KITOZER KTR-PSM9 Three-Phase Class-C 40KA Surge Protective Device

KITOZER KTR-PSM9 Three-Phase Class-C 40KA Surge Protective Device

Brand: KITOZER Series: KTR-PSM9 Category: Power Distribution / Surge Protection

Three-phase SPDClass C 40KADIN railRemote contactFailure indicatorSurge protection

[Product image: ktr-psm9-three-phase-40ka-spd.jpg]

1. Overview

Lightning and grid switching surges are hidden killers of data center gear. During a strike, surges invade through power and signal lines; thousands of volts of spikes punch through power modules and mainboards, batch-destroying UPS and servers. A surge protective device (SPD) is a parallel “discharge path” across the power line — high impedance at normal times, but it conducts instantly during a surge, clamping peak voltage to what equipment can take and dumping current to ground. Data center protection is staged: main switchgear uses Class B (100KA+), floor/hall cabinets use Class C (40KA), and device front ends use Class D (10KA), each stage coordinating to clamp step by step.

KITOZER KTR-PSM9 is a three-phase Class-C 40KA power SPD. Plug-in modular structure, 35 mm DIN rail, installed on the incoming side of the hall cabinet (row PDU). One module per pole (three phases + N + PE), max discharge current 40KA (8/20 μs), nominal 20KA, voltage protection level ≤1.8 kV. Each module has a failure indicator window (green OK / red failed) and a remote-signaling auxiliary contact (dry contact to the DCIM platform for auto-alarm on SPD failure). A backup protection breaker (32~63A) must be series-wired upstream to prevent SPD short-circuit fire. Operating voltage 385 VAC (three-phase).

Selection points: protection class (B/C/D coordination; hall distribution generally Class C), max discharge current (40 KA is typical Class C; lightning-prone areas choose 60KA), pole count (three-phase five-wire uses 4P+N), remote-signaling need (must have contacts if tied to DCIM), backup protection (upstream breaker rating), and mounting (DIN rail vs screw). Note SPDs have a service life — every surge discharge ages the module; when the window turns red it must be replaced, otherwise it is as if none is installed.

2. Key Features

Three-phase Class C 40KA

  • Max discharge 40KA.
  • Nominal 20KA.
  • Clamp ≤1.8 kV.
  • 385 VAC operation.

Modular plug-in

  • 35 mm DIN rail.
  • Modules replaceable individually.
  • Hot-swap (with caution).
  • Easy maintenance.

Remote failure signal

  • Green/red window.
  • Dry contact remote.
  • Ties to DCIM.
  • Auto-alarm on failure.

Backup protection

  • Upstream series breaker.
  • Prevents SPD short.
  • Fire safety.
  • 32~63 A rating.

3. Specifications

Item KTR-PSM9
Model KTR-PSM9
Protection class Class C (secondary)
Max discharge (8/20μs) 40KA/pole
Nominal discharge 20KA/pole
Voltage protection level ≤1.8 kV
Max continuous voltage 385 VAC
Poles 4P+N (3P5W)
Mounting 35 mm DIN rail
Failure indicator Green/red window
Remote contact Dry (5A/250VAC)
Backup protection Upstream breaker 32~63 A
Response time ≤25 ns

4. Reference Prices

KTR-PSM9 three-phase Class C 40KA SPD (4P+N, DIN rail, remote signal): Reference USD 49~90 / set (ref. CNY 350~650 at ~7.2)

KTR-PSM9B 60KA reinforced version (with backup breaker): Reference USD 76~132 / set (ref. CNY 550~950 at ~7.2)

Reference only; tiered by poles and current. Grounding busbar work not included. Volume discount above 5 sets. Class D final SPD available in same series. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Row cabinet / power cabinet secondary protection.
  • UPS incoming surge protection.
  • AC and power equipment distribution front end.
  • Outdoor feeder box protection.
  • Lightning-prone area power systems.

6. Installation & Maintenance

Installation

  • With power off, clip SPD onto 35 mm rail.
  • Upstream to phases (L1/L2/L3) and N; downstream to PE bus.
  • Series-wire upstream backup breaker (32~63 A).
  • Wire remote contact to DCIM module.
  • Before energizing, verify tight wiring and green window.

Maintenance

  • Monthly visual window check (replace when red).
  • Inspect modules after thunderstorms.
  • Measure ground resistance yearly (≤4 Ω).
  • Tighten terminals periodically (thermal cycling loosens).
  • Test remote-signal function annually.

7. FAQ

  • Q: Can I keep using a red-window SPD?
    A: No. The module has degraded/shortened; replace immediately — otherwise fire risk.
  • Q: How to coordinate Class C and D?
    A: Main cabinet Class B → row cabinet Class C (KTR-PSM9) → PDU front Class D; keep 10 m between stages or add decoupling inductor.
  • Q: What does the remote contact connect to?
    A: A DCIM dry-contact input module; SPD failure triggers a platform alarm.
  • Q: What if no backup breaker?
    A: An SPD short without upstream protection can ignite — always series a breaker or fuse.

8. Trend & Selection

Protection evolves from “single SPD” to “staged coordination + condition monitoring.” Trends: SPDs with remote signaling and discharge counters (predict lifespan), smart SPDs (Modbus read module status), plug-in modules (hot-swap without outage), and linkage with online ground-resistance monitoring. Selection: hall distribution uses Class C 40KA; lightning-prone areas choose 60KA; three-phase five-wire 4P+N; remote signaling to DCIM is mandatory; upstream backup breaker cannot be skipped; replace on red window; measure ground yearly. SPDs are consumables — install is not the end; an aged un-replaced unit is a paid-for hazard.

9. Delivery & Service

KITOZER provides SPD selection: by distribution stage, lightning risk, and DCIM monitoring needs, we configure SPD class, poles, and remote-signal scheme. Bundled with power cabinets, grounding busbars, and DCIM modules. Delivery includes SPD body, modules, remote-contact wiring, and manual. Warranty covers wiring guidance and remote-signal commissioning.

10. Additional Notes

The most common fault: “SPD installed but remote signal not wired.” Operators don’t know the SPD has aged until a surge destroys equipment and they finally see the red window. The remote contact must go to DCIM for auto-alarm — otherwise the SPD is a blind insurance policy, discovered only after the damage.

Another pitfall: “overlong SPD ground lead.” Surge discharge needs the shortest path; a lead over 0.5 m adds inductance that raises clamp voltage and degrades protection. Mount SPD near the PE bus with a short, thick copper wire.

Selection summary: Class C 40KA 3P5W; remote signal to DCIM; upstream backup breaker; short ground to PE; replace on red; yearly ground test. SPDs are high-leverage protection — a few-hundred-yuan device saves hundreds-of-thousands in equipment, but only if it’s healthy, wired right, and can alarm.