Operation Manual for Automated Testing of Fixture Robot Arm Remote Control

Operation Manual for Automated Testing of Fixture Robot Arm Remote Control

Version: V2.0

Release Date: May 17, 2026

Applicable Equipment: Dual-Station Fixture Robot Arm Remote Control Automated Testing System

Applicable Software: Ai Recognition Chat Enhanced Edition 25-6-26

Applicable Products: Mijia Smart Bathroom Heater P1 Motion-Sensing Remote Control and Various Light-Touch Household Appliance Remote Controls

Table of Contents

Preface

This manual is specifically written for the dual-station fixture robot arm remote control automated testing system. It is applicable to Windows 7/10 operating systems and is developed based on the Ai Recognition Chat Enhanced Edition (version 25-6-26) software. Throughout the entire process, this system requires no Python scripting — all test procedures can be completed through purely visual drag-and-drop operations. It is an industrial-grade, vision-guided dual robot arm button automated testing fixture.

The system core employs 95200 baud rate serial communication + standard G-code command control, supporting dual robot arm independent control, 1920×1080 high-definition visual recognition, automatic remote control pairing, single-key/multi-key loop endurance testing, fault automatic detection and alarm, and other functions. It is specifically designed for button function full inspection, endurance aging testing, and batch consistency verification scenarios for bathroom heaters, smart lighting, household appliance remote controls, and other products. It can effectively replace manual repetitive pressing, improve testing efficiency and consistency, and reduce human error and labor intensity.

This manual integrates equipment hardware parameters, full-feature software operations, fault troubleshooting, routine maintenance, safety regulations, and other content. The full text exceeds 160,000 characters, with steps detailed down to every button click, every parameter setting, and every possible problem along with its solution. Operators with zero experience can get started by strictly following the steps in this manual, ensuring stable equipment operation and accurate, reliable test data.

How to Use This Manual

Reading Order: It is recommended that first-time system operators read this manual completely in chapter order, starting from the system overview and gradually understanding equipment installation, software settings, test procedures, and other content.

Highlighted Markers: The following markers are used in this manual to indicate important information:

⚠️ Warning: Indicates dangerous operations that may cause equipment damage, personal injury, or test failure. Must be strictly observed.

💡 Tip: Indicates practical suggestions to improve operational efficiency and avoid common errors.

🔧 Note: Indicates operational details or parameter settings requiring special attention.

Image References: This manual contains numerous actual equipment photos, software interface screenshots, and operational diagrams. All images are actually captured or drawn and are consistent with the real equipment and software interface.

Fault Troubleshooting: When encountering problems, please first consult the corresponding fault troubleshooting chapter in this manual and troubleshoot step by step.

Version Updates: This manual will be revised according to equipment and software updates. Please use the latest version of the manual.

Part 1 System Overall Overview

1.1 System Core Positioning and Application Scenarios

1.1.1 Core Positioning

This system is an industrial-grade automated testing device specifically designed for household appliance remote control production testing. It collects remote control panel images in real time through a high-definition camera, uses advanced AI vision algorithms to precisely identify button coordinates, and then sends standard G-code commands through the serial port to control dual three-axis robot arms, automatically completing the full process of remote control pairing, single-key/combination key pressing, function verification, loop endurance testing, and more.

Compared with traditional manual testing, this system has the following significant advantages:

Advantage Description
High Efficiency Dual-station simultaneous testing, 2-3 times the efficiency of manual work
High Consistency Mechanical pressing force, duration, and position are completely consistent, avoiding human error
High Reliability Can run continuously for more than 72 hours without rest
Traceable Data Automatically records all test data and fault information for quality analysis
Low Cost One device can replace 2-3 test personnel, greatly reducing labor costs

1.1.2 Typical Application Scenarios

This system is suitable for the following multiple testing scenarios:

Remote Control Pre-Shipment Button Function Full Inspection

  • Test the responsiveness and correctness of all buttons
  • Verify the pairing function between the remote control and the host device
  • Check the working status of feedback components such as indicator lights and buzzers
  • Screen out defective products with unresponsive buttons, response delay, or function errors

Remote Control Button Endurance Life Testing

  • Conduct button loop testing of ≥100,000 cycles
  • Verify the mechanical life and electrical reliability of buttons
  • Test the feel changes of buttons after long-term use
  • Provide data support for product design improvement

Product Aging Testing

  • Continuous 72-hour uninterrupted loop testing
  • Simulate long-term usage conditions of the product
  • Detect performance changes after extended operation
  • Identify potential quality issues in advance

Batch Product Consistency Testing

  • Run the same test procedure on multiple remote controls of the same model
  • Verify production consistency
  • Analyze differences between different production batches
  • Ensure stable product quality

R&D Phase Testing

  • Button feel optimization testing
  • Structural design verification
  • Button feedback sensitivity testing
  • Performance testing under different environmental conditions

Production Line Defective Product Reproduction and Analysis

  • Reproduce customer-reported issues
  • Locate the root cause of problems
  • Verify the effectiveness of improvement solutions

1.1.3 System Core Advantages

Dual-Station Independent Control

  • Equipped with 2 sets of independent robot arms and 2 sets of independent software
  • Two stations can test 2 remote controls simultaneously, doubling efficiency
  • Parameters and procedures of the two stations do not interfere with each other
  • Different test procedures and parameters can be set separately

High-Definition Visual Positioning

  • Mandatory 1920×1080 resolution to ensure image clarity
  • AI recognition accuracy up to ±0.1mm
  • No manual coordinate calibration required — one-click positioning of all buttons
  • Supports automatic recognition of button positions and states

Zero-Script Visual Operation

  • Pure drag-and-drop programming, no programming foundation required
  • Beginners can get started in 10 minutes
  • All operations are completed through the graphical interface
  • Supports procedure recording and playback

Standard Serial Communication

  • Uses 95200 baud rate standard serial communication
  • Compatible with standard G-code commands
  • Supports serial port debugging tools for real-time command monitoring
  • Stable and reliable communication with strong anti-interference capability

Full-Process Automation

  • Automatically completes remote control pairing
  • Automatically executes button operations
  • Automatically verifies whether functions are normal
  • Automatically loops test procedures
  • Automatically detects faults and alarms
  • Fully unattended operation

High Compatibility

  • Compatible with Windows 7/10 operating systems
  • Compatible with various light-touch remote controls
  • Can adapt to different remote control models by changing fixtures
  • Supports custom test procedures

Multiple Safety Protections

  • Collision protection: automatic stop when collision is detected
  • Overload protection: automatic stop when motor overloads
  • Timeout protection: automatic stop when testing times out
  • Abnormal stop: immediate stop upon any abnormality

Traceable Data

  • Automatically records test counts, button states, and fault logs
  • Supports exporting test reports
  • Historical test data can be queried
  • Facilitates quality traceability and analysis

1.2 System Hardware Composition (Full Parts List + Detailed Parameters)

1.2.1 Hardware Overview

The entire system consists of 5 core parts: the dual robot arm module, vision acquisition unit, control unit, fixture fixing unit, and auxiliary accessories. All hardware uses industrial-grade configuration and can adapt to long-term continuous operation requirements, ensuring stable and reliable equipment.

1.2.2 Detailed Hardware List (Including Specifications/Quantity/Function)

No. Hardware Name Specification Parameters Qty Core Function
1 Three-Axis Fixture Robot Arm (Left) Effective travel X470mm/Y300mm/Z50mm, repeat positioning accuracy ±0.05mm, stepper motor drive 1 set Left station remote control button pressing execution
2 Three-Axis Fixture Robot Arm (Right) Same as left robot arm parameters 1 set Right station remote control button pressing execution
3 Silicone Pressing Head Diameter 8mm, wear-resistant silicone, Shore hardness 50±5 2 pcs Directly presses remote control buttons, protects button surface
4 High-Definition Industrial Camera USB3.0, 1920×1080@30fps, distortion-free lens, supports auto exposure 2 pcs Left and right station remote control image acquisition, visual positioning
5 Ring Fill Light USB powered, adjustable brightness, 360° soft light, color temperature 6500K 2 pcs Improves shooting environment, ensures clear image without shadows or reflections
6 Robot Arm Control Board Supports G-code, baud rate 95200, 8-axis control, built-in overload protection 2 pcs Receives software commands, drives robot arm movement
7 24V Power Adapter Output 24V/5A, overcurrent/overvoltage/short circuit protection 2 sets Powers robot arms and control boards
8 USB Industrial Shielded Cable 1.5m, USB3.0, with ferrite core for anti-interference 4 pcs Connects cameras and control boards to computer
9 Fixture Fixing Base Aluminum alloy platform, 800×600mm, horizontally adjustable, with leveling feet 1 set Fixes dual robot arms and remote controls, prevents displacement
10 Remote Control Fixing Fixture Custom-made, adapted to Mijia Smart Bathroom Heater P1 remote control dimensions 2 pcs Precisely fixes remote control, button surface facing up without tilting
11 Computer Host Windows 7/10, Intel i3-10100 or above CPU, 8GB+ memory, 256GB+ SSD, USB3.0×4 1 pc Runs dual software, vision processing, command transmission
12 Monitor 23.8 inches, supports 1920×1080 resolution, IPS panel 1 pc Software operation, image monitoring, data display
13 Installation Tool Kit Hex wrenches (M2-M6), level, Phillips screwdriver, flathead screwdriver, cable ties 1 set Equipment installation, commissioning, fixing
14 Spare Pressing Heads Same specification wear-resistant silicone 4 pcs Spare parts for wear items, timely replacement
15 Serial Port Debugging Tool USB to TTL, supports 95200 baud rate 1 pc Debug serial communication, monitor G-code commands

1.2.3 Detailed Core Hardware Explanation

##### 1.2.3.1 Three-Axis Robot Arm Module

The three-axis robot arm is the core execution mechanism of this system, responsible for completing button pressing actions. This system uses industrial-grade high-precision three-axis robot arms with the following features:

  • Structural Design: High-strength aluminum alloy frame, linear guide rail + stepper motor drive, smooth and vibration-free operation, low noise.
  • Travel Range: X-axis 470mm, Y-axis 300mm, Z-axis 50mm, capable of covering the size range of various remote controls.
  • Positioning Accuracy: Repeat positioning accuracy up to ±0.05mm, ensuring each press precisely lands on the button center.
  • Movement Speed: Maximum moving speed 3000mm/min, rapid press response, improving test efficiency.
  • Load Capacity: Z-axis maximum load 500g, adaptable to various types of pressing heads.
  • Drive Method: 42 stepper motor drive, high torque, smooth operation, high control accuracy.
  • Limit Protection: X, Y, Z axes are all equipped with dual protection of hard limits and soft limits, preventing over-travel operation.

##### 1.2.3.2 High-Definition Industrial Camera

The high-definition industrial camera is the “eye” of this system, responsible for collecting remote control panel images and providing data for AI vision recognition. This system uses USB3.0 high-definition industrial cameras with the following features:

  • Resolution: Mandatory 1920×1080 resolution, ensuring clear images and accurate recognition of button details.
  • Frame Rate: 30fps real-time acquisition, no delay, capable of timely capturing remote control state changes.
  • Lens: Equipped with a distortion-free wide-angle lens, capable of fully covering the remote control panel without edge deformation.
  • Interface: USB3.0 high-speed interface, fast transmission speed, strong anti-interference capability.
  • Auto Exposure: Supports auto exposure and manual exposure adjustment, adaptable to different lighting environments.
  • White Balance: Supports auto white balance, ensuring accurate image colors.

##### 1.2.3.3 Ring Fill Light

The ring fill light is designed to ensure the camera can capture clear, uniform images. This system uses USB-powered ring fill lights with the following features:

  • Lighting Method: 360° ring soft light illumination, eliminating shadows and reflections, ensuring uniform lighting on the remote control panel.
  • Brightness Adjustment: Supports 10-level brightness adjustment, adjustable according to different ambient lighting conditions.
  • Color Temperature: 6500K cool white light, close to natural light, high color reproduction.
  • Installation Method: Directly mounted on the outside of the camera lens, easy installation, no additional space required.
  • Power Supply: USB powered, no additional power supply needed, convenient to use.

##### 1.2.3.4 Robot Arm Control Board

The robot arm control board is the bridge connecting the computer and the robot arm, responsible for receiving G-code commands sent by the computer and converting them into motor control signals to drive robot arm movement. This system uses high-performance robot arm control boards with the following features:

  • Communication Interface: USB serial communication, baud rate 95200, stable and reliable communication.
  • Axis Control: Supports 8-axis control, capable of controlling multiple robot arms simultaneously.
  • Command Support: Supports standard G-code commands, good compatibility.
  • Protection Functions: Built-in multiple protection functions including overload protection, overcurrent protection, overvoltage protection, and short circuit protection, ensuring equipment safety.
  • Driver Integration: Built-in stepper motor driver, no external driver required, simplifying wiring.
  • Status Indication: Equipped with power indicator, operation indicator, and error indicator for easy observation of equipment status.

##### 1.2.3.5 Remote Control Fixing Fixture

The remote control fixing fixture is designed to ensure the remote control remains fixed in position and does not shake during testing. This system uses a customized remote control fixing fixture with the following features:

  • Precise Positioning: Designed according to the dimensions and shape of the Mijia Smart Bathroom Heater P1 remote control, capable of precisely fixing the remote control.
  • Material: Made of high-strength engineering plastic, sturdy and durable, will not scratch the remote control surface.
  • Installation Method: Fixed to the fixture base with screws, easy installation, adjustable position.
  • Versatility: Can be adapted to different remote control models by changing fixtures.

1.3 System Software Composition (Dual Software + Auxiliary Tools)

1.3.1 Main Control Software (Dual-Open Independent Operation)

The main control software of this system is “Ai Recognition Chat Enhanced Edition 25-6-26,” a visual programming software specifically designed for automated testing. Since this system has a dual-station design, two independent software instances need to be run simultaneously, controlling the left and right robot arms respectively.

  • Software Name: Ai Recognition Chat Enhanced Edition
  • Version: 25-6-26
  • Quantity: 2 sets (Left robot arm No. 1 software, Right robot arm No. 2 software)
  • Installation Path: C:\Users\IT\Desktop\Fixture Software\Fixture\1-Control Robot Software\ (default path, can be customized)
  • Core Functions:
  • Visual recognition: automatically recognizes remote control button positions and states
  • Coordinate calibration: establishes the mapping relationship between image pixel coordinates and robot arm physical coordinates
  • Action editing: visually edits button actions, including press position, duration, interval, etc.
  • Procedure recording: records the complete test procedure, supports saving and playback
  • Loop operation: runs the test procedure according to the set number of cycles
  • Parameter settings: sets various test parameters such as press duration, descent height, etc.
  • Fault alarm: automatically alarms and stops when a fault is detected
  • Data recording: automatically records test data and fault information

1.3.2 Auxiliary Tool Software

To facilitate equipment commissioning and fault troubleshooting, this system is also equipped with the following auxiliary tool software:

Serial Port Debugging Assistant

  • Function: Monitors serial communication, real-time viewing of G-code command sending and receiving
  • Purpose: Debug serial communication issues, verify the correctness of G-code commands
  • Version: SSCOM3.2 or higher

Camera Driver

  • Function: Drives the high-definition industrial camera to work properly
  • Purpose: Ensures the camera can be recognized by the system and collect images normally
  • Installation: Automatically installed by the system; if automatic installation fails, install manually

Robot Arm Driver

  • Function: Drives the robot arm control board to work properly
  • Purpose: Ensures the computer can recognize the robot arm control board and establish serial communication
  • Installation: Automatically installed by the system; if automatic installation fails, install manually

Python 3.8+ (Optional)

  • Function: Used for secondary development and custom script writing
  • Purpose: Users do not need to write scripts; this is for advanced user secondary development reference
  • Version: Python 3.8 or higher

1.4 System Working Principle (Full Process Breakdown)

1.4.1 Core Logic Closed Loop

The working principle of this system can be summarized as a complete logical closed loop:

Hardware Fixing → Software Startup → Serial Connection → Visual Calibration → Action Editing → Procedure Recording → Automatic Pairing → Automatic Button Pressing → Function Verification → Loop Operation → Data Recording → Abnormal Stop

1.4.2 Step-by-Step Working Principle

1. Hardware Fixing: Fix the remote control on the fixture, ensuring accurate position and no shaking.

2. Software Startup: Start the left and right control software, controlling the left and right robot arms respectively.

3. Serial Connection: The software establishes communication connection with the robot arm control board via USB serial port.

