The special shielding room for electromagnetic shielding protection is a closed hexahedral space constructed with high-conductivity/magnetic permeability metal materials based on the Faraday cage electromagnetic shielding principle. Combined with special components including filters, grounding systems, shielding doors and windows, it achieves isolation of electromagnetic interference and suppression of electromagnetic signal leakage.

As a dedicated protection facility, it mainly solves two core problems:

  1. External electromagnetic fields (radio waves, microwaves, industrial noise, etc.) interfering with precision indoor equipment, testing experiments and medical devices;
  2. Preventing internal confidential signals and high-frequency radiation from spreading outward, so as to guarantee data security, test accuracy and stable equipment operation.

This system covers four core application scenarios: anechoic shielding chambers, partial discharge shielding rooms, MRI shielding rooms and electron microscope shielding rooms. It strictly complies with national and military standards including GB12190-2006 Measurement Method of Shielding Effectiveness for Electromagnetic Shielding Enclosures, BMB3-1999 Technical Requirements for Electromagnetic Shielding Enclosures Processing Confidential Information, and GJB5792-2006 Military Standard for Shielding Effectiveness Classification of Confidential Information System Shielding Enclosures.

It meets high-frequency shielding demands in multiple industries such as scientific research testing, power industry, medical imaging and precision electronics, and provides three grades (basic, intermediate and premium) of standardized and customized full-scenario solutions.

2. System Composition

The shielding room system consists of four modules: core shielding enclosure, special shielding functional components, supporting auxiliary system and safety protection system. All modules work together to realize full-frequency and high-reliability electromagnetic shielding protection.

2.1 Core Shielding Enclosure

As the foundation of shielding, it adopts a fully enclosed hexahedral structure (wall, ceiling and floor). Three material options are available: cold-rolled steel plate (general type), copper plate (special for high frequency/MRI) and high-permeability steel plate (special for magnetic shielding). Welding or modular assembly processes are adopted to ensure electrical continuity, and conductive gaskets/copper strips are used to seal joints to eliminate electromagnetic leakage gaps.

2.2 Special Shielding Functional Components

  • Shielding door: Manual single/double door, motorized blade interlocking door. Triple sealing with copper-plated finger springs to block electromagnetic leakage through door gaps.
  • Shielded observation window: Double-layer copper mesh or metal-coated glass, balancing high light transmittance and superior shielding performance for observation requirements.
  • Power/signal filters: Suppress electromagnetic interference on power and signal lines, including single-phase/three-phase, high-current/low-current models.
  • Ventilation waveguide window: Honeycomb hexagonal structure that enables air circulation while blocking high-frequency electromagnetic waves.
  • Grounding system: Single-point grounding with low-resistance grounding electrodes, grounding resistance ≤1Ω to release induced charges on the enclosure.

2.3 Supporting Auxiliary System

  • Power supply system: Special shielding distribution cabinets, low-interference lighting (incandescent lamps/flicker-free LED lights) and shielded sockets.
  • Ventilation and air conditioning system: Special shielded air conditioners and waveguide ventilation ducts to regulate indoor temperature and humidity and realize air exchange.
  • Signal transfer system: Optical fiber transfer boxes, coaxial connectors and medical/test-specific waveguide interfaces to ensure signal transmission without leakage.

2.4 Safety Protection System

  • Fire linkage system: Smoke detectors and gas fire-extinguishing waveguides to meet fire compliance requirements.
  • Emergency escape system: Emergency unlocking devices for shielding doors and emergency lighting to ensure safe evacuation during power outages or emergencies.
  • Access control system: Fingerprint + password dual-authentication access control, suitable for permission management in confidential scenarios.

3. System Classification

Classification is implemented from four dimensions: application scenario, shielding effectiveness, structural process and protection type, to accurately match the demands of different scenarios.

3.1 Classification by Application Scenario (Core Classification)

  1. Electromagnetic Anechoic Shielding Chamber Inner walls are covered with wave-absorbing materials (ferrite + conical sponge) to simulate free space. Applied for EMC radiation emission/susceptibility testing, antenna R&D and 5G RF testing. Shielding effectiveness ≥100dB at 50MHz–1GHz.
  2. Partial Discharge Shielding Room Used for partial discharge tests of power equipment (switchgears, GIS, transformers, cable accessories). It isolates spatial electromagnetic interference to guarantee accurate partial discharge test data. Shielding effectiveness ≥100dB at 150kHz.
  3. MRI Shielding Room Adopts composite shielding layers: copper RF shielding layer + high-permeability steel magnetic shielding layer. It isolates external electromagnetic field interference on MRI imaging and suppresses strong magnetic field leakage of MRI equipment, compatible with permanent magnet and superconducting MRI devices.
  4. Electron Microscope Shielding Room High shielding effectiveness (≥100dB at 1GHz–10GHz). It isolates external vibration and electromagnetic interference to ensure clear imaging of scanning electron microscopes and transmission electron microscopes, suitable for precision detection in materials science and biomedicine.

3.2 Classification by Shielding Effectiveness

  • Basic Grade (Low): Shielding effectiveness ≥60dB at 30kHz–1GHz, for general precision instrument rooms and small laboratories.
  • Intermediate Grade (Medium): Shielding effectiveness ≥80dB at 150kHz–10GHz, for conventional EMC testing, power partial discharge tests and general medical imaging rooms.
  • Premium Grade (High): Shielding effectiveness ≥100dB at 9kHz–40GHz, for military confidential projects, 5G RF R&D, superconducting MRI and high-end electron microscope laboratories.

3.3 Classification by Structural Process

  • Welded Type: Formed by welding 2–3mm cold-rolled steel plates or copper plates. Features high shielding effectiveness, strong stability and a service life of 20–30 years, suitable for permanent fixed sites.
  • Modular Assembled Type: Prefabricated metal modules assembled on site and sealed with conductive gaskets. Detachable and relocatable with short construction cycles, suitable for temporary laboratories and mobile test stations.

