Table of Contents
Toggle1. Cover / Document Information
– Document Title: Swimming Pool Water Quality Online Monitoring System Technical Design Solution
– Prepared by: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Date: August 2026
– Version: V1.0
– Project Type: Technical design solution for Swimming Pool Water Quality Online Monitoring System
2. Table of Contents Structure
1. Company Introduction
2. Project Overview
3. User Requirement Analysis
4. Overall Design Description
5. Detailed System Design and Product Technical Parameters
6. Project Quotation and Configuration List
7. Core Solution Advantages
8. Technical Q&A
9. Construction Schedule Plan
10. Construction Organization Plan
11. After-Sales Service System
12. Operation and Maintenance Training Plan
13. Typical Project Cases
14. SEO Optimization System and Website Backend Configuration
15. Contact Information
3. Company Introduction
3.1 Company Development Overview
Founded in 2002, Guangzhou Lain Intelligent System Development Co., Ltd. is a high-tech enterprise dedicated to the computer room construction and intelligent protection field for more than two decades, integrating R&D, production, sales, engineering implementation and after-sales service. The company focuses on innovative breakthroughs in electromagnetic shielding technology, modular computer room technology and computer room environmental monitoring technology, and has grown into a source manufacturer with core competitiveness in the domestic computer room construction field.
After more than twenty years of industry accumulation, the company has built a large-scale production and manufacturing base equipped with advanced CNC sheet metal processing equipment, automated spraying production lines and professional testing laboratories, with an annual production capacity of hundreds of sets of shielding computer rooms, integrated cabinets and micro-module products. The company’s service network covers all provinces and cities across the country, providing thousands of computer room construction and renovation services for customers in government, military, scientific research, finance and enterprise fields.
3.2 Core Business System
The company’s core business revolves around the full-lifecycle construction of computer rooms, forming four major product and service systems:
– Computer room EPC general contracting service: one-stop services from solution design, manufacturing, on-site construction to commissioning and acceptance, covering shielding computer rooms, IDC data rooms, modular computer rooms, container computer rooms and other types;
– Core equipment R&D and production: independently produces KITOZER brand series products, including shielding cabinets, shielding desks, consoles, integrated data cabinets, micro-module cold aisle cabinets, outdoor rainproof cabinets, etc., supporting non-standard customization;
– Computer room environmental monitoring system: provides full-element monitoring solutions for temperature and humidity, water leakage, access control, video, fire protection, UPS and power distribution, realizing intelligent and unattended O&M;
– Shielding and security protection products: shielding rooms, shielding doors and windows, anechoic chambers and related auxiliary materials, widely used in confidential, military and scientific research fields.
3.3 Brand and Qualification Honors
The core brand KITOZER (Pioneer) focuses on computer room equipment and shielding products, positioned as an “efficient, green, innovative and safe” solution provider. Products have passed multiple authoritative tests and comply with national and industry standards. The company holds multiple utility model patents and software copyrights, has been awarded high-tech enterprise qualification, and follows the ISO9001 quality management standard.
3.4 Core Competitive Advantages
1. Source production, controllable quality: own production base and professional processing equipment; core products independently produced with full-process quality control, providing more cost-effective solutions without intermediate links;
2. Customized design, matching needs: tailor-made solutions per site conditions, technical requirements, configuration and budget, with multiple design options provided free of charge;
3. Professional team, rich experience: a professional technical team of engineers and project managers with more than ten years of industry experience;
4. Quality after-sales, full guarantee: a 7×24 professional online service system with dedicated project follow-up from early coordination to later O&M.
4. Project Background and Objectives
4.1 Project Background
Pool water quality directly affects swimmer health and safety — pH, free chlorine, ORP and turbidity must stay within national standards. Traditional manual testing and dosing are labor-intensive, imprecise and prone to missed supervision (especially at night and off-peak), causing unstable water quality, chemical overuse and compliance risks. An online monitoring and automatic dosing system — 24h real-time sensing, intelligent PID dosing and platform management — is the essential upgrade for swimming pools, hotels, sports centers and water parks.
4.2 Project Objectives
Real-time online monitoring of pH, ORP, free chlorine, temperature (and optional turbidity) with CJ/T 244-2016 standard compliance; automatic precise dosing via PID control keeping water quality stably within range; 24h unattended operation reducing labor and chemical cost; complete data records, reports and alarm notification for regulatory compliance; expandable modular architecture for multi-pool central management and future parameters/equipment integration.
4.3 Project Scope
Water quality sensing subsystem (sensors + sampling flow cell + booster pump), automatic dosing subsystem (2 dosing pumps + level sensors), data transmission/network subsystem (gateway, switch, optional 4G), monitoring platform (industrial PC + software), safety/alarm subsystem (sound/light + remote push), installation, calibration, training and after-sales.