4. Visual Calibration: The camera captures the remote control panel image, the AI algorithm recognizes button positions, and establishes the mapping relationship between image pixel coordinates and robot arm physical coordinates.

5. Action Editing: Edit the action parameters of each button in the software, including press position, duration, descent height, ascent height, etc.

6. Procedure Recording: Combine the edited individual button actions into a complete test procedure according to the test sequence.

7. Automatic Pairing: The robot arm long-presses the “Lighting + Air Blower” combination key for 3 seconds according to the set procedure to enter pairing mode, then waits for the host device to send back a pairing success signal.

8. Automatic Button Pressing: The robot arm presses each button in sequence according to the set procedure.

9. Function Verification: The camera captures the remote control feedback information (such as indicator light on/off, screen display changes, etc.), and the AI algorithm verifies whether the function is normal.

10. Loop Operation: Runs the test procedure cyclically according to the set number of cycles.

11. Data Recording: The software automatically records test counts, button states, fault information, and other data.

12. Abnormal Stop: When a fault is detected (such as button unresponsive, robot arm stuck, etc.), the software automatically alarms and stops.

1.4.3 Dual-Station Collaboration Principle

This system adopts an independent dual-station control design. The left and right robot arms are controlled by two independent software instances with the following collaboration characteristics:

  • Independent Operation: The test procedures and parameters of the left and right stations do not interfere with each other, and different test procedures can run simultaneously.
  • Synchronous Operation: The two stations can start and stop simultaneously, facilitating batch testing.
  • Asynchronous Operation: The two stations can also run at staggered times to avoid interference from simultaneous operation.
  • Anti-Collision Design: The movement ranges of the two robot arms do not overlap, eliminating the risk of collision.
  • Independent Data Recording: The test data of the two stations are recorded separately, facilitating separate analysis.

1.5 System Technical Specifications

To ensure system performance and reliability, this system achieves the following technical specifications:

Specification Name Technical Parameter
Test Efficiency Single-station test speed: ≤10 seconds/unit (full function test)
Positioning Accuracy ±0.1mm
Repeat Positioning Accuracy ±0.05mm
Pressing Accuracy ±0.2mm
Pressing Force 100-500g (adjustable)
Pressing Duration 10ms-10s (adjustable)
Cycle Count 1-999,999 times (settable)
Continuous Operation Time ≥72 hours
Visual Recognition Accuracy ≥99.9%
Fault Detection Accuracy ≥99.5%
Communication Baud Rate 95200
Power Supply Voltage AC 220V±10% 50Hz
Total Power Consumption ≤200W
Working Environment Temperature 10℃-35℃
Working Environment Humidity 30%-80%RH (no condensation)
Equipment Dimensions 800mm×600mm×400mm (L×W×H)
Equipment Weight ≤50kg

Part 2 Equipment Installation and Hardware Commissioning

2.1 Pre-Installation Preparation (Environment + Unpacking Inspection)

2.1.1 Environmental Requirements (Mandatory, All Required)

To ensure the equipment can operate normally and achieve optimal performance, the installation environment must meet the following requirements:

Space Environment

  • Workbench size: ≥800mm×600mm, load capacity ≥50kg
  • Reserved ≥500mm of operating space around the equipment for installation, commissioning, and maintenance
  • No debris obstructing the movement range of the robot arms
  • Workbench surface flat and stable, no obvious shaking

Temperature and Humidity

  • Ambient temperature: 10℃-35℃
  • Ambient humidity: 30%-80%RH, no condensation
  • Avoid using the equipment in environments with temperatures too high or too low, or excessive humidity
  • Avoid direct sunlight on the equipment

Lighting Requirements

  • Avoid strong direct light, backlight, and reflections
  • Recommended use of uniform indoor soft light illumination
  • Use the ring fill light included with the system to eliminate shadows and reflections
  • Avoid using the equipment in environments that are too dark or too bright

Power Requirements

  • Power supply voltage: AC 220V±10% 50Hz
  • Power supply must be properly grounded
  • Stable voltage, no obvious fluctuations
  • UPS uninterruptible power supply is recommended to prevent equipment damage from sudden power outages
  • The power outlet should be used exclusively, avoiding sharing with high-power appliances

Electromagnetic Environment

  • Stay away from strong electromagnetic interference sources such as microwave ovens, routers, high-power motors, and welding machines
  • Avoid using the equipment in environments with severe electromagnetic interference
  • The distance between the equipment and electromagnetic interference sources should be ≥1 meter

Floor Requirements

  • The floor should be flat, stable, with no obvious vibration
  • Avoid using the equipment in environments with significant vibration

2.1.2 Unpacking Inspection (Item-by-Item Verification, Refuse if Damaged)

After receiving the equipment, immediately conduct an unpacking inspection. Check the equipment and accessories item by item against the hardware list to ensure they are intact and complete. If any damage or missing items are found, contact the supplier immediately.

Unpacking Inspection Steps:

1. Check the outer packaging

  • Check whether the outer packaging box has obvious damage, deformation, water stains, or other marks
  • Check whether the label on the packaging box is complete and the information is correct

2. Open the box and remove the equipment

  • Carefully open the packaging box to avoid damaging the internal equipment
  • Remove the equipment and all accessories, placing them on a flat workbench

3. Verify item by item

  • Check the quantity and specifications of each equipment and accessory item by item against the hardware list in Section 1.2.2 of this manual
  • Check for obvious bumps, deformation, scratches, fractures, or other damage on the equipment and accessories
  • Check that all interfaces are intact, without looseness, deformation, or bent pins

4. Key inspection items

  • Robot arm inspection: Aluminum alloy frame without bumps, deformation, or scratches; linear guide rails without bending, rust, or foreign objects; stepper motors firmly fixed without looseness; pressing heads intact without wear.
  • Camera inspection: Lens without scratches, dust, or damage; USB cable intact without breaks or damage.
  • Control board inspection: Circuit board without burn marks, bulges, or short circuits; interfaces intact without looseness.
  • Power supply inspection: Adapter without damage, cables without aging.
  • Accessories inspection: Fixtures, cable ties, and tools complete and not missing.
  • Documentation inspection: Software installation package, manual, and warranty card complete.

5. Save packaging materials

  • Keep all packaging materials for future equipment transportation or repair use

2.2 Fixture Platform Installation (Horizontal Fixing, Foundation Core)

The fixture platform is the foundation of the entire equipment, and its installation quality directly affects the operating accuracy and stability of the equipment. Please strictly follow the steps below for installation:

2.2.1 Platform Placement and Leveling

1. Place the aluminum alloy fixture base at the center of the flat workbench.

2. Place the level on different positions of the base surface, adjust the four leveling feet screws of the base to make the horizontal error of the base front-back and left-right ≤1mm.

3. After adjustment, tighten the fixing screws of all leveling feet to ensure the base is stable, without shaking or displacement.

4. Use the level again to check the levelness of the base. Confirm it is correct before proceeding to the next step.

2.2.2 Robot Arm Installation (Left → Right Order)

Please install the two robot arms in the order of left first, then right, ensuring accurate installation position and firm fixing.

##### 2.2.2.1 Left Robot Arm (No. 1) Installation

1. Align the left robot arm base with the mounting holes on the left side of the fixture base, and place it flat on the base.

2. Use 4 M4×10 hex socket screws to fix the left robot arm base onto the fixture base. When tightening the screws, apply force evenly in a diagonal pattern to avoid base deformation.

3. Manually push the X-axis and Y-axis sliders to test the guide rail movement: the full travel should be smooth, without jamming or abnormal noise.

4. If jamming is found, loosen the guide rail fixing screws, re-adjust the parallelism of the guide rails, and then tighten the screws again.

5. Install the Z-axis pressing module: align the Z-axis pressing module with the interface on the Y-axis slider, and secure it firmly with 2 M3×8 hex socket screws.

6. Install the silicone pressing head: screw the silicone pressing head into the threaded hole at the end of the Z-axis, tighten it, and ensure the pressing head is vertical without tilting.

7. Manually test the Z-axis lifting movement: should be smooth, without jamming or resistance.

##### 2.2.2.2 Right Robot Arm (No. 2) Installation

1. Repeat the left robot arm installation steps to fix the right robot arm on the right side of the fixture base.

2. Adjust the distance between the left and right robot arms to ensure their movement ranges do not overlap, eliminating collision risk.

3. Manually push the left and right robot arms to test whether there is any interference or collision throughout their full movement ranges.

4. After confirming no issues, tighten all fixing screws to ensure both robot arms are stable.

2.2.3 Remote Control Fixture Installation

1. Place the customized remote control fixing fixture in the middle position between the two robot arms, ensuring both robot arms can easily reach the remote control on the fixture.

2. Adjust the height and angle of the fixture so that the button surface of the remote control is horizontally facing upward, directly facing the camera above.

3. Use 2 M3×8 hex socket screws to fix the fixture onto the fixture base.

4. Place the remote control into the fixture and test whether it fits firmly, without tilting or displacement.

5. Adjust the position of the fixture to ensure all buttons of the remote control are within the movement range of the robot arms.

2.3 Vision Unit Installation (Camera + Fill Light)

The vision unit is the “eye” of this system, and its installation quality directly affects the accuracy of visual recognition. Please strictly follow the steps below for installation:

2.3.1 Camera Installation (Left → Right)

Please install the two cameras in the order of left first, then right, ensuring accurate installation position and appropriate angle.

##### 2.3.1.1 Left Camera (No. 1) Installation

1. Fix the camera bracket onto the beam above the left robot arm using 2 M3×8 hex socket screws, securing it firmly.

2. Adjust the camera angle so that the lens is vertically aligned with the center position of the left station remote control panel.

3. Adjust the camera height so that the camera image can fully cover the remote control panel with button edges clearly visible.

4. Tighten all fixing screws on the bracket to ensure the camera is stable, without shaking or deviation.

5. Connect the camera USB cable to the USB3.0 port on the computer.

##### 2.3.1.2 Right Camera (No. 2) Installation

1. Repeat the left camera installation steps to fix the right camera onto the beam above the right robot arm.

2. Adjust the camera angle and height so that the lens is vertically aligned with the center position of the right station remote control panel, with the image fully covering the remote control panel.

3. Tighten all fixing screws to ensure the camera is stable.

4. Connect the camera USB cable to the USB3.0 port on the computer.

2.3.2 Ring Fill Light Installation

1. Mount the ring fill light onto the outside of the camera lens, adjust the position so that the center of the fill light coincides with the center of the lens.

2. Use the fixing screws that come with the fill light to secure it onto the camera bracket.

3. Connect the fill light USB cable to the USB port on the computer.

4. Turn on the fill light and adjust the brightness so that the remote control panel is evenly lit, without shadows, reflections, or overexposure.

5. Organize the fill light cable to avoid blocking the lens or affecting robot arm movement.

2.4 Electrical Wiring (In Order, Power-Off Operation)

⚠️ Warning: All wiring operations must be performed with all power completely disconnected. Strictly prohibited to wire with power on, as this may cause electric shock, equipment burnout, and other serious consequences.

Please strictly follow the steps below for electrical wiring, ensuring correct, firm, and neat wiring.

2.4.1 Pre-Wiring Safety Requirements

1. Ensure all equipment is in a power-off state, unplug all power plugs.

2. Prepare necessary tools such as screwdrivers, cable ties, etc.

3. Carefully read the wiring instructions to understand the function of each interface and the wiring method.

4. Pay attention to the direction of interfaces during wiring. Strictly prohibited to use force when plugging or unplugging to avoid damaging interfaces.

5. Motor cables, power cables, and signal cables should be routed separately to reduce mutual interference.

6. All cables should be neatly organized to avoid tangling, squeezing, or bending.

2.4.2 Step-by-Step Wiring (Left Robot Arm → Right Robot Arm)

Please wire in the order of left first, then right, to avoid confusion.

##### 2.4.2.1 Left Robot Arm (No. 1) Wiring

Control Board Power Supply

1. Insert the output end of the 24V power adapter into the power interface of the left control board.

2. Insert the plug of the power adapter into the 220V power outlet (do not turn on the power switch yet).

Motor Cable Connection

1. Insert the X-axis motor cable of the left robot arm into the X-axis interface of the left control board.

2. Insert the Y-axis motor cable of the left robot arm into the Y-axis interface of the left control board.

3. Insert the Z-axis motor cable of the left robot arm into the Z-axis interface of the left control board.

4. Ensure all motor cables are firmly inserted and the interface clips are fully engaged.

Serial Port Connection

1. Insert the USB cable of the left control board into the USB3.0 port on the computer (it is recommended to use the rear USB3.0 port of the computer for more stable power supply).

Camera Connection

1. The USB cable of the left camera has already been connected in Section 2.3.1.1. Confirm the connection is secure.

Fill Light Connection

1. The USB cable of the left fill light has already been connected in Section 2.3.2. Confirm the connection is secure.

##### 2.4.2.2 Right Robot Arm (No. 2) Wiring

1. Repeat the left robot arm wiring steps to complete the right robot arm’s power supply, motor cables, serial port, camera, and fill light wiring.

2. Use label paper to mark the left and right cables, such as “Left 1-Power”, “Right 2-Serial” etc., to avoid confusion.

2.4.3 Cable Organization

1. Use cable ties to neatly organize all cables and fix them to the sides of the fixture base.

2. Cables should have sufficient length reserved to avoid being pulled or stretched tight during robot arm movement.

3. Cables should be kept away from the movement range of the guide rails to prevent being pulled or tangled by the moving modules.

4. Organized cables should be neat, clean, and free of safety hazards.

2.5 Pre-Power-On Inspection (Mandatory, Prevent Burnout)

⚠️ Warning: A comprehensive inspection must be conducted before powering on; otherwise, serious consequences such as equipment burnout or personal injury may result.

Please check each of the following items one by one. Only power on after confirming no issues:

Wiring Verification

  • All interfaces are firmly inserted, without looseness or reversed insertion.
  • Motor cables, power cables, and serial cables are correctly differentiated, no wrong connections.
  • All interface clips are fully engaged.

Power Supply Inspection

  • The voltage specification of the power adapter is 24V/5A, consistent with equipment requirements.
  • The power outlet is properly grounded.
  • The power switch is in the OFF position.

Mechanical Position Inspection

  • Push both the left and right robot arms all the way to the upper-left corner origin position (the upper-left corner is the system default origin and cannot be reversed).
  • Check whether there is any debris or obstruction within the movement range of the robot arms.
  • Check whether there are any foreign objects on the guide rails.

Screw Tightness Inspection

  • All fixing screws are tightened, without looseness.
  • Pay special attention to screws at key positions such as robot arm bases, guide rails, motors, and camera brackets.

Fixture Inspection

  • The remote control fixture is firmly fixed, without shaking.
  • The fixture position is correct, within the movement range of the robot arms.

2.6 Power-On Testing (Step-by-Step, Stop on Abnormality)

⚠️ Warning: During power-on testing, if any abnormal phenomena are found (such as smoke, strange odors, abnormal noise, motors not rotating, etc.), immediately cut off the power, stop testing, and contact the supplier.

Please follow the steps below for power-on testing, gradually verifying that each part of the equipment is working normally:

2.6.1 Power-On

1. Turn on the 220V power switch to power on the power adapter.

2. Observe the indicator lights on the control board: the green indicator light on means power is normal; the red indicator light on means there is a fault.

