KITOZER KTR-GEL200 2V200Ah Deep-Cycle Gel Battery

KITOZER KTR-GEL200 2V200Ah Deep-Cycle Gel Battery

Brand: KITOZER Series: KTR-GEL200 Category: Power Distribution / Energy Storage Battery

2V200Ahgeldeep cycleVRLA sealedKTR-GEL200

1. Overview

The KITOZER KTR-GEL200 is a 2V, 200Ah deep-cycle gel battery in a valve-regulated lead-acid (VRLA) sealed case; the electrolyte is gelled so it does not flow or leak, and the battery can be mounted in any orientation. It is the core energy storage component in UPS backup, telecom sites, off-grid solar and DC switchgear systems, discharging instantly when mains fails to bridge the load.

“Gel” means a gelling agent (fumed silica) is added to the dilute sulfuric acid to turn it into a jelly, differing from flooded lead-acid and AGM absorptive-glass-mat cells. Advantages: no stratification, low thermal-runaway risk, strong deep-cycle acceptance and long cycle life (30%~50% more cycles than ordinary lead-acid), suiting frequent deep discharge. “Deep cycle” means the cell can be repeatedly discharged to high depth (50% even 80% DOD) without significant life loss, unlike starter batteries meant for shallow shallow use.

The KTR-GEL200 is a 2V cell; cells are series-connected to form system voltage: 6 for 12V, 24 for 48V, and 192 for a common 384V UPS DC bus. The cell has an ABS case, flame-retardant valve-regulated cap, tinned copper terminals and inter-cell links. Racked or in cabinets, with insulating separators between layers and series links between cells. In room power and storage systems, gel cells are displacing plain AGM for high-reliability backup thanks to long life, maintenance-free operation and deep-cycle tolerance.

2. Key Features

Gelled electrolyte

  • Gelled, non-flowing.
  • No stratification, no leaks.
  • Low thermal-runaway risk.
  • Mount any orientation.

Deep-cycle long life

  • 50%~80% DOD capable.
  • 30%~50% more cycles.
  • Tolerates frequent cycling.
  • 12~15 yr design life.

VRLA sealed

  • VRLA structure.
  • Sealed valve cap.
  • Maintenance-free.
  • Flame-retardant ABS.

Flexible series

  • 2V per cell.
  • Series to system voltage.
  • Tinned copper M8.
  • Links included.

3. Specifications

Item Parameter
Model KTR-GEL200
Rated voltage 2V
Rated capacity (10hr) 200Ah
Electrolyte gel (GEL)
Structure VRLA sealed
Float life 12~15 yr (25℃)
Max discharge 1000A (5 min)
Charge voltage 2.27~2.35 V/cell
Operating temp -20~50℃
Terminals tinned copper M8

4. Reference Prices

KTR-GEL200 2V200Ah gel battery (each): Reference USD 67~122 / pc (ref. CNY 480~880 at ~7.2)

KTR-GEL200 inter-cell link (with bolts): Reference USD 2.5~5 / pc (ref. CNY 18~35 at ~7.2)

Reference only; priced per cell. Racks, cabinets and install excluded. Exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • UPS backup power.
  • Telecom DC sites.
  • Off-grid solar storage.
  • DC switchgear control power.
  • Frequent deep-cycle storage.

6. Installation & Maintenance

Installation

  • Set rack/cabinet level.
  • Place cells by number.
  • Insulating separators between layers.
  • Torque series links.
  • Correct polarity.
  • String ends to UPS/rectifier.

Maintenance

  • Measure cell voltage & internal resistance.
  • No loose or oxidized joints.
  • Ambient 20~25℃.
  • Periodic equalize charge.
  • No bulge or leak.
  • Record discharge tests.

7. FAQ

  • Q: Gel vs AGM?
    A: AGM is cheaper and strong on high-current discharge, suiting short UPS backup; gel costs more but cycles deep, lives longer and tolerates heat, suiting frequent deep discharge and long storage. Use AGM for UPS backup, gel for solar and cycling.
  • Q: Why so many 2V cells in series?
    A: Each cell is only 2V, while a UPS DC bus is 192~480V, so hundreds are series-connected: voltage adds, capacity stays 200Ah. Series count sets voltage, parallel strings set capacity.
  • Q: Why hold 25℃?
    A: Lead-acid life is temperature-sensitive; every 10℃ rise roughly halves float life. Keep the battery room 20~25℃ with ventilation; heat accelerates water loss and grid corrosion.
  • Q: Do new cells need an initial charge?
    A: They arrive charged; check open-circuit voltage on receipt, and if stored over six months, refresh-charge before use. Run a charge/discharge capacity test before commissioning to confirm capacity.

8. Trend & Selection

Storage and backup move toward long-life, maintenance-free, deep-cycle cells; gel penetrates solar storage and telecom backup. Size series count by system voltage, capacity and parallel strings by backup time; choose gel over AGM for heat or deep-cycle duty, and add battery monitoring and temperature control.

9. Delivery & Service

KITOZER selects KTR-GEL200 cell count and parallel strings by UPS/storage voltage and backup time, providing rack layout and connection diagrams. Delivery includes cells, links, bolts and certificates. Warranty covers capacity testing and equalize-charge guidance.

10. Additional Notes

A common pitfall is loose or over-torqued link bolts. Loose joints raise resistance, heat and even arc; over-torque cracks the terminal. Tighten to the maker’s torque and re-torque three months after commissioning.

Another pitfall is mixing old and new cells or different batches. Series strings are limited by the weakest cell; mismatched internal resistance and capacity drag the whole string down. Replace in same-batch, same-model sets; never mix ages, and periodically measure internal resistance to find lagging cells.

Selection summary: 2V200Ah gel; deep-cycle long life; VRLA maintenance-free; series into strings; hold 25℃; same batch same model. The battery is the granary of backup power — tight joints, controlled temperature, regular internal-resistance checks keep the backup time holding when mains fails.

Contact Us

KITOZER brand (professional data center & low-voltage equipment supplier)
Tel/WeChat: +86 13922289957 | +86 18520668845
WHATSAPP: +86 19068534140
Web: lain.com.cn | gdlain.com

Scroll to Top