3.4 Classification by Protection Type

  • Electromagnetic Shielding (Electric Field/Plane Wave): Cold-rolled steel plate material, suppresses radio waves and industrial electromagnetic interference, applicable to anechoic chambers and partial discharge rooms.
  • RF + Magnetic Composite Shielding: Composite material of copper plate + high-permeability steel plate, simultaneously suppresses RF interference and static magnetic field interference, dedicated to MRI shielding rooms.

4. System Schematic Diagrams

4.1 Overall structural schematic of shielding room

4.2 Power filter through-wall schematic

4.3 Electromagnetic sealing schematic of shielding door

5. Complete System Configuration List (KITOZER Brand, Basic / Intermediate / Premium Three Grades)

5.1 Basic Grade Configuration List (Basic Level, Shielding Effectiveness ≥60dB)

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Shielding Enclosure (Wall & Ceiling)KITOZER-SK-D011.5mm cold-rolled steel plate, modular assembly, hexahedral structure, sealed with conductive gaskets at joints, shielding effectiveness ≥60dB at 30kHz–1GHz1SetKITOZERWith aluminum alloy support keel and insulation overhead treatment
2Shielding Enclosure (Floor)KITOZER-SK-D022mm cold-rolled steel plate, modular assembly, equipped with anti-static grounding terminals, grounding resistance ≤1Ω1SetKITOZERLaid on insulation keel, moisture-proof and anti-corrosion
3Manual Single-Leaf Shielding DoorKITOZER-SM-D01Door opening 900×1900mm, 1mm galvanized steel door leaf, double-circle copper-plated finger springs, manual locking, shielding effectiveness ≥60dB1LeafKITOZERIncludes door frame, sealing strips and door lock
4Shielded Observation WindowKITOZER-CW-D01Size 600×800mm, single-layer copper mesh glass, light transmittance ≥70%, shielding effectiveness ≥60dB1LeafKITOZERWall-mounted installation
5Single-Phase Power FilterKITOZER-LB-D01220V/10A, insertion loss ≥60dB at 30kHz–1GHz, leakage current ≤0.5mA2UnitKITOZERIndoor and outdoor power transfer
6Ventilation Waveguide WindowKITOZER-BL-D01300×300mm hexagonal honeycomb structure, hole pitch 8mm, cut-off frequency 1GHz, shielding effectiveness ≥60dB2PieceKITOZER1 air inlet + 1 air outlet, for general ventilation
7Grounding SystemKITOZER-JD-D01Copper grounding electrodes (2 pieces × 5m), 16mm² copper grounding trunk cable, grounding resistance ≤1Ω1SetKITOZERSingle-point grounding with grounding box
8Shielded Distribution CabinetKITOZER-PD-D01300×400×200mm cold-rolled steel shell, built-in air switch and lightning arrester, shielding effectiveness ≥60dB1UnitKITOZERIndoor main power control
9Flicker-Free LED Explosion-Proof LightKITOZER-LM-D01220V/18W, flicker-free, IP54 explosion-proof grade, low electromagnetic radiation4LampKITOZERIndoor lighting to avoid electromagnetic interference
10Shielded SocketKITOZER-CZ-D015-hole 10A, shielded shell, contact resistance ≤0.01Ω6PieceKITOZERPower supply for indoor equipment

5.2 Intermediate Grade Configuration List (Advanced Level, Shielding Effectiveness ≥80dB)

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Shielding Enclosure (Wall & Ceiling)KITOZER-SK-M012mm cold-rolled steel plate, welded structure, fully enclosed hexahedron, joints sealed by copper strip welding, shielding effectiveness ≥80dB at 150kHz–10GHz1SetKITOZERWith galvanized square tube support frame and anti-corrosion coating
2Shielding Enclosure (Floor)KITOZER-SK-M022.5mm cold-rolled steel plate, welded structure, equipped with equipotential grounding terminals, grounding resistance ≤0.8Ω1SetKITOZERInsulation overhead, load capacity ≥500kg/㎡
3Motorized Blade Interlocking Shielding DoorKITOZER-SM-M01Door opening 1200×2100mm, 1.5mm cold-rolled steel door leaf, triple copper-plated finger springs, motorized blade locking + manual emergency unlock, shielding effectiveness ≥80dB1LeafKITOZERWith access control and fire linkage interface
4Shielded Observation WindowKITOZER-CW-M01Size 800×1000mm, double-layer copper mesh glass, light transmittance ≥65%, shielding effectiveness ≥80dB1LeafKITOZERAnti-fog and explosion-proof treatment
5Three-Phase Power FilterKITOZER-LB-M01380V/32A, insertion loss ≥80dB at 150kHz–10GHz, leakage current ≤0.3mA1UnitKITOZERFor high-power equipment power supply
6Single-Phase Power FilterKITOZER-LB-M02220V/16A, insertion loss ≥80dB at 150kHz–10GHz, leakage current ≤0.2mA3UnitKITOZERPower supply for lighting and auxiliary equipment
7Ventilation Waveguide WindowKITOZER-BL-M01400×400mm hexagonal honeycomb structure, hole pitch 6mm, cut-off frequency 5GHz, shielding effectiveness ≥80dB4PieceKITOZER2 air inlets + 2 air outlets, for forced ventilation
8Signal FilterKITOZER-XH-M01RJ45 interface, insertion loss ≥80dB at 1MHz–10GHz, transmission rate 1000Mbps2PieceKITOZERShielded transmission of network signals
9Grounding SystemKITOZER-JD-M01Pure copper grounding electrodes (3 pieces × 8m), 25mm² copper grounding trunk cable, grounding resistance ≤0.8Ω1SetKITOZERSingle-point equipotential grounding with anti-corrosion treatment
10Special Shielded Air ConditionerKITOZER-KT-M011.5HP cooling & heating type, power/signal lines fully filtered, shielded shell, cooling capacity 3500W1UnitKITOZERIndoor temperature & humidity control (22±2℃)
11Shielded Distribution CabinetKITOZER-PD-M01400×500×250mm welded cold-rolled steel shell, built-in air switch, lightning arrester and filter, shielding effectiveness ≥80dB1UnitKITOZERSplit power supply with overload protection
12Flicker-Free LED Purification LightKITOZER-LM-M01220V/24W, flicker-free, IP65 purification grade, extremely low electromagnetic radiation6LampKITOZERIndoor lighting for clean environments
13Shielded SocketKITOZER-CZ-M015-hole 16A, thickened shielded shell, contact resistance ≤0.005Ω8PieceKITOZERPower supply for precision equipment
14Smoke DetectorKITOZER-YG-M01Photoelectric type, operating voltage 220V, filtered alarm signal, response time ≤3s1UnitKITOZERFire early warning for shielding environments

