KITOZER
KITOZER

KITOZER KTR-ODS72 72-Port LC Fiber Distribution Frame (Full-Load ODF)

KITOZER KTR-ODS72 72-Port LC Fiber Distribution Frame (Full-Load ODF)

Brand: KITOZER Series: KTR-ODS72 Category: Optical Communication / Fiber Distribution Frame

72-port LCfull-load ODF19-inch racksplice trayKTR-ODS72

1. Overview

The KITOZER KTR-ODS72 is a 19-inch rack-mount fiber distribution frame (ODF) fully loaded with 72 LC duplex adapters (144 fibers), installed in standard 19-inch racks. The ODF is the patch hub between backbone and horizontal cabling: incoming outdoor/backbone cable is spliced to pigtails inside splice trays; the pigtail LC connector plugs into the adapter panel; patch cords then link to switch optical ports or horizontal cable.

KTR-ODS72 is 3U (133 mm) high, 19-inch (482 mm) wide, 250 mm deep. It holds 6 splice trays (12 fibers each), each with splice sleeves and excess-fiber storage. The front panel is detachable; 72 LC adapters in 3 rows (24 per row), LC duplex = 144 fibers. It includes cable management rings and fiber clamps, with patch cords exiting through the side. Slide-out design eases splicing and maintenance.

Typical uses: data center backbone patching, building telecom room cable termination, base station ODF, FTTH aggregation points. Full-load ODF ships with adapters and trays pre-installed — on site, only splice the cable, no field assembly needed.

2. Key Features

72-port full load

  • 72 LC duplex adapters.
  • 144 fibers.
  • 3 rows × 24 ports.
  • High LC density.

6 splice trays

  • 12 fibers per tray.
  • Splice sleeves.
  • Excess-fiber storage.
  • Slide-out trays.

19-inch 3U

  • 482×250×133 mm.
  • Cold-rolled steel powder coat.
  • Detachable front panel.
  • Slide-out maintenance.

Cable management

  • Side management rings.
  • Cable clamps.
  • Ground lead.
  • Label strip.

3. Specifications

Item Parameter
Model KTR-ODS72
Connector LC duplex
Port count 72 (144 fibers)
Splice trays 6 × 12 fibers
Form factor 19-inch rack 3U
Dimensions 482×250×133 mm (W×D×H)
Adapter LC MM/SM (option)
Panel material Cold-rolled steel powder coat
Slide-out manual slide
Mounting 19-inch rack square holes
Operating temp -10~60℃
Excess storage ≥1 m coil

4. Reference Prices

KTR-ODS72 72-port LC ODF (full-load, SM adapters):Ref. USD 83~167 / unit (CNY 600~1200 @7.2)

KTR-ODS72 72-port LC ODF (MM adapters):Ref. USD 69~139 / unit (CNY 500~1000 @7.2)

KTR-ODS72 empty chassis (no adapters/trays):Ref. USD 42~69 / unit (CNY 300~500 @7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data center backbone fiber patching.
  • Building telecom room cable termination.
  • Base station room ODF.
  • FTTH aggregation point.
  • Industrial fiber network patching.

6. Installation & Maintenance

Installation

  • Mount ODF in 19-inch rack U-position.
  • Secure front panel to square holes.
  • Feed backbone cable from rear.
  • Clamp cable, strip outer jacket.
  • Splice fibers in trays.
  • Coil excess fiber in tray storage.
  • Plug pigtail LC into front adapters.
  • Label port numbers on strip.

Maintenance

  • Check port labels monthly.
  • Clean patch cord end-faces quarterly.
  • Inspect splice tray excess storage.
  • Tighten cable clamps.
  • Test patch link loss.
  • Recap unused ports.

7. FAQ

  • Q:Full-load vs empty chassis?
    A:New projects choose full-load (pre-installed adapters + trays) — only splice on site, saves labor. Expansion or existing setups choose empty chassis and buy adapters/pigtails separately. Full-load costs slightly more but installs fast.
  • Q:LC vs SC adapters?
    A:LC is half the size of SC, higher density — suits data center high-density cabling (72 LC = 144 fibers). SC suits FTTH/building cabling (lower density). New data centers recommend LC.
  • Q:Splice vs mechanical (fast) connection?
    A:Splicing has low loss (≤0.1 dB), long-term stable — suits backbone cable long-term. Mechanical (cold) connects fast but higher loss (≤0.5 dB), ages faster — suits temporary cabling. Backbone in ODF: splice.
  • Q:Does 72-port ODF support MM or SM?
    A:Both — determined by adapter type. MM adapters (aqua) for OM3/OM4 short reach (≤300 m); SM adapters (blue) for long reach (>10 km). Specify fiber type when ordering.

8. Trend & Selection

Fiber ODFs are trending high-density (MTP/MPO pre-terminated), modular (replaceable adapter modules), and smart patching (RFID labels). In 40G/100G/400G cabling, MTP-LC conversion modules are common in ODFs, supporting fast pre-terminated cable deployment.

9. Delivery & Service

KITOZER sizes KTR-ODS72 by cable fiber count and connector type, providing port distribution diagrams and splice tray allocation. Delivery includes full-load ODF (adapters + trays + pigtails), mounting screws, certificate and manual. Warranty covers splice loss test guidance.

10. Additional Notes

A common pitfall is too-small bend radius. Fiber bend radius must be ≥30 mm (below 20 mm increases loss or breaks). Coil excess fiber in trays with proper curvature — do not kink.

Another pitfall is pulling patch cords hard. Insert/remove patch cords gently; fiber pull strength ≤5 N. Route excess cords through management rings — avoid hanging under tension.

Also verify pigtail length matches tray depth — too-long pigtails won’t fit, too-short ones won’t reach the adapter. Standard pigtails are 1.5 m; KTR-ODS72 trays accept up to 2 m excess comfortably.

Selection summary: 72-port LC full-load; 6 splice trays; 3U 19-inch; cold-rolled steel; slide-out. The ODF is the fiber network’s patching hub — clean splices, neat routing, clear labels keep the fiber link maintainable.