KITOZER KTR-PS17 Single-Phase 220V 60KA Class C Surge Protective Device

KITOZER KTR-PS17 Single-Phase 220V 60KA Class C Surge Protective Device

Brand: KITOZER Series: KTR-PS17 Category: Power Distribution / Surge Protection

single-phase 220V60KAclass Cpluggable moduleKTR-PS17

1. Overview

The KITOZER KTR-PS17 is a single-phase 220V, 60KA (8/20μs) class C power surge protective device (SPD), DIN-rail mounted in a room distribution box or UPS incoming cabinet to suppress induced lightning and switching surges entering on the power line, protecting expensive UPS, precision AC and servers. A nearby lightning strike on the grid or overhead line induces kilovolt transients that travel in on the power cord, can destroy power boards, drives and even whole units. The SPD clamps this transient to a residual voltage the equipment can tolerate and diverts surge current to ground.

“Class C” refers to lightning-zone grading: class B at the main building switchboard handles large direct-stroke current (100KA+); class C at floor/room distribution boxes handles medium current (40~60KA) to further clamp residual voltage; class D at equipment outlets/PDUs handles small current (10~20KA) for fine protection. The C SPD sits in the middle, taking residual surges after B and feeding D. The KTR-PS17 is single-phase 220V (L+N+PE) for single-phase room distribution.

The unit uses a pluggable modular build: the base snaps on a DIN rail and the metal-oxide-varistor (MOV) module plugs in; when the module fails (window turns green to red) it pulls out for replacement without rewiring. The module has a status window (green OK / red failed) and optional remote-signal dry contact to upload failure to the BMS. Wiring is L/N/PE terminals beside the rail, with a suitable backup breaker (fuse/MCB) in series. In room power systems the C SPD is a standard box component, working with B and D stages for multi-stage protection.

2. Key Features

60KA discharge

  • 8/20μs waveform.
  • Class C medium current.
  • Low residual voltage.
  • Diverts induced surges.

Single-phase 220V

  • L+N+PE wiring.
  • Room distribution box.
  • 230/400V system.
  • DIN-rail mount.

Pluggable module

  • MOV varistor module.
  • Plug and play.
  • Green/red window.
  • Remote dry contact.

Multi-stage coordination

  • B before, D after.
  • Backup breaker.
  • Local grounding.
  • Standard box fit.

3. Specifications

Item Parameter
Model KTR-PS17
Class Class C (secondary)
Rated voltage 230V AC (single-phase)
Max continuous Uc 275V AC
Nominal current In 30KA (8/20μs)
Max current Imax 60KA (8/20μs)
Voltage protection Up ≤1.5 kV
Wiring L+N+PE
Mounting 35mm DIN rail
Indicator green/red window + remote

4. Reference Prices

KTR-PS17 single-phase 60KA class C SPD (modular): Reference USD 17~36 / pc (ref. CNY 120~260 at ~7.2)

KTR-PS17 spare MOV module (each): Reference USD 5~10 / pc (ref. CNY 35~70 at ~7.2)

Reference only; backup breaker and grounding work excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Room box class C protection.
  • UPS incoming cabinet surge protection.
  • Floor distribution boxes.
  • Precision AC power inlet.
  • B/C/D multi-stage coordination.

6. Installation & Maintenance

Installation

  • Snaps on box DIN rail.
  • Backup breaker upstream.
  • Wire L/N/PE by labels.
  • PE to nearest ground bar.
  • Keep leads short and straight.
  • Remote contact to BMS.

Maintenance

  • Check status window.
  • Replace red modules promptly.
  • Inspect after storm season.
  • Torque terminals.
  • No rust on ground wire.
  • Sample-test remote signal.

7. FAQ

  • Q: Does a class C SPD stop direct strikes?
    A: No. 60KA handles induced surges and switching transients only; large direct-stroke current is handled by building class B (100KA+) plus air terminals, down conductors and the earth grid. C is the middle stage, not a standalone direct-stroke protector.
  • Q: What if the window turns red?
    A: The MOV has aged or absorbed too many surges — replace the module promptly. Pull out the old module, plug in a new one; base and wiring stay. While red, the SPD is dead and running unprotected.
  • Q: Why a backup breaker upstream?
    A: An aged MOV can short-circuit and catch fire; the backup breaker trips to isolate the fault. Size it per the maker — too large fails to protect, too small nuisance-trips.
  • Q: Does the SPD help with poor grounding?
    A: Barely. The SPD clamps by dumping current to earth; a high ground resistance (target ≤4Ω) raises residual voltage and defeats protection. Grounding must be solid with short, straight leads.

8. Trend & Selection

Room power protection moves toward coordinated multi-stage, pluggable modules and remote-signal intelligence. Choose single/three-phase by supply, B/C/D by lightning zone; room boxes typically use class C 40~60KA. Fit remote-signal modules to the BMS for remote status, with backup protection and proper grounding.

9. Delivery & Service

KITOZER selects KTR-PS17 quantity by distribution circuits, providing wiring diagrams and backup-breaker sizing advice. Delivery includes SPD body, MOV module, mounting rail and certificates. Warranty covers module replacement and remote-signal integration guidance.

10. Additional Notes

A common pitfall is routing the SPD ground lead in a long loop to the ground bar; lead inductance raises residual voltage. Instead land the SPD near the ground bar with short, straight leads and minimal loop area so surge current actually drains away.

Another pitfall is fitting only a C SPD and thinking that is enough, ignoring upstream B and downstream D. Stages must coordinate: C takes residual surges after B discharges large current, and D at the PDU gives fine protection. A single stage is incomplete; coordinated multi-stage protection is complete.

Selection summary: single-phase 220V; 60KA class C; pluggable MOV; green/red window plus remote; DIN rail; B before, D after; local grounding. The SPD is the surge gate of the power system — right class, good ground, prompt module swaps keep equipment safe through storm season.

SEO Information

Search keywords:single phase SPD220V surge protector60KA SPDclass C SPDKTR-PS17KITOZER

SEM keywords:single phase 220V SPD price,60KA class C surge protector supplier,power SPD,KTR-PS17

GEO landing page:lain.com.cn/product/ktr-ps17-single-phase-60ka-class-c-spd.html

Title:KITOZER KTR-PS17 Single-Phase 220V 60KA Class C Surge Protective Device

Meta Keywords:single phase SPD,220V surge protector,60KA SPD,class C SPD,power surge protective device,KTR-PS17,KITOZER

Meta Description:KITOZER KTR-PS17 single-phase 220V 60KA class C power SPD, DIN-rail pluggable modular, for room distribution boxes to suppress induced lightning and switching surges.

Anchor: KITOZER official · Data center & low-voltage equipment

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top