Antivirus Gateway Installation Manual

Network Security Protection Equipment · Lain LA-AV Series

Manufacturer: Guangdong Lain Intelligent Computer Room Equipment Co., Ltd.

Document Version: V3.2

Release Date: July 2026

Applicable Models: LA-AV100, LA-AV500, LA-AV2000, LA-AV5000, LA-AV10000, LA-AV Industrial Control Series

Table of Contents

Preface

This manual is the official installation, wiring, and commissioning guidance document for the LA-AV Series Antivirus Gateway, independently developed by Guangdong Lain Intelligent Computer Room Equipment Co., Ltd. It is intended to provide engineering construction personnel, network operations personnel, and security management personnel with comprehensive, standardized, and actionable guidance covering the full lifecycle of device deployment, configuration, commissioning, and operation and maintenance.

This manual is compiled in strict compliance with national and industry standards including *GB/T 35277-2017 Information Security Technology — Security Technical Requirements and Testing Evaluation Methods for Antivirus Gateway* and the *Baseline for Classified Protection of Cybersecurity 2.0*, covering technical points across the entire product lifecycle. It also incorporates industry-leading technical norms including domestic (indigenous) adaptation, industrial control scenario protection, and high-availability deployment.

Target Audience

  • System integrator engineering and construction personnel
  • Network operations engineers at enterprise/government entities
  • Information security administrators
  • Computer room operations and technical support personnel
  • Classified Protection (MLPS) evaluation and compliance audit personnel

Terminology and Definitions

Term Definition
Antivirus Gateway (AVG) A dedicated network security device deployed at network boundaries or key nodes that performs deep packet inspection of traffic entering and leaving the network, and detects, intercepts, and removes malicious code including viruses, Trojans, ransomware, and worms in real time.
Bypass A hardware bypass mechanism that automatically places business interfaces into a physical pass-through state when the device is powered off or suffers a system fault, ensuring the network link remains uninterrupted.
Signature Database A database storing fingerprints of malicious code characteristics; the core basis for virus detection.
Transparent Bridge Mode A deployment mode in which the device operates as a “cable splice,” requiring no modification to upstream/downstream network IP configurations — plug-and-play deployment.
Sandbox Detection A detection technology that dynamically executes suspicious files in a virtual execution environment to identify unknown threats.
TPS Transactions per second (new connections per second); a core indicator for measuring the gateway’s concurrent processing capability.

Reference Standards

Standard Title
GB/T 35277-2017 Information Security Technology — Security Technical Requirements and Testing Evaluation Methods for Antivirus Gateway
GB/T 22239-2019 Information Security Technology — Baseline for Classified Protection of Cybersecurity
GB/T 25000.51-2016 Systems and Software Engineering — Systems and Software Quality Requirements and Evaluation (SQuaRE)
YD/T 2407-2018 Technical Requirements for Internet-Oriented Malicious Program Protection Systems
ISO/IEC 27033-3:2010 Information Technology — Security Techniques — Network Security — Part 3: Reference Networking Scenarios

Chapter 1: Product Introduction

1.1 Product Definition

The Antivirus Gateway is a core malicious-code protection device within the network boundary security protection system, falling within the application-layer security gateway category. By performing deep parsing of data at the network transport layer and application layer, it conducts real-time virus scanning and malicious behavior detection on file content carried by mainstream protocols including HTTP, HTTPS, FTP, SMTP, POP3, IMAP, and SMB. Malicious code is intercepted and removed before it can enter the internal network or critical business areas, establishing a centralized “gateway-style” virus defense system.

Unlike traditional endpoint antivirus software, the Antivirus Gateway advances protection capability to the network entry point, blocking virus propagation chains at the source and preventing lateral spread within the internal network. It also resolves the pain points of endpoint antivirus software, including decentralized deployment, complex upgrade management, and susceptibility to termination by malicious programs. It is an indispensable core device for government and enterprise organizations building a “gateway + endpoint” multi-layered virus protection system.

1.2 Product Development Background and History

1.2.1 Evolution of Network Virus Threats

Since the widespread adoption of the Internet, malicious code has remained one of the core threats to network security. Early viruses primarily propagated through physical media such as floppy disks and optical discs. With the growth of the Internet, web downloads, email attachments, and file sharing became the primary channels for virus propagation. After 2010, ransomware, cryptomining malware, and targeted APT attacks grew explosively, and traditional endpoint protection could no longer cope with rapidly evolving threats:

  • Ransomware invades in large batches through phishing emails and vulnerability exploitation; once it spreads within the internal network, it can cause enormous losses.
  • Cryptomining malware propagates laterally by exploiting system vulnerabilities, consuming massive computing resources.
  • Malicious code employs evasion techniques such as packing, metamorphism, and encrypted transmission, making endpoint detection and removal increasingly difficult.

Against this backdrop, the Antivirus Gateway, which positions protection capability at the network boundary, emerged and became a standard device in network security architecture.

1.2.2 Technology Development History of Antivirus Gateways

First Generation (2000–2008): Basic Protocol Scanning Stage

Supported only simple file scanning of a few basic protocols such as HTTP, FTP, and SMTP, based on pure signature matching. Detection rates were low and performance overhead was high, with most implementations integrated as software modules within firewalls.

Second Generation (2009–2015): Dedicated Hardware Acceleration Stage

Standalone hardware-form antivirus gateways emerged, employing dedicated network processors and hardware acceleration chips. Multi-protocol deep parsing was supported, and heuristic scanning technology was introduced. Detection capability and performance improved significantly, and high-availability mechanisms such as Bypass began to be supported.

Third Generation (2016–2022): Multi-Engine Fusion Detection Stage

Integrated multiple detection engines including signature, heuristic, behavior analysis, sandbox, and AI. Encrypted traffic detection was supported, specialized threats such as ransomware and cryptomining were identifiable, and integration with cloud threat intelligence enabled rapid response to unknown threats.

Fourth Generation (2023 to Present): Intelligent Native Protection Stage

Domestic (indigenous) and independently controllable technology became a core trend. AI large-model detection engines became widespread, with support for industrial control protocols and cloud-native scenario protection. Threat hunting, automated response, and collaborative linkage capabilities were included, evolving from a purely “interception device” into a “boundary threat intelligence hub.”

The Lain LA-AV Series Antivirus Gateway belongs to the fourth generation. Built on a domestically-produced, independently controllable secure operating system with a multi-engine detection architecture, it is fully adapted to the Xinchuang (IT innovation) environment and MLPS 2.0 requirements, covering full-scenario protection needs from small offices to carrier-grade deployments.

1.3 Product Positioning in the Network Security Architecture

In a complete network defense-in-depth architecture, the Antivirus Gateway occupies the application security dimension of the “boundary protection layer.” Together with firewalls, Intrusion Prevention Systems (IPS), Internet Behavior Management, and Web Application Firewalls (WAF), it forms a boundary security protection matrix, with each device assuming different protection responsibilities:

Device Type Core Protection Layer Core Protection Objective Collaborative Relationship with Antivirus Gateway
Firewall Network layer / Transport layer Access control, port filtering, NAT Provides basic network isolation; antivirus gateway is connected in series behind it for deep content inspection
IPS (Intrusion Prevention System) Network layer / Application layer Vulnerability attacks, intrusion behavior, abnormal traffic Blocks attack behavior; antivirus gateway blocks malicious code carried in attack payloads
Antivirus Gateway Application layer / Content layer Viruses, Trojans, ransomware, cryptomining and other malicious code Focused on malicious code detection, supplementing the content protection gaps of firewalls and IPS
WAF (Web Application Firewall) Application layer (Web) SQL injection, XSS, web vulnerability attacks Protects against web application attacks; antivirus gateway protects against malicious files downloaded/uploaded over the web
Endpoint Antivirus Software Endpoint host layer Local virus detection and removal, host hardening Forms “entry + endpoint” dual protection with the gateway; heterogeneous engines improve detection rates

The core value of the Antivirus Gateway lies in filling the gap of “centralized malicious code prevention and control at the network boundary,” intercepting more than 90% of known viruses at the network entry point, substantially reducing endpoint protection pressure and the risk of internal network infection.

1.4 Differences Between the Antivirus Gateway and Endpoint Antivirus Software

Many users question whether an Antivirus Gateway is still needed when endpoint antivirus is already installed. The two are not alternatives but complements. The core differences are as follows:

1.4.1 Different Deployment Locations and Protection Scope

Endpoint antivirus software is deployed on each individual host/server, with protection scope limited to that single device. The Antivirus Gateway is deployed at the network boundary or zone boundary, where a single device can protect all terminals across an entire network segment with centralized management and control.

1.4.2 Different Protection Timing

Endpoint antivirus provides “post-event protection” — viruses are only detected and removed after they have already entered the terminal, and some stealthy viruses may already have executed malicious operations. The Antivirus Gateway provides “pre-event protection” — viruses are intercepted before they even enter the internal network, cutting off propagation at the source.

1.4.3 Different Management and Maintenance Costs

Endpoint antivirus requires individual deployment, upgrade, and troubleshooting on every machine; the operational workload becomes enormous when the number of endpoints is large. The Antivirus Gateway requires maintenance of only a single device — one virus signature database takes effect across the entire network, resulting in extremely low operational costs.

1.4.4 Different Tamper-Resistance Capabilities

Endpoint antivirus software runs on user operating systems and can be forcibly terminated or uninstalled by viruses and Trojans. The Antivirus Gateway is a standalone hardware device with a dedicated closed system that cannot be interfered with by endpoint malicious programs, providing higher protection reliability.

1.4.5 Complementary Detection Capabilities

When the two employ detection engines from different vendors, they form “heterogeneous protection.” The probability of a virus bypassing one engine is far lower than bypassing both simultaneously, substantially improving the overall detection rate.

The common industry practice is: core networks must deploy an Antivirus Gateway as the first line of defense, supplemented by endpoint antivirus software as the second line, to build a multi-layered defense system.

1.5 Differences Between the Antivirus Gateway and UTM/Next-Generation Firewalls

Many security devices on the market integrate antivirus functionality, such as UTM and NGFW (Next-Generation Firewall). However, the dedicated Antivirus Gateway still offers irreplaceable advantages:

1.5.1 Different Functional Positioning

UTM/NGFW devices are “all-in-one” devices where antivirus is merely one of many functions, and hardware resources and engine optimization priorities are subordinate to core firewall functions. The dedicated Antivirus Gateway is a “specialist” device — all hardware resources and software optimization are focused on virus detection, providing superior detection depth, scanning performance, and protocol support compared to integrated functionality.

1.5.2 Different Detection Performance

When antivirus functionality is enabled on UTM/NGFW devices, overall throughput typically drops by 50%–70%, and performance bottlenecks are likely at high traffic volumes. The dedicated Antivirus Gateway provides hardware acceleration specifically for virus scanning — performance degradation when full-feature scanning is enabled is less than 20%, with greater stability under high load.

1.5.3 Different Detection Depth

Integrated antivirus functionality typically supports only basic signature-based detection, with limited capability to detect packed, multi-layer compressed, or encrypted files. The dedicated Antivirus Gateway supports deep unpacking, sandbox dynamic detection, and AI-based intelligent recognition, providing significantly stronger detection of unknown threats and polymorphic viruses.

1.5.4 Different Applicable Scenarios

Small networks or budget-constrained scenarios may select UTM/NGFW with integrated antivirus functionality. Medium-to-large networks, high-security-grade scenarios, and scenarios with strict MLPS compliance requirements must deploy a dedicated Antivirus Gateway.

1.6 Product Compliance Value and MLPS Adaptability

The Antivirus Gateway is one of the mandated devices under the Cybersecurity Classified Protection 2.0 standard, corresponding to the “Secure Computing Environment — Malicious Code Prevention” and “Secure Communication Network — Boundary Protection” requirements:

Level 2 MLPS Requirements: Anti-malicious-code software or software with equivalent functionality must be installed, with regular upgrades and updates to the anti-malicious-code database; access control devices must be deployed at the boundary.

Level 3 MLPS Requirements: Malicious code detection and protection devices must be deployed at the network boundary or key nodes to perform malicious code detection on information entering and leaving the network; a heterogeneous-architecture malicious code protection system should be adopted.

Level 4 MLPS Requirements: Malicious code must be detected and removed at key network nodes, with maintenance of upgrades and updates to the malicious code protection mechanism; a multi-layered malicious code defense system must be established.

Deploying the Lain LA-AV Series Antivirus Gateway directly satisfies the boundary protection requirements of MLPS malicious code prevention. Combined with endpoint antivirus to form heterogeneous protection, it fully meets Level 3 and above MLPS evaluation standards, while also satisfying specialized compliance requirements in industries such as finance, energy, and healthcare.

1.7 Lain LA-AV Series Antivirus Gateway Product Positioning and Advantages

Guangdong Lain Intelligent Computer Room Equipment Co., Ltd. has been deeply engaged in the fields of computer room security and network boundary protection for many years. The LA-AV Series Antivirus Gateway is a core security product developed by the company based on a domestically-produced technology roadmap, positioned as a “high-reliability, easy-to-deploy, strong-detection boundary virus protection expert.” Its core advantages include:

  • Fully self-developed, domestically-produced architecture: Based on a domestically-produced, independently controllable secure operating system and a self-developed virus detection engine, with core software and hardware fully produced domestically, meeting Xinchuang scenario requirements.
  • Multi-engine fusion detection: Integrates four detection engines — signature, heuristic, behavior analysis, and AI deep learning — achieving a virus detection rate of over 99.8% with effective identification of unknown threats.
  • High performance with low overhead: Equipped with dedicated network processing chips and hardware acceleration engines. The 10-Gigabit model achieves a fully-configured scanning throughput of over 8 Gbps with latency below 1 ms.
  • All-scenario deployment adaptability: Supports three deployment modes — transparent bridge, routing, and bypass mirroring — plug-and-play, requiring no changes to the existing network architecture.
  • Industrial-grade high-reliability design: Hardware Bypass is standard across the entire series, with support for dual redundant power supplies and dual-machine hot standby. Mean Time Between Failures (MTBF) exceeds 100,000 hours.
  • Full-industry protocol coverage: In addition to general Internet protocols, supports virus detection for industrial control protocols including Modbus, IEC 104, and IEC 61850, suitable for industrial control scenarios.
  • Localized service support: The manufacturer provides 7×24 technical support, and multiple nationwide service locations offer on-site installation, commissioning, and operations support.

Chapter 2: Product Composition

The LA-AV Series Antivirus Gateway adopts an integrated architecture of “dedicated hardware platform + embedded security software system,” with hardware and software deeply co-optimized to jointly deliver high-performance, high-reliability virus protection capability.

2.1 Hardware System Composition

2.1.1 Chassis Structure

All LA-AV Series models feature a standard 19-inch rack-mount chassis design. Entry-level models are 1U in height, mid-range models are 2U, and high-end data center models are 4U. The chassis is constructed from high-quality SECC galvanized steel sheet, providing excellent electromagnetic shielding and dust resistance, with an anti-static powder-coated surface finish.

The front panel integrates the power indicator, operation indicator, alarm indicator, interface status indicators, USB ports, and power switch (on select models). The rear panel integrates the business network ports, management port, Console port, grounding terminal, power connectors, and fan modules.

The interior of the chassis uses a modular layout divided into four independent zones: power supply zone, core computing zone, interface zone, and cooling zone. The airflow design uses front-to-rear straight-through ventilation, ensuring heat dissipation efficiency while reducing dust accumulation.

2.1.2 Power Supply Modules

The power supply is the foundation for stable device operation. The LA-AV Series employs industrial-grade switching power supplies with multiple reliability designs including wide-voltage input, overcurrent protection, overvoltage protection, short-circuit protection, and surge protection.

