KITOZER 12V 150Ah gel battery

KITOZER KTR-GEL150 12V150Ah Deep-Cycle Gel Battery

Brand: KITOZER Series: KTR-GEL150 Category: Power Distribution / Battery

12V150AhDeep-cycle gel12yr floatSealed VRLA

1. Overview

[‘The KITOZER KTR-GEL150 is a 12 V 150 Ah deep-cycle valve-regulated lead-acid (VRLA) battery using gel electrolyte, with a 12-year float design life (25°C), for UPS, DC panels and telecom backup. The 12 V block packages six 2 V cells in a flame-retardant ABS case; a single block gives 12 V, and blocks series into 24/48/192/240 V strings or parallel for more capacity. Deep-cycle means it survives thousands of cycles at 50% depth of discharge (DOD), suiting frequent outages, long backup and solar storage.’, ‘The KTR-GEL150 uses flat plates with gel electrolyte and AGM glass-mat separators. vs flooded cells, VRLA is sealed, leak-free, no watering, and mounts in any orientation except inverted; vs AGM starved-electrolyte, the gel electrolyte stays gelatinous with no stratification, longer deep-cycle life and lower self-discharge (~2%/yr). The flame-retardant ABS case has a top safety valve (10-30 kPa) that vents on overcharge and seals in normal service. M8 tinned-copper terminals give low resistance for high discharge. Size about 483×170×240 mm, weight ~45 kg. vs 2 V cells, the 12 V block installs simply with few cables, suiting small-to-mid UPS; vs 100 Ah it lasts longer on backup.’, ‘Typical deploy: a 60 kVA UPS with 192 V DC bus uses 16 KTR-GEL150 in series. The rack has two layers of eight, with M8 copper bus bars between blocks. After UPS startup set float 13.5-13.8 V/block (25°C), equalize 14.4-14.7 V. Keep the battery room at 20-25°C; every 10°C rise roughly halves float life. Full-load backup ~30 min (150 Ah×192 V÷60 kVA≈0.48 h after inverter efficiency). Select series count by UPS DC voltage, capacity by backup time, and 12 V block vs 2 V cells by space.’]

2. Key Features

Deep-cycle gel

  • Gel electrolyte.
  • 1000+ cycles @50% DOD.
  • No stratification.
  • ~2%/yr self-discharge.

12 V block

  • Six 2 V cells.
  • Flame-retardant ABS.
  • 12 V per block.
  • Series/parallel expand.

Long float life

  • 12 yr design (25°C).
  • Sealed VRLA.
  • Safety vent.
  • Maintenance-free.

High-current terminals

  • M8 tinned copper.
  • Low resistance.
  • UPS discharge ready.
  • 483×170×240 mm.

3. Specifications

Item KTR-GEL100 (12V100Ah) KTR-GEL150 (12V150Ah) KTR-GEL200 (12V200Ah)
Nominal voltage 12 V 12 V 12 V
Nominal capacity 100 Ah 150 Ah 200 Ah
Float design life 12 yr 12 yr 12 yr
Float voltage 13.5-13.8 V 13.5-13.8 V 13.5-13.8 V
Equalize voltage 14.4-14.7 V 14.4-14.7 V 14.4-14.7 V
Weight ~30 kg ~45 kg ~63 kg
Terminal M8 copper M8 copper M8 copper

4. Reference Prices

KTR-GEL150 12V150Ah gel battery: Reference USD 136 to 219 / unit (ref. CNY 980 to 1580 at ~7.2)

KTR-GEL100 12V100Ah gel battery: Reference USD 95 to 150 / unit (ref. CNY 680 to 1080 at ~7.2)

KTR-GEL200 12V200Ah gel battery: Reference USD 192 to 303 / unit (ref. CNY 1380 to 2180 at ~7.2)

Battery rack / busbar / breaker kit: Reference USD 14 to 69 / set (ref. CNY 100 to 500 at ~7.2)

Reference only; varies by config, quantity and scope. Install accessories billed separately. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS backup.
  • DC panel control power.
  • Telecom backup.
  • Solar storage.
  • Long backup scenarios.

6. Installation & Maintenance

Installation

  • Level the rack.
  • Wire string per count.
  • Torque M8 busbars.
  • Check polarity.
  • Set float voltage.
  • Measure string voltage.

Maintenance

  • Measure cell voltage quarterly.
  • Keep room 20-25°C.
  • Tighten terminals.
  • Check for swelling.
  • Annual capacity test.
  • Recycle retired cells.

7. FAQ

  • Q: Gel or AGM?
    A: Choose gel for deep cycling, frequent discharges and solar; AGM suffices for pure float backup. Gel tolerates deep discharge better but costs a bit more.
  • Q: 12 V block or 2 V cells?
    A: Small-to-mid UPS (≤100 kVA) use 12 V blocks for simple install; large/long-backup systems use 2 V cells for flexible parallel and single-cell replacement.
  • Q: How to size backup time?
    A: Time ≈ total energy (Ah×V) ÷ load power, × inverter efficiency (~0.9). 150 Ah×192 V÷60 kVA≈0.48 h.
  • Q: How long do they last?
    A: 12-year float design at 25°C; every 10°C rise roughly halves life. Battery-room temperature control is the key.

8. Trend & Selection

UPS backup moves from flooded cells to VRLA gel/AGM, with long life and maintenance-free as the trend. Set series count by UPS voltage, capacity by backup time, and choose gel for deep cycling. Battery-room temperature control and periodic capacity tests extend string life; retired cells recycle as hazardous waste.

9. Delivery & Service

KITOZER supplies battery packages: based on UPS power and backup time, we recommend capacity and series count plus racks, busbars, fuses and breakers. Bulk projects include factory capacity-test reports. Cells below 80% rated capacity under warranty are replaced free.

10. Additional Notes

The common mistake is poor battery-room temperature control. Above 30°C, life decays fast; run AC to hold ~25°C in summer—the highest-ROI life-extension step.

Another pitfall is under-torqued busbars. Loose M8 joints heat and arc under high discharge; torque to spec (~12 N·m) and mark the joint.

Selection summary: 12 V150 Ah; deep-cycle gel; 12-yr float; M8 copper terminals; maintenance-free VRLA. The KTR-GEL150 suits small-to-mid UPS and DC panels and tolerates frequent outages. Hold the room at 20-25°C, measure cell voltage quarterly, and recycle retired cells as hazardous waste.

Before commissioning, run a full capacity test to confirm at least 95% of rated capacity. A single cell reading low in service is usually a laggard—recharge or replace it before it drags the whole string. Leave airflow gaps between layers and insulate connectors to prevent short circuits.

SEO Information

Search keywords:12V150Ah batterydeep cycle gel batteryUPS backup batteryVRLA gel cellroom batteryKTR-GEL150KITOZER

SEM keywords:[12V150Ah battery,deep cycle gel battery,UPS backup battery,VRLA gel cell,room battery,KTR-GEL150,KITOZER]

GEO landing page:lain.com.cn/product/ktr-gel150-12v150ah-deep-cycle-gel-battery.html

Title:KITOZER KTR-GEL150 12V150Ah Deep-Cycle Gel Battery

Meta Keywords:12V150Ah battery,deep cycle gel battery,UPS backup battery,VRLA gel cell,room battery,KTR-GEL150,KITOZER

Meta Description:KITOZER KTR-GEL150 12V150Ah deep-cycle gel VRLA battery, 12-year float life, for UPS and DC panel backup power.