5.3 Premium Grade Configuration List (Professional Level, Shielding Effectiveness ≥100dB)

表格

No.Product NameModel SpecificationTechnical ParametersQtyUnitBrandRemarks
1Shielding Enclosure (Wall & Ceiling)KITOZER-SK-H013mm cold-rolled steel plate / 0.5mm copper plate (MRI special), welded fully enclosed hexahedron, joints sealed by argon arc welding, shielding effectiveness ≥100dB at 9kHz–40GHz1SetKITOZERWith high-strength aluminum alloy support and military-grade anti-corrosion coating
2Shielding Enclosure (Floor)KITOZER-SK-H023mm cold-rolled steel plate / 1mm copper plate (MRI special), welded structure, full equipotential grounding, grounding resistance ≤0.5Ω1SetKITOZERInsulation overhead, load capacity ≥1000kg/㎡, seismic resistance Grade 8
3Motorized Blade Interlocking Double-Leaf Shielding DoorKITOZER-SM-H01Door opening 2000×2400mm, 2mm cold-rolled steel door leaf, quadruple copper-plated finger springs, motorized blade locking + fingerprint/password access control + fire linkage, shielding effectiveness ≥100dB1LeafKITOZERWith emergency escape device and automatic door closing function
4High-Performance Shielded Observation WindowKITOZER-CW-H01Size 1000×1200mm, composite glass with three layers of copper mesh + metal coating, light transmittance ≥60%, shielding effectiveness ≥100dB1LeafKITOZERRadiation-proof, anti-electromagnetic interference and bulletproof treatment
5Three-Phase High-Current Power FilterKITOZER-LB-H01380V/63A, insertion loss ≥100dB at 9kHz–40GHz, leakage current ≤0.1mA, wide temperature range -25℃~+85℃1UnitKITOZERMilitary grade, for high-power precision equipment
6Single-Phase Power FilterKITOZER-LB-H02220V/20A, insertion loss ≥100dB at 9kHz–40GHz, leakage current ≤0.1mA4UnitKITOZERSpecial for lighting and auxiliary equipment
7Ventilation Waveguide WindowKITOZER-BL-H01500×500mm hexagonal honeycomb structure, hole pitch 4.2mm, cut-off frequency 20GHz, shielding effectiveness ≥100dB6PieceKITOZER3 air inlets + 3 air outlets, for precision constant temperature ventilation
8Multi-Channel Signal FilterKITOZER-XH-H01Multi-interface (RJ45/BNC/Fiber), insertion loss ≥100dB at 1MHz–40GHz, supports 10Gbps transmission3PieceKITOZERShielded transmission of RF, network and optical fiber signals
9Magnetic Shielding Assembly (MRI Special)KITOZER-CI-H011mm thick high-permeability steel plate, composite shielding layer, magnetic field shielding effectiveness ≥100dB at 14kHz1SetKITOZERMeet magnetic shielding requirements of MRI rooms
10Grounding SystemKITOZER-JD-H01High-purity copper grounding electrodes (4 pieces × 10m), 35mm² pure copper grounding trunk cable, grounding resistance ≤0.5Ω1SetKITOZERFull equipotential grounding with long-term anti-corrosion treatment, military standard
11Precision Constant Temperature & Humidity Shielded Air ConditionerKITOZER-KT-H013HP, constant temperature & humidity, temperature control accuracy ±0.5℃, humidity 40%-60%, fully filtered lines, shielded shell1UnitKITOZERFor precision instruments and medical equipment environment
12Special Shielded Distribution CabinetKITOZER-PD-H01500×600×300mm pure copper shielded shell, built-in military-grade air switch, lightning arrester and filter, shielding effectiveness ≥100dB1UnitKITOZERIntelligent split power supply with remote monitoring and overload protection
13Flicker-Free LED Medical/Precision LightKITOZER-LM-H01220V/30W, flicker-free, IP68 purification grade, zero electromagnetic radiation, color temperature 5000K8LampKITOZERLighting for high-end precision laboratories and medical rooms
14High-Performance Shielded SocketKITOZER-CZ-H015-hole 20A, pure copper shielded shell, gold-plated contacts, contact resistance ≤0.001Ω10PieceKITOZERMilitary grade for precision equipment
15Composite Smoke & Temperature DetectorKITOZER-YG-H01Photoelectric + thermal composite type, operating voltage 220V, fully filtered alarm signal, response time ≤1s2UnitKITOZERMilitary-grade fire early warning for confidential environments
16Fire Extinguishing Gas Waveguide PipeKITOZER-MH-H01Compatible with heptafluoropropane fire suppression, cut-off frequency 20GHz, shielding effectiveness ≥100dB1SetKITOZERShielded transfer of fire extinguishing gas pipelines