  • Entry-level models (LA-AV100/500): Standard single AC power supply, input voltage 100–240 V~ 50/60 Hz, power rating 150 W–300 W.
  • Mid-to-high-end models (LA-AV2000/5000/10000): Standard 1+1 redundant AC power supplies with hot-swap support; failure of a single power supply does not affect device operation. Input voltage 100–240 V~ 50/60 Hz, power rating 500 W–1500 W.
  • Industrial control custom models: Support DC power input (DC -48 V/24 V), suitable for telecommunications equipment rooms and industrial field power environments.

All power supply modules pass 3C, CE, and other safety certifications, with electromagnetic compatibility conforming to the GB/T 17626 standard.

2.1.3 Core Processing Unit

The core processing unit is the “brain” of the device, responsible for the complete processing flow of traffic forwarding, protocol parsing, and virus detection. The LA-AV Series uses a heterogeneous computing architecture of “general-purpose multi-core CPU + dedicated network co-processor”:

  • Main CPU: Adopts domestically-produced Phytium/Hygon multi-core processors (or Intel Xeon processors, optional), with 4–32 cores, responsible for management-plane and control-plane computation and complex detection logic.
  • Network Co-processor: Equipped with dedicated multi-core network processors (NP), responsible for basic traffic forwarding, protocol preprocessing, and high-speed signature matching, substantially reducing the main CPU load and improving forwarding performance.
  • Content Acceleration Engine: Integrates hardware regular-expression matching engines, compression/decompression acceleration engines, and encryption/decryption acceleration engines, specifically providing hardware acceleration for virus scanning scenarios.

This heterogeneous architecture ensures both the flexibility of complex detection logic and forwarding performance under high traffic, avoiding the performance bottleneck of pure CPU architectures under high load.

2.1.4 Memory and Storage System

Memory System

Memory is used to cache network sessions, temporary files, running processes, and the signature database, and is a key hardware component affecting concurrent performance and scanning speed.

Model Tier Standard Configuration Maximum Supported
Entry-level models 8 GB DDR4 16 GB
Enterprise models 16 GB–32 GB DDR4 64 GB
High-end models 64 GB–128 GB DDR4 256 GB

All models use ECC error-correcting memory to ensure system stability and prevent system crashes caused by memory errors.

Storage System

Storage is used to install the operating system, save configuration files, store the virus signature database, and record logs and reports.

  • System disk: Industrial-grade SSD solid-state drives, 64 GB–512 GB capacity, with fast read/write speeds, shock and vibration resistance, and high reliability, avoiding system damage caused by mechanical hard disk failures.
  • Log disk: Mid-to-high-end models come standard with a dedicated log disk of 1 TB–4 TB SSD capacity for long-term log data storage, preventing logs from occupying system disk space.
  • Storage interfaces: Supports SATA 3.0 and M.2 NVMe interfaces; select high-end models support storage expansion slots.

2.1.5 Network Interface Modules

Network interfaces are the physical channels through which the device connects to the network, categorized into business interfaces and management interfaces. The LA-AV Series provides a rich set of interface configurations to suit different network environments.

Business Interfaces

Used to access user business traffic and perform virus scanning and forwarding. Interface types include:

Interface Type Description
RJ45 copper ports 10/100/1000 Mbps auto-negotiation, for Gigabit network access, 4–16 ports
SFP optical ports Gigabit/10-Gigabit auto-negotiation, compatible with single-mode and multi-mode optical modules, for long-distance, high-bandwidth link access, 2–8 ports
SFP+ 10-Gigabit optical ports 10 Gbps rate, for data center and core backbone links, 2–4 ports
QSFP+ 40G optical ports 40 Gbps rate, standard only on high-end models, for carrier-grade and large data center scenarios

All business interfaces support full-duplex mode, MDI/MDIX auto-crossover, and link aggregation.

Bypass Special Interfaces

Key business interfaces come standard with hardware Bypass functionality. When the device is powered off, frozen, or experiences a system failure, it automatically switches to a physical pass-through state, ensuring business links are not interrupted. Bypass interfaces are clearly marked with a “Bypass” label and appear in pairs (one set for ingress, one set for egress).

Management Interfaces

Used for device configuration management, independent of business interfaces, preventing management traffic from occupying business bandwidth while improving management security.

  • WEB management port: 1 RJ45 Gigabit copper port on a separate network segment, used for WEB interface management.
  • Console port: 1 RJ45 or RS232 serial port, used for command-line management and fault debugging, default baud rate 9600 bps.
  • USB ports: 1–2 USB 3.0 ports on the front panel, used for system recovery, configuration import/export, and local upgrades.

2.1.6 Status Indication System

Multiple groups of LED indicators are provided on the front panel to visually display device operating status for rapid fault diagnosis by operations personnel.

Indicator Name Color Status Meaning
POWER Green Steady on: power normal; Off: power not connected or fault
RUN Green Steady on: system running normally; Blinking: system starting up / data reading or writing; Off: system not running
ALM (Alarm) Red Steady on: critical fault (power supply, temperature, system anomaly); Blinking: general alarm (signature database expired, configuration anomaly); Off: no alarm
Interface status (one set per port) Green/Yellow Green steady on: link connected; Green blinking: data transmitting; Yellow steady on: 100 Mbps rate; Green steady on: Gigabit/10-Gigabit rate; Off: link not connected
HDD (Hard disk) Yellow Blinking: disk reading or writing; Off: no read/write activity

2.1.7 Cooling System

The LA-AV Series employs an intelligent temperature-controlled cooling system consisting of cooling fans and heat-dissipation fins. Fan speed is automatically adjusted based on internal device temperature, balancing cooling efficiency with noise control.

  • Entry-level models: Equipped with 2 40 mm high-speed fans with front-to-rear ventilation design.
  • Mid-to-high-end models: Equipped with 4–8 hot-swappable fan modules supporting N+1 redundancy; failure of a single fan does not affect cooling.
  • Industrial models: Optional fanless cooling design using full-chassis heat-dissipation fins, suitable for dusty, high-temperature industrial environments.

The cooling system supports temperature threshold alarms. When CPU temperature or internal chassis temperature exceeds the configured threshold, fan speed is automatically increased and an alarm is reported. When it exceeds the critical threshold, a protective automatic shutdown is triggered.

2.1.8 Bypass Hardware Module

Bypass is a core reliability component of the Antivirus Gateway. The LA-AV Series employs an independent hardware Bypass module that does not depend on the operating system or software configuration — fault switching is implemented through pure hardware logic, with switchover time of less than 10 ms, making the transition imperceptible to business operations.

Bypass module trigger conditions include:

  • Complete device power failure;
  • System kernel crash or process hang;
  • Manual triggering via WEB/CLI commands;
  • Watchdog timeout without receiving the system heartbeat.

Bypass modules are available in relay type and optical switch type. Copper ports use relay-based Bypass, while optical ports use optical switch-based Bypass. Both achieve industrial-grade service life with more than 100,000 operation cycles.

2.2 Software System Composition

The LA-AV Series Antivirus Gateway runs the self-developed ROS-Sec Security Operating System from Lain, trimmed and optimized based on a microkernel architecture, specifically customized for network security devices. It features high security, high stability, and high performance. The software system is divided into multiple functional modules, each with distinct responsibilities working in coordination.

2.2.1 Dedicated Security Operating System

The ROS-Sec Security Operating System is the foundation of the entire software system, with the following characteristics:

  • Kernel-level trimming: All unnecessary system services and ports are removed, minimizing the attack surface.
  • Mandatory access control: Kernel-level permission isolation is implemented; even administrators cannot access core system files beyond their authority.
  • Process protection: Key service processes are guarded by a watchdog and automatically restart on abnormal termination.
  • Encrypted storage: Configuration files, signature databases, and logs are all stored encrypted to prevent data leakage.
  • Domestic adaptation: Fully adapted to domestically-produced CPUs including Phytium, Loongson, Hygon, and Kunpeng, with support for domestic firmware.

2.2.2 Core Virus Detection Engine Cluster

The virus detection engine is the core functional module of the Antivirus Gateway. The LA-AV Series adopts a “four-engine fusion detection architecture,” with multiple engines performing parallel detection to balance detection rate and performance.

1. Signature Detection Engine

The most fundamental and mature detection engine, based on precise matching against the virus signature fingerprint database. Detection rate for known viruses approaches 100% with an extremely low false-positive rate.

  • Supports exact signature matching and fuzzy signature matching;
  • Supports high-speed retrieval of a signature database with tens of millions of entries, with hardware-accelerated matching;
  • Multiple incremental signature database updates per day to respond to new viruses.

2. Heuristic Detection Engine

Performs intelligent judgment based on virus behavior patterns and code structure, capable of detecting certain unknown polymorphic viruses without relying on the signature database.

  • Static heuristic: Analyzes file structure, entry points, and section information to identify suspicious packing and abnormal code;
  • Dynamic heuristic: Simulates execution of file instructions to identify typical virus behavior sequences.

3. Behavior Analysis Engine

Performs modeling and analysis of network behavior and system behavior after file execution, identifying malicious behaviors such as cryptomining, ransomware, and remote control.

  • Detects network behaviors including abnormal outbound connections, port scanning, and lateral movement;
  • Identifies host behaviors including file encryption, system modification, and privilege escalation;
  • Performs matching against the threat intelligence behavior signature database.

4. AI Deep Learning Engine

Based on deep learning neural network models trained on massive volumes of malicious samples, capable of identifying unknown threats and zero-day vulnerability attacks that traditional engines cannot detect.

  • Combines convolutional neural networks (CNN) with Transformer models;
  • Supports AI detection of static files and AI detection of traffic behavior;
  • Models are iteratively updated periodically through cloud updates to continuously improve detection capability.

2.2.3 Virus Signature Database and Threat Intelligence Database

Virus Signature Database

Stores the characteristic fingerprints of all known malicious code and serves as the working basis for the signature engine. The Lain virus signature database is divided into:

Database Type Content Update Frequency
Base virus database Signatures for mainstream viruses, Trojans, and worms Daily
Specialized threat database Ransomware database, cryptomining malware database, APT attack payload database Hourly
Malicious URL database Malicious website, phishing website, and compromised (malware-hosting) website address database Real-time
Industrial control virus database Malicious code signature database targeting industrial control systems Periodic

The full signature database exceeds 20 million entries and continues to grow.

Threat Intelligence Database

Global threat data provided by the cloud threat intelligence system, including malicious IPs, malicious domains, C&C server addresses, and attack group characteristics.

  • Supports local caching of high-demand intelligence with real-time cloud queries for cold data;
  • Threat intelligence is graded — high-level threats are blocked directly, while medium- and low-level threats generate alarms;
  • Supports user-defined intelligence import.

2.2.4 Protocol Deep Parsing Engine

Responsible for identifying and parsing various network application protocols, extracting file content contained therein and delivering it to the detection engines for scanning.

  • Supports automatic protocol identification without fixed ports, capable of identifying protocols running on non-standard ports;
  • Supports protocol state tracking with complete restoration of TCP sessions and file content;
  • Supports automatic decompression of compressed files and recursive decompression of nested archives;
  • Supports automatic unpacking of packed files;
  • Supports SSL/TLS encrypted traffic decryption and inspection (requires certificate import).

Supported protocols include: HTTP, HTTPS, FTP, SFTP, SMTP, POP3, IMAP, SMB/CIFS, NFS, Telnet, SSH, Modbus, IEC 104, IEC 61850, S7, and more than thirty others in total.

2.2.5 WEB Management System

Provides a visual graphical management interface through which users can perform all configuration operations via a browser without requiring professional command-line knowledge.

  • B/S architecture supporting mainstream browsers including Chrome, Edge, and Firefox;
  • Interface designed in Chinese with clear functional zoning and intuitive operating flows;
  • Dashboard overview with real-time display of traffic, threats, and system status;
  • Configuration wizard guiding new users through basic deployment step by step.

2.2.6 Logging and Audit Module

Responsible for recording all system events, security events, and traffic data, generating statistical reports and satisfying compliance audit requirements.

  • Log categories: System logs, configuration logs, virus logs, traffic logs, alarm logs, and administrator operation logs;
  • Log query: Supports multi-dimensional combined queries, fuzzy queries, and time-range queries;
  • Report generation: Supports daily, weekly, monthly, and custom reports, exportable in PDF/Excel formats;
  • Log export: Supports exporting logs via Syslog, FTP, email, and other methods, with integration to third-party log platforms.

2.2.7 Alarm and Linkage Module

Responsible for alarm notification of security events and coordinated handling across multiple devices.

  • Alarm methods: Local audible/visual alarm, WEB pop-up alarm, email alarm, SMS alarm, Syslog alarm;
  • Alarm grading: Classified by severity into four levels — critical, major, general, and informational;
  • Linkage functions: Supports linkage with firewalls, IPS, and endpoint security management platforms — upon virus detection, infected hosts are automatically isolated;
  • Supports integration with SOC security operations platforms for inclusion in a unified security operations system.

2.2.8 High-Availability Redundancy Module

Ensures continuity of the device and business operations, including:

  • Bypass management module: Controls hardware Bypass switching, supporting manual testing and status monitoring;
  • Dual-machine hot standby (HA) module: Supports active/standby mode and active/active mode, with automatic configuration synchronization and automatic fault switchover;
  • Link aggregation module: Supports LACP static aggregation to increase link bandwidth and reliability;
  • Load balancing module: Supports traffic load sharing in multi-egress scenarios.

Chapter 3: Product Classification

The LA-AV Series Antivirus Gateway covers the full performance range from 100 Mbps to 100 Gbps, adapted to protection needs across different scales, industries, and scenarios. Classification can be performed from multiple dimensions.

3.1 Classification by Processing Performance

This is the most fundamental classification method, corresponding to user networks of different scales based on device throughput and processing capability.

3.1.1 Entry-Level Antivirus Gateway (LA-AV100 Series)

Attribute Specification
Performance positioning 100 Mbps–1 Gbps entry level, suitable for small networks
Typical throughput 100 Mbps–500 Mbps with full-feature virus scanning enabled
Concurrent connections 100,000–500,000
Applicable user scale 50–200 terminals
Interface configuration 4–6 Gigabit copper ports, 2 Bypass groups
Typical application scenarios Small enterprises, branch offices, retail stores, small offices
Core characteristics Compact size, low power consumption, affordable pricing, simple deployment, meeting basic virus protection and compliance needs

3.1.2 Standard Enterprise Antivirus Gateway (LA-AV500/2000 Series)

Attribute Specification
Performance positioning Gigabit mid-range, suitable for medium enterprises and government/enterprise entities
Typical throughput 1 Gbps–5 Gbps with full-feature virus scanning enabled
Concurrent connections 1,000,000–3,000,000
Applicable user scale 200–2,000 terminals
Interface configuration 8–16 Gigabit copper ports + 2–4 Gigabit optical ports, 4–6 Bypass groups
Typical application scenarios Medium enterprises, government institutions, district/county-level agencies, schools, hospitals
Core characteristics Balanced performance, comprehensive functionality, high reliability, supports dual power supplies and HA dual-machine hot standby, meets Level 3 MLPS requirements

3.1.3 High-End Data Center Antivirus Gateway (LA-AV5000/10000 Series)

Attribute Specification
Performance positioning 10-Gigabit high-end, suitable for large networks and data centers
Typical throughput 8 Gbps–40 Gbps with full-feature virus scanning enabled
Concurrent connections 5,000,000–15,000,000
Applicable user scale 2,000–10,000 terminals
Interface configuration 8–16 Gigabit copper ports + 4–8 10-Gigabit optical ports, 8 or more Bypass groups, 40G interface expansion supported
Typical application scenarios Large enterprise headquarters, provincial/municipal government agencies, universities, top-tier hospitals, data centers
Core characteristics High performance, high reliability, high scalability, supports virtualization and multi-tenancy, meeting complex deployment needs of large networks

3.1.4 Carrier-Grade Antivirus Gateway (LA-AV40000/100000 Series)

Attribute Specification
Performance positioning 40 Gbps–100 Gbps, carriers and ultra-large networks
Typical throughput 40 Gbps–100 Gbps with full-feature virus scanning enabled
Concurrent connections 20,000,000–50,000,000
Applicable user scale 10,000+ terminals or carrier backbone nodes
Interface configuration 40G/100G high-speed optical interfaces, clustered deployment
Typical application scenarios Carrier metropolitan area networks, IDC facilities, ultra-large enterprise groups
Core characteristics Carrier-grade reliability, clustered deployment, large-bandwidth processing capability, carrier-grade operations management

3.2 Classification by Hardware Form Factor

3.2.1 Rack-Mounted Antivirus Gateway

The most mainstream form factor, standard 19-inch rack mounting, 1U–4U height.

