Table of Contents
Toggle1 System Introduction
The standard prefabricated container machine room is an integrated data center infrastructure prefabricated and fully assembled in factories with factory acceptance testing, complying with ISO standard container dimensions (20ft/40ft). It serves as the core form of prefabricated enclosure modular data centers. The system highly integrates cabinets, power supply & distribution, cooling, fire protection, security, environmental monitoring, and structured cabling subsystems inside a standard container enclosure. It features five core strengths: full factory prefabrication, integrated delivery, ultra-fast deployment, intelligent operation & maintenance, and superior environmental adaptability. It can realize “finished product upon factory delivery, ready for deployment on site, and operational once powered on”, drastically shortening construction cycles, lowering site requirements, and boosting computing power delivery efficiency.
KITOZER standard prefabricated container machine rooms fully comply with the TIA-942 Data Center Telecommunications Infrastructure Standard and Uptime Institute Modular Data Center Specifications. The enclosure adopts 2.0mm cold-rolled steel plates with polyurethane thermal insulation layers, reaching an IP55 protection rating. It can withstand extreme temperatures ranging from -40℃ to +55℃, Level 12 strong winds, and Zone 3 seismic activity. It is suitable for full-scenario deployment including field sites, mining areas, ports, emergency disaster backup, edge computing, and smart cities, acting as an efficient alternative to traditional machine rooms.
2 System Composition
The KITOZER standard prefabricated container machine room consists of 10 core subsystems with deeply integrated modules operating collaboratively to form a fully closed-loop infrastructure system with no external dependencies (only mains power and network access required):
- Container Enclosure Subsystem: Standard 20ft/40ft cabinet, load-bearing frame, thermal insulation layer, waterproof sealing structure, lightning protection & grounding system, emergency escape door, ventilation louvers, cable entry & exit ports
- Cabinet Subsystem: Standard 19-inch IT cabinets, server cabinets, network cabinets, UPS cabinets, battery cabinets, hot & cold aisle containment components
- Power Supply & Distribution Subsystem: Dual mains input, UPS uninterruptible power supply, battery pack, precision power distribution cabinet, rack-mounted PDU, ATS automatic transfer switch, lightning arrester, cables and cable trays
- Precision Cooling Subsystem: In-row precision air conditioners, air-cooled/water-cooled units, hot & cold aisle isolation devices, fan coil units, dehumidification modules, fresh air system
- Fire Suppression Subsystem: Smoke & temperature detectors, heptafluoropropane gas fire suppression units, emergency lighting, audible & visual alarms, fire blocking materials
- Security Monitoring Subsystem: Access control (card swiping/fingerprint/password), high-definition video surveillance, infrared intrusion detection, door magnetic sensors
- Environmental Monitoring Subsystem: Temperature & humidity sensors, water leakage detection sensors, smoke sensors, intelligent monitoring host, local touch screen, remote management platform
- Structured Cabling Subsystem: Cat6/Cat6A unshielded twisted pairs, 10G fiber jumpers, patch panels, cable managers, cable trays, identification system
- Intelligent Management Subsystem: Exclusive KITOZER monitoring software, centralized control platform, remote operation & maintenance module, alarm push system, energy consumption statistics module
- Auxiliary Subsystem: Emergency lighting, evacuation indicators, grounding system, identification signs, maintenance walkways, load-bearing reinforcement structures
3 System Classification
3.1 Classification by Cabinet Size
- 20ft Standard Type (6058mm×2438mm×2896mm): Suitable for small-to-medium computing demands; accommodates 5–6 standard cabinets with single cabinet power density ≤8kW and total IT load ≤48kW. Ideal for edge computing, branch offices, and small-scale disaster backup scenarios.
- 40ft Standard Type (12192mm×2438mm×2896mm): Suitable for medium-to-large computing demands; accommodates 12–15 standard cabinets with single cabinet power density ≤18kW and total IT load ≤270kW. Ideal for data center expansion, large-scale disaster backup, and mining/oil field computing stations.
- Custom Size Type: Supports non-standard lengths (10ft/30ft) and heights (2400mm/3000mm) to fit special site and power requirements.
3.2 Classification by Functional Positioning
- All-in-One Integrated Type: Fully integrated with IT cabinets, UPS, batteries, cooling, fire protection and monitoring subsystems, capable of independent operation without external supporting facilities. Suitable for field sites with no supporting infrastructure.
- IT Load Type: Only integrated with cabinets, cooling, monitoring and cabling subsystems, with centralized external power supply & distribution. Suitable for modular expansion of large data centers.
- Power Supporting Type: Integrated with UPS, batteries, power distribution cabinets and lightning protection subsystems, with externally connected IT cabinets and cooling units. Suitable for power capacity expansion of existing machine rooms.
- Emergency Disaster Backup Type: Reinforced seismic resistance, waterproofing and rapid deployment capabilities, equipped with mobile hoisting structures. Suitable for emergency computing support after sudden disasters.
3.3 Classification by Cooling Mode
- Air-Cooled Type: In-row air conditioners + air-cooled outdoor units, flexible deployment with no water source required. Suitable for water-shortage/field scenarios with PUE ≤1.3.
- Water-Cooled Type: In-row air conditioners + water-cooled units with high cooling efficiency and PUE ≤1.15. Suitable for high-density computing scenarios.
- Free Cooling Type: Fresh air + heat exchange system, enabling free cooling under low load to cut energy consumption. Suitable for mild climate regions.
3.4 Classification by Power Density
- Low-Density Type: Single cabinet power ≤5kW, total load ≤60kW. Suitable for basic office and regular server deployment.
- Medium-Density Type: Single cabinet power 5–12kW, total load ≤180kW. Suitable for virtualization, cloud computing and small-to-medium database deployment.
- High-Density Type: Single cabinet power 12–18kW, total load ≤270kW. Suitable for AI computing, big data analysis and high-performance computing.
4 System Schematic Diagrams
4.1 Overall Architecture Schematic
Mains input → Lightning protection system → ATS automatic transfer switch → UPS uninterruptible power supply → Precision power distribution cabinet → Rack-mounted PDU → IT equipment Cooling cycle: Indoor in-row air conditioner absorbs heat → Outdoor unit dissipates heat → Cold air recirculates → Hot & cold aisle isolation enables precise cooling of IT equipment Fire linkage: Smoke/temperature detection → Signal transmission to monitoring host → Trigger heptafluoropropane fire suppression → Activate emergency lighting Monitoring closed loop: Temperature/humidity/water leakage/access control/camera sensors → Data collection → Intelligent monitoring host → Local display + remote alarm + linkage control
4.2 Power Supply & Distribution System Schematic
Dual mains power (primary & backup) → Lightning arrester → ATS transfer switch → 1+1 redundant UPS → Battery pack → Precision power distribution cabinet (incoming + outgoing cabinets) → Rack-mounted PDU (cabinet-level power distribution) → Servers/switches and other IT equipment Backup power interface: Supports external generator connection with automatic ATS switching to ensure seamless power transition during outages.
4.3 Cooling System Schematic
- Air-cooled type: In-row precision air conditioner supplies cold air → Cold aisle → IT equipment absorbs heat → Hot aisle → Air conditioner air return → Outdoor unit heat dissipation → Circulating cooling
- Water-cooled type: In-row air conditioner → Cooling water circulation → Water-cooled unit → Cooling tower → Cooled water flows back to air conditioner → Circulating cooling Hot & cold aisle containment adopts blanking panels and sealing strips to isolate hot and cold airflow, avoiding air mixing and boosting cooling efficiency by over 30%.
