KITOZER KTR-PDU8C Rack PDU (8xC13 / 16A / Surge)

Brand: KITOZER Series: KTR-PDU8C Category: Rack Accessory / PDU

8xC1316A input1U horizontalsurge protectedKTR-PDU8C

1. Overview

The KITOZER KTR-PDU8C is a rack-mounted power distribution unit that centrally delivers power to servers, switches, routers and storage in a cabinet. Input 16 A (one 16 A industrial plug or hardwired); output eight C13 (10 A) outlets; 1U horizontal mounting; aluminum housing; master switch and surge protection. Versus a generic power strip, KTR-PDU8C is rack-specific: 19-inch standard mounting, built-in surge protection, tidy cabling, daisy-chainable, and clear power allocation.

KTR-PDU8C rated 4000 W (220 V / 16 A), eight C13 outlets with widened spacing (so C14 adapters and transformers do not block adjacent sockets). Internal surge module (nominal discharge 5 kA, max 10 kA, limiting voltage up to 1.5 kV), with a surge indicator window (green normal / red failed). Master switch with light (auto-trip on overload). Input cord 1.8 m, 16 A C20 plug or industrial connector optional. Optional current/voltage meter (shows total current, power, kWh) and remote monitoring (dry-contact alarm).

Typical uses: data-center cabinet server power; low-voltage cabinet (CCTV, network, security) distribution; lab and test-bench power; meeting-room AV; edge computing nodes. KTR-PDU8C replaces generic strips, solving messy outlets, no surge protection and no overload protection; one PDU serves eight devices with tidy cabling and fast fault localization.

2. Key Features

8xC13 output

  • Eight C13 outlets.
  • Widened 45 mm spacing.
  • Fits C14 plugs.
  • Total 4000 W.

Surge protection

  • Internal surge module.
  • 5 kA nominal / 10 kA max.
  • Limiting voltage ≤1.5 kV.
  • Green/red indicator.

Rack mount

  • 1U horizontal aluminum.
  • 19-inch standard.
  • Master switch with light.
  • 16 A C20 input.

Smart options

  • Current/voltage meter optional.
  • Dry-contact alarm optional.
  • Remote SNMP optional.
  • Daisy-chainable.

3. Specifications

Item Parameter
Model KTR-PDU8C
Input 16 A C20 plug (1.8 m cord) or hardwired
Output 8x C13 outlets
Rated power 4000 W (220 V/16 A)
Surge 5 kA nominal / 10 kA max, limiting ≤1.5 kV
Master switch 16 A lit, auto-trip
Housing aluminum, 1U horizontal
Mounting 19-inch rack square holes
Outlet spacing 45 mm widened
Operating temp 0~+40 C
Protection IP20 indoor
Dimensions about 483x44x44 mm

4. Reference Prices

KTR-PDU8C basic (8xC13/16A/surge): Ref. USD 39~63 / pc (CNY 280~450 at 7.2)

KTR-PDU8C metered (current/voltage): Ref. USD 63~94 / pc (CNY 450~680 at 7.2)

KTR-PDU8C smart (SNMP remote): Ref. USD 125~208 / pc (CNY 900~1500 at 7.2)

16 A C20 input cord (2 m): Ref. USD 8~14 / pc (CNY 60~100 at 7.2)

C13 to C14 cord (1.8 m, 5 pcs): Ref. USD 11~21 / pack (CNY 80~150 at 7.2)

Reference only; exchange: 1 USD ~ 7.2 CNY (Oct 2026).

5. Applications

  • Data-center cabinet server power.
  • Low-voltage cabinet network/security.
  • Lab and test bench.
  • Meeting-room AV.
  • Edge computing node.

6. Installation & Maintenance

Installation

  • Mount KTR-PDU8C on the rack rear or side 1U position with square-hole screws.
  • Connect input to UPS output or 16 A wall outlet (do not use a 10 A socket).
  • Set master switch to OFF.
  • Insert each device C14 plug one by one.
  • Confirm total power under 4000 W (eight servers at 300 W each = 2400 W, leave margin).
  • Turn on master switch; surge indicator should be green.
  • Metered version shows total current (under 13 A, leave 20 percent).
  • Tidy cords with a cable manager; keep 30 mm from network cables.

