KITOZER Fire Alarm Control & Sensor Configuration

KITOZER Fire Alarm Control & Sensor Configuration Quotation List

2. Project Requirement Description

This system is an automatic fire alarm control system for data center/computer rooms, comprising an alarm host, various fire detection sensors, audible and visual alarms, manual alarm buttons, linkage modules, matching cables, and auxiliary materials. The requirements are as follows:

  • Real-time monitoring of fire hazards across the entire data center area
  • Precise detection of smoke and abnormal temperature conditions
  • Automatic alarm triggering, signal upload, and linkage with other fire-fighting equipment upon fire occurrence
  • Sensitive response with strong anti-interference capability, suitable for data center low-voltage environments
  • Fault self-diagnosis, historical recording, and zone management functions
  • Full compliance with national fire alarm standards (GB standards)

3. System Composition Introduction

The complete fire alarm control system comprises the following components:

  • Fire Alarm Controller (Main Host) — centralized control and monitoring
  • Photoelectric Smoke Detectors — comprehensive smoke detection coverage
  • Differential Fixed-Temperature Heat Detectors — temperature anomaly detection
  • Manual Fire Alarm Buttons — manual alarm initiation at key locations
  • Audible & Visual Alarm Devices — sound and light alerting
  • Input Modules — signal feedback collection from external devices
  • Output Linkage Modules — control of external fire-fighting equipment
  • Detector Bases — mounting and wiring bases for detectors
  • Fire Alarm Terminal Boxes — wiring distribution and termination
  • Fire-rated Dedicated Cables — bus communication wiring
  • Wiring Terminals & Auxiliary Materials — installation accessories

The system adopts a bus-type architecture with zoned management of various protected areas within the data center. Detectors are connected to the main host via bus wiring, and the system supports linkage with gas fire suppression systems and emergency lighting systems.

4. Core Product Specifications & Parameters

Item Specification
Fire Alarm Controller (Main Host) AC220V main power + DC24V backup battery, bus loops ≥8, supports zone programming, fault self-diagnosis, historical record storage
Photoelectric Smoke Detector Photoelectric type, working voltage DC24V, alarm threshold compliant with national standards, response time ≤3s
Differential Fixed-Temperature Heat Detector Differential fixed-temperature type, operating temperature 57°C, suitable for high-temperature areas in data centers
Audible & Visual Alarm Device DC24V, sound intensity ≥85dB, flashing light, indoor wall-mounted type
System Bus Two-wire bus with non-polarized wiring, maximum transmission distance per loop ≥1000m
Operating Environment Temperature: -10°C to 60°C, humidity ≤95%, electromagnetic interference resistant, suitable for mixed strong/weak current data center environments

5. Core Functions & Features of Products

  • Comprehensive Zone Monitoring: Combined smoke and heat detection provides full coverage of fire hazards across different data center areas with no blind spots
  • Intelligent Alarm: Zone-specific fire location display, automatic fault indication, queryable historical alarm records for traceability
  • Linkage Control: Seamless integration with gas fire suppression systems, emergency lighting, ventilation equipment, and access control systems for integrated fire-fighting linkage
  • High Stability & Reliability: Bus-type architecture with strong anti-interference capability, suitable for complex electromagnetic environments in data centers, ensuring long-term stable operation
  • User-Friendly Operation: Chinese display interface with menu-driven operation, offering a friendly human-machine interface that is easy for duty personnel to master
  • Dual Power Supply: Main power + backup battery dual-supply design, ensuring continued normal operation during power outages

6. Core Advantages of The Solution

  • Standard Compliance: The entire system meets national fire alarm standards (GB standards), ensuring full regulatory compliance for data center fire safety
  • Comprehensive Detection Coverage: Combined smoke and heat detection strategy effectively covers all high-risk areas within the data center, including server rooms, power distribution areas, and UPS zones
  • Fast Response: Smoke detectors achieve response times ≤3 seconds, enabling rapid fire detection and early warning
  • Scalable Architecture: Bus-type design with 8+ loops allows easy system expansion as data center facilities grow
  • Dual-Power Reliability: AC + DC backup power ensures uninterrupted system operation even during mains power failure
  • Complete Fire-Fighting Linkage: Pre-configured linkage with gas suppression and emergency lighting systems delivers integrated fire protection
  • project-confirmed Quality: All products are manufactured in-house under strict quality control, ensuring consistent performance and reliability

7. Manufacturer Strength Introduction

KITOZER is the proprietary brand of Guangzhou Lai’an Intelligent System Development Co., Ltd., a professional manufacturer of intelligent systems and industrial equipment. The company also operates under Guangdong Lai’an Intelligent Data Center Equipment Co., Ltd. for data center-specific product lines.