6. Full Product Technical Parameters

6.1 Shielding Enclosure

  • Material: Basic grade – 1.5mm cold-rolled steel plate (modular); Intermediate grade – 2mm cold-rolled steel plate (welded); Premium grade – 3mm cold-rolled steel plate / 0.5mm copper plate (welded).
  • Shielding Effectiveness: Basic ≥60dB at 30kHz–1GHz; Intermediate ≥80dB at 150kHz–10GHz; Premium ≥100dB at 9kHz–40GHz.
  • Structure: Fully enclosed hexahedron. Basic grade assembled with conductive gasket sealing; Intermediate & Premium grade welded with copper strip/argon arc welding sealing.
  • Grounding: Basic ≤1Ω, Intermediate ≤0.8Ω, Premium ≤0.5Ω, single-point / full equipotential grounding.
  • Service Life: Basic 15–20 years; Intermediate & Premium 20–30 years, seismic resistance Grade 8.

6.2 Shielding Door

  • Type: Basic – manual single-leaf; Intermediate – motorized blade interlocking single-leaf; Premium – motorized blade interlocking double-leaf.
  • Door Leaf Material: Basic – 1mm galvanized steel; Intermediate – 1.5mm cold-rolled steel; Premium – 2mm cold-rolled steel.
  • Sealing Structure: Basic – double-circle finger springs; Intermediate – triple finger springs; Premium – quadruple copper-plated finger springs.
  • Shielding Effectiveness: Basic ≥60dB, Intermediate ≥80dB, Premium ≥100dB.
  • Extra Functions: Intermediate with access control & fire linkage; Premium with fingerprint/password recognition, emergency escape and automatic door closing.

6.3 Shielded Observation Window

  • Material: Basic – single-layer copper mesh glass; Intermediate – double-layer copper mesh glass; Premium – composite glass with three layers of copper mesh + metal coating.
  • Light Transmittance: Basic ≥70%, Intermediate ≥65%, Premium ≥60%.
  • Shielding Effectiveness: Basic ≥60dB, Intermediate ≥80dB, Premium ≥100dB.
  • Size: Basic 600×800mm; Intermediate 800×1000mm; Premium 1000×1200mm.

6.4 Power Filter

  • Voltage Specifications: Basic 220V/10A; Intermediate 220V/16A, 380V/32A; Premium 220V/20A, 380V/63A.
  • Insertion Loss: Basic ≥60dB at 30kHz–1GHz; Intermediate ≥80dB at 150kHz–10GHz; Premium ≥100dB at 9kHz–40GHz.
  • Leakage Current: Basic ≤0.5mA, Intermediate ≤0.3mA, Premium ≤0.1mA.
  • Operating Temperature: Basic 0℃~+40℃; Intermediate -10℃~+60℃; Premium -25℃~+85℃.

6.5 Ventilation Waveguide Window

  • Size: Basic 300×300mm; Intermediate 400×400mm; Premium 500×500mm.
  • Structure: Hexagonal honeycomb. Hole pitch: Basic 8mm, Intermediate 6mm, Premium 4.2mm.
  • Cut-off Frequency: Basic 1GHz, Intermediate 5GHz, Premium 20GHz.
  • Shielding Effectiveness: Basic ≥60dB, Intermediate ≥80dB, Premium ≥100dB.

6.6 Grounding System

  • Grounding Electrodes: Basic – 2 copper electrodes × 5m; Intermediate – 3 pure copper electrodes × 8m; Premium – 4 high-purity copper electrodes × 10m.
  • Grounding Trunk Cable: Basic ≥16mm² copper cable; Intermediate ≥25mm² copper cable; Premium ≥35mm² pure copper cable.
  • Grounding Resistance: Basic ≤1Ω, Intermediate ≤0.8Ω, Premium ≤0.5Ω, full-system equipotential connection.

6.7 Special Shielded Air Conditioner

  • Cooling Capacity: Basic 1HP; Intermediate 1.5HP; Premium 3HP.
  • Temperature Control Accuracy: Basic ±2℃; Intermediate ±1℃; Premium ±0.5℃.
  • Humidity Control: Intermediate 40%-70%; Premium 40%-60% (constant temperature & humidity).
  • Shielding Treatment: Power/signal lines fully filtered, shielded shell, shielding effectiveness ≥80dB (Intermediate) / ≥100dB (Premium).

7. Full Product Application Scope

7.1 Shielding Enclosure

  • Electromagnetic Anechoic Chamber: EMC testing, antenna R&D, 5G RF testing, wireless equipment performance inspection.
  • Partial Discharge Shielding Room: Partial discharge tests of power switchgears, GIS, transformers, cable accessories and transformers.
  • MRI Shielding Room: Hospital permanent magnet/superconducting MRI equipment, medical imaging detection, biomagnetic signal research.
  • Electron Microscope Shielding Room: Scanning electron microscope, transmission electron microscope, atomic force microscope, precision detection for materials science and biomedical microanalysis.
  • Confidential Computer Room: Military confidential data storage, government confidential information processing, secure communication machine rooms.

7.2 Shielding Door

  • Access passages of all shielding rooms for personnel and equipment passage, ensuring electromagnetic tightness of shielding rooms.
  • Confidential sites: Secure laboratories, military workshops, confidential areas of data centers for shielding protection.
  • Medical shielding rooms: Access passages of MRI rooms and electron microscope rooms, balancing shielding performance and passage convenience.

7.3 Shielded Observation Window

  • Electromagnetic Anechoic Chamber: Observe internal test processes without external interference.
  • Partial Discharge Shielding Room: Monitor test status of power equipment to guarantee test safety.
  • MRI Shielding Room: Medical staff observe patient status while isolating magnetic field interference.
  • Electron Microscope Shielding Room: Monitor electron microscope operation and sample status to stabilize imaging quality.