4.4 Monitoring System Schematic
Front-end sensors (temperature/humidity, water leakage, smoke, access control, cameras) → Data collector → Intelligent monitoring host → Local touch screen (real-time display) + remote management platform (Web/APP) → Alarm push (SMS/WeChat/Email) → Linked control (air conditioner start/stop, fire suppression, access lockout)
5 Full System Configuration List (KITOZER Brand, Low/Medium/High Density Classifications)
5.1 Low-End Version (20ft, Low Density, Air-Cooled, Single Cabinet ≤5kW)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Standard Container Enclosure | KITOZER-20FT-L | 20ft (6058×2438×2896mm), 2.0mm cold-rolled steel plate, 50mm polyurethane insulation, IP55 protection, Grade 8 seismic resistance, waterproof sealing, lightning protection & grounding, escape door, cable ports | 1 | Set | KITOZER | Basic low-end model, no customization |
| 2 | IT Cabinet | KITOZER-C6042-L | 600×1000×2000mm, 42U, 19-inch standard, 1.5mm cold-rolled steel, 800kg load capacity, mesh door, silent fans, detachable side panels | 5 | Unit | KITOZER | Includes blanking panels & cable managers |
| 3 | UPS Uninterruptible Power Supply | KITOZER-UPS-10KVA-L | 10KVA/9KW, online double conversion, single-in single-out, efficiency ≥92%, backup time ≥30min, LCD display, overload protection | 1 | Unit | KITOZER | Standalone, no redundancy |
| 4 | Battery Pack | KITOZER-BATT-12V100AH-L | 12V 100AH, valve-regulated lead-acid maintenance-free, float voltage 13.5–13.8V, ≥500 charge-discharge cycles, flame-retardant housing | 16 | Piece | KITOZER | Matched for 10KVA UPS |
| 5 | Precision Power Distribution Cabinet | KITOZER-PDU-380V-L | 380V/100A, 1 incoming circuit, 8 outgoing circuits, circuit breaker protection, power meter monitoring, cold-rolled steel, IP40 protection | 1 | Unit | KITOZER | Simplified low-end model |
| 6 | Rack-Mounted PDU | KITOZER-R-PDU-16A-L | 16A, 8×C13 + 2×C19 outlets, 380V input, max power 48kW, surge protection, aluminum housing | 5 | Unit | KITOZER | 1 per cabinet |
| 7 | In-Row Precision Air Conditioner | KITOZER-AC-12KW-L | 12KW cooling capacity, air-cooled, supply air temp 18–24℃, temperature accuracy ±1℃, dehumidification, airflow 3000m³/h, noise ≤55dB | 2 | Unit | KITOZER | N configuration, no redundancy |
| 8 | Air-Cooled Outdoor Unit | KITOZER-OUT-12KW-L | Matched for 12KW air conditioner, airflow 5000m³/h, rust-proof & waterproof, IP54 protection | 2 | Unit | KITOZER | Matched with in-row air conditioners |
| 9 | Hot & Cold Aisle Containment Assembly | KITOZER-C/H-L | Adapted for 20ft enclosure, top cold aisle containment, blanking panels + sealing strips, flame-retardant, dust & waterproof | 1 | Set | KITOZER | Basic containment, no skylight |
| 10 | Smoke Detector | KITOZER-SMOKE-L | Photoelectric type, sensitivity 0.15–0.3dB/m, 12V operating voltage, normally open alarm output, dust-proof housing | 4 | Piece | KITOZER | Evenly distributed on ceiling |
| 11 | Heptafluoropropane Fire Suppression Unit | KITOZER-FM-40L-L | 40L tank, heptafluoropropane agent, filling pressure 1.2MPa, 24V startup voltage, extinguishing concentration ≤8%, residue-free | 1 | Set | KITOZER | Single tank, automatic startup only |
| 12 | Access Controller | KITOZER-ACC-L | Card swipe + password, single-door control, card reading distance 5–10cm, 12V, stores 1000 access records | 1 | Unit | KITOZER | Includes card reader & electromagnetic lock |
| 13 | HD Camera | KITOZER-CAM-L | 1080P, infrared night vision, IP66 waterproof, 110° wide angle, 32G storage, 12V | 2 | Unit | KITOZER | 1 at entrance, 1 internal |
| 14 | Temperature & Humidity Sensor | KITOZER-T/H-L | Temp -40℃~+80℃, humidity 0–100%RH, accuracy ±0.5℃/±3%RH, RS485 output, 12V | 3 | Piece | KITOZER | Cold aisle, hot aisle, entrance |
| 15 | Water Leak Detection Cable | KITOZER-LEAK-L | 10m detection length, liquid leakage sensing, switch output, 12V, corrosion-resistant | 2 | Roll | KITOZER | Under air conditioners & cable trenches |
| 16 | Intelligent Monitoring Host | KITOZER-MON-L | 4-core CPU, 4G RAM, 500G storage, supports 16 sensor inputs, 7-inch LCD touch screen, Web remote management | 1 | Unit | KITOZER | Basic low-end model, no APP support |
| 17 | Structured Cabling Assembly | KITOZER-CAB-L | Cat6 UTP, 10G fiber jumpers, 24-port patch panels, cable managers, galvanized trays, identification labels | 1 | Batch | KITOZER | Cabling for 5 cabinets |
5.2 Mid-End Version (20ft, Medium Density, Air-Cooled, Single Cabinet 5–12kW)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Standard Container Enclosure | KITOZER-20FT-M | 20ft (6058×2438×2896mm), 2.0mm cold-rolled steel, 50mm polyurethane insulation, IP55, Grade 9 seismic resistance, waterproof sealing, lightning protection, escape door, customizable LOGO | 1 | Set | KITOZER | Reinforced mid-end model, LOGO customization available |
| 2 | IT Cabinet | KITOZER-C6042-M | 600×1100×2200mm, 42U, 19-inch standard, 2.0mm cold-rolled steel, 1200kg load capacity, mesh + tempered glass door, 4 silent fans, adjustable trays | 6 | Unit | KITOZER | Includes blanking panels, cable managers & trays |
| 3 | UPS Uninterruptible Power Supply | KITOZER-UPS-20KVA-M | 20KVA/18KW, online double conversion, three-in single-out, efficiency ≥95%, backup ≥60min, LCD touch screen, supports 1+1 redundancy | 2 | Unit | KITOZER | 1+1 redundant configuration |
| 4 | Battery Pack | KITOZER-BATT-12V150AH-M | 12V 150AH VRLA lead-acid, float voltage 13.5–13.8V, ≥800 charge-discharge cycles, flame-retardant housing, -20℃ low temp resistance | 32 | Piece | KITOZER | 16 pieces per 20KVA UPS |
| 5 | Precision Power Distribution Cabinet | KITOZER-PDU-380V-M | 380V/250A, dual primary/backup incoming circuits, 12 outgoing circuits, smart power meter, circuit breaker + leakage protection, IP40, audible & visual alarm | 1 | Unit | KITOZER | Smart mid-end model, dual input |
| 6 | Rack-Mounted PDU | KITOZER-R-PDU-32A-M | 32A, 12×C13 + 4×C19 outlets, 380V input, surge protection, aluminum housing, remote switch control | 6 | Unit | KITOZER | 1 per cabinet, remotely controllable |
| 7 | In-Row Precision Air Conditioner | KITOZER-AC-25KW-M | 25KW cooling capacity, air-cooled, supply air temp 16–22℃, accuracy ±0.5℃, dehumidification + humidification, airflow 6000m³/h, noise ≤50dB, supports N+1 redundancy | 3 | Unit | KITOZER | N+1 redundant configuration |
| 8 | Air-Cooled Outdoor Unit | KITOZER-OUT-25KW-M | Matched for 25KW AC, airflow 10000m³/h, rust-proof IP54 housing, silent fans | 3 | Unit | KITOZER | Matched with in-row air conditioners |
| 9 | Hot & Cold Aisle Containment Assembly | KITOZER-C/H-M | Full containment for 20ft enclosure, openable top skylight, flame-retardant ABS blanking panels & sealing strips, dust-proof, waterproof & anti-static | 1 | Set | KITOZER | Full containment with skylight |
| 10 | Combined Smoke & Temperature Detector | KITOZER-S/T-M | Photoelectric smoke + 57℃ temperature dual detection, sensitivity 0.15–0.3dB/m, 24V, normally open alarm output, dust & waterproof | 6 | Piece | KITOZER | Evenly distributed on ceiling & between cabinets |
| 11 | Heptafluoropropane Fire Suppression Unit | KITOZER-FM-70L-M | 70L tank, heptafluoropropane agent, filling pressure 1.2MPa, 24V startup, extinguishing concentration ≤8%, auto + manual dual startup | 2 | Set | KITOZER | Dual tanks, zoned fire suppression |
| 12 | Access Controller | KITOZER-ACC-M | Card swipe + password + fingerprint, dual-door control, card reading distance 5–15cm, 12V, stores 5000 access records, remote door opening | 1 | Unit | KITOZER | Includes card reader, fingerprint module & electromagnetic lock |
| 13 | HD Camera | KITOZER-CAM-M | 4K resolution, infrared night vision, IP67 waterproof, 140° wide angle, 128G storage, motion detection | 4 | Unit | KITOZER | 1 at entrance, internal, cable area |