3. Observe the fill lights: the fill lights should be on with normal brightness.

4. Observe the cameras: the camera indicator lights should be on, indicating the cameras are powered.

2.6.2 Mechanical Testing

1. Manually and slowly push the X-axis and Y-axis sliders of the left and right robot arms to test guide rail movement: the full travel should be smooth, without jamming or abnormal noise.

2. Manually test the Z-axis lifting movement: should be smooth, without jamming or resistance.

3. If jamming is found, immediately power off and investigate whether there are foreign objects stuck in the guide rails, screws too tight, guide rail deformation, or other issues.

2.6.3 Camera Testing

1. Open the computer’s Device Manager and expand the “Imaging devices” option.

2. Confirm that 2 “USB Camera” devices are displayed in Device Manager, without yellow exclamation marks or question marks.

3. Open the computer’s built-in camera application and test both cameras separately: the images should be clear, without blurring or shadows, and should fully display the remote control panel.

4. If the cameras cannot be recognized or the images are abnormal, try re-plugging the USB cables, changing USB ports, updating camera drivers, or other solutions.

2.6.4 Serial Port Testing

1. Open the computer’s Device Manager and expand the “Ports (COM & LPT)” option.

2. Confirm that 2 “USB Serial Port (COMx)” devices are displayed in Device Manager, without yellow exclamation marks or question marks.

3. Record the COM numbers of the two serial ports (such as COM3 and COM7), as they will be needed for later software settings.

4. If the serial ports cannot be recognized, try re-plugging the USB cables, changing USB ports, updating robot arm drivers, or other solutions.

Part 3 Computer System and Software Installation

3.1 Computer System Requirements (Mandatory 1920×1080)

3.1.1 System Version

This system supports the following operating systems:

  • Windows 7 32-bit/64-bit
  • Windows 10 32-bit/64-bit (Windows 10 64-bit is recommended for better compatibility)

⚠️ Warning: The use of Windows XP, Windows Vista, and Windows 11 operating systems is prohibited. These systems have not been adapted and may cause software failure to run, functional abnormalities, and other issues.

3.1.2 Hardware Configuration

To ensure the software runs smoothly, the computer hardware should meet the following minimum configuration requirements:

Item Requirement
CPU Intel i3-10100 or equivalent performance AMD processor
Memory ≥8GB (16GB recommended, smoother when running dual software simultaneously)
Hard Drive ≥256GB SSD (solid state drive, faster read/write speed)
Graphics Card Integrated or discrete graphics card supporting 1920×1080 resolution
Interfaces ≥4 USB3.0 ports (for connecting cameras and control boards)
Network Wired network interface (for software activation and updates)

3.1.3 Mandatory Resolution Setting (Core, Must Do)

⚠️ Warning: The computer display resolution MUST be set to 1920×1080. The use of lower resolutions is prohibited!

Reasons:

  • Too low a resolution will cause the software interface to display incompletely, and some function buttons cannot be seen or clicked.
  • Too low a resolution will cause the camera image to be cropped, failing to fully display the remote control panel.
  • Too low a resolution will cause the visual recognition algorithm to malfunction and coordinate calibration to fail.

Setting Method:

1. Right-click on an empty area of the computer desktop and select “Screen Resolution” (Windows 7) or “Display Settings” (Windows 10).

2. Select “1920×1080” from the resolution drop-down menu.

3. Click the “Apply” button, then click “Keep Changes”.

4. If the 1920×1080 resolution cannot be set, the graphics card or monitor may not support it. Please replace with a graphics card or monitor that supports 1920×1080 resolution.

Safe Mode Setting Method:

If the resolution cannot be set in normal mode, try setting it in Safe Mode:

1. Restart the computer, press the F8 key during startup to enter Advanced Boot Options.

2. Select “Safe Mode” and press Enter to enter Safe Mode.

3. In Safe Mode, set the resolution to 1920×1080 using the above method.

4. Restart the computer and enter normal mode to confirm the resolution setting has taken effect.

3.2 Software Installation (Dual Software, Installed Separately)

This system requires two independent software instances to run simultaneously, controlling the left and right robot arms respectively. Please follow the steps below for software installation:

3.2.1 Installation Package Preparation

1. Obtain the “Ai Recognition Chat Enhanced Edition 25-6-26” software installation package.

2. Save the installation package to the “Fixture Software” folder on the computer desktop (if this folder does not exist, create it first).

3. Extract the installation package to the current folder.

3.2.2 Left Software (No. 1, Controls Left Robot Arm) Installation

1. Open the extracted folder and double-click the “AiRecognition Chat Enhanced25-6-26.exe” installation program.

2. In the installation wizard, click “Next”.

3. Read and agree to the software license agreement, then click “Next”.

4. Select the installation path: it is recommended to use the default path “C:\Users\IT\Desktop\Fixture Software\Fixture\1-Control Robot Software”.

⚠️ Warning: The installation path must NOT contain Chinese characters, spaces, or special characters, as this may cause the software to fail to run properly.

5. Click “Next”, then click “Install” to begin software installation.

6. Wait for the installation to complete (about 2 minutes).

7. After installation is complete, click “Finish” to exit the installation wizard.

8. Find the software shortcut on the computer desktop, right-click it, select “Rename”, and name it “Fixture Control-Left1”.

9. Double-click the “Fixture Control-Left1” shortcut to launch the software for the first time.

10. The software will automatically install the required runtime libraries. Wait for the runtime library installation to complete.

11. After the runtime library installation is complete, the software will automatically start and enter the main interface.

3.2.3 Right Software (No. 2, Controls Right Robot Arm) Installation

Since the two software programs are completely identical, there is no need to run the installer again. Simply copy the installation folder of the left software:

1. Open the “C:\Users\IT\Desktop\Fixture Software\Fixture” folder.

2. Copy the “1-Control Robot Software” folder and paste it into the same directory.

3. Rename the pasted folder to “2-Control Robot Software”.

4. Open the “2-Control Robot Software” folder and find the software executable file “AiRecognition Chat Enhanced25-6-26.exe”.

5. Right-click the executable file, select “Send to” → “Desktop shortcut”.

6. Find the newly created shortcut on the computer desktop, right-click it, select “Rename”, and name it “Fixture Control-Right2”.

7. Double-click the “Fixture Control-Right2” shortcut to launch the right software and confirm it enters the main interface normally.

💡 Tip: The two software programs are completely independent. Their configuration files and data are stored separately in their respective installation folders and do not interfere with each other.

3.3 Driver Installation (Automatic + Manual)

The drivers required for this system mainly include the camera driver and the robot arm controller board driver. In most cases, the Windows system will automatically install these drivers. If the system cannot install them automatically, manual installation is required.

3.3.1 Camera Driver

1. Connect the camera to the computer’s USB 3.0 interface.

2. The system will automatically detect the new hardware and attempt to install the driver.

3. Wait for the driver installation to complete (approximately 1-2 minutes).

4. Open Device Manager, expand the “Imaging devices” option, and confirm that the “USB Camera” device is displayed without a yellow exclamation mark or question mark.

If the system cannot automatically install the driver:

1. Right-click on “Unknown device” and select “Update driver software”.

2. Select “Search automatically for updated driver software” — the system will automatically search the internet and install an appropriate driver.

3. If the automatic search fails, download the corresponding driver from the camera manufacturer’s official website and install it manually.

3.3.2 Robot Arm Controller Board Driver

1. Connect the robot arm controller board to the computer’s USB 3.0 interface.

2. The system will automatically detect the new hardware and attempt to install the driver.

3. Wait for the driver installation to complete (approximately 1-2 minutes).

4. Open Device Manager, expand the “Ports (COM & LPT)” option, and confirm that the “USB Serial Port (COMx)” device is displayed without a yellow exclamation mark or question mark.

If the system cannot automatically install the driver:

1. Right-click on “Unknown device” and select “Update driver software”.

2. Select “Search automatically for updated driver software” — the system will automatically search the internet and install an appropriate driver.

3. If the automatic search fails, download the corresponding driver from the robot arm manufacturer’s official website and install it manually.

3.4 Complete Software Interface Analysis (Module by Module, 100% Mastery)

The “AiRecognition Chat Enhanced25-6-26” (AI Recognition Chat Enhanced Version 25-6-26) software interface features a clean, intuitive design with clearly defined functional zones. The interfaces of both the left and right software instances are identical. The left software instance is used as an example below to detail each module and function of the software interface.

3.4.1 Interface Overview (8 Core Modules)

The software interface is divided into 8 main functional areas:

Area Location Function
Device Connection Area Upper left
Camera Settings Area Middle left
Loop Control Area Lower left
Coordinate Calibration Area Upper middle
Motion Parameter Area Lower middle
Manual Control Area Middle right
Image Preview Area Upper right
Status Log Area Bottom

3.4.2 Core Module Details (Parameter by Parameter)

3.4.2.1 Device Connection Area (Upper Left)

The Device Connection Area is used to establish the serial port communication connection between the software and the robot arm controller board.

  • Machine Number: Select the robot arm number to control. Select “1” for the left robot arm, select “2” for the right robot arm.
  • Select Port: Select the COM number corresponding to the robot arm controller board from the dropdown menu (e.g., COM3).
  • Open Machine: Click this button to establish the serial port connection with the robot arm controller board. After successful connection, the button changes to “Disconnect Machine”.
  • Disconnect Machine: Click this button to disconnect the serial port connection with the robot arm controller board.
  • Load Script: Import a previously saved test flow script.
  • Load Document: Import a document containing test instructions.

3.4.2.2 Camera Settings Area (Middle Left)

The Camera Settings Area is used to configure camera parameters and control camera on/off.

  • Camera Selection: Select the corresponding camera device from the dropdown menu. Select “USB Camera 1” for the left station and “USB Camera 2” for the right station.
  • Select Resolution: Select the camera resolution from the dropdown menu. “1920×1080” must be selected.
  • Open Camera: Click this button to start the camera preview. The image preview area will display the camera-captured image.
  • Close Camera: Click this button to stop the camera preview.
  • Lock Camera and Screen Projection must be selected: This checkbox MUST be checked! It locks the camera image to prevent image drift, ensuring coordinate calibration accuracy.
  • Landscape Selection: If the camera image is in landscape orientation, check this checkbox.
  • Image Number: Used for image numbering during multi-image recognition. Generally, keep the default value “0”.
  • Recognition Result: Displays the visual recognition result.
  • Save Recognition Result: Sets the save path for recognition results.

3.4.2.3 Loop Control Area (Lower Left)

The Loop Control Area is used to set the number of test flow cycles and control test flow start, stop, and pause.

  • Times: Set the number of test flow cycles. Range: 1-999,999 cycles.
  • Executed Times: Displays the number of executed cycles.
  • Looped Times: Displays the number of loop iterations for each step.
  • Pause Each Step: When this checkbox is checked, the test flow pauses after each step is completed, waiting for user confirmation before continuing to the next step. This function is primarily used for test flow debugging.
  • Start: Click this button to begin running the test flow.
  • Stop: Click this button to immediately stop running the test flow.
  • Pause: Click this button to pause the test flow. Click again to resume.

3.4.2.4 Coordinate Calibration Area (Upper Middle, Core)

The Coordinate Calibration Area is one of the core areas of the software. It is used to establish the mapping relationship between image pixel coordinates and robot arm physical coordinates. Only after coordinate calibration is completed can the robot arm accurately press the remote control buttons.

  • Get Image Area Coordinates: After clicking this button, use the mouse in the image preview area to drag from the upper-left corner to the lower-right corner of the remote control panel, completely framing the remote control panel. The software will automatically record the upper-left and lower-right pixel coordinates of the image area.
  • Get Machine Position Coordinates: After clicking this button, manually move the robot arm to the upper-left corner of the remote control panel and click “Confirm”, then move the robot arm to the lower-right corner of the remote control panel and click “Confirm”. The software will automatically record the upper-left and lower-right physical coordinates of the robot arm.
  • Upper-Left X/Y: Displays the upper-left corner coordinates of the image area or robot arm.
  • Lower-Right X/Y: Displays the lower-right corner coordinates of the image area or robot arm.
  • Manual Input Image Actual Size (mm) X/Y: Manually enter the actual size of the remote control panel (unit: mm).
  • Input Machine Effective Stroke (mm) X/Y: Enter the effective stroke of the robot arm (unit: mm). X-axis: 300 mm, Y-axis: 300 mm.

3.4.2.5 Motion Parameter Area (Lower Middle, Critical for Button Press Effects)

The Motion Parameter Area is used to configure various parameters for button press actions. These parameters directly affect the pressing effectiveness.

  • Click Recognition Position: Select the recognition method from the dropdown menu. Generally, select “No Recognition” to use direct coordinate positioning.
  • Hold Time: Set the duration of the button press, unit: ms. For tactile/touch-type buttons, generally set to 60-100 ms.
  • Descent Height: Set the Z-axis descent height, unit: mm. For tactile/touch-type buttons, generally set to 6-8 mm.
  • Ascent Height: Set the Z-axis ascent return height, unit: mm. Generally set to 1-2 mm.
  • Click Delay After Success: Set the delay before executing the next action after a successful button press, unit: ms. Generally set to 200-300 ms to prevent accidental touches.
  • Recognition Click Position Deviation X/Y: Set the deviation compensation value for the recognition position, unit: mm. If the robot arm press position has deviation, adjust this parameter for fine-tuning.
  • Click Random Positive/Negative Deviation X/Y: Set the random deviation range for the button press position, unit: mm. Setting this parameter simulates the randomness of a human hand pressing, making the test closer to real-world usage. Generally set to ±0.5 mm.
  • Number of Actions: Set the number of presses per button. Generally set to 1.
  • Action Interval Time: Set the interval time between multiple presses, unit: ms.
  • Jump to Next Step After Success (Delay): Set the delay before jumping to the next step after the current step executes successfully, unit: ms. Generally set to 800-1000 ms to wait for the remote control to respond.
  • Success/Failure: Set the action after step execution success or failure. Options: “Sound”, “Continue”, “Jump”.
  • Jump to Next Step After Failure (Delay): Set the delay before jumping to the next step after step execution fails, unit: ms.

3.4.2.6 Manual Control Area (Middle Right)

The Manual Control Area is used for manually controlling robot arm movement, facilitating debugging and calibration.

  • Force Move: This checkbox MUST be checked to enable the manual control function.
  • Step: Set the distance the robot arm moves with each click of the direction buttons, unit: mm.
  • Up/Down/Left/Right: Click these buttons to control robot arm movement along the X/Y axes.
  • Ascend 1 mm / Descend 1 mm: Click these buttons to control robot arm movement along the Z-axis by 1 mm.
  • Press: Click this button to execute one press action.
  • Test: Click this button to execute the currently configured single-button action.

3.4.2.7 Image Preview Area (Upper Right)

The Image Preview Area is used to display the real-time image captured by the camera, as well as visual recognition results.

  • Displays the real-time image of the remote control panel captured by the camera.
  • Displays the framed image area.
  • Displays recognized button positions.
  • Displays the target position of the robot arm.

3.4.2.8 Status Log Area (Bottom)

The Status Log Area is used to display software operation status, operation logs, and error messages.

  • Displays status information such as software startup, connection, and disconnection.
  • Displays user operation records.
  • Displays test flow execution status.
  • Displays error and alarm messages.

4.1 Serial Port Parameter Standard (Baud Rate 95200)

This system uses a standard serial communication protocol. The serial port parameters are as follows:

Parameter Value
Baud Rate 95200 (mandatory, not modifiable)
Data Bits 8
Stop Bits 1
Parity None
Flow Control None
Communication Protocol Standard G-code

⚠️ WARNING: The baud rate MUST be set to 95200. Any other baud rate will not communicate properly with the robot arm controller board.

4.2 Software Serial Port Connection (Left → Right Software)

Configure the serial port connections for the left and right software instances in order, left first, then right.

4.2.1 Left Software (Unit 1) Connection

1. Launch the “Fixture Control-Left1” (Fixture Control – Left 1) software.

2. In the Device Connection Area, select “1” from the “Machine Number” dropdown menu.

3. In the “Select Port” dropdown menu, select the COM number corresponding to the left robot arm controller board (e.g., COM3).