5. User Requirement Analysis
5.1 Core Functional Requirements
Continuous pH/ORP/free-chlorine/temperature monitoring with temperature compensation; automatic pH-adjustment and disinfection dosing; PID precise control with dosing limits and dry-run protection; local touchscreen display with trends; alarms (quality limits, low chemical level, sensor fault, communication loss); platform with real-time view, history, reports, alarm management and permissions.
5.2 Performance Requirements
Measurement accuracy: pH +-0.02, ORP +-5mV, chlorine +-0.02mg/L or 5% F.S., temperature +-0.15 degC; refresh 1s; control response meeting pool dynamics; system 24h continuous operation.
5.3 O&M Requirements
Simple daily maintenance (weekly chemical check, monthly electrode cleaning, 1-2 month pH calibration, semi-annual chlorine membrane/electrolyte replacement); low consumable cost; remote monitoring; easy fault location.
5.4 Compliance Requirements
Control per CJ/T 244-2016 and GB 9667; data records exportable for health inspection; optional interface to regulatory platforms; CPA/CE/ISO9001 certifications.
6. Design Principles and Applicable Standards
6.1 Design Principles
Reliability first: industrial-grade components; corrosion-resistant wetted parts for chlorinated water; moisture/anti-corrosion electrical design; multi-layer safety protection. Advanced: constant-voltage chlorine detection, PID control, IoT and cloud platform technologies — current for 5-8 years. Practical: Chinese visual interface, simple operation for ordinary pool staff. Expandable: modular hardware/software — new parameters, dosing circuits, pools and cloud functions. Safe and compliant: leakage/overload/short protection, dosing upper-limit protection, encrypted transmission, national pool hygiene and electrical standards. Economical: optimized configuration and long-life low-consumable devices — low lifecycle cost.
6.2 Applicable Standards
CJ/T 244-2016 (pool water quality), GB 9667 (swimming place hygiene), GB 50057-2010 (lightning), GB 50174-2017 (electronic information system rooms), GB 4943.1-2022 (IT equipment safety), GB/T 17626 (EMC level 3), environmental monitoring instrument quality assurance regulations, ISO 7027 (turbidity).
7. System Architecture and Working Principle
7.1 Five-Layer Architecture
Perception layer: sensors (pH composite, ORP, constant-voltage free chlorine, PT100, optional turbidity) mounted in a transparent acrylic flow cell on the sampling branch — converting water parameters to 4-20mA/RS485 signals. Transport layer: shielded cables (RVSP, up to 1000-1200m) sensor-to-controller; industrial gateway (Modbus RTU->TCP) to LAN; optional 4G wireless. Control layer: multi-parameter main controller (KITOZER-YC-ZK01) — filtering, calibration, computation, PID control driving dosing pumps, alarm logic, local independent operation. Platform layer: local workstation or cloud with management software — storage, visualization, statistics, reports, alarms, users. Application layer: local large screen, PC client, Web, mobile mini-program.
7.2 Working Principle
Sampling: a bypass branch from the circulation return main (after filtration, before disinfection) delivers water via valve and booster pump (10-20L/min) into the flow cell — bottom-in/top-out, stable flow over electrodes, overflow/drain back to the loop (closed circuit, no waste). Detection: pH glass-membrane potential, ORP platinum electrode, free chlorine by constant-voltage three-electrode method (no reagent), PT100 temperature compensation, optional 90° scatter turbidity. Control: the controller compares values with setpoints and runs PID — dynamically computing dosing pump frequency; below lower limit increases dosing, near target reduces, at target stops — smooth stable regulation. Alarms: out-of-limit, low chemical level, sensor fault, communication loss trigger local sound/light (>=110dB) and platform push. Data: controller uploads to the platform for storage, statistics, reports and remote settings.
7.3 Water Quality Control Standards (CJ/T 244-2016)
pH 7.0-7.8 (best 7.2-7.6, alarm 7.0/7.8); free chlorine 0.3-1.0mg/L (best 0.5-0.8, alarm 0.3/1.0); ORP >=650mV (best 700-750); temperature (heated pools) 26-28 degC (best 27, alarm 24/30); turbidity <=1NTU (best <=0.5). Child/baby pools use higher chlorine standards per local health requirements.
