KITOZER KTR-SPD-AC40 AC Power SPD (Type-2 Surge, 40kA, DIN Rail)

KITOZER KTR-SPD-AC40 AC Power SPD (Type-2 Surge, 40kA, DIN Rail)

Brand: KITOZER Series: KTR-SPD-AC40 Category: Lightning Protection / AC SPD

40kAType-2DIN RailRemote AlarmKTR-SPD-AC40

1. Overview

Lightning surges and grid switching transients travel in on the power lines and can instantly destroy switch, UPS and server boards. A surge protective device (SPD) is paralleled across the distribution busbar: normally it is high-impedance and does nothing; when the surge voltage exceeds the varistor threshold, it clamps in nanoseconds and dumps the surge current to earth. The KITOZER KTR-SPD-AC40 is a type-2 AC SPD, 40kA (8/20us), installed at the room distribution board or UPS input as the middle stage of a three-level protection scheme.

Key specs: nominal discharge In=20kA (8/20us); max discharge Imax=40kA (8/20us); Uc=385 VAC; voltage protection level Up<=1.8 kV; response <=25 ns; 35mm DIN-rail plug-in module; 1P+N or 3P+N; optional dry-contact remote alarm; failure window green=OK / red=failed; -40 to +85 C; UL94V-0 housing; replace the module only, no rewiring.

Typical use: room main busbar gets a type-1 SPD (80kA); the UPS input gets a KTR-SPD-AC40 type-2; equipment outlets get type-3 surge strips. The type-2 remote-contact wires to the DCIM host; when the SPD window turns red, the system alarms for module replacement.

2. Key Features

40kA high discharge

  • Imax=40kA (8/20us).
  • In=20kA.
  • Varistor + gas tube combo.
  • Suits type-2 distribution.

Plug-in module

  • 35mm DIN-rail base.
  • Swap module on failure.
  • Hot-swap without rewiring.
  • Base wiring stays put.

Window + remote

  • Green window = OK.
  • Red window = failed.
  • Dry-contact remote alarm.
  • Wired to DCIM.

Low residual voltage

  • Up<=1.8 kV.
  • Downstream devices safe.
  • Response <=25 ns.
  • Nanosecond clamping.

3. Specifications

Item Value
Model KTR-SPD-AC40
Class Type-2 (Class C) AC SPD
Nominal In 20kA (8/20us)
Max Imax 40kA (8/20us)
Uc 385 VAC
Up <=1.8 kV
Response time <=25 ns
Poles 1P+N / 3P+N
Remote alarm Dry contact (optional)
Indicator Green OK / Red failed
Mounting 35mm DIN-rail plug-in
Operating temp -40 to +85 C
Housing UL94V-0 flame-retardant

4. Reference Price

KTR-SPD-AC40 1P+N single-phase: RMB 120~180 / set (about USD 17~25)

KTR-SPD-AC40 3P+N three-phase: RMB 280~420 / set (about USD 39~58)

KTR-SPD-AC80 80kA type-1: RMB 450~680 / set (about USD 63~94)

KTR-SPD-AC10 10kA outlet strip: RMB 45~70 / pc (about USD 6~10)

Remote alarm module: RMB 25~40 / pc (about USD 3~6)

SPD backup protector (SCB): RMB 80~130 / pc (about USD 11~18)

Reference prices only; final price subject to quotation. (1 USD ≈ 7.2 CNY)

5. Applications

  • Data-center distribution type-2 protection.
  • UPS inlet surge protection.
  • Telecom power cabinets at cell sites.
  • Outdoor CCTV distribution boxes.
  • Factory motor control cabinets.
  • Medical equipment upstream protection.
  • PV AC combiner boxes.

6. Installation & Maintenance

Installation

  • Clip the SPD base onto the DIN rail in the board.
  • Feed L/N/PE busbar to the base top terminals.
  • Base bottom feeds downstream breaker and UPS.
  • PE ground wire short and thick (>=16 mm2 green-yellow).
  • Insert the SPD module until it clicks.
  • Wire the remote contact to DCIM.
  • Confirm the window is green.
  • Energize; measure downstream voltage.

Maintenance

  • Check the window quarterly (green = OK).
  • Inspect after storm seasons.
  • Red window means degraded module — swap on power-off.
  • On remote alarm, first read the window.
  • Measure ground resistance yearly (<=4 ohm).
  • Series an SCB before the SPD (prevents cabinet fire on SPD short).
  • Do not coil the ground wire (inductance spoils clamping).
  • Replace modules every 5 years or after a major strike.

7. FAQ

  • Q:Type-1 or type-2?
    A:By location. Main incomer (after transformer) uses type-1 (>=80kA); floor/room boards use type-2 (40kA); equipment outlets use type-3 (10kA). The three stages coordinate; energy is dissipated step by step. Type-1 alone leaves residual voltage that kills sensitive gear.
  • Q:Window turned red, can I keep using it?
    A:No. Red means the varistor has degraded to a short; leaving it in burns the busbar. Power off, pull the module, and swap. The base stays; the swap takes seconds.
  • Q:How thick should the ground wire be?
    A:For a type-2 SPD use >=16 mm2 stranded green-yellow copper, as short as possible (<=0.5 m), straight to the rack ground bar. Longer wires add inductance that raises residual voltage and defeats the SPD. No bends.
  • Q:Does the SPD affect power supply?
    A:No. The SPD is paralleled across the bus; at normal voltage it is high-impedance and draws no current. It conducts only during overvoltage clamps, then returns to high-impedance. It consumes no power in normal service.

8. Industry Trends & Selection

AC SPDs are moving from single type to T1+T2 combo units handling both 8/20us and 10/350us waveforms. Smart SPDs add remote contacts and surge counters on web pages. Plug-in modular is mainstream for hot swap. PV and storage are driving DC SPD demand. Select by location (type-1 80kA / type-2 40kA / type-3 10kA), by supply (1P+N or 3P+N), and by monitoring need. Room boards prefer type-2 40kA with remote contact tied to DCIM.

9. Delivery & Service

KITOZER sizes KTR-SPD-AC units by board location and supply type, and provides wiring diagrams and grounding advice. Delivery includes SPD module, base, remote lead, manual and certificate. Degraded modules are replaced free under warranty.

10. Notes

A common pitfall is a long, coiled ground wire. During a surge, even a small loop adds inductance that raises residual voltage and nullifies the SPD. The ground wire must be short, straight and thick, running straight from the SPD to the ground bar — no branching through other terminals.

Another pitfall is skipping the backup protector (SCB). A failed SPD is a short that can blow the busbar and burn the cabinet. Series a dedicated SCB (or C-curve MCB) ahead of the SPD so an SPD short trips and isolates without affecting other circuits.

Selection summary: type-2 40kA; modular; remote alarm; short thick ground; add SCB. The power SPD is the cabinet’s lightning arrestor; keys are staged coordination, short ground paths, and timely module swaps.

Tip: on first energization, if the downstream breaker will not close, pull the SPD module and retry. Some units arrive with a damaged varistor from shipping and short on first power. If it closes without the module, the SPD is bad — swap it.