  • Established in 2002, with over 20 years of manufacturing experience
  • Certified to ISO 9001 (Quality Management), ISO 14001 (Environmental Management), and ISO 45001 (Occupational Health & Safety)
  • Recognized as a National High-Tech Enterprise
  • Project-confirmed manufacturing capabilities with complete quality inspection procedures before shipment
  • Strong R&D team dedicated to continuous product innovation and improvement
  • Comprehensive production facilities located in Guangzhou, China

8. Detailed Quotation Table

No. Product Name Model & Spec Technical Parameter Qty Unit Unit Price (USD) Total Price (USD) Brand Remark
1 Fire Alarm Controller (Linkage Type) KT-FJK-08 8-loop bus, DC24V backup battery, Chinese LCD display 2 Unit 1132.16 2264.32 KITOZER Data center fire main control host
2 Photoelectric Smoke Fire Detector KT-GY-80 Bus type, DC24V, indoor data center dedicated 96 Pcs 21.31 2045.76 KITOZER Full-area smoke detection
3 Differential Fixed-Temperature Fire Detector KT-WD-82 Bus type, operating temperature 57°C, for high-temperature zones 48 Pcs 19.09 916.32 KITOZER Dedicated for power distribution cabinets & UPS areas
4 Detector Dedicated Base KT-DZ-84 Mating base for smoke/heat detectors, bus wiring base 144 Pcs 5.77 830.88 KITOZER 1 base per detector
5 Manual Fire Alarm Button KT-SB-86 Wall-mounted, bus type, local manual alarm 24 Pcs 23.98 575.52 KITOZER Installed at passages & zone entrances
6 Fire Audible & Visual Alarm Device KT-SG-88 DC24V, sound + light alarm, indoor wall-mounted 18 Unit 31.97 575.46 KITOZER Fire sound & light indication
7 Single-Channel Input Module KT-SR-90 Bus module, collects equipment feedback signals 36 Pcs 17.32 623.52 KITOZER For signal acquisition
8 Single-Channel Output Linkage Module KT-SC-92 Bus module, controls external fire-fighting equipment 30 Pcs 20.42 612.60 KITOZER Links fire suppression & lighting systems
9 Fire Alarm Terminal Box KT-DX-94 Wall-mounted, low-voltage wiring distribution box 12 Pcs 30.19 362.28 KITOZER Bus line distribution & termination
10 Fire Two-Wire Bus Cable KT-XZ-96 2×1.5mm² shielded fire cable, 100m/roll 26 Roll 51.06 1327.56 KITOZER Detector & module wiring
11 Low-Voltage Wiring Cable Tray KT-XC-98 Flame-retardant PVC cable tray, 20×10mm, 2m/piece 120 Pcs 4.00 480.00 KITOZER Cable organization & protection
12 Host Backup Battery KT-DC-12V 12V/24Ah, alarm host backup power supply 4 Pcs 68.82 275.28 KITOZER For power outage backup
13 Wiring Terminals & Auxiliary Materials KT-FC-100 Wiring terminals, cable ties, waterproof connectors and complete auxiliary materials 1 Batch 186.47 186.47 KITOZER Installation supporting materials

Total Quotation Price: USD 11075.97

*Note: Unit prices are converted from CNY to USD at the fixed rate of 1 USD = 6.7570 CNY.*

9. Quotation Terms & Conditions

1. Currency: All prices are quoted in US Dollars (USD).

2. Incoterms: EXW Guangzhou, China (other terms negotiable upon request).

3. Taxes: The quoted price excludes taxes. Value-added tax (VAT) special invoice requires an additional 10% surcharge; VAT general invoice requires an additional 3% surcharge.

4. Shipping & Freight: Freight costs are not included in the quotation and will be paid by the buyer (freight collect).

5. Payment Terms: 30% deposit upon order confirmation and 70% balance before shipment (negotiable for long-term partners).

6. Lead Time: 15-30 working days depending on product configuration and order quantity.

7. Quotation Validity: This quotation remains valid for 30 days from the date of issue.

8. Packing: Standard export packaging is included. Special packing requirements may incur additional charges.

9. Inspection: All products undergo complete quality inspection before shipment.

10. After-sales Service Description

KITOZER is committed to providing comprehensive after-sales support for all our products:

  • Warranty: 12-24 months warranty period depending on specific product category, covering manufacturing defects and non-human-induced failures
  • Lifetime Technical Support: Free technical consultation and guidance for the lifetime of the products
  • Spare Parts Availability: Long-term supply of genuine spare parts to ensure continued system operation
  • Remote Troubleshooting: Technical team available for remote diagnosis and troubleshooting assistance
  • On-Site Service: On-site installation guidance, commissioning support, and maintenance services available upon request (travel and labor costs quoted separately)
  • Documentation: Complete user manuals, wiring diagrams, and commissioning guides provided with every shipment

11. Contact & Order Information

To place an order or request additional information, please contact the KITOZER sales team through the following channels:

  • Official Website: www.gdlain.com
  • Manufacturer: Guangzhou Lai’an Intelligent System Development Co., Ltd. / Guangdong Lai’an Intelligent Data Center Equipment Co., Ltd.
  • Address: Chaotian Industrial Park, Zhongrun Industrial Park, No. 5 Huashan Road, Shilou Town, Panyu District, Guangzhou City, China
  • Contact Person: Mr. Zhou
  • Phone / WeChat: +86 139 2228 9957

All inquiries will receive a response within 24 hours. Bulk order discounts and OEM/ODM customization services are available upon request.

12. SEO Keywords & Tags

KITOZER quotation, fire alarm control system price list, fire alarm control and sensor configuration quotation, data center fire alarm system cost, fire alarm controller factory price, photoelectric smoke detector price, heat detector quotation, fire alarm linkage module price, KITOZER fire alarm system wholesale, Guangzhou fire alarm system manufacturer, computer room fire protection system quotation, fire alarm system price USD, industrial fire alarm equipment supplier, KITOZER fire alarm products price list

Shopping Cart