Maintenance

  • Check the surge indicator monthly (replace module if red).
  • Quarterly verify total current under 80 percent rated.
  • Yearly check input and output plugs for heat (IR thermometer).
  • After overload trip, reduce load before resetting; never force it.
  • Do not daisy-chain a power strip off the PDU.
  • Clean the housing dry; never use a wet cloth.

7. FAQ

  • Q:PDU vs generic strip?
    A:Generic strips are consumer grade (10 A / 2500 W), mediocre flame retardance, no surge protection, tight socket spacing, thin 0.75 mm2 wire. PDU (KTR-PDU8C) is industrial: 16 A / 4000 W, 1.5 mm2 wire, aluminum flame-retardant housing, surge protected, rack-standard mounting, 45 mm outlet spacing. Data centers and critical rooms must use PDU, not consumer strips.
  • Q:How many servers per 8xC13?
    A:By rated server power: a 1U server is about 300 W; eight = 2400 W (10.9 A), well under 4000 W (16 A). But a GPU server draws 800 to 1000 W, so eight outlets serve only 3 to 4. Size by actual load; keep one PDU under 80 percent (3200 W) for safety. GPU racks need a PDU per server or smart PDU (per-outlet monitoring).
  • Q:Surge window turned red?
    A:A red surge window means the internal MOV or gas tube has degraded (absorbed surges and reached end of life). The PDU still powers loads but loses surge protection. Replace the pluggable surge module promptly (with master switch off, never live). Check after each storm season; the surge module is consumable, replace every 3 to 5 years.
  • Q:Do I need a smart PDU?
    A:Basic PDU (master + surge) suits small rooms and fixed-power equipment. Smart PDU (per-outlet current / remote switching) suits: many servers, variable load, remote reboot (no on-site visit for hung devices), per-outlet billing (IDC rack rental). Typical enterprise rooms use metered PDU; IDC and large data centers use smart.

8. Trend & Selection

PDUs are moving toward smart (per-outlet metering, remote switching, SNMP), three-phase high current (32 A / 63 A) and DC (48 V HVDC). IoT enables cloud-based rack-power visibility, linked to UPS and cooling. Outlets move from C13 to C19 (16 A) and MeeTec (direct connect) for high-power GPU servers. Green data centers push metering accuracy from 1 A to 0.1 A to support PUE accounting.

9. Delivery & Service

KITOZER sizes KTR-PDU8C by cabinet total load and outlet count, providing installation drawings and a power budget table. Delivery includes PDU, mounting screws, input cord and certificate. Warranty covers surge-module replacement and meter calibration.

10. Additional Notes

A common pitfall is plugging a 16 A input into a 10 A wall socket. A C20 plug cannot enter a 10 A socket, but users force a converter, which overheats and risks fire. The PDU input must go to a 16 A wall socket or a 16 A UPS output terminal; never use an adapter.

Another pitfall is daisy-chaining a strip off the PDU. Daisy-chaining bypasses the PDU surge and overload protection (the strip has none), and thin daisy-chain wires cause contact-resistance heating. One PDU serves eight devices; if more outlets are needed, add another PDU fed from the UPS, never a chain.

Selection summary: 8xC13, 16 A / 4000 W, surge protected, 1U horizontal. PDU is the standard cabinet distribution item; the keys are 1.5 mm2 input wire, non-blocking outlet spacing, 20 percent power margin, and no strip daisy-chaining.

Additional tip: PDU mounting location matters. Horizontal rear mount (beside the UPS) shortens the input cord, but C13 outlets face backward, requiring server cords to loop. Side mount on the post puts outlets forward with short device cords, but occupies post space. Network cabinets prefer side mount (short cords); server cabinets prefer rear mount (short input cord).