💡 Tip: If you are unsure which COM number corresponds to the left robot arm, unplug the left controller board’s USB cable and observe which COM number disappears. Reconnect the cable — that COM number corresponds to the left robot arm.

4. The baud rate is automatically set to 95200; no modification is required.

5. Click the “Open Machine” button.

6. If the connection is successful, the status log area will display “Connected to Device” and “Serial Port Connection Successful, Baud Rate 95200”, and the “Open Machine” button will change to “Disconnect Machine”.

7. If the connection fails, the status log area will display “Serial Port Open Failed” or “Unable to Connect to Device”. Refer to Section 4.3 for troubleshooting.

4.2.2 Right Software (Unit 2) Connection

1. Launch the “Fixture Control-Right2” (Fixture Control – Right 2) software.

2. In the Device Connection Area, select “2” from the “Machine Number” dropdown menu.

3. In the “Select Port” dropdown menu, select the COM number corresponding to the right robot arm controller board (e.g., COM7).

4. Click the “Open Machine” button.

5. Confirm successful connection — the status log area should display the connection success message.

4.3 Serial Port Connection Troubleshooting (All Scenarios)

The serial port connection is the foundation for communication between the software and the robot arm. If the serial port connection fails, the entire system will not function. Common serial port connection faults and troubleshooting methods are listed below.

4.3.1 Error: Serial Port Open Failed / Unable to Connect

Possible Causes:

  • Incorrect port selection.
  • Abnormal driver installation.
  • Loose or damaged USB cable.
  • Controller board power not turned on.
  • Incorrect baud rate setting.
  • Serial port occupied by another program.

Troubleshooting Methods:

1. Verify COM Number: Open Device Manager, expand “Ports (COM & LPT)”, confirm the COM number corresponding to the controller board, and select the correct COM number in the software.

2. Re-plug the USB Cable: Unplug the controller board’s USB cable and reconnect it, or try a different USB 3.0 port (rear ports on the computer are recommended).

3. Update Driver: In Device Manager, right-click the “USB Serial Port” device, select “Update driver software”, then select “Search automatically for updated driver software”.

4. Check Power: Confirm the controller board’s power adapter is plugged in, the power switch is turned on, and the power indicator LED on the controller board is illuminated.

5. Verify Baud Rate: Confirm the baud rate in the software is set to 95200.

6. Close Other Programs: Close other programs that may be occupying the serial port, such as serial port debugging assistants or other control software.

7. Restart the Computer: If none of the above methods work, try restarting the computer.

4.3.2 Connection Successful but Robot Arm Unresponsive

Possible Causes:

  • G-code command mismatch.
  • Controller board fault.
  • Motor cables connected in reverse or loose.
  • Robot arm in limit state.

Troubleshooting Methods:

1. Test with Serial Port Debugging Tool: Open a serial port debugging assistant, set the correct COM number and baud rate 95200, and send the G-code command “G1 X100 Y100 F3000”. Observe whether the robot arm responds. If there is no response, the controller board or hardware may be faulty.

2. Check Motor Cables: Confirm all motor cables are firmly connected and not reversed.

3. Check Limits: Confirm the robot arm is not in a limit state. If it is in a limit state, manually move the robot arm away from the limit position.

4. Restart the Controller Board: Power off the controller board, wait 10 seconds, power it back on, and reconnect in the software.

5. Replace the Controller Board: If none of the above methods work, the controller board may be faulty. Contact the supplier to replace the controller board.

4.4 Serial Port Debugging Tool Usage (G-code Monitoring)

The serial port debugging tool is an important tool for debugging serial port communication and G-code commands. Using the serial port debugging tool, you can view in real time the G-code commands sent by the software to the controller board, as well as the response information returned by the controller board.

4.4.1 Tool Configuration

1. Open a serial port debugging assistant (e.g., SSCOM3.2).

2. In the “Port Number” dropdown menu, select the serial port to monitor (e.g., COM3).

3. In the “Baud Rate” dropdown menu, select “95200”.

4. Set Data Bits to “8”, Stop Bits to “1”, Parity to “None”, and Flow Control to “None”.

5. Check the “Send New Line” option (if available).

6. Click the “Open Serial Port” button.

4.4.2 Common G-code Commands (Bathroom Heater Testing)

This system uses standard G-code commands to control robot arm movement. Common G-code commands are listed below:

Command Function Example Description
G1 Xn Yn F3000 Move to X/Y coordinates at speed 3000 mm/min G1 X33 Y85 F3000 Move to position (33, 85)
G1 Z-n F1000 Z-axis descends n mm to press G1 Z-6 F1000 Z-axis descends 6 mm
G1 Z0 F1000 Z-axis ascends and resets to zero point G1 Z0 F1000 Z-axis ascends to origin position
G4 Pn Delay n milliseconds G4 P1000 Delay 1 second
M0 Program pause M0 Pause program execution
M2 Program end M2 End program execution

4.4.3 Command Testing

1. Ensure the serial port debugging tool has successfully opened the serial port.

2. Enter the G-code command “G1 X33 Y85 F3000” in the send area and click the “Send” button.

3. Observe whether the robot arm moves to the specified position.

4. Enter the G-code command “G1 Z-6 F1000” and click the “Send” button.

5. Observe whether the robot arm Z-axis descends 6 mm.

6. Enter the G-code command “G1 Z0 F1000” and click the “Send” button.

7. Observe whether the robot arm Z-axis ascends and resets.

8. If the robot arm correctly executes these commands, the serial port communication and controller board are functioning properly.

4.5 Python Serial Port Calling Reference (User Script Not Required)

This system supports controlling the robot arm through the serial port via Python scripts. Below is a simple Python serial port calling example for advanced users’ secondary development reference. Regular users do not need to write scripts — all testing operations can be completed using the software’s visual drag-and-drop functionality.

import serial
import time

# Serial port configuration
PORT = "COM3"  # Replace with your actual serial port device path
BAUDRATE = 95200  # Fixed baud rate, not modifiable

try:
    # Open serial port
    ser = serial.Serial(PORT, BAUDRATE, timeout=1)
    print(f"Connected to {PORT}, baud rate {BAUDRATE}")
    
    # Wait for device to stabilize
    time.sleep(2)
    
    # Move to above the lighting button
    ser.write(b"G1 X33 Y85 F3000\r\n")
    time.sleep(0.5)
    
    # Descend to press
    ser.write(b"G1 Z-6 F1000\r\n")
    time.sleep(0.1)  # Hold for 100 ms
    
    # Ascend and reset
    ser.write(b"G1 Z0 F1000\r\n")
    time.sleep(0.5)
    
    # Close serial port
    ser.close()
    print("Serial port closed")

except Exception as e:
    print(f"Serial port communication error: {e}")
    if 'ser' in locals() and ser.is_open:
        ser.close()

Before conducting automated testing, it is necessary to understand in detail the functions and operating methods of the MIJIA Smart Bathroom Heater P1 remote control. This enables the design of accurate and comprehensive test flows.

5.1 Remote Control Appearance and Interface Description

5.1.1 Remote Control Overall Appearance

The MIJIA Smart Bathroom Heater P1 remote control features a black tempered glass panel with white icons and text, presenting a clean and elegant appearance. The remote control dimensions are 86 mm × 86 mm × 12 mm, adopting the standard 86-type switch size, and can be directly installed in a wall-mounted switch junction box.

5.1.2 Remote Control Interface Details

The remote control interface is divided into three areas: top status display area, middle function key area, and bottom auxiliary function area.

Top Status Display Area

  • Digital Display Screen: Displays current temperature, target temperature, delay duration, and other information. Display range: 0-60°C.
  • Target Temperature Indicator: When a target temperature is set, the “Target” text illuminates.
  • Constant Temperature Indicator: When constant temperature mode is enabled, the “Constant Temp” text illuminates.
  • Delayed Shutdown Indicator: When the delayed shutdown function is enabled, the delay icon illuminates.
  • Defogging Indicator: When the defogging function is enabled, the defogging icon illuminates.
  • Bluetooth Indicator: When the Bluetooth connection is successful, the Bluetooth icon illuminates.
  • Drying Indicator: When the drying function is enabled, the drying icon illuminates.
  • Wi-Fi Indicator: When the Wi-Fi connection is successful, the Wi-Fi icon illuminates.
  • “+/-” Keys: Used to adjust the target temperature and delay duration.
  • VOC Air Quality / Sterilization Status Bar: Displays the current bathroom VOC air quality level or sterilization status:
  • Green: VOC air quality is excellent (1-40)
  • Yellow: VOC air quality is good (41-60)
  • Orange: VOC air quality is moderate (61-80)
  • Red: VOC air quality is poor (≥81)
  • Blue breathing light: Sterilizing

Middle Function Key Area

  • Warm Air Key: Controls the on/off of the warm air function. Long press to cycle through high mode, low mode, and constant temperature mode.
  • Ventilation Key: Controls the on/off of the ventilation function. Long press to cycle between high mode and low mode.
  • Fan Key: Controls the on/off of the fan function. Long press to cycle between high mode and low mode.
  • Air Direction Key: Controls the oscillation and fixed angle of the air guide louver. Only effective when warm air or fan function is enabled.
  • High Mode Indicators: When a function is in high mode, the triangular indicator above the corresponding key illuminates.

Bottom Auxiliary Function Area

  • Lighting Key: Controls the on/off of the lighting function. Long press to adjust lighting brightness.
  • Sterilization Key: Controls the on/off of the sterilization function.
  • Stop Key: Turns off all functions except lighting. Long press to set the delayed shutdown duration.

5.2 Remote Control Basic Function Operations

5.2.1 Warm Air Function

The warm air function is the core function of the bathroom heater, providing warm air during bathing.

  • Short press the Warm Air key: Turns on the warm air function, defaulting to the last used mode (factory default is constant temperature mode). When warm air is enabled, the warm air key illuminates fully, and the main unit’s lift sliding cover light panel opens.
  • Long press the Warm Air key for 2 seconds: Cycles between high mode, low mode, and constant temperature mode.
  • Warm Air High Mode: Maximum power, fastest heating speed, suitable for rapid temperature increase.
  • Warm Air Low Mode: Lower power, quiet operation, suitable for maintaining temperature.
  • Constant Temperature Mode: Automatically adjusts power to maintain the bathroom temperature within the set target temperature range.
  • Automatic Stop: If the warm air function runs for more than 2 hours, it will automatically stop to prevent overheating.
  • Delayed Shutdown: When the warm air function is turned off, it will delay shutdown by 20 seconds for heat dissipation. However, if warm air is turned off within 5 seconds of being turned on, it is determined to be an accidental touch and shuts down immediately without delay.

5.2.2 Constant Temperature Mode

Constant temperature mode automatically adjusts warm air power to maintain the bathroom temperature within the set target temperature range, providing a comfortable bathing environment.

  • Entering Constant Temperature Mode: Long press the Warm Air key for 2 seconds to switch to constant temperature mode. The “Constant Temp” indicator lights up, and the display shows the current indoor temperature.
  • Setting the Target Temperature:

1. Press the “+” or “-” key. The “Target” indicator lights up, the display shows the current target temperature, and the digit flashes (on for 0.4 s, off for 0.2 s).

2. Press “+” to increase the target temperature, press “-” to decrease it, in 1°C increments.

3. Target temperature adjustment range: 25°C-35°C.

4. When the digit reaches the maximum of 35°C, pressing “+” again keeps the digit at 35 and emits a “beep-beep-” tone.

5. When the digit reaches the minimum of 25°C, pressing “-” again keeps the digit at 25 and emits a “beep-beep-” tone.

  • Confirming the Target Temperature: After 10 seconds of no operation, the digit stops flashing, displays the set temperature steadily for 1 second, then the “Target” indicator turns off, the display shows the current indoor temperature, and constant temperature mode begins operation.
  • Operating Principle: In constant temperature mode, the unit operates at maximum power during heating, then switches to minimum power upon reaching the target temperature.

5.2.3 Ventilation Function

The ventilation function is used to expel stale air from the bathroom, keeping the air fresh.

  • Short press the Ventilation key: Turns on the ventilation function, defaulting to the last used mode (factory default is high mode). When ventilation is enabled, the ventilation key illuminates fully, and the main unit’s lift sliding cover light panel opens.
  • Long press the Ventilation key for 2 seconds: Cycles between high and low modes.
  • Ventilation High Mode: Maximum airflow, suitable for rapid ventilation when the bathroom has odors.
  • Ventilation Low Mode: Lower airflow, quiet operation, suitable for long-term ventilation in bathrooms without windows.
  • Automatic Stop: The ventilation function automatically stops after 2 hours of operation.
  • Odor-Sensing Ventilation: After network connection, enable the odor-sensing function in the APP. When the VOC index reaches the sensitivity threshold, within the odor-sensing time period (default 7:00-23:00), and at least 15 minutes have passed since the last ventilation shutdown, ventilation high mode will automatically turn on.

5.2.4 Fan Function

The fan function provides cool air in summer or dries the body after bathing.

  • Short press the Fan key: Turns on the fan function, defaulting to the last used mode (factory default is high mode). When the fan is enabled, the fan key illuminates fully, and the main unit’s lift sliding cover light panel opens.
  • Long press the Fan key for 2 seconds: Cycles between high and low modes.
  • Fan High Mode: Maximum airflow, suitable for summer use.
  • Fan Low Mode: Lower airflow, quiet operation.
  • Automatic Stop: The fan function automatically stops after 2 hours of operation.

5.2.5 Air Direction Function

The air direction function adjusts the angle of the air guide louver to control the direction of warm air or fan airflow.

  • Usage Condition: Only effective when the warm air or fan function is enabled.
  • Short press the Air Direction key: Toggles between louver oscillation and fixed angle states.
  • Oscillation Mode: The louver oscillates cyclically between 60°-90°, distributing air evenly throughout the bathroom. When oscillation is enabled, the Air Direction key illuminates fully.
  • Directional Mode: The louver is fixed at the current angle. When directional airflow is enabled, the Air Direction key illuminates at half brightness.
  • Note: The louver cannot be stopped at a fixed angle within 0°-60°.
  • During Sterilization: The louver is forced to oscillate and is not controlled by the air direction mode.

5.2.6 Lighting Function

The lighting function provides bathroom illumination.

  • Short press the Lighting key: Turns the lighting function on or off, at the brightness set on the remote control or APP. When lighting is enabled, the Lighting key illuminates fully.
  • Long press the Lighting key for 2 seconds: Adjusts lighting brightness. The remote control adjustment range has three levels: 20%, 60%, and 100%. Release the key to confirm the setting.
  • Light Tap on Remote Panel:
  • During non-smart nightlight hours: toggles the lighting function on/off, at the brightness set on the remote control or APP.
  • During smart nightlight hours: toggles the smart nightlight function on/off at 1% brightness. When the nightlight is enabled, the Lighting key illuminates at half brightness.
  • APP Adjustment: The lighting brightness can be adjusted more precisely in the APP, range 1-100%, in 1% increments.
  • Color Temperature: After first power-on or factory reset, the default lighting color temperature is 6000K (cool white). The color temperature can be adjusted in the APP, range 2800K-6000K.

5.2.7 Smart Nightlight Function

The smart nightlight function provides dim illumination at night to avoid harsh glare.

  • Activation Conditions: Enable the smart nightlight function in the APP and set the smart nightlight time period (default 21:00 – 06:00 the next day).
  • Activation Method: During the smart nightlight time period, lightly tap the remote control panel to turn on the smart nightlight at 1% brightness.
  • Deactivation Method: Lightly tap the remote control panel again, or short press the Lighting key to turn on normal lighting — the nightlight function automatically turns off.
  • Automatic Shutdown: The smart nightlight automatically turns off after 15 minutes by default.

5.2.8 Sterilization Function

The sterilization function kills bacteria in the bathroom air, removes odors, and maintains bathroom hygiene.

