KITOZER
KITOZER

KITOZER Outdoor Intelligent Integrated Cabinet Installation & Protection Guide

KITOZER Outdoor Intelligent Integrated Cabinet Installation & Protection Guide

Model: KTR-OC Series | IP55 (IP65 optional) | Operating temperature -40 °C to +55 °C

Product Overview

The KITOZER KTR-OC outdoor intelligent integrated cabinet is a purpose-built enclosure for 5G base stations, power distribution automation, traffic monitoring, surveillance, edge computing and outdoor energy storage. Factory prefabricated and modular, it only needs a concrete foundation, cabinet placement and simple wiring on site, cutting build time by over 80% and total cost by over 50% compared with a traditional equipment room.

The cabinet uses an isolated dual-cabin design: equipment cabin and battery cabin are temperature-controlled and wired independently, so battery heat and IT heat do not interfere. The shell is 2.0 mm cold-rolled steel with hot-dip zinc undercoat plus outdoor polyester powder topcoat, rated for 1000 h salt spray. Coastal and chemical-plant sites can be upgraded to IP65 and C4/C5 corrosion protection.

Protection & Environmental Adaptation

Threat Design response
Rain / dust IP55 standard, IP65 optional; EPDM foam gasket, raised base, bottom-entry cable glands
Heat / cold -40 to +55 °C operation; PTC heating below -10 °C; VFD AC for high-temperature cooling
Salt spray / corrosion ≥80 µm zinc + ≥60 µm polyester powder; 1000 h salt spray; C4/C5 optional
Typhoon / seismic Withstands 35 m/s (Grade 12) wind; seismic grade 8; channel-steel base ≥1500 kg
Lightning C+D surge protection, 40 kA on power, 5 kA on signal; grounding ≤4 Ω
Theft / vandalism Three-point anti-theft lock (GA/T 73 grade B); door + vibration + PIR alarms

Hybrid Thermal Management

KTR-OC combines VFD air conditioner, air-to-air heat exchanger, smart fan and PTC heater, automatically switching based on internal load and ambient temperature. Total-cabinet PUE ≤1.2.

  • VFD AC: 2000 / 3000 / 5000 W cooling, APF ≥3.2, equipment cabin ±0.5 °C;
  • Heat exchanger: all-aluminum counter-flow, ≥65% efficiency, 500/1000/1500 W;
  • Smart fans: 4× PWM axial fans with G4 filter, emergency mode on AC failure;
  • PTC heater: 200/500/1000 W, starts at 5 °C, 85 °C thermal cutout, open-flame free.

FSU Monitoring

An embedded FSU (ARM Cortex-A7 quad-core) offers 8× AI, 16× DI, 8× DO, 2× GbE and built-in 4G (5G/LoRa/NB-IoT optional). It speaks Modbus RTU/TCP, MQTT, HTTP, SNMP and IEC 104. It samples T/H (±0.3 °C / ±2% RH), water leak (0.5 mm trigger), smoke, V/A (0.5 class), door and vibration across 200+ points, with ≥30 days local storage.

Specifications

Item Value
Standard sizes 1200 W × 800 D × 2000 H / 900 W × 900 D × 2100 H mm (multiple tiers)
Max custom size 2500 W × 1200 D × 2500 H mm
Configuration Dual cabin (equipment + battery) / triple cabin
Sheet thickness Frame 2.0 mm, door 1.5 mm, base 3.0 mm channel steel
Ingress protection IP55 (IP65 optional)
Operating temperature -40 °C to +55 °C
Wind resistance Grade 12 typhoon (35 m/s)
Seismic Grade 8 (GB 50260-2013)
Input AC 220 V±20% / optional DC -48 V / AC 380 V three-phase
Output circuits 8× 10 A + 4× 16 A standard, expandable to 24
Cooling AC + heat exchanger + fan + PTC hybrid
Whole-cabinet PUE ≤1.2
Fire Combined smoke+heat detector, optional S-type aerosol suppression
Remote comms 4G global / Ethernet, 5G optional

