Table of Contents
Toggle1. Product Overview
1.1 Product Introduction
Traffic signal pole, also known as red light pole, is the dedicated load-bearing structure for urban road traffic signal control systems. It is mainly used to install motor vehicle signal lights, non-motor vehicle signal lights, pedestrian crossing signal lights, direction indicator signal lights, countdown displays and other traffic control equipment. It is the core infrastructure for intersection traffic order management. The product uses high-strength steel plate bending and welding, octagonal cross-section design, overall hot-dip galvanized anti-corrosion, strictly follows national standards for road traffic facilities, with high load-bearing capacity, strong wind resistance, long service life, and standard compliance.
1.2 Product Positioning
Positioned as a professional-grade road traffic facility product, targeting public security traffic management departments, municipal engineering units, traffic construction enterprises, and system integrators, providing national standard compliant traffic signal pole solutions, strictly matching intersection lane count and signal equipment configuration, suitable for urban level crossings, highway crossings, park intersections and other traffic signal control scenarios.
1.3 Core Value
- Compliance load-bearing value: Strictly designed and produced according to national standards, meeting the load-bearing requirements of signal light groups, ensuring stable operation of traffic signal systems.
- Long-term safety value: High-strength structure + dual anti-corrosion, outdoor service life up to 20 years, reducing urban facility maintenance costs.
- Standard acceptance value: Parameters and processes conform to traffic facility specifications, can be accompanied by structural calculation report, ensuring project passes traffic management department acceptance.
- Intensive construction value: Supports integrated installation of signal lights, signs, surveillance equipment, achieving multi-function pole, reducing number of poles at intersections.
1.4 Product Highlights
- Octagonal tapered cross-section design, excellent bending and torsion resistance, suitable for large cantilever heavy-load scenarios.
- Overall hot-dip galvanized + outdoor powder coating, long anti-corrosion life, adaptable to complex outdoor environments.
- Multiple structures: cantilever, column, gantry, covering different lane numbers.
- Can integrate signal lights, traffic signs, electronic police, monitoring and other functions.
- Flange connection for easy installation, equipped with ladder and maintenance access for convenient later maintenance.
2. Product Classification and Composition
2.1 Classification
By structure: Cantilever signal pole, column signal pole, gantry signal pole, attached signal pole.
By cantilever length: 3m, 4m, 5m, 6m, 8m, 10m, 12m, 15m.
By function: Motor vehicle signal pole, pedestrian signal pole, integrated combination pole, multifunctional common pole.
By cross-section: Octagonal signal pole, conical signal pole, square tube signal pole.
2.2 Composition
Traffic signal pole mainly consists of seven major components: main column, horizontal cantilever, flange base, ladder/maintenance access, signal controller installation box, grounding system, and fasteners. The main column is the vertical load-bearing body, mostly octagonal tapered structure; the horizontal cantilever is a horizontally extending arm for hanging signal light groups, length covering corresponding lane count; the flange base is the bottom connection structure, fastened to concrete foundation embedded parts; ladder/maintenance access is for operation and maintenance, poles above 6m generally equipped with ladder; signal controller box is used to place the traffic signal controller; grounding system builds lightning protection grounding; fasteners adopt high-strength galvanized bolts.
3. System Principle
Traffic signal pole is a typical large cantilever beam structure. The self-weight of signal light groups, ice and snow loads, and wind loads on the horizontal cantilever generate bending moment and torque, which are evenly transmitted to the foundation through the octagonal main column. Compared with circular cross-sections, the octagonal cross-section improves bending stiffness by over 20%, with better torsional performance, effectively handling wind vibration and loads under long cantilevers.
Electrically, signal cables enter the lower signal controller box from underground pipe network, are distributed by the signal controller, and then laid along the pole and cantilever through conduit to connect each group of signal lights, realizing signal control transmission. The pole is grounded as a whole, equipped with surge protection devices, forming a comprehensive lightning protection system to ensure electrical safety of signal systems and prevent lightning damage.
