Table of Contents
2.4G Frequency Band Remote Control Shielding System Technical Design Solution
Integrated Solution for Automated Test Shielding Enclosures and Semi-Shielded Test Systems
Guangzhou Lain Intelligent System Development Co., Ltd.
—
Table of Contents
- Company Profile
- Project Overview
- User Requirements Analysis
- Overall System Design Description
- System Configuration and Quotation List
- Detailed Technical Specifications of System Products
- Core Solution Advantages
- Technical Q&A
- Construction Schedule Plan
- Construction Organization Plan
- After-Sales Service System
- Operation and Maintenance Training Plan
- Representative Engineering Cases
- SEO Optimization and Keyword System
- Website Backend Configuration Information
- Contact Us
—
1. Company Profile
Guangzhou Lain Intelligent System Development Co., Ltd. was founded in 2002 and is a high-tech enterprise specializing in the R&D, production, and sales of electromagnetic shielding equipment, data center infrastructure, and intelligent test equipment. The company’s headquarters and manufacturing base are located in Panyu District, Guangzhou. With over two decades of deep industry experience, the company has accumulated extensive expertise in solution design, custom manufacturing, and project delivery.
The company owns the independent brand KITOZER (开拓者), with products covering electromagnetic shielding rooms, integrated data cabinets, micro-module cold-aisle containment, outdoor telecommunication cabinets, and a full range of RF shielding test equipment. These products are widely applied across consumer electronics, home appliances, telecommunications, medical equipment, aerospace, and scientific research institutions.
Driven by technological innovation, the company holds multiple utility model patents and software copyrights, operates under a strict ISO quality management system, and ensures all products pass third-party authoritative testing with core performance indicators reaching industry-leading levels. Adhering to the business philosophy of “Quality First, Customer Foremost,” the company provides end-to-end services from requirements research, solution design, custom manufacturing, installation and commissioning, to after-sales operations and maintenance. We deliver customized solutions tailored to our customers’ diverse requirements and have served thousands of enterprises both domestically and internationally, earning widespread recognition and praise.
Four Core Competitive Advantages
| Advantage | Description |
| — | — |
| project-confirmed Manufacturing Strength | Our own standardized production facility offers strong flexibility for custom fabrication, controllable delivery lead times, and significant cost advantages. |
| Comprehensive Quality Assurance | Standardized manufacturing processes with full third-party inspection oversight ensure stable product performance and high consistency. |
| Custom Solution Design Service | Our professional engineering team provides multiple design options free of charge, precisely matching customer site conditions and functional requirements. |
| Round-the-Clock After-Sales Support | Support hours and response timing are confirmed on the quotation. |
—
2. Project Overview
2.1 Project Background
With the rapid development of the IoT and smart home industries, the 2.4GHz ISM band has become the mainstream operating frequency for wireless remote controls, Bluetooth devices, and Wi-Fi modules, widely used in bathroom heaters, lighting fixtures, smart locks, small home appliances, and other consumer electronic products. The RF performance, anti-interference capability, and electromagnetic compatibility of wireless remote controls directly determine product quality and user experience. Therefore, rigorous RF performance testing and electromagnetic shielding verification are essential during both product development validation and mass production sampling inspection.
Traditional manual shielding test methods suffer from low efficiency, poor data consistency, unstable shielding effectiveness, and high manual labor intensity, failing to meet the demands of modern mass production and high-precision testing. An automated, high-shielding-effectiveness, batch-test-capable 2.4G remote control shielding test system has become core equipment for electronics manufacturers seeking to enhance product quality and improve production efficiency. As a professional manufacturer and supplier of shielding test solutions, KITOZER provides custom solutions and turnkey projects for clients worldwide, including the USA, Europe, Southeast Asia, the Middle East, and Africa.
2.2 Project Objectives
This project aims to deliver a comprehensive 2.4G frequency band remote control shielding test solution integrating product-level intrinsic shielding guidance + equipment-level enclosure shielding + automated test control + real-time signal monitoring. Specific objectives include:
- Provide remote control PCB and structural shielding design specifications to improve product EMC performance at the source
- Achieve a high shielding effectiveness test environment of ≥100dB in the 2.4G band, isolating external interference and ensuring test accuracy
- Support multi-station batch synchronous testing with pneumatic automated compression, significantly improving test efficiency
- Integrate RF signal regulation and real-time monitoring systems for visualized and traceable test data
- Implement comprehensive safety protection and grounding design to safeguard operators and equipment under test
- Provide flexible expansion capability, adapting to different remote control models through interchangeable tooling fixtures
2.3 Project Scope
This solution covers the full-process delivery of the remote control shielding test system, comprising eight major hardware subsystems — shielding enclosure system, pneumatic drive system, electrical control system, test tooling system, 2.4G RF dedicated components, signal monitoring system, video recording system, and power distribution protection system — along with full-lifecycle services covering design, production, installation, commissioning, training, and after-sales support.
—
3. User Requirements Analysis
3.1 Shielding Performance Requirements
| Parameter | Requirement |
| — | — |
| Operating Frequency Band | 2400MHz – 2483.5MHz (Full 2.4G ISM band) |
| Shielding Effectiveness | Overall enclosure shielding effectiveness ≥100dB @ 2.4GHz |
| Grounding Performance | System grounding resistance ≤4Ω; DC resistance between remote control shield can and PCB ground <0.1Ω |
| Sealing Performance | No significant signal leakage at enclosure joints or feed-through interfaces |
3.2 Test Functional Requirements
| Requirement | Specification |
| — | — |
| Batch Testing | Simultaneously place and test up to 8 remote control units per cycle, suitable for production line batch sampling inspection |
| Test Content | RF transmission power testing, reception sensitivity testing, anti-interference testing, radiated emission pre-compliance testing |
| Signal Regulation | Built-in signal power regulation module: adjustment range -30dBm to +10dBm, attenuation range 0–120dB |
| Data Management | Real-time test data display, automatic storage, report export support, historical data query capability |
3.3 Automation Operation Requirements
- Automatic Lid Open/Close: Pneumatic-driven shielding door with automatic flip operation, dual-hand button activation, and anti-pinch safety protection
- Automatic Compression: Built-in multi-station compression cylinders that automatically press down on test products, ensuring test consistency
- Simple Operation: Integrated operator panel with clear function labeling; ordinary workers can operate after minimal training
3.4 Safety Protection Requirements
- Emergency Stop Protection: Rotating-reset emergency stop button for one-key shutdown in abnormal conditions
- Mechanical Protection: Corner impact-resistant bumpers on enclosure edges, cylinder end cushioning to reduce impact and collision risk
- Electrical Safety: Four-fold electrical protection — overcurrent, overvoltage, short circuit, and leakage protection
- Electrostatic Protection: Complete grounding system to eliminate ESD damage risk to RF chips
3.5 Expansion and Monitoring Requirements
- Video Monitoring: High-definition camera inside the enclosure for real-time observation of test status, with video recording and storage capability
- Multi-Screen Display: Support simultaneous display of test data and monitoring video on the same screen
- Remote Debugging: Equipped with network port and wireless communication module, supporting remote monitoring and parameter debugging via computer or mobile phone
- Tooling Compatibility: Quick-change positioning fixtures to accommodate different remote control product form factors
—
4. Overall System Design Description
4.1 Design Basis
| Standard | Description |
| — | — |
| GB/T 12190-2006 | General technical requirements for electromagnetic shielding enclosures |
| GB/T 17626.21-2014 | Electromagnetic compatibility — Testing and measurement techniques — Shielding effectiveness testing |
| GB 50054-2011 | Code for design of low voltage electrical installations |
| GB 2894-2008 | Safety signs and guideline for the use |
| — | Customer-provided remote control product dimensions and test process requirements |
4.2 Overall Architecture Design
The system adopts a “intrinsic shielding + enclosure shielding + system control” three-layer architecture, ensuring test accuracy and efficiency comprehensively from product to equipment to system level:
| Layer | Description |
| — | — |
| Product Layer | Standardize remote control PCB shield-can design and grounding processes to improve the product’s own electromagnetic compatibility at the source |
| Equipment Layer | High-shielding-effectiveness sealed enclosure with microwave absorbing material and full-path filtering, providing a clean test environment |
| System Layer | Pneumatic automation + electrical control + signal monitoring + video recording, achieving standardized test workflow and visualized data |
4.3 Remote Control Intrinsic Shielding Design (PCB + Structure)
4.3.1 Core Design Principles
A 2.4GHz electromagnetic wave has a free-space wavelength of approximately 12.5cm, classifying it as a microwave frequency band. Metal shield cans block electromagnetic wave propagation through reflection and absorption, but shielding performance is highly dependent on grounding quality — a poorly grounded shield can becomes a floating metal body that, when excited by RF signals, acts as an equivalent monopole antenna, actually worsening radiation performance. Therefore, the core of shielding design is “low-impedance grounding + minimal aperture/slot control”.