7.4 Power/Signal Filter

  • Power supply system of shielding rooms: Filter grid electromagnetic interference to prevent interference from entering shielding rooms.
  • Precision instruments: Power filtering for electron microscopes, MRI and RF equipment to ensure stable operation.
  • Confidential communication equipment: Filter electromagnetic leakage of signal lines to avoid interception of confidential information.
  • Industrial control equipment: Signal filtering for PLC and servo systems to prevent control failure caused by electromagnetic interference.

7.5 Ventilation Waveguide Window

  • Ventilation system of shielding rooms: Realize indoor-outdoor air exchange while blocking leakage/invasion of high-frequency electromagnetic waves.
  • Constant temperature & humidity laboratories: Maintain stable indoor electromagnetic environment while ensuring ventilation.
  • Medical shielding rooms: Ventilation for MRI and electron microscope rooms to meet equipment heat dissipation and personnel breathing demands.

7.6 Grounding System

  • All shielding rooms: Release induced charges on shielding enclosures, reduce grounding resistance, guarantee shielding performance and personnel safety.
  • Precision instruments: Grounding for electron microscopes, MRI and RF equipment to avoid static accumulation and electromagnetic interference.
  • Confidential sites: Ensure safe equipment grounding and prevent confidential information leakage caused by electrostatic discharge.

7.7 Special Shielded Air Conditioner

  • Electromagnetic Anechoic Chamber: Stabilize test environment temperature and humidity to ensure accurate EMC test data.
  • Electron Microscope Shielding Room: Precision constant temperature & humidity control to avoid imaging drift caused by temperature fluctuation.
  • MRI Shielding Room: Meet heat dissipation demands of MRI equipment and stabilize equipment operating environment.

8. Full Product Advantages

8.1 General Advantages of Full Series

  1. Customized Design: Support non-standard size, special shielding effectiveness and dedicated interface customization to match personalized demands of various scenarios.
  2. OEM & ODM Service: Provide OEM/ODM processing of shielding components, production according to customer drawings, suitable for bulk procurement and brand customization.
  3. Confidential Production: Military-grade production process, sign non-disclosure agreements, strictly control technical parameters and project information to meet confidential scenario requirements.
  4. In-Stock Supply: Standard shielding enclosures, shielding doors, filters and other components are in regular stock to shorten delivery cycles and quickly respond to customer demands.
  5. Full-Range Technical Parameters: Cover three grades of shielding effectiveness (Basic/Intermediate/Premium), fully matching scenarios from ordinary laboratories to military confidential projects and high-end medical facilities.
  6. Superior Shielding Performance: Maximum shielding effectiveness of core products reaches ≥100dB at 9kHz–40GHz, complying with national and military standards with outstanding electromagnetic isolation effect.
  7. Long Service Life & Stable Performance: Intermediate & Premium grades adopt high-quality cold-rolled steel/copper plates with anti-corrosion coating, service life 20–30 years, seismic resistance Grade 8, stable long-term operation.
  8. Safe & Reliable: Full-system grounding resistance ≤1Ω, shielding doors equipped with emergency escape devices, compatible with fire linkage to protect personnel and equipment safety.

8.2 Special Advantages of Each Product

  • Shielding Enclosure: Welded structure delivers excellent electrical continuity without electromagnetic leakage; modular assembled type is detachable and relocatable with short construction cycles, flexible for site changes.
  • Shielding Door: Triple/quadruple copper-plated finger spring sealing ensures door gap shielding effectiveness consistent with enclosure; motorized blade interlocking locking delivers tight sealing for high-frequency shielding demands.
  • Power Filter: Wide frequency band and high insertion loss to filter full-spectrum electromagnetic interference; military-grade products operate under wide temperature ranges for harsh environments.
  • Ventilation Waveguide Window: Honeycomb hexagonal structure with high ventilation efficiency, maximum cut-off frequency up to 20GHz, balancing ventilation and shielding performance.
  • Grounding System: High-purity copper grounding electrodes with low and stable grounding resistance and long-term anti-corrosion treatment, suitable for high shielding effectiveness scenarios.

9. Bid Evaluation Technical Parameters of All Products (Marked with *)

9.1 Shielding Enclosure

    • Material: Basic ≥1.5mm cold-rolled steel plate (modular); Intermediate ≥2mm cold-rolled steel plate (welded); Premium ≥3mm cold-rolled steel plate / ≥0.5mm copper plate (welded).
    • Shielding Effectiveness: Basic ≥60dB at 30kHz–1GHz; Intermediate ≥80dB at 150kHz–10GHz; Premium ≥100dB at 9kHz–40GHz.
    • Grounding Resistance: Basic ≤1Ω, Intermediate ≤0.8Ω, Premium ≤0.5Ω.
    • Structural Process: Intermediate & Premium grades adopt welded structure with copper strip/argon arc welding sealing at joints; Basic grade adopts modular assembly with conductive gasket sealing.
    • Service Life: ≥20 years (Intermediate & Premium), seismic resistance ≥Grade 8.

9.2 Shielding Door

    • Door Opening Size: Basic ≥900×1900mm; Intermediate ≥1200×2100mm; Premium ≥2000×2400mm.
    • Door Leaf Material: Basic ≥1mm galvanized steel; Intermediate ≥1.5mm cold-rolled steel; Premium ≥2mm cold-rolled steel.
    • Sealing Structure: Basic ≥ double-circle finger springs; Intermediate ≥ triple finger springs; Premium ≥ quadruple copper-plated finger springs.
    • Shielding Effectiveness: Basic ≥60dB, Intermediate ≥80dB, Premium ≥100dB.
    • Extra Functions: Intermediate with access control & fire linkage; Premium with fingerprint/password recognition, emergency escape and automatic door closing.