4. Specification and Technical Parameters Table
| Parameter Item | Standard Specifications | Customizable Range |
| — | — | — |
| Column height | 6m / 6.5m / 7m / 8m | 4m ~ 12m |
| Cantilever length | 3m / 4m / 5m / 6m / 8m | 2m ~ 15m |
| Column top diameter | 120mm / 140mm / 160mm | 100mm ~ 250mm |
| Column bottom diameter | 220mm / 250mm / 300mm | 180mm ~ 400mm |
| Column wall thickness | 4.0mm / 5.0mm / 6.0mm | 3.0mm ~ 10mm |
| Cantilever specification | Φ114 / Φ140 / Octagonal 165 | Customized cross-section and wall thickness |
| Cantilever wall thickness | 4.0mm / 5.0mm | 3.0mm ~ 8.0mm |
| Main flange size | 400×400 / 500×500 / 600×600mm | 350×350 ~ 800×800mm |
| Flange thickness | 16mm / 20mm / 25mm | 12mm ~ 30mm |
| Anchor bolts | 6-M24 / 8-M24 / 8-M30 | 6~12 pieces, M20~M36 |
| Wind resistance level | Level 12 | Up to Level 14 |
| Design life | 20 years | — |
| Execution standard | GB 50688-2011 | — |
5. Product Configuration List
| No. | Component | Specification | Quantity | Material | Remarks |
| — | — | — | — | — | — |
| 1 | Main column | Custom height | 1 | Q235B carbon steel | Octagonal tapered structure |
| 2 | Horizontal cantilever | Custom length | 1~2 | Q235B carbon steel | Octagonal/circular cross-section |
| 3 | Bottom flange plate | Match column | 1 piece | Q235B thick steel plate | Reinforced with stiffeners |
| 4 | Cantilever connection flange | Match cantilever | 1 set | Q235B steel plate | Bolted connection |
| 5 | Ladder/maintenance access | According to pole height | 1 set | Same as pole material | For poles above 6m |
| 6 | Signal controller box | 600×800×300mm | 1 (optional) | Cold-rolled steel | Outdoor rainproof type |
| 7 | Conduit and clamps | According to number of signal lights | 1 set | Galvanized steel pipe | Internal wiring |
| 8 | Grounding system | Grounding copper bar + bolts | 1 set | Copper + stainless steel | Ground resistance ≤4Ω |
| 9 | Fastener set | Match flange | 1 set | Grade 8.8 high strength | Hot-dip galvanized |
| 10 | Foundation embedded parts | Match flange | 1 set (optional) | Q235 round steel | Anchor bolt group |
6. Core Advantages
6.1 Material Advantage
Adopts national standard Q235B high-quality carbon structural steel, all genuine materials from major steel mills, with material certificates. Plate wall thickness is full size, high-strength bolts adopt grade 8.8 and above, ensuring structural safety margin from material level, meeting high reliability and long service life requirements of traffic facilities.
6.2 Process Advantage
CNC bending forms octagonal cross-section in one pass, with precise angles and tight seams; automatic robot welding for main seams, with full and uniform welds, and flaw detection after welding. Overall hot-dip galvanizing with zinc layer thickness ≥85μm, in accordance with national standards; outdoor polyester electrostatic powder coating with strong adhesion and weather resistance, able to resist outdoor sun and rain for long term.
6.3 Customization Advantage
One-to-one design based on intersection lane count, signal light group number, installation height, and height limit requirements, with cantilever length precisely covering lanes. Supports integration of signal lights, traffic signs, surveillance checkpoints, electronic police, guidance screens and other equipment, achieving multifunctional common pole, saving intersection space and construction costs.
6.4 Cost Advantage
Manufacturer supply with project-confirmed configuration, large-scale production effectively controls costs. Compared with traditional municipal procurement channels, prices are more competitive under the same standard, with shorter delivery times and more flexible services, effectively reducing overall project cost.
6.5 Quality Advantage
Strictly designed and manufactured according to GB 50688 “Code for Design of Urban Road Traffic Facilities”. Each pole undergoes structural verification, plumbness inspection, weld inspection, and zinc layer thickness inspection before leaving factory. Can provide complete documentation such as structural calculation report, test reports, and certificate of conformity, ensuring products meet national standards and pass traffic management department acceptance.