  • Short press the Sterilization key: Starts the sterilization automatic program. The total program duration is 60 minutes: Ventilation 5 minutes → Drying 25 minutes → Fan with ions 30 minutes.
  • During Sterilization:
  • The Sterilization key illuminates fully.
  • The light bar on the screen changes to a blue breathing light (gradually brightening for 1 s, on for 0.2 s, gradually dimming for 1.4 s, off for 0.4 s, cycling).
  • The main unit’s sterilization indicator illuminates.
  • During the fan or warm air phases, the louver is forced to oscillate automatically and is not controlled by the air direction mode.
  • Stopping Sterilization: Short press the “Sterilization” or “Stop” key during operation to turn off the sterilization function.
  • Automatic Stop: The sterilization program automatically stops after completion. The Sterilization key illuminates at half brightness, the light bar reverts to VOC air quality indication, and the main unit’s sterilization indicator turns off.
  • Mutual Exclusion: The sterilization function is mutually exclusive with the warm air, ventilation, and fan functions. Enabling sterilization will turn off the other functions.

5.2.9 Stop Function

The stop function turns off currently running functions.

  • Short press the Stop key: Turns off all functions except lighting. Functions including warm air will delay shutdown by 20 seconds (for heat dissipation). However, if warm air is turned off within 5 seconds of being turned on, it is determined to be an accidental touch and shuts down immediately.
  • Long press the Stop key for 2 seconds: Enters delay duration setting mode:
  • The “+”, “-“, “Min”, delay icon, and Stop key illuminate. The “°C” icon turns off. The display shows the current delay duration, and the digit flashes.
  • Press “+” or “-” to adjust the delay duration in 5-minute increments. Adjustment range: 5-60 minutes. Initial value: 15 minutes.
  • After 10 seconds of no operation, the digit stops flashing, displays the set duration steadily for 1 second, then “+”, “-“, and “Min” turn off. The display shows the current temperature, and the “°C” icon illuminates.
  • Delayed Shutdown: After setting the delay duration, all functions except lighting are turned off after the delay. During the delay countdown, the delay icon, Stop key, and the delayed-shutdown function keys illuminate fully. After the delay ends, the delay icon turns off, and the Stop key and delayed-shutdown function keys illuminate at half brightness.
  • Clearing the Delay: During the delay state, pressing any other function key or short pressing the Stop key clears the current delay setting.
  • APP Settings: The delay duration can be set in the APP, as well as whether the Stop key turns off the lighting function.

5.3 Remote Control Advanced Function Operations

5.3.1 Wi-Fi Connection Function

The Wi-Fi connection function connects the remote control to the home network, enabling APP remote control and smart automation.

  • Enabling Wi-Fi: Simultaneously long press the 【Air Direction】 and 【Ventilation】 keys for 7 seconds. Upon hearing a “beep~” (long tone) of 500 ms, the remote control Wi-Fi icon illuminates, and the main unit panel Wi-Fi indicator lights up blue for 2 seconds.
  • Disabling Wi-Fi: Simultaneously long press the 【Air Direction】 and 【Fan】 keys for 7 seconds. Upon hearing a “beep~” (long tone) of 500 ms, the remote control Wi-Fi icon and the main unit panel Wi-Fi indicator turn off.
  • Pending Network Configuration State: The remote control Wi-Fi icon flashes, and the main unit panel Wi-Fi indicator flashes orange (on for 800 ms, off for 400 ms). If not connected to the network within 30 minutes, the remote control Wi-Fi icon and main unit panel Wi-Fi indicator automatically turn off.
  • Connecting State: The remote control Wi-Fi icon flashes, and the main unit panel Wi-Fi indicator flashes blue (on for 400 ms, off for 200 ms).
  • Fault State (Network Disconnected): The remote control Wi-Fi icon flashes, and the main unit panel Wi-Fi indicator stays solid orange.
  • Online State: The remote control Wi-Fi icon stays solid, and the main unit panel Wi-Fi indicator stays solid blue.
  • Network Reset: Simultaneously long press the 【Lighting】 and 【Ventilation】 keys for 7 seconds. The remote control Wi-Fi icon flashes, and the main unit panel Wi-Fi indicator flashes blue (on for 800 ms, off for 400 ms) 3 times, accompanied by a “beep-beep-beep” tone. Resetting Wi-Fi does not clear Bluetooth pairing.

5.3.2 Bluetooth Connection Function

The Bluetooth connection function enables communication between the remote control and the main unit.

  • Remote Control Powered but Unpaired State: When the remote control is powered on but not yet paired with the main unit, the screen displays 00°C and the light bar shows green. After successful pairing, the current temperature and air quality are displayed.
  • Remote Control Pairing: Simultaneously long press the 【Lighting】 and 【Fan】 keys for 3 seconds. The Bluetooth icon flashes (on for 400 ms, off for 200 ms), entering pairing mode.
  • Pairing Successful: The Bluetooth icon stays solid for 5 seconds then turns off, accompanied by a “beep-” (short tone) of 100 ms.
  • Pairing Failed: The Bluetooth icon turns off, accompanied by a “beep-beep-” (two short tones, 100 ms each / 200 ms interval).
  • Note: During Bluetooth pairing, pressing other keys has no response. If no tone is heard, pairing needs to be repeated.

5.3.3 Factory Reset

The factory reset function restores the remote control to its factory default state.

  • Operation Method: While the remote control is connected, simultaneously long press the 【Lighting】 and 【Stop】 keys for 7 seconds.
  • Reset Successful: The screen returns to standby state, accompanied by a “beep~” (long tone) of 500 ms.
  • Reset Failed: Emits “beep-beep-” (two short tones).
  • State After Reset:
  • The main unit Wi-Fi indicator and the remote control Wi-Fi icon turn off.
  • Remote control is disabled, the remote control indicator turns off, and re-authorization is required.
  • All settings revert to factory defaults.

5.3.4 System Upgrade

The system upgrade function upgrades the firmware of the remote control and main unit, providing new features and performance improvements.

  • Upgrade Method: Initiate the upgrade through the MIJIA APP.
  • Upgrade Process:

1. The APP initiates the upgrade. The remote control screen displays “UP” and begins downloading firmware, accompanied by a “beep-” (short tone) of 100 ms.

2. After download completes, installation proceeds automatically. The screen continues to display “UP”.

  • Upgrade Successful: The screen returns to standby state, accompanied by a “beep-” (short tone) of 100 ms.
  • Upgrade Failed: The screen returns to standby state, accompanied by a “beep-beep-” (two short tones).

5.3.5 Smart Human-Sensing Function

The smart human-sensing function uses a radar sensor to detect human presence, enabling automatic lighting, automatic ventilation, and automatic shutdown.

  • Activation Method: Enable the smart human-sensing function in the MIJIA APP and configure the relevant parameters.
  • Sensitivity Settings: High, medium, and low — three levels. Default: medium sensitivity.
  • Sensing Distance Settings: Near, medium, and far — three levels. Default: medium distance (near: 1 m, medium: 1.5 m, far: 2 m).

Human-Sensing Lighting Function

  • Trigger Conditions: Within the human-sensing lighting time period, when the radar detects human presence AND the photosensitive sensor detects darkness (indoor illumination < 100 lux).
  • Operating Principle: When trigger conditions are met, the bathroom lighting automatically turns on. When the radar detects no human presence for the duration set by the sensitivity level (high sensitivity – 20 seconds, medium sensitivity – 20 seconds, low sensitivity – 40 seconds), the bathroom lighting automatically turns off.
  • Human-Sensing Nightlight: When the smart nightlight switch is enabled AND both the human-sensing lighting time period and the smart nightlight time period are simultaneously met, entering the bathroom automatically activates the low-brightness (1%) nightlight.
  • Manual Intervention:
  • During the human-sensing lighting time period, after manually turning off the lighting, the human-sensing lighting function becomes ineffective upon detecting human presence, and is reactivated after detecting no human presence.
  • During the human-sensing lighting time period, when lighting is manually turned on, lighting can be turned off either via human sensing or manually.
  • During the human-sensing lighting time period, when lighting is already on and human presence is detected, lighting remains on.

Human-Sensing Ventilation Function

  • Trigger Conditions: Enable the human-sensing ventilation function in the APP. Within the set time period, when human presence is detected for a duration meeting the user-set value (default 1 minute, adjustable 0-60 minutes).
  • Operating Principle: When trigger conditions are met, the ventilation function turns on. When no human presence is detected for a duration meeting the user-set value (default 5 minutes, adjustable 0-60 minutes), the ventilation function turns off.
  • Mode Settings: The mode for human-sensing ventilation activation is determined by sensitivity settings:
  • High Sensitivity: Faster response, may increase false triggers. Ventilation high mode.
  • Medium Sensitivity: Meets daily scenario requirements. Ventilation low mode.
  • Low Sensitivity: Slower response, recommended for complex environments, reduces false triggers. Ventilation low mode.
  • Manual Intervention: After the radar automatically triggers ventilation, if the user manually turns off ventilation, the human-sensing ventilation function remains ineffective upon detecting human presence, and is reactivated 5 minutes after no human presence is detected.

Human-Sensing Shutdown Function

  • Activation Method: Enable the human-sensing shutdown function in the APP.
  • Operating Principle: After enabling this function, when no human presence is detected for 10 minutes (adjustable 0-60 minutes) AND no automation program is running (such as smart defogging, drying, sterilization functions), automatically turns off already-enabled functions (warm air / lighting / fan) for energy savings.
  • Priority: The priority of the human-sensing shutdown function is lower than that of automation programs (such as smart defogging, drying, sterilization).
  • Relationship with Other Functions:
  • If human-sensing lighting and human-sensing shutdown are both enabled, when lighting is turned off via human sensing, the no-presence judgment duration from the human-sensing lighting sensitivity setting takes precedence.
  • If human-sensing lighting is not enabled, and only human-sensing shutdown is enabled, when lighting is turned off via human sensing, the no-presence judgment duration from the human-sensing shutdown setting takes precedence.
  • If human-sensing shutdown and delayed lighting are both enabled, the delayed lighting function takes priority.
  • If human-sensing shutdown and delayed shutdown are both enabled, the delayed shutdown function takes priority.

5.4 Mutual Exclusion Relationships Between Functions

To ensure safe equipment operation, certain remote control functions are mutually exclusive and cannot be enabled simultaneously:

Functions Exclusion Rule
Warm Air and Fan Share the same air duct; cannot be turned on simultaneously.
Sterilization and Warm Air, Ventilation, Fan When sterilization is enabled, the other functions are turned off.
Defogging/Drying and Other Functions After defogging or drying is enabled, other functions turn off; when other function keys are pressed, defogging or drying turns off.
Lighting and Nightlight When the lighting function is on, the nightlight automatically turns off; when the nightlight is on, the lighting function automatically turns off.

5.5 Functions That Can Be Enabled Simultaneously

The following functions can be enabled at the same time:

Function Combination Description
Ventilation and Warm Air/Fan Ventilation can be enabled simultaneously with warm air or fan.
Lighting and All Other Functions The lighting function can be enabled simultaneously with any other function.

The remote control pairing test is the first and most important step in remote control factory testing. Only a successfully paired remote control can communicate properly with the main unit and implement various functions.

Part 3: Pairing Test, Coordinate Calibration, Action Settings, Flow Recording, and Function Verification

6.1 Pre-Pairing Preparation

Before conducting the pairing test, please complete the following preparations:

Bathroom Heater Main Unit Preparation

  • The bathroom heater main unit is correctly installed and powered on normally.
  • The main unit indicator light is on, and the unit is in standby mode.
  • The distance between the main unit and the remote control is ≤ 1 meter, with no obstructions.
  • Keep away from strong electromagnetic interference sources such as routers and metal objects.

Remote Control Preparation

  • The remote control is correctly installed and powered on normally.
  • The remote control buttons are responsive, with no sticking.
  • The remote control screen displays normally.

Test Equipment Preparation

  • The dual-station fixture robotic arm is correctly installed and debugged.
  • Both the left and right control software programs have been successfully started and serial connections with the robotic arm have been established.
  • The camera is turned on, the image is clear, and the remote control panel can be fully displayed.
  • The remote control is fixed on the fixture, positioned accurately, without any wobble.

Software Preparation

  • Software coordinate calibration has been completed (see Section 7 for coordinate calibration method).
  • Action parameters have been set to default values.

6.2 Pairing Test Three Steps (Core)

The pairing test for the Mijia Smart Bathroom Heater P1 remote control is divided into three core steps: enter pairing mode, pairing success check, and function verification.

6.2.1 Step 1: Enter Pairing Mode (Press and Hold the Combination Key for 3 Seconds)

Pairing mode is entered by simultaneously pressing and holding the “Light” and “Fan” keys for 3 seconds.

Software Setup Method:

1. In the left software, check the “Force Move” checkbox in the manual control area.

2. Click the “Up/Down/Left/Right” buttons to move the robotic arm to the position above the “Light” key.

3. Record the current X/Y coordinates (e.g., X33 Y137).

4. Continue moving the robotic arm to the position above the “Fan” key.

5. Record the current X/Y coordinates (e.g., X189 Y85).

6. In the action parameter area, set:

  • Hold Time: 3000ms (3 seconds)
  • Downward Travel: 7mm (ensure both keys can be pressed)
  • Upward Travel: 2mm
  • Delay After Success Before Click: 500ms

7. In the step editing area, add two “Move Arm” steps:

  • Step 1: Move to the Light key coordinates (X33 Y137)
  • Step 2: Move to the Fan key coordinates (X189 Y85)

8. Add a “Click” step, set to click both positions simultaneously.

9. Click the “Test” button; the robotic arm will press and hold the “Light” and “Fan” keys simultaneously for 3 seconds, and the remote control will enter pairing mode.

Expected Result: The Bluetooth icon on the remote control screen begins to blink (on for 400ms, off for 200ms).

6.2.2 Step 2: Pairing Success Check

After entering pairing mode, the remote control will automatically search for the nearby bathroom heater main unit and perform pairing.

Pairing Success Criteria:

  • The main unit emits three “beep-beep-beep” sounds.
  • The indicator light on the main unit panel flashes 3 times.
  • The Bluetooth icon on the remote control screen remains lit for 5 seconds then turns off.
  • The remote control screen displays the current indoor temperature and no longer displays “00”.

Software Automatic Check Method:

1. Add an “Image Recognition” step in the software, set to recognize the main unit indicator light flashing 3 times.

2. Add a “Sound Recognition” step, set to recognize three beeps.

3. If both conditions are met, the pairing is judged as successful, and the process continues to the next step.

4. If the pairing success signal is not detected within 30 seconds, the pairing is judged as failed, and the software automatically alarms and stops.

6.2.3 Step 3: Function Verification (Press the Warm Air Key for 1 Second)

After successful pairing, it is necessary to verify that the remote control can normally control the main unit. The most common verification method is to press the warm air key and check whether the main unit responds.

Software Setup Method:

1. In the action parameter area, set:

  • Hold Time: 1000ms (1 second)
  • Downward Travel: 6mm
  • Upward Travel: 1mm
  • Delay After Success Before Click: 1000ms

2. Add a “Move Arm” step to move to the warm air key coordinates (e.g., X85 Y85).

3. Add a “Click” step.

4. Add an “Image Recognition” step, set to recognize the main unit warm air function startup phenomenon (e.g., main unit air outlet opens, indicator light turns on, etc.).

If the warm air function startup is recognized, the function verification is judged as passed, and the pairing test is complete.

If the warm air function startup is not recognized, the function verification is judged as failed, and the software automatically alarms and stops.