4.3.2 Shield Can Material Selection
For the 2.4G frequency band, the following two materials are prioritized, balancing shielding effectiveness, manufacturability, and cost:
| Material | Characteristics | Typical Application |
| — | — | — |
| Nickel Silver (Copper-Nickel-Zinc Alloy) | Excellent electrical conductivity, good spring properties, strong corrosion resistance; 0.2mm thickness provides tens of dB attenuation for 2.4G waves | High-end products and one-piece spring-contact shield cans |
| Nickel-Plated Brass | Moderate cost, good solderability, nickel plating improves oxidation resistance | Mass-production stamped shield cans |
Recommended material thickness: 0.2mm — this thickness greatly exceeds the skin depth of 2.4G electromagnetic waves, providing ample shielding attenuation while supporting precision stamping with high dimensional accuracy.
4.3.3 Grounding Structure Design
A “four-edge multi-point grounding + corner reinforcement” scheme is adopted to strictly control grounding impedance:
| Design Parameter | Specification |
| — | — |
| Grounding Method | Shield can four edges connected to PCB ground layer via beryllium copper (BeCu) spring clips or reflow-soldered mounting legs, ensuring reliable multi-point contact |
| Spring Clip Specification | BeCu spring clip compression ≥0.3mm, stable contact pressure, maintaining low contact resistance under environmental variations |
| Via Spacing | Engineering practice of 2–3mm via pitch, far smaller than λ/20 (approximately 6mm), preventing slot resonance-induced shielding failure |
| Corner Reinforcement | Grounding points must be provided at all four right-angle corners of the shield can to suppress corner electromagnetic leakage and resonance |
| Resistance Requirement | DC resistance between shield can and PCB GND <0.1Ω, verified using four-wire (Kelvin) measurement |
4.3.4 Aperture and Thermal Dissipation Design
Shield can openings must satisfy both thermal dissipation and shielding requirements, following these design specifications:
| Design Rule | Specification |
| — | — |
| Aperture Size Limit | Individual hole diameter ≤2mm, far smaller than λ/20, controlling single-hole leakage |
| Hole Pattern | Staggered (quincunx) arrangement for better shielding effectiveness at the same open-area ratio |
| Land/Bridge Width | Metal bridge width between adjacent holes ≥0.5mm, ensuring electrical continuity and structural strength |
| Placement Avoidance | No holes directly above RF circuits or antenna matching areas to prevent direct radiation |
4.3.5 Common Failure Mode Avoidance
Typical symptom of poor shield can grounding: After installing the shield can, the radiated emission (RE) test margin at certain frequency points actually decreases, or even exceeds the limit.
Root cause: Excessive grounding impedance causes the shield can to be excited into resonance, effectively acting as a radiating antenna. The shield can, intended to suppress radiation, instead becomes an unintended radiator — amplifying the very problem it was designed to solve.
4.4 Shielding Enclosure System Design
4.4.1 Enclosure Structure
The shielding enclosure adopts a split upper/lower flip-open structure. The lower housing provides fixed support while the upper lid flips open for easy access, ensuring excellent sealing and operational convenience:
- Main body material: High-quality cold-rolled steel plate, welded construction, offering high rigidity and resistance to deformation
- Shielding lining: Blue composite shielding lining built into the enclosure — a dual-layer structure combining conductive foam with metal mesh to enhance absorption loss
- Sealing structure: Continuous conductive sealing gasket installed along the upper lid’s edge, forming a complete conductive loop when closed
- Surface finish: Off-white electrostatic powder coating — aesthetically pleasing, wear-resistant, compliant with industrial equipment appearance standards
4.4.2 Shielding Performance Assurance
- Seam treatment: All welded joints use continuous full penetration welding, ground smooth to eliminate seam leakage
- Feedthrough treatment: All panel penetrations (air lines, cables, connectors) use dedicated shielding connectors and filtering components
- Absorption design: 2.4G-specific pyramidal absorber material mounted on the interior walls to reduce standing wave reflection and simulate a free-space test environment
- Performance verification: Shielding effectiveness test conducted per standard before factory delivery, with test data provided
4.5 Pneumatic Drive System Design
4.5.1 System Composition
The pneumatic system is divided into two independent circuits — upper lid drive and internal product pressing — powered by a unified air source with independently controlled solenoid valve banks:
- Upper lid drive: Two standard cylinders installed symmetrically with double-end cushioning to drive smooth flip opening of the lid
- Product pressing: Multiple compact guided-rod cylinders, one per test station, providing precise pressing force on the product under test
- Control unit: Multi-valve integrated solenoid valve bank, controlled at DC24V safe voltage for fast response
- Air source treatment: FRL (Filter-Regulator-Lubricator) unit installed at the front end — integrated filtration, pressure regulation, and oil mist lubrication to protect pneumatic component service life
4.5.2 Safety Design
- Two-hand start: Upper lid opening/closing requires simultaneous pressing of both start buttons, preventing accidental hand-trapping
- Cushion deceleration: Hydraulic shock absorbers at end positions of the cylinder stroke to reduce impact and lower noise
- E-stop interlock: All cylinders stop immediately and hold their position when the emergency stop is triggered
4.6 Electrical Control System Design
4.6.1 Control Architecture
A DC24V low-voltage control architecture is adopted for safety, reliability, and clean wiring:
- Power unit: Industrial-grade switching power supply, AC220V input / DC24V output, equipped with comprehensive protection functions
- Operation unit: Integrated operator panel with start buttons, E-stop button, and function buttons arranged in clearly marked zones
- Communication unit: Equipped with Ethernet port and wireless communication module, supporting remote monitoring and debugging via PC or mobile
- Wiring standard: Separation of power and signal lines, wire bundles with numbered identification, securely crimped terminals for easy maintenance
4.6.2 Safety Protection
- Emergency stop protection: Twist-release E-stop button — one-touch shutdown of the control circuit
- Overcurrent protection: Independent fuse for each circuit to prevent short-circuit fault propagation
- Grounding protection: Complete equipment grounding for electrical safety
4.7 2.4G RF-Specific System Design
4.7.1 Absorber and Sealing Components
- Pyramidal absorber material: Flame-retardant polyurethane base with ferrite coating, reflectance ≤ -20dB in the 2.4G band, providing effective spurious signal absorption
- Conductive foam gasket: Copper-nickel composite plating, resistivity ≤ 0.05 Ω·cm, good compression recovery, shielding effectiveness ≥ 100dB
- Conductive sealant & rubber O-rings: Used for interface and feedthrough filling, achieving 360° continuous shielding
4.7.2 Antenna and Transmission Components
- Near-field directional antenna: Gain ≥ 8dBi, beam width ≤ 30°, 50Ω impedance, VSWR ≤ 1.2, signal delay ≤ 100ms
- Impedance matching module: Matching ratio ≥ 99%, maximizing signal transmission efficiency and minimizing reflection loss