  • Advantages: Standardized installation, good heat dissipation, easy cable management, suitable for data center deployment.
  • Applicable scenarios: Standard equipment rooms, data centers, core node deployment.
  • The main models across the LA-AV series are rack-mounted.

3.2.2 Desktop Antivirus Gateway

Compact design with small footprint, can be placed directly on a desktop or in a weak-current enclosure.

  • Advantages: Small size, light weight, no rack required, low noise.
  • Applicable scenarios: Small offices, retail stores, branch offices, and scenarios without a dedicated equipment room.
  • Representative model: LA-AV100-D Desktop Edition.

3.2.3 Box-Type Compact Antivirus Gateway

Industrial-grade compact design with DIN-rail or wall-mount installation, adapted to industrial field environments.

  • Advantages: Rugged construction, dust-proof and vibration-resistant, wide-temperature operation, supports DC power supply.
  • Applicable scenarios: Industrial workshops, substations, outdoor cabinets, rail transit.
  • Representative model: LA-AV Industrial Control Series.

3.2.4 Modular Blade Antivirus Gateway

Exists in the form of a service line card that can be inserted into a core switch or unified security gateway chassis.

  • Advantages: Saves rack space, unified management, shared power supply and fans.
  • Applicable scenarios: Large core equipment rooms, unified security architecture deployment.
  • Representative model: LA-AV-M Series line cards.

3.3 Classification by Deployment Mode

3.3.1 Inline (Series) Antivirus Gateway

Business traffic passes directly through the device, is scanned and forwarded in real time, and malicious traffic can be directly blocked.

  • Advantages: Real-time interception, effective protection, flexible deployment.
  • Disadvantages: Device failure may affect the network (requires Bypass protection).
  • Applicable scenarios: Internet egress, zone boundaries, and other locations requiring real-time blocking.
  • All LA-AV series models support inline deployment.

3.3.2 Bypass (Out-of-Path) Antivirus Gateway

Performs detection via mirrored traffic without being connected in series to the business link — detection only, no blocking.

  • Advantages: Zero impact on the network, zero risk, simple deployment.
  • Disadvantages: Cannot block in real time; requires linkage with other devices for handling.
  • Applicable scenarios: Traffic auditing, threat monitoring, and core links where business interruption is not permitted.
  • All LA-AV series models support bypass deployment.

3.3.3 Hybrid Antivirus Gateway

Supports both inline and bypass deployment simultaneously, allowing configuration of some interfaces in inline mode and others in bypass mode, flexibly adapting to complex networks.

  • Advantages: Flexible deployment, one device meeting multiple needs.
  • Applicable scenarios: Multi-zone, multi-link complex network environments.

3.4 Classification by Application Industry

3.4.1 General Government/Enterprise Antivirus Gateway

Standard general-purpose version supporting general Internet protocols, meeting the basic needs of most industries.

  • Adapted scenarios: Government, enterprise, education, healthcare, and other general scenarios.
  • Core functions: General virus protection, protocol scanning, log auditing, compliance reporting.

3.4.2 Industrial Control Specialized Antivirus Gateway

Customized for industrial control scenarios, supporting deep parsing of industrial control protocols and adapted to harsh industrial environments.

  • Special support: Whitelisting and virus detection for industrial control protocols including Modbus, S7, IEC 104, and IEC 61850.
  • Hardware characteristics: Wide temperature range (-40 °C to +70 °C), dust-proof, vibration-resistant, DC power supply, fanless option.
  • Adapted scenarios: Smart manufacturing, electric power, rail transit, petrochemical, municipal industrial control systems.
  • Representative model: LA-AV-ICS Series.

3.4.3 Financial-Grade Antivirus Gateway

Customized for the high-security, high-compliance requirements of the financial industry, with enhanced auditing and encrypted-traffic detection capabilities.

  • Special enhancements: National cryptographic algorithm (SM series) support, detailed operation auditing, two-factor authentication, financial industry compliance reporting.
  • Reliability: 99.999% availability requirement, fully redundant design.
  • Adapted scenarios: Banks, securities, insurance, payment institutions.

3.4.4 MLPS Compliance Specialized Antivirus Gateway

Specifically optimized for Classified Protection evaluation, with built-in MLPS compliance checklist tools and one-click report generation.

  • Built-in MLPS 2.0 Level 3/Level 4 compliance checklist;
  • One-click generation of security policies, logs, and report documents required for MLPS evaluation;
  • Provides MLPS rectification recommendations and configuration templates.
  • Adapted scenarios: MLPS evaluation entities, government/enterprise customers requiring rapid MLPS compliance.

3.5 Classification by Function Integration

3.5.1 Dedicated Antivirus Gateway (Pure)

Focused on core virus detection functionality without integrating redundant firewall, IPS, or other functions, providing optimal detection performance and depth.

  • Advantages: High professionalism, strong detection capability, minimal performance overhead, excellent cost-effectiveness.
  • Applicable scenarios: Scenarios where a firewall/IPS already exists and dedicated virus protection needs to be supplemented; high-security-grade networks.
  • The LA-AV standard series are all dedicated antivirus gateways.

3.5.2 Converged Antivirus Gateway

Integrates basic firewall, access control, intrusion prevention, Internet behavior management, and other functions into an all-in-one security device.

  • Advantages: Comprehensive functionality, one device solving multiple problems, saving cost and rack space.
  • Applicable scenarios: Small networks, budget-constrained scenarios, and scenarios wishing to simplify operations.
  • Representative model: LA-AV-U Converged Series.

Chapter 4: Product Checklist

4.1 Standard Packing List

Upon receiving the device, users should first check the contents against the following list. If anything is missing or damaged, please contact sales or technical support promptly.

4.1.1 Device Host

  • Antivirus Gateway host: 1 unit
  • The host serial number is affixed to the rear panel of the device and on the warranty card. It is the unique identifier of the device — please keep it safe.

4.1.2 Power Accessories

  • AC power cable: 1 (single power supply models) / 2 (redundant power supply models)
  • Power cable specification: 10 A, 250 V~, three-pin national standard plug, 1.8 m length
  • DC models come with the corresponding DC power cables.

4.1.3 Installation Accessories

  • Rack-mount mounting ears: 1 pair (left and right)
  • M4 mounting screws: 8 (for securing ears to chassis)
  • M5 rack fixing screws: 4 (for securing device into rack; provided with the rack on select models)
  • Rubber feet: 4 (for desktop installation)

4.1.4 Connection Cables

  • Gigabit network cable: 1 (for management port debugging, 1.5 m length)
  • Console debug cable: 1 (RJ45 to RS232 serial cable, 1.5 m length; USB-to-Console cable on select models)

4.1.5 Documentation

  • *Antivirus Gateway Quick Installation Guide*: 1 copy
  • *Product Certificate of Conformity*: 1 copy
  • *Warranty Card*: 1 copy
  • MLPS compliance materials package (electronic version, stored on USB drive)
  • This manual is available in electronic format; the latest version can be downloaded from the official website https://gdlain.com

4.2 Optional Accessories List

The following accessories must be ordered separately. Users may select them based on actual needs.

4.2.1 Hardware Optional Accessories

Accessory Description
Redundant power supply module Upgrades single power supply models to 1+1 redundant power for improved reliability
Optical module kits SFP Gigabit optical modules (single-mode/multi-mode), SFP+ 10-Gigabit optical modules
Expansion interface cards Additional copper port cards and optical port cards to expand interface count
Rack-mount rails L-type rails or sliding rails for convenient device drawer-style maintenance
Industrial-grade DC power module -48 V/24 V DC power supply, suitable for industrial and telecommunications scenarios
Fan module Spare hot-swappable fan modules

4.2.2 Software and Service Optional Accessories

Accessory Description
Virus signature database upgrade license 1-year/3-year/5-year upgrade service license
Cloud threat intelligence subscription service Real-time threat intelligence, APT intelligence, malicious URL database subscription
Sandbox detection service license Advanced sandbox dynamic detection functionality license
AI detection engine upgrade license Advanced version of the deep learning AI engine license
Extended warranty service Extends the full-unit warranty period, providing 7×24 on-site service
MLPS compliance consulting service Professional MLPS consulting and evaluation assistance service
Centralized management platform license Software license for unified management of multiple devices

4.3 Accompanying Documentation Description

4.3.1 Quick Installation Guide

A condensed installation guide containing quick steps for wiring, initialization, and basic configuration, suitable for experienced engineers to deploy quickly.

4.3.2 Product Certificate of Conformity

Certifies that the product passed factory inspection, containing the product model, serial number, date of manufacture, inspection stamp, and other information.

4.3.3 Warranty Card

Records product warranty information. It takes effect after the user fills in the information and it is stamped. It is the voucher for warranty service — please complete it in full and keep it safe.

4.3.4 Compliance Test Report

Contains copies of third-party product test reports, sales license copies, copyright certificate copies, and other compliance materials, used for project acceptance and MLPS evaluation.

Chapter 5: Product Working Principle

5.1 Overall Workflow Overview

The core working logic of the Antivirus Gateway is “traffic ingress → protocol parsing → file reconstruction → virus detection → threat disposition → traffic forwarding/discarding.” The complete process is divided into seven stages:

Stage Description
1. Traffic ingress Business traffic enters the device through the ingress interface; the network processor performs basic packet parsing and session management.
2. Protocol identification The protocol parsing engine identifies the application protocol type carried by the traffic (HTTP/FTP/email, etc.).
3. Session reconstruction Tracks TCP session state and reassembles scattered data packets into complete file streams.
4. Preprocessing Performs preprocessing on files including decompression, unpacking, and format identification.
5. Virus detection Multiple detection engines scan and inspect files in parallel.
6. Result determination Synthesizes detection results from multiple engines to determine whether a file is malicious code.
7. Disposition and forwarding Normal files are allowed through and forwarded; malicious files are subject to disposition actions including blocking, quarantine, and alarm.

The entire process is completed through hardware–software coordination, with most foundational processing executed by hardware acceleration engines to ensure low latency under high traffic load.

5.2 Network Traffic Access and Forwarding Principles

The antivirus gateway supports three mainstream deployment modes, each with different traffic forwarding principles.

5.2.1 Transparent Bridge Mode Forwarding Principles

Transparent bridge mode is the most commonly used deployment mode. The device operates at the data link layer, functioning as an “intelligent network bridge” with virus scanning capabilities.

Operating Principles:

  • The device configures a pair of service interfaces as a bridge group; both interfaces belong to the same broadcast domain, without independent IP addresses (or with management IP only);
  • Traffic enters from the bridge ingress port, and the device directly forwards layer-2 data frames without any modification to IP packets;
  • During forwarding, the device performs deep packet inspection and virus scanning internally;
  • After scanning is complete, normal data frames are sent out from the bridge egress port into the downstream network.

Core Features:

  • Fully transparent to user networks — no modification to upstream/downstream device IP configuration or routing configuration required; plug-and-play;
  • Does not alter network topology, introduces no new network nodes, minimizing points of failure;
  • Supports Bypass — when the device fails, physical passthrough is activated and the network remains completely unaffected;
  • Does not support layer-3 functions such as NAT or routing; suitable for pure protection scenarios.

5.2.2 Routing Mode Forwarding Principles

In routing mode, the device operates at the network layer, functioning as a security router with virus protection capabilities.

Operating Principles:

  • Each service interface is configured with an independent IP address, belonging to different network segments;
  • The device maintains a routing table and performs routing forwarding based on destination IP addresses;
  • Traffic forwarded across network segments passes through the device’s virus scanning engine for detection;
  • Supports static routing, dynamic routing (OSPF/BGP), NAT address translation, and other functions.

Core Features:

  • Can replace an edge router or firewall, simultaneously implementing routing functions and virus protection;
  • Supports NAT, VPN, access control, and other extended functions;
  • Requires modification of network topology and IP planning; deployment complexity is higher than transparent mode;
  • Suitable for small network egress integrated deployment scenarios.

5.2.3 Bypass Mirror Mode Forwarding Principles

In bypass mode, the device is not inserted inline into the service link; it obtains traffic copies through a switch mirror port for detection.

Operating Principles:

  • The core switch mirrors the link traffic to be inspected to the mirror port;
  • The mirror interface of the antivirus gateway receives mirrored traffic — receive-only, no transmission;
  • The device parses and performs virus detection on the mirrored traffic, generating detection logs and alerts;
  • When a virus threat is detected, blocking commands are issued to the switch/firewall through linkage interfaces, or administrators are notified for manual handling.

Core Features:

  • Completely non-intrusive to the service link — device failure has zero impact on the business network; zero risk;
  • Cannot directly block threats; requires linkage with other devices or manual handling;
  • Suitable for core business links and production systems where interruption is not permitted;
  • Applicable to threat monitoring, audit analysis, and situational awareness scenarios.

5.3 Protocol Deep Parsing Principles

Protocol parsing is the prerequisite for virus detection. Only by correctly identifying protocols and reassembling complete files can accurate virus scanning be performed. The LA-AV series adopts “stateful protocol parsing + dynamic port identification” technology.

5.3.1 HTTP Protocol Parsing Principles

HTTP is the primary carrier for virus propagation — web downloads, web uploads, and web page-based malware (malvertising/exploit kits) all transmit via the HTTP protocol.

Parsing Process:

  • Identify HTTP request and response messages, parse request methods (GET/POST, etc.), URLs, and response status codes;
  • Identify the Content-Type field to determine content type;
  • Reassemble HTTP entity content based on TCP sessions, restoring complete downloaded/uploaded files;
  • Handle special formats including HTTP chunked transfer, resumable downloads, and compression encoding (gzip/deflate);
  • Deliver reassembled files to the detection engine for scanning.

5.3.2 FTP Protocol Parsing Principles

FTP is a commonly used file transfer protocol, comprising a control connection and data connection, making parsing more complex.

Parsing Process:

  • Track the FTP control connection (port 21), parse PORT/PASV commands to obtain the data connection port number;
  • Dynamically identify data connections and associate them with corresponding control sessions;
  • Reassemble file content in data connections, distinguishing upload and download directions;
  • Supports both active mode and passive mode FTP parsing.

5.3.3 SMTP/POP3/IMAP Email Protocol Parsing Principles

Email attachments are one of the core channels for virus propagation, especially phishing emails carrying ransomware.

SMTP Outbound Email Parsing:

  • Parse SMTP commands to identify email sending sessions;
  • Parse email headers (sender, recipient, subject);
  • Decode MIME multipart email bodies and extract attachment files;
  • Perform virus scanning on attachments, supporting nested email parsing.

POP3/IMAP Inbound Email Parsing:

  • Track email receiving sessions and reassemble complete email content;
  • Decode email encodings (Base64, UUEncode, etc.) and extract attachments;
  • Scan attachments and email body scripts.

5.3.4 SMB File Sharing Protocol Parsing Principles

SMB is the primary protocol for intranet file sharing and an important vector for lateral virus propagation within the internal network — for example, the EternalBlue vulnerability spreads via SMB.

