Table of Contents
ToggleKITOZER KTR-VAC-OM Vacuum Pump Oil Mist Separator (Exhaust Filtration)
Brand: KITOZER Series: KTR-VAC-OM Category: Vacuum Equipment / Oil Mist Separation
Vane Pump99.9%Glass FiberReplaceable CartridgeKTR-VAC-OM
1. Overview
When a rotary vane vacuum pump runs, the pump oil is atomized by the high-speed exhaust stream and exits as a visible blue oil mist. This mist settles on equipment, floors and operators, wasting oil, fouling the workshop, and being unhealthy to breathe. The KITOZER KTR-VAC-OM is plumbed onto the pump exhaust. A multi-layer glass-fiber media intercepts the oil droplets; the droplets coalesce and drain back into the pump reservoir, while clean air is vented to the room or a central duct.
Key specs: fits single- and two-stage rotary vane pumps, pumping speed 4~100 m3/h; glass-fiber composite media, 0.1 micron; separation efficiency >=99.9%; initial pressure drop <=20 mbar; operating -10 to +120 C; die-cast aluminum powder-coated housing; inlet/outlet as clamp or G1/G1 thread; replaceable cartridge; size matched to the pump.
Typical use: a 2X-8 vane pump (8 m3/h) vents into a KTR-VAC-OM-8, whose outlet feeds a metal hose to the workshop exhaust duct. After three months the cartridge is opened and the paper is caked with tan sludge, proving capture. Oil top-up dropped from 2 liters/month to 0.3 liters because most oil drains back.
2. Key Features
99.9% high efficiency
- Deep-bed glass fiber media.
- 0.1 micron capture.
- Droplet coalescence and return.
- Visible exhaust mist gone.
Low pressure drop
- Initial drop <=20 mbar.
- No loss of pumping speed.
- Dust-holding capacity.
- Replace at 80 mbar.
Quick-clamp connections
- Tri-clamp inlet/outlet.
- 30-second cartridge swap.
- Tool-less canister opening.
- Silicone O-ring seal.
Aluminum housing
- Die-cast aluminum.
- Powder-coated anti-corrosion.
- Bottom check-valve oil return.
- Wall or pipe-mount.
3. Specifications
| Item | Value |
|---|---|
| Model | KTR-VAC-OM-8 / OM-16 / OM-40 / OM-100 |
| Pumping speed | 8 / 16 / 40 / 100 m3/h |
| Media | Multi-layer glass fiber paper |
| Rating | 0.1 micron |
| Efficiency | >=99.9% |
| Initial drop | <=20 mbar |
| Replace at | 80 mbar |
| Operating temp | -10 to +120 C |
| Ports | Tri-clamp / G1 / G1-1/4 |
| Housing | Die-cast aluminum, powder coat |
| Oil return | Bottom check valve, auto return |
| Seal | Silicone O-ring |
| Mounting | In-line or wall bracket |
4. Reference Price
KTR-VAC-OM-8 (8 m3/h): RMB 320~450 / unit (about USD 44~63)
KTR-VAC-OM-16 (16 m3/h): RMB 480~680 / unit (about USD 67~94)
KTR-VAC-OM-40 (40 m3/h): RMB 780~1100 / unit (about USD 108~153)
KTR-VAC-OM-100 (100 m3/h): RMB 1500~2200 / unit (about USD 208~306)
Spare cartridges (all sizes): RMB 80~260 / pc (about USD 11~36)
Metal hose (1 m): RMB 45~80 / pc (about USD 6~11)
Reference prices only; final price subject to quotation. (1 USD ≈ 7.2 CNY)
5. Applications
- Food vacuum packaging machines.
- Electronics/semiconductor vacuum chucks.
- Lab freeze dryers and rotary evaporators.
- Printing press paper suction.
- CNC vacuum workholding.
- Chemical distillation and degassing.
- Central pump room exhaust headers.
6. Installation & Maintenance
Installation
- Match the separator size to the pump speed.
- Stop and lock out the pump; remove the stock muffler.
- Clamp the separator inlet to the pump exhaust.
- Run a metal hose from the outlet to the duct.
- Connect the bottom return line to the pump fill port (or a drain cup).
- Mount the separator vertically, return port down; never upside-down.
- Check clamps and O-rings.
- Start the pump; listen for leaks and feel for mist at the outlet.
Maintenance
- Check the drain cup monthly; collected oil means capture is working.
- Replace the cartridge every 3 months or at 80 mbar.
- Wipe the housing and O-ring during cartridge swaps.
- Dispose used cartridges as oily waste; do not litter.
- Do not let the return line block, or oil blows out the exhaust.
- In winter, idle 5 min under no load before loading so oil warms and drains.
- Inspect clamps and hose aging every six months.
- Do not blow out cartridges and reuse (glass fiber tears).
7. FAQ
- Q:Still see mist after installing?
A:Check the cartridge for reversal or a missing O-ring. Then check pressure drop (clogged = replace). If a new cartridge still emits mist, the pump oil level is too high above the sight glass center — lower it. An over-long or kinked exhaust hose can also back-pressure and blow oil. - Q:How often to change the cartridge?
A:Depends on duty. 8 h/day continuous = 3~6 months; intermittent = 6~12 months. Signs: exhaust pressure rises, pumping slows, or mist reappears. A differential gauge at 80 mbar is the reliable trigger. - Q:Must the return line go back to the pump?
A:Not mandatory. Small pumps can drain to a cup you empty periodically. Large pumps should return to the reservoir to save oil. Add a check valve on the return so pump air does not blow oil back into the separator when shut down. - Q:Can several pumps share one separator?
A:No. Exhaust pulses differ between pumps; sharing cross-contaminates and one pump can back-feed oil into another. For central exhaust, fit a small primary separator on each pump and a central mist filter on the header.
8. Industry Trends & Selection
Oil-mist separation is moving from single exhaust filtration to integrated inlet filter + oil separation + exhaust silencer modules. Media is upgrading from paper to nano-glass-fiber coalescence layers, pushing efficiency from 95% to 99.99%. Smart separators with differential-pressure transmitters report cartridge life to a BMS for early replacement. Oil-free pumps (scroll, screw, dry claw) are rising, but vane pumps still dominate small-to-medium low-cost duties, so mist separation stays relevant. Select by pump speed; choose standard or high-efficiency by emission rules; horizontal or vertical by space. Food and pharma shops prefer high-efficiency with a 304 stainless housing.
9. Delivery & Service
KITOZER matches KTR-VAC-OM units to the user’s pump model and speed, and provides flange drawings and return-line advice. Delivery includes separator, spare O-ring set, one spare cartridge, manual and certificate. One free cartridge replacement is covered under warranty for non-user damage.
10. Notes
A common pitfall is mounting the separator upside-down or horizontally. Mist separators rely on gravity to drain coalesced droplets; upside-down, droplets fall onto the inlet side of the media, clogging it fast and raising back-pressure. Keep it vertical, drain port at the bottom.
Another pitfall is reusing a blown-out cartridge. Glass-fiber depth media traps dust inside the fibers; blowing from the outside cannot remove it and tears the paper, letting mist pass straight through. Replace at the rated pressure drop.
Selection summary: match by speed; glass fiber; 99.9%; vertical mount; swap cartridge on schedule. The oil-mist separator is the pump room’s fume cleaner; keys are correct size, correct orientation, and timely cartridge swaps.
Tip: a new separator may smoke lightly on first start-up — residual drying oil on the paper, which clears in half an hour. If it persists, check cartridge sealing and oil level.
SEO
Contact Us
KITOZER brand (professional data-center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com