ToggleKITOZER KTR-FD-ODF-48LC 48-Port LC Fiber ODF (2U, fully loaded)
Brand: KITOZER Series: KTR-FD-ODF-48LC Category: Fiber Distribution / 48-Port LC Rack ODF
48x LC2Uloadedsplice traysKTR-FD-ODF-48LC
1. Overview
The KITOZER KTR-FD-ODF-48LC is a 2U rackmount optical distribution frame (ODF) installed in a 19-inch cabinet. The back side fuses incoming outdoor/riser cables, and the front side breaks them out over 48 LC adapters (48 fibers; or 24 LC duplex ports = 48 fibers) to patch cords running to switches and servers. It is the fiber cross-connect: the 24- or 48-fiber incoming cable is fusion-spliced to pigtails inside, the pigtails are coiled in splice trays, the pigtail LC plugs go into the front adapters, and patch cords on the front run to equipment. Compared with item 847 (24-port SC ODF) and item 855 (wall-mount 12-core LC box), KTR-FD-ODF-48LC is the high-density rack version: 2U for 48 LC fibers, double the density of the SC ODF, for in-rack trunk termination in data centers.
Specs: standard 19-inch 2U (about 88 mm); 482 mm wide; loaded with 48 LC simplex adapters (single-mode, or OM3 multimode); three built-in splice trays (12 fibers each); painted cold-rolled steel; lockable front cover; rear cable entry and gland; cable management ring; adapter type selectable (LC/SC/FC); single-mode (yellow patch cords) or OM3 multimode (aqua patch cords). The loaded version ships with adapters and trays and is ready to splice; the blank version (frame only, adapters added later) is about 30% cheaper.
Typical uses: in-rack trunk termination in data centers; vertical riser patching in building weak-current rooms; carrier-room ODF racks; enterprise core switch fiber patching; campus aggregation. One cabinet typically holds 2 to 4 KTR-FD-ODF-48LC units, terminating trunks from different directions (uplink, server zone, storage zone). It pairs with item 858 (MPO adapters): trunks run on MPO, mate on MPO adapters inside the ODF, and MPO-LC breakout fan-out cords run to the 48-LC front.
2. Key Features
48-port density
- 48 LC fibers in 2U.
- 2x the density of SC ODF.
- Loaded adapters, plug-and-play.
- Saves rack U.
Pull-out splice trays
- Three 12-fiber trays.
- Pull out for splicing.
- Pigtails coiled neatly.
- Bend radius >=30 mm.
Adapter options
- LC simplex / LC duplex.
- SC simplex / SC duplex.
- FC / ST available.
- SM OS2 / OM3 / OM4.
Metal frame
- Painted cold-rolled steel.
- Lockable front panel.
- Cable management ring.
- 19-inch standard.
3. Specifications
| Item | Parameter |
|---|---|
| Model | KTR-FD-ODF-48LC |
| Type | Rackmount fiber distribution frame |
| Height | 2U (about 88 mm) |
| Width | 19-inch (482 mm) |
| Ports | 48 LC simplex (48 fibers) |
| Adapters | Loaded LC (SC/FC optional) |
| Splice trays | 3 x 12-fiber |
| Fiber type | SM OS2 / MM OM3 selectable |
| Insertion loss | <=0.3 dB (adapter) |
| Bend radius | >=30 mm (pigtail) |
| Frame | Painted cold-rolled steel |
| Front cover | Lockable |
| Management | Cable ring included |
| Mounting | 19-inch square-hole rails |
4. Reference Prices
KTR-FD-ODF-48LC 2U loaded (48x LC SM): Ref. USD 63~90 / pc (CNY 450~650 at 7.2)
KTR-FD-ODF-48LC-MM OM3 version: Ref. USD 70~97 / pc (CNY 500~700 at 7.2)
KTR-FD-ODF-24LC 24-port 1U (smaller): Ref. USD 39~56 / pc (CNY 280~400 at 7.2)
KTR-FD-ODF-96LC 96-port 4U (large): Ref. USD 110~155 / pc (CNY 800~1100 at 7.2)
KTR-FD-ODF-48LC-BLANK frame only: Ref. USD 39~53 / pc (CNY 280~380 at 7.2)
LC-LC SM patch cord (3m): Ref. USD 2~3.5 / pc (CNY 15~25 at 7.2)
Reference only; 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Data center in-rack trunk termination.