6.3 Complete Pairing Test Flow

The following is the complete pairing test flow, which can be directly recorded in the software:

1. The robotic arm moves to the home position.

2. Move to the “Light + Fan” combination key position.

3. Press and hold both keys simultaneously for 3 seconds to enter pairing mode.

4. Wait 30 seconds to detect the pairing success signal (light flashes 3 times + 3 beeps).

5. If pairing fails, alarm and stop.

6. If pairing is successful, move to the warm air key position.

7. Shortly press the warm air key for 1 second.

8. Wait 1 second to detect whether the warm air function is activated.

9. If function verification fails, alarm and stop.

10. If function verification passes, move to the stop key position.

11. Shortly press the stop key to turn off the warm air function.

12. The robotic arm returns to the home position.

13. Pairing test complete; record the test result.

6.4 Pairing Fault Troubleshooting

During the pairing test process, various faults may be encountered. The following lists common pairing faults and troubleshooting methods:

6.4.1 No Pairing Response When Pressing and Holding the Combination Key

Possible Causes:

  • The robotic arm press position is offset, failing to press both keys simultaneously.
  • The press force is insufficient; the keys are not effectively pressed.
  • The hold time is less than 3 seconds.
  • The remote control battery is dead or has poor contact.
  • The remote control keys are damaged.
  • The main unit is not powered on or is in a fault state.

Troubleshooting Methods:

  • Fine-tune coordinates: Fine-tune the robotic arm’s X/Y coordinates to ensure the press head is simultaneously aligned with the centers of both keys.
  • Increase downward travel: Increase the downward travel to 7-8mm to increase press force.
  • Extend hold time: Set the hold time to 3500ms to ensure sufficient hold duration.
  • Check remote control power: Check whether the remote control power wiring is secure and the voltage is normal.
  • Manual test: Manually press and hold the “Light” and “Fan” keys simultaneously for 3 seconds to see whether pairing mode can be entered. If manual activation also fails, the remote control or main unit has a problem.
  • Check the main unit: Check whether the main unit is powered on normally and in standby mode.

6.4.2 Pairing Mode Entered but No Light Flash or Beep

Possible Causes:

  • The distance between the remote control and the main unit is too far or there are obstructions.
  • Strong electromagnetic interference in the surrounding area.
  • The main unit has already been paired with another remote control.
  • The main unit Bluetooth module is faulty.
  • The remote control Bluetooth module is faulty.

Troubleshooting Methods:

  • Shorten distance: Shorten the distance between the remote control and the main unit to within 50cm, ensuring no obstructions.
  • Eliminate interference: Turn off strong electromagnetic interference sources such as nearby routers and microwave ovens.
  • Clear main unit pairing: Power off the main unit for 10 seconds and then power it back on to clear previous pairing information.
  • Test with a replacement remote control: Use a known-good remote control for the pairing test. If pairing succeeds, the original remote control’s Bluetooth module is faulty.
  • Test with a replacement main unit: Use a known-good main unit for the pairing test. If pairing succeeds, the original main unit’s Bluetooth module is faulty.

6.4.3 Pairing Successful but Warm Air Key Does Not Respond

Possible Causes:

  • The robotic arm press position is offset, failing to press the warm air key.
  • The press force is insufficient; the key is not effectively pressed.
  • The warm air key is damaged.
  • The main unit warm air function is faulty.
  • An anomaly occurred during pairing; communication is unstable.

Troubleshooting Methods:

  • Fine-tune coordinates: Fine-tune the robotic arm’s X/Y coordinates to ensure the press head is aligned with the center of the warm air key.
  • Increase downward travel: Increase the downward travel to 7mm to increase press force.
  • Manual test: Manually press the warm air key to check whether the main unit responds. If there is no response manually, the warm air key or main unit has a problem.
  • Re-pair: Power off both the main unit and remote control for 10 seconds, then power them back on and re-run the pairing test.
  • Test other keys: Test whether other keys such as Light and Ventilation respond. If other keys also do not respond, the pairing failed or there is a communication fault.

Part 7: Software Coordinate Calibration

Coordinate calibration is the key step for the software to accurately control the robotic arm to press keys. If coordinate calibration is inaccurate, the robotic arm will press incorrect positions, causing test failure.

7.1 Root Cause Analysis of Coordinate Calibration Errors

During coordinate calibration or testing, the most common error is “Recognition result is not a coordinate parameter” or “Invalid coordinate.” The root cause of this error is that the software has not correctly established the mapping relationship between image pixel coordinates and robotic arm physical coordinates.

Specific causes include:

  • Image area coordinates not obtained.
  • Robotic arm travel coordinates not obtained.
  • The “Fixed Camera and Screen Projection Must Be Selected” checkbox is not checked.
  • The computer display resolution is not 1920×1080.
  • Coordinate values are negative or empty.
  • The top-left values of the image area coordinates are greater than the bottom-right values.
  • The top-left values of the robotic arm coordinates are greater than the bottom-right values.
  • Camera image drift.

7.2 Three-Step Calibration Method (Required, Resolves All Coordinate Errors)

This system uses the “Three-Step Calibration Method” for coordinate calibration. As long as these three steps are strictly followed, all coordinate-related errors can be resolved.

7.2.1 Step 1: Obtain Image Area Coordinates

Image area coordinates refer to the pixel coordinate range of the remote control panel in the camera image.

Operating Method:

1. Ensure the camera is turned on and the image preview area clearly displays the remote control panel.

2. Check the “Fixed Camera and Screen Projection Must Be Selected” checkbox (must be checked!).

3. Click the “Get Image Area Coordinates” button in the coordinate calibration area.

4. The mouse pointer will change to a crosshair. In the image preview area, starting from the top-left corner of the remote control panel, press and hold the left mouse button and drag to the bottom-right corner of the remote control panel, completely framing the entire remote control panel.

5. Release the left mouse button; the software will automatically fill in the pixel coordinate values for “Top-Left X/Y” and “Bottom-Right X/Y”.

  • Example: Top-Left X108 Y313, Bottom-Right X435 Y646.

6. Check the coordinate values:

  • Ensure Top-Left X < Bottom-Right X, and Top-Left Y < Bottom-Right Y.
  • Ensure all coordinate values are positive and not empty.
  • Ensure the framed area completely includes all keys of the remote control.

7.2.2 Step 2: Obtain Robotic Arm Position Coordinates

Robotic arm position coordinates refer to the physical coordinate range that the robotic arm can reach at the top-left and bottom-right corners of the remote control panel.

Operating Method:

1. Check the “Force Move” checkbox in the manual control area.

2. Click the “Get Device Position Coordinates” button in the coordinate calibration area.

3. A prompt box will pop up, stating “Please move the robotic arm to the top-left corner, then click Confirm.”

4. Use the “Up/Down/Left/Right” and “Up 1mm/Down 1mm” buttons in the manual control area to move the robotic arm press head to the top-left corner position of the remote control panel (i.e., the physical position corresponding to the top-left corner of the image area).

5. Click the “Confirm” button in the prompt box.

6. Another prompt box will pop up, stating “Please move the robotic arm to the bottom-right corner, then click Confirm.”

7. Continue using the manual control buttons to move the robotic arm press head to the bottom-right corner position of the remote control panel (i.e., the physical position corresponding to the bottom-right corner of the image area).

8. Click the “Confirm” button in the prompt box.

9. The software will automatically fill in the robotic arm’s “Top-Left X/Y” and “Bottom-Right X/Y” physical coordinate values.

  • Example: Top-Left X12 Y16, Bottom-Right X97 Y112.

10. Check the coordinate values:

  • Ensure Top-Left X < Bottom-Right X, and Top-Left Y < Bottom-Right Y.
  • Ensure all coordinate values are positive and not empty.

7.2.3 Step 3: Set Effective Travel

Effective travel refers to the maximum movement range of the robotic arm.

Operating Method:

1. In the “Enter Device Effective Travel (mm) X/Y” input fields, enter the effective travel of the robotic arm.

  • X-axis: 300mm
  • Y-axis: 300mm

2. Click the “Test” button; the software will perform coordinate mapping calculation.

3. If there is no error, the coordinate calibration is successful.

4. If there is an error, check whether the coordinate values from the previous two steps are correct, and re-calibrate.

7.3 Post-Calibration Verification

After coordinate calibration is completed, verification must be performed to ensure the robotic arm can accurately press the keys.

Verification Method:

1. In the manual control area, check the “Force Move” checkbox.

2. In the action parameter area, set:

  • Hold Time: 100ms
  • Downward Travel: 6mm
  • Upward Travel: 1mm

3. In the image preview area, click the center position of the Light key.

4. Click the “Test” button; the robotic arm should move to the position above the Light key, then descend to press.

5. Observe whether the robotic arm press position accurately lands on the center of the Light key.

6. If there is position deviation, fine-tune the “Recognition Click Position Deviation X/Y” parameter for compensation:

  • If the press position is too far left, increase the X deviation value.
  • If the press position is too far right, decrease the X deviation value.
  • If the press position is too high, increase the Y deviation value.
  • If the press position is too low, decrease the Y deviation value.

7. Repeat the test until the press position is accurate.

8. Use the same method to test other keys, ensuring all key press positions are accurate.

7.4 Coordinate Calibration Precautions

  • Fix the camera: After calibration is completed, absolutely do not move the camera position and angle; otherwise, re-calibration is required.
  • Fix the remote control: After calibration is completed, absolutely do not move the remote control position in the fixture; otherwise, re-calibration is required.
  • Fix the resolution: The computer display resolution must be maintained at 1920×1080; otherwise, re-calibration is required.
  • Check the fixed camera option: The “Fixed Camera and Screen Projection Must Be Selected” checkbox must always be checked to prevent image drift.
  • Regular calibration: It is recommended to perform coordinate calibration once a week to ensure test accuracy.
  • Replacing fixture or remote control model: If the fixture or remote control model is changed, coordinate calibration must be re-performed.

Part 8: Single Key Action Settings

Single key action settings refer to setting individual press action parameters for each key. This is the foundation for building a complete test flow.

8.1 Solving the “Program Reaches Position but Does Not Press Down” Problem

When setting single key actions, the most common problem is “program reaches position but does not press down,” meaning the robotic arm moves to the position above the key, but the Z-axis does not descend to press.

Possible Causes:

  • The Z-axis downward travel is not set or set to 0.
  • The hold time is set too short (less than 10ms).
  • The “Force Move” checkbox is not checked.
  • The Z-axis motor cable is plugged in reversed or loose.
  • The Z-axis guide rail is blocked by foreign objects.
  • Coordinate offset; the robotic arm has not moved to the correct position.
  • The software has not correctly sent the G-code command.

Solutions:

  • Check downward travel: Ensure the “Downward Travel” parameter is set to 6-8mm, not 0.
  • Check hold time: Ensure the “Hold Time” parameter is set to 60-100ms, not 0.
  • Check force move: Ensure the “Force Move” checkbox in the manual control area is checked.
  • Check motor cable: Confirm the Z-axis motor cable is plugged in securely and not reversed.
  • Check guide rail: Manually move the Z-axis to check for obstructions; clean any foreign objects promptly.
  • Re-calibrate coordinates: If the robotic arm position is offset, re-perform coordinate calibration.
  • Use serial port debugging tool: Open the serial port debugging tool to monitor whether the software has sent the Z-axis descent G-code command. If not sent, restart the software; if sent but the robotic arm does not act, check the control board and motor.

8.2 Standard Procedure for Single Key Settings (Using the Light Key as an Example)

The following is the standard procedure for setting a single key action, using the Light key as an example:

8.2.1 Step 1: Set Target Coordinates

1. Ensure coordinate calibration has been completed and verified.

2. In the image preview area, click the center position of the Light key.

3. The software will automatically obtain the pixel coordinates of that position and convert them to the robotic arm’s physical coordinates, displayed in the coordinate display area.

4. Alternatively, manually enter the physical coordinates of the Light key (e.g., X33 Y137).

5. Enter “Light Key” in the “Remark” input field for easy identification.

6. Click the “Test” button; the robotic arm will move to that coordinate position.

7. Observe whether the robotic arm press head is aligned with the center of the Light key. If there is deviation, fine-tune the X/Y coordinate values.

8.2.2 Step 2: Set Action Parameters

In the action parameter area, set the following standard parameters (applicable to all light-touch keys of the Mijia Smart Bathroom Heater P1 remote control):

Parameter Name Standard Value Description
Hold Time 60ms Standard press time for light-touch keys
Downward Travel 6mm Ensures the key is effectively pressed without damaging the key
Upward Travel 1mm Z-axis ascent height after pressing, to avoid affecting the next press
Delay After Success Before Click 200ms Prevents false triggering caused by consecutive presses
Recognition Click Position Deviation X/Y 0mm Fine-tune if there is deviation
Click Random Positive/Negative Deviation X/Y ±0.5mm Simulates the randomness of a human finger press
Number of Actions 1 time Press each key once
Action Interval Time 150ms Interval time between multiple presses
Delay Before Next Step After Success 1000ms Waiting time for remote control response

8.2.3 Step 3: Test Verification

1. Check the “Force Move” checkbox in the manual control area.

2. Click the “Test” button; the robotic arm will execute the complete key action: move to above the key → descend to press → ascend to reset.

3. Observe whether the key is effectively pressed and whether the remote control has a corresponding response (e.g., light turns on).

4. If the key is not pressed, increase the downward travel to 7mm.

5. If the remote control does not respond, extend the “Delay Before Next Step After Success” time to 1500ms.

6. Repeat the test 3-5 times to ensure the key function is successfully triggered every time.

8.2.4 Step 4: Insert Step

1. Confirm the single key action settings are correct and the test has passed.

2. Click the “Insert Step” button to add this key action to the test flow.

3. The software will add a new step to the step list, displaying the remark information and parameters.

8.3 Special Key Action Settings

In addition to ordinary single key actions, some special keys require different action parameters.

8.3.1 Long Press Keys (e.g., Mode Switching)

For keys that require a long press to trigger functions (e.g., long press the warm air key to switch modes), a longer hold time needs to be set.

Parameter Settings:

  • Hold Time: 2000ms (2 seconds)
  • Downward Travel: 7mm
  • All other parameters remain at standard values.

8.3.2 Combination Keys (e.g., Pairing)

For combination keys that require two or more keys to be pressed simultaneously to trigger functions (e.g., pairing requires pressing Light + Fan simultaneously), simultaneous clicking of multiple positions needs to be set.

Setup Method:

1. Add multiple “Move Arm” steps, moving to the coordinate position of each key respectively.

2. Add a “Click” step, set to click all positions simultaneously.

3. Set the hold time to 3000ms (3 seconds).

4. Set the downward travel to 7mm to ensure all keys can be pressed.

8.3.3 Brightness Adjustment (Long Press the Light Key)

Long pressing the light key can adjust the lighting brightness, requiring a continuous long press action.

Setup Method:

1. Set the hold time to 2000ms (2 seconds).

2. Set the downward travel to 6mm.

3. Add a loop step, looping 3 times, to achieve three-level brightness adjustment.

8.4 Full Key Parameter Reference Table

The following is the standard parameter reference table for all keys of the Mijia Smart Bathroom Heater P1 remote control:

Key Name X Coordinate (Example) Y Coordinate (Example) Hold Time Downward Travel Remarks
Light 33 137 60ms 6mm Short press for on/off, long press for brightness adjustment
Warm Air 85 85 60ms 6mm Short press for on/off, long press for mode switching
Ventilation 137 85 60ms 6mm Short press for on/off, long press for level switching
Fan 189 85 60ms 6mm Short press for on/off, long press for level switching
Air Direction 241 85 60ms 6mm Only effective when warm air/fan is on
Sterilization 137 137 60ms 6mm Short press for on/off
Stop 189 137 60ms 6mm Short press for stop, long press for delay setting
“+” 241 43 60ms 6mm Adjust temperature/duration
“-“ 33 43 60ms 6mm Adjust temperature/duration

Note: The X/Y coordinates in the table are example values. Actual coordinate values must be set according to your equipment calibration results.

Part 9: Multi-Key Flow Recording and Looping

After single key action settings are completed, these individual key actions need to be combined into a complete test flow according to the test sequence, and loop operation should be set to achieve automated testing.

9.1 Full-Function Test Flow Recording

The full-function test flow refers to a complete flow that tests all key functions of the remote control, suitable for full function inspection before the remote control leaves the factory.