9.3 Shielded Observation Window

    • Size: Basic ≥600×800mm; Intermediate ≥800×1000mm; Premium ≥1000×1200mm.
    • Material: Basic – single-layer copper mesh glass; Intermediate – double-layer copper mesh glass; Premium – composite glass with three layers of copper mesh + metal coating.
    • Light Transmittance: Basic ≥70%, Intermediate ≥65%, Premium ≥60%.
    • Shielding Effectiveness: Basic ≥60dB, Intermediate ≥80dB, Premium ≥100dB.

9.4 Power Filter

    • Voltage Specifications: Basic 220V/≥10A; Intermediate 220V/≥16A, 380V/≥32A; Premium 220V/≥20A, 380V/≥63A.
    • Insertion Loss: Basic ≥60dB at 30kHz–1GHz; Intermediate ≥80dB at 150kHz–10GHz; Premium ≥100dB at 9kHz–40GHz.
    • Leakage Current: Basic ≤0.5mA, Intermediate ≤0.3mA, Premium ≤0.1mA.
    • Operating Temperature: Premium -25℃~+85℃, Intermediate -10℃~+60℃.

9.5 Ventilation Waveguide Window

    • Size: Basic ≥300×300mm; Intermediate ≥400×400mm; Premium ≥500×500mm.
    • Hole Pitch: Basic ≤8mm, Intermediate ≤6mm, Premium ≤4.2mm.
    • Cut-off Frequency: Basic ≥1GHz, Intermediate ≥5GHz, Premium ≥20GHz.
    • Shielding Effectiveness: Basic ≥60dB, Intermediate ≥80dB, Premium ≥100dB.

9.6 Grounding System

    • Grounding Electrodes: Basic ≥2 copper electrodes ×5m; Intermediate ≥3 pure copper electrodes ×8m; Premium ≥4 high-purity copper electrodes ×10m.
    • Grounding Trunk Cable: Basic ≥16mm² copper cable; Intermediate ≥25mm² copper cable; Premium ≥35mm² pure copper cable.
    • Grounding Resistance: Basic ≤1Ω, Intermediate ≤0.8Ω, Premium ≤0.5Ω.

10. Full Product Solution Packages

10.1 Electromagnetic Anechoic Chamber Solution

  • Core Demand: Simulate free space, isolate external electromagnetic interference to guarantee accurate EMC testing and antenna R&D data.
  • Configuration Scheme: Premium grade shielding enclosure (3mm cold-rolled steel welded), shielding effectiveness ≥100dB at 9kHz–40GHz; inner walls covered with ferrite + conical sponge wave-absorbing materials, reflection loss ≥15dB at 30MHz–40GHz; equipped with motorized blade interlocking double-leaf shielding door, high-performance shielded observation window, multi-channel signal filter and precision constant temperature shielding air conditioner; adopt 500×500mm ventilation waveguide window (cut-off frequency 20GHz); grounding system with high-purity copper electrodes, grounding resistance ≤0.5Ω.
  • Implementation Key Points: Weld shielding enclosure without gaps, lay wave-absorbing materials evenly without voids, fully filter all power and signal lines to eliminate electromagnetic leakage.

10.2 Partial Discharge Shielding Room Solution

  • Core Demand: Isolate spatial electromagnetic interference to ensure accurate partial discharge test data of power equipment, meet safety standards of high-voltage tests.
  • Configuration Scheme: Intermediate grade shielding enclosure (2mm cold-rolled steel welded), shielding effectiveness ≥80dB at 150kHz–10GHz; equipped with motorized blade interlocking single-leaf shielding door, double-layer copper mesh shielded observation window, 32A three-phase power filter and 400×400mm ventilation waveguide window; grounding resistance ≤0.8Ω with equipotential connection; indoor explosion-proof lighting and smoke detectors to comply with high-voltage test safety specifications.
  • Implementation Key Points: Reliable grounding of shielding enclosure, insulation between high-voltage test area and shielding enclosure, shielded pipe sealing for line through-wall to avoid interference invasion.

10.3 MRI Shielding Room Solution

  • Core Demand: Isolate external RF/magnetic field interference for clear MRI imaging, suppress strong magnetic field leakage of MRI equipment to protect surrounding equipment and human safety.
  • Configuration Scheme: Premium grade composite shielding enclosure (0.5mm copper RF shielding layer + 1mm high-permeability steel magnetic shielding layer), RF shielding effectiveness ≥100dB at 9kHz–40GHz, magnetic field shielding effectiveness ≥100dB at 14kHz; equipped with motorized blade interlocking single-leaf shielding door, three-layer copper mesh shielded observation window, medical special signal filter and precision constant temperature & humidity shielding air conditioner; adopt 500×500mm ventilation waveguide window; high-purity copper grounding system, grounding resistance ≤0.5Ω with full equipotential connection; reserve medical gas waveguide interfaces and ECG monitoring system interfaces.
  • Implementation Key Points: Insulate magnetic shielding layer from RF shielding layer, reinforce floor load capacity of MRI equipment placement area ≥1000kg/㎡, strictly control magnetic field leakage within safe range.

10.4 Electron Microscope Shielding Room Solution

  • Core Demand: Isolate external electromagnetic interference and vibration to guarantee stable clear imaging of scanning/transmission electron microscopes, meet precision detection demands of materials science.
  • Configuration Scheme: Premium grade shielding enclosure (3mm cold-rolled steel welded), shielding effectiveness ≥100dB at 9kHz–40GHz; equipped with motorized blade interlocking single-leaf shielding door, three-layer copper mesh shielded observation window, multi-channel signal filter and precision constant temperature & humidity shielding air conditioner (temperature accuracy ±0.5℃); adopt 500×500mm ventilation waveguide window; grounding resistance ≤0.5Ω with full-system equipotential connection; floor vibration isolation treatment to prevent vibration transfer affecting electron microscope imaging.
  • Implementation Key Points: Insulate shielding enclosure from floor vibration isolation layer, separate grounding for electron microscope equipment, fully filter all lines, strictly control indoor temperature and humidity to avoid imaging drift caused by environmental fluctuation.