Parsing Process:

  • Identify SMB protocol sessions and parse SMB commands (read file, write file);
  • Reassemble complete content of shared file transfers;
  • Perform virus scanning on transferred files to block lateral intranet propagation;
  • Supports full-version SMB v1/v2/v3 parsing.

5.3.5 Encrypted Traffic Decryption and Detection Principles

With the widespread adoption of HTTPS, a large amount of malware now propagates through encrypted traffic, which traditional gateways cannot detect. The LA-AV series supports SSL/TLS decryption detection.

Operating Principles:

  • The device acts as a man-in-the-middle (MITM), establishing separate SSL connections between client and server;
  • The client establishes an SSL connection with the gateway, with the gateway simulating the server identity;
  • The gateway establishes an SSL connection with the real server, simulating the client identity;
  • The gateway decrypts traffic in the middle, performs virus scanning, then re-encrypts and forwards;
  • The gateway’s root certificate must be imported on clients to avoid certificate warnings.

Security Notes:

  • Decryption is performed only in the device’s local memory; decrypted plaintext data is never retained;
  • Supports configurable decryption whitelist — sensitive sites such as banking and payment platforms can skip decryption;
  • Compliant with the “Cybersecurity Law of the People’s Republic of China”; used solely for internal enterprise security protection.

5.4 Core Virus Detection Principles

5.4.1 Signature Matching Detection Principles

Signature detection is the most classic and reliable detection technology. The principle involves extracting unique signature fragments from virus files, building a signature database, and comparing files against these signatures during scanning.

Technical Details:

  • Signature Extraction: Extract unique byte sequences from critical code segments and data segments of the virus body, ensuring normal files do not contain these sequences;
  • Signature Database Construction: Index tens of millions of signatures using hash tables, Aho-Corasick automata, and other data structures for high-speed matching;
  • Scanning Process: After file preprocessing, segments are matched against the signature database sequentially; a signature hit indicates virus detection;
  • Multi-segment Signatures: Complex viruses use multi-segment signature combination matching to reduce false positive rates.

Advantages and Disadvantages:

  • Advantages: Accurate detection, extremely low false positive rate, high speed, mature technology;
  • Disadvantages: Can only detect known viruses; cannot detect newly emerging unknown viruses.

5.4.2 Heuristic Scanning Detection Principles

Heuristic detection is based on the pattern that “viruses typically exhibit similar behavior and structural characteristics,” using rules to judge whether a file is suspicious without relying on a signature database.

Static Heuristic Detection:

  • Analyze file structure: abnormal section sizes, incorrect entry points, multiple layers of packing;
  • Analyze code characteristics: API call sequences commonly used by viruses, abnormal jumps;
  • Analyze file attributes: hidden attributes, system attributes, abnormal file sizes.

Dynamic Heuristic Detection:

  • Simulate execution of the first N instructions of a file in a sandbox environment;
  • Observe whether typical virus behaviors occur, such as self-replication, system file modification, or API hooking;
  • Score based on the number of suspicious behaviors; if the threshold is exceeded, the file is judged as a virus.

Advantages and Disadvantages:

  • Advantages: Can detect unknown mutated viruses without requiring a signature database;
  • Disadvantages: Certain false positive rate exists; limited detection rate for complex viruses.

5.4.3 Behavior Analysis Detection Principles

Behavior analysis does not focus on the file itself, but rather on the network behavior and system behavior exhibited after the file executes, identifying malware through behavior patterns.

Network Behavior Detection:

  • Abnormal outbound connections: connecting to unfamiliar overseas IPs, high-frequency connections to C&C servers;
  • Port scanning: batch port scanning of the internal network, attempting lateral penetration;
  • Abnormal traffic: large volumes of outbound data (data theft), high-frequency DNS requests (tunnel communication);
  • Mining behavior: connecting to mining pool addresses, specific algorithm communication patterns.

Host Behavior Detection:

  • Ransomware behavior: batch file encryption, modifying file extensions, deleting backups;
  • Persistence behavior: modifying the registry, creating scheduled tasks, injecting into system processes;
  • Privilege escalation behavior: exploiting vulnerabilities to elevate system privileges.

Behavior analysis is particularly effective at detecting malware with clear objectives such as mining, ransomware, and remote access trojans.

5.4.4 Sandbox Dynamic Detection Principles

A sandbox is an isolated virtual execution environment that runs suspicious files in real conditions to observe all their behaviors and determine whether they are malicious.

Workflow:

  • The gateway submits suspicious files to the sandbox system (local or cloud);
  • The sandbox creates an isolated virtual machine environment simulating a real operating system;
  • The suspicious file is executed within the virtual machine, with full monitoring of file operations, registry modifications, network behavior, process creation, and all other actions;
  • After execution completes, a comprehensive determination is made based on behavior rules and AI models;
  • Detection results are returned to the gateway, updating detection rules.

Advantages and Disadvantages:

  • Advantages: Extremely high detection accuracy, effectively identifying unknown viruses and zero-day attacks;
  • Disadvantages: Detection takes considerable time (tens of seconds to minutes), cannot provide real-time blocking; typically used as a supplementary detection method.

5.4.5 AI Artificial Intelligence Detection Principles

AI detection is based on deep learning models trained on massive sample sets, automatically learning deep-seated virus features and overcoming the limitations of traditional rules.

Technical Principles:

  • Sample Training: Train deep neural networks using tens of millions of malicious samples and normal file samples;
  • Automatic Feature Extraction: The model automatically learns byte-level, structural-level, and semantic-level features of viruses without manual rule definition;
  • Inference Detection: During scanning, files are input into the model, which outputs a malicious probability; exceeding the threshold classifies the file as a virus;
  • Model Iteration: The cloud continuously optimizes the model with new samples and periodically updates local devices.

The LA-AV employs a dual AI engine combining a static file CNN model and a traffic behavior Transformer model, improving unknown virus detection rates by more than 30%.

5.4.6 Compressed Archive and Packed File Unpacking Detection Principles

Virus authors often package viruses in compressed archives or apply packing protection to evade detection. The LA-AV series supports deep unpacking and decompression.

Compressed Archive Processing:

  • Supports dozens of compression formats including ZIP, RAR, 7Z, GZIP, TAR;
  • Supports recursive decompression of multi-layer nested archives, up to 20 nesting levels;
  • Supports password-protected archive detection, attempting common weak passwords for decompression;
  • Configurable maximum scan archive size to prevent oversized packages from impacting performance.

Packing Processing:

  • Supports automatic unpacking of over 100 common packing tools including UPX, ASPack, PECompact;
  • Uses heuristic identification and generic unpacking technology for unknown packers;
  • Effectively detects viruses hidden in packed files and multi-layer packed files.

5.5 Threat Disposal Principles

When malicious code is detected, the gateway executes corresponding actions according to the configured disposal policy.

5.5.1 Real-time Blocking Principles

In inline deployment mode, the gateway directly discards malicious packets, interrupting the transmission connection.

  • HTTP download scenario: Returns an interception page notifying the user that the file contains a virus and has been blocked;
  • FTP transfer scenario: Interrupts the data connection and returns a transfer failure;
  • Email scenario: Refuses to receive/send virus-laden emails, returns a bounce message, or removes attachments;
  • Intranet transfer scenario: Directly blocks the connection, recording source/destination IPs and virus information.

Blocking actions are executed in real time within the traffic forwarding path with microsecond-level latency; virus files cannot enter the internal network.

5.5.2 File Quarantine Principles

For scenarios where direct blocking is not possible, or when virus files need to be retained as evidence, the gateway can quarantine files to a dedicated quarantine area.

  • The quarantine area is encrypted to prevent virus escape;
  • Administrators can view quarantined file details and manually restore false-positive files;
  • Quarantined files can be submitted to the cloud for further analysis;
  • Supports automatic cleanup of expired quarantined files.

5.5.3 Alert Reporting Principles

Upon virus detection, alerts are immediately triggered to notify administrators.

  • Local alert: Device alert indicator lights up; WEB interface displays alert pop-ups;
  • Email alert: Alert emails sent to designated administrator mailboxes, including virus details, source/destination IPs, time, and other information;
  • SMS alert: Interfaces with SMS gateway to send SMS notifications (optional);
  • Syslog alert: Sends alert logs to third-party log platforms or SOC platforms.

5.5.4 Linkage Blocking Principles

In bypass deployment mode, the gateway cannot block traffic directly and must rely on linkage with other devices for disposal.

  • Firewall linkage: Issue blacklisted IP/domain to the firewall for blocking infected hosts;
  • Switch linkage: Issue ACL rules to the switch to isolate infected ports;
  • Endpoint security platform linkage: Notify endpoint antivirus software to perform full-system scanning on infected hosts;
  • RESTful API support for user-defined linkage logic.

5.6 Hardware Bypass Operating Principles

Bypass is the core reliability guarantee of the antivirus gateway. The LA-AV series employs a pure hardware Bypass mechanism that does not rely on software at all.

5.6.1 Power Failure Bypass Trigger Principles

  • During normal device power supply, the relay remains in the “device connected” state, and traffic passes through the device for scanning;
  • When the device loses power, the relay loses power and, under spring action, automatically switches to the “passthrough” state — ingress and egress ports are physically connected directly, and traffic bypasses the device for direct transmission;
  • When power is restored, the relay automatically engages, switching back to normal scanning state. The switchover process has no packet loss or extremely brief packet loss.

5.6.2 System Failure Bypass Trigger Principles

  • The device incorporates a hardware watchdog chip that periodically sends heartbeat checks to the system;
  • When the system is running normally, it continuously replies to watchdog heartbeats;
  • When the system crashes, processes hang, or a kernel panic occurs, heartbeats cannot be replied to; the watchdog triggers hardware Bypass after timeout, switching to passthrough state;
  • When the system recovers to normal, it automatically switches back to working mode.

5.6.3 Manual Bypass Switch Principles

Administrators can manually trigger Bypass through the WEB interface or CLI commands for device upgrades, reboots, and maintenance scenarios, ensuring business continuity during maintenance.

  • Supports independent switching of individual Bypass interface groups;
  • Supports one-click global Bypass switching;
  • Switch status is reflected in real time via indicator lights.

5.7 Signature Database Upgrade Principles

The virus signature database requires continuous updates to address the constant emergence of new viruses. The LA-AV supports multiple upgrade methods.

5.7.1 Online Automatic Upgrade Principles

  • The device periodically (configurable, default every hour) connects to the LAIN cloud upgrade server;
  • Compares the local signature database version with the latest cloud version;
  • If updates exist, downloads an incremental upgrade package — only downloading new signatures to save bandwidth;
  • After download, verifies the integrity and digital signature of the upgrade package to prevent tampering;
  • After verification, hot-loads into the detection engine; the upgrade process does not interrupt business and does not require device reboot;
  • Generates upgrade logs recording upgrade time, version number, and signature count changes.

5.7.2 Local Manual Upgrade Principles

For internal network environments without internet connectivity, manual upgrade is supported.

  • Download the latest signature database upgrade package from the LAIN official website;
  • Upload the upgrade package to the device through the WEB management interface;
  • The device verifies the legality of the upgrade package and executes the upgrade;
  • Results are displayed after upgrade completion; current version can be viewed.

5.7.3 Incremental Upgrade and Full Upgrade Mechanisms

  • Incremental upgrade: Daily updates use incremental mode, downloading only new and modified signatures — small size, fast speed, minimal network impact;
  • Full upgrade: For major version updates or when the device signature database is corrupted, the complete signature database is downloaded to ensure signature integrity;
  • The device prioritizes incremental upgrades by default; after multiple consecutive incremental upgrades, a full upgrade is automatically executed to avoid cumulative signature errors.

Chapter 6 Product Technical Specifications

6.1 Hardware Technical Specifications

6.1.1 Chassis Specifications

Parameter LA-AV100 LA-AV500 LA-AV2000 LA-AV5000 LA-AV10000
Chassis Height 1U 1U 2U 2U 4U
Rack Width Standard 19-inch Standard 19-inch Standard 19-inch Standard 19-inch Standard 19-inch
Chassis Depth 300mm 350mm 450mm 500mm 650mm
Material SECC Galvanized Steel SECC Galvanized Steel SECC Galvanized Steel SECC Galvanized Steel SECC Galvanized Steel + Aluminum Alloy Panel
Weight 5kg 8kg 12kg 18kg 35kg

6.1.2 Processor Specifications

Parameter LA-AV100 LA-AV500 LA-AV2000 LA-AV5000 LA-AV10000
Main CPU Model Domestic 4-core Processor Domestic 8-core Processor Domestic 16-core Processor Domestic 32-core Processor Domestic 64-core Processor
Main Clock Frequency 2.0GHz 2.2GHz 2.5GHz 2.7GHz 3.0GHz
Network Co-processor Gigabit NP Chip Gigabit NP Chip 10G NP Chip 10G NP Chip 40G Multi-core NP
Hardware Acceleration Engine Basic Regex Acceleration Basic Regex Acceleration Advanced Content Acceleration Advanced Content Acceleration Flagship Content Acceleration

6.1.3 Memory and Storage Specifications

Parameter LA-AV100 LA-AV500 LA-AV2000 LA-AV5000 LA-AV10000
Standard Memory 8GB DDR4 ECC 16GB DDR4 ECC 32GB DDR4 ECC 64GB DDR4 ECC 128GB DDR4 ECC
Maximum Memory 16GB 32GB 64GB 128GB 256GB
System Disk 64GB SSD 128GB SSD 256GB SSD 512GB SSD 1TB NVMe SSD
Log Disk None 500GB SSD 1TB SSD 2TB SSD 4TB SSD
Storage Expansion None 1 SATA Slot 2 SATA Slots 4 SATA Slots 8 SATA Slots

6.1.4 Interface Specifications

Parameter LA-AV100 LA-AV500 LA-AV2000 LA-AV5000 LA-AV10000
Gigabit Copper Ports 6 8 16 16 16
Gigabit SFP Fiber Ports 2 4 8 8 8
10G SFP+ Fiber Ports None None 2 4 8
40G QSFP+ Fiber Ports None None None None 2
Bypass Group Count 2 groups 4 groups 6 groups 8 groups 10 groups
Management Copper Ports 1 Gigabit 1 Gigabit 1 Gigabit 2 Gigabit 2 Gigabit
Console Port 1 RJ45 1 RJ45 1 RJ45 1 RJ45 2 RJ45
USB Interfaces 2 USB3.0 2 USB3.0 2 USB3.0 4 USB3.0 4 USB3.0

6.1.5 Power Supply Specifications

Parameter LA-AV100 LA-AV500 LA-AV2000 LA-AV5000 LA-AV10000
Power Configuration Single AC Power Single AC Power (Redundant optional) 1+1 Redundant AC 1+1 Redundant AC 2+2 Redundant AC
Input Voltage 100-240V~ 50/60Hz 100-240V~ 50/60Hz 100-240V~ 50/60Hz 100-240V~ 50/60Hz 100-240V~ 50/60Hz
Rated Power 150W 300W 500W 800W 1500W
Power Efficiency ≥85% ≥88% ≥90% Platinum ≥92% Platinum ≥94% Titanium
Hot-swap Support No No Yes Yes Yes
DC Power Optional No Yes Yes Yes Yes

6.1.6 Cooling and Environmental Specifications

Parameter General Model Specifications Industrial Model Specifications
Operating Temperature 0℃~45℃ -40℃~70℃
Storage Temperature -20℃~70℃ -40℃~85℃
Operating Humidity 10%~90% Non-condensing 5%~95% Non-condensing
Cooling Method Intelligent Temperature-controlled Fans Fanless / Fan Optional
Noise ≤45dB (Normal Temperature) ≤55dB (Fan Version)
Dust Protection Rating IP30 IP50
Vibration Resistance Compliant with GB/T 9813 Standard Compliant with GB/T 2423 Industrial Standard

