions normal and data accurate |
| Permission control | Supports assigning key permissions by user, supports time-based permissions, duration limits, temporary authorization, automatic interception of unauthorized operations | Set up users with different permissions, test unauthorized key retrieval | Pass if permission control is precise |
| Access process | Complete retrieval and return process runs smoothly, convenient operation, real-time status updates | Simulate complete access process, end-to-end testing | Pass if process runs smoothly without lag |
| Record inquiry | Supports multi-dimensional combined queries by time, personnel, and key, accurate records, exportable to Excel reports | Query historical records, export reports for verification | Pass if records accurate and export functions normal |
| Alarm function | Abnormal events such as illegal door opening, overdue return, and misplaced keys trigger alarms normally, logs automatically retained | Simulate abnormal scenarios, test alarm triggering and recording | Pass if alarms are timely and accurate |
| Network communication | Wired/wireless network connection stable, timely data synchronization, no frequent disconnections | Test network connection, test local and cloud data synchronization | Pass if connection stable and synchronization normal |
| Approval process | Supports multi-level approval, permissions automatically granted after approval, clear prompt on rejection | Submit borrowing request, test complete approval process | Pass if process logic correct |
| Dual-person dual-lock | High-security model supports dual-person verification for door opening, single-person verification cannot operate | Test single-person and dual-person verification scenarios separately | Pass if dual-person verification is effective |
15.4.4 Performance and Stability Acceptance
- Continuous operation stability: Equipment operates continuously under power for 72 hours without crashes, abnormal restarts, or functional failures, stable and reliable.
- Concurrent operation performance: Execute 100 consecutive access operations; system responds promptly without lag, no data errors, complete and accurate records.
- Data accuracy: Number of operation logs exactly matches actual operation count; time, personnel, and key number information accurate, no missed or erroneous records.
- Power failure protection performance: Simulate sudden power failure; data not lost or corrupted; equipment automatically resumes operation after power restoration without manual intervention.
15.4.5 Documentation Acceptance
At acceptance, Party B must deliver complete technical documentation, including but not limited to:
- Product certificate of conformity, factory inspection report
- *Smart Key Cabinet Installation, Wiring, and Commissioning Manual* (paper version + electronic version)
- *Smart Key Cabinet Management Software Operation Manual*
- Product warranty card, after-sales service contact card
- Equipment list, accessory list, spare parts list
- Copies of qualification documents such as 3C certification certificate, ISO9001 quality system certification
- Training records, training courseware
- Completion acceptance report
15.5 Non-Conforming Acceptance Handling Specifications
General non-conforming items: Appearance defects, minor functional deficiencies, or missing documentation that do not affect core functions are classified as general non-conforming items. A rectification notice shall be issued with a deadline of 1-3 working days. Re-inspection shall be conducted after rectification is completed, and the acceptance report signed after passing re-inspection.
Serious non-conforming items: Core function failure, parameters seriously below standard, major safety hazards, or model mismatch with contract are classified as serious non-conforming items. Party B must issue a special rectification plan specifying the rectification period. Items that cannot be rectified shall be handled through return/exchange or compensation per the contract.
Re-inspection still non-conforming: If re-inspection fails after rectification, or rectification is not completed within the deadline, Party A has the right to pursue Party B’s liability for breach of contract per contract terms. In serious cases, return and refund processing may be implemented.
15.6 Formal Handover After Acceptance
After acceptance passes, the formal project handover is completed, including the following:
- Physical equipment handover, formally received and managed by Party A.
- Technical documentation, spare parts, and mechanical emergency keys all handed over to Party A.
- Super administrator account and password handed over, permission transition completed.
- After-sales service process and contact information communicated.
- Project handover confirmation letter signed; project formally enters warranty period.
After handover, Party B continues to provide warranty and after-sales service per contract terms, ensuring long-term stable operation of the equipment.