11. Full Product Application Cases

11.1 Confidential Shielded Computer Room Project of Military Enterprise

  • Project Scale: 12m(L) ×8m(W) ×3.5m(H), Premium grade shielding room, shielding effectiveness ≥100dB at 9kHz–40GHz.
  • Configured Products: KITOZER Premium shielding enclosure, motorized blade interlocking double-leaf shielding door, high-performance shielded observation window, military-grade power/signal filters, high-purity copper grounding system, precision constant temperature shielding air conditioner.
  • Project Effect: Passed inspection in accordance with BMB3-1999 standard of State Secrets Bureau, electromagnetic leakage ≤0.01μW/cm², fully meeting confidential information processing requirements, stable operation without failure for 5 years.

11.2 High-Voltage Partial Discharge Laboratory Project of Power Group

  • Project Scale: 10m(L) ×6m(W) ×4m(H), Intermediate grade shielding room, shielding effectiveness ≥80dB at 150kHz–10GHz.
  • Configured Products: KITOZER Intermediate shielding enclosure, motorized blade interlocking single-leaf shielding door, double-layer copper mesh shielded observation window, three-phase power filter, ventilation waveguide window, equipotential grounding system.
  • Project Effect: Effectively isolates external industrial electromagnetic interference, background noise of partial discharge test ≤5pC, meets accuracy requirements of partial discharge inspection for GIS, transformers and other high-voltage equipment, completed over 1000 sets of equipment testing.

11.3 MRI Shielding Room Project of Grade A Tertiary Hospital

  • Project Scale: 8m(L) ×7m(W) ×3m(H), Premium grade composite shielding room, RF shielding effectiveness ≥100dB, magnetic field shielding effectiveness ≥100dB.
  • Configured Products: KITOZER Premium composite shielding enclosure (copper + high-permeability steel), motorized shielding door, medical special shielded observation window, medical signal filter, constant temperature & humidity shielding air conditioner, high-purity copper grounding system.
  • Project Effect: No artifacts in MRI imaging with significantly improved image definition, magnetic field leakage controlled below 0.5mT to protect normal operation of surrounding medical equipment, receiving over 30 patients per day.

11.4 Electron Microscope Laboratory Project of University Materials Science Department

  • Project Scale: 9m(L) ×7m(W) ×3.2m(H), Premium grade shielding room, shielding effectiveness ≥100dB at 9kHz–40GHz.
  • Configured Products: KITOZER Premium shielding enclosure, motorized shielding door, high-performance shielded observation window, multi-channel signal filter, precision constant temperature & humidity shielding air conditioner, vibration isolation grounding system.
  • Project Effect: Isolates external electromagnetic interference and vibration, imaging resolution of scanning electron microscope reaches 0.1nm, meets micro-structure detection demands of nanomaterials and biological tissues, supports publication of multiple high-level academic papers.

12. Product Faults, Maintenance & Servicing

12.1 Common Faults & Troubleshooting Methods

  1. Degraded Shielding Effectiveness
  • Causes: Cracked joints of shielding enclosure, deformed finger springs, damaged filters, excessive grounding resistance.
  • Troubleshooting: Inspect welds/assembly gaps of enclosure and repair cracks; replace deformed finger springs; test filter insertion loss and replace damaged units; measure grounding resistance, inspect grounding electrodes/trunk cables and rework grounding if exceeding standard.
  1. Poor Sealing of Shielding Door
  • Causes: Aging & deformed finger springs, deformed door leaf, loose locking mechanism.
  • Troubleshooting: Replace aging finger springs; correct door leaf flatness; fasten locking mechanism and adjust blade position to ensure uniform sealing of door gaps.
  1. Power Interference Invading Shielding Room
  • Causes: Damaged power filters, unfiltered lines, incorrect filter wiring.
  • Troubleshooting: Test filter insertion loss and replace damaged units; inspect all power lines to ensure full filtering; recheck filter wiring and correct wrong connections.
  1. Electromagnetic Leakage of Ventilation System
  • Causes: Deformed waveguide window, damaged honeycomb structure, unsealed installation gaps.
  • Troubleshooting: Correct flatness of waveguide window; repair damaged honeycomb structure; seal installation gaps to eliminate leakage points.
  1. Grounding Faults
  • Causes: Corroded grounding electrodes, broken trunk cables, loose grounding terminals.
  • Troubleshooting: Replace corroded grounding electrodes; repair broken trunk cables; fasten grounding terminals and re-measure grounding resistance to qualified value.