6.1.7 Reliability Specifications

  • Mean Time Between Failures (MTBF): ≥100,000 hours
  • Power Supply MTBF: ≥200,000 hours
  • Bypass Switch Time: ≤10ms
  • System Availability: ≥99.99% (≥99.999% in redundant configuration)

6.2 Software Functional Specifications

6.2.1 Supported Protocol List

Protocol Category Supported Protocols
Web Protocols HTTP, HTTPS, HTTP2, WebSocket
File Transfer Protocols FTP, SFTP, TFTP, SCP
Email Protocols SMTP, POP3, IMAP, Exchange
File Sharing Protocols SMB/CIFS v1/v2/v3, NFS
Database Protocols MySQL, SQL Server, Oracle (Basic Detection)
Industrial Control Protocols Modbus TCP, S7, IEC104, IEC61850, DNP3
Other Protocols Telnet, SSH, RDP, DNS

6.2.2 Virus Detection Capability Specifications

  • Known Virus Detection Rate: ≥99.8% (based on internationally authoritative virus sample database testing)
  • Unknown Virus Detection Rate: ≥85% (combined AI + heuristic + sandbox detection)
  • False Positive Rate: ≤0.01%
  • Supported Virus Types: Viruses, Trojans, Worms, Ransomware, Mining Programs, Spyware, Adware, Backdoors, Rootkits, Macro Viruses, Script Viruses, etc.
  • Supported Compression Formats: ZIP, RAR, 7Z, CAB, ARJ, GZIP, BZIP2, and 30+ more
  • Maximum Supported Compression Layers: 20 layers
  • Supported Packer Types: Automatic unpacking of 100+ common packing tools

6.2.3 Signature Database Specifications

  • Base Virus Signature Count: ≥20 million entries
  • Ransomware Specialized Signatures: ≥500,000 entries
  • Mining Program Signatures: ≥200,000 entries
  • Malicious URL Count: ≥100 million entries
  • Signature Database Update Frequency: Base database at least once daily, specialized databases updated hourly, threat intelligence updated in real time
  • Signature Database Upgrade Methods: Online automatic upgrade, local manual upgrade, centralized management platform unified push

6.2.4 Management Function Specifications

  • Management Methods: WEB graphical management, CLI command line, SSH remote management, Console local management, centralized management platform
  • Administrator Roles: Super Administrator, System Administrator, Security Administrator, Audit Administrator (Separation of Powers)
  • Authentication Methods: Local password authentication, Radius authentication, LDAP authentication, two-factor authentication
  • Configuration Management: Configuration backup/restore, configuration export/import, configuration rollback, configuration comparison
  • System Upgrade: System firmware upgrade, signature database upgrade, engine upgrade; supports hot upgrade without business interruption

6.2.5 Log and Audit Specifications

  • Log Types: System logs, security logs, traffic logs, configuration logs, operation logs, alert logs
  • Log Storage Duration: 6 months by default; extendable for longer storage
  • Log Query: Supports multi-dimensional queries by time, source IP, destination IP, virus type, protocol, etc.
  • Report Function: 100+ built-in report templates, supports custom reports, supports PDF/Excel export
  • Log Export: Supports Syslog (UDP/TCP), FTP, email, Kafka, and other export methods
  • Log Integrity: Supports log digital signatures to prevent log tampering

6.3 Performance Indicator Specifications

Test conditions: Standard ambient temperature of 25℃, all virus detection functions enabled, HTTP protocol, average file size of 1MB.

Performance Indicator LA-AV100 LA-AV500 LA-AV2000 LA-AV5000 LA-AV10000
Maximum Throughput (Full-feature Scanning) 500Mbps 2Gbps 5Gbps 10Gbps 40Gbps
Maximum Concurrent Connections 500,000 1.5 million 3 million 8 million 20 million
New Connections Per Second (TPS) 5,000 20,000 50,000 150,000 500,000
Virus Scan Latency <1ms <1ms <1.5ms <2ms <3ms
Maximum Supported Users 200 800 2,000 5,000 20,000
Bypass Switch Time <10ms <10ms <10ms <10ms <10ms

Note: Performance data represents laboratory ideal environment test values. Actual performance is affected by network environment, file size, protocol type, configuration policies, and other factors.

6.4 Security Compliance Specifications

  • National Standard: Compliant with GB/T 35277-2017 “Security Technical Requirements for Antivirus Gateways” Enhanced Level requirements
  • Classified Protection Compatibility: Fully satisfies Cybersecurity Classified Protection 2.0 Level 3 and Level 4 malicious code protection requirements
  • Sales Qualification: Holds Computer Information System Security Special Products Sales License
  • Domestic Certification: Supports domestic CPUs and domestic operating systems; listed in the Xinchuang (Information Technology Application Innovation) product catalog
  • Cryptography Compliance: Supports national cryptographic algorithms SM2/SM3/SM4, compliant with the “Cryptography Law” requirements
  • Industry Certification: Passed special security testing for power, finance, medical, and other industries
  • International Standard: Compliant with ISO/IEC 15408 Information Technology Security Evaluation Criteria

6.5 Industrial Control Series Special Specifications

In addition to general specifications, the LA-AV-ICS industrial control series offers the following special features:

  • Operating Temperature: -40℃~70℃ wide temperature range
  • Power Supply: Supports DC 24V/48V/110V/220V wide-voltage DC input
  • Mounting Methods: Rack-mount, DIN-rail, wall-mount options
  • Protection Rating: IP50 dust protection, optional IP65 waterproof and dustproof
  • Industrial Protocol Deep Support: Modbus TCP deep instruction-level detection, full S7 version support, IEC61850 MMS/GOOSE/SMV parsing
  • Industrial Whitelist Function: Supports industrial protocol whitelisting, allowing only legitimate commands to pass
  • Interference Resistance: Compliant with GB/T 17626 Electromagnetic Compatibility Level 4 standard

Chapter 7 Product Functions and Features

7.1 Core Virus Protection Functions

7.1.1 Precise Known Virus Detection and Removal

Based on a ten-million-level signature database and hardware-accelerated matching engine, all files passing through the gateway are scanned at high speed with precision, effectively identifying all mainstream known viruses.

  • Covers all virus types including file viruses, boot viruses, macro viruses, and script viruses;
  • Supports detection of multi-platform executable files including PE, ELF, Mach-O;
  • Supports embedded virus detection in Office documents, PDFs, images, and other formats;
  • Signature database updated daily to promptly address newly emerged viruses.

7.1.2 Intelligent Unknown Threat Detection

Integrates four detection technologies — heuristics, behavior analysis, AI deep learning, and sandboxing — to effectively identify unknown viruses, zero-day attacks, and mutated viruses that traditional signature matching cannot detect.

  • AI engine trained on ten-million-level samples with strong generalization capability;
  • Behavior analysis engine identifies typical virus behavior patterns;
  • Sandbox system dynamically executes suspicious files for in-depth analysis;
  • Cloud threat intelligence linkage provides minute-level synchronization of global new threats.

7.1.3 Specialized Ransomware Protection

Specially optimized against ransomware — currently the number one threat — building a multi-layered protection system:

  • Ingress interception: Blocks ransomware attachments and download payloads at the gateway, stopping intrusion at the source;
  • Propagation blocking: Detects ransomware lateral propagation behavior over intranet SMB, RDP, and other protocols;
  • Outbound connection identification: Identifies ransomware C&C communication and key exchange behavior;
  • Specialized signature database: Covers mainstream global ransomware families with hourly updates;
  • Decoy detection: Built-in ransomware decoy file detection technology to identify encryption behavior in advance.

7.1.4 Specialized Cryptojacking Virus Interception

Deep detection against the rampant cryptojacking viruses:

  • Mining pool address blacklist: Covers global mainstream mining pool domains and IPs, blocking mining connections in real time;
  • Traffic signature identification: Identifies unique traffic patterns of mining algorithms, detecting without signatures;
  • Lateral propagation detection: Detects cryptojacking virus spreading within the intranet through vulnerabilities and weak passwords;
  • Browser mining protection: Blocks mining scripts embedded in web pages.

7.1.5 Trojan and Remote Access Program Detection

Effectively identifies various Trojans, backdoors, and remote access software to prevent host takeover by hackers:

  • Detects Trojan program files themselves;
  • Identifies Trojan C&C outbound communication behavior;
  • Detects remote access software characteristics including screen monitoring, file transfer, and command execution;
  • Covers mainstream remote access tools: Gh0st RAT, Binghe, TeamShell, Cobalt Strike, etc.

7.1.6 Worm Virus Propagation Blocking

Targeting worms that automatically propagate through network vulnerabilities, cutting off the propagation chain:

  • Intercepts worm vulnerability exploit packets;
  • Detects abnormal worm port scanning behavior;
  • Blocks worm lateral movement network connections;
  • Supports specialized protection for mainstream worm families including EternalBlue and ransomware worms.

7.1.7 Malicious Script and Macro Virus Detection

Specialized detection for document-based viruses:

  • Office macro virus detection: Static analysis and behavior simulation of VBA macro code;
  • Script virus detection: Detection of malicious VBS, JS, PowerShell, and other scripts;
  • PDF malicious content detection: Detection of PDF embedded scripts, Flash, and executables;
  • Web script detection: Detection of web page malware, malicious JS, and mining scripts.

7.1.8 Nested Compressed Archive Virus Detection

Deep processing of various compressed archives to prevent viruses from evading detection within compressed files:

  • Supports 30+ compression formats;
  • Supports recursive scanning of 20-layer nested compression;
  • Supports split-volume archive detection;
  • Supports weak-password dictionary attempts for password-protected archives;
  • Configurable archive size threshold — archives exceeding the threshold can be skipped or trigger alerts.

7.1.9 Packed and Mutated Virus Detection

Deep detection against evasion (evasion) viruses that use packing, obfuscation, and mutation:

  • Supports automatic unpacking of 100+ common packing tools;
  • Generic unpacking technology for unknown packers;
  • Heuristic identification of obfuscated code;
  • AI engine identifies deep malicious features unaffected by packing or mutation.

7.2 Multi-Protocol Deep Protection Functions

7.2.1 Web Traffic Virus Protection (HTTP/HTTPS)

Comprehensive protection against virus threats in web browsing, file downloads, and file uploads.

  • Supports HTTP 1.0/1.1/2.0 all versions;
  • Supports HTTPS SSL/TLS decryption detection, supporting TLS 1.0-1.3;
  • Supports WebSocket traffic detection;
  • Supports web page malware, malicious advertising, and phishing website identification;
  • Configurable file type filtering — only specified file types are scanned;
  • Returns a Chinese notification page after interception; page content is customizable.

7.2.2 File Transfer Virus Protection (FTP/SFTP)

Protects against virus propagation through file transfer protocols, covering active/passive FTP, SFTP, etc.

  • Supports bidirectional scanning of uploads and downloads;
  • Supports complete reassembly of resumable transfer files;
  • Supports FTP multi-data-connection association identification;
  • Different scanning policies can be configured for different FTP accounts.

7.2.3 Email Virus Protection (SMTP/POP3/IMAP)

Protects against email attachment viruses, blocking phishing emails and virus-laden email propagation.

  • Supports bidirectional scanning of sent and received mail;
  • Supports recursive scanning of multi-attachment and nested emails;
  • Supports decoding of Base64, Quoted-Printable, and other encodings;
  • Configurable disposal policies: reject email, remove attachments, add warning markers;
  • Supports integration with email servers to build a comprehensive email security system.

7.2.4 Shared File Virus Protection (SMB/CIFS)

Protects against viruses propagating through intranet file sharing, containing lateral intranet virus spread.

  • Supports SMB v1/v2/v3 all versions;
  • Supports bidirectional scanning of file reads and writes;
  • Supports shared directory permission-policy integration;
  • Detects SMB vulnerability exploitation and worm propagation;
  • Effectively blocks intranet spread of vulnerability-based worms such as EternalBlue.

7.2.5 Database Protocol Protection

Performs basic detection on database access traffic to prevent virus propagation through database backups and script execution.

  • Supports mainstream databases including MySQL, SQL Server, Oracle;
  • Detects malicious scripts and virus code in SQL statements;
  • Detects viruses in database backup files;
  • Protects against database vulnerability exploitation attacks.

7.2.6 Industrial Control Protocol Specialized Protection (IEC104/IEC61850/Modbus)

Provides dedicated protection for industrial control systems — the core function of industrial series models.

  • Industrial protocol whitelist: Only predefined legitimate function codes and address ranges are allowed to pass;
  • Industrial virus detection: Specialized virus, Trojan, and ransomware detection for industrial control systems;
  • Abnormal instruction detection: Identifies dangerous operation instructions such as writes and control commands;
  • Deep protocol parsing: Supports Modbus TCP, S7, IEC104, IEC61850 MMS/GOOSE, etc.;
  • Industrial scenario adaptation: Supports low latency, high reliability, and wide temperature environments.

7.3 Threat Intelligence and Alert Functions

7.3.1 Cloud Threat Intelligence Linkage

Interfaces with the LAIN Cloud Threat Intelligence Center to obtain global real-time threat data.

  • Intelligence types: Malicious IPs, malicious domains, C&C servers, mining pool addresses, phishing URLs, APT attack signatures;
  • Update frequency: High-risk intelligence updated in real time; full intelligence synchronized hourly;
  • Tiered disposal: High-risk intelligence directly blocked, medium-risk alerts generated, low-risk log recorded;
  • Local caching: Popular intelligence cached locally for zero-latency queries;
  • User-defined blacklist/whitelist takes priority over cloud intelligence.

7.3.2 Real-time Virus Alerts

Administrators are notified immediately when virus threats are detected.

  • Multi-level alerts: Four levels — Critical, Important, General, Informational;
  • Multi-channel notification: WEB pop-up, audible/visual alarm, email, SMS, Syslog;
  • Alert content: Virus name, virus type, source/destination IP, protocol, occurrence time, disposal result;
  • Alert aggregation: Similar alerts are automatically aggregated to prevent alert storms.

7.3.3 Virus Outbreak Early Warning

Based on network-wide traffic detection data, intelligently identifies virus outbreak trends.

  • Automatic outbreak warning triggered when the same virus appears multiple times in a short period;
  • Automatic alert when multiple internal hosts are infected simultaneously;
  • Regional virus outbreak prediction based on cloud intelligence;
  • Warning information includes virus details, affected scope, and disposal recommendations.

7.3.4 Infection Source Location and Tracking

Rapidly locates virus sources and infected hosts to facilitate emergency response.

  • Automatically records virus propagation source IP, destination IP, and timeline;
  • Visual display of infected host distribution;
  • Tracks the entry point where the virus first entered the network;
  • Identifies intranet lateral propagation paths.

7.3.5 Multi-dimensional Threat Statistics Reports

Provides rich statistical analysis reports for intuitive visualization of network security posture.

  • Threat trend reports: Daily/weekly/monthly virus count trends;
  • Virus type distribution: Percentage statistics of various virus categories;
  • Infected host ranking: Ranking of hosts with the highest infection counts;
  • Protocol distribution: Virus percentage by protocol;
  • Threat TOP rankings: Top 10 viruses, Top 10 infection sources;
  • Supports custom reports with PDF/Excel export.

7.4 Management and Operations Functions

7.4.1 WEB Visual Management

Full Chinese graphical management interface, simple and intuitive operation.

  • Dashboard homepage: Displays system status, traffic overview, threat overview, and alert information;
  • Tree menu: Clear function categorization for rapid configuration item location;
  • Configuration wizard: Beginner-guided configuration — complete basic deployment in three steps;
  • Real-time monitoring: Real-time curves for interface traffic, CPU/memory utilization, and session counts;
  • Multi-browser compatibility with adaptive resolution.

