ToggleKITOZER KTR-CSP1 Coaxial Video Surge Protector
Brand: KITOZER Series: KTR-CSP1 Category: Power Distribution / Surge Protection
Coax SPDVideo surgeBNC75ΩSignal surgeIn-line
1. Overview
Many data-center cameras use coaxial (BNC) cable run in from outdoors — a camera on the roof or outer wall, coax through the wall into the hall to the recorder. That outdoor run is a “lightning conductor”: during a thunderstorm, surge rides the coax into the hall, damaging camera and recorder ports, or even traveling into the motherboard and killing the recorder. Power lines have power SPDs; signal lines need signal SPDs too — inserted at the hall entrance, they divert surge to the grounding bar and protect downstream gear. A coaxial video SPD does exactly this: BNC female-to-female, in series between camera and recorder, clamping surge to a safe voltage while passing video with low loss.
KITOZER KTR-CSP1 is a coaxial video signal surge protector: BNC female-to-female, 75Ω characteristic impedance (matched to coax video). Internally a multi-stage gas-discharge tube (GDT) + TVS: GDT diverts common-mode (line-to-ground) surge to earth, TVS clamps differential (line-to-line) spikes. Nominal discharge current 5 kA (8/20 μs), max 10 kA, residual voltage ≤90 V. Insertion loss ≤0.5 dB, no picture degradation. Bandwidth 0–2 GHz, compatible with analog CVBS and HD AHD/TVI/CVI. Metal housing, bottom ground lead (yellow-green to hall ground bar). In-line at the wall entry point.
Selection: connector type (BNC coax vs RJ45 network vs RS485 control — pick the right SPD for the line), impedance (video 75Ω, not 50Ω RF), discharge capacity (outdoor entry ≥5 kA), residual voltage (below downstream gear rating, ~1.5× max working voltage), insertion loss (video ≤0.5 dB), grounding (keep SPD ground lead short, ≤0.5 m). Notes: install at the line entry (outdoor wire hits SPD first); ground must be solid (≤4Ω); SPD is in-line — IN to outdoor, OUT to equipment; after a strike the SPD degrades — inspect regularly.
2. Key Features
Multi-stage
- GDT diverts common-mode.
- TVS clamps differential.
- 5 kA nominal.
- 10 kA max.
BNC 75Ω
- BNC F-F.
- 75Ω matched.
- ≤0.5 dB loss.
- 0–2 GHz.
Video-ready
- CVBS.
- AHD/TVI/CVI.
- No picture loss.
- In-line.
Ground diverts
- Yellow-green lead.
- To ground bar.
- Residual ≤90 V.
- Metal shield.
3. Specifications
| Item | KTR-CSP1 |
|---|---|
| Model | KTR-CSP1 |
| Connector | BNC F-F |
| Impedance | 75Ω |
| Nominal discharge | 5 kA (8/20μs) |
| Max discharge | 10 kA |
| Residual voltage | ≤90 V |
| Insertion loss | ≤0.5 dB |
| Bandwidth | 0–2 GHz |
| Signal | CVBS/AHD/TVI/CVI coax |
| Ground | Yellow-green lead |
| Mount | In-line at entry |
| Working temp. | -40~+85℃ |
4. Reference Prices
KTR-CSP1 single BNC coax video SPD: Reference USD 5~9 / unit (ref. CNY 35~65 at ~7.2)
KTR-CSP1-4 4-channel BNC coax SPD (DIN-rail): Reference USD 17~28 / unit (ref. CNY 120~200 at ~7.2)
Reference only. Excludes tax and freight; volume discount on request. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).
5. Applications
- Outdoor CCTV coax entry surge protection.
- Roof/outer-wall CCTV signal entry.
- Coax HD AHD/TVI systems.
- Broadcast video, RF coax.
- Elevator and perimeter camera entry.
6. Installation & Maintenance
Installation
- Mount at wall entry.
- IN to outdoor camera; OUT to recorder.
- Bottom yellow-green lead to ground bar.
- Keep lead ≤0.5 m.
- Bank multi-units in DIN-rail SPD box.
- Verify picture after power-up.
Maintenance
- Inspect after each storm season.
- Test discharge after a strike.
- Check ground lead tightness.
- Inspect BNC connectors.
- Watch degradation indicator.
7. FAQ
- Q: Do IP cameras (network cable) need SPD?
A: Yes — but an RJ45 network SPD, not BNC. PoE camera network cables need a network SPD at entry. KTR-CSP1 is for coax video only. - Q: Does SPD guarantee no lightning damage?
A: Not 100%. SPD clamps surge to a safe voltage to reduce damage; direct strikes or huge surges can still destroy. SPD works with good grounding and shielding as part of multi-stage protection. - Q: Does SPD hurt picture quality?
A: A qualified SPD adds ≤0.5 dB — invisible on analog and HD. Cheap impedance-mismatched SPDs cause ghosting; choose the 75Ω video-specific model. - Q: SPD lifespan?
A: Degrades a little each strike. Replace every 3–5 years, or when the indicator window turns red. Poor grounding accelerates wear.
8. Trend & Selection
Signal SPDs evolve from “single-stage GDT” toward “multi-stage + remote degradation monitoring.” Trends: integrated RJ45/BNC/RS485 in one DIN-rail module, SPD with remote-contact (degradation signal to DCIM), discharge capacity above 10 kA, low-capacitance designs for 4K/high-frequency, and SPD integrated with equipotential bars. Hall lightning protection relies on “equipotential bonding + multi-stage SPD”: power SPDs stage I/II/III, signal SPDs on signal lines, unified grounding. Selection: outdoor entry must have SPD, BNC 75Ω video-specific, ≥5 kA, short ground lead, in-line at entry. The signal SPD is the “lightning rod” for hall signal lines, keeping surges outside the door.
9. Delivery & Service
KITOZER provides signal-SPD selection: by signal type (coax video/network/RS485), connector, and entry count, we configure SPDs. Bundled with power SPDs, grounding bars, and surveillance systems. Delivery includes SPD, BNC connectors, ground lead, and manual. Warranty covers entry lightning design and grounding guidance.
10. Additional Notes
The most common fault: “ground lead too long.” The SPD is on the wall but the ground lead loops far to the bar; lead inductance slows diversion and the SPD is ineffective. Keep the lead short, ≤0.5 m, bonded locally to the equipotential bar.
Another pitfall: “IN/OUT reversed.” The SPD marks IN (outdoor) and OUT (equipment); reversing weakens protection. Many bidirectional SPDs work either way, but follow the labels.
Selection summary: BNC 75Ω, 5 kA, ≤0.5 dB loss, multi-stage GDT+TVS, in-line at entry, short ground lead. A few-dozen-yuan SPD protects thousands in recorders and cameras.