2. Project Requirement Description

  • Project Objective: Construct a dedicated magnetic shielding chamber for Transmission Electron Microscopes (TEM), meeting the magnetic field environmental requirements for high-resolution electron microscopy. Effectively shield external power-frequency magnetic fields and stray magnetic field interference, ensuring sub-nanometer imaging precision. Compatible with TEM, Scanning Electron Microscopes (SEM), and other precision electron microscope equipment.
  • Quantity Requirement: One (1) complete set of electron microscope magnetic shielding chamber system; shielding level and dimensions support customization.
  • Functional Requirements: Capable of AC/DC magnetic field shielding; center region magnetic field intensity ≤ 60nT; equipped with electromagnetic shielding, vibration isolation, temperature & humidity control, and filtering systems; adequate installation and operational space for electron microscope equipment.
  • Performance Requirements: DC~10Hz magnetic shielding effectiveness ≥ 46dB; center region residual magnetic gradient ≤ 20nT/m; electromagnetic shielding effectiveness ≥ 80dB.

3. System Composition Introduction

The Magnetic Shielded Electron Microscopy Chamber System comprises 8 core subsystems:

1. Multi-layer Magnetic Shielding Shell System (Permalloy + Electromagnetic shielding layer)

2. Shielding Door and Access Channel System

3. Active Degaussing Compensation System (Optional)

4. Power and Signal Filtering System

5. Vibration Isolation Floor System

6. Temperature & Humidity Control and Ventilation System

7. Grounding and Equipotential System

8. Clean Interior Decoration System

4. Core Product Specifications & Parameters

Core Performance Indicators:

  • Magnetic Shielding Effectiveness: DC~10Hz frequency band ≥ 46dB; Center region AC magnetic field ≤ 60nT pk-pk
  • Residual Magnetic Gradient: ≤ 20nT/m within central 2m × 2m × 2m area
  • Electromagnetic Shielding Effectiveness: 10kHz~1GHz ≥ 80dB
  • Operating Temperature: 20℃ ± 2℃
  • Noise Level: ≤ 45dB
  • Internal Clear Dimensions: Length 5m × Width 4m × Height 3m (customizable)
  • Design Service Life: ≥ 15 years

Key Component Parameters:

  • Magnetic Shielding Layer: High-permeability Permalloy alloy sheets, multi-layer shielding structure, optimized magnetic permeability via heat treatment
  • Electromagnetic Shielding Layer: Composite structure of copper plate / cold-rolled steel plate, achieving dual electromagnetic shielding
  • Shielding Door: Dedicated magnetic shielding door, multi-layer magnetically conductive material sealing, continuous magnetic circuit with shell
  • Active Degaussing System: Three-axis Helmholtz coil matrix, real-time monitoring and dynamic cancellation of external magnetic field disturbances
  • Vibration Isolation Floor: Inertia block + damping spring vibration isolation structure, isolating ground vibration transmission

5. Core Functions & Features of Products

Functions:

  • Magnetic Field Shielding Function: Combines passive shielding via high-permeability materials with active degaussing compensation to greatly reduce indoor magnetic field intensity and fluctuation, ensuring microscope imaging resolution.
  • Multi-dimensional Protection Function: Integrates magnetic shielding, electromagnetic shielding, vibration isolation, and temperature & humidity control for comprehensive protection, fully meeting precision microscope environmental requirements.
  • Equipment Compatibility Function: Pre-installed waveguide interfaces for microscope power, signal, cooling, and exhaust, compatible with mainstream microscope brands.
  • Environmental Stability Function: Equipped with constant temperature & humidity and clean ventilation systems to maintain stable indoor environmental parameters, preventing temperature/humidity fluctuations from affecting equipment performance.

