KITOZER Rackmount UPS 3kVA 2U Online Double Conversion

Product Overview

The KITOZER Rackmount UPS 3kVA is a high-density 2U online UPS delivering 3000VA and 2700W for IT racks, network core infrastructure, and edge data centers. With power factor 0.9 and a true double-conversion topology, it powers modern servers with active PFC power supplies without risk of overload. The compact 2U height leaves valuable rack space for servers and switches, while the internal battery set provides enough autonomy for graceful shutdown and generator takeover. A color LCD on the front panel rotates for rack or tower orientation, and hot-swappable battery packs simplify field service.

Built for 24/7 operation, the KITOZER 3kVA features input power factor correction greater than 0.99 and total harmonic distortion less than 5 percent, helping the site comply with IEEE 519 requirements. The unit supports parallel operation for up to 3 units with an optional parallel kit, enabling N+1 redundancy without an external STS. The built-in energy meter shows kWh consumed and supports sustainability reporting.

The KITOZER 3kVA is CE certified and complies with IEC 62040 safety and EMC standards. The transformer-less high-frequency design reduces size, weight, and heat while maintaining high reliability. Intelligent battery management performs periodic self-tests, monitors cell voltage and temperature, and predicts end-of-life. The unit is designed for IT environments where rack space is at a premium and downtime is unacceptable.

Technical Specifications

Input 200 to 240VAC nominal, range 110 to 300VAC, frequency 40 to 70Hz. Output 200, 208, 220, 230, or 240VAC selectable, power factor 0.9, online efficiency 92 percent, eco efficiency 97.5 percent. Output sockets include 8 C13 and 2 C19. Typical internal runtime 5 to 8 minutes at full load, 15 to 25 minutes at half load. Up to 4 external battery packs extend runtime to hours.

Communications: USB, RS232, AS400 dry contact, optional SNMP or Modbus TCP card. Parallel capability for up to 3 units. Dimensions 438 by 620 by 86 mm, weight 28 kg. Event log stores 512 records. Operating temperature 0 to 40 degrees Celsius. Noise level less than 50 dB(A). Color LCD with backlight. Three-year standard warranty.

Application Scenarios

Deploy this UPS in medium IT closets, retail data rooms, branch offices of banks, hospital imaging suites, industrial SCADA control rooms, and distributed edge computing nodes. It is well suited to high-density rack servers, blade server enclosures, storage area networks, and core routing equipment. The parallel option allows N+1 redundancy for critical applications that cannot tolerate single-UPS failure.

Additional use cases include university server labs, government back-office systems, media editing workstations, and security operations centers. Long battery packs are selected when generator start-up time is long or when orderly shutdown of virtualized hosts must be supported. The 2U compact size makes it ideal for edge data centers with limited rack space. The unit is also suitable for retail backbone networks, bank branch servers, and small manufacturing work cells.

Key Advantages

Power factor 0.9 means 2700W real output from a 3kVA frame, matching modern server power supplies better than older 0.7 PF units. Wide input voltage window reduces battery cycling. Online double conversion filters surges, sags, and noise. Hot-swappable batteries permit replacement without load interruption.

Parallel N+1 option provides redundancy without needing a separate STS. Rotating color LCD reads correctly in any orientation. Built-in energy meter shows kWh consumed and supports sustainability reporting. SNMP or Modbus TCP integration fits existing DCIM and NMS tools. Low THDi less than 5 percent protects upstream distribution. Three-year standard warranty. CE certified for global deployment.

Installation and Maintenance Advice

Use heavy-duty rails rated for the 28 kg weight. Provide dedicated 16A circuit and hardwired input for full load. Keep rack front and rear doors open or use rack fans to avoid heat buildup. Do not daisy-chain UPS units. For parallel N+1, use the KITOZER parallel cable kit and ensure identical firmware.

Inspect batteries every 6 months; replace when runtime drops below 70 percent of nameplate. Keep ambient temperature below 25 degrees Celsius. Run a scheduled self-test monthly. Save the event log before firmware upgrades. Keep spare battery pack on site for fast replacement. Download KITOZER PowerShut software for graceful server shutdown during extended outages.

Price

From $1,050 per unit. Parallel kit, external battery packs, SNMP card, and extended warranty quoted separately.