| 14 | Temperature & Humidity Sensor | KITOZER-T/H-M | Temp -40℃~+80℃, humidity 0–100%RH, accuracy ±0.3℃/±2%RH, RS485 + Ethernet dual output, 12V | 5 | Piece | KITOZER | Cold aisle, hot aisle, entrance, AC zone |
| 15 | Water Leak Detection Cable | KITOZER-LEAK-M | 20m detection length, liquid leakage sensing, switch + Ethernet output, 12V, corrosion-resistant, 1m positioning precision | 3 | Roll | KITOZER | Under ACs, cable trenches, entrance |
| 16 | Intelligent Monitoring Host | KITOZER-MON-M | 6-core CPU, 8G RAM, 1T storage, supports 32 sensor inputs, 10-inch LCD touch screen, Web + APP remote management, SMS/WeChat alarm push | 1 | Unit | KITOZER | Smart mid-end model with APP remote access |
| 17 | Structured Cabling Assembly | KITOZER-CAB-M | Cat6A UTP, 10G fiber jumpers, 48-port patch panels, cable managers, galvanized flame-retardant trays, identification labels | 1 | Batch | KITOZER | Flame-retardant cabling for 6 cabinets |
5.3 High-End Version (40ft, High Density, Water-Cooled, Single Cabinet 12–18kW)
表格
| No. | Product Name | Model | Technical Parameters | Qty | Unit | Brand | Remarks |
|---|---|---|---|---|---|---|---|
| 1 | Standard Container Enclosure | KITOZER-40FT-H | 40ft (12192×2438×2896mm), 2.5mm cold-rolled steel, 80mm polyurethane insulation, IP55, Grade 10 seismic resistance, waterproof sealing, lightning protection, escape door, customizable LOGO & appearance, anti-static floor | 1 | Set | KITOZER | Reinforced high-end full-custom model |
| 2 | IT Cabinet | KITOZER-C6048-H | 600×1200×2200mm, 48U, 19-inch standard, 2.5mm cold-rolled steel, 1500kg load capacity, mesh + tempered glass door, 6 silent fans, adjustable trays, anti-static treatment | 15 | Unit | KITOZER | Includes blanking panels, cable managers, trays & anti-static accessories |
| 3 | UPS Uninterruptible Power Supply | KITOZER-UPS-40KVA-H | 40KVA/36KW, online double conversion, three-in three-out, efficiency ≥97%, backup ≥90min, LCD touch screen, overvoltage/short circuit/lightning protection, supports 2N redundancy | 4 | Unit | KITOZER | 2N redundant configuration |
| 4 | Battery Pack | KITOZER-BATT-12V200AH-H | 12V 200AH VRLA lead-acid, float voltage 13.5–13.8V, ≥1000 charge-discharge cycles, flame-retardant housing, -30℃ ultra-low temp resistance, high-rate discharge | 64 | Piece | KITOZER | 16 pieces per 40KVA UPS |
| 5 | Precision Power Distribution Cabinet | KITOZER-PDU-380V-H | 380V/500A, dual primary/backup incoming circuits, 24 outgoing circuits, smart power meter, circuit breaker + leakage + lightning protection, IP54, audible & visual alarm + remote monitoring | 2 | Unit | KITOZER | High-end smart model, dual input with remote monitoring |
| 6 | Rack-Mounted PDU | KITOZER-R-PDU-63A-H | 63A, 16×C13 + 8×C19 outlets, 380V input, surge/overcurrent protection, aluminum housing, remote switch + real-time energy monitoring | 15 | Unit | KITOZER | 1 per cabinet with energy consumption monitoring |
| 7 | In-Row Precision Air Conditioner | KITOZER-AC-40KW-H | 40KW cooling capacity, water-cooled, supply air temp 14–20℃, accuracy ±0.3℃, dehumidification + humidification + fresh air, airflow 12000m³/h, noise ≤45dB, supports 2N redundancy | 6 | Unit | KITOZER | 2N redundant configuration |
| 8 | Water-Cooled Chiller Unit | KITOZER-WATER-40KW-H | Matched for 40KW in-row AC, total cooling capacity 240KW, inlet water temp 12℃, outlet 18℃, silent water pumps, IP54 rust-proof housing | 2 | Unit | KITOZER | 2N redundant configuration |
| 9 | Hot & Cold Aisle Containment Assembly | KITOZER-C/H-H | Full containment for 40ft enclosure, motorized lifting skylight, flame-retardant PC blanking panels & sealing strips, dust-proof, waterproof & anti-static, automatic lifting | 1 | Set | KITOZER | Full containment with motorized automatic skylight |
| 10 | Combined Smoke, Temperature & CO Detector | KITOZER-S/T-H | Triple detection: photoelectric smoke + 57℃ temperature + carbon monoxide, sensitivity 0.15–0.3dB/m, 24V, normally open alarm output, dust/water/explosion-proof | 12 | Piece | KITOZER | Evenly distributed on ceiling, between cabinets & cable zones |
| 11 | Heptafluoropropane Fire Suppression Unit | KITOZER-FM-120L-H | 120L tank, heptafluoropropane agent, filling pressure 1.2MPa, 24V startup, extinguishing concentration ≤8%, auto + manual + remote triple startup, explosion-proof | 4 | Set | KITOZER | Four tanks, zoned & layered fire suppression |
| 12 | Access Controller | KITOZER-ACC-H | Card swipe + password + fingerprint + facial recognition, four-door control, card reading distance 5–20cm, 12V, stores 10000 access records, remote door opening + facial authentication | 2 | Unit | KITOZER | Includes card reader, fingerprint module, facial terminal & electromagnetic lock |
| 13 | HD Camera | KITOZER-CAM-H | 8K resolution, infrared night vision, IP68 waterproof, 180° ultra-wide angle, 256G storage, motion detection + human shape identification + abnormal alarm | 8 | Unit | KITOZER | Installed at entrance, internal area, cable zone & AC zone |
| 14 | Temperature & Humidity Sensor | KITOZER-T/H-H | Temp -40℃~+80℃, humidity 0–100%RH, accuracy ±0.2℃/±1%RH, RS485 + Ethernet + wireless triple output, 12V, explosion-proof | 10 | Piece | KITOZER | Cold aisle, hot aisle, entrance, AC zone, cable zone |
| 15 | Water Leak Detection Cable | KITOZER-LEAK-H | 30m detection length, liquid leakage sensing, switch + Ethernet + wireless output, 12V, corrosion-resistant, 0.5m high-precision positioning, explosion-proof | 5 | Roll | KITOZER | Under ACs, cable trenches, entrance & water cooling zone |
| 16 | Intelligent Monitoring Host | KITOZER-MON-H | 8-core CPU, 16G RAM, 2T storage, supports 64 sensor inputs, 15-inch LCD touch screen, Web + APP + mini-program remote management, SMS/WeChat/Email multi-channel alarm push, AI energy efficiency optimization | 2 | Unit | KITOZER | Flagship high-end model with AI energy optimization |
| 17 | Structured Cabling Assembly | KITOZER-CAB-H | 10G UTP, 40G fiber jumpers, 96-port patch panels, cable managers, stainless steel trays, identification labels, flame-retardant cable troughs, fiber storage boxes | 1 | Batch | KITOZER | Stainless steel flame-retardant cabling for 15 cabinets |
6 Full Product Technical Specifications
6.1 Container Enclosure Technical Specifications
- Standard Dimensions: 20ft (6058×2438×2896mm) / 40ft (12192×2438×2896mm), non-standard customization available
- Steel Plate Thickness: Low/mid-end: 2.0mm cold-rolled steel; High-end: 2.5mm cold-rolled steel
- Thermal Insulation: Polyurethane foam layer; Low/mid-end: 50mm; High-end: 80mm, thermal conductivity ≤0.03W/(m·K)
- Protection Rating: IP55 (fully dust-proof, resistant to low-pressure water spray)
- Seismic Resistance: Low-end Grade 8, Mid-end Grade 9, High-end Grade 10, withstands Zone 3 seismic activity
- Ambient Adaptability: Operating temperature -40℃ ~ +55℃, relative humidity 10%–90%RH (non-condensing)
- Load-Bearing Capacity: Floor load ≥1000kg/㎡, Roof load ≥500kg/㎡
- Lightning Protection & Grounding: Ground resistance ≤4Ω, direct & induced lightning protection, compliant with GB50057 standard
6.2 IT Cabinet Technical Specifications
- Dimensions: 600×(1000/1100/1200)×(2000/2200)mm, 42U/48U, standard 19-inch rack
- Steel Thickness: Low-end 1.5mm, Mid-end 2.0mm, High-end 2.5mm cold-rolled steel
- Load Capacity: Low-end 800kg, Mid-end 1200kg, High-end 1500kg
- Door Design: Low-end full mesh door; Mid-end mesh + tempered glass door; High-end mesh + tempered glass + anti-static treatment
- Cooling Fans: Low-end ≥2 silent fans; Mid-end ≥4 silent fans; High-end ≥6 silent fans, airflow ≥300m³/h
- Standard Accessories: Blanking panels, cable managers, adjustable trays, detachable side panels, locks; High-end adds anti-static floor