- Low-loss coaxial cable: DC-6GHz broadband, double shielding, minimal signal loss, fitted with standard SMA adapters
- Adjustable mounting bracket: Multi-angle adjustable for convenient tuning of antenna direction and distance
4.7.3 Interface Filtering Components
- USB EMI filter: ≥ 100dB out-of-band rejection at 2.4G, with overcurrent and ESD protection, used for USB devices such as cameras
- DC power line filter: ≥ 100dB rejection at 2.4G band, compatible with 12V-24V, blocking conducted interference through power lines
- Shielding feedthrough connectors: All-metal shielded fittings for air lines, ensuring shielding continuity at pneumatic panel penetration points
4.8 Real-Time Signal Monitoring System Design
4.8.1 Core Functional Modules
- Signal power control module: Power adjustment range -30dBm ~ +10dBm, attenuation range 0-120dB, high step precision
- Band selection module: SAW (Surface Acoustic Wave) filter, 1MHz passband, ≥ 100dB out-of-band rejection, precise frequency selection
- Audible/visual alarm module: Automatically triggers audible and visual alarms upon signal out-of-tolerance or shielding leakage to alert operators
4.8.2 Display Units
Multiple industrial display configurations serve diverse application scenarios:
- Embedded touch display: Integrated into the equipment body, capacitive touch, real-time display of signal power, attenuation values, and other parameters
- External monitoring display: Metal-enclosed industrial monitor for surveillance video and consolidated data viewing
- Dedicated power display: Standalone display for power adjustment parameters — intuitive and clear
- Multi-screen switchable display: Supports multiple simultaneous inputs with on-screen switching for at-a-glance data and imaging
4.9 Test Fixture System Design
4.9.1 Fixture Architecture
A three-layer structure of “aluminum frame + insulated base + custom tooling” balances strength, insulation, and adaptability:
- Support frame: Industrial aluminum profile construction with corner brackets — stable and flexibly adjustable
- Fixture base: Bakelite/phenolic resin material with excellent insulation, high mechanical strength, and high-visibility orange color
- Positioning tooling: White POM material, custom-machined to match remote control contours, incorporating locating pins and positioning slots for precise alignment
- Quick-release clamps: Vertical-action toggle clamps with rubber press heads to assist product retention; tooling can be quickly swapped
4.9.2 Test Connectivity
- Test probes: Custom pogo pin probes with gold-plated contacts — low contact resistance, long service life, matched to product test points
- Adapter PCB boards: Custom signal transition boards providing reliable interconnection between probe signals and external test equipment
- Insulating spacers: Epoxy board and silicone gaskets providing insulation between tooling and frame to prevent signal short circuits
4.10 Video Recording System Design
- HD camera module: 1080P resolution, wide-angle lens, built-in LED fill light — adapted for low-light conditions inside the enclosure
- Dedicated filter: Camera signal-specific filtering to eliminate interference with 2.4G testing
- Control panel: Custom imaging control unit integrating switching, lighting adjustment, and recording control functions
4.11 Power Distribution and Safety Protection System Design
- Integrated power distribution mainframe: Rack-mounted design, AC110-240V wide-range input, multiple outputs, integrated multi-layer protection
- Power input filter module: AC220V/20A, ≥ 100dB rejection at 2.4G, blocking conducted interference through power lines
- ESD grounding module: Brass grounding terminal with yellow/green ground cable, grounding resistance ≤ 4Ω
- Power distribution module: Multiple independent DC output channels with individual circuit protection — clean layout for easy maintenance
5. System Configuration & Quotation List
| No. | Product Name | Model | Specification | Qty | Unit | Brand | Remarks |
| —– | ————– | ——- | ————— | —– | —— | ——- | ——— |
| I. Equipment Enclosure and Housing System | |||||||
| 1 | Lower Housing Base | JC-CAB-Base01 | Cold-rolled steel, powder-coated (off-white), built-in blue EM shielding lining, dimensions customized per equipment | 1 | Set | KITOZER | Main structural support |
| 2 | Upper Lid Shielding Door | JC-CAB-Lid01 | Cold-rolled steel, powder-coated (off-white), stainless steel edge banding, built-in conductive shielding gasket | 1 | Set | KITOZER | Flip-type shielding cover |
| 3 | Upper Lid Flip Support Columns | JC-CAB-Strut01 | Stainless steel, spherical plain bearings at both ends | 2 | Pcs | KITOZER | Symmetrical installation |
| 4 | Side Safety Bumper Strips | JC-CAB-Prot01 | Yellow PVC/rubber material, anti-collision warning design | 2 | Pcs | KITOZER | Impact protection |
| 5 | Operator Panel Base | JC-CAB-PanelBase01 | Cold-rolled steel, powder-coated (off-white), integrated button mounting positions | 1 | Set | KITOZER | Front lower section of equipment |
| 6 | Upper Lid Ground Terminal Assembly | JC-CAB-GndTerm01 | Aluminum mounting plate + red/black terminals, φ4mm | 1 | Set | KITOZER | Upper lid right corner |
| 7 | Equipment Labeling & Warning Decals | JC-CAB-Label01 | Includes yellow EM/high-voltage warning labels, equipment info nameplate | 1 | Batch | KITOZER | Warning + nameplate |
| 8 | Shielding Seal Gasket | JC-CAB-EMIStrip01 | Conductive foam/copper spring fingers, mounted along mating surfaces | 1 | Set | KITOZER | Ensures shielding performance |
| II. Pneumatic Drive & Control System | |||||||
| 9 | Lid Drive Cylinder | JC-PNEU-Cyl01 | Stainless steel standard cylinder, double cushioning, SC40×50 | 2 | Pcs | AirTAC | Symmetrical installation |
| 10 | Internal Test Press Cylinder | JC-PNEU-Cyl02 | Compact guided-rod cylinder, SC32×50 | 10 | Pcs | AirTAC | Mounted on internal aluminum frame |
| 11 | Pneumatic Solenoid Valve Bank | JC-PNEU-Valve01 | 5/2-way solenoid valves, DC24V control, 15 valve positions | 1 | Set | AirTAC | Controls all cylinders |
| 12 | FRL Unit | JC-PNEU-FRL01 | Filter, regulator, lubricator with pressure gauge | 1 | Set | AirTAC | Front-end air treatment |
| 13 | Pneumatic Quick Fittings | JC-PNEU-Fitting01 | Straight/elbow/tee types, for φ4/φ6 tubing | 1 | Batch | AirTAC | Connection accessories |
| 14 | PU Air Tubing | JC-PNEU-Tube01 | Transparent/blue, φ4/φ6 two sizes | 1 | Batch | AirTAC | Compressed air delivery |
| 15 | Cylinder Silencers | JC-PNEU-Muffler01 | Plastic/metal, fits solenoid valve exhaust ports | 15 | Pcs | AirTAC | Exhaust noise reduction |
| 16 | Cylinder Mounting Brackets | JC-PNEU-Mount01 | Aluminum/stainless steel | 1 | Set | KITOZER | Cylinder fixation |
| III. Operator Panel & Electrical Control Components | |||||||
| 17 | Large Green Start Button | JC-ELEC-BtnG01 | 22mm diameter, illuminated, momentary, DC24V | 2 | Pcs | Schneider | Two-hand safety operation |
| 18 | Red E-Stop Button | JC-ELEC-BtnR01 | 22mm diameter, twist-release | 1 | Pcs | Schneider | Panel center |
| 19 | Small Green Function Buttons | JC-ELEC-BtnG02 | 16mm diameter, momentary, DC24V | 6 | Pcs | Schneider | With printed legends |
| 20 | Button Mounting Panel | JC-ELEC-Panel01 | Metal panel with printed function legends | 1 | Pcs | KITOZER | Houses all buttons |
| 21 | Equipment Switching Power Supply | JC-ELEC-PS01 | DC24V output, rated for control circuit load | 1 | Unit | Mean Well | Powers solenoid valves, buttons |