Features:

  • High-precision Magnetic Shielding: Multi-layer Permalloy structure with professional magnetic circuit design provides excellent shielding effectiveness and high magnetic field uniformity, meeting sub-nanometer imaging requirements.
  • Active Compensation Upgrade: Optional active degaussing system dynamically cancels transient magnetic field disturbances (e.g., from subways, elevators), adapting to complex surrounding electromagnetic environments.
  • Integrated Solution: Integrates magnetic shielding, electromagnetic shielding, vibration isolation, and temperature control into a single system, avoiding compatibility issues of separately constructed systems.
  • Low Magnetic Material Craftsmanship: All internal components are manufactured from non-magnetic materials to avoid introducing additional residual magnetism interference.

6. Core Advantages of The Solution

  • Customized Design: Shielding layer count and solutions can be customized based on microscope model, precision requirements, and site conditions, precisely matching equipment environmental specifications.
  • Full-process Turnkey Service: Provides full-chain turnkey service from site survey, solution design, manufacturing, installation & commissioning, to magnetic field testing, delivering a ready-for-installation facility.
  • Confidential Service: Strict confidentiality of research project information and technical parameters; suited for precision laboratory construction needs of universities and research institutes.
  • Core Materials in Stock: Standard specification Permalloy sheets, shielding doors, and filters are kept in stock, ensuring project timelines for scientific research facilities.

7. Manufacturer Strength Introduction

  • Manufacturer Profile: KITOZER (Guangzhou Lai’an Intelligent System Development Co., Ltd.), founded in 2002, is a high-tech enterprise certified under ISO 9001, ISO 14001, and ISO 45001.
  • R&D Capability: Possesses precision instrument magnetic shielding technology R&D capabilities, mastering core processes of multi-layer magnetic shielding design and heat treatment.
  • Industry Experience: Service coverage includes universities, research institutes, semiconductor enterprises, and various other clients; extensive experience in building shielding chambers for TEM, SEM, and spherical aberration-corrected microscopes.
  • Testing Services: Provides on-site magnetic field survey and third-party testing services, ensuring shielding specifications meet design requirements.
  • Manufacturing: Project-confirmed manufacturing with complete quality inspection before shipment.

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Permalloy Magnetic Shielding Layer KTZ-DJ-C08 0.8mm Permalloy, heat-treated, double-layer structure 108 ㎡ 621.58 67130.68 KITOZER Wall + ceiling + floor double layer
2 Electromagnetic Shielding Copper Layer KTZ-DJ-T15 1.5mm copper plate, fully welded, electromagnetic shielding 54 ㎡ 473.58 25573.48 KITOZER Outer electromagnetic shielding
3 Structural Support Frame KTZ-DJ-KJ Non-magnetic stainless steel frame, reinforced support 1 Set 6659.76 6659.76 KITOZER Shell support structure
4 Magnetic Shielding Dedicated Door KTZ-PM-DJ09 Door opening 900×2000mm, multi-layer magnetic shielding sealed 1 Unit 10063.64 10063.64 KITOZER Personnel access channel
5 Active Degaussing System KTZ-XC-Z03 Three-axis coil matrix, real-time dynamic compensation, accuracy ±1nT 1 Set 26639.04 26639.04 KITOZER Active magnetic field cancellation
6 Microscope Dedicated Power Filter KTZ-LB-DJS Three-phase 380V/32A, low leakage magnetic flux, multi-stage filtering 1 Unit 1775.94 1775.94 KITOZER Equipment main power filtering
7 Signal Filtering Interface Group KTZ-LB-XDJ Fiber optic waveguide, USB signal filtering, control signal filtering 1 Group 2663.90 2663.90 KITOZER Equipment signal interface
8 Honeycomb Ventilation Waveguide Window KTZ-BD-DJ30 300×300mm, non-magnetic material, cutoff frequency ≥1GHz 4 Pcs 858.37 3433.48 KITOZER Ventilation & air conditioning interface
9 Vibration Isolation Floor System KTZ-GZ-DJ Damping spring vibration isolation, natural frequency ≤5Hz 20 ㎡ 266.39 5327.81 KITOZER Equipment area vibration isolation
10 Constant Temperature & Humidity Air Conditioning System KTZ-TW-DJ 1.5HP precision air conditioner, accuracy ±0.5℃/±3%RH 1 Set 7103.75 7103.75 KITOZER Temperature & humidity control
11 Clean Decoration System KTZ-ZS-DJ Clean color steel plate, PVC flooring, Class 10,000 cleanroom grade 74 ㎡ 85.83 6351.34 KITOZER Interior clean decoration
12 Non-magnetic Lighting System KTZ-ZM-DJ Non-magnetic LED lighting, no electromagnetic interference 4 Sets 325.59 1302.35 KITOZER Interior lighting
13 Grounding & Equipotential System KTZ-JD-DJ Non-magnetic grounding busbar, single-point grounding, resistance ≤1Ω 1 Set 2219.92 2219.92 KITOZER Grounding discharge system
14 Magnetic Field Detection Sensor KTZ-CG-DJ Three-axis magnetic field sensor, real-time monitoring and display 1 Set 4143.85 4143.85 KITOZER Real-time magnetic field monitoring
15 Installation Accessories Package KTZ-FC-DJ Non-magnetic fasteners, sealants, gaskets, etc. 1 Batch 4735.83 4735.83 KITOZER Construction supporting materials
16 On-site Installation & Commissioning Fee KTZ-AZ-DJ Shell installation, degaussing commissioning, system integration 1 Item 17759.36 17759.36 KITOZER Professional team construction
17 Magnetic Field Performance Testing Fee KTZ-JC-DJ Magnetic field distribution and shielding effectiveness testing, test report issued 1 Item 9619.66 9619.66 KITOZER Third-party precision testing