6.3 UPS Uninterruptible Power Supply Technical Specifications
- Rated Capacity: Low-end 10KVA/9KW; Mid-end 20KVA/18KW; High-end 40KVA/36KW
- Input/Output Format: Low-end single-in single-out; Mid-end three-in single-out; High-end three-in three-out
- Operation Mode: Online double conversion, automatic switching between mains/battery/bypass
- Efficiency: Low-end ≥92%, Mid-end ≥95%, High-end ≥97%
- Full-Load Backup Time: Low-end ≥30min, Mid-end ≥60min, High-end ≥90min
- Protection Functions: Overload, overvoltage, short circuit, undervoltage, lightning protection; High-end adds overtemperature protection
- Redundancy Mode: Low-end standalone; Mid-end 1+1 redundant parallel; High-end 2N redundant parallel
6.4 Battery Pack Technical Specifications
- Nominal Voltage: 12V per cell
- Nominal Capacity: Low-end 100AH, Mid-end 150AH, High-end 200AH
- Type: Valve-regulated sealed lead-acid maintenance-free
- Float Voltage: 13.5–13.8V (25℃ ambient)
- Charge-Discharge Cycle Life: Low-end ≥500 cycles, Mid-end ≥800 cycles, High-end ≥1000 cycles (100% depth of discharge)
- Operating Temperature: -20℃~+40℃; High-end supports -30℃ ultra-low temperature
- Housing: Flame-retardant ABS, anti-corrosion & leak-proof
6.5 In-Row Precision Air Conditioner Technical Specifications
- Cooling Capacity: Low-end 12KW, Mid-end 25KW, High-end 40KW
- Cooling Type: Low/Mid-end air-cooled; High-end water-cooled
- Supply Air Temperature Range: Low-end 18–24℃, Mid-end 16–22℃, High-end 14–20℃
- Temperature Control Accuracy: Low-end ±1℃, Mid-end ±0.5℃, High-end ±0.3℃
- Airflow Volume: Low-end 3000m³/h, Mid-end 6000m³/h, High-end 12000m³/h
- Noise Level: Low-end ≤55dB, Mid-end ≤50dB, High-end ≤45dB
- Built-in Functions: Low-end cooling + dehumidification; Mid-end cooling + dehumidification + humidification; High-end cooling + dehumidification + humidification + fresh air ventilation
- Redundancy Mode: Low-end N configuration; Mid-end N+1 redundant; High-end 2N redundant
6.6 Fire Suppression System Technical Specifications
- Detectors: Low-end photoelectric smoke detector; Mid-end combined smoke & temperature detector; High-end triple smoke/temperature/CO composite detector
- Detection Sensitivity: Smoke 0.15–0.3dB/m, temperature trigger 57℃
- Fire Suppression Agent: Heptafluoropropane; Low-end single 40L tank; Mid-end dual 70L tanks; High-end four 120L tanks
- Filling Pressure: 1.2MPa (25℃ ambient)
- Extinguishing Concentration: ≤8% volume fraction, residue-free, non-polluting, excellent electrical insulation
- Startup Modes: Low-end automatic only; Mid-end automatic + manual; High-end automatic + manual + remote electrical startup
6.7 Intelligent Monitoring Host Technical Specifications
- Processor: Low-end 4-core, Mid-end 6-core, High-end 8-core
- Memory & Storage: Low-end 4G RAM / 500G HDD; Mid-end 8G RAM / 1T HDD; High-end 16G RAM / 2T HDD
- Supported Input Channels: Low-end 16 sensor/camera channels; Mid-end 32 channels; High-end 64 channels
- Local Display: Low-end 7-inch LCD touch screen; Mid-end 10-inch LCD touch screen; High-end 15-inch LCD touch screen
- Remote Management: Low-end Web only; Mid-end Web + Mobile APP; High-end Web + APP + WeChat Mini Program
- Alarm Notification: Low-end local audible & visual alarm only; Mid-end local alarm + SMS/WeChat push; High-end local alarm + SMS/WeChat/Email multi-channel push
- AI Functions: Low-end none; Mid-end basic real-time monitoring; High-end AI energy efficiency optimization + abnormal fault analysis
7 Full Product Application Scope
7.1 Container Enclosure Application Scope
- Field Scenarios: Mining areas, oil fields, communication base stations, border outposts, meteorological stations, PV/wind power plants, providing dust-proof, waterproof, seismic independent machine room environments
- Emergency Disaster Backup: Rapid deployment of computing power post earthquakes, floods, fires to support emergency command, data recovery and communication guarantee
- Edge Computing: Smart cities, smart industrial parks, smart transportation, industrial internet edge nodes for low-latency local computing support
- Branch Offices: Small & medium enterprises, chain organizations, bank branches, school campuses for standardized fast machine room construction
- Data Center Capacity Expansion: Modular expansion of large data centers with on-demand computing capacity and shortened construction cycles
- Special Industries: Military, aerospace, scientific research, medical image storage, film post-production requiring high-security, high-stability computing infrastructure
7.2 IT Cabinet Application Scope
- Server Deployment: Rack servers, blade servers, high-density servers for all power density tiers
- Network Equipment Deployment: Switches, routers, firewalls, optical modules, patch panels for structured cabling and network management
- Storage Equipment Deployment: Disk arrays, storage servers, NAS, DAS for data storage & backup
- Supporting Machine Room Equipment: UPS, PDU, monitoring hosts, fire suppression units, indoor air conditioner integrated deployment
- Industrial Control: Industrial servers, PLCs, industrial controllers, sensors for on-site industrial data collection & control
7.3 Power Supply & Distribution System Application Scope
- Machine Room Power Supply: Delivers stable uninterrupted power to IT, cooling and monitoring equipment to achieve 99.995% system availability
- Emergency Power Backup: Seamless UPS & battery switchover during mains outages to prevent data loss and support emergency processing
- Redundant Power Supply: Mid/high-end 1+1/2N redundant design ensures zero downtime from single-point failures for high-reliability scenarios
- Precision Power Distribution: Hierarchical power distribution, real-time energy monitoring, leakage & lightning protection for safe, easy operation & maintenance
- New Energy Supporting: Supporting power supply for PV, wind power and energy storage power stations
7.4 Cooling System Application Scope
- Machine Room Heat Dissipation: Precisely cools IT equipment to maintain standard temperature & humidity ranges (18–24℃, 40%–60%RH) for stable equipment operation
- High-Density Heat Dissipation: Mid/high-end models support 5–18kW per cabinet high-density loads; hot & cold aisle containment boosts cooling efficiency by over 30%
- Extreme Environment Heat Dissipation: Dust-proof & waterproof design for high-temperature, high-humidity, sandy field operating conditions
- Energy Saving & Consumption Reduction: High-end water cooling + free cooling mode cuts energy consumption by over 30% under low load with PUE as low as 1.15
7.5 Fire Protection & Security System Application Scope
- Fire Prevention & Suppression: Early hazard detection, rapid residue-free fire suppression to protect IT equipment and data integrity for clean machine room environments
- Intrusion Prevention: Multi-layer access control, video surveillance and infrared detection to block unauthorized physical access
- Environmental Monitoring: Real-time tracking of temperature, humidity, water leakage and smoke with abnormal alarms to avoid potential failures in advance
- Unattended Site Adaptation: Remote live view, access control and alarm notifications for sites without on-site staff
7.6 Intelligent Monitoring System Application Scope
- Centralized Control: Unified management of power supply, cooling, fire protection, security and environmental sensors with centralized data display & analysis
- Remote Operation & Maintenance: Web/APP remote equipment status viewing, parameter configuration and fault troubleshooting to cut on-site labor costs
- Early Warning Alerts: Real-time abnormal event notifications to enable rapid response and reduce downtime risks