| 22 | Signal Interface Module | JC-ELEC-IO01 | Ethernet/communication ports, WiFi/Bluetooth support, remote monitoring/debugging | 1 | Set | KITOZER | Test data transmission |
| 23 | Internal Wiring & Terminals | JC-ELEC-Wire01 | High-temp multi-core copper wire, with terminals and numbered sleeves | 1 | Batch | KITOZER | Internal electrical connections |
| 24 | Fixture Power Switch | JC-ELEC-PowerSw01 | Rocker/rotary type, mounted on fixture side | 1 | Pcs | Schneider | Fixture main power control |
| IV. Test Fixture & Carrier System | |||||||
| 25 | Fixture Base | JC-FIXT-Base01 | Bakelite/phenolic resin, custom-machined | 1 | Set | KITOZER | Orange insulated base |
| 26 | Product Positioning Tooling | JC-FIXT-Locator01 | White POM, with positioning slots and pins, 8 stations | 8 | Sets | KITOZER | Secures DUT |
| 27 | Manual Quick Clamps | JC-FIXT-Clamp01 | Vertical action, with rubber press head | 2 | Sets | Clamptek | Auxiliary product retention |
| 28 | Test Probe Assembly | JC-FIXT-Probe01 | Custom pogo pin probes, matched to product test points | 1 | Set | Huarong | Electrical test connectivity |
| 29 | Internal Aluminum Support Frame | JC-FIXT-Frame01 | Industrial aluminum profiles with corner brackets and fasteners | 1 | Set | KITOZER | Mounts cylinders and fixtures |
| 30 | Fixture Insulating Spacers | JC-FIXT-Insulator01 | Epoxy board/silicone | 1 | Batch | KITOZER | Insulation between fixture and frame |
| 31 | Test Adapter PCB Boards | JC-FIXT-PCB01 | Custom transition boards, connecting probes to external equipment | 1 | Set | KITOZER | Signal transition/transmission |
| V. Shielding, Safety & Auxiliary Accessories | |||||||
| 32 | EM Shielding Lining | JC-SHD-Liner01 | Conductive foam/metal mesh, blue coating | 1 | Set | KITOZER | Enhances shielding performance |
| 33 | Cylinder Shock Absorbers | JC-SHD-Buffer01 | Hydraulic/rubber type | 15 | Pcs | AirTAC | Reduces impact and noise |
| 34 | Stainless Steel Fasteners | JC-SHD-Fastener01 | Full set of screws, nuts, washers | 1 | Batch | Dongming | General mounting hardware |
| 35 | Cable/Tubing Management | JC-SHD-CableMgmt01 | Cable ties, clamps, tube clips | 1 | Batch | KITOZER | Organizes wiring and tubing |
| 36 | Equipment Grounding Assembly | JC-SHD-Ground01 | Yellow/green ground cable, compatible with ground terminals | 1 | Set | KITOZER | Safety grounding |
| 37 | Maintenance Access Screws | JC-SHD-MaintScrew01 | Stainless steel, for service openings | 1 | Batch | KITOZER | For after-sales maintenance |
| VI. Optional Expansion Accessories | |||||||
| 38 | External High-Precision Air Filter | JC-OPT-Filter01 | Oil-water separator + precision filtration | 1 | Set | SMC | Optional per requirement |
| 39 | Equipment Dust Cover | JC-OPT-DustCover01 | Transparent PVC, sized to equipment | 1 | Set | KITOZER | Dust protection when idle |
| 40 | Host Computer Communication Cable | JC-OPT-CommCable01 | Dedicated cable for Ethernet/Serial port | 1 | Pcs | SAMZHE | Connects to test PC |
| VII. 2.4G Band-Specific Components | |||||||
| 41 | 2.4G Pyramidal Absorber Material | JC-RF-Absorber01 | 300×300×20mm, reflectance ≤ -20dB @2.4G, flame-retardant polyurethane + ferrite coating | 1 | Set | KITOZER | Internal absorption |
| 42 | EM Shielding Conductive Foam Gasket | JC-RF-Gasket01 | 10×20mm, copper-nickel composite, resistivity ≤ 0.05Ω·cm, SE ≥ 100dB | 1 | Set | KITOZER | Enclosure sealing |
| 43 | Conductive Sealant / Conductive Rubber O-rings | JC-RF-Sealant01 | Conductive sealant + Φ8mm power inlet conductive rubber ring | 1 | Set | KITOZER | Interface sealing |
| 44 | 2.4G Near-Field Directional Control Antenna | JC-RF-Antenna01 | Gain ≥ 8dBi, beam width ≤ 30°, 50Ω, VSWR ≤ 1.2, 0-1m delay ≤ 100ms | 1 | Set | KITOZER | Signal Tx/Rx |
| 45 | Antenna Impedance Matching Module | JC-RF-Match01 | Matching ratio ≥ 99% | 1 | Set | KITOZER | Impedance matching |
| 46 | 50Ω Coaxial Cable + SMA Adapter | JC-RF-Cable01 | DC-6GHz, low-loss shielded type | 1 | Set | Rosenberger | Signal transmission |
| 47 | Antenna Adjustable Mounting Bracket | JC-RF-Mount01 | Adjustable angle, for internal mounting | 1 | Set | KITOZER | Antenna fixation |
| 48 | USB 2.0 EMI Filter | JC-RF-USBFilter01 | ≥ 100dB rejection at 2.4G band, Type-A, overcurrent/ESD protection | 2 | Pcs | KITOZER | USB port filtering |
| 49 | DC Power EMI Filter | JC-RF-DCFilter01 | ≥ 100dB rejection at 2.4G, compatible with 12V-24V | 1 | Pcs | KITOZER | Power filtering |
| 50 | Φ8mm Compressed Air Feedthrough | JC-RF-AirFeed01 | All-metal shielded sealed | 1 | Set | KITOZER | Air line shielding penetration |
| 51 | Air Line Sealing Base | JC-RF-AirBase01 | Anti-loosening, IP65 rated | 1 | Set | KITOZER | Fixing and sealing |
| VIII. Signal Real-Time Monitoring & Control System | |||||||
| 52 | Signal Power Control Module | JC-SMS-ATT01 | Range -30dBm ~ +10dBm, attenuation 0-120dB, integrated into host | 1 | Set | KITOZER | Power adjustment |
| 53 | Band Selection Module (SAW Filter) | JC-SMS-Filter01 | 1MHz passband, ≥ 100dB out-of-band rejection, integrated into host | 1 | Set | KITOZER | Frequency selection/filtering |
| 54 | Abnormal Audible/Visual Alarm Module | JC-SMS-Alarm01 | Auto-alarm for signal out-of-tolerance or leakage, integrated into host | 1 | Set | KITOZER | Fault warning |
| 55 | 7″ Industrial Touch Display | JC-SMS-Disp01 | 1024×600 resolution, HDMI input, capacitive touch | 1 | Unit | Weinview | Host integrated display |
| 56 | 21.5″ Monitoring Display | JC-SMS-Disp02 | 1080P, metal enclosure, HDMI/VGA dual input | 1 | Unit | Dell | External monitoring display |
| 57 | Dedicated Signal Power Display | JC-SMS-Disp03 | 7″ embedded, RS232/485 communication support | 1 | Unit | KITOZER | Power parameter display |
| 58 | Multi-Screen Switchable Display | JC-SMS-Disp04 | 10.1″, multi-input switching | 1 | Unit | KITOZER | Multi-display |
| IX. Power Distribution & Safety Protection System | |||||||
| 59 | Integrated Power Distribution Mainframe | JC-PDS-01 | 1U rack-mount, AC110-240V input, 200W output, overcurrent/overvoltage/short-circuit/leakage protection | 1 | Set | Mean Well | Main power distribution |
| 60 | AC220V/20A Input Filter Module | JC-PDS-EMI01 | ≥ 100dB rejection at 2.4G | 1 | Set | KITOZER | Power input filtering |
| 61 | ESD Grounding Module | JC-PDS-Ground01 | Grounding resistance ≤ 4Ω, M6 brass terminal | 1 | Set | KITOZER | Static discharge |
| 62 | Power Output Distribution Module | JC-PDS-Dist01 | Multiple DC12V/24V outputs with individual protection | 1 | Set | KITOZER | Branch power supply |
| X. Test Observation & Video Recording System | |||||||
| 63 | Built-in HD Camera Module | JC-CAM-1080P | 1080P, USB output, LED fill light, 120° wide angle | 1 | Set | Hikvision | Internal monitoring |
| 64 | Camera Dedicated Filter | JC-CAM-Filter01 | Dedicated 2.4G suppression | 1 | Unit | KITOZER | Signal interference elimination |
| 65 | PCL Signal Filter | JC-CAM-PCLFilter | Dedicated 2.4G suppression | 1 | Unit | KITOZER | Signal filtering |
| 66 | Imaging Control Panel | JC-CAM-CtrlPanel | Custom panel, integrated imaging switch and controls | 1 | Unit | KITOZER | Operation control |
| XI. Custom Tooling (Bathroom Heater Remote Control) | |||||||
| 67 | Bathroom Heater Remote Control Test Tooling | JC-FIXT-Remote01 | Custom per remote control dimensions, key positions, test requirements; includes locating fixture | 1 | Set | KITOZER | Exclusive customization |
Total Amount: Excluding tax and freight; freight calculated at 3% of total amount, freight collect; special VAT invoice tax calculated at (total amount + freight) × 13%; warranty period: 1 year.