8. Detailed Technical Design
8.1 Sensing Subsystem
Sampling line: takeoff from circulation return main between filter and disinfection; UPVC DN25; stop valve, Y-filter (protecting flow cell and electrodes), flow regulating valve; flow 10-20L/min. Flow cell (KITOZER-YC-LT01): transparent food-grade acrylic, bottom-in/top-out with flow-stabilizing structure (no turbulence/bubbles); 5 electrode ports (4 standard + 1 spare), PG13.5 threads; overflow top, drain bottom; DN25 in/out, DN20 drain; <=0.6MPa; 0-60 degC; D80x350mm; wall bracket. Sensors: pH composite (0-14, +-0.02, T90<=10s, low-resistance chlorine-resistant glass, Ag/AgCl double-junction, built-in PT1000, PPS body, PG13.5, IP68, life >=2 years); ORP ( -1000~+1000mV, +-5mV, 99.99% platinum, double-junction, IP68, life >=3 years); constant-voltage free chlorine (0-5mg/L, +-0.02mg/L or 5%, T90<=30s, gold cathode/silver anode, selective membrane, no reagent, IP68, body >=2 years, membrane 6-12 months, electrolyte 3-6 months); PT100 ( -20~+80 degC, +-0.15 degC, 4-20mA, 304 stainless, IP68); turbidity (0-10NTU, +-2% F.S. or +-0.05NTU, 90° scatter ISO 7027, 860nm IR, 316L + sapphire optics, IP68, optional).
8.2 Dosing Subsystem
Two independent circuits: pH circuit — dosing pump KITOZER-PUMP-PH01 (0-10L/h, 0.7MPa, 30W, 4-20mA control) for acid/alkali adjuster (pH above upper limit -> dose down); disinfection circuit — KITOZER-PUMP-CL01 (0-15L/h, 0.7MPa, 35W) for sodium hypochlorite (chlorine below lower limit -> dose up). Each circuit: check valve, injection valve, filter, suction tube; chemical drums with photoelectric level sensors (KITOZER-SENS-YW01, DC12-24V, NPN/dry contact, <=1ms, +-1mm, PC probe, IP68) for low-level alarm. Pumps: electromagnetic diaphragm, PVC/PVDF head, PTFE diaphragm, ceramic ball valves, F-class, IP65, <=50dB, stroke + frequency dual adjustment, overpressure relief, self-priming exhaust. Booster pump (KITOZER-PUMP-ZY01): magnetic-drive centrifugal UPVC, 30L/min, 8m head, AC220V 60W, shaftless zero-leak, <=40dB, IP54. Control logic: PID closed loop with field-tunable parameters; dosing upper-limit protection (no over-dose even on sensor fault); dry-run lockout (no water in flow cell -> pumps locked).
8.3 Transmission and Network Subsystem
Field bus: RVSP 2×1.0mm2 shielded twisted pair (aluminum foil + copper braid >=85%), analog to 1000m, digital to 1200m, in PVC/galvanized conduit with shield earthing. LAN: industrial RS485-to-Ethernet gateway (KITOZER-GW-01, ARM, 15kV ESD, Modbus RTU->TCP, 300-115200bps, DC9-36V <=2W, DIN, -40~+85 degC, EMC level 4); 5-port gigabit industrial switch (KITOZER-SW-05, 10Gbps, DC12-48V <=5W, DIN, -40~+85 degC); gigabit LAN to workstation. Wireless (optional): 4G full-network module (MQTT/Modbus TCP/transparent, RS485, DC9-36V, standby <1W, auto reconnect, encrypted).
8.4 Platform Subsystem
Workstation: commercial industrial host + 23.8″ monitor (i5, 8GB, 256GB SSD). Software KITOZER-YC-V1.0: C/S architecture (multi-client), SQL Server 2016+; process-flow interface; digital/gauge/trend displays; multi-pool single-page monitoring; history query with multi-parameter overlay, zoom/pan/detail; Excel export; real-time popup alarms with sound, three levels (general/important/urgent), records with confirm/remark/handling; auto daily/weekly/monthly/yearly reports (average/max/min/std/attainment) with Excel/PDF and custom templates; remote range/threshold/PID/calibration settings with operation logs; multi-level users (admin/operator/guest) with full audit; refresh 1s; >=5 years storage; >=20,000h MTBF; up to 10 clients.
8.5 Safety and Alarm Subsystem
Electrical: RCD + breakers, reliable earthing, IP65+ outdoor/damp equipment, surge protection on power/signal ports (lightning induction). Water quality: dosing speed/total upper limits (sensor fault or wrong settings cannot over-dose); pH/chlorine high-low dual alarms. Local: industrial sound/light alarm (AC220V, >=110dB, red flash 1Hz, IP65, -30~+70 degC). Remote: SMS, WeChat push, email via platform.