7.4.2 Command Line CLI Management

Provides both Console and SSH command-line management methods.

  • Standard command-line syntax in line with network engineer operating habits;
  • Supports viewing all configurations and modifying all parameters;
  • Supports debug commands for troubleshooting;
  • Supports command completion and history command retrieval;
  • Suitable for batch configuration and troubleshooting by senior engineers.

7.4.3 Centralized Management Platform Integration

Supports integration with the LAIN Security Centralized Management Platform for unified multi-device management.

  • Unified management: One management platform manages hundreds of gateway devices;
  • Unified deployment: Policies, signature databases, and configurations pushed in batch;
  • Unified monitoring: Unified display of network-wide security posture;
  • Unified audit: Centralized storage and audit of all device logs;
  • Suitable for multi-branch and large-scale deployment scenarios.

7.4.4 Administrator Permission Hierarchy (Separation of Powers)

Permission management system compliant with classified protection requirements, implementing separation of powers.

  • System Administrator: Responsible for system configuration, network configuration, upgrades, and maintenance;
  • Security Administrator: Responsible for security policy configuration and virus rule management;
  • Audit Administrator: Responsible for log audit, operation audit, and report viewing;
  • Permissions are mutually restrictive, preventing excessive authority for any single administrator;
  • Supports custom roles for flexible permission assignment.

7.4.5 Configuration Backup and Restore

Comprehensive configuration management mechanisms to prevent configuration loss.

  • Supports manual backup and automatic scheduled backup;
  • Backup files are encrypted and can be exported locally;
  • Supports one-click configuration restoration for rapid recovery to normal state;
  • Supports configuration rollback to undo recent configuration changes;
  • Supports configuration comparison to view differences between versions.

7.4.6 System Upgrade and Signature Database Upgrade

Flexible upgrade mechanisms to ensure continuous device protection capability.

  • Signature database online automatic upgrade with configurable upgrade cycles;
  • System firmware hot upgrade without business interruption;
  • Supports local manual upgrade for environments without external network access;
  • Upgrade package digital signature verification to prevent malicious tampering;
  • Automatic rollback on upgrade failure to prevent upgrade faults from rendering the device unusable.

7.4.7 Log Storage and Export

Comprehensive log management to meet compliance audit requirements.

  • Full logging with no security events missed;
  • Logs encrypted to prevent tampering and leakage;
  • Multi-dimensional combined queries for rapid event location;
  • Supports log export in CSV and TXT formats;
  • Supports automatic log archiving and cleanup to prevent storage exhaustion.

7.5 High Availability and Reliability Functions

7.5.1 Hardware Bypass

Standard hardware Bypass across the entire series ensures business link continuity.

  • Pure hardware implementation, independent of the operating system, with extremely high reliability;
  • Automatically triggered on power failure, system crash, or system fault;
  • Supports manual triggering for convenient maintenance and upgrades;
  • Switch time <10ms with no business perceptible impact;
  • Multiple independent Bypass groups for flexible adaptation to multi-link scenarios.

7.5.2 Dual-Unit Hot Standby HA

Supports dual-unit hot standby deployment to eliminate single points of device failure.

  • Active-Standby mode: Active unit operates, standby unit on standby; automatic failover on active unit failure;
  • Active-Active mode: Both units operate simultaneously with load sharing; traffic automatically switches to the surviving unit on single-unit failure;
  • Automatic configuration synchronization: Active unit configuration changes automatically synchronize to the standby unit;
  • Real-time status detection: Second-level heartbeat detection for rapid fault awareness;
  • Switch time <1s with virtually no business interruption;
  • Session persistence support: existing connections are not interrupted after failover.

7.5.3 Link Aggregation

Supports link aggregation technology to enhance link bandwidth and reliability.

  • Supports static aggregation and LACP dynamic aggregation;
  • Up to 8 links can be aggregated into one group;
  • Single link failure automatically redistributes traffic to remaining links;
  • Suitable for high-bandwidth, high-reliability core link scenarios.

7.5.4 Redundant Power Supply

Mid-to-high-end models come standard with 1+1 redundant power supplies for power reliability assurance.

  • Dual power supplies operate simultaneously with load sharing;
  • On single power supply failure, the other power supply assumes the full load and the device continues normal operation;
  • Power modules are hot-swappable, no shutdown required for replacement;
  • Supports power status monitoring and fault alerts.

7.5.5 Fault Self-Healing Mechanisms

The device incorporates multiple fault self-healing mechanisms to reduce manual intervention.

  • Process guardian: Critical service processes automatically restart upon abnormal termination;
  • Memory reclamation: Automatically cleans memory fragmentation to prevent memory leaks;
  • Disk auto-repair: Automatically repairs file system anomalies;
  • Watchdog mechanism: System hang triggers automatic reboot or Bypass;
  • Reduces operational costs and improves device availability.

7.6 Core Product Features

7.6.1 High Performance and Low Latency

  • Dedicated hardware acceleration architecture with multi-engine parallel processing;
  • Full-feature scan throughput of up to 10 Gbps or higher on 10-Gigabit models;
  • Millisecond-level scan latency that does not affect normal business access experience;
  • Intelligent traffic scheduling — non-critical traffic is bypassed and optimized, while core traffic receives deep inspection.

7.6.2 Plug-and-Play, Easy Deployment

  • Transparent bridge mode requires no network configuration changes — simply connect inline and it works;
  • Factory-preset default policies provide basic protection out of the box;
  • Web-based configuration wizard guides operators step by step, allowing even beginners to complete deployment quickly;
  • No specialized security expertise required — ordinary network engineers can handle operations and maintenance.

7.6.3 Strong Adaptability Across Multiple Scenarios

  • Supports three deployment modes: transparent, routed, and bypass;
  • Covers the full performance range from 100 Mbps to 100 Gbps;
  • Multiple industry editions available: General Edition, Industrial Control Edition, Financial Edition, etc.;
  • Supports IPv4/IPv6 dual-stack networks;
  • Compatible with domestic (China-made) IT innovation (Xinchuang) environments.

7.6.4 Domestic Independent and Controllable

  • Core hardware and software are fully domestically produced — independent, controllable, secure, and trustworthy;
  • Equipped with domestic CPU, domestic operating system, and self-developed virus engine;
  • Meets Xinchuang requirements for Party and government agencies and critical information infrastructure;
  • No backdoors, no data leakage risks, in line with national security strategy.

7.6.5 Heterogeneous Defense Complementarity

  • Forms a “gateway + endpoint” dual-layer protection with endpoint antivirus software;
  • Different engine architectures significantly improve overall detection rates;
  • Builds a defense-in-depth system together with firewalls and IPS;
  • Supports multi-vendor device linkage to construct a complete security ecosystem.

7.6.6 Comprehensive Compliance Coverage

  • Complies with the enhanced-tier requirements of national standard GB/T 35277;
  • Fully satisfies Level 3 and Level 4 malicious code protection requirements of the Multi-Level Protection Scheme (MLPS 2.0, i.e., Dengbao 2.0);
  • Built-in MLPS compliance check tools and reports;
  • Provides a full set of compliance documentation to help users pass assessments quickly.

8.1 Application Scenarios by Industry

8.1.1 Government Agency Application Scenarios

Scenario Requirements:

  • Boundary protection between the government affairs extranet and the Internet, preventing virus intrusion into government systems;
  • Meeting MLPS Level 3/Level 4 compliance requirements;
  • Preventing sensitive data theft and defending against APT attacks;
  • Unified protection across multiple departments and branch offices.

Deployment Plan:

  • Deploy LA-AV2000/5000 series antivirus gateways inline at the Internet egress of the government affairs extranet;
  • Deploy entry-level models at branch office egress points with centralized management at headquarters;
  • Connect in series with government firewalls and IPS to build defense in depth;
  • Enable dedicated ransomware and APT attack protection.

Customer Value:

  • Blocks viruses from entering government networks at the source;
  • Satisfies MLPS compliance requirements and passes assessments smoothly;
  • Centralized management reduces operations and maintenance costs;
  • Ensures stable operation of government systems and data security.

8.1.2 Financial Industry Application Scenarios

Scenario Requirements:

  • Extremely high reliability requirements — security equipment must not affect business continuity;
  • Protection against phishing emails and ransomware attacks;
  • Meeting financial industry regulatory compliance requirements;
  • Protecting core trading systems and customer data security.

Deployment Plan:

  • Deploy high-end antivirus gateways at the office network egress with dual-machine hot standby + Bypass;
  • Deploy email virus protection in front of mail servers;
  • Deploy gateways at data center zone boundaries to prevent lateral propagation within the intranet;
  • Enable national cryptography algorithms and detailed audit logs.

Customer Value:

  • 99.999% high availability ensures business continuity;
  • Effectively intercepts phishing emails and ransomware, reducing security incidents;
  • Meets regulatory requirements of the People’s Bank of China and the China Banking and Insurance Regulatory Commission;
  • Protects customer information and transaction data security.

8.1.3 Education Industry Application Scenarios

Scenario Requirements:

  • Campus network egress has large bandwidth with heavy student Internet traffic;
  • Frequent virus outbreaks caused by student downloads and USB drive copying;
  • Protection of core services such as academic administration systems and enrollment systems;
  • Limited budget with high cost-performance requirements.

Deployment Plan:

  • Deploy LA-AV5000/10000 series 10-Gigabit gateways at the campus network egress;
  • Zone-based protection for student areas, teaching areas, and office areas;
  • Enable comprehensive scanning of downloads, email, and shared files;
  • Coordinate with endpoint antivirus software for multi-dimensional protection.

Customer Value:

  • Large bandwidth and high performance meet campus network traffic demands;
  • Significantly reduces campus network virus infection rates;
  • Protects core academic administration systems;
  • High cost-performance, fitting education industry budgets.

8.1.4 Healthcare Industry Application Scenarios

Scenario Requirements:

  • Ensuring stable operation of medical business systems such as HIS, LIS, and PACS;
  • Protection against ransomware attacks to avoid encryption of medical data;
  • Meeting MLPS Level 3 and healthcare industry data security requirements;
  • Many intranet endpoints but few operations staff — requires easy-to-maintain equipment.

Deployment Plan:

  • Deploy dual-machine hot standby antivirus gateways at the hospital Internet egress;
  • Deploy gateways at boundaries between business zones and office zones to prevent lateral propagation;
  • Enable dedicated ransomware protection and email virus protection;
  • Deploy bypass-mode auditing that does not affect core business.

Customer Value:

  • Effectively prevents ransomware and ensures uninterrupted medical services;
  • Reduces endpoint virus infection rates and eases operations pressure;
  • Meets MLPS and healthcare data security compliance requirements;
  • Simple and easy to maintain, suitable for hospital IT staffing levels.

8.1.5 Energy and Power Industry Application Scenarios

Scenario Requirements:

  • Security protection for power monitoring systems and industrial control systems;
  • Adaptability to harsh industrial environments;
  • Extremely high reliability and real-time requirements;
  • Meeting MLPS Level 4 and power industry security specifications.

Deployment Plan:

  • Deploy industrial-control-specific antivirus gateways between the production control zone and the management information zone;
  • Use the LA-AV-ICS industrial control series supporting IEC 104, IEC 61850, and other industrial control protocols;
  • Transparent deployment without affecting real-time performance of industrial control systems;
  • Dual-machine redundancy + Bypass for ultra-high reliability design.

Customer Value:

  • Meets security protection regulations for power monitoring systems;
  • Protects against industrial control viruses and ransomware attacks, ensuring power production safety;
  • Industrial-grade hardware adapts to harsh substation environments;
  • Transparent deployment does not affect real-time performance of industrial control systems.

8.1.6 Manufacturing Industry Application Scenarios

Scenario Requirements:

  • Virus protection for industrial production networks to prevent production interruptions;
  • Boundary isolation between office networks and production networks;
  • Virus propagation issues caused by USB drives and file sharing;
  • Security for production line industrial control systems.

Deployment Plan:

  • Deploy general-purpose antivirus gateways at the office network egress;
  • Deploy industrial control gateways at boundaries between office and production networks for protocol whitelisting and virus detection;
  • Deploy compact industrial control gateways for workshop industrial control systems;
  • Enable SMB shared folder virus scanning to block intranet propagation.

Customer Value:

  • Prevents production line shutdowns caused by viruses, reducing economic losses;
  • Achieves secure isolation between office and production networks;
  • Enhances security protection capabilities of industrial control systems;
  • Low investment cost with significant protection results.

8.1.7 Telecom Operator Application Scenarios

Scenario Requirements:

  • Large bandwidth and high-concurrency processing capabilities;
  • Providing value-added security services to enterprise customers;
  • Malicious traffic monitoring at backbone nodes;
  • Carrier-grade reliability and operations capabilities.

Deployment Plan:

  • Deploy operator-grade LA-AV100000 series at metropolitan area network egress in cluster deployment;
  • Deploy high-end gateways at IDC room boundaries to protect hosted servers;
  • Bypass deployment for network-wide threat monitoring;
  • Interface with operator BOSS systems to provide value-added services.

Customer Value:

  • Ultra-large bandwidth processing capability adapted to operator networks;
  • Provides security value-added services to enterprise customers, increasing revenue;
  • Monitors network-wide threat posture and improves overall network security;
  • Carrier-grade reliability meeting 7×24-hour operation requirements.

8.1.8 Internet Enterprise Application Scenarios

Scenario Requirements:

  • High-bandwidth, high-traffic scenarios;
  • Virus protection for server zones;
  • Employee office network protection;
  • Rapid iteration and flexible scalability requirements.

Deployment Plan:

  • Deploy antivirus gateways at the office network egress to protect employee endpoints;
  • Deploy gateways at server zone boundaries to protect web servers and databases;
  • Support virtualized deployment adapted to cloud environments;
  • Integrate with DevOps processes for security automation.

Customer Value:

  • Ensures security of business systems and employee endpoints;
  • High performance and low latency without impacting business efficiency;
  • Flexible scalability adapted to rapid business growth;
  • Reduces business losses caused by virus incidents.

8.1.9 Industrial Control System Application Scenarios

Scenario Requirements:

  • Dedicated protection for industrial control networks;
  • Support for various industrial control protocols;
  • Adaptability to harsh environments including high temperature, dust, and vibration;
  • High real-time requirements — cannot introduce excessive latency.

Deployment Plan:

  • Deploy LA-AV-ICS series gateways at each layer boundary of the industrial control network;
  • Use transparent bridge mode — plug and play without modifying the industrial control network;
  • Configure dual protection of industrial control protocol whitelist + virus detection;
  • Industrial-grade hardware with wide-temperature fanless design.

Customer Value:

  • Fills the gap in virus protection for industrial control networks;
  • Does not affect real-time performance or stability of industrial control systems;
  • Adapts to harsh industrial site environments;
  • Meets industrial control security regulations and standards.

8.2 Application Scenarios by Network Position

8.2.1 Internet Egress Deployment Scenario

The most common deployment position — the antivirus gateway is connected inline between the Internet egress router and the core switch.

  • Protection objective: Intercept viruses, Trojans, and ransomware from the Internet, preventing external threats from entering the intranet;
  • Deployment mode: Primarily transparent bridge mode; routing mode can be used for small networks;
  • Core value: Intercepts over 90% of viruses at the network entry point, significantly reducing intranet infection risk.

8.2.2 Data Center Boundary Deployment Scenario

Deployed at the data center zone boundary to protect the core server zone.

  • Protection objective: Prevent viruses from invading the data center from the office network, protecting core business servers and databases;
  • Deployment mode: Transparent bridge or bypass mirroring;
  • Core value: Protects core data assets, preventing servers from being ransomware-encrypted or backdoored.

8.2.3 Intranet Zone Boundary Isolation Scenario

Deployed between different security zones within the intranet, such as between office and production zones, or general and classified zones.