- Energy Consumption Management: Statistics of power & cooling energy usage with AI automatic parameter adjustment to lower PUE and achieve green low-carbon operation
8 Full Product Advantages
8.1 Container Enclosure Advantages
- Full Factory Prefabrication: Complete production, assembly and testing in factories; finished product delivered to site, only requiring hoisting, power & network connection, cutting deployment cycles by 70% vs traditional machine rooms
- Ultra-Fast Delivery: Standard models in stock for 7–15 day delivery; customized models delivered within 30–45 days to meet urgent project demands
- Superior Environmental Adaptability: IP55 protection, Grade 8–10 seismic resistance, -40℃ to +55℃ operating temperature, suitable for mining, field and emergency scenarios
- Modular Expandability: Single unit standalone operation or multi-unit stacking/splicing for on-demand capacity expansion, precise investment without resource waste
- Customization Support: Customizable dimensions, appearance, LOGO and internal layout for special site and brand requirements
- OEM/ODM Manufacturing: Custom production per client drawings & requirements with strict confidentiality agreements
- Long Service Life: 25-year design lifespan, corrosion & aging resistant materials with low long-term maintenance costs
8.2 IT Cabinet Advantages
- High Load-Bearing Capacity: Cold-rolled steel construction supporting 800–1500kg loads for stable high-density equipment deployment without deformation
- Efficient Heat Dissipation: Mesh door + silent fan design for smooth airflow, lowering equipment operating temperature and extending service life
- Modular Design: Standardized detachable blanking panels, cable managers and trays adaptable to various equipment sizes
- Safe & Reliable: Tempered glass lockable doors prevent equipment theft; anti-static design protects sensitive electronic hardware
- Full Series Coverage: Low/mid/high tier options matching low to high density scenarios with cost-effective pricing
8.3 Power Supply & Distribution System Advantages
- Ultra-Stable Output: Online double-conversion UPS with harmonic distortion ≤3% to shield IT hardware from grid voltage fluctuations
- Long Backup Duration: Maintenance-free lead-acid batteries deliver 30–90min full-load backup time for emergency processing or generator switchover
- Redundant Reliability: Mid/high-end 1+1/2N parallel redundancy enables automatic failover with zero service interruption, achieving 99.999% availability
- Intelligent Monitoring: Real-time current, voltage and power monitoring on power distribution cabinets & PDUs for easy energy statistics and maintenance
- Multi-Layer Safety Protection: Overload, overvoltage, short circuit, lightning and leakage protection to eliminate electrical hazards
8.4 Cooling System Advantages
- Precise Temperature Control: ±0.3℃~±1℃ temperature accuracy to stabilize machine room ambient conditions for consistent equipment performance
- High Energy Efficiency: Hot & cold aisle containment eliminates air mixing, boosting cooling efficiency by 30%; high-end water-cooled models reach PUE ≤1.15
- Redundant Cooling Assurance: Mid/high-end N+1/2N redundancy prevents overheating shutdowns if single air conditioner fails
- Low Noise Operation: Silent fan design limits noise to 45–55dB for quiet operating environments
- Harsh Environment Compatibility: Dust & waterproof construction for stable operation in high-temperature, high-humidity and sandy field sites
8.5 Fire Protection & Security System Advantages
- Rapid Fire Suppression: Heptafluoropropane gas extinguishes fires instantly with no residue, pollution or electrical conduction damage to servers and storage
- Early Hazard Warning: Multi-type detectors identify fire risks at early stages for timely intervention and minimal loss
- Full-Coverage Security: Multi-layer access control, video surveillance and door magnetic sensors eliminate blind monitoring zones covering entrances, internal areas and cable trenches
- Unattended Operation Compatibility: Remote monitoring and multi-channel alarms reduce on-site manpower costs significantly
8.6 Intelligent Monitoring System Advantages
- All-in-One Centralized Control: Single platform managing all subsystems with unified data visualization, storage and analysis for streamlined maintenance
- Remote O&M Support: Web & mobile APP access for real-time equipment status review, parameter tuning and remote fault diagnosis
- AI Intelligent Optimization: High-end AI energy efficiency module automatically adjusts air conditioner & UPS operating parameters to cut power consumption and optimize PUE
- Timely Multi-Channel Alerts: Instant SMS/WeChat/Email notifications for abnormal events to accelerate troubleshooting and reduce downtime
- Full Series Compatibility: Low/mid/high tier monitoring hosts matching all container machine room configurations with flexible cost options
8.7 Brand & Service Advantages
- Ample Spot Inventory: Full range of standard models in stock for fast shipment and shortened lead times
- Flexible Customization: End-to-end customization from enclosure structure to internal equipment for unique client requirements
- Professional OEM/ODM Experience: Strict quality control and on-time delivery for private label manufacturing
- Strict Confidentiality: Non-disclosure agreements to fully protect client intellectual property and project data
- Fully Transparent Technical Data: Complete public specifications, detailed operation manuals and third-party test reports available upon request
9 Product Tender Control Parameters (Marked with *)
9.1 Container Enclosure Tender Control Parameters
*1. Cabinet Dimensions: Standard 20ft (6058×2438×2896mm) / 40ft (12192×2438×2896mm), non-standard customization supported *2. Protection Rating: IP55, fully dust-proof and resistant to low-pressure water spray *3. Seismic Resistance Grade: ≥Grade 8, withstands Zone 3 seismic activity *4. Operating Ambient Temperature: -40℃ ~ +55℃ for extreme environment adaptability *5. Thermal Insulation Thickness: ≥50mm for low/mid-end versions, ≥80mm for high-end versions, thermal conductivity ≤0.03W/(m·K) *6. Design Service Life: ≥25 years
9.2 IT Cabinet Tender Control Parameters
*1. Cabinet Dimensions: 600×(1000/1100/1200)×(2000/2200)mm, 42U/48U standard 19-inch rack *2. Load-Bearing Capacity: ≥800kg (low-end), ≥1200kg (mid-end), ≥1500kg (high-end) *3. Steel Plate Thickness: ≥1.5mm cold-rolled steel (low-end), ≥2.0mm (mid-end), ≥2.5mm (high-end) *4. Cooling Fan Configuration: ≥2 silent fans (low-end), ≥4 (mid-end), ≥6 (high-end)
9.3 UPS Uninterruptible Power Supply Tender Control Parameters
*1. Rated Capacity: ≥10KVA/9KW (low-end), ≥20KVA/18KW (mid-end), ≥40KVA/36KW (high-end) *2. Operation Mode: Online double conversion topology *3. Energy Efficiency: ≥92% (low-end), ≥95% (mid-end), ≥97% (high-end) *4. Full-Load Backup Time: ≥30min (low-end), ≥60min (mid-end), ≥90min (high-end) *5. Redundancy Support: 1+1 parallel redundancy (mid-end), 2N parallel redundancy (high-end)
9.4 Battery Pack Tender Control Parameters
*1. Nominal Voltage: 12V per cell *2. Rated Capacity: ≥100AH (low-end), ≥150AH (mid-end), ≥200AH (high-end) *3. Battery Type: Valve-regulated sealed lead-acid maintenance-free *4. Charge-Discharge Cycle Life: ≥500 cycles (low-end), ≥800 cycles (mid-end), ≥1000 cycles (high-end) at 100% depth of discharge
9.5 In-Row Precision Air Conditioner Tender Control Parameters
*1. Cooling Capacity: ≥12KW (low-end), ≥25KW (mid-end), ≥40KW (high-end) *2. Temperature Control Accuracy: ≤±1℃ (low-end), ≤±0.5℃ (mid-end), ≤±0.3℃ (high-end) *3. Operating Noise: ≤55dB (low-end), ≤50dB (mid-end), ≤45dB (high-end) *4. Redundancy Mode Support: N+1 redundant operation (mid-end), 2N redundant operation (high-end) *5. Cooling Type: Air-cooled (low/mid-end), water-cooled (high-end)