6. Detailed Technical Specifications of System Products
6.1 Equipment Main Cabinet and Enclosure System
6.1.1 Lower Cabinet Main Unit Base (JC-CAB-Base01)
Structural Parameters
- Main material: 1.5mm high-quality cold-rolled steel plate, grade SPCC, compliant with GB/T 708-2019 (Cold-rolled steel sheet and strip standard)
- Lining material: Blue composite electromagnetic shielding lining, composed of conductive foam combined with 80-mesh tin-plated copper mesh
- External dimensions: Customized according to the product under test and tooling; standard configuration 500mm × 450mm × 300mm, tolerance ±0.5mm
- Welding process: Continuous full-seam CO₂ gas-shielded welding, weld height ≥2mm, free from cold welds, missed welds, or burn-through defects
- Surface treatment: Degreasing → pickling → phosphating → electrostatic powder coating, coating thickness 60–80μm, color RAL9003 off-white
- Structural strength: Uniform load-bearing capacity ≥50kg, deflection at full load ≤0.2mm
Electrical & Shielding Parameters
- Base shielding effectiveness: ≥80dB @ 2.4GHz (excluding door seam)
- Insulation resistance: Insulation resistance between inner and outer walls ≥100MΩ
- Grounding resistance: Resistance between ground terminal and main body ≤0.01Ω
Environmental Adaptability
- Operating temperature: -10°C ~ +50°C
- Storage temperature: -20°C ~ +60°C
- Relative humidity: 5% ~ 95%, non-condensing
- Protection rating: IP54 when closed
- Applicable standards: GB/T 12190-2006 (Electromagnetic shielding enclosure performance testing standard), GB/T 708-2019
6.1.2 Upper Cover Shielding Door (JC-CAB-Lid01)
Structural Parameters
- Main material: 1.2mm cold-rolled steel plate, with 1.0mm stainless steel edge trim
- Sealing structure: One continuous loop of conductive foam sealing gasket; continuous contact when compressed to 30%
- Hinge mechanism: Stainless steel pivot shaft with damping structure, opening angle 0–95°
- Surface treatment: Same as lower cabinet, off-white electrostatic powder coating
Performance Parameters
- Shielding effectiveness when closed: ≥100dB @ 2.4GHz
- Opening/closing cycle life: ≥100,000 cycles
- Closure pressure uniformity: Pressure deviation at all contact points ≤15%
- Configuration: Includes grounding copper strap, observation window (optional), and handle
6.1.3 Additional Cabinet Accessories
| Component | Specification |
| — | — |
| Hinge support column | 304 stainless steel, diameter 12mm, spherical plain bearings at both ends, swing angle ±15°, single-column load capacity ≥20kg |
| Safety protection strip | Yellow PVC rubber, thickness 10mm, anti-collision cushioning with clear warning markings |
| Ground terminal assembly | Aluminum mounting plate, red/black dual-color φ4mm banana socket, contact resistance ≤5mΩ |
| Identification labels | PVC material, waterproof and oil-resistant; includes 1× EMC warning label, 1× high-voltage warning label, and 1× equipment nameplate |
| EMI shielding gasket | Copper-nickel conductive fabric wrapped foam, thickness 10mm, width 20mm, resistivity ≤0.05Ω·cm |
6.2 Pneumatic Drive and Control System
6.2.1 Upper Cover Drive Cylinder (JC-PNEU-Cyl01)
| Parameter | Specification |
| — | — |
| Type | Double-acting standard cylinder, SC series |
| Bore diameter | 40mm; stroke: 50mm |
| Working medium | Compressed air, filtration accuracy 40μm |
| Working pressure | 0.15–0.8MPa, rated 0.5MPa |
| Cushion type | Adjustable pneumatic cushioning at both ends |
| Piston speed | 50–500mm/s |
| Operating temperature | -20°C ~ +80°C |
| Seal material | Nitrile rubber (NBR) |
| Cylinder barrel material | Stainless steel; piston rod: chrome-plated alloy steel |
| Theoretical thrust | 628N (at 0.5MPa) |
| Mounting type | LB foot bracket mounting |
| Service life | ≥5 million cycles |
6.2.2 Internal Press-Down Cylinders (JC-PNEU-Cyl02)
| Parameter | Specification |
| — | — |
| Type | Thin cylinder with guide rods, MGPM series |
| Bore diameter | 32mm; stroke: 50mm |
| Guide rod quantity | 2 rods, high-precision ball bearing guidance |
| Repeatability accuracy | ±0.05mm |
| Working pressure | 0.2–0.7MPa |
| Operating temperature | -10°C ~ +60°C |
| Press head material | Rubber overmolded head to prevent product scratching |
| Key features | Torsion-resistant, smooth operation, ideal for precision press-down applications |
| Quantity | 10 units (8 for designated stations, 2 as spares) |
6.2.3 Solenoid Valve Bank and Air Source Treatment
- Solenoid valves: 5/2-way single solenoid pilot, DC24V, response time ≤10ms, IP65 protection, 15-valve integrated manifold block
- Air treatment unit (FRL): Filtering accuracy 5μm, pressure regulation range 0.05–0.9MPa, with pressure gauge, automatic drain type
- Mufflers: Plastic porous type, noise reduction ≥20dB, G1/8 thread
- Air tubing: PU material, blue φ6mm + transparent φ4mm, pressure rating ≥1MPa
- Fittings: All-copper nickel-plated, push-in quick-connect type, reliable sealing
6.3 Operating Panel and Electrical Control Components
6.3.1 Buttons and Switches
- Start button: φ22mm, flat round, green with LED indicator, self-resetting, DC24V, IP65, contact rating 5A
- Emergency stop button: φ22mm, red mushroom head, twist-to-release, normally closed contact, IP65
- Function buttons: φ16mm, green, self-resetting, DC24V, 6 units corresponding to different functions
- Power switch: Rocker type, 250V/10A, ON-OFF two-position, with indicator light
6.3.2 Switching Power Supply (JC-ELEC-PS01)
| Parameter | Specification |
| — | — |
| Input voltage | AC100–240V, 50/60Hz, wide range |
| Output voltage | DC24V, rated current 5A |
| Power | 120W |
| Voltage regulation accuracy | ±1% |
| Ripple & noise | ≤100mVpp |
| Protection functions | Overcurrent, overvoltage, short-circuit, overtemperature |
| Operating temperature | -10°C ~ +60°C |
| Service life | ≥50,000 hours |
| Certifications | CE, CCC |
6.3.3 Signal Interface Module (JC-ELEC-IO01)
- Communication interfaces: RJ45 Ethernet ×1, RS232 serial ×1
- Wireless communication: WiFi 2.4G, Bluetooth 4.2
- Supported protocols: TCP/IP, Modbus RTU
- Power supply: DC24V
- Functions: Remote parameter configuration, data reading, firmware upgrade
- Host software: Supports Windows OS, real-time data curve display
6.4 Test Tooling and Carrier System
6.4.1 Tooling Base and Frame
- Tooling base: Phenolic resin board (bakelite), thickness 20mm, orange color, insulation resistance ≥10¹²Ω, flatness ≤0.1mm
- Support frame: 4040 industrial aluminum profile, anodized finish, corner bracket connections, height adjustable
- Insulation spacers: Epoxy board + silicone pad, thickness 3mm, dielectric withstand ≥10kV
6.4.2 Positioning Fixtures and Test Probes
- Positioning fixtures: White POM material, CNC machined, tolerance ±0.05mm, with locating pins and limit slots, 8 stations
- Quick-action clamps: Vertical type, clamping force ≥50kg, rubber-coated handle
- Test probes: Pogo-pin type, flat/round head options, gold-plated barrel, travel 5mm, contact resistance ≤20mΩ, life ≥100,000 cycles
- Adapter PCB: FR-4 material, thickness 1.6mm, immersion gold finish, 50Ω impedance control
6.5 2.4GHz Band Dedicated Components
6.5.1 Pyramidal Absorber Material (JC-RF-Absorber01)
| Parameter | Specification |
| — | — |
| Material | Flame-retardant polyurethane foam + ferrite absorber |
| Dimensions | 300mm × 300mm × 20mm |
| Reflectivity | ≤-20dB @ 2.4GHz |
| Flame retardancy | UL94 V-0 |
| Operating temperature | -40°C ~ +120°C |
| Mounting method | Adhesive backing |
| Key features | Lightweight, excellent absorption performance, ideal for in-box near-field testing |
6.5.2 Directional Antenna (JC-RF-Antenna01)
| Parameter | Specification |
| — | — |
| Operating frequency | 2400–2500MHz |
| Gain | ≥8dBi |
| VSWR | ≤1.2 |
| Impedance | 50Ω |
| Polarization | Vertical |
| Beam width | Horizontal ≤30°, vertical ≤30° |
| Connector | SMA-K |
