Wind Farm Modular Data Center | In-row Cooling | Modular UPS | KITOZER

KITOZER Wind Farm Modular Data Center: In-row Cooling, Modular UPS, Cold Aisle Containment

Wind farms in remote mountains, grasslands, or coastal tidal flats need a reliable local room for SCADA, monitoring, communications, and power forecasting — with wide temperature swings, minimal on-site staff, fluctuating grid power, and a short 2–3 month construction window. KITOZER micro-modular data centers integrate racks, cold aisle containment, in-row cooling, UPS, access control, and environmental monitoring into one factory-prefabricated module.

Modular data center cold aisle containment row with 42U racks

1. Product Series

Sub-series Positioning
KITOZER-IC 42U smart server rack (600×1200×2000mm)
KITOZER-CRA 50kW in-row precision AC, horizontal supply
KITOZER-UPS 50–500kVA modular UPS, hot-swappable modules
KITOZER-ADM 1200mm automatic sliding cold aisle door
KITOZER-FW/FL Fixed and tilting skylights for cold aisle containment + fire vent
KITOZER-FACE 7-inch face recognition access terminal
KITOZER-CC Aisle environmental controller (door/skylight/light/sensor)

2. Typical 26-Rack Configuration

26 smart racks, closed cold aisle, 7×50kW in-row AC, 500kVA modular UPS (10×50kVA modules, 9+1 N+1), 160×12V/250Ah batteries, 4×4-tier battery racks. Factory-prefabricated and on-site assembled.

Overhead cable management system for modular data center

3. Key Selection Notes

  • In-row AC: full VFD compressor, 10–100% continuous capacity, N+1 fan redundancy, PTC reheat + wet-mist humidification. Add free-cooling coil for northern wind farms.
  • Modular UPS: set input voltage range to ±25% for fluctuating wind-farm power; include manual maintenance bypass.
  • Cold aisle containment: tilting glass skylights auto-open on fire alarm; sliding doors unlock; lighting switches to emergency mode.
  • Battery backup: ≥30 minutes for safe shutdown and data preservation; avoid over-sizing due to maintenance cost.

Cold aisle containment modular data center rack row

4. Configuration by Wind Farm Size

Farm Size Racks In-row AC UPS Ref. Total (RMB 10k)
Small (<50MW) 8–12 3×50kW 200kVA 120–160
Medium (50–200MW) 16–20 5×50kW 300kVA 200–260
Large (>200MW) 24–30 7×50kW 500kVA 320–380
Offshore substation 12–16 4×50kW (coated) 300kVA 260–320

42U smart server rack in cold aisle

5. Reference Price

26-rack typical configuration: RMB ~¥3,210,000 (~USD 445,800), equipment only. Final pricing subject to site survey and contract.