16. SEO Keyword System and Optimization Tags
16.1 Search Keyword Categorized Layout
16.1.1 Core Primary Keywords
Smart key cabinet, intelligent controlled key cabinet, smart key management cabinet, electronic key cabinet, RFID smart key cabinet
16.1.2 High-Conversion Long-Tail Keywords
Smart key cabinet manufacturer, smart key cabinet production factory, smart key cabinet price, smart key cabinet cost per unit, wall-mounted smart key cabinet, floor-standing smart key cabinet, facial recognition smart key cabinet, fingerprint smart key cabinet, smart key cabinet installation and commissioning, smart key cabinet solution, enterprise smart key cabinet, property management smart key cabinet, electric power smart key cabinet
16.1.3 Industry Traffic Keywords
Key intelligent management system, key cabinet intelligent management, smart key management system, RFID key management cabinet, electronic key management cabinet, key control system, smart key storage cabinet, smart key locker, networked smart key cabinet, dual-person dual-lock key cabinet, classified key cabinet, official vehicle key management cabinet
16.1.4 Brand-Specific Keywords
Lain smart key cabinet, Guangdong Lain key cabinet, Lain smart key cabinet, LA-YSG smart key cabinet, Guangzhou smart key cabinet manufacturer, Lain intelligent control equipment
16.1.5 Dropdown/Related Search Keywords
How to install smart key cabinet, smart key cabinet working principle, how to set permissions on smart key cabinet, which smart key cabinet brand is best, smart key cabinet common faults, how to choose a smart key cabinet, smart key cabinet dimensions and specifications, smart key cabinet acceptance standards
16.2 SEO Optimization Tag System
16.2.1 Page Core Optimization Tags
Page Type: Product technical manual / in-depth solution page
Core Optimization Direction: Comprehensively cover full-dimensional technical information on smart key cabinet products, installation, commissioning, and operation and maintenance; meet user search needs for product selection, construction, O&M, and fault troubleshooting; create a high-authority technical content page.
16.2.2 Title Tag
Smart Key Cabinet Installation, Wiring, and Commissioning Manual_Product Parameters_Functional Principles_Fault Troubleshooting – Guangdong Lain Smart Equipment Co., Ltd.
16.2.3 Meta Keywords
Smart key cabinet, smart key cabinet manual, smart key cabinet installation and commissioning, RFID smart key cabinet, facial recognition key cabinet, smart key cabinet manufacturer, Guangdong Lain smart key cabinet, key intelligent management system, smart key cabinet technical parameters, smart key cabinet common faults
16.2.4 Meta Description
Guangdong Lain Smart Equipment Co., Ltd. professionally researches, develops, and produces smart key cabinets and other intelligent control equipment. This manual provides detailed full-process technical content on smart key cabinet product introduction, composition structure, working principles, technical parameters, functional features, application scenarios, installation, wiring, commissioning methods, maintenance, fault troubleshooting, and acceptance standards, providing comprehensive and professional technical guidance for the deployment, implementation, and O&M management of smart key cabinets.
16.2.5 H1 Tag
Smart Key Cabinet Installation, Wiring, and Commissioning Manual
16.2.6 H2 Tags
Product Introduction, Product Composition, Product List, Product Working Principle, Product Technical Parameters, Product Functions and Features, Product Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Product Precautions, Product Repair and Maintenance, Product Common Problems and Solutions, Product QA, Product Acceptance
16.3 Internal Link Optimization Tags (Natural Anchor Text Placement)
16.3.1 Core Anchor Text
Smart key cabinet, smart key management system, RFID smart key cabinet
16.3.2 Long-Tail Anchor Text
Smart key cabinet manufacturer, wall-mounted smart key cabinet, facial recognition smart key cabinet, smart key cabinet installation and commissioning
16.3.3 Related Anchor Text
Intelligent control equipment, data center environment monitoring system, classified room shielding construction, smart security solutions
17. Copyright Statement and Contact Information
17.1 Copyright Statement
The copyright of this document is owned by Guangdong Lain Smart Equipment Co., Ltd. and is protected by the *Copyright Law of the People’s Republic of China*.
No unit or individual may, without the Company’s written authorization, reproduce, repost, excerpt, alter, compile, disseminate, or commercially utilize all or part of this document in any form, including but not limited to print publication, online reposting, secondary adaptation, and embedding into other product documentation.
Authorized reposting or citation must indicate the source as “Source: Guangdong Lain Smart Equipment Co., Ltd.” and must not distort or alter the original intent of this document, nor use it for commercial purposes.
The Company reserves the right to pursue legal liability for all infringements. The content of this document will be continuously updated with product technology iteration without further notice. The Company reserves the right of final interpretation.
17.2 Contact Us
Manufacturer: Guangdong Lain Smart Equipment Co., Ltd.
Service Hotline: +86 13538869979 (WhatsApp available)
Technical Support: +86 13538869979
Company Address: Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
Official Website: gdlain.com