8.6 Main Controller (KITOZER-YC-ZK01)
Wall-mount; ARM Cortex-M4 168MHz; embedded RTOS (start <3s); 7″ TFT touch 800×480 + physical keys; Chinese/English; 320x240x120mm ~3.2kg; ABS with IP65 panel; 4 x 4-20mA AI (250 ohm, +-0.1% F.S.); 2 x RS485 (Modbus RTU 9600-115200); 8 opto-isolated DI; 2 x 4-20mA AO (<=500 ohm, +-0.2%); 6 relay DO (AC250V 5A / DC30V 5A); RS232 + Ethernet; accuracy +-0.5% F.S.; refresh 1/s; PID/on-off/time-proportion control modes with independent P/I/D; upper/lower, deviation and fault alarms with hysteresis; 8GB Flash (3+ years minute-level history); 1-60min record interval; parameter retention and auto-restart on power return; AC220V +-15% <=12W; insulation >=100M ohm; withstand AC1500V/1min; surge protection; GB/T 17626 level 3; 0-55 degC; panel IP65 / body IP54; multi-point calibration with reminders; real-time and 1h/24h curves; data export; two-level passwords; self-diagnosis; manual/auto one-key switch.
9. Recommended Configuration and Preliminary Budget
9.1 Configuration Summary
Main control unit: 1 controller, 1 flow cell, 1 sound/light alarm. Sensors: pH, ORP, constant-voltage chlorine, PT100 (turbidity optional). Dosing: pH pump (10L/h), chlorine pump (15L/h), 2 level sensors, booster pump, UPVC sampling kit. Network/center: gateway, 5-port switch, workstation, software (lifetime license), optional 4G module. Cables/accessories: RVSP 80m, RVV 100m, Cat5e 60m, 304 stainless IP65 distribution box, electrode guards/joints, terminals/labels/waterproof joints, conduit/clips/ties/anchors. Services: installation/commissioning, calibration solutions, training, 1-year warranty, optional annual maintenance.
9.2 Budget Notes
Standard single-pool configuration; multi-pool and custom options quoted per configuration; tax-inclusive in RMB (CNY) only; 10-day total schedule (site work ~4 days); 12-month warranty with 2 free inspections; lifetime support.
10. Technical Specifications
10.1 System Specification Summary
| Item | Specification |
|---|---|
| Standards | pH 7.0-7.8 (best 7.2-7.6); free chlorine 0.3-1.0mg/L (best 0.5-0.8); ORP >=650mV (best 700-750); temp 26-28 degC; turbidity <=1NTU per CJ/T 244-2016, GB 9667 |
| Controller | KITOZER-YC-ZK01; ARM M4 168MHz; 7″ touch 800×480; 4AI (4-20mA +-0.1%) + 2AO + 6DO (AC250V 5A) + 8DI + 2RS485 + Ethernet; PID/on-off/time-proportion; 8GB (3+ yrs); AC220V <=12W; IP65 panel; GB/T 17626 level 3; manual/auto switch |
| Sensors | pH 0-14 +-0.02 (life >=2yr); ORP +-1000mV +-5mV (>=3yr); constant-voltage chlorine 0-5mg/L +-0.02 or 5% (no reagent, membrane 6-12mo, electrolyte 3-6mo); PT100 +-0.15 degC; turbidity 0-10NTU ISO7027 90° scatter; all PG13.5, IP68, chlorine-resistant |
| Dosing | pH pump 0-10L/h 0.7MPa 30W; chlorine pump 0-15L/h 0.7MPa 35W; electromagnetic diaphragm PVC/PTFE/ceramic, 4-20mA control, IP65, <=50dB; 2 photoelectric level sensors (IP68, <=1ms); booster pump 30L/min 8m 60W magnetic zero-leak <=40dB |
| Sampling | UPVC DN25 branch (filter->disinfection point); Y-filter, valves; acrylic flow cell 5 ports PG13.5, bottom-in/top-out, overflow + drain; 10-20L/min closed loop |
| Network | RVSP shielded 1000m/1200m; gateway ARM 15kV ESD Modbus RTU->TCP DC9-36V -40~+85 degC; 5-port gigabit switch DC12-48V; optional 4G full-network MQTT auto-reconnect |
| Platform | C/S + SQL Server; refresh 1s; >=5yr storage; reports day/week/month/year with Excel/PDF; three-level alarms; multi-level users + audit; up to 10 clients; MTBF >=20,000h |
| Alarm/safety | Local sound/light >=110dB IP65; dosing speed/total upper limits; dry-run lockout; pH/chlorine dual high-low alarms; RCD + surge protection; SMS/WeChat/email push |
| Delivery | 10 days (survey 1, stocking 3, site 4, trial/acceptance 2); 12-month warranty, 2 free inspections; 7×24 support, 1h response, 24h/48h on-site; training ~3h with assessment |
10.2 Standards Compliance
CJ/T 244-2016, GB 9667, GB 50057, GB 50174, GB 4943.1, GB/T 17626 (EMC level 3), ISO 7027 (turbidity), CPA metering certification, CE, ISO9001; optional regulatory platform data interface (Modbus/MQTT).
11. Key Advantages and Customer Value
11.1 Advanced and Accurate
Industrial electrochemical sensors with constant-voltage chlorine detection — far more accurate, stable and durable than consumer-grade devices; automatic temperature compensation and digital filtering eliminate interference — reliable data for quality control.