| Power handling | 50W |
| Material | ABS housing, copper radiating element |
6.5.3 EMI Filters
- USB filter: Type-A male to female, 2.4G suppression ≥100dB, overcurrent protection 500mA, ESD protection ±15kV
- DC filter: Input/output DC12–24V, rated current 5A, 2.4G common-mode suppression ≥100dB
- Power line filter: AC220V/20A, differential-mode suppression ≥60dB, common-mode suppression ≥100dB @ 2.4G
6.6 Real-Time Signal Monitoring and Display System
6.6.1 Power Control and Filter Module
| Parameter | Specification |
| — | — |
| Power adjustment range | -30dBm ~ +10dBm |
| Attenuation range | 0–120dB, 1dB step |
| Attenuation accuracy | ±0.5dB |
| Operating frequency | 2–3GHz |
| SAW filter | Center frequency 2450MHz, bandwidth 1MHz, out-of-band rejection ≥100dB |
| Input/output impedance | 50Ω |
| Power supply | DC12V |
6.6.2 Industrial Display Screens
- 7-inch touchscreen: Resolution 1024×600, capacitive 10-point touch, brightness 300cd/m², HDMI + VGA inputs, metal housing
- 21.5-inch monitoring screen: 1920×1080 full HD, IPS panel, brightness 250cd/m², HDMI/VGA/BNC multi-interface, metal housing, wall-mount type
- Multi-view display: 10.1-inch, supports 4-channel video input, split-screen simultaneous display
6.7 Power Distribution and Imaging System
- Power distribution unit: 1U rack-mount type, multiple outputs, total power 200W, integrated overcurrent, overvoltage, short-circuit, and leakage protection
- Camera: 1080P 2-megapixel, 120° wide-angle lens, USB2.0 output, built-in 6 LED fill lights with adjustable brightness
- Grounding module: M6 brass terminal, 6mm² yellow-green grounding cable, 2m length, grounding resistance ≤4Ω
—
7. Core Advantages of the Solution
7.1 Leading Shielding Performance for Accurate Test Data
The system adopts a dual-architecture design with product-level intrinsic shielding combined with equipment-level enclosure shielding, achieving a shielding effectiveness of ≥100dB in the 2.4GHz band — significantly above the industry norm. Full-path shielding design ensures that every penetration point for power, signal, and pneumatic lines is fitted with dedicated filters and shielded connectors, leaving no leakage paths. Built-in high-performance absorber material eliminates in-box standing-wave reflections, delivering test data with high correlation to anechoic chamber results and excellent repeatability.
7.2 High Automation Level for Maximum Efficiency
Pneumatic automatic open/close cover combined with automatic press-down, and a two-hand button one-key operation, significantly reduces manual labor. The 8-station batch testing configuration enables multiple units to be tested in a single loading cycle, improving test efficiency by more than 5 times. Test data is automatically recorded and exported, eliminating manual recording errors and providing full traceability for quality analysis.
7.3 Strong Customization Capability for Multiple Product Types
Tooling fixtures can be customized according to remote control dimensions, key positions, and test points, with quick-change capability. Signal power and attenuation levels are flexibly adjustable to suit different chip specifications and test standards. The system supports expansion options including safety light curtains, barcode scanners, and automatic loading/unloading mechanisms to integrate with production line automation upgrades.
7.4 Multi-Level Safety Protection for Reliable Long-Term Operation
Mechanical, electrical, and operational triple-layer safety protection with emergency stop, two-hand start, and cushioned anti-collision mechanisms. Core components are sourced from industry-leading brands, ensuring low failure rates and extended service life. Every unit undergoes a rigorous factory testing procedure including shielding effectiveness verification, airtightness testing, and burn-in aging tests before shipment.
7.5 Full Lifecycle Service Assurance — Worry-Free After-Sales
Our professional team provides free requirements investigation and solution design, delivering a fully customized optimal configuration. As a manufacturer, we control production quality in-house and guarantee short lead times. Warranty term, support hours, installation, and training are confirmed on the quotation.
—
8. Technical Q&A
8.1 Shielding Fundamentals
Q1: Why is a dedicated shielding enclosure mandatory for 2.4GHz remote control testing?
A: The 2.4GHz band is an unlicensed ISM band saturated with electromagnetic interference from WiFi, Bluetooth, and countless wireless devices. Testing in an open environment allows external signals to contaminate measurement results, causing significant deviation and poor repeatability in power and sensitivity readings. A dedicated shielding enclosure provides a high-isolation environment of ≥100dB, blocking external interference while preventing the device under test from radiating outward. This guarantees accurate, reliable test results — making it essential equipment for remote control RF performance testing.
Q2: Why can poor grounding of a shielding cover actually increase radiation?
A: A metal shielding cover is inherently a conductor. If inadequately grounded, it becomes a floating metal body. When RF signals from the PCB couple spatially onto the cover, the energy cannot be discharged to ground, which excites resonance in the cover. At this point, the cover behaves as a monopole antenna, radiating electromagnetic waves outward and actually worsening the product’s EMC performance. The essence of shielding lies not in “closing the lid” but in achieving “proper grounding.”
Q3: What shielding effectiveness level is considered acceptable for a 2.4GHz shielding enclosure?
A: For consumer electronics remote control testing, the industry-standard requirement is shielding effectiveness ≥80dB @ 2.4GHz, which satisfies most routine test needs. For high-precision measurement or low-sensitivity testing, we recommend a high-performance model with ≥100dB, which provides more stable and accurate test data. The shielding enclosure configured in this solution achieves an overall shielding effectiveness of ≥100dB, placing it in the high-performance class.
Q4: What does the λ/20 aperture rule mean? What aperture size corresponds to 2.4GHz?
A: Electromagnetic wave leakage through apertures is related to the ratio of aperture dimension to wavelength. When the aperture is much smaller than the wavelength, leakage is negligible. Engineering practice commonly uses λ/20 as the safe aperture threshold, where single-aperture leakage can be ignored. The free-space wavelength of a 2.4GHz signal is approximately 12.5cm, making λ/20 approximately 6.25mm. To retain sufficient safety margin, engineers typically specify apertures of 1.5–2mm, which satisfies both ventilation requirements and shielding effectiveness.
8.2 System Installation and Commissioning
Q5: What site conditions are required for installing the shielding enclosure?
A: Three basic site conditions are required: (1) an AC220V/10A power outlet with proper grounding; (2) a compressed air source of 0.5–0.8MPa with a standard quick-connect fitting; and (3) a flat, sturdy bench or floor with adequate working space. The equipment has a compact footprint and can be placed on a standard workbench — no special civil engineering is required.
Q6: How is the shielding effectiveness of the enclosure verified?
A: The standard verification method is the signal generator + spectrum analyzer test: place a transmitting antenna inside the enclosure transmitting at a fixed 2.4GHz power level, position a receiving antenna outside, and measure the received power with the door both open and closed. The difference is the shielding effectiveness. We provide third-party or in-house test reports at the factory, and customers can independently verify using their own spectrum analyzer.