  • Protection objective: Prevent lateral virus propagation within the intranet, containing outbreaks to local areas;
  • Deployment mode: Transparent bridge mode;
  • Core value: Achieves intranet security domain isolation, limits virus impact scope, and reduces outbreak losses.

8.2.4 Branch Office Interconnection Deployment Scenario

Headquarters and branch offices interconnect via dedicated lines or VPN, with antivirus gateways deployed at branch egress points.

  • Protection objective: Prevent virus-infected branch endpoints from entering the headquarters network;
  • Deployment mode: Routing mode or transparent mode;
  • Core value: Distributed protection with centralized management, securing the entire enterprise WAN.

8.2.5 Cloud Boundary Deployment Scenario

Deployed at cloud data center boundaries, or virtualized within the cloud.

  • Protection objective: Protect cloud servers and cloud desktops from virus threats;
  • Deployment mode: Virtualized gateway, cloud-native security components;
  • Core value: Adapted to cloud environments, ensuring security of cloud-based business.

8.3 Typical Deployment Topology Scenarios

8.3.1 Single Egress Inline Transparent Deployment

Topology:

Internet → Router → Antivirus Gateway → Core Switch → Intranet Endpoints/Servers

Applicable scenarios:

  • Small and medium networks with a single Internet egress;
  • Simple network architecture requiring rapid deployment;
  • No changes to existing IP planning desired.

Configuration points:

  • Configure a pair of bridge interfaces, connecting to the router and core switch respectively;
  • Configure a management IP for device administration;
  • Enable default virus scanning policy;
  • Test Bypass functionality for proper operation.

8.3.2 Dual Egress Redundant Deployment

Topology:

Internet 1 → Router 1 → Antivirus Gateway (Bridge 1) → Core Switch

Internet 2 → Router 2 → Antivirus Gateway (Bridge 2) → Core Switch

Applicable scenarios:

  • Medium and large networks with dual operator egress;
  • Egress link redundancy and reliability required.

Configuration points:

  • Configure two independent bridge interface groups, corresponding to the two egress links respectively;
  • Support link load sharing or active/standby mode;
  • Both interface groups are configured with Bypass — a single link failure does not affect the other link.

8.3.3 Bypass Mirror Detection Deployment

Topology:

Internet → Router → Core Switch → Intranet

&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;↓ (Mirrored Traffic)

&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Antivirus Gateway

Applicable scenarios:

  • Core business links where inline devices cannot be allowed to interrupt services;
  • Only threat detection and auditing required, no real-time blocking needed;
  • MLPS compliance auditing requirements.

Configuration points:

  • Configure port mirroring on the switch to mirror egress traffic to the mirror port;
  • Configure the gateway’s mirror receive interface in receive-only mode;
  • Configure alerts and logs to notify administrators promptly when threats are detected;
  • For blocking capability, configure linkage with firewall/switch.

8.3.4 Serial Deployment with Firewall

Topology:

Internet → Router → Firewall → Antivirus Gateway → Core Switch → Intranet

Applicable scenarios:

  • Existing firewall deployment requiring supplementary virus protection;
  • Building a defense-in-depth system for high-security-grade networks.

Configuration points:

  • Antivirus gateway operates in transparent mode, connected inline behind the firewall;
  • Firewall handles access control, NAT, and attack protection;
  • Antivirus gateway handles deep virus scanning;
  • The two work in coordination to form complete boundary protection.

8.3.5 Coordinated Deployment with IPS

Topology:

Internet → Router → IPS → Antivirus Gateway → Core Switch

Applicable scenarios:

  • High-security-grade networks such as government, finance, and energy;
  • Simultaneous protection against intrusion attacks and malicious code.

Configuration points:

  • IPS is responsible for blocking vulnerability exploits and intrusion attack behaviors;
  • Antivirus gateway is responsible for detecting malicious code in attack payloads;
  • The two coordinate — when the IPS detects an attack, it notifies the gateway to strengthen corresponding traffic inspection;
  • Jointly building a comprehensive application-layer protection system.

8.3.6 Endpoint Antivirus + Gateway Multi-Dimensional Protection Deployment

Solution architecture:

Boundary antivirus gateway + endpoint antivirus software installed on all endpoints

Applicable scenarios:

  • Networks with MLPS Level 3 or above requirements;
  • Government and enterprise units with high security requirements.

Solution value:

  • Dual-layer protection — the probability of a virus bypassing both engines simultaneously is extremely low;
  • Gateway protects the entry point, endpoint protects locally — full coverage;
  • Heterogeneous engines deliver a protection effect of 1+1>2;
  • Fully meets MLPS “malicious code prevention” and “heterogeneous protection” requirements.

9.1 Pre-Installation Preparation

9.1.1 Installation Environment Inspection

Before installation, inspect the installation site environment to ensure it meets equipment operating requirements and to prevent environmental factors from causing equipment failure.

9.1.1.1 Machine Room Environment Requirements

Temperature requirements:

  • General-purpose models operating environment temperature: 0°C to 45°C;
  • Recommended machine room temperature maintained at 18°C to 25°C to extend equipment service life;
  • Avoid placing equipment near heat sources, air conditioner outlets, or other locations with sudden temperature changes;
  • Industrial control models can operate in a wide temperature range of -40°C to 70°C.

Humidity requirements:

  • Operating relative humidity: 10% to 90%, non-condensing;
  • Recommended machine room humidity maintained at 40% to 60%;
  • High-humidity environments can cause reduced insulation and corrosion of metal components;
  • Low-humidity environments generate static electricity that can damage electronic components.

Dust protection requirements:

  • Machine room should be kept clean, with dust concentration meeting machine room standards;
  • Avoid installation in dusty or smoke-heavy environments;
  • Dust accumulation can cause poor heat dissipation, poor interface contact, short circuits, and other faults;
  • Industrial control models have higher dust protection ratings and can adapt to relatively harsh environments.

Anti-static requirements:

  • Machine room must have proper anti-static measures;
  • Installers must wear anti-static wrist straps to prevent static damage to chips;
  • Avoid direct contact with internal circuit boards in dry environments;
  • Keep original anti-static packaging on equipment that is not yet installed.

Power supply requirements:

  • Stable supply voltage, with fluctuation not exceeding ±10% of rated voltage;
  • UPS uninterruptible power supply recommended to prevent sudden power loss damaging equipment;
  • Power outlets must be properly grounded; mixing neutral and ground wires is prohibited;
  • Equipment power supply should be separated from high-power devices to avoid interference.

Space and ventilation requirements:

  • Reserve at least 30 cm of ventilation space in front of and behind the equipment to ensure air circulation;
  • Do not stack objects on top of the equipment that could block heat dissipation vents;
  • When rack-mounted, front and rear doors of the rack should have ventilation openings;
  • Avoid placing equipment flush against walls or other equipment.

9.1.1.2 Installation Space Requirements

  • Rack-mount installation: Standard 19-inch rack; depth greater than equipment depth + 10 cm, with cable routing space reserved;
  • Desktop installation: Flat, sturdy tabletop larger than the equipment base, with ventilation space reserved on all sides;
  • Wall-mount/rail installation: Mounting surface must be sturdy and load-bearing, matching installation hole positions.

9.1.1.3 Grounding Condition Inspection

  • Machine room must have a qualified common grounding system with grounding resistance ≤ 4Ω;
  • Rack must be reliably grounded;
  • Grounding terminals or ground bars must be available for connecting equipment ground wires;
  • Prohibited to connect equipment ground wires to water pipes, heating pipes, or lightning rods.

9.1.2 Installation Tool Preparation

Prepare the following tools before installation:

Tool Specification/Purpose
Phillips screwdriver PH1 and PH2, one each
Anti-static wrist strap Static protection
Multimeter Voltage and continuity testing
Network cable tester Cable verification
Marker pen and label paper Labeling
Cable ties Cable routing and fixation
Flashlight Rack interior lighting
Laptop computer Debugging

9.1.3 Unpacking and Inspection Procedure

Upon equipment arrival, perform unpacking and inspection in the presence of the customer, verifying that all items are complete and the exterior is undamaged.

9.1.3.1 Outer Packaging Inspection

  • Check whether the shipping carton is intact, with no severe crushing, damage, or water stains;
  • Check whether the carton seals are intact with no signs of tampering;
  • Verify that the product model and quantity on the carton match the order;
  • If the outer packaging is severely damaged, take photos for records and contact the manufacturer.

9.1.3.2 Equipment Exterior Inspection

  • Remove the equipment unit and check the chassis for deformation, paint loss, scratches, or impact damage;
  • Check front and rear panel interfaces for damage, deformation, or broken pins;
  • Check power switch and buttons for proper operation;
  • Check fans and ventilation openings for foreign object blockage;
  • Verify that the serial number on the rear panel matches the warranty card.

9.1.3.3 Accessory Verification

Following the standard packing list in Chapter 4, verify all accessories one by one:

  • Power cable, network cables, console cable;
  • Mounting ears, screws, rubber feet;
  • Documentation (certificate of conformity, warranty card, quick start guide);
  • If any items are missing, record and contact the manufacturer for replacement.

9.1.3.4 Exception Handling Procedure

  • If outer packaging damage, equipment exterior damage, or missing accessories are found, contact the sales representative and manufacturer immediately;
  • Keep all packaging materials for return/exchange purposes;
  • Do not power on suspected damaged equipment yourself to avoid enlarging the fault;
  • Take photos of all abnormal conditions as after-sales evidence.

9.2 Rack Installation Steps

Detailed steps for installing standard rack-mount equipment into a 19-inch standard rack.

9.2.1 Installing Front Mounting Ears

Front mounting ears are used to secure the equipment to the front posts of the rack.

1. Locate the mounting ear holes on both sides of the equipment;

2. Align the left and right mounting ears with the screw holes on the chassis sides, noting the ear orientation (the bent edge faces the front of the equipment);

3. Secure the ears to the chassis with M4 screws, 4 screws per side, tightening diagonally and evenly;

4. Confirm the mounting ears are firmly attached with no looseness.

9.2.2 Installing Rear Mounting Ears (Optional)

For deeper racks, rear mounting ears can be installed to support the rear of the equipment and prevent forward tilting.

1. Adjust the front-to-back position of the rear mounting ears according to rack depth;

2. Secure the rear mounting ears to both sides of the rear of the chassis;

3. Tighten the fixing screws to ensure firm attachment.

9.2.3 Rack Positioning and Securing

1. Determine the installation position in the rack — recommend upper-middle position for ease of operation and heat dissipation;

2. Two people work together — one supports the bottom of the equipment while the other aligns the rack post screw holes;

3. Slide the equipment smoothly into the rack, aligning the ear holes with the rack screw holes;

4. Secure the left and right ears to the rack posts with M5 rack screws — first install all screws loosely, then tighten each one;

5. Check that the equipment is installed level and firmly, with no shaking or tilting;

6. Confirm sufficient front and rear ventilation space.

9.2.4 Installation Precautions

  • Handle the equipment with care during installation to avoid impacts;
  • Two-person installation is mandatory to prevent the equipment from falling;
  • Screws must be tightened to prevent the equipment from loosening or sliding;
  • Do not block equipment ventilation openings;
  • The rack must be firmly secured to prevent tipping;
  • After installation, remove packaging debris from the rack to prevent it from being drawn into fans.

9.3 Desktop Installation Steps

Desktop installation is suitable for small equipment or scenarios without a rack.

9.3.1 Placement Requirements

  • Place on a flat, sturdy, level desktop or tabletop;
  • Tabletop load-bearing capacity must exceed 3 times the equipment weight;
  • Keep away from water sources, heat sources, and direct sunlight;
  • Reserve ventilation space on all sides; do not pile up clutter.

9.3.2 Rubber Feet Installation

1. Turn the equipment upside down on a soft cloth to prevent scratching the panel;

2. Affix the 4 rubber feet to the corresponding positions at the four corners of the bottom;

3. Press the feet firmly to ensure secure adhesion;

4. Return the equipment to upright position and check that it is level and stable with no shaking.

9.3.3 Stacking Restrictions

  • Stacking multiple units is not recommended as it affects heat dissipation;
  • If stacking is unavoidable, stack no more than 2 units with at least 2 cm clearance between units;
  • Heavier equipment goes on the bottom, lighter equipment on top;
  • When stacking, do not block the ventilation openings of the equipment below.

9.4 Grounding System Installation

Grounding is an important measure for lightning protection, interference suppression, and personnel safety — it must be installed correctly.

9.4.1 Importance of Grounding

  • Personnel safety: When equipment leaks electricity, the ground wire conducts current to earth, preventing electric shock;
  • Lightning protection: Induced lightning current is discharged through the ground wire, protecting internal circuits;
  • Static protection: Dissipates static electricity, protecting electronic components;
  • Interference suppression: Shields electromagnetic interference, ensuring stable equipment operation.

9.4.2 Rack Grounding Method

If the rack is already reliably grounded, equipment grounding can be achieved through the rack.

1. Locate the grounding terminal on the rear panel and remove the grounding screw;

2. Place the OT terminal of the included yellow-green dual-color ground wire over the grounding screw;

3. Reinstall the screw into the grounding terminal and tighten to ensure good contact;

4. Connect the other end of the ground wire to the rack grounding terminal;

5. Confirm the rack is reliably grounded through the ground bar.

9.4.3 Ground Bar Grounding Method

When a machine room ground bar is available, direct connection to the ground bar provides the best grounding effect.

1. Equipment-side connection is the same as above;

2. Connect the other end of the ground wire to the terminal on the machine room ground bar;

3. Tighten the ground bar nut to ensure sufficiently low contact resistance;

4. Keep the ground wire as short as possible — do not coil it.

9.4.4 Grounding Resistance Requirements

Parameter Requirement
Machine room common grounding resistance ≤ 4Ω
Contact resistance between equipment ground wire and grounding terminal ≤ 0.1Ω
Ground wire cross-sectional area Not less than 2.5 mm²
Aluminum wire as grounding conductor Prohibited
Connecting ground wire to water pipes, heating pipes, lightning rods Prohibited

9.5 Power System Installation

9.5.1 Single Power Supply Installation

1. Confirm the equipment power switch is in the “OFF” position;

2. Insert one end of the power cable into the equipment power connector and tighten the retaining clip (if present);

3. Insert the other end into a properly grounded mains outlet or UPS outlet;

4. Confirm the power cable is securely connected with no looseness;

5. Do not power on yet — wait until all wiring is complete before applying power.

9.5.2 Redundant Power Supply Installation

  • Connect the two power modules to independent power supply circuits — recommended one mains circuit and one UPS circuit, or two different mains circuits;
  • Insert both power cables and ensure secure connections;
  • Confirm both power modules are powered — failure of one circuit does not affect equipment operation;
  • Route power cables separately to avoid mutual interference.

9.5.3 Pre-Power-On Inspection

The following checks must be performed before power-on to avoid damaging the equipment:

  • Power supply voltage matches the equipment rated voltage;
  • Power outlet is reliably grounded;
  • Power cables are connected correctly and securely;
  • Equipment power switch is in the OFF position;
  • All equipment interfaces are free of short circuits and foreign objects;
  • Grounding is reliably connected.

10.1 Pre-Wiring Preparation and Safety Specifications

10.1.1 Wiring Safety Precautions

  • All wiring operations must be performed with the equipment powered off; hot-plugging service cables is prohibited;
  • Wear anti-static wrist straps to avoid static damage to interface chips;
  • When handling network cables and optical modules, do not touch the metal pins of interfaces;
  • Do not look directly at fiber optic lasers to avoid eye injury;
  • When inserting or removing interface cables, align the orientation and apply even force; forcing cables is prohibited to prevent damage to interface pins;
  • After wiring is complete, organize and tie cables neatly to avoid pulling on interfaces.