11.2 Intelligent Stable Control
PID closed-loop control — an order of magnitude better than on/off dosing; stable in-range water quality; dynamic dosing saves chemicals and reduces disinfection by-products — better swimmer comfort.
11.3 Unattended and Cost-Saving
24h automatic monitoring and dosing — no manual testing/dosing; reduced labor and human error; quality maintained even at night — higher operational efficiency.
11.4 Multi-Layer Safety
Electrical (leakage/overload/surge), control (dosing limits, dry-run lockout, fault alarms) and water-quality (dual high-low alarms) protection — no safety accidents.
11.5 Data Management and Compliance
Full-time data records with standard reports — traceable and exportable for health inspections; data analysis optimizes dosing and evaluates equipment.
11.6 Flexible Expansion
Modular — parameters, dosing circuits, multi-pool central monitoring; future turbidity/Dissolved Oxygen/total chlorine, and integration with circulation pumps, filters, heaters and ozone equipment — full automation.
11.7 Professional Service
Full-process service (design, supply, installation, training, after-sales); source factory with better price, quality and support.
12. Technical Q&A (50+ Items)
12.1 Principles and Selection
Q1: What parameters are monitored?
A: Standard pH, ORP, free chlorine and temperature — the four key pool indicators; optional turbidity, DO, total chlorine, conductivity.
Q2: What does ORP mean? Relation to chlorine?
A: ORP (mV) reflects the water’s oxidation/disinfection capacity; >=650mV indicates sufficient germicidal ability; positively correlated with chlorine but also affected by pH/temperature — combined monitoring gives a fuller picture.
Q3: Chlorine measurement principle? Reagent needed?
A: Constant-voltage (polarographic) three-electrode method — no reagent, no consumable cost; selective membrane passes chlorine molecules; current proportional to concentration.
Q4: Does sampling waste water?
A: No — closed-loop return: 10-15L/min bypass returns to the circulation system.
Q5: What pool sizes fit?
A: All sizes from private/club pools to standard competition pools and water parks; dosing pump sizing varies with volume/flow; controller and sensors universal.
Q6: Indoor vs outdoor differences?
A: Same core; outdoor needs higher protection/UV shielding; outdoor chlorine consumption logic optimized.
Q7: Why PID over on/off control?
A: PID continuously adjusts dosing by deviation and rate — smooth stable control, no oscillation, chemical savings.
Q8: How is temperature compensated?
A: PT100 measures water temperature; controller applies automatic compensation to pH/chlorine readings.
12.2 Installation and Commissioning
Q9: Where is the system installed? Space?
A: In the pump room near the circulation line; controller wall-mounted, flow cell wall-mounted, pumps beside chemical drums — ~1-2 m2 of wall space.
Q10: Does installation damage existing piping?
A: No — only a small bypass takeoff on the return main; 1-2 days; minimal impact on operations.
Q11: Environment requirements?
A: Ventilated, no standing water, 0-50 degC; equipment is moisture/chlorine resistant; outdoor — waterproof box and sun protection.
Q12: How long is commissioning? Calibration hard?
A: ~half a day — wiring, calibration with standard solutions via guided on-screen steps; ordinary staff can do it after training.
Q13: What calibration solutions are included?
A: pH 4.01/6.86, ORP and chlorine calibration solutions each set.
Q14: How is the sampling flow set?
A: Regulating valve to 10-20L/min — stable, no bubbles in the flow cell.
12.3 O&M
Q15: Daily maintenance workload?
A: Weekly chemical check; monthly electrode rinse; 1-2 month pH calibration; semi-annual chlorine membrane/electrolyte change — tens of minutes monthly.
Q16: Sensor life and replacement cost?
A: pH ~2 years, ORP ~3 years, chlorine body ~2 years (membrane/electrolyte consumables 6-12 months) — low cost vs labor and chemical savings.
Q17: Annual chlorine consumable cost?
A: Membrane + electrolyte set a few hundred RMB per 6-12 months — far below manual testing costs.
Q18: Winter closure storage?
A: Remove electrodes, clean, cap pH with storage solution, dry chlorine electrode, store cool and dry; reinstall and calibrate next season.
Q19: Power consumption?
A: ~100W average (controller 12W + intermittent pumps + booster) — ~70 kWh/month.
Q20: What if chemicals run out?
A: Level sensors alarm at low level; dosing stops for that circuit; refill clears the alarm.
12.4 Troubleshooting
Q21: Inaccurate readings?
A: Check flow/bubbles; clean electrodes; recalibrate; replace end-of-life electrodes.
Q22: Dosing pump not working?
A: Check power/switch; auto mode and thresholds; suction line blockage and chemical level; purge pump head air.
Q23: Alarm handling?