Total Quotation Price: USD 198904.22

Note: Quotation above excludes taxes and freight. Value-added tax invoice: add 10%; ordinary invoice: add 3%. Freight: collect via logistics. Includes installation, commissioning, and testing services.

9. Quotation Terms & Conditions

  • Currency & Pricing: All prices are quoted in USD. Quotation validity period is 30 days from the date of issue.
  • Incoterms: EXW Guangzhou, China (or as negotiated).
  • Payment Terms: 30% deposit with order, 70% balance before shipment (negotiable).
  • Lead Time: 15-30 working days depending on configuration and order quantity.
  • Packing & Shipping: Packing and shipping costs are quoted separately and will be advised upon order confirmation.
  • Taxes: Quoted prices exclude taxes. Value-added tax invoice: add 10%; ordinary invoice: add 3%.
  • Customization: Additional custom configuration requests may affect pricing and delivery lead time.

10. After-sales Service Description

  • Warranty: 12-24 months warranty depending on product category, covering manufacturing defects and material issues.
  • Technical Support: Lifetime technical support via phone, email, and remote communication channels.
  • Spare Parts: Long-term availability of spare parts for all KITOZER products.
  • On-site Services: Remote troubleshooting and on-site service options available upon request.
  • Commissioning Support: Professional installation and commissioning support to ensure system performance meets specification.

11. Contact & Order Information

  • Ordering: Orders can be placed via the official website at gdlain.com or by contacting the KITOZER sales team directly.
  • Response Time: All inquiries receive a response within 24 hours.
  • Headquarters: Guangzhou Lai’an Intelligent System Development Co., Ltd.
  • Address: Chaitian Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou, China
  • Brand: KITOZER

12. SEO Keywords & Tags

Magnetic shielded electron microscopy chamber, KITOZER quotation, TEM magnetic shielding room factory, electron microscope laboratory shielding room price, high-precision magnetic shielding room custom, microscope magnetic shielding engineering, Permalloy shielding room, precision instrument magnetic shielding room, KITOZER microscope shielding room, EMC shielding chamber price list, cleanroom magnetic shield enclosure quotation, wholesale magnetic shielding chamber quotes

Scroll to Top