ToggleKITOZER KTR-B2300 2V300Ah Long-Life Gel Battery
Brand: KITOZER Series: KTR-B2300 Category: Power Distribution / UPS Backup
2V300Ahgel batterylong lifeVRLAUPS backup
1. Overview
KITOZER KTR-B2300 is a 2V300Ah long-life VRLA gel battery, the core energy storage for data center UPS and DC bus systems. On mains failure, the battery bank takes over within milliseconds, keeping servers, network gear and surveillance online. 2V cells are series-connected: 6 cells for 12 V, 12 for 24 V, 24 for 48 V, 104 for 220 V DC. The 300 Ah rating provides 15~30 minutes of backup for typical loads, bridging to diesel generator transfer. KTR-B2300 uses gelled electrolyte: silica gel immobilizes the acid into a thixotropic gel, so even a cracked case won’t leak — safe for data halls and enclosed spaces. Float design life is 15 years at 25℃, nearly double ordinary AGM (5~8 years).
Gel cells offer key advantages over flooded lead-acid: no leaks (VRLA sealed, no watering); strong deep-discharge recovery (after an 80% discharge, capacity recovers >95% on recharge, unlike flooded cells that degrade permanently after a few deep cycles); and better cold performance (reduced derating below 0℃). KTR-B2300 uses lead-calcium alloy grids, low self-discharge (<3%/month) and minimal water loss. Flame-retardant ABS case, UL94 V-0.
2V cells vs 12V blocks: lower per-cell voltage means more cells in series, so one weak cell has limited impact and can be replaced individually; high-rate discharge suits UPS short-duration high-power events. KTR-B2300 emphasizes long-life design — replacing an entire 104-cell bank is major work with downtime; a long-life cell costs more upfront but lowers total cost of ownership.
2. Key Features
Gel electrolyte
- Silica-gel immobilized acid, no leaks.
- Deep-discharge recovery >95%.
- -20℃ discharge capability.
Long-life design
- 15-year float life (25℃).
- Lead-calcium grids, <3%/month self-discharge.
- Minimal water loss, maintenance-free.
VRLA sealed safety
- No free acid, sealed valve-regulated.
- Pressure relief valve, explosion-safe.
- Flame-retardant ABS, UL94 V-0.
Power-system compatible
- Suits UPS, DC bus, EPS float service.
- Tin-plated copper terminals.
- Footprint fits standard racks.
3. Specifications
| Item | KTR-B2300 |
|---|---|
| Nominal voltage | 2 V |
| Rated capacity | 300 Ah (C10, 25℃) |
| Design life | 15 years (float, 25℃) |
| Electrolyte | Gel |
| Float voltage | 2.25 V/cell (25℃) |
| Equalize voltage | 2.35 V/cell (25℃) |
| Max discharge | 3000 A (5 min) |
| Self-discharge | <3%/month (25℃) |
| Operating temp | -20~55℃ |
| Case | FR ABS, UL94 V0 |
| Dimensions | 170×208×210 mm (W×D×H) |
| Weight | ~18 kg |
4. Reference Prices
KTR-B2300 2V300Ah gel long-life (15-year, VRLA, FR ABS): Reference USD 125~194 / cell (ref. CNY 900~1,400 at ~7.2)
KTR-B2300 complete bank (48 V, 24 cells, rack + links): Reference USD 3,056~4,861 / bank (ref. CNY 22,000~35,000 at ~7.2)
Reference only; priced by capacity, life grade and quantity. UPS and battery cabinet excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center UPS battery banks.
- Telecom 48 V DC plants.
- Substation DC control panels.
- Industrial UPS and EPS emergency power.
- Off-grid solar/wind storage.
6. Installation & Maintenance
Installation
- Level rack, verify load rating (~18 kg/cell).
- Arrange cells by number, clean terminals.
- Series links per polarity, torque to spec.
- Connect to UPS/charger.
- Commissioning charge/discharge activation test.
- Wire to battery monitoring (BMS).
Maintenance
- Monthly: per-cell voltage and temperature.
- Quarterly: internal resistance trend.
- Annual: capacity (discharge) test.
- Keep room at 20~25℃.
- Grease terminals annually.
7. FAQ
- Q: Gel vs AGM?
A: Gel lasts longer, recovers from deep discharge and handles cold better — ideal for unattended data halls. AGM is cheaper but shorter-lived. Choose gel for UPS. - Q: Why not 12V blocks?
A: 2V cells allow single-cell replacement and better high-rate discharge. A 12V block is six cells in one case — one bad cell kills the whole block. - Q: Can it really last 15 years?
A: 15 years is the float-life expectation at 25℃. Actual life halves for every 10℃ rise — keeping the room cool is critical. - Q: Why battery monitoring?
A: Weak cells always exist in a string; BMS tracks per-cell voltage and internal resistance to flag weak cells before a real outage.
8. Trend & Selection
Backup power evolves from lead-acid toward LiFePO4, but gel VRLA still dominates on cost, safety and supply maturity. Trend is long-life gel + BMS + DCIM integration. Select: 2V gel long-life for UPS; size with 20% margin; keep room ≤25℃; BMS mandatory; torque links to spec; annual capacity test.
9. Delivery & Service
KITOZER supplies battery banks: based on UPS capacity and required backup time, we calculate Ah and cell count, configure the 2V300Ah string, and produce the system and connection drawings. Bundled with UPS, battery cabinet and BMS. Delivery includes cells, links and terminal covers. Warranty covers capacity testing and weak-cell replacement.
10. Additional Notes
The most common install error: wrong link torque. Too loose → high resistance, heating, burned lugs; too tight → crushed terminal seal. Use a torque wrench per spec (typically 8~10 N·m for M8).
Another pitfall: “uncontrolled battery room temperature.” Many battery-room AC failures go unnoticed; summer temps above 35℃ halve battery life. Room temperature is the #1 life factor — the AC must be independent and reliable.
Selection summary: 2V300Ah gel; 15-year life; series count per system voltage; verify rack load; BMS monitoring; keep 25℃. The battery is the UPS fuel tank — with fuel in the tank, even a mains outage won’t bring servers down.