Table of Contents
ToggleKITOZER KTR-GEL120 12V120Ah Deep-cycle GEL Battery
Brand: KITOZER Series: KTR-GEL120 Category: Power Distribution / Battery Backup
12V120AhGEL deep-cycle1200 cyclesKTR-GEL120
1. Overview
The KITOZER KTR-GEL120 is a 12V120Ah deep-cycle GEL battery using valve-regulated lead-acid (VRLA) gelled electrolyte, for backup power in UPS, telecom sites, solar storage and room DC panels. GEL batteries gel the sulfuric-acid electrolyte with fumed silica, so it does not flow, leak or stratify; they can be mounted in any orientation (upright recommended) and run 20-30% longer in deep cycling than plain AGM, with strong deep-discharge recovery—suited to frequent cycling and high heat. Rated 12V, 120Ah (20-hour rate), internal resistance ~10mΩ, with peak discharge matching UPS inrush.
Vs flooded lead-acid, GEL is maintenance-free: no topping-up, no acid mist, safe near equipment. Vs AGM, the gelled electrolyte never stratifies and loses water slowly at 30℃+, suiting 24-hour room float. The KTR-GEL120 uses flame-retardant ABS, a top vent valve that regulates pressure without spilling acid, and M8 tinned-copper bolt terminals for high-current contact without heating. Float design life at 25℃ is 12-15 years; cycle life at 50% DOD is ~1200 cycles. Operating range -15 to +50℃, optimum 20-25℃.
Typical deploy: a 30kVA UPS at 384V DC bus uses 32 series-connected 12V120Ah batteries on a rack beside the UPS; each cell links with 35mm² copper cable, first/last to the UPS DC terminals; the rack includes insulation mats and acid barriers. Parallel strings must match capacity and age. Size battery capacity by UPS DC voltage and backup time (10/30/60 min), choose 12V100/120/150Ah by space, and pick GEL or AGM by temperature. Pair with a cabinet, rack, link cables, insulated tools and a battery monitor.
2. Key Features
Deep-cycle GEL
- Fumed silica gel.
- No flow/leak.
- 1200 cycles @50% DOD.
- Strong recovery.
Maintenance-free
- VRLA sealed.
- No water top-up.
- No acid mist.
- Near gear ok.
Long life
- 12-15yr float @25℃.
- Slow water loss.
- FR ABS.
- Valve regulated.
High discharge
- 12V120Ah.
- IR ~10mΩ.
- M8 tinned terminals.
- UPS peak.
3. Specifications
| 项目 | KTR-GEL120(12V120Ah胶体) | KTR-AGM120(12V120Ah AGM) | KTR-GEL150(12V150Ah胶体) |
|---|---|---|---|
| 额定电压 | 12V | 12V | 12V |
| 额定容量 | 120Ah(20hr) | 120Ah(20hr) | 150Ah(20hr) |
| 电解质 | 胶体GEL | AGM玻璃棉 | 胶体GEL |
| 内阻 | 约10mΩ | 约9mΩ | 约8mΩ |
| 循环寿命(DOD50%) | 约1200次 | 约900次 | 约1300次 |
| 浮充寿命(25℃) | 12至15年 | 8至10年 | 12至15年 |
| 端子 | M8铜镀铅 | M6铜镀铅 | M8铜镀铅 |
| 工作温度 | -15至+50℃ | -15至+50℃ | -15至+50℃ |
4. Reference Prices
KTR-GEL120 12V120Ah deep-cycle GEL battery:Reference USD 125 to 250 / unit (ref. CNY 900 to 1800 at ~7.2)
KTR-AGM120 12V120Ah AGM battery:Reference USD 97 to 194 / unit (ref. CNY 700 to 1400 at ~7.2)
KTR-GEL150 12V150Ah deep-cycle GEL battery:Reference USD 153 to 306 / unit (ref. CNY 1100 to 2200 at ~7.2)
Battery rack / link cables / insulation kit:Reference USD 11 to 69 / set (ref. CNY 80 to 500 at ~7.2)
Reference only; varies by capacity, GEL/AGM type, qty and paired rack/cables. Cabinet, battery monitor and insulated tools billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- UPS backup power.