Reference Configuration & Price

Model Typical scope Reference price (incl. tax & freight)
KTR-OC-S1-F15 Single cabin / 1.5 kW fan cooling / basic distribution / FSU ¥18,000 – ¥25,000
KTR-OC-S2-H20 Dual cabin / 2.0 kW heat-exchanger / battery bay / 4G FSU ¥32,000 – ¥45,000
KTR-OC-S2-A30 Dual cabin / 3.0 kW VFD AC / battery bay / access + CCTV ¥48,000 – ¥65,000
KTR-OC-S3-A50 Triple cabin / 5.0 kW AC / aerosol fire / C4 anti-corrosion ¥75,000 – ¥100,000

In USD, roughly US$2,500 – US$13,900. Based on exchange rate as of October 2026 (1 USD ≈ 7.2 CNY). Prices are for reference only; actual quotation may vary by cooling method, battery configuration, surge-protection level, corrosion class and optional CCTV/fire options.

Installation & Site Notes

Site selection: Choose elevated, well-drained ground; top of foundation must be ≥300 mm above historical flood level. Soil bearing ≥100 kPa. Keep ≥800 mm front clearance for door opening and ≥500 mm side clearance.

Foundation: C20 concrete, 200–300 mm high, embedded 4-M16 anchor bolts and grounding flat steel. Cure ≥7 days before placing the cabinet.

Placement: Use a pallet truck or lifting strap — never drag. Level the cabinet to ≤1.5‰ verticality, then lock with washers and double nuts.

Wiring: All cables enter through bottom glands; strong and weak wires run in separate conduits. Bond the grounding busbar to site earth with ≥16 mm² copper, ≤4 Ω.

Commissioning: Test insulation (≥10 MΩ), grounding, AC on/off, heat-exchanger set-point, FSU uplink, smoke/aerosol linkage and remote door-unlock in sequence.

Maintenance Cycle

Monthly: inspect door gaskets, locks and fan filters. Quarterly: measure grounding resistance, clean the AC condenser, check battery terminal voltage. Annual: inspect the anti-corrosion coating, lubricate locks and hinges, calibrate FSU sensors, and weigh the aerosol suppression unit to confirm shelf life. The FSU continuously monitors 200+ points and pushes alarms to local sounder, SMS, platform pop-up and WeChat-style push within 5 seconds; over 90% of routine operations (parameter change, firmware upgrade, remote reboot, thermal mode switch) can be done without a site visit.

KTR-OC cabinets are certified to YD/T 1537, YD/T 5186 and IEC 61969-1, with C4/C5 anti-corrosion variants for coastal and chemical-plant sites. Optional extras include H.265+ CCTV, an aerosol suppression unit, 5G module, photovoltaic input and a pole/wall-mounting kit.


[Render location: KTR-OC dual-cabin exterior / equipment cabin interior / FSU UI / concrete foundation install]

Keywords: outdoor integrated cabinet, IP55 outdoor cabinet, IP65 base station cabinet, telecom outdoor enclosure, edge computing outdoor cabinet, dual-cabin battery cabinet, KITOZER KTR-OC

Meta Title: KITOZER Outdoor Intelligent Integrated Cabinet Installation & Protection Guide

Meta Description: KITOZER KTR-OC outdoor integrated cabinet: -40 to +55 °C, IP55/IP65, dual-cabin, hybrid cooling, built-in FSU. Specs, tiers and installation notes.

Meta Keywords: outdoor cabinet, IP55, IP65, base station enclosure, edge computing cabinet, KITOZER

Contact: Guangzhou Lai’an Intelligent System Development Co., Ltd. | Tel/WhatsApp: +86 18520668845 | Web: gdlain.com | Address: Zhongrun Industrial Park, Shilou, Panyu, Guangzhou, China

Shopping Cart