12.2 Maintenance & Servicing Regulations

  1. Daily Maintenance (Every Day)
  • Inspect finger springs of shielding door, clean surface dust and debris, avoid scratching springs with hard objects.
  • Observe shielding enclosure surface for rust or cracks, clean stains timely.
  • Inspect appearance of filters and waveguide windows to ensure no deformation or damage.
  • Monitor indoor temperature and humidity to guarantee normal operation of air conditioning system.
  1. Monthly Maintenance (Every Month)
  • Tighten all connecting bolts of shielding door and enclosure to prevent loosening.
  • Measure grounding resistance to meet standard: ≤1Ω (Basic), ≤0.8Ω (Intermediate), ≤0.5Ω (Premium).
  • Test operating status of power/signal filters and record insertion loss data.
  • Clean honeycomb structure of ventilation waveguide window to remove dust and debris for smooth ventilation.
  1. Annual Deep Maintenance (Every Year)
  • Full inspection of enclosure welds and joints, repair cracks with supplementary welding and re-seal gaps.
  • Replace aging finger springs and sealing strips of shielding door.
  • Performance test of all filters, replace units with attenuated performance.
  • Excavate and inspect grounding system, replace corroded grounding electrodes and re-lay grounding trunk cables.
  • Entire shielding effectiveness test by third-party inspection institution and issue test report.
  1. Maintenance Precautions
  • Do not hit or scratch shielding enclosure, finger springs and waveguide windows with hard objects during maintenance to avoid damage.
  • Cut off power supply before electrical maintenance, operated by professional electricians to prevent electric shock risks.
  • Adopt original KITOZER spare parts for replacement to match shielding performance.
  • Keep detailed maintenance records including maintenance date, content, test data and replaced parts for traceability.

13. Factory Strength & After-Sales Service

13.1 Factory Strength

  1. Production Scale: KITOZER owns a 10,000㎡ modern production base equipped with CNC cutting machines, laser welding machines, precision bending machines and full-band shielding effectiveness testers. Annual capacity reaches over 500 sets of shielding rooms and over 10,000 shielding components to fulfill bulk order delivery demands.
  2. Technical Team: A professional R&D team of more than 50 staff including over 10 senior engineers, dedicated to electromagnetic shielding technology R&D for over 10 years, holding more than 20 patents and leading formulation of multiple industry standards with domestically leading technical level.
  3. Production Process: Adopt military-grade production process, comply with ISO9001 quality management system certification, full-process quality control from raw material procurement, processing, assembly debugging to factory inspection, strict quality check of every procedure to guarantee stable and reliable product quality.
  4. Inspection Capacity: Equipped with professional shielding effectiveness testing laboratory with full-band testers (9kHz–40GHz), network analyzers and grounding resistance testers. All products pass 100% inspection before delivery to ensure qualified shielding effectiveness.
  5. Supply Chain Advantage: Long-term strategic cooperation with high-quality domestic steel, copper and electronic component suppliers to guarantee raw material quality and controllable procurement cost for cost-effective products.

13.2 After-Sales Service

  1. Quality Warranty: 3-year free warranty for full product series, free repair and spare parts replacement for non-artificial damage within warranty period; 5-year extended warranty available for Intermediate & Premium grades with lifetime maintenance service.
  2. Installation & Commissioning: Free on-site installation and commissioning service, professional engineers guide on-site assembly and debug shielding effectiveness to qualified standard for normal equipment operation; provide installation drawings and video tutorials for remote guidance.
  3. Technical Support: 7×24-hour technical hotline, professional technicians online to answer inquiries, provide technical consultation, fault troubleshooting and operation training; regular online/offline technical training to help customers master product operation and maintenance skills.
  4. Rapid Response: Respond within 2 hours upon fault repair request, arrive on-site within 24 hours nationwide to resolve faults timely and minimize customer loss; coordinate nearby service outlets for remote areas to shorten response time.
  5. Customized Service: Provide non-standard product customization, system solution optimization, OEM processing and confidential production according to special customer demands, one-on-one technical docking throughout the whole process to meet personalized requirements.
  6. Return Visit Service: Regular customer return visits to track equipment operation status and collect feedback for continuous product and service optimization; one free on-site inspection per year to troubleshoot hidden faults in advance.

14. Conclusion

As core facilities for electromagnetic environment governance, special shielding rooms for electromagnetic shielding protection play an irreplaceable role in scientific research testing, power industry, medical imaging and precision electronics sectors, serving as critical physical barriers to guarantee test accuracy, stable equipment operation and information security.

KITOZER special shielding room system relies on military-grade technology, strict quality control and full-scenario adaptability, covering four core scenarios: anechoic shielding chambers, partial discharge shielding rooms, MRI shielding rooms and electron microscope shielding rooms. It provides three grades (Basic/Intermediate/Premium) of integrated standardized and customized solutions with high shielding performance, stable operation and long service life, fully complying with national and military standards.

In the future, KITOZER will continue to deepen R&D of electromagnetic shielding technology, continuously optimize product performance and upgrade service quality, and deliver efficient and reliable electromagnetic shielding protection solutions to global customers with advanced technology, premium products and comprehensive services, supporting high-quality development of all industries.

15. Search Keywords, SEO & Tags

15.1 Search Keywords

  • Core Keywords: Special Shielding Room for Electromagnetic Shielding Protection, Electromagnetic Shielding Room, Electromagnetic Anechoic Chamber, Partial Discharge Shielding Room, MRI Shielding Room, Electron Microscope Shielding Room
  • Long-Tail Keywords: KITOZER Shielding Room, EMC Test Shielding Room, Power Partial Discharge Shielding Room, Hospital MRI Shielding Room, Precision Electron Microscope Shielding Room, Military Confidential Shielding Room, High Shielding Effectiveness Shielding Room, Customized Shielding Room

15.2 SEO Optimization

Title Optimization: Place core keywords at the front, e.g. “KITOZER Special Electromagnetic Shielding Room – Solution for Anechoic Chamber / Partial Discharge Room / MRI Room / Electron Microscope Room”

15.3 Tags

  • Industry Tags: #ElectromagneticShielding #ShieldingRoom #EMCTesting #PowerEquipment #MedicalImaging #PrecisionInstrument #ScientificResearchTesting
  • Product Tags: #KITOZER #ElectromagneticAnechoicChamber #PartialDischargeShieldingRoom #MRIShieldingRoom #ElectronMicroscopeShieldingRoom #CustomShieldingRoom
  • Scenario Tags: #MilitaryConfidential #Hospital #UniversityLaboratory #PowerGroup #ElectronicsFactory
Shopping Cart