9.6 Fire Suppression System Tender Control Parameters
*1. Fire Suppression Agent: Heptafluoropropane, extinguishing concentration ≤8%, residue-free, non-polluting, excellent insulation *2. Detector Type: Photoelectric smoke only (low-end), combined smoke & temperature (mid-end), triple smoke/temperature/CO composite (high-end) *3. Startup Modes: Automatic + manual dual startup (mid-end), automatic + manual + remote electrical startup (high-end)
9.7 Intelligent Monitoring Host Tender Control Parameters
*1. Supported Input Channels: ≥16 channels (low-end), ≥32 channels (mid-end), ≥64 channels (high-end) *2. Remote Management Access: Web only (low-end), Web + Mobile APP (mid-end), Web + APP + WeChat Mini Program (high-end) *3. Alarm Notification Channels: Local audible & visual alarm + SMS/WeChat push (mid-end), local alarm + SMS/WeChat/Email multi-channel push (high-end)
10 Full Product Solution Packages
10.1 Container Machine Room Solution for Mining & Oil Field Sites
Pain Points: No supporting infrastructure on field sites, high temperature & heavy sand dust, unstable power supply, rapid deployment requirements, unattended remote operation Configuration Scheme: 20ft/40ft standard enclosure (IP55 + Grade 9 seismic resistance) + mid-end redundant power supply (1+1 UPS) + air-cooled N+1 redundant precision air conditioners + heptafluoropropane fire suppression + APP-enabled intelligent monitoring host + HD cameras + access control Core Advantages: Dust-proof, waterproof & seismic resistant, stable operation under high-temperature sandy conditions, redundant power & cooling for zero downtime, remote unattended operation, full deployment within 15 days Implementation Steps: Site leveling → Foundation reinforcement → Container hoisting & positioning → Mains power & network connection → Full system commissioning → Online operation
10.2 Emergency Disaster Backup Container Machine Room Solution
Pain Points: Ultra-fast post-disaster deployment, high seismic & waterproof performance, short delivery cycle, high-reliability disaster recovery computing power, full data security protection Configuration Scheme: 20ft high-end enclosure (IP55 + Grade 10 seismic resistance) + high-end 2N redundant power supply + 2N redundant air-cooled precision air conditioners + dual-tank heptafluoropropane fire suppression + AI intelligent monitoring host + facial recognition access control + multi-channel HD cameras Core Advantages: Deliverable within 7 days for emergency activation, superior seismic & waterproof anti-damage performance, full redundancy for 99.999% uptime, encrypted data backup, fast remote troubleshooting Implementation Steps: Disaster site location survey → Rapid temporary foundation construction → Container hoisting → Emergency power connection → Network activation → System commissioning → Disaster backup system startup
10.3 Edge Computing Container Machine Room Solution for Smart Cities
Pain Points: Low-latency local edge computing, high-density rack power, compact footprint, energy efficiency for urban edge nodes Configuration Scheme: 20ft mid-end enclosure (IP55, 50mm insulation) + 6 mid-end IT cabinets + 1+1 redundant mid-end UPS + N+1 redundant water-cooled precision air conditioners + full hot & cold aisle containment + APP remote monitoring host Core Advantages: 12kW per cabinet high-density computing power, ultra-low latency local processing, PUE ≤1.2 energy-saving design, compact rapid deployment for smart city edge nodes Implementation Steps: Edge station site selection → Foundation construction → Container hoisting → Mains power access → Network debugging → Computing hardware deployment → Online service launch
10.4 Branch Office Container Machine Room Solution for Small & Medium Enterprises
Pain Points: Limited budget, compact footprint, standardized basic machine room, simple operation & maintenance, stable daily office performance Configuration Scheme: 20ft low-end enclosure (IP55, Grade 8 seismic resistance) + 5 low-end IT cabinets + standalone low-end UPS + N-config air-cooled precision air conditioners + basic fire suppression + Web-only intelligent monitoring host Core Advantages: Cost-effective budget-friendly solution, standardized unified deployment, simple easy maintenance, stable performance for enterprise branch office data & network services Implementation Steps: Branch site layout planning → Foundation treatment → Container hoisting → Power & network connection → Hardware installation & commissioning → Service launch
10.5 Modular Expansion Solution for Large-Scale Data Centers
Pain Points: Modular capacity expansion, ultra-high density computing, full redundant high availability, low PUE energy efficiency, zero impact on existing production systems during construction Configuration Scheme: 40ft high-end enclosure (IP55, Grade 10 seismic resistance) + 15 high-end anti-static IT cabinets + 2N redundant high-end UPS system + 2N redundant water-cooled precision air conditioners + motorized full hot & cold aisle containment + AI energy optimization dual monitoring hosts Core Advantages: 18kW per cabinet ultra-high density AI & big data computing, full redundancy for uninterrupted operation, PUE as low as 1.15 for significant energy savings, modular expansion without disrupting existing data center business, short construction cycle Implementation Steps: Data center expansion area layout planning → Foundation reinforcement → Multi-container splicing & hoisting → Mains power grid connection → Core network interconnection → Full system commissioning → New computing capacity online launch
11 Project Application Cases
11.1 40ft High-Density Container Machine Room Project for Northwest Open-Pit Coal Mine
Project Background: Large coal mine in Northwest China with no traditional on-site machine room, requiring 15 high-density server cabinets to support mine data collection, real-time monitoring and dispatching systems. Site conditions include summer temperatures up to 50℃, heavy sand dust and unstable grid power. Configuration Scheme: KITOZER-40FT-H high-end enclosure + 15 sets KITOZER-C6048-H high-density cabinets + 4×KITOZER-UPS-40KVA-H 2N redundant UPS + 6×KITOZER-AC-40KW-H 2N redundant water-cooled air conditioners + 4×KITOZER-FM-120L-H fire suppression units + 2×KITOZER-MON-H flagship monitoring hosts Project Outcomes: Full deployment completed in 12 days, cutting construction time by 80% vs conventional brick-and-mortar machine rooms; IP55 enclosure fully withstands extreme high temperature and sand dust with zero unplanned outages year-round; 2N redundant power & cooling eliminates downtime risks; AI monitoring optimizes operational parameters to stabilize PUE at 1.18, saving 300,000 kWh electricity annually.
11.2 20ft Edge Computing Container Machine Room Project for Southern Smart City
Project Background: Smart city construction in Southern China requiring distributed edge computing nodes to process smart traffic, public security and environmental monitoring data, with strict requirements for low latency, compact footprint and energy efficiency. Configuration Scheme: KITOZER-20FT-M mid-end enclosure + 6×KITOZER-C6042-M medium-density cabinets + 2×KITOZER-UPS-20KVA-M 1+1 redundant UPS + 3×KITOZER-AC-25KW-M N+1 redundant air-cooled air conditioners + full hot & cold aisle containment assembly + 1×KITOZER-MON-M APP-enabled monitoring host Project Outcomes: Fully deployed and operational within 8 days to support real-time edge data processing; 12kW per cabinet medium density meets computing load demands; hot & cold aisle containment maintains PUE ≤1.2 with obvious energy savings; remote unattended monitoring cuts daily O&M labor costs by 50%.