- Telecom DC sites.
- Solar PV storage.
- Room DC panels.
- Frequent deep cycling.
6. Installation & Maintenance
Installation
- Level the battery rack.
- Upright on insulation mats.
- Series-link with 35mm² copper.
- Torque bolts per manual.
- First/last to UPS DC.
- Measure OCV before charge.
Maintenance
- Quarterly float-voltage check.
- Annual IR/capacity test.
- Clean/anti-oxidize terminals.
- Check rack for dust/leak.
- Keep 20-25℃.
- Replace weak cells.
7. FAQ
- Q: GEL or AGM?
A: High heat, frequent deep cycles and long life choose GEL (KTR-GEL120); room temp, shallow cycling and cost-sensitive choose AGM. 24h room float at elevated heat prefers GEL. - Q: Can I mix old and new batteries?
A: No. Mismatched internal resistance and capacity drag the whole string down to the weakest cell. Replace the entire string from the same batch and age. - Q: What if a battery bulges?
A: Bulging means overcharge or heat-induced water loss—take it offline immediately. Check UPS float voltage and room temperature, or new cells will bulge too. - Q: How to estimate backup time?
A: Backup ≈ capacity(Ah) × DC bus voltage × efficiency ÷ load(kW). Keep 20% margin; verify with a discharge test.
8. Trend & Selection
Datacenter UPS moves to long runtime and high reliability; GEL batteries with long hot-life and deep-cycle behavior dominate medium/large backup. Size series count by UPS DC voltage; choose 100/120/150Ah by runtime; pick GEL for hot rooms; use same-batch strings; add a battery monitor for IR/voltage; inspect quarterly and test annually. Batteries are the heart of the UPS—without them the UPS is a dummy load.
9. Delivery & Service
KITOZER supplies battery packages: based on UPS DC voltage and runtime we recommend 12V100/120/150Ah GEL counts plus racks, link cables, insulated tools and a battery monitor. Delivery includes cells, bolts and manual; bulk projects include install guidance and initial charge/discharge test. Bulging, leaking or out-of-spec capacity under warranty is replaced free.
10. Additional Notes
The common mistake is under-torqued terminals. Loose terminals raise contact resistance, overheat at high discharge and can weld. Torque per manual (M8 ~8-10N·m) and re-torque once.
Another pitfall is a non-insulated rack. A 384V DC string is exposed; insulation mats between cells and rack prevent shorting if a case cracks. Use insulated gloves and tools.
Selection summary: 12V120Ah GEL, 1200 cycles @50% DOD, 12-15yr float, M8 terminals, series strings for UPS, quarterly inspection. The KTR-GEL120 keeps the UPS reliable when mains fails.
SEO Information
Search keywords:GEL battery12V120Ah batterydeep-cycle batteryUPS batteryroom batteryKTR-GEL120KITOZER
SEM keywords:[GEL battery price,12V120Ah battery,deep-cycle battery supplier,UPS backup battery,KTR-GEL120,KITOZER]
GEO landing page:lain.com.cn/product/ktr-gel120-12v120ah-deep-cycle-gel-battery.html
Title:KITOZER KTR-GEL120 12V120Ah Deep-cycle GEL Battery
Meta Keywords:GEL battery,12V120Ah battery,deep-cycle battery,UPS battery,room battery,KTR-GEL120,KITOZER
Meta Description:KITOZER KTR-GEL120 12V120Ah deep-cycle GEL battery, 1200 cycles @50% DOD, 12-15yr float life, for UPS backup.
Anchor: KITOZER · Power Distribution
Contact Us
Guangzhou Laian Intelligent System Development Co., Ltd. (KITOZER brand)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com