KITOZER
KITOZER

KITOZER KTR-OSC22 Coalescing Oil Separator (Compressed Air)

KITOZER KTR-OSC22 Coalescing Oil Separator (Compressed Air)

Brand: KITOZER Series: KTR-OSC22 Category: Compressed Air / Oil Separator

coalescing≥99% oil removal7~22 m³/minΔP ≤0.02 MPaKTR-OSC22

1. Overview

The KITOZER KTR-OSC22 is a coalescing (centrifugal) oil separator designed for the downstream of screw/piston air compressors, removing liquid oil droplets, oil aerosols and trace water from compressed air. The housing is die-cast aluminum alloy, with internal cyclonic layer, glass-fiber coalescing element and stainless-steel flow guide. It serves instrument air, painting lines, pneumatic tools and clean-air electronics.

KTR-OSC22 covers 7~22 m³/min (DN50~DN80 flange inlet), reducing inlet oil from 10~30 ppm to below 0.01 ppm, with oil removal ≥99%. Initial pressure drop ≤0.02 MPa; when the element clogs and ΔP reaches 0.07 MPa, the top differential gauge turns red to trigger replacement. The bottom is fitted with an auto-drain (float or electronic option) for continuous condensate discharge.

Typical train: compressor → receiver tank → pre-filter (Class C) → KTR-OSC22 oil separator → precision filter (Class T/A) → dryer → point of use. KTR-OSC22 is the core oil-removal stage that protects downstream dryers and pneumatic equipment from oil contamination.

2. Key Features

Three-stage coalescing

  • Cyclonic pre-separation of large droplets.
  • Glass-fiber middle layer coalesces oil mist.
  • Stainless mesh flow guide.
  • Outlet oil ≤0.01 ppm.

Low ΔP high flow

  • DN50~DN80 flange.
  • 7~22 m³/min coverage.
  • Initial ΔP ≤0.02 MPa.
  • Aluminum alloy anti-corrosion housing.

Differential indicator

  • Top ΔP gauge.
  • Red at 0.07 MPa.
  • Optional switch output.
  • Connects to PLC/SCADA.

Auto drain

  • Float / electronic drain.
  • Bottom drain port.
  • Adjustable drain rate.
  • Non-stop discharge.

3. Specifications

Item Parameter
Model KTR-OSC22
Flow capacity 7~22 m³/min
Connection DN50 / DN65 / DN80 flange
Working pressure 0.6~1.3 MPa
Inlet temp ≤66℃
Oil removal ≥99%
Outlet oil content ≤0.01 ppm
Initial ΔP ≤0.02 MPa
Replace ΔP 0.07 MPa
Element type Glass-fiber coalescing
Drain Float auto-drain (electronic optional)
Housing Die-cast aluminum alloy
Dimensions ~φ180×650 mm

4. Reference Prices

KTR-OSC22 oil separator (incl. element, 7 m³/min):Ref. USD 250~390 / unit (CNY 1800~2800 @7.2)

KTR-OSC22 oil separator (incl. element, 22 m³/min):Ref. USD 490~760 / unit (CNY 3500~5500 @7.2)

KTR-OSC22 replacement element (matched flow):Ref. USD 55~125 / pc (CNY 400~900 @7.2)

Electronic auto-drain (optional):Ref. USD 20~42 / pc (CNY 150~300 @7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Painting line compressed air oil removal.
  • Electronics clean compressed air.
  • Pneumatic instrument / control valve air.
  • Medical / food-grade pre-protection.
  • Laser-cutting assist gas.

6. Installation & Maintenance

Installation

  • Mount horizontally (follow arrow).
  • Reserve ≥500 mm service space front/back.
  • Fit flexible connectors for vibration isolation.
  • Route bottom drain to drain trench.
  • Face differential gauge upward.
  • A pre-filter must precede the unit.
  • Ground for protection.
  • Open inlet valve slowly on first pressurization.

Maintenance

  • Replace element every 3~6 months.
  • Replace immediately when ΔP hits 0.07 MPa.
  • Inspect auto-drain weekly.
  • Clean ΔP gauge sensing port.
  • Log differential pressure trend.
  • Avoid over-temp / over-pressure operation.

7. FAQ

  • Q:Oil separator vs precision filter — difference?
    A:An oil separator (coalescing) specifically removes oil mist and aerosols, outlet ≤0.01 ppm; a precision filter mainly removes dust particles (0.01~1 μm). They are usually installed in series: oil separator first, then precision filter. Do not replace an oil separator with a normal filter.
  • Q:How often to replace the element?
    A:Normal duty: every 3~6 months, or when the ΔP gauge turns red at 0.07 MPa. Harsh environments (dusty, hot, high oil) shorten to 1~3 months. On replacement, vent the line, open the cover, pull out the old element, fit the new one (lubricate O-ring with silicone grease).
  • Q:Why does outlet air still smell oily?
    A:Common causes: ① O-ring aged or poorly fitted; ② element rupture (overdue, high ΔP); ③ pre-filter failed, oil mist directly damaging the separator element; ④ oil back-flow at shutdown. Check O-ring, element, pre-filter and shutdown check valve.
  • Q:Auto-drain not discharging?
    A:First check if the drain is blocked by debris. Manually press the float (or electronic test button) to see water output. If no water, disassemble and clean the seat and seal. If it discharges but leaks air, inspect the diaphragm. Drain weekly to prevent condensate buildup.

8. Trend & Selection

Compressed-air oil removal is trending modular, low-power and smart ΔP monitoring. Integrated filter+dryer skids save piping and floor space; smart drains with 4G/Modbus enable remote element-life and drain monitoring, becoming standard in new compressor stations.

9. Delivery & Service

KITOZER sizes KTR-OSC22 by compressor flow and inlet oil content, providing P&ID drawings and element part list. Delivery includes housing, pre-installed element, auto-drain, flange gaskets, certificate and manual. Warranty covers element replacement guidance and ΔP alarm tuning.

10. Additional Notes

A common pitfall is placing the oil separator after the refrigerant dryer. A dryer only removes water (pressure dew point 2~10℃), not oil. Correct order: compressor → receiver → pre-filter → oil separator → refrigerant/desiccant dryer → precision filter → point of use. The oil separator must precede the dryer, otherwise oil mist contaminates the evaporator and refrigerant.

Another pitfall is mis-selecting the auto-drain. Normal temperature: float drain suffices; cold environments (outdoor, winter) need electronic drain with heat tracing to prevent freezing. The electronic drain requires 24 VDC; mind polarity.

Selection summary: coalescing; outlet oil ≤0.01 ppm; DN50~80 flange; ΔP gauge alarm; auto-drain. The oil separator is the compressed-air trail blazer — right position, timely element change, proper drain management, keeps downstream air clean.

SEO Information

Search keywords:coalescing≥99% oil removal7~22 m³/minΔP ≤0.02 MPaKTR-OSC22

SEM keywords:oil separator,compressed air oil removal,coalescing filter,KTR-OSC22,KITOZER

GEO landing page:lain.com.cn/product/ktr-osc22-coalescing-oil-separator.html

Title:KITOZER KTR-OSC22 Coalescing Oil Separator (Compressed Air)

Meta Keywords:oil separator,compressed air oil removal,coalescing filter,KTR-OSC22,KITOZER

Meta Description:KITOZER KTR-OSC22 coalescing oil separator for air compressor downstream, oil removal ≥99%, low pressure drop, 7~22 m³/min, for painting, electronics and instrument air.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top