7. Material & Process Analysis
7.1 Material Details
Main material: Q235B carbon structural steel
- Yield strength ≥235MPa, tensile strength 375-500MPa, ample safety margin.
- Excellent welding performance, weld strength can reach over 90% of base metal.
- Good cold bending and stamping performance, suitable for complex forming processes like octagonal bending.
- Mature domestic supply chain, convenient later maintenance and replacement, controllable overall cost.
Fasteners: Grade 8.8 high-strength bolts
- Tensile strength ≥800MPa, yield strength ≥640MPa, excellent mechanical properties.
- Surface hot-dip galvanized for anti-corrosion, no rust in long-term outdoor use.
- Conforms to GB/T 5782 national standard, stable torque coefficient, safe and reliable connection.
7.2 Core Process Description
- CNC Forming: Large-scale CNC bending machine forms octagonal cross-section in one pass, angle error ≤0.5°, straight and beautiful edges.
- Automatic Welding: Robotic automatic welding, main seams adopt submerged arc welding process, large penetration depth, high strength.
- Hot-Dip Galvanizing: Overall pickling and rust removal, then immersed in 450℃ zinc liquid, uniform zinc coating on inner and outer walls, no missed coating.
- Surface Powder Coating: After phosphating treatment, electrostatic spraying of outdoor polyester powder, cured at 200℃, uniform color.
- Precision Assembly: Flanges, cantilevers, and accessories are precisely assembled, hole position tolerance ≤0.5mm, smooth installation and alignment.
- Finished Product Inspection: 3D measurement of form and position tolerances, coating thickness gauge for zinc and powder layers, acceptance one by one.
7.3 Safety Certification
- Conforms to GB 50688-2011 “Code for Design of Urban Road Traffic Facilities”.
- Conforms to GB 50017 “Standard for Design of Steel Structures”.
- Hot-dip galvanizing conforms to GB/T 13912 national standard.
- Company is certified to ISO9001 quality management system.
- Can provide product test reports and structural calculation reports from independent third-party testing institutions.
8. Stock Details
Common specifications are kept in stock to meet emergency needs of small intersections:
- 6m×6m cantilever signal pole (octagonal cross-section, wall thickness 5mm)
- 6.5m×8m cantilever signal pole (octagonal cross-section, wall thickness 6mm)
- 3m pedestrian signal light pole (conical cross-section, wall thickness 3mm)
Standard colors are traffic green and municipal gray. Stock items ship within 3 days; custom items deliver in 15-20 days; large batch orders can be produced and delivered in batches.
9. OEM and Confidentiality
Provides professional OEM processing services for traffic signal poles, supporting customer-supplied drawings or samples, strictly produced according to drawing standards. Can produce under customer brand, using neutral non-marked packaging without reflecting manufacturer information.
A confidentiality agreement is signed for the entire process, and customer technical data and project information are kept strictly confidential. Monthly production capacity exceeds 300 sets of various signal poles, capable of undertaking city-level batch projects. Business support such as cooperating with customers on bidding, issuing qualification documents, and project registration is available.
10. Product Attributes (SKU)
| SKU Code | Product Name | Column Height | Cantilever Length | Wall Thickness | Structure Type |
| — | — | — | — | — | — |
| LA-XH-0603 | Cantilever signal pole | 6.0m | 3.0m | 4.0mm | Octagonal single cantilever |
| LA-XH-0606 | Cantilever signal pole | 6.0m | 6.0m | 5.0mm | Octagonal single cantilever |
| LA-XH-0658 | Cantilever signal pole | 6.5m | 8.0m | 6.0mm | Octagonal single cantilever |
| LA-XH-0710 | Cantilever signal pole | 7.0m | 10.0m | 6.0mm | Octagonal single cantilever |
| LA-XH-030R | Pedestrian signal pole | 3.0m | — | 3.0mm | Cylindrical column |
| LA-XH-060S | Double cantilever signal pole | 6.0m | 6m each direction | 5.0mm | Octagonal double cantilever |
| LA-XH-MJ08 | Gantry signal pole | 5.5m | Span 8m | 6.0mm | Gantry type |
11. Application Scenarios
- Urban intersections: Installation of motor vehicle signal lights at major and minor road crossings.
