ToggleKITOZER KTR-CA-FAN-2U Rack Fan Unit (6 fans, 2U, thermostatic)
Brand: KITOZER Series: KTR-CA-FAN-2U Category: Rack Accessory / Top Fan Tray
6 fans2Uthermostatic~600m3/hKTR-CA-FAN-2U
1. Overview
The KITOZER KTR-CA-FAN-2U is a fan tray mounted at the top (or upper section) of a network cabinet. It actively exhausts hot air heated by internal equipment, creating negative pressure so cool room air is drawn in through the bottom cable gland / ventilated floor, forming a bottom-in / top-out convection path. A network cabinet holds switches, routers, servers and UPS; with the door closed and no air movement, heat builds up and internal temperature can exceed 50 C (equipment is typically rated to 40 C), causing over-temperature shutdown and shortened capacitor life. KTR-CA-FAN-2U sits at the top and six 120 mm axial fans pull hot air out; cool air enters at the bottom. A thermostatic controller ramps fan speed up when temperature rises, keeping noise low when cool.
Specs: standard 2U (about 88 mm); six 120x120x38 mm axial fans; each fan about 100 m3/h, total about 600 m3/h; fan noise about 38 dB(A) each, about 55 dB(A) at full speed; power AC220 V (standard; DC48 V optional); built-in temperature sensor and speed board (start about 35 C, full speed about 45 C); painted steel body; fits 600×600 / 600×800 standard cabinets; power switch and LEDs; each fan is field-replaceable. It belongs to the same rack-accessory family as item 851 (sliding shelf) and 843 (cable ring), but this is an active cooling component.
Typical uses: weak-current cabinets (switches, routers, ODF); small/medium business rooms with single racks; outdoor cabinets (supplementary ventilation with AC or heat exchanger); exhibition / office building weak-current rooms; base-station cabinets; edge-computing racks. If the cabinet already uses precision or in-row cooling, top fans are usually unnecessary (the AC already does bottom supply / top return). Add KTR-CA-FAN-2U only when natural convection is insufficient and internal temperature alarms appear.
2. Key Features
Six fans, high airflow
- Six 120 mm axial fans.
- Total airflow about 600 m3/h.
- Top exhaust creates negative pressure.
- Bottom-in / top-out path.
Thermostatic speed
- Built-in temperature sensor.
- Off or low below 35 C.
- Linear ramp 35 to 45 C.
- Full speed above 45 C.
Standard 2U
- 2U (about 88 mm) rackmount.
- Mounts on 19-inch square-hole rails.
- Fits 600 mm wide cabinets.
- Plug and play.
Easy service
- Each fan swappable individually.
- Power switch.
- LED power / fault indicators.
- Painted steel body.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-CA-FAN-2U |
| Type | Rack-top fan tray |
| Height | 2U (about 88 mm) |
| Fans | Six 120 mm axial |
| Per-fan airflow | about 100 m3/h |
| Total airflow | about 600 m3/h |
| Fan noise | about 38 dB(A) each |
| Full-speed noise | about 55 dB(A) |
| Power | AC220 V (std) / DC48 V optional |
| Speed control | Auto by temp sensor |
| Start temp | about 35 C |
| Full-speed temp | about 45 C |
| Body | Painted cold-rolled steel |
| Cabinet | 600×600 / 600×800 19-inch |
| Size | about 480x220x88 mm |
4. Reference Prices
KTR-CA-FAN-2U 6-fan (thermostatic, AC220V): Ref. USD 63~90 / pc (CNY 450~650 at 7.2)
KTR-CA-FAN-1U 3-fan (1U small cabinet): Ref. USD 39~56 / pc (CNY 280~400 at 7.2)
KTR-CA-FAN-3U 9-fan (high-power rack): Ref. USD 90~125 / pc (CNY 650~900 at 7.2)
KTR-CA-FAN-2U-48V DC48V (base station): Ref. USD 76~108 / pc (CNY 550~780 at 7.2)
Spare fan (120mm, AC220V): Ref. USD 5~8 / pc (CNY 35~55 at 7.2)
Sensor probe extension (3m): Ref. USD 2~3.5 / pc (CNY 15~25 at 7.2)
Reference only; 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Weak-current cabinet switch cooling.