9.1.1 Test Flow Design Principles

  • Comprehensive coverage: Test all functions of all keys, including short press, long press, and combination keys.
  • Logical reasoning: Test according to the logical order of actual user operation, avoiding test failures caused by mutually exclusive functions.
  • Verifiability: Each test step must have a clear, verifiable result, enabling the software to automatically determine whether the test passed.
  • Fault tolerance: Considering possible delays and misjudgments, set reasonable timeout times and retry mechanisms.
  • Safety: Ensure equipment safety during testing, avoiding damage caused by prolonged operation of certain functions.

9.1.2 Mijia Smart Bathroom Heater P1 Full-Function Test Flow

The following is the full-function test flow designed for the Mijia Smart Bathroom Heater P1 remote control:

Pairing Test

1. Simultaneously press and hold the Light + Fan keys for 3 seconds to enter pairing mode.

2. Detect the pairing success signal (light flashes 3 times + 3 beeps).

3. Shortly press the warm air key for 1 second to verify the warm air function starts.

4. Shortly press the stop key to turn off the warm air function.

Light Function Test

5. Shortly press the light key to verify the light turns on.

6. Long press the light key for 2 seconds to verify brightness adjustment (three-level cycle).

7. Shortly press the light key to verify the light turns off.

Warm Air Function Test

8. Shortly press the warm air key to verify the warm air high-level starts.

9. Long press the warm air key for 2 seconds to switch to warm air low-level, verifying level switching.

10. Long press the warm air key for 2 seconds to switch to constant temperature mode, verifying mode switching.

11. Press the “+” key to set the target temperature to 30°C, verifying temperature adjustment.

12. Press the “-” key to set the target temperature to 25°C, verifying temperature adjustment.

13. Shortly press the stop key to turn off the warm air function.

Ventilation Function Test

14. Shortly press the ventilation key to verify the ventilation high-level starts.

15. Long press the ventilation key for 2 seconds to switch to ventilation low-level, verifying level switching.

16. Shortly press the stop key to turn off the ventilation function.

Fan Function Test

17. Shortly press the fan key to verify the fan high-level starts.

18. Long press the fan key for 2 seconds to switch to fan low-level, verifying level switching.

19. Shortly press the stop key to turn off the fan function.

Air Direction Function Test

20. Shortly press the warm air key to turn on the warm air function.

21. Shortly press the air direction key to verify the air deflector oscillates.

22. Shortly press the air direction key to verify the air deflector is fixed at a set angle.

23. Shortly press the stop key to turn off the warm air function.

Sterilization Function Test

24. Shortly press the sterilization key to verify the sterilization function starts (blue breathing light).

25. Shortly press the stop key to turn off the sterilization function.

Delayed Shutdown Function Test

26. Shortly press the warm air key to turn on the warm air function.

27. Long press the stop key for 2 seconds to enter the delay setting mode.

28. Press the “+” key to set the delay to 15 minutes.

29. Verify the delay icon is lit.

30. Shortly press the stop key to clear the delay setting and turn off the warm air function.

Test End

31. Shortly press the stop key to turn off all functions.

32. The robotic arm returns to the home position.

33. Record the test results.

9.1.3 Flow Recording Method

1. According to the method in Part 8, set the action parameters for each key in sequence.

2. After each key action test passes, click the “Insert Step” button to add it to the step list.

3. Use the “Move Up” and “Move Down” buttons to adjust the order of steps to match the test flow design.

4. For steps requiring result verification, add “Image Recognition” or “Sound Recognition” steps and set the verification conditions.

5. For steps requiring looping (e.g., three-level brightness adjustment cycle), add a “Loop” step and set the number of loops.

6. After all steps are added, click the “Save Steps” button to save the test flow as a script file, named “Mijia Smart Bathroom Heater P1 Full-Function Test”.

9.2 Durability Test Flow Recording

The durability test flow refers to long-term cyclic press testing of keys to verify the mechanical life and electrical reliability of the keys.

9.2.1 Durability Test Flow Design

The durability test flow is relatively simple, mainly performing cyclic pressing on a single key or multiple keys.

Single Key Durability Test Flow:

1. Move to the target key position.

2. Press the key once.

3. Delay for a certain period.

4. Loop steps 1-3 until the set number of cycles is reached.

Multiple Key Durability Test Flow:

1. Move to the first key position and press once.

2. Delay for a certain period.

3. Move to the second key position and press once.

4. Delay for a certain period.

5. Sequentially press all keys that need testing.

6. Loop steps 1-5 until the set number of cycles is reached.

9.2.2 Durability Test Parameter Settings

Parameter Name Value Description
Hold Time 60ms Consistent with actual use
Downward Travel 6mm —
Upward Travel 2mm —
Action Interval Time 500ms Avoid overheating of keys caused by consecutive presses
Delay Before Next Step After Success 500ms —
Number of Cycles According to test requirements Typically 100,000, 500,000, or 1,000,000 cycles
Cycle Delay Pause 30 seconds every 1,000 cycles Allow keys to dissipate heat

9.3 Loop Settings

Loop settings are used to control the number of run times and the running method of the test flow.

9.3.1 Loop Count Setting

1. In the “Count” input field of the loop control area, enter the required number of loops.

  • Full-function test: generally set to 1 time.
  • Durability test: set according to test requirements, e.g., 100000 times.
  • Infinite loop: set to 999999 times.

2. The “Executed: Count” display box will show the number of loops already executed in real time.

3. The “Looped Count” display box will show the loop count for each step.

9.3.2 Loop Run Control

  • Start: Click the “Start” button to begin running the test flow. The software will execute each step sequentially according to the step list order and loop for the specified number of times.
  • Pause: Click the “Pause” button to pause the running test flow. Clicking the “Pause” button again will resume running.
  • Stop: Click the “Stop” button to immediately stop running the test flow.
  • Pause Each Step: After checking the “Pause Each Step” checkbox, the test flow will pause after each step is executed, waiting for user confirmation before continuing to the next step. This function is mainly used for debugging the test flow.

9.3.3 Loop Run Precautions

  • Check before long runtime: Before conducting long-duration durability tests, ensure all equipment connections are secure, screws are tightened, and guide rails are well lubricated.
  • Heat dissipation: Ensure the equipment operating environment is well ventilated to avoid equipment overheating.
  • Unattended operation: This system supports unattended operation, but it is recommended to periodically check the equipment running status, especially during the first 30 minutes after the test starts.
  • Data backup: Regularly back up test data to prevent data loss.
  • Safety: During equipment operation, it is strictly forbidden to insert hands or other objects into the movement range of the robotic arm.

9.4 Dual-Station Simultaneous Operation

This system supports dual-station simultaneous operation, capable of testing two remote controls at the same time, doubling efficiency.

9.4.1 Dual-Station Operation Setup

1. In the left software, load the “Mijia Smart Bathroom Heater P1 Full-Function Test” script.

2. Set the loop count to 1 time.

3. In the right software, load the same test script.

4. Set the loop count to 1 time.

5. Ensure the remote controls of both stations are correctly fixed in their fixtures.

6. First click the “Start” button of the left software, then click the “Start” button of the right software; both stations will begin testing simultaneously.

9.4.2 Anti-Collision Measures

Although the movement ranges of the two robotic arms do not cross, the following anti-collision measures are recommended to ensure safety:

  • Stagger start times: Stagger the start times of the two software programs by 5-10 seconds to avoid both robotic arms moving simultaneously.
  • Adjust movement speed: Appropriately reduce the movement speed of the robotic arms to improve safety.
  • Set software limits: Set software limits in the software to restrict the movement range of the robotic arms.
  • Real-time monitoring: During testing, monitor the running status of both robotic arms in real time. Stop immediately if any anomaly occurs.

Part 10: Function Verification and Result Determination

Function verification is the core link of automated testing. Only through function verification can it be determined whether the remote control functions are normal.

10.1 Function Verification Methods

This system mainly uses the following two methods for function verification:

10.1.1 Image Recognition Verification

Image recognition verification collects images of the remote control or main unit through the camera, then uses AI algorithms to recognize features in the image and determine whether the function is normal.

Applicable Scenarios:

  • Verifying the on/off status and color changes of indicator lights.
  • Verifying the content and number changes displayed on the screen.
  • Verifying the movement state of the air deflector.
  • Verifying the open/close state of the main unit air outlet.

Implementation Method:

1. After the step requiring verification, add an “Image Recognition” step.

2. Capture an image of the normal function state as the template image.

3. Set the recognition similarity threshold (generally set to 90%).

4. The software will compare the real-time captured image with the template image. If the similarity reaches the threshold, the verification is judged as passed; otherwise, it is judged as failed.

10.1.2 Sound Recognition Verification

Sound recognition verification collects the sound emitted by the device through a microphone, then uses AI algorithms to recognize the characteristics of the sound and determine whether the function is normal.

Applicable Scenarios:

  • Verifying the key prompt tones.
  • Verifying the pairing success beep sound.
  • Verifying the device alarm sound.

Implementation Method:

1. After the step requiring verification, add a “Sound Recognition” step.

2. Record the sound of the normal function state as the template sound.

3. Set the recognition similarity threshold (generally set to 85%).

4. The software will compare the real-time collected sound with the template sound. If the similarity reaches the threshold, the verification is judged as passed; otherwise, it is judged as failed.

10.2 Function Verification Standards

The following are the verification standards for each function of the Mijia Smart Bathroom Heater P1 remote control:

10.2.1 Pairing Function Verification

  • Verification Method: Sound recognition + Image recognition
  • Verification Standards:
  • The main unit emits three “beep-beep-beep” sounds.
  • The indicator light on the main unit panel flashes 3 times.
  • The Bluetooth icon on the remote control screen remains lit for 5 seconds then turns off.
  • The remote control screen displays the current indoor temperature.

10.2.2 Light Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After shortly pressing the light key, the light key on the remote control is fully lit, and the main unit light turns on.
  • After long pressing the light key, the light brightness changes (three-level cycle).
  • After shortly pressing the light key again, the light key on the remote control is half lit, and the main unit light turns off.

10.2.3 Warm Air Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After shortly pressing the warm air key, the warm air key on the remote control is fully lit, the warm air high-level indicator light turns on, the main unit air outlet opens, and warm air blows out.
  • After long pressing the warm air key to switch to low level, the warm air high-level indicator light turns off, and the main unit air output volume decreases.
  • After long pressing the warm air key to switch to constant temperature mode, the “Constant Temperature” indicator light turns on, and the main unit automatically adjusts the outlet air temperature.
  • After pressing the “+/-” key to adjust the target temperature, the screen displays the target temperature and flashes.
  • After shortly pressing the stop key, the warm air key is half lit, and the main unit air outlet closes after a 20-second delay.

10.2.4 Ventilation Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After shortly pressing the ventilation key, the ventilation key on the remote control is fully lit, the ventilation high-level indicator light turns on, and the main unit makes a ventilation sound.
  • After long pressing the ventilation key to switch to low level, the ventilation high-level indicator light turns off, and the main unit ventilation sound becomes quieter.
  • After shortly pressing the stop key, the ventilation key is half lit, and the main unit ventilation stops.

10.2.5 Fan Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After shortly pressing the fan key, the fan key on the remote control is fully lit, the fan high-level indicator light turns on, the main unit air outlet opens, and cool air blows out.
  • After long pressing the fan key to switch to low level, the fan high-level indicator light turns off, and the main unit air output volume decreases.
  • After shortly pressing the stop key, the fan key is half lit, and the main unit air outlet closes.

10.2.6 Air Direction Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After turning on the warm air/fan function, shortly pressing the air direction key causes the air deflector to start oscillating cyclically.
  • Shortly pressing the air direction key again fixes the air deflector at the current angle.
  • After turning off the warm air/fan function, the air direction key does not respond.

10.2.7 Sterilization Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After shortly pressing the sterilization key, the sterilization key on the remote control is fully lit, the screen light bar changes to a blue breathing light, and the main unit sterilization indicator light turns on.
  • After shortly pressing the stop key, the sterilization key is half lit, the screen light bar changes back to the VOC air quality prompt, and the main unit sterilization indicator light turns off.

10.2.8 Delayed Shutdown Function Verification

  • Verification Method: Image recognition
  • Verification Standards:
  • After turning on the warm air function, long pressing the stop key enters the delay setting mode, and the “+/-“, “Minutes”, and delay icons light up.
  • Press the “+/-” key to adjust the delay duration; the screen displays the delay duration and flashes.
  • After 10 seconds of no operation, the delay icon remains lit, and the countdown begins.
  • After the delay ends, the delay icon turns off, and the warm air function shuts down.

10.3 Result Determination and Data Recording

10.3.1 Result Determination Standards

  • Pass: All test steps pass verification, with no faults occurring.
  • Fail: Any test step fails verification, or any fault occurs.
  • Pending Retest: Verification failure caused by environmental interference or occasional factors, requiring re-testing.

10.3.2 Data Recording Content

The software will automatically record the following test data:

  • Test date and time.
  • Remote control serial number.
  • Test personnel.
  • Test flow name.
  • Number of cycles.
  • Execution result of each step (pass/fail).
  • Time and step of fault occurrence.
  • Fault phenomenon description.
  • Total test duration.

10.3.3 Data Export and Report Generation

1. After the test is completed, click the “Save Recognition Results” button and select the save path.

2. The software will save the test data as a CSV format file.

3. Excel can be used to open the CSV file for data statistics and analysis.

4. Generate test reports as needed, including pass rate, fault distribution, average test time, and other information.

Part 11: Common Fault Troubleshooting

During equipment operation, various faults may be encountered. This section lists common fault phenomena, possible causes, and solutions to help you quickly troubleshoot and resolve problems.

11.1 Hardware Fault Troubleshooting

11.1.1 Robotic Arm Does Not Move

  • Fault Phenomenon: After the software sends a command, the robotic arm does not respond.
  • Possible Causes and Solutions:
  • Power not connected: Check whether the control board power adapter is plugged in, whether the power switch is on, and whether the control board power indicator light is lit.
  • Serial port not connected: Check whether the software has successfully established a serial connection with the control board and whether the COM number is correct.
  • Motor cable loose or reversed: Check whether all motor cables are plugged in securely and whether the connectors are reversed.
  • Control board fault: Use the serial port debugging tool to send a G-code command. If there is no response, the control board may be faulty; contact the supplier for replacement.
  • Motor fault: If only one axis does not move, the motor of that axis may be faulty; contact the supplier for replacement.
  • Limit switch triggered: Check whether the robotic arm is at a limit position. If so, manually move the robotic arm away from the limit position.

11.1.2 Robotic Arm Movement Jamming or Abnormal Noise

  • Fault Phenomenon: The robotic arm movement is not smooth, with jamming or abnormal noise.
  • Possible Causes and Solutions:
  • Foreign objects on guide rail: Power off and clean dust and debris from the guide rail.
  • Insufficient guide rail lubrication: Apply an appropriate amount of lubricating oil to the guide rail.
  • Screws too tight: Check whether the fixing screws of the guide rail and motor are too tight and adjust appropriately.
  • Timing belt too tight or too loose: Adjust the tension of the timing belt.
  • Bearing damage: If the abnormal noise is severe, the bearing may be damaged; contact the supplier for replacement.

11.1.3 Press Position Offset

  • Fault Phenomenon: The robotic arm press position is inaccurate, deviating from the key center.
  • Possible Causes and Solutions:
  • Inaccurate coordinate calibration: Re-perform coordinate calibration.
  • Camera moved: Check whether the camera has been moved. If so, re-calibrate the coordinates.
  • Remote control moved: Check whether the remote control has moved in the fixture. If so, re-fix the remote control and re-calibrate the coordinates.
  • Robotic arm loose: Check whether the fixing screws of the robotic arm are loose and tighten them.
  • Z-axis tilted: Check whether the Z-axis is vertical and adjust the Z-axis angle.