- Pedestrian crossings: Pedestrian signal lights and crossing request buttons on both sides of zebra lines.
- Highway crossings: Signal control at level crossings of national highways, provincial highways, and urban expressways.
- Industrial parks and factory areas: Traffic light control at internal intersections of large industrial parks and factories.
- Schools and hospitals: Pedestrian crossing signal facilities in front of schools and hospitals.
- Parking lots: Signal light control at entrances/exits of large parking lots and toll stations.
12. Customization Service Details
12.1 Customization Scope
- Dimensions: Column height, cantilever length, pole diameter, wall thickness.
- Structure: Single cantilever / double cantilever / gantry type, flange specifications, ladder configuration.
- Function: Number of signal light groups, traffic sign integration, monitoring equipment integration, signal controller box.
- Appearance: Color, marking, style, decorative elements.
- Special: Height-limit gantry, variable message sign integration, extra-large span gantry, stainless steel material.
12.2 Customization Process
- Requirement communication: Customer provides intersection lane conditions, signal light configuration, height/width limits or drawings.
- Structural design: Engineers perform structural calculations and drawing design, issue force calculation report.
- Scheme confirmation: Provide design plan, calculation report, quotation, and confirm technical requirements with both parties.
- Contract signing: Confirm price, delivery cycle, acceptance criteria, sign formal contract.
- Production: Production according to drawings, with quality inspection at each process.
- Acceptance and delivery: After passing factory inspection, arrange logistics to deliver to project site.
12.3 Customization Advantages
- Professional traffic facility engineers design strictly following national standards.
- Provide official structural calculation report to ensure acceptance by traffic management department.
- Can carry out integrated design of intersection pole integration, achieving multi-function pole, improving intersection aesthetics.
- Customized products enjoy same warranty and after-sales support.
13. Success Cases
13.1 Cooperative Clients
- Signal facility upgrade project of a city public security bureau traffic police detachment.
- Municipal road construction traffic facilities supporting project in a city new district.
- Traffic signal project at level crossings of a national highway reconstruction and expansion project.
- Industrial park road signal system project in an economic development zone.
13.2 Case Highlights
- A city signal renovation project: Supplied 86 cantilever signal poles of various specifications, all passed police department acceptance, stable operation.
- A new district road project: Supplied 120 integrated multifunctional signal poles, integrating signal lights, sign boards, and monitoring equipment, reducing number of poles at intersections.
- A national highway project: Supplied 32 sets of 12-meter large cantilever signal poles, meeting full coverage requirements of six-lane intersections, with wind resistance performance meeting standards.
14. Procurement Service Guarantee
14.1 Supply Guarantee
Own professional traffic facility production line, regular stock of raw materials, and stock of common specifications. Sufficient production capacity, municipal large batch orders can be delivered in batches to ensure project schedule.
14.2 Quality Guarantee
Product overall warranty 3 years, zinc layer warranty 10 years. Include certificate of conformity, material certificate, test report, structural calculation report with delivery; complete documentation ensures passing special acceptance of traffic facilities.
14.3 Logistics Guarantee
Special transport reinforcement plan for large pole components, nationwide logistics delivery, can reach construction site directly. Full responsibility for transportation damage, free replacement, protecting customer interests.
14.4 After-sales Guarantee
Professional technical team responds 7×24 hours, providing installation guidance and technical consulting. Quality issues within warranty are handled free of charge; major issues can be on-site service.
14.5 Invoice Guarantee
Issue proper 13% VAT special invoice, accurate invoicing information, smooth financial coordination.
15. FAQ
Q1: How to determine the cantilever length of a traffic signal pole?