- Building riser patching.
- Carrier-room ODF racks.
- Enterprise core switch patching.
- Campus aggregation.
- Industrial control room fiber patching.
6. Installation & Maintenance
Installation
- Fix the ODF to 19-inch rails with M6 cage nuts.
- Bring the cable in from the rear; gland the armor.
- Strip the jacket; route 24/48 fibers to splice trays.
- Fusion-splice each fiber to a pigtail (loss <=0.05 dB).
- Shrink the splice protector and seat it in the tray slot.
- Coil pigtails with >=30 mm bend radius.
- Plug pigtail LC ends into the front adapters.
- Patch cords on the front run to switches.
- Label every fiber.
Maintenance
- Clean end-faces before mating.
- Do not pull patch cords (tension <=5 kg).
- Quarterly check labels.
- Do not pull splice trays out repeatedly (vibration stresses splices).
- Use a dedicated cleaning stick for dirty end-faces.
- Do not stack weight on the ODF.
7. FAQ
- Q:Is 48 LC ports 48 fibers or 24?
A:KTR-FD-ODF-48LC has 48 LC simplex adapters, i.e. 48 fibers (one per port). If using LC duplex adapters (one port accepts an LC duplex plug carrying RX+TX), 48 ports = 96 fibers. State which when ordering: simplex version 48 ports = 48 fibers; duplex version 48 ports = 96 fibers. Data centers now favor LC duplex (each port carries bidirectional traffic), so a 48-port duplex ODF is really 96 fibers. - Q:Loaded vs blank frame?
A:Loaded (this model, 450 to 650 RMB) includes 48 LC adapters and three splice trays, ready to splice. Blank (280 to 380 RMB) is just the frame; adapters (about 15 RMB each x 48 = 720 RMB) and trays (about 30 RMB each x 3 = 90 RMB) are added separately, which ends up more expensive. Unless you need unusual adapter types (FC/ST), buy the loaded version. - Q:SM vs MM?
A:Inside a building / data center (distance <=300 m) use OM3 multimode (aqua cords, cheap, supports 10G). Between buildings / campus (over 300 m) use single-mode OS2 (yellow cords). Do not mix: a SM cord in a MM adapter (or vice versa) has high loss even though it physically fits. New data centers run SM trunks and OMMM branches to servers. - Q:How many ODFs per rack?
A:By fiber count. A rack with 24 10G uplinks needs 24 fibers uplink plus 24 to servers = 48 fibers, so one KTR-FD-ODF-48LC is enough. A high-density server rack (20 servers with dual ports = 40 fibers, plus 48 uplink = 88 fibers) needs two ODFs (2U x 2 = 4U). Do not fill to 100%; keep 20% spare.
8. Trend & Selection
ODFs move from field-spliced to pre-terminated (factory-pretruded trunk cables with MPO modules, plug-and-play on site, no fusion). They move from LC simplex to high-density MPO cassettes (1U = 144 fibers). They move from blank frames with field splicing to modular MPO-trunk + LC-branch cassettes, cutting deployment 5x. Smart patching (electronic port IDs like RJ45) becomes standard for auto port management in data centers.
9. Delivery & Service
KITOZER sizes KTR-FD-ODF-48LC by rack fiber count, providing the adapter and splice-tray configuration list. Delivery includes the frame, loaded adapters, splice trays, M6 screw kit, manual and certificate. Warranty covers splicing guidance and label management.
10. Additional Notes
A common pitfall is coiling pigtails too tight. A bend radius under 30 mm creates large macrobend loss, adding 0.5 dB or more. Coil pigtails in large loops inside the tray, never sharp corners.
Another pitfall is skipping labels. 48 fibers in one ODF, unlabeled; after three months nobody knows which is which. Label immediately after splicing (one label per fiber on the rear tray, one per port on the front). Use printed labels (handwritten fades).
Selection summary: 2U; 48 LC; loaded adapters; 3 splice trays; SM/OM3. The ODF is the trunk termination core; the keys are large pigtail coils, clean end-faces, and clear labels.
Extra tip: mount the ODF mid-rack, not at the very top (patch cords hang too far) or very bottom (awkward to reach switches). Usually mount at the top above the switches so patch cords drop straight down to them.