- Small/medium business single racks.
- Outdoor cabinet supplementary cooling.
- Exhibition / office weak-current rooms.
- 5G base-station cabinets.
- Edge-computing nodes.
6. Installation & Maintenance
Installation
- Mount at the very top 2U (heat rises; top exhaust is most effective).
- Fix to 19-inch square-hole rails with M6 cage nuts.
- Confirm airflow points up (exhaust out of cabinet, not in).
- Wire AC220 V to the cabinet PDU.
- Place the temp probe mid-cabinet (represents equipment inlet air).
- Do not tape the probe to the wall (wall runs hot and triggers falsely).
- Power on; fans spin and LEDs light.
- Measure mid-cabinet temp with a hygrometer to verify cooling.
Maintenance
- Quarterly clean the intake (dust drops airflow).
- Annually listen for bearing noise (3 to 5 year fan life).
- Replace a dead or noisy fan with a standard 120 mm unit.
- Check that the probe is still fixed.
- In winter the fan may stay off (normal thermostatic stop).
- If summer mid-rack temp still exceeds 40 C, add AC or another fan tray.
7. FAQ
- Q:Fan tray vs rack AC?
A:Depends on heat load and ambient. Internal load under 1 kW with room ambient under 30 C: KTR-CA-FAN-2U exhausts cabinet heat into the room and room AC handles it. Load 1 to 3 kW or summer ambient above 35 C: use a rack AC (independent cooling, not dependent on room AC). Outdoor or sealed cabinets (cannot open the door) need AC or a heat exchanger; a fan draws in hot outdoor air and makes it worse. - Q:Why is the rack still hot after the fan?
A:Three common causes. (1) Door left open – the fan pulls air from everywhere and does not form cabinet convection. (2) Bottom intake blocked by cables – cool air cannot enter. (3) Fan blows inward (reversed) – it pushes hot air onto equipment. Keep the door closed, leave bottom intake space, and exhaust outward. - Q:Is six fans noisy?
A:Full speed in summer is about 55 dB(A) (normal conversation) – acceptable in an open weak-current room but noticeable in a quiet office or library. Thermostatic low speed in winter is about 35 dB, nearly silent. For noise-sensitive rooms choose the DC48 V version (quieter) or run fans on a slower speed. - Q:How many trays per rack?
A:One top fan tray (600 m3/h) handles a 600×800 rack with about 1 to 2 kW. If the rack holds four or five 1U servers at 500 W each (2.5 kW+), use two trays (top and middle) or switch to in-row cooling. Do not overload; fan cooling has a ceiling beyond which it is just a fan on an oven.
8. Trend & Selection
Rack cooling moves from passive convection to active fan trays, then to rack AC and liquid cooling. Fan trays move from fixed-speed to PWM thermostatic control for energy and noise. They move from single fans to modular blower trays with online fan replacement. Smart trays with RS485 reporting (per-fan RPM, fault, rack temp) become standard in data centers. They work with cold-aisle containment and in-row AC for fine-grained cooling.
9. Delivery & Service
KITOZER sizes KTR-CA-FAN-2U by cabinet size and internal heat load, providing airflow calculations and top-mount guidance. Delivery includes the fan tray, M6 screw kit, temp probe, power cord, manual and certificate. Warranty covers fan replacement and thermostatic tuning.
10. Additional Notes
A common pitfall is blowing inward. The airflow arrow is on the fan side; reversed installation pushes hot air onto equipment and makes things worse. Mount with the arrow pointing out (up).
Another pitfall is taping the probe to the cabinet wall. In summer the wall is hot, the probe reads 50 C, and fans run at full speed for no reason when mid-rack equipment inlet is only 35 C. Hang the probe mid-rack, representing real equipment inlet air.
Selection summary: 2U; six fans; 600 m3/h; thermostatic; AC220 V. The fan tray is standard for standalone rack cooling; the keys are top exhaust, closed door with bottom intake, and a mid-rack probe.
Extra tip: do not fight bottom-supply AC. If the rack sits in a cold-aisle containment (AC supplies underfloor air to the rack front), a top fan tray disrupts the air path. In that case exhaust fans only in the hot aisle, or rely on in-row AC.