11.3 20ft Disaster Backup Container Machine Room Project for Local Emergency Management Bureau
Project Background: Municipal emergency management bureau required dedicated disaster backup computing infrastructure to maintain uninterrupted emergency command and data backup during earthquakes, floods and other natural disasters, with mandatory fast deployment, seismic & waterproof performance and ultra-high reliability. Configuration Scheme: KITOZER-20FT-H high-end enclosure + 5×KITOZER-C6042-H high-density cabinets + 2×KITOZER-UPS-20KVA-H 2N redundant UPS + 2×KITOZER-AC-25KW-H 2N redundant air-cooled air conditioners + 2×KITOZER-FM-70L-M dual-tank fire suppression units + 1×KITOZER-MON-H AI monitoring host Project Outcomes: Complete deployment finished within 5 days for instant emergency activation post-disaster; Grade 10 seismic resistance and IP55 protection withstand extreme natural disasters; full redundant architecture guarantees zero interruption of emergency command systems; encrypted local data backup ensures complete emergency data security.
11.4 Branch Office Container Machine Room Project for National Chain Retail Enterprise
Project Background: National retail chain opened 10 new regional branches, each requiring a small standardized machine room for store management, transaction data transmission and on-site video surveillance, with tight budget constraints and simple centralized O&M requirements. Configuration Scheme: KITOZER-20FT-L low-end enclosure + 5×KITOZER-C6042-L basic IT cabinets + 1×KITOZER-UPS-10KVA-L standalone UPS + 2×KITOZER-AC-12KW-L air-cooled air conditioners + basic fire suppression kit + 1×KITOZER-MON-L Web monitoring host Project Outcomes: Single branch deployment completed within 7 days with simultaneous rollout across all 10 stores; unified standardized configuration simplifies group-level centralized operation & maintenance; total project investment reduced by 40% compared with traditional on-site built machine rooms; long-term stable operation with equipment failure rate below 0.1%.
11.5 Modular Capacity Expansion Project for Large-Scale Internet Data Center
Project Background: Major domestic internet data center faced surging AI & big data computing demand requiring modular expansion with 15 high-density cabinets, with strict constraints to avoid disrupting existing live production systems, support ultra-high power density and maintain low energy consumption. Configuration Scheme: KITOZER-40FT-H high-end enclosure + 15×KITOZER-C6048-H anti-static high-density cabinets + 4×KITOZER-UPS-40KVA-H 2N redundant UPS + 6×KITOZER-AC-40KW-H 2N redundant water-cooled air conditioners + motorized full hot & cold aisle containment + 2×KITOZER-MON-H flagship AI monitoring hosts Project Outcomes: Entire expansion module installed and commissioned within 15 days without any impact on original data center services; 18kW per cabinet high-density rack design fully meets AI training and big data analysis computing loads; optimized cooling system achieves PUE as low as 1.15, saving over 1,000,000 kWh electricity every year; full redundant architecture eliminates single-point failure risks for post-expansion stable operation.
12 Equipment Faults & Maintenance Guidelines
12.1 Container Enclosure Common Faults & Maintenance
Common Faults
- Water leakage: Aged sealing strips, cracked weld seams, incomplete sealing of cable entry ports
- Poor thermal insulation: Moisture-damaged or broken insulation layers leading to internal temperature & humidity out of range
- Rust & structural deformation: Long-term outdoor UV exposure & rain corrosion causing steel plate rust and load-bearing frame bending
- Door malfunction: Damaged locks, rusted hinges, incomplete sealing gaps
Maintenance Schedule
- Daily Inspection: Check enclosure surface for rust, deformation or damage; test door opening & closing smoothness and sealing integrity; inspect cable port sealing; clear roof standing water & debris
- Monthly Maintenance: Clean surface dust & oil stains; apply anti-rust paint annually; replace aged sealing strips; repair cracked weld seams; inspect insulation for water damage and breakages
- Quarterly Maintenance: Tighten loose load-bearing frame bolts; inspect lightning grounding connection tightness, ensure ground resistance ≤4Ω
- Annual Overhaul: Full structural, sealing, insulation and lightning protection inspection with formal test report; replace aging fittings and repair damaged components
12.2 IT Cabinet Common Faults & Maintenance
Common Faults
- Deformed cabinet doors & stiff operation: Loose hinges, damaged connecting pieces, bent sheet metal
- Overheating & poor heat dissipation: Broken cooling fans, blocked mesh vents, obstructed air channels
- Load-bearing deformation: Overweight equipment or irregular installation bending cabinet beams & columns
- Damaged accessories: Broken cable managers, deformed trays, missing blanking panels
Maintenance Schedule
- Daily Inspection: Check door smoothness & deformation; listen for abnormal fan noise; monitor internal cabinet temperature; verify equipment mounting stability
- Monthly Maintenance: Clean dust from mesh vents and cooling fans to maintain unobstructed airflow; tighten cabinet bolts and door hinges; replace damaged accessories; organize internal cabling
- Quarterly Maintenance: Inspect load-bearing components for bending and reinforce as required; test anti-static grounding continuity
- Annual Overhaul: Full cabinet structural, heat dissipation and accessory inspection with test report; replace aging fans and repair deformed metal parts
12.3 Power Supply & Distribution System Common Faults & Maintenance
Common Faults
- UPS alarms & power cutoffs: Degraded batteries, abnormal mains voltage, overload, internal UPS failure
- Battery swelling & leakage: Overcharging, deep discharge, aging, high ambient temperature
- Distribution cabinet tripping & short circuits: Aging cables, load short circuits, leakage, damaged circuit breakers
- PDU no output & overheating: Electrical overload, poor contact, failed lightning arresters
Maintenance Schedule
- Daily Inspection: Monitor UPS operating status, indicator lights and alarm codes; check battery voltage, temperature and swelling/leakage signs; verify power cabinet & PDU meter readings; inspect cables for overheating or insulation damage
- Monthly Maintenance: Record UPS, battery and power distribution operational parameters; wipe equipment dust to maintain ventilation; tighten loose terminal lugs; replace failed lightning arresters
- Quarterly Maintenance: Test individual battery cell voltage & internal resistance, replace degraded batteries; verify UPS mains/battery automatic switchover and full backup duration; test circuit breaker and leakage protection functionality
- Annual Overhaul: Full power system inspection with test report; calibrate power meters & sensors; replace aging cables and fittings; conduct full load and redundant switchover testing
12.4 Cooling System Common Faults & Maintenance
Common Faults
- Air conditioner no cooling or insufficient cooling: Failed outdoor unit, refrigerant leakage, blocked filter screens, broken fans
- Uncontrolled temperature/humidity & internal condensation: AC failure, blocked air channels, incomplete aisle containment, failed dehumidification
- Outdoor unit abnormal vibration & noise: Damaged fans, loose fixing bolts, bent heat exchange fins
- Internal water leakage: Blocked drain pipes, damaged condensate pans, uneven installation tilt
Maintenance Schedule
- Daily Inspection: Monitor AC operating status, temperature & humidity readings; check outdoor unit running noise and vibration; inspect for water leakage and internal condensation; verify hot/cold aisle sealing integrity
- Monthly Maintenance: Clean internal filter screens, evaporators and outdoor heat exchange fins; tighten outdoor unit fixing bolts; test refrigerant pressure and replenish leaked coolant; clear drain pipe blockages
- Quarterly Maintenance: Test cooling, dehumidification and humidification functions; inspect fan motors and capacitors; clear air channel obstructions and air leakage gaps
- Annual Overhaul: Full cooling system inspection with test report; replace aging fans, motors and capacitors; calibrate temperature & humidity sensors; conduct system pressure and redundant switchover testing
12.5 Fire Protection & Security System Common Faults & Maintenance
Common Faults
- False/missed detector alarms: Dust coverage, aging hardware, sensitivity drift, broken signal cables
- Fire suppression unit failure to activate: Insufficient tank pressure, broken startup wiring, damaged solenoid valves
- Access control failure & unreadable cards: Damaged card readers, faulty controllers, broken communication lines
- Camera no image or blurry footage: Dirty lenses, failed infrared LEDs, power supply or cable faults
Maintenance Schedule
- Daily Inspection: Check detector indicator status; verify fire suppression tank pressure; test access control and camera live feed; inspect cable integrity for damage or loose connections
- Monthly Maintenance: Wipe dust from detector and camera lenses; test detector alarm sensitivity; verify access card reading function; check fire suppression tank pressure and refill as required
- Quarterly Maintenance: Test fire suppression startup and full system linkage functions; inspect access control & camera power and wiring; replace aging detectors and card readers
- Annual Overhaul: Full fire & security system inspection with test report; replace aged detectors, fire suppression accessories and cameras; complete full fire linkage and security functional testing
12.6 Intelligent Monitoring System Common Faults & Maintenance
Common Faults
- Monitoring host crash & lagging performance: Insufficient memory, full storage disk, system faults, poor internal heat dissipation
- Abnormal/missing sensor data: Damaged sensors, broken wiring, communication disconnection
- Failed remote access & APP connection errors: Network faults, server malfunctions, incorrect account permissions
- Missing or false alarm notifications: Incorrect alarm configuration, faulty sensors, system software bugs
Maintenance Schedule
- Daily Inspection: Monitor host CPU, memory and storage utilization; verify real-time sensor data accuracy; test network connectivity and remote access; review alarm logs and push records
- Monthly Maintenance: Wipe dust from monitoring host and sensors; back up system configuration and historical data; inspect communication cables and ports; optimize system performance and clear junk files
- Quarterly Maintenance: Calibrate sensor precision; test remote access and alarm push functions; analyze system logs to identify hidden anomalies; upgrade system firmware and monitoring software
- Annual Overhaul: Full intelligent monitoring system inspection with test report; replace aging sensors and hardware; conduct system performance and redundant switchover testing
13 Factory Capacity & After-Sales Service
13.1 Factory Strength
KITOZER brand’s manufacturing base specializes in R&D, production, sales and service of standard prefabricated container machine rooms and intelligent data center equipment with 20 years of industry experience, ranking among China’s leading manufacturers of modular data center infrastructure.