A: The cantilever length needs to cover the outermost motor vehicle lane, generally 0.5-1 meter wider than the total width of one-way lanes. For example, a three-lane one-way road is about 11 meters wide, so the cantilever needs to be 11-12 meters to ensure the signal light is above the center of the lane.
Q2: What are the height requirements for signal pole installation?
A: The lower edge of motor vehicle signal lights should be no less than 5.5 meters above ground. Including the cantilever’s own height, the total column height is generally 6-7 meters; pedestrian signal lights are installed at a height of 2.5-3 meters.
Q3: How large should the foundation for a signal pole be?
A: Determined by cantilever length, pole height, and wind load calculation. A 6-meter cantilever foundation is generally 1200×1200×1500mm, an 8-meter cantilever foundation is generally 1500×1500×1800mm. Soft soil foundation needs to be enlarged and deepened. Our company can provide foundation design drawings.
Q4: Can a common pole integrating signal lights and surveillance be made?
A: Yes. Multifunctional integrated poles are the trend of urban construction, integrating signal lights, sign boards, surveillance, electronic police, street lights, 5G base stations, etc., reducing number of poles at intersections, improving city appearance. Our company can provide integrated design solutions.
Q5: Is there a mandatory national standard for traffic signal poles?
A: Yes. The main standard is GB 50688-2011 “Code for Design of Urban Road Traffic Facilities”, and also needs to comply with relevant national standards for steel structures, galvanizing, etc. Our products are strictly designed and produced according to this standard.
16. Product Fault Handling Methods
| Fault Phenomenon | Possible Cause | Handling Method |
| — | — | — |
| Cantilever sagging or deformation | Excessive wind load, equipment overload, weld fatigue | Immediately stop use, have professionals evaluate structural safety, replace cantilever or reinforce if necessary |
| Pole tilting | Foundation settlement, bolt loosening, vehicle impact | Tighten bolts, inspect foundation settlement, correct tilt or rebuild foundation if exceeded |
| Weld cracking | Weld defects, fatigue stress, overload | Immediately stop use, after professional evaluation, repair weld with reinforcement or replace entirely |
| Coating peeling and rust | Impact damage, zinc layer defects | After rust removal, apply zinc-rich paint + top coat; for large-area rust, return to factory for re-galvanizing and re-coating |
| Poor grounding | Corroded connection wires, loose bolts | Polish and remove rust, reconnect, retest ground resistance to ensure ≤4Ω |
Traffic signal poles are important public traffic facilities. Fault handling must be implemented by professionals, with proper traffic diversion to ensure road traffic safety.
17. Maintenance
- Quarterly inspection: Check pole plumbness, bolt tightness, weld appearance.
- Annual inspection: Comprehensive inspection of structure, grounding resistance, coating condition, tighten all bolts.
- Periodic overhaul: Every 3 years, conduct comprehensive inspection, repair coating, evaluate structural fatigue.
- Inspection after severe weather: Promptly inspect for pole deformation, tilting, equipment loosening after typhoon, heavy rain, snowstorm.
- Cleaning maintenance: Regularly clean pole and signal lamp covers to keep signal display clear.
18. Factory Strength and After-sales Service
Guangzhou Lain Intelligent System Development Co., Ltd. has a professional traffic facility production base, equipped with large-scale CNC bending machines, automatic welding robots, hot-dip galvanizing production line, and powder coating line, with annual production capacity of over 2000 sets of various traffic signal poles. The company has professional structural engineers and can provide one-stop services of design, production, and installation guidance.
After-sales service commitments:
- Overall product warranty 3 years, zinc layer warranty 10 years.
- 7×24 hour technical support hotline.
- Emergency response for quality issues, on-site handling within 48 hours.
- Provide installation guidance and technical training.
- Lifetime maintenance, long-term supply of spare parts.
19. Conclusion
Traffic signal poles are core infrastructure for urban road traffic management, directly related to intersection order and public safety. Guangzhou Lain strictly follows national standards, selects high-quality materials, adopts advanced processes, and provides customers with safe, reliable, and durable traffic signal pole products. We support customized design and OEM processing, and are committed to contributing to urban traffic infrastructure construction.