A: Quality alarm — check dosing equipment or load change, manual assist if needed, auto-clears on recovery; low-level — refill; fault — per prompt, contact support.
Q24: Power failure behavior?
A: All parameters retained; auto-restart on power return with previous settings — no manual reconfiguration.
Q25: PC down affects control?
A: No — monitoring and auto-dosing run independently on the field controller; PC is only for viewing/settings.
Q26: Communication failure?
A: Check gateway power/network, wiring, address/baud; data cached locally and resumes.
Q27: Why does the booster pump run continuously?
A: It maintains continuous sample flow for real-time sensing; magnetic drive is maintenance-free; flow is small.
Q28: Free chlorine drifts — causes?
A: Membrane fouling (clean/replace), electrolyte depletion, sensor aging, pH/temperature shifts — calibrate monthly.
12.5 Compliance and Qualifications
Q29: Does it meet national pool standards?
A: Yes — control per CJ/T 244-2016 and GB 9667; data supports quality management.
Q30: Are data accepted by health inspection?
A: Online monitoring is an auxiliary management tool; laboratory sampling remains the official method; our data correlates well — daily compliance passes inspections; many regions encourage online systems.
Q31: Certifications?
A: CPA metering approval, CE, ISO9001.
Q32: Regulatory platform interface?
A: Modbus/MQTT per local authority requirements — real-time upload.
Q33: Is the system suitable for baby pools?
A: Yes — higher chlorine setpoints per local requirements.
12.6 Service
Q34: Warranty?
A: 12 months whole system; electrodes with quality faults replaced free; consumables (membrane, electrolyte, calibration solutions) excluded.
Q35: Response time?
A: 7×24 hotline; 1h response (remote first); 24h urban / 48h suburban on-site; backup equipment for core faults.
Q36: Inspections?
A: 2 free on-site inspections in warranty (half-year and one-year): status, electrode care, performance tests, parameter optimization, hidden risks — with reports.
Q37: Spares?
A: Stocked sensors, pumps, boards; 5+ years post-phase-out supply; preferential pricing.
Q38: Training?
A: ~3h at delivery: theory, on-screen operations, maintenance, calibration, fault handling; assessment with retraining; manuals, cards, PPT, fault list delivered.
Q39: What documentation is delivered?
A: Operation manual, maintenance handbook, quick cards, wiring diagrams, test reports, acceptance records.
Q40: Annual maintenance plans?
A: Optional all-inclusive service (regular maintenance, consumables, fault response); third-party water testing; upgrade discounts for existing customers.
Q41: Can it manage multiple pools?
A: Yes — platform supports multi-pool single-page monitoring with per-pool independent control.
Q42: How is data exported?
A: Excel/PDF reports and raw history export via the platform.
Q43: Why choose KITOZER/Lain?
A: Source factory, CPA/CE certified, proven hotel/sports-center/water-park deployments, full lifecycle service.
Q44: What are the platform access modes?
A: Local large screen, PC client, Web browser and mobile mini-program.
Q45: Can it integrate with building automation?
A: Yes — Modbus/MQTT interfaces to BAS/venue smart systems.
Q46: Is the interface in Chinese?
A: Chinese default with English switchable.
Q47: What is the refresh rate?
A: 1 second for data; controller stores minute-level history for 3+ years.
Q48: How is overdosing prevented?
A: Dosing speed/total upper limits, dry-run lockout, PID convergence and dual alarms — no over-dose even on sensor fault.
Q49: What if the flow cell is empty?
A: Dry-run lockout stops dosing pumps until water flow resumes.
Q50: What makes it cost-effective?
A: Labor savings (e.g. ~60k RMB/year in a case), 15% chemical savings, low consumables, 24h compliance assurance and lifetime support.
13. Construction Schedule
13.1 Schedule (Single Standard System, 10 Days)
| Stage | No. | Work | Duration | Responsible | Note |
|---|---|---|---|---|---|
| Preparation | 1 | Site survey (position, pipe interface, power points) | 1d | Project engineer | After contract |
| 2 | Equipment/material procurement and stocking | 3d | Procurement | Standard in stock | |
| 3 | Tools/accessories and personnel arrangement | 1d | Crew lead | ||
| Site | 4 | Piping: sampling line, valves, filters, flow cell fixing | 1d | Plumber + crew | |
| 5 | Equipment: controller, dosing pumps, box, alarm fixing | 0.5d | Electrician + crew | ||
| 6 | Cabling: signal/power/network laying in conduits | 1d | Electrician | ||
| 7 | Wiring: device/box/earthing connections | 0.5d | Electrician | ||
| Commissioning | 8 | Power-on check, single-device tests | 0.5d | Debug engineer | |
| 9 | Sensor calibration, parameter setting | 0.5d | Debug engineer | ||
| 10 | Auto-control logic and dosing linkage tests | 1d | Debug engineer | ||
| 11 | Alarm function and data upload tests | 0.5d | Debug engineer | ||
| Acceptance | 12 | Trial run, water quality stability observation | 1d | Engineer + customer | |
| 13 | Operation/maintenance training | 0.5d | Engineer | ||
| 14 | Acceptance sign-off and documentation | 0.5d | PM + customer |
Total 10 days (site work ~4 days excluding stocking); multi-system or complex sites adjusted; can run in parallel with pool renovation.
