Table of Contents
ToggleStacking Switches Together
Stackable switches (e.g., 24-port + 24-port) link into one logical unit. The stacking cables connect them in a ring, and you manage the stack as one switch. Here’s the cable setup.
Topology: Ring
Switch 1 port 1 -> Switch 2 port 1. Switch 2 port 2 -> Switch 3 port 1. Last switch port 2 -> Switch 1 port 2. This forms a ring. If one cable fails, the ring breaks and traffic flows the other way.
Rules
- Use the manufacturer’s stacking cables (not standard Ethernet).
- Keep stacking cables short (they’re pre-made, 1m).
- Power on the lowest unit first, then the next, then the next.
- The stack master is usually the lowest unit. Don’t change master unless needed.
- Don’t mix switch generations in one stack.
Cable Management
Stacking cables run between the switches (which are stacked 1U apart). They’re short, thick, and stiff. Route them along the side of the rack, not through the cable manager. Label each cable so you know which switch pair it connects.