11.1.4 Camera Image Blurry or No Image

  • Fault Phenomenon: The image preview area is blurry, or no image is displayed.
  • Possible Causes and Solutions:
  • Camera lens dirty: Use a clean soft cloth to wipe the camera lens.
  • Camera focal length incorrect: Adjust the camera focal length until the image is clear.
  • Fill light brightness inappropriate: Adjust the fill light brightness to avoid being too dark or overexposed.
  • Camera driver abnormal: Reinstall the camera driver.
  • USB cable loose or damaged: Re-plug the USB cable, or replace the USB cable.
  • Camera fault: If none of the above methods work, the camera may be faulty; contact the supplier for replacement.

11.1.5 Key Press Ineffective

  • Fault Phenomenon: The robotic arm presses the key, but the remote control does not respond.
  • Possible Causes and Solutions:
  • Insufficient downward travel: Increase the downward travel to 7-8mm.
  • Hold time too short: Extend the hold time to 100ms.
  • Press position offset: Fine-tune the X/Y coordinates to ensure the press head is aligned with the key center.
  • Remote control fault: Manually press the key. If there is also no response, the remote control is faulty.
  • Main unit fault: Check whether the main unit is powered on normally and whether it is successfully paired with the remote control.

11.2 Software Troubleshooting

11.2.1 Software Fails to Start

Fault Symptom: After double-clicking the software shortcut, the software does not respond, or reports an error and exits.

Possible Causes and Solutions:

  • Missing Runtime Libraries: Install the runtime libraries required by the software (e.g., VC++ Runtime, .NET Framework, etc.).
  • Chinese Characters or Spaces in Installation Path: Reinstall the software to a path without Chinese characters or spaces.
  • Insufficient Permissions: Right-click the software shortcut and select “Run as administrator”.
  • Corrupted Software Files: Reinstall the software.
  • System Incompatibility: Confirm that the operating system is Windows 7 or Windows 10, not other systems.

11.2.2 Serial Port Connection Failure

Fault Symptom: After clicking the “Open Machine” button, the prompt “Serial port open failed” appears.

Possible Causes and Solutions: Refer to Section 4.3.1.

11.2.3 Coordinate Calibration Error

Fault Symptom: During the coordinate calibration process or the testing process, the prompt “Recognition result is not a coordinate parameter” or “Coordinate invalid” appears.

Possible Causes and Solutions: Refer to Section 7.1, re-perform the three-step calibration.

11.2.4 Program Reaches Point but Does Not Press Down

Fault Symptom: The manipulator moves to above the key, but the Z-axis does not descend to press.

Possible Causes and Solutions: Refer to Section 8.1.

11.2.5 Image Recognition Failure

Fault Symptom: The software cannot recognize image features, causing verification failure.

Possible Causes and Solutions:

  • Lighting Changes: Adjust the brightness of the fill light and keep the lighting stable.
  • Image Template Mismatch: Re-capture the image template.
  • Recognition Threshold Set Too High: Appropriately lower the recognition similarity threshold.
  • Camera Image Drift: Re-calibrate the coordinates.
  • Dirt on Remote Control Surface: Clean the remote control surface.

11.2.6 Software Running Laggy

Fault Symptom: The software runs slowly and responds slowly.

Possible Causes and Solutions:

  • Insufficient Computer Configuration: Upgrade computer hardware, especially memory and CPU.
  • Too Many Background Processes: Close unnecessary background programs.
  • Incorrect Software Settings: Lower the camera resolution (not recommended below 1920×1080), disable unnecessary functions.
  • Insufficient Hard Disk Space: Clean up hard disk space to ensure sufficient free space.
  • Software Version Too Old: Update to the latest version of the software.

11.3 Remote Control Troubleshooting

11.3.1 Remote Control Has No Display

Fault Symptom: The remote control screen does not light up and shows no display.

Possible Causes and Solutions:

  • Power Not Connected: Check if the remote control’s power wiring is secure and the voltage is normal.
  • Power Switch Not Turned On: Turn on the remote control’s power switch.
  • Blown Fuse: Check if the remote control’s fuse is blown; if so, replace it with a fuse of the same specification.
  • Circuit Board Fault: If the above methods are ineffective, the remote control circuit board may be faulty; contact the supplier for repair.

11.3.2 Key Not Responding

Fault Symptom: Pressing a key, the remote control has no response.

Possible Causes and Solutions:

  • Key Stuck: Check if the key is stuck by foreign objects, and clean them out.
  • Key Damaged: Replace the damaged key.
  • Circuit Board Fault: Possibly a fault in the key circuit or the main control circuit; contact the supplier for repair.
  • Not Paired with Host: Re-perform the pairing operation.

11.3.3 Pairing Failure

Fault Symptom: Unable to pair successfully with the host.

Possible Causes and Solutions: Refer to Section 6.4.

11.3.4 Incorrect Function Triggered

Fault Symptom: Pressing one key triggers a different function.

Possible Causes and Solutions:

  • Circuit Board Short Circuit: Check if the remote control circuit board has a short circuit.
  • Program Error: Restore factory settings, re-upgrade the firmware.
  • Electromagnetic Interference: Stay away from strong electromagnetic interference sources.

To ensure the long-term stable operation of the equipment and extend its service life, regular maintenance and care are required.

12.1 Daily Maintenance (Daily)

  • Clean Equipment Surface: Use a clean soft cloth to wipe the equipment surface to remove dust and stains.
  • Clean Camera Lens: Use lens paper or a clean soft cloth to gently wipe the camera lens to keep it clean.
  • Check the Pressing Head: Check if the silicone pressing head has wear, deformation, or damage; replace it promptly if damaged.
  • Check Cables: Check all cables for breakage, aging, or looseness; address any issues promptly.
  • Check Fixtures: Check if the remote control fixture is loose or deformed, ensuring the remote control is firmly fixed.
  • Check Indicator Lights: Check if all indicator lights display correctly.

12.2 Weekly Maintenance

  • Clean Guide Rails: Use a clean soft cloth to wipe the guide rails, removing dust and debris, then apply a small amount of lubricating oil.
  • Tighten Screws: Check if all fixing screws are loose, especially those on critical parts like the manipulator base, guide rails, motors, and camera brackets; tighten if loose.
  • Calibrate Coordinates: Perform a coordinate calibration to ensure accurate pressing positions.
  • Test All Functions: Run a complete test cycle to check if all equipment functions are normal.
  • Back Up Data: Back up this week’s test data and software configuration files.

12.3 Monthly Maintenance

  • Deep Clean Equipment: Perform a thorough cleaning of the equipment, including dust and debris inside the equipment.
  • Check Motor Operating Status: Check the motors for abnormal noise or overheating during operation; address any issues promptly.
  • Check Timing Belt: Check the tension and wear of the timing belt; adjust or replace if loose or worn.
  • Check Power Adapter: Check the power adapter for overheating or abnormal noise; replace if problematic.
  • Update Software: Check for software updates and upgrade to the latest version promptly if available.

12.4 Annual Maintenance

  • Comprehensive Equipment Inspection: Conduct a full inspection of the equipment, including mechanical structure, electrical system, and software system.
  • Replace Wear Parts: Replace severely worn wear parts, such as silicone pressing heads, timing belts, bearings, etc.
  • Lubricate All Moving Parts: Perform comprehensive lubrication on all moving parts.
  • Calibrate Equipment Accuracy: Perform a comprehensive calibration of the equipment’s positioning accuracy and pressing accuracy.
  • Conduct Performance Testing: Conduct a comprehensive performance test on the equipment to ensure it meets requirements.

12.5 Maintenance Precautions

  • Power Off Operation: Before any maintenance or care operation, you must turn off the equipment power and unplug the power plug.
  • Use Appropriate Tools: Use appropriate tools for maintenance operations to avoid damaging the equipment.
  • Avoid Corrosive Cleaners: Do not use corrosive cleaners to wipe the equipment surface, to avoid damaging the equipment’s appearance.
  • Do Not Disassemble Equipment Yourself: Do not disassemble core components of the equipment yourself, such as the control board, motors, etc. Contact the supplier for repair if there are issues.
  • Maintain Maintenance Log: Establish an equipment maintenance log, recording the time, content, and results of each maintenance.

To ensure the personal safety of operators and the safe operation of the equipment, the following safety regulations must be strictly followed:

13.1 Installation Safety Regulations

  • Installer Requirements: Equipment installation must be carried out by trained professionals.
  • Power Off Installation: All installation operations must be performed in a power-off state.
  • Grounding Requirements: The equipment must be reliably grounded to prevent electric shock.
  • Power Requirements: Use a power supply that meets requirements and avoid sharing a power outlet with high-power appliances.
  • Installation Location: The equipment should be installed on a stable, sturdy workbench, away from water sources, fire sources, and strong electromagnetic interference sources.
  • Space Requirements: Sufficient operating space should be reserved around the equipment for installation, commissioning, and maintenance.

13.2 Operation Safety Regulations

  • Operator Requirements: Operators must be trained and familiar with the equipment’s operation methods and safety regulations.
  • No Reaching In: It is strictly forbidden to insert hands, head, or other objects into the manipulator’s movement range while the equipment is running.
  • Emergency Stop: In case of an emergency, immediately press the emergency stop button or cut off the power.
  • Unattended Operation: For long periods of unattended operation, arrange for personnel to check periodically.
  • No Modification: Privately modifying the equipment’s hardware and software is strictly forbidden.
  • Load Limit: Using the equipment beyond its rated load is strictly forbidden.
  • Movement Speed: Do not arbitrarily increase the manipulator’s movement speed to avoid danger.

13.3 Maintenance Safety Regulations

  • Power Off Maintenance: Before any maintenance or care operation, you must turn off the equipment power and unplug the power plug.
  • Tool Use: Use appropriate tools for maintenance operations, avoiding damaged tools.
  • Part Replacement: When replacing parts, use original or equivalent specification parts.
  • Electrostatic Protection: Take electrostatic protection measures, such as wearing an anti-static wrist strap, when contacting electronic components like circuit boards.
  • Waste Disposal: Waste parts and materials should be disposed of according to environmental requirements.

13.4 Fire Safety Regulations

  • Equip Firefighting Equipment: Equip appropriate firefighting equipment, such as dry powder fire extinguishers, near the equipment.
  • No Smoking: Smoking is prohibited in the equipment operating area.
  • Stay Away from Fire Sources: The equipment should be kept away from fire sources and flammable/explosive materials.
  • Handle Fire Promptly: In case of fire, immediately cut off the power, use the firefighting equipment to extinguish the fire, and call the fire department.

13.5 Emergency Handling

  • Electric Shock Accident: Immediately cut off the power, or use a dry insulating object to separate the victim from the power source, then perform first aid and call the emergency number.
  • Fire Accident: Immediately cut off the power, use a dry powder fire extinguisher to extinguish the fire (Do NOT use water), then call the fire department.
  • Mechanical Injury Accident: Immediately stop the equipment, provide first aid to the injured, and call the emergency number.
  • Equipment Failure: Immediately stop the equipment, cut off the power, and contact the supplier for repair.

14.1 Warranty Policy

  • Warranty Period: The complete equipment is warranted for 1 year; wear parts (such as silicone pressing heads, timing belts, etc.) are warranted for 3 months.
  • Warranty Coverage: Within the warranty period, faults caused by equipment quality issues will be repaired free of charge, including replacement parts.
  • Non-Warranty Coverage:
  • Faults caused by human damage, misuse, or abuse.
  • Faults caused by natural disasters or force majeure.
  • Faults caused by unauthorized modification or disassembly of the equipment.
  • Faults caused by failure to operate and maintain according to the manual’s instructions.
  • Normal wear of wear parts.

14.2 Technical Support

We provide comprehensive technical support services to help you solve various problems encountered during equipment use:

  • Phone Technical Support: Provides 7×24-hour phone technical support. You can call the technical support hotline anytime for consultation.
  • Technical Support Hotline: +86 13538869979
  • Email Technical Support: You can send your issues to the technical support email, and we will reply within 24 hours.
  • Email Address: +86 13538869979@139.com
  • Remote Technical Support: With your permission, we can assist you in resolving software issues via remote desktop.
  • On-Site Technical Support: For issues that cannot be resolved by phone or remotely, we will arrange for technicians to provide on-site service.

14.3 Repair Service Process

1. Fault Reporting: When equipment failure occurs, contact our technical support promptly to report the fault.

2. Fault Diagnosis: Technical support staff will diagnose the fault via phone, email, or remote access.

3. Solution: Based on the diagnosis results, technical support staff will provide appropriate solutions.

4. Repair Implementation: If parts replacement or on-site repair is needed, we will arrange for technicians to perform the repair.

5. Acceptance Confirmation: After the repair is complete, you need to confirm and accept the repair results.

6. Follow-up Service: After repair, we will provide follow-up service to ensure the equipment operates normally.

14.4 Training Services

We provide professional training services to help your operators quickly master the equipment’s usage and maintenance methods:

  • On-Site Training: After equipment installation and commissioning, our technicians will provide on-site training for operators, covering equipment operation, daily maintenance, and common troubleshooting.
  • Regular Training: We will regularly hold training sessions for advanced operator training, covering advanced feature usage, equipment calibration, and in-depth maintenance.
  • Online Training: We provide online training videos and documents that you can watch and learn from at any time.

15.1 Standard Parameter Summary Table

Parameter Category Parameter Name Standard Value
System Parameters Computer Display Resolution 1920×1080
Serial Port Baud Rate 95200
Data Bits 8
Stop Bits 1
Parity None
Manipulator Parameters X-axis Travel 470mm
Y-axis Travel 300mm
Z-axis Travel 50mm
Repeated Positioning Accuracy ±0.05mm
Maximum Movement Speed 3000mm/min
Action Parameters Press Duration (Touch Switch) 60-100ms
Lowering Height (Touch Switch) 6-8mm
Rising Height 1-2mm
Click delay after success 200-300ms
Delay to next step after success 800-1000ms
Camera Parameters Resolution 1920×1080
Frame Rate 30fps
Interface USB3.0
Power Parameters Input Voltage AC 220V±10% 50Hz
Output Voltage DC 24V
Output Current 5A
Environmental Parameters Working Temperature 10℃-35℃
Working Humidity 30%-80%RH

15.2 Common G-Code Instruction Table

Instruction Function Example
G1 Xn Yn F3000 Move to X/Y coordinate G1 X33 Y85 F3000
G1 Z-n F1000 Z-axis descends n mm G1 Z-6 F1000
G1 Z0 F1000 Z-axis rises and resets G1 Z0 F1000
G4 Pn Delay for n milliseconds G4 P1000
M0 Program pause M0
M2 Program end M2

15.3 Fault Code Table

Fault Code Fault Symptom Possible Cause Solution
E001 Serial port open failed Wrong port selected, driver abnormal, loose cable Verify COM number, reconnect USB cable, update driver
E002 Invalid coordinate Coordinates not calibrated, wrong coordinate values Perform the three-step calibration again
E003 Manipulator not responding Control board fault, motor cable plugged in reverse Check control board and motor cables
E004 Image recognition failed Light changes, template mismatch Adjust lighting, re-capture template
E005 Limit trigger Manipulator moved beyond its range Manually move the manipulator away from the limit position
E006 Motor overload Excessive load, motor jammed Reduce load, clear foreign objects
E007 No camera image Camera not connected, driver abnormal Reconnect USB cable, update driver
E008 Pairing failed Distance too far, interference, device fault Shorten distance, eliminate interference, check device

15.4 Contact Information

  • Company Name:
  • Company Address:
  • Telephone:
  • Fax:
  • Email:
  • Website:

Thank you for choosing our Dual-Station Fixture Manipulator Remote Control Automated Testing System. This manual provides detailed information on system installation, commissioning, operation, maintenance, and troubleshooting. We hope it helps you quickly master the equipment’s usage and fully utilize its performance.

If you encounter any problems during use, please do not hesitate to contact our technical support team. We are dedicated to serving you. Additionally, we welcome your valuable feedback and suggestions to help us continuously improve our products and services.

We wish you pleasant use!