Q7: Do the antenna position and angle need adjustment? What is the optimal setup?
A: Yes, adjustment is required. Antenna distance and angle directly affect measurement consistency and repeatability. We recommend aligning the antenna with the antenna location of the device under test, maintaining a distance of 10–30cm, and fine-tuning the angle while monitoring received power until the strongest and most stable reading is achieved, then securing the bracket. Keep the position fixed during batch testing to ensure consistent results.
8.3 Troubleshooting and Maintenance
Q8: Why does shielding effectiveness degrade after extended use?
A: The three most common causes are: (1) the conductive sealing gasket accumulates dust, wears, or ages, causing poor contact; (2) enclosure seams or feed-through connectors become loose; and (3) filter performance deteriorates. Routine maintenance should include periodic cleaning of the sealing gasket, checking fasteners, and replacing aged components. The typical service life of the sealing gasket is 2–3 years; with regular maintenance, shielding performance can be sustained long-term.
Q9: What should be done if cylinder action becomes slow or weak?
A: First, check whether the air source pressure reaches 0.5MPa — insufficient pressure causes slow/weak action. Next, inspect the FRL unit filter element for blockage and perform regular draining. Check whether the air tubing is kinked or leaking. If all of the above are normal, examine whether the solenoid valve is sticking or the cylinder seals are worn.
Q10: What routine maintenance is required in daily use?
A: Daily maintenance includes: checking air source pressure and emergency stop function before each shift; weekly cleaning of dust inside the enclosure and wiping the conductive sealing gasket; monthly inspection of fasteners and FRL drainage; quarterly verification of grounding resistance and shielding effectiveness testing; annual replacement of wear parts with comprehensive servicing.
8.4 Remote Control Intrinsic Shielding
Q11: For remote control PCB shielding covers, should nickel-silver alloy or nickel-plated brass be used?
A: Both have their advantages. Nickel-silver (German silver) offers superior conductivity, elasticity, and corrosion resistance, providing better shielding performance — ideal for one-piece spring-clip covers and premium products, though at a slightly higher cost. Nickel-plated brass delivers excellent solderability at moderate cost and is suitable for mass production with reflow soldering. For volume production of remote controls, nickel-plated brass is generally preferred, while nickel-silver is recommended when shielding requirements are demanding.
Q12: Why is the recommended ground via pitch on shielding covers 2–3mm?
A: The 2.4GHz wavelength is approximately 12.5cm, making λ/20 about 6mm. When via spacing is smaller than λ/20, gaps do not form resonances and shielding remains stable. The 2–3mm pitch provides ample margin to compensate for PCB layout deviations and soldering variations, ensuring consistent grounding performance across mass production.
Q13: How is the four-wire (Kelvin) method used to measure shielding cover grounding resistance, and what is the acceptance criterion?
A: The four-wire method, also known as the Kelvin method, uses a dedicated low-resistance tester with two wires carrying current and two wires sensing voltage, eliminating lead resistance effects. Test points are connected to the shielding cover body and the PCB ground plane respectively. The requirement is DC resistance <0.1Ω. Lower resistance indicates better grounding and more stable shielding performance.
8.5 Function Expansion
Q14: Can this shielding enclosure accommodate other remote control models?
A: Yes. Simply replace the corresponding positioning fixtures and probe modules — the enclosure body, pneumatic, electrical, and RF systems are fully universal. Fixture changes are quick and simple, completing in minutes, making the system ideal for multi-model production line testing.
Q15: Can the system be integrated into a production line for fully automated testing?
A: Yes, expansion is fully supported. Automatic loading/unloading mechanisms, barcode scanners, and defective product sorting modules can be added, with integration to customer MES systems for unmanned fully automated testing. We offer mature in-line shielding test solutions that can be customized to your requirements.
—
9. Construction Schedule Plan
| Phase No. | Work Phase | Main Activities | Duration (Days) | Responsible | Deliverables |
| — | — | — | — | — | — |
| 1 | Solution Confirmation | Requirements discussion, solution detailing, parameter confirmation, contract signing | 3 | Project Manager | Final solution document, contract |
| 2 | Production Preparation | Material procurement, drawing design, process planning, BOM confirmation | 5 | Production Supervisor | Production drawings, BOM |
| 3 | Manufacturing | Enclosure fabrication, sheet metal powder coating, accessory assembly, electrical wiring, tooling customization | 10 | Production Engineer | Semi-finished equipment |
| 4 | Factory Testing | Functional testing, shielding effectiveness testing, burn-in test, QC, packaging | 3 | QC Engineer | Factory inspection report, certificate of conformity |
| 5 | Logistics | Equipment packing, shipment, transit tracking | 2 | Logistics Specialist | Shipping documents, equipment in good condition |
| 6 | On-Site Installation | Equipment positioning, pneumatic connection, electrical connection, power-on trial | 1 | Installation Engineer | Installed equipment |
| 7 | Commissioning & Acceptance | Performance tuning, parameter calibration, operator training, customer acceptance | 2 | Technical Engineer | Acceptance report, training records |
| 8 | After-Sales Follow-up | Periodic visits, technical support, maintenance | Ongoing | After-Sales Specialist | Service records |
Total standard lead time: 26 days. Special customization requirements are subject to separate agreement.
—
10. Construction Organization Plan
10.1 Project Organization Structure
- Project Manager (1) : Oversees the entire project lifecycle, coordinates internal and external resources, controls schedule, quality, and cost, and serves as the customer interface.
- Technical Engineers (2) : Responsible for solution design, technical disclosure, on-site commissioning, and technical training.
- Installation Engineers (2) : Responsible for on-site installation, cabling, assembly, and basic commissioning.
- QC Engineer (1) : Responsible for factory inspection, on-site acceptance testing, and quality record archiving.
- After-Sales Specialist (1) : Responsible for post-delivery follow-up, fault response, and spare parts supply.
10.2 Pre-Construction Preparation
- Technical preparation: Complete construction drawings, work instructions, and inspection standards before work begins, with full technical disclosure. Verify site conditions and identify potential risks in advance.
- Material preparation: Complete full functional testing and shock-proof packaging before equipment leaves the factory, including certificate of conformity, instruction manuals, and inspection reports. Prepare installation tools, auxiliary materials, and PPE.
- Site preparation: Confirm equipment installation location, power supply point, and air source point in advance. Clear the area and reserve adequate operating space.
10.3 Construction Process
- Receiving inspection: Open-box inspection of equipment appearance and accessory quantities, confirming no transit damage, with both parties signing the receipt.
- Equipment positioning: Move equipment to the designated position, level and secure, confirming stable placement.
- Pneumatic connection: Connect air supply tubing, check airtightness, and regulate pressure to 0.5MPa.
- Electrical connection: Connect power, grounding, and communication cables, verifying correct wiring.
- Power-on trial: Power up each module sequentially, testing door opening/closing, press-down, alarm, and display functions.
- Performance commissioning: Calibrate shielding effectiveness, signal parameters, tooling positioning accuracy, and test data.
- Trial operation: Continuous no-load trial run for 2 hours, simulating the full test workflow to confirm stable operation.
- Acceptance & delivery: Customer on-site acceptance, signing of acceptance report, and delivery of complete documentation.
10.4 Quality Control
- Strict compliance with drawings and work instructions; every process undergoes a three-stage inspection: self-inspection, peer inspection, and dedicated inspection.
- Key performance indicators (shielding effectiveness, grounding resistance, pneumatic stability) are tested and recorded item by item, with data archived for traceability.
- All components are genuine parts from original manufacturers with corresponding certificates.
- Every unit undergoes a 48-hour burn-in aging test before shipment to ensure stability.
10.5 Safety and Civilized Construction
- All construction personnel wear appropriate PPE and comply with customer site safety regulations.
- Electrical work is performed with power disconnected, warning signs posted, and live wiring strictly prohibited.
- Pneumatic work requires pressure venting before servicing to prevent injury.
- Materials are stored neatly; the site is cleaned and restored to original condition after work completion.
- Fire extinguishing equipment is available on site to eliminate fire hazards.
—
11. After-Sales Service System
11.1 Warranty Service
- Warranty period: Full-machine warranty of 1 year, calculated from the date of acceptance.