- Production Scale: 50,000㎡ factory compound with standardized production workshops, precision metal processing equipment, automated assembly lines and professional testing laboratories; annual output capacity reaches 2,000 standard container machine rooms and 50,000 IT cabinets to fulfill large-batch order demands
- R&D Capability: R&D team accounts for 30% of total staff with multiple invention and utility model patents, continuously innovating container enclosure, power, cooling and monitoring technologies to maintain industry-leading product performance
- Quality Control System: Fully compliant with ISO9001 Quality Management, ISO14001 Environmental Management and ISO45001 Occupational Health & Safety Management Systems; full-process quality inspection covering raw material procurement, machining, assembly and factory testing with 100% product pass rate; certified by CE, FCC, CCC and other global authoritative standards
- Stable Supply Chain: Long-term strategic partnerships with top raw material suppliers including Baosteel, Delta and Schneider to guarantee consistent material quality, stable supply and controlled production costs for competitive pricing
- Delivery Capability: Full stock of standard models for 7–15 day fast delivery; customized models delivered within 30–45 days; dedicated logistics team provides full shipment tracking to ensure safe, on-time product arrival
13.2 After-Sales Service
KITOZER adheres to the “Customer First, Service Priority” philosophy and has built a full-lifecycle, 24/7 comprehensive after-sales service system delivering one-stop support covering customized solution design, manufacturing, installation commissioning, operation training and fault repair.
1. Warranty Service
- Whole Machine Warranty: 3-year full warranty for complete container machine room systems; 5-year warranty for core equipment including UPS, batteries, precision air conditioners and monitoring hosts; lifetime paid maintenance available post-warranty
- Warranty Coverage: All failures caused by manufacturing defects receive free repair, component replacement, labor and travel cost coverage during the warranty period
- Extended Warranty: Optional 5–10 year extended warranty contracts available upon client request for long-term stable operation guarantees
2. Installation & Commissioning Service
- Professional Certified Engineers: Fully licensed on-site engineering team with rich cross-scenario deployment experience
- Free On-Site Commissioning: Engineers conduct door-to-door installation, equipment alignment and system debugging after product delivery, guiding client coordination to ensure one-time acceptance without rework
- Operation Training Post-Delivery: On-site hands-on training for client O&M staff covering power on/off procedures, parameter configuration, daily inspection and basic fault troubleshooting for independent routine operation
3. Regular Operation & Maintenance Service
- 7×24 Hour Technical Hotline: Round-the-clock phone, online chat and remote desktop support for consultation and fault reporting with instant response
- Remote Troubleshooting: Direct remote access to equipment for parameter adjustment, fault diagnosis and firmware upgrades to eliminate on-site dispatch costs and reduce downtime
- Quarterly Free On-Site Inspection: Mandatory quarterly site visits during warranty period for full system performance testing, hidden fault identification and formal inspection reports with optimization recommendations
- Professional O&M Training: Regular online and offline technical training courses hosted by industry experts and senior engineers covering equipment maintenance, fault resolution and cutting-edge industry technologies to upgrade client technical capabilities
4. Fault Repair Service
- Rapid Response Mechanism: 1-hour initial response post fault notification; remote troubleshooting first; on-site engineer dispatch within 24–48 hours for domestic sites if remote resolution fails
- National Spare Parts Warehouses: Full stock of core replacement components across regional warehouses to enable fast part swapping and minimize equipment downtime
- Post-Repair Warranty: All completed repairs carry a 3-month secondary warranty for the same fault with free rework if issues recur
5. Customized Value-Added Services
- Free Custom Solution Design: Tailored full system solutions based on client site layout, computing power demand and budget, complete with construction drawings and detailed technical specifications & configuration lists
- Full-Range Product Customization: Customizable enclosure dimensions, exterior appearance, LOGO, internal layout and equipment configuration to match unique special project requirements
- OEM/ODM Manufacturing: Private label manufacturing service with strict non-disclosure agreements, full compliance with client design drawings and guaranteed quality & delivery schedules
14 Conclusion
As the core form of modular data centers, standard prefabricated container machine rooms deliver unparalleled strengths including factory prefabrication, ultra-fast deployment, superior environmental adaptability, modular expandability, energy efficiency and intelligent unattended operation. They have become the preferred digital infrastructure for mining field sites, emergency disaster backup, edge computing, enterprise branch offices and large data center capacity expansion.
KITOZER standard prefabricated container machine rooms fully comply with international and domestic industry standards, with a complete low/mid/high product portfolio matching all project scales, scenarios and budget ranges. Every component from the enclosure shell to internal power, cooling, fire protection, security and monitoring subsystems adopts premium raw materials, advanced manufacturing processes and rigorous multi-stage quality control to guarantee stable, energy-efficient and long-lifetime operation.
Moving forward, KITOZER will continue deepening its focus on modular data center infrastructure, increasing R&D investment to continuously optimize product performance, upgrade quality standards and refine the full-cycle service system. We aim to deliver more advanced technology, superior products and professional all-round services to support digital transformation across all industries, maximize client value and jointly build an ecosystem of efficient, green and intelligent digital infrastructure.
15 Search Keywords & SEO Tag System
15.1 Core Primary Keywords (High Traffic Core Terms)
Standard prefabricated container machine room, containerized data center, modular container machine room, prefabricated container machine room, all-in-one container machine room
15.2 High-Conversion Long-Tail Keywords (Precise Lead Generation)
20ft standard prefabricated container machine room, 40ft high-density container machine room, KITOZER prefabricated container machine room, mining field container machine room, emergency disaster backup container machine room, edge computing container machine room, factory prefabricated container machine room, waterproof dustproof container machine room, all-in-one container data center
15.3 Industry General Traffic Keywords (Cross-Industry Coverage)
Modular data center, prefabricated data center, outdoor all-in-one machine room, edge data center, emergency communication machine room, industrial all-in-one