The KITOZER 1/4 inch flexible RF jumper connects the top of a rigid feeder run to the antenna or RRU, and connects rack-mounted RRUs to indoor DAS distribution panels. Because rigid feeder cannot bend around equipment corners, short flexible jumpers provide the final connection with controlled loss and durability. KITOZER jumpers use a braided copper outer conductor for flexibility, a foam PE dielectric, and factory-assembled 4.3-10 or N male connectors. They are available in standard lengths from 0.5m to 10m, with waterproof heat-shrink boots for outdoor use. Low PIM construction ensures clean multi-carrier operation on cell towers.
Table of Contents
ToggleTechnical Specifications
Cable type is 1/4 inch flexible corrugated, outer diameter 6.0mm. Nominal attenuation at 2GHz is 0.25dB/m, at 3.5GHz is 0.35dB/m. Characteristic impedance 50 ohm. Velocity factor 80 percent. Connectors are 4.3-10 male to 4.3-10 male, or N male to N male, with right-angle options. PIM is better than -155dBc with two 43dBm carriers. Operating temperature -40C to +70C. Jacket is black LSZH for indoor or UV-stabilized PE for outdoor. Standard lengths: 0.5m, 1m, 2m, 3m, 5m, 10m. Bend radius 25mm. Each jumper ships with a PIM test report.
Application Scenarios
RF jumpers connect the feeder end to the antenna at the top of the tower, connect the feeder bottom to the RRU in the cabinet, and link rack-mounted RRUs to DAS splitters and combiners in equipment rooms. They are also used for test bench connections, temporary coverage boosters, and tunnel end connections. Outdoor jumpers use the weatherproof boot option; indoor jumpers use LSZH jacket for plenum safety.
Advantages and Features
Factory-assembled connectors eliminate field-termination errors that are a leading cause of high PIM on towers. The braided outer conductor survives repeated flexing during installation. Low loss keeps the final connection to the antenna below 0.5dB even over 2m length. KITOZER jumpers are pre-tested for PIM and VSWR, with test reports shipped with each batch. The waterproof boot provides years of outdoor service. Standard lengths reduce spare parts inventory compared with custom cable runs.
Installation and Maintenance Recommendations
Avoid sharp bends below the 25mm minimum radius. Torque 4.3-10 connectors to 5N and N connectors to 25N. Seal outdoor connectors with self-amalgamating tape. During commissioning, measure through-loss and PIM per jumper. Inspect outdoor jumpers during tower climbs; replace any jumper showing cracked boot or bent connector. Keep a box of standard-length jumpers at the regional depot for fast swap.
Quality and Reliability
KITOZER factory tests every unit across full temperature and power sweeps before shipment. Each product passes RF calibration, intermodulation, and environmental stress screening. The enclosure uses corrosion-resistant materials with a UV-stable finish, suitable for coastal, industrial, and desert atmospheres. KITOZER provides a 5-year warranty and 24 hour spare parts logistics from regional warehouses. Every unit ships with a test report documenting per-channel power, return loss, and noise figure. On-site technical support is available via phone and remote diagnostics to resolve issues before dispatching a truck. Firmware updates are delivered remotely with rollback protection, and spare parts are cross-compatible across the product family to simplify inventory management.
Price
From $25 per jumper. Contact +86 13922289957 for jumper pricing.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com