KITOZER KTR-BAT7D2 Battery / 12V7Ah Deep Cycle

KITOZER KTR-BAT7D2 Battery / 12V7Ah Deep Cycle

Brand: KITOZER Series: KTR-BAT7D2 Category: Power Distribution / Battery Backup

12V7AhDeep cycleVRLA lead-acidFlame-retardant caseMaintenance-free

[Product image: ktr-bat7d2-12v7ah-deep-cycle-battery.jpg]

1. Overview

On mains failure, a UPS inverts from its battery stack, and runtime depends on battery capacity and health. Small UPS, access control, environmental hosts and emergency lighting commonly use a small sealed 12V7Ah lead-acid battery. Deep-cycle design means the battery recovers after moderate discharge, suiting repeated charge-discharge backup better than a starter battery. Small as it is, the battery is the real carrier of UPS runtime; one weak cell drags down the whole string.

The KITOZER KTR-BAT7D2 is a 12V7Ah deep-cycle VRLA valve-regulated lead-acid battery. Rated 12V and 7Ah (20-hour rate), it uses an AGM absorbed-glass-mat separator so electrolyte is immobilized and the case can be mounted upright. The flame-retardant ABS case meets UL94-V0, with T2 copper terminals. Design float life is about 3-5 years at 25 C, low self-discharge, and it can be recharged after long storage. Cells series up to 24/36/48V for small UPS, access controllers and emergency lights.

Selection confirms system voltage (number in series), total capacity for desired runtime, space and weight, and terminal type. A single 12V7Ah backs small loads briefly; UPS runtime is calculated from capacity times cell count. New batteries should be topped up before install; when replacing a string, use same-batch cells together rather than mixing old and new. Keep the battery room at 20-25 C; every 10 C rise roughly halves float life.

2. Key Features

12V7Ah deep cycle

  • 12V, 7Ah (20-hour rate).
  • Deep-cycle, tolerant of cycling.
  • AGM absorbed separator.
  • VRLA valve-regulated sealed.

Safety and build

  • UL94-V0 flame-retardant case.
  • T2 copper terminals.
  • No leakage, upright mount.
  • Low self-discharge.

Backup use

  • Small UPS backup.
  • Access / alarm hosts.
  • Emergency lighting.
  • Series to stack voltage.

3. Specifications

Item Specification
Nominal voltage 12 V
Nominal capacity 7 Ah (20-hour rate)
Battery type VRLA AGM lead-acid
Design life 3-5 years (25 C float)
Terminals T2 copper
Case ABS, UL94-V0
Self-discharge <= 3% / month (25 C)
Charge voltage Float 13.5-13.8 V
Operating temp -15 to +50 C
Size about 151 x 65 x 94 mm

4. Reference Prices

KTR-BAT7D2 12V7Ah deep-cycle battery: USD 13~22 (ref. CNY 90~160)

Interconnect cable (series): USD 1.5~3.5 (ref. CNY 10~25)

Battery shelf / tray: USD 4~8 (ref. CNY 30~60)

Reference only; final quote applies. 1-year warranty. Bulk pricing available. Certificate and manual included. Exchange: 1 USD ≈ 7.2 CNY.

5. Applications

  • Small UPS backup.
  • Access control and alarm panels.
  • Environmental monitoring hosts.
  • Emergency lighting and fire backup.
  • Small DC panels and instruments.

6. Installation & Maintenance

Installation

  • Top up charge before install.
  • Replace a string in same batch.
  • Mount upright, terminals aligned.
  • Torque series interconnects.
  • Secure on a shelf against tipping.
  • Ventilated, away from heat.
  • Connect to the UPS charger.

Maintenance

  • Measure terminal voltage and resistance quarterly.
  • Clean terminals against corrosion.
  • Check interconnect torque.
  • Log battery-room temperature.
  • Replace weak cells as a string.

7. FAQ

  • Q: How long will 7Ah last?
    A: It depends on load. A small UPS backs a few devices for minutes to a dozen; calculate runtime from load power and capacity.
  • Q: Can I mix old and new?
    A: Not recommended. Different internal resistance causes uneven charging and accelerated weak cells; replace the whole string in batch.
  • Q: What if a battery swells?
    A: Swelling means overcharge or internal degradation. Stop and replace immediately, and check charger voltage to avoid leakage.
  • Q: Do I need to add water?
    A: No. VRLA is sealed and maintenance-free; routine checks are voltage and appearance only.

8. Trend & Selection

Backup power moves from pure lead-acid toward lithium, hybrid supply and battery monitoring (BMS), while small VRLA still dominates UPS and access. Batteries trend toward lower self-discharge, longer float life and built-in voltage sense terminals. Size by system voltage and runtime, favoring string consistency and room temperature control.

9. Delivery & Service

KITOZER ships KTR-BAT7D2 with the battery, T2 interconnect tabs, certificate and manual. Series cables and trays are supplied to order, with a runtime estimate table.

10. Notes

A common mistake is replacing only the weak cell. A new cell in an old string mismatches resistance and soon creates a new weak cell; replace the whole string.

Another pitfall is an uncontrolled battery room. Heat sharply shortens float life; hold 20-25 C with ventilation.

In short: 12V7Ah, deep-cycle, VRLA maintenance-free, UL94-V0, series-capable. It is a common backup for small UPS and emergency power.

System-wise, string runtime is set by the weakest cell, so string consistency and periodic internal-resistance tests matter more than single-cell capacity.

Cost-wise, a cell costs about a hundred CNY, but downtime from insufficient backup on a power cut costs far more.