14. Construction Organization and Quality/Safety Measures
14.1 Organization
PM (1): overall coordination, progress, customer liaison, quality responsibility. Technical engineer (1): scheme, disclosure, commissioning, support. Crew lead (1): site management, dispatch, safety/quality. Electrician (1): wiring, device connection, power-on. Plumber (1): piping, valves, flow cell. Helper (1): transport, fixing, cabling.
14.2 Preparation
Technical: review drawings/scheme; disclosure; confirm water/power/pipe conditions; detailed plan; drawings, wiring diagrams, manuals. Materials: full check (model/qty/appearance); cables, conduits, hardware; tools (drill, cutter, multimeter, crimpers, wrenches); PPE (helmet, insulating gloves, goggles, harness). Site: entry procedures; temporary power/water; cleared area; finished-product protection.
14.3 Core Processes
Positioning: mark controller, flow cell, box, pumps, alarm positions and conduit routes — level and neat. Piping: tap the return main; install Y-filter, regulating/stop valves; run UPVC sampling line to the flow cell; return line to the loop; pressure test 0.3MPa/30min no drop. Equipment fixing: wall brackets and mounts per marks; stainless box with rails/terminals/power module; pumps beside drums; sensors/alarm at specified positions. Cabling: PVC conduits with clamps; signal/power/network with line numbers; adequate slack; neat dressing, strong/weak separated. Wiring: per diagrams; firm tinned terminations; earthing <=4 ohm; full check before power-on. Commissioning: staged energization; sensor zero/slope calibration; thresholds/control/alarm parameters; manual mode device tests; auto mode with PID tuning; alarm drills (limit, low level); data upload and platform tests; 24h trial with parameter optimization.
14.4 Quality Control
Pipe standards (level runs, firm, no leakage, correct valve orientation, support spacing); electrical standards (correct cable selection, firm connections, strong/weak separation >=30cm, earthing <=4 ohm, insulation test); installation standards (accurate, firm, level, clear labels, sealing); self-check per process, daily patrols, mid-term and final inspections with records.
14.5 Safety and Civilized Construction
Helmets, harnesses for high work; certified electricians with two-person live work; RCD-protected temporary power; safe tool use; no smoking, hazardous materials stored properly; power off and site check after daily work; tidy materials and daily cleanup; low noise around operations; finished-product protection; sealed conduit ends; parameter passwords after commissioning.
15. After-Sales Service
15.1 Warranty Commitment
12-month whole-system warranty from acceptance; free repair/parts for non-human faults; consumables (membrane, electrolyte, calibration solutions) excluded; electrodes with quality faults replaced free in warranty.
15.2 Response
7×24 hotline; 1h response (remote first); 24h urban / 48h suburban on-site (remote areas negotiated); backup equipment for core faults to minimize downtime.
15.3 Periodic Inspection
2 free on-site inspections in warranty (half-year and one-year): device status, sensor cleaning, electrode performance, piping check, parameter optimization, cleaning, hidden-risk removal — formal reports.
15.4 Spares
Full spares stock (sensors, pumps, boards); preferential post-warranty pricing; >=5 years supply after phase-out.
15.5 Lifetime Support
Lifetime technical consultation; free software patches; preferential expansion/retrofit services; customer service archives with continuous O&M advice.
15.6 Value-Added
Annual maintenance agreements (full-service maintenance, consumables, fault response); third-party water testing assistance; exclusive discounts for returning customers.
16. Training Plan
16.1 Training Objectives and Audience
Training objectives: through systematic training, enable management personnel to fully understand the system structure, working principles and performance characteristics, master daily operation methods and inspection/maintenance essentials, identify common faults and handle simple problems, ensuring safe, stable and long-term operation.
Training audience: management and O&M personnel designated by the client, recommended 2-3 persons with basic electrical and equipment knowledge.
16.2 Tiered Training Content System
Level 1: Basic operation training (1 day)
– Basic principles: system concepts, structure composition, performance indicators;
– Daily operation standards: correct operation of equipment, control and safety systems;
– Daily inspection contents: daily/weekly/monthly check items;
– Safety precautions: usage prohibitions and emergency handling procedures.
Level 2: Maintenance training (1 day)
– Detailed structure of each subsystem and working principles;
– Daily maintenance methods: cleaning, fastening checks, routine care;
– Common fault identification and simple handling;
– Emergency handling procedures for power failure, fire and equipment faults.
