Table of Contents
ToggleProduct Overview
The KITOZER Rackmount UPS 2kVA delivers 2000VA and 1800W of online double-conversion power in a compact 2U chassis that converts to tower form factor when needed. Designed for small server rooms, network core switches, storage arrays, and mid-size security systems, this unit provides clean regulated power and instant battery backup during utility failures. The convertible rack-to-tower design gives integrators flexibility when deploying in different cabinet or closet environments, and the external battery port allows extended runtime for installations requiring 30 minutes or more of autonomy.
The KITOZER 2kVA uses transformer-less high-frequency topology to achieve 91 percent online efficiency and 97 percent eco efficiency, reducing heat and electricity cost. The front panel color LCD rotates for rack or tower orientation and shows real-time input, output, load, battery, temperature, and event history. Up to four external battery packs can be paralleled to achieve multi-hour backup. The unit supports AS400 dry contact for legacy server shutdown signaling.
Built for 24/7 IT operation, the KITOZER 2kVA includes input power factor correction greater than 0.99 and total harmonic distortion less than 5 percent. The wide input range from 110 to 300VAC allows deployment in regions with weak or unstable grid voltage. The unit is CE certified and complies with IEC 62040 standards. Intelligent battery management monitors cell voltage, charge current, and temperature to maximize battery life and predict end-of-life.
Technical Specifications
Input range 110 to 300VAC full load, frequency 40 to 70Hz auto-sensing, input PF greater than 0.99. Output 230VAC plus or minus 2 percent, power factor 0.9, online efficiency 91 percent, eco efficiency 97 percent. Six C13 and one C19 output sockets. Standard internal battery gives 8 to 12 minutes at half load; up to four external battery packs can be paralleled to achieve 1 to 4 hours of backup. Communication options include USB, RS232, dry-contact, and optional SNMP or Modbus card.
LCD displays real-time input, output, load, battery, and temperature. Overload rating 110 percent for 10 minutes, 125 percent for 30 seconds. Dimensions 438 by 440 by 86 mm, weight 18 kg. Operating temperature 0 to 40 degrees Celsius. Noise level less than 45 dB(A). Event log stores 512 records. Three-year standard warranty. Color LCD with backlight.
Application Scenarios
Typical deployments include SMB server rooms with one or two rack servers, VoIP phone systems, core routers and firewalls, NVR and CCTV storage, industrial workstations, laboratory instruments, and hotel reservation terminals. The long backup option is frequently chosen for sites where a generator is not installed and orderly shutdown must be guaranteed. Rack-to-tower conversion is useful in small workshops where floor standing is preferred over cabinet mounting.
Additional applications include retail backbone networks, bank branch servers, university departmental labs, and small medical imaging equipment. The wide 110 to 300V input window allows deployment in regions with weak grid voltage without frequent battery switching. The pure sine-wave output supports active PFC power supplies in modern blade servers and high-end storage. The unit is also suitable for edge computing nodes, retail kiosks, and small manufacturing work cells.
Key Advantages
Wide 110 to 300V input window lets the UPS ride through deep sags without draining batteries. Online double conversion isolates the load from virtually all utility disturbances including surges, sags, noise, and frequency variation. Intelligent battery management predicts end-of-life and compensates charge voltage for temperature. Hot-swap battery packs allow service without downtime.
Parallel external battery packs scale runtime linearly. The optional SNMP card integrates with DCIM, building management, and NMS platforms for remote monitoring and alarm email. Compact 2U design and tower feet make the unit adaptable to varied site layouts. AS400 dry contact supports legacy server shutdown signaling. Three-year standard warranty. CE certified for global deployment.
Installation and Maintenance Advice
Use the included rail kit for rack mounting or the tower feet for floor placement. Provide at least 1U clearance for airflow and keep the front unobstructed. Connect external battery packs with the matching KITOZER cables and observe polarity. Do not mix old and new battery packs.
Perform a full discharge test every 6 months to verify runtime. Recharge batteries for 8 hours after installation or replacement. Keep ambient at 20 to 25 degrees Celsius to maximize battery life to 5 years. Update UPS firmware when new releases are available from KITOZER support. Keep the event log exported before firmware upgrades. Download KITOZER PowerShut software for graceful server shutdown.
Price
From $690 per unit. External battery packs, SNMP card, and extended warranty quoted separately. Contact KITOZER for long backup configuration quote.
Guangzhou Laian Intelligent System Development Co., Ltd. | Tel/WeChat: +86 13922289957 / +86 18520668845 | WhatsApp: +86 19068534140 | www.gdlain.com