- Warranty coverage: During the warranty period, equipment failures not caused by human damage or force majeure are repaired free of charge, including free replacement of parts.
- Exclusions: Wear parts (conductive sealing gaskets, test probes, button caps), improper operation, unauthorized modification, external physical damage, and force majeure are not covered under the free warranty.
11.2 Response Mechanism
- Technical consultation: Support hours and contact channel are confirmed on the quotation.
- Fault response: Initial solution provided within 30 minutes of a fault report; remotely resolvable issues handled within 2 hours.
- On-site service: For faults requiring on-site attention, engineer travel time is confirmed on the quotation.
11.3 Value-Added Services
- Lifetime maintenance: Lifetime maintenance at cost price after the warranty period — only spare parts and travel expenses are charged.
- Periodic visits: Quarterly telephone follow-ups and one free annual on-site inspection (optional) to proactively identify potential issues.
- Upgrade services: Equipment function upgrades, new tooling additions, and performance enhancement services available at cost price only.
- Spare parts: Spare-part availability and dispatch timing are confirmed on the quotation.
11.4 Service Commitment
- All after-sales services are provided by factory engineers with professional, reliable expertise.
- All replacement parts are genuine factory components with identical performance.
- Every service intervention is fully documented for quality traceability.
- Customer complaints receive a formal response within 24 hours.
—
12. Operation and Maintenance Training Plan
12.1 Training Objectives
Through systematic training, operators will be able to independently perform daily testing operations, maintenance personnel will be capable of routine maintenance and basic troubleshooting, and management staff will master equipment acceptance criteria and management procedures.
12.2 Training Audience
- Equipment operators: 2–3 personnel responsible for daily testing operations
- Equipment maintenance staff: 1–2 personnel responsible for routine maintenance and basic fault handling
- Technical management: 1 person responsible for equipment management and performance acceptance
12.3 Training Content
12.3.1 Theoretical Training (0.5 day)
- Fundamentals of electromagnetic shielding and 2.4GHz band characteristics
- Overall equipment architecture and operating principles of each subsystem
- Safety operating procedures and precautions
- Shielding performance indicators and testing methods
- Common fault identification and troubleshooting approaches
12.3.2 Hands-On Practical Training (1 day)
- Equipment power-on/off operating procedures
- Product placement and tooling change methods
- Pneumatic system adjustment and daily inspection
- Signal monitoring system parameter configuration and data export
- Video monitoring system operation and recording retrieval
- Complete test workflow practical exercise
- Basic troubleshooting and reset operations
12.3.3 Maintenance Training (0.5 day)
- Daily equipment cleaning and maintenance methods
- Conductive sealing gasket cleaning and replacement
- FRL unit draining and filter element replacement
- Periodic grounding resistance measurement methods
- Wear part replacement procedures
- Long-term storage precautions
12.4 Training Methodology
- On-site face-to-face instruction combining theory with hands-on practice
- Engineer demonstration followed by trainee practice with hands-on guidance
- Ample Q&A time allocated to address real operational issues
- Complete set of operation manuals, maintenance manuals, and training materials provided
12.5 Assessment Criteria
- Theoretical assessment: Written examination, passing score 80/100
- Practical assessment: Independent completion of a full test workflow with correct operating procedures and accurate results
- Trainees who do not pass receive complimentary retraining until competency is achieved
—
13. Representative Project Case Studies
Case Study 1: Batch Testing Project for Bathroom Heater Remote Controls — Leading Home Appliance Manufacturer
- Client background: A leading domestic bathroom heater manufacturer required 100% RF functional testing of 2.4GHz remote controls on their mass production line; the original manual testing approach was inefficient with poor consistency.
- Solution configuration: Customized 8-station automated shielding test enclosure with pneumatic automatic press-down, real-time signal monitoring, video surveillance system, and dedicated bathroom heater remote control positioning tooling.
- Results achieved: Single-enclosure testing efficiency increased by 6 times; test data consistency improved by 90%; labor costs reduced by 70%; equipment has operated reliably for over 2 years with zero major failures.
- Client feedback: Shielding performance meets requirements, equipment is stable and durable, production line testing efficiency greatly improved, and after-sales response is timely.
Case Study 2: R&D-Grade RF Test System for a Smart Home Enterprise
- Client background: A company focused on smart home product R&D requiring a high-precision shielding environment for product development, EMC pre-compliance testing, and competitive product analysis.
- Solution configuration: High-performance shielding enclosure with broadband absorber material, high-precision signal source and power meter, multi-channel test system, and accompanying test software.
- Results achieved: Shielding effectiveness reached 110dB @ 2.4GHz; test data correlation with third-party anechoic chamber results ≥95%; product R&D cycles significantly shortened.
- Client feedback: Exceptional test precision, comprehensive functionality, meeting all R&D-stage testing requirements, with professional and responsive technical support.
Case Study 3: In-Line Remote Control Test Workstation for a Consumer Electronics Manufacturer
- Client background: A large remote control contract manufacturer needed to integrate with an automated assembly line for unmanned in-line testing.
- Solution configuration: In-line shielding test workstation with automatic loading/unloading mechanism, automatic barcode scanning, automatic test sorting, and MES system integration.
- Results achieved: Test takt time of 8 seconds per unit; 24-hour continuous operation; automatic defective product sorting; fully traceable test data throughout the process.
- Client feedback: Seamless integration with the existing production line, high level of automation, and significant enhancement of production line intelligence.
—
14. SEO Optimization and Keyword Architecture
14.1 Keyword Classification
- Core primary keywords: 2.4G shielding enclosure, remote control shielding test system, automated shielding test enclosure, electromagnetic shielding enclosure, RF testing shielding enclosure
- High-conversion long-tail keywords: dedicated 2.4G remote control shielding enclosure, bathroom heater remote control test enclosure, batch remote control test system, pneumatic shielding enclosure manufacturer, remote control RF testing equipment, 8-station shielding test enclosure
- Industry traffic keywords: electromagnetic shielding test equipment, wireless product RF testing, EMC test shielding enclosure, industrial automated test equipment, RF shielding enclosure manufacturer, wireless remote control testing equipment
- Brand-specific keywords: KITOZER shielding enclosure, KITOZER shielding test system, KITOZER shielding equipment, Guangzhou Lain shielding equipment
- Related search keywords: shielding enclosure price, how to measure shielding effectiveness, what shielding enclosure for remote control testing, 2.4G shielding enclosure working principle, shielding enclosure manufacturer ranking, shielding enclosure daily maintenance
14.2 SEO Optimization Tags
- Core page optimization tags: 2.4G remote control shielding system, automated test shielding enclosure, RF testing solutions
- Title tag: 2.4G Remote Control Shielding System | Automated Test Shielding Enclosure | RF Testing Solutions — KITOZER
- Meta keywords: 2.4G shielding enclosure, remote control shielding test system, automated shielding test enclosure, electromagnetic shielding enclosure, RF testing equipment, KITOZER
Meta description: KITOZER is a professional manufacturer of 2.4GHz remote control shielding test systems and automated shielding test enclosures. Shielding effectiveness ≥100dB, batch testing capability, pneumatic control, real-time signal monitoring, custom tooling — project-confirmed quality assurance.
- H1 tag: 2.4GHz Remote Control Shielding System — Technical Design Solution
- H2 tags: Remote Control Intrinsic Shielding Design, Shielding Enclosure System Design, Pneumatic Drive System Design, RF Signal System Design, System Configuration List, Technical Parameter Specifications
14.3 Internal Link Anchor Text
- Core anchor text: shielding enclosure, remote control test system, automated testing equipment
- Long-tail anchor text: 2.4G RF shielding enclosure, bathroom heater remote control test fixture, electromagnetic shielding test solution
- Related anchor text: shielding room, integrated cabinet, cold aisle containment system, outdoor enclosure
—
Contact Us
Company: Guangzhou Lain Intelligent System Development Co., Ltd. (KITOZER)
Phone/WhatsApp/WeChat: +86 139 2228 9957 / +86 185 2066 8845
Website: https://gdlain.com
Address: Huashan Road 5, Shilou Town, Panyu District, Guangzhou, Guangdong, China