Level 3: Advanced management training (as needed)
– Performance influencing factors and how to avoid degradation;
– Upgrade and expansion knowledge and specification requirements;
– Relevant national standards interpretation.
16.3 Training Methods and Schedule
– Methods: combination of “theory explanation + on-site practice + Q&A interaction”;
– Schedule: training arranged at the completion acceptance stage, synchronized with handover, 2 days of intensive training total; time flexibly adjustable; a free repeat training session is provided for newly assigned personnel.
16.4 Training Assessment and Documentation Delivery
– Assessment: theory written test plus practical operation; training qualification certificates issued upon passing; supplementary training for those who fail;
– Documentation delivery: complete O&M documentation, including operation and maintenance manual, equipment manuals and certificates, completion drawings and hidden work records, test reports and after-sales service contact card, all bound into volumes.
17. Anonymous Typical Project Scenarios
All project scenarios below are anonymous, generalized examples provided for reference only. No real customer names, addresses or identifiable details are disclosed.
17.1 High-End Residential Community Club Pool
Background. A 500 m3 indoor heated pool with ~100 daily visitors relied on manual testing/dosing — unstable quality, heavy workload and frequent chlorine non-compliance.
Solution. Online monitoring system (pH/ORP/chlorine/temperature) with two automatic dosing circuits (pH adjuster + sodium hypochlorite) and a local workstation.
Results. pH stable 7.2-7.6 and chlorine 0.4-0.8mg/L; health inspection passed first time; one dedicated water-quality staff eliminated (~60k RMB/year saved); chemical use down ~15%; standardized records raised property quality.
17.2 Sports Center Standard Competition Pool
Background. A municipal 2,500 m3 standard competition pool for professional training and events demanded competition-grade water quality; the old system was imprecise.
Solution. Two monitoring units (both ends) with pH/ORP/chlorine/turbidity/temperature, four dosing circuits, central control room platform integrated with the venue smart system.
Results. Water met international swim-standard requirements (turbidity <=0.5NTU, crystal clear); stable disinfection eliminated swimmers’ eye/skin irritation; central multi-screen monitoring; multiple provincial events hosted with excellent water assurance.
17.3 Five-Star Hotel Heated Pool
Background. A business hotel’s indoor heated pool demanded high water quality and guest experience with strict cost control.
Solution. Premium monitoring system with imported chlorine electrode, intelligent PID control and cloud platform — managers view water quality on mobile phones.
Results. Consistently excellent quality with zero guest complaints; engineering staff skip daily manual checks; precise dosing reduced chlorine smell and improved comfort; 2 years fault-free — adopted for subsequent hotel projects.
17.4 Water Park Project
Background. A large outdoor water park (8,000 m3 across play pools, wave pool and slide pools) faced difficult multi-pool quality management during peak summer traffic.
Solution. 6 zoned online monitoring systems with a central management platform — unified monitoring and independent per-zone automatic dosing.
Results. One operator monitors all pools from the central room; stable compliant quality through peak season with zero hygiene incidents; labor cost down 30%+; robust outdoor weather resistance.
18. SEO Optimization Section
All reference prices in this technical solution are in RMB (CNY) only and are for reference purposes; final quotation is subject to the confirmed configuration.
18.1 Keyword System
– Core keywords: technical design solution, system configuration, technical parameters, construction and O&M services;
– High-conversion long-tail keywords: design solution, configuration list, technical parameters, construction plan, after-sales service;
– Industry traffic keywords: system architecture, applicable standards, technical Q&A, project cases;
– Brand keywords: KITOZER, Guangzhou Lain.
18.2 SEO Tag System
– Title tag: the article title — Guangzhou Lain KITOZER;
– Meta description: Guangzhou Lain professionally provides complete technical design solutions with detailed configuration list, full-system product technical parameters, construction organization plan and after-sales service — source manufacturer customization, compliant performance, third-party testing supported;
– H1 tag: the article title;
– H2 tags: system design and product parameters, construction organization plan, after-sales service and training, engineering cases.
18.3 Internal Link Anchor Text
– Core anchor text: technical design solution, system construction;
– Long-tail anchor text: configuration list, technical parameters, construction plan;
– Related anchor text: shielding cabinet, micro-module cold aisle, integrated computer room, outdoor cabinet.
19. Official Contact Information
– Company Name: Guangzhou Lain Intelligent System Development Co., Ltd.
– Brand: KITOZER (Pioneer)
– Official Website: https://gdlain.com
– Tel: +86 139 2228 9957 (WeChat available), +86 185 2066 8845 (WeChat available)
– Address: No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
For any inquiries about this technical design solution, configuration customization, quotation or construction services, please contact us through the information above. We provide free design consultation and tailored solutions for your specific requirements.