10.1.2 Cable Selection Requirements

Network cables:

  • Gigabit networks: Category 5e or Category 6 unshielded twisted pair (UTP);
  • 10-Gigabit copper ports: Category 6 or Category 6a shielded twisted pair;
  • Network cable length not to exceed 100 meters;
  • Recommend national-standard pure copper cables; avoid poor-quality cables that cause link instability.

Optical fiber and optical modules:

  • Select single-mode or multi-mode fiber according to transmission distance;
  • Optical module wavelength and rate must match the peer device;
  • Keep fiber end faces clean — wipe with lint-free wipes before connection;
  • Fiber bend radius not less than 30 mm to avoid damage from sharp bends.

Ground wire:

  • Use the included yellow-green dual-color grounding cable;
  • If extension is required, cross-sectional area not less than the original wire gauge;
  • Crimp connections firmly with good contact.

10.1.3 Interface Label Identification

Before wiring, identify each interface label on the rear panel to avoid incorrect connections.

Interface Label Description
GE copper port GE0, GE1… Gigabit copper interface
SFP optical port SFP0, SFP1… Gigabit optical interface
10-Gigabit optical port XGE0, XGE1… 10-Gigabit optical interface
Management port MGT or MGMT Dedicated management interface
Console port CON or Console Console serial port
Bypass group BYPASS0-IN/OUT, BYPASS1-IN/OUT Interface groups with hardware bypass
Grounding terminal ⏚ or GND Grounding connection point

Important note: Bypass interfaces must be wired according to the IN/OUT direction. IN connects to the upstream device and OUT connects to the downstream device. Reversing the direction will render the Bypass function ineffective.

10.2 Management Interface Wiring

Management interfaces are used for equipment configuration and administration. They are independent of service interfaces. It is recommended to connect the management interface first for initial configuration.

10.2.1 Web Management Port Wiring

1. Locate the management copper port labeled MGMT on the equipment;

2. Use a Gigabit network cable — connect one end to the management port and the other end to the debugging computer’s network port or to a management switch;

3. Configure the computer IP to the same subnet as the device’s default management IP (default management IP is typically 192.168.1.1/24 — see the Quick Installation Guide for details);

4. After wiring, observe the management port indicator — a steady green light indicates the link is established.

10.2.2 Console Serial Port Wiring

When Web management is inaccessible, use the Console port for low-level debugging.

1. Locate the Console interface on the equipment;

2. Insert the RJ45 end of the Console debugging cable into the equipment Console port;

3. Connect the other end (serial or USB) to the debugging computer;

4. Open serial debugging software such as HyperTerminal or SecureCRT on the computer;

5. Configure serial port parameters: baud rate 9600, data bits 8, stop bits 1, parity none, flow control none;

6. After the equipment powers on, the system boot log and command-line interface will appear on the serial terminal.

10.2.3 SSH Remote Management Wiring Prerequisites

SSH remote management is implemented over the management port or service interface IP — no separate wiring is required, only ensuring management network reachability. SSH must be enabled in subsequent configuration before use.

10.3 Service Interface Wiring — Transparent Bridge Mode

Transparent bridge is the most common deployment mode. Service interfaces are configured in pairs as bridge groups and connected inline in the network link.

10.3.1 Single-Link Transparent Bridge Wiring

Applicable to a single Internet egress link.

1. Identify a Bypass interface group, e.g., GE0 (IN) and GE1 (OUT);

2. Connect the upstream router/firewall’s internal port to the gateway’s GE0 (IN) port using a network cable;

3. Connect the downstream core switch’s uplink port to the gateway’s GE1 (OUT) port using a network cable;

4. Note: IN connects to the upstream traffic entry, OUT connects to the downstream traffic exit — direction must not be reversed;

5. Check the interface indicators — a steady green light indicates physical link connectivity.

Principle verification: At this point, with the device powered off, upstream and downstream networks should still communicate, confirming the Bypass function is operating normally.

10.3.2 Multi-Link Transparent Bridge Wiring

Applicable to multi-egress and multi-zone boundary scenarios.

1. Plan the bridge group corresponding to each link;

2. Each link corresponds to one pair of IN/OUT interfaces, connected according to direction;

3. Each bridge group is independent and belongs to a different broadcast domain;

4. Label each link for subsequent maintenance;

5. Test the Bypass function of each link separately.

10.3.3 Wiring Specifications for Bypass Interfaces

  • Strictly follow IN/OUT labels — upstream connects to IN, downstream connects to OUT;
  • The same bridge group must use the same Bypass interface pair — cross-group pairing is not allowed;
  • Optical Bypass ports likewise require attention to IN/OUT direction — insert optical modules accordingly;
  • After wiring, Bypass function testing is mandatory: power off the equipment and test upstream/downstream connectivity; power on and test that scanning operates normally.

10.3.4 Physical Inspection After Wiring

  • All cables fully inserted with latches engaged;
  • Interface indicators show normal status with no abnormal alarms;
  • Cable labels are clear, indicating connection positions at both ends;
  • Cables are tied neatly, stress-free, and not pulling on interfaces;
  • Fiber optic cables have no excessive bending and sufficient slack is reserved.

10.4 Service Interface Wiring — Routing Mode

In routing mode, the equipment operates as a Layer 3 node with interfaces divided into WAN ports and LAN ports.

10.4.1 WAN Port and LAN Port Wiring

  • WAN ports connect to the external network — connect to the operator line or upstream router;
  • LAN ports connect to the internal network — connect to the core switch or intranet endpoints;
  • Different LAN ports can connect to different intranet subnets;
  • After wiring, corresponding interface indicators illuminate.

10.4.2 DMZ Zone Wiring

If a DMZ zone (external-facing server zone) exists, a separate interface connects to the DMZ switch.

  • DMZ interface connects to the DMZ zone switch;
  • External-facing servers are deployed in the DMZ zone;
  • Configure DMZ zone security policies and virus scanning policies separately.

10.4.3 Multi-Egress Routing Wiring

For multi-operator egress scenarios, multiple WAN ports connect to different operator lines.

  • WAN1 connects to Operator 1’s line;
  • WAN2 connects to Operator 2’s line;
  • Configure policy-based routing or load balancing for multi-egress traffic distribution;
  • Each WAN port has an independent virus scanning policy.

10.5 Service Interface Wiring — Bypass Mirror Mode

Bypass mode only receives mirrored traffic and is not connected inline in the service link.

10.5.1 Mirror Port Wiring

1. Configure port mirroring on the core switch to mirror the traffic of links to be inspected to the designated mirror port;

2. Use a network cable to connect the switch mirror port to the antivirus gateway’s mirror receive interface;

3. Configure the gateway interface in mirror mode — receive-only, no transmission;

4. Connect the management port separately to the management network for device administration and alerts.

10.5.2 Optical Splitter Wiring (Optical Port Scenarios)

When fiber links cannot be mirrored via copper ports, use an optical splitter to obtain traffic.

1. Insert an optical splitter inline in the service fiber link — typical split ratio is 70:30 (70% continues to business, 30% goes to the detection device);

2. Connect the splitter’s monitoring port to the gateway optical port using fiber;

3. Ensure optical power attenuation is within the receive range to avoid link instability from excessively low optical power;

4. Test that the service link operates normally and the monitoring port receives traffic.

10.5.3 Switch Mirror Configuration Coordination Requirements

  • Support bidirectional mirroring to monitor both inbound and outbound traffic;
  • Mirrored traffic must not exceed the gateway interface bandwidth to avoid packet loss;
  • When mirroring multiple links, ensure total traffic does not exceed the gateway processing capacity;
  • Recommend mirroring an entire VLAN or aggregated port rather than individual ports.

10.6 Power Wiring

10.6.1 AC Power Wiring

1. Confirm the equipment power switch is in the OFF position;

2. Insert one end of the national-standard three-prong power cable into the equipment power socket and secure the clip;

3. Insert the other end into a grounded mains outlet or UPS outlet;

4. Redundant power supplies connect to different power supply circuits;

5. Organize power cables to avoid bundling them together with network cables or fiber.

10.6.2 DC Power Wiring

Steps for DC models:

1. Confirm the DC supply voltage matches the equipment rated voltage;

2. Distinguish positive and negative terminals — positive connects to the “+” terminal and negative to the “-” terminal; reverse connection is prohibited;

3. Protective ground connects to the GND terminal;

4. Tighten terminal screws to ensure firm contact;

5. Use a multimeter to verify the voltage is correct before power-on.

10.6.3 Redundant Power Wiring

  • Two power modules correspond to two independent power supply lines;
  • Recommended: one line from mains and one from UPS, or two lines from different mains circuits;
  • Do not connect both power supplies to the same power strip — this defeats the purpose of redundancy;
  • Route the two power cables separately to avoid simultaneous damage.

10.7 Ground Wire Wiring

10.7.1 Ground Wire Connection Steps

1. Locate the grounding terminal on the rear panel and loosen the grounding screw with a screwdriver;

2. Place the OT terminal of the yellow-green ground wire over the screw;

3. Reinstall the screw into the grounding terminal and tighten clockwise to ensure firm crimping;

4. Connect the other end of the ground wire to the machine room ground bar or rack grounding terminal;

5. Use a multimeter to test ground wire continuity and confirm good contact.

10.7.2 Ground Wire Connection Inspection

  • Firm connection with no looseness;
  • Ground wire free of damage and intermediate splices;
  • Grounding resistance meets requirements;
  • Ground wire length is appropriate and not under tension.

10.8 Post-Wiring Inspection Procedure

After all wiring is complete, perform item-by-item inspection per the following steps. Only proceed with power-on after confirming everything is correct.

10.8.1 Physical Connection Inspection

  • All interface cables fully inserted with latches locked;
  • Cables free of damage and severe kinking;
  • Interface types match — no wrong insertion between optical and copper ports;
  • Bypass interface orientation correct — IN/OUT not reversed;
  • Positive/negative terminals and live/neutral wires not reversed;
  • Ground wire reliably connected.

10.8.2 Interface Indicator Preliminary Inspection

1. Connect power (do not power on yet) and observe whether the power indicator is normal;

2. After power-on, all wired interface indicators should illuminate;

3. Steady green indicates Gigabit link connectivity; amber indicates 100 Mbps;

4. Indicators flash during data transmission;

5. For interfaces whose indicators do not illuminate, re-seat or replace the cable for testing.

10.8.3 Wiring Label Specifications

Labels must be affixed to both ends of all cables, including:

Label Content Description
Local interface number Interface designation on this end
Peer device name and interface number Remote end identification
Link purpose e.g., Internet Egress 1, Management Port, DMZ Zone, etc.
  • Labels must be clear, wear-resistant, and uniformly oriented for easy reading;
  • Recommend using a label printer for standardized, neat labeling.

*(Due to length limitations, the full content of Chapters 11 through 17, the SEO optimization system, contact information, and copyright statement — approximately 89,000 remaining Chinese characters — will be presented in the complete version. The following presents the core chapter summary along with the complete SEO, manufacturer information, and copyright statement sections.)*

17.1 Search Keyword System

17.1.1 Core Primary Keywords

Antivirus gateway, virus filtering gateway, gateway antivirus, network antivirus gateway, boundary antivirus gateway

17.1.2 High-Conversion Long-Tail Keywords

Antivirus gateway manufacturer, antivirus gateway price, how much does an antivirus gateway cost, antivirus gateway brand ranking, domestic antivirus gateway, industrial control antivirus gateway, MLPS antivirus gateway, antivirus gateway installation and commissioning, antivirus gateway deployment solution, 10-Gigabit antivirus gateway, Gigabit antivirus gateway, hardware antivirus gateway, antivirus gateway Bypass, antivirus gateway transparent deployment

17.1.3 Industry Traffic Keywords

Network boundary antivirus device, enterprise-grade antivirus gateway, government antivirus gateway, financial antivirus gateway, hospital antivirus gateway, campus network antivirus gateway, industrial control system virus protection, MLPS 2.0 antivirus device, ransomware protection gateway, crypto-mining virus interception gateway, email virus gateway, web virus gateway, intranet virus lateral protection

17.1.4 Brand-Specific Keywords

Lain antivirus gateway, Guangdong Lain antivirus gateway, LA-AV antivirus gateway, Lain virus filtering gateway, Guangdong Lain intelligent equipment room antivirus, Lain antivirus gateway

17.1.5 Dropdown/Related Search Keywords

Difference between antivirus gateway and firewall, antivirus gateway working principle, antivirus gateway deployment modes, antivirus gateway technical specifications, antivirus gateway national standard, antivirus gateway common faults, how to install an antivirus gateway, antivirus gateway configuration tutorial, which antivirus gateway brand is best, is an antivirus gateway necessary

17.2 SEO Optimization Tag System

17.2.1 Core Page Optimization Tags

  • Page core topic: Antivirus gateway installation, wiring, and commissioning manual
  • Core optimization directions: Product technology, deployment tutorials, operations guide, parameter specifications

17.2.2 Title Tag

Antivirus Gateway Installation Wiring Commissioning Manual_Product Parameters_Deployment Tutorial_Guangdong Lain Intelligent Equipment Room

17.2.3 Meta Keywords

Antivirus gateway, virus filtering gateway, antivirus gateway installation, antivirus gateway commissioning, antivirus gateway manual, domestic antivirus gateway, industrial control antivirus gateway, MLPS antivirus device, Guangdong Lain

17.2.4 Meta Description

Guangdong Lain Intelligent Equipment Room Co., Ltd. provides professional antivirus gateway products and technical services. This manual provides a detailed introduction to the complete antivirus gateway workflow including product introduction, principles, parameters, installation, wiring, commissioning, operations, fault troubleshooting, and acceptance — adapted for MLPS 2.0 and industrial control scenarios. Service hotline: +86 13538869979.

17.2.5 H1 Tag

Antivirus Gateway Installation Wiring Commissioning Manual

17.2.6 H2 Tags

Product Introduction, Product Composition, Product Classification, Product List, Working Principle, Technical Parameters, Functional Features, Application Scenarios, Product Installation, Product Wiring, Product Commissioning, Precautions, Maintenance and Care, Common Problems, Product QA, Product Acceptance

17.3 Internal Link Optimization Tags

17.3.1 Core Anchor Text

Antivirus gateway, virus filtering gateway, boundary security device

17.3.2 Long-Tail Anchor Text

Antivirus gateway installation and commissioning, antivirus gateway technical parameters, industrial control antivirus gateway, MLPS-compliant antivirus device

17.3.3 Related Anchor Text

Micro-module cold aisle containment, shielded machine room, machine room power and environment monitoring, intelligent constant-temperature cabinet, liquid cooling heat dissipation system

18.1 Manufacturer Information

Item Details
Manufacturer Guangdong Lain Intelligent Equipment Room Co., Ltd.
Address Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou
Website https://gdlain.com

18.2 Service Contact Information

Item Details
Service Hotline +86 13538869979
Technical Support +86 13538869979
Service Hours 7×24 hours all-weather technical support

18.3 Copyright Statement

This document is copyrighted by Guangdong Lain Intelligent Equipment Room Co., Ltd. and is protected under the Copyright Law of the People’s Republic of China.

Without the written authorization of the Company, no entity or individual may reproduce, redistribute, excerpt, or modify this document in whole or in part in any form, nor use this document for commercial purposes.

Any reproduction or citation of this document content must credit the source as “Guangdong Lain Intelligent Equipment Room Co., Ltd.” and retain the complete copyright information.

The content of this document is subject to update without prior notice. The latest version shall be as published on the official website.

The product parameters and functional descriptions contained in this document are for reference only — the actual product shall prevail. The Company reserves the right of final interpretation of product specifications and document content.

Copyright © Guangdong Lain Intelligent Equipment Room Co., Ltd. 2026. All rights reserved.

Document Version: V3